Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cadmium Compounds”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Practical limit of the accuracy of radiometric measurements using HgCdTe detectors.

The spectral responsivity of HgCdTe detectors operating in the thermal infrared region was observed to drift slowly with time. The characteristics of the drift were investigated and were shown to have a different origin from the drifts previously reported by one of the authors. Those drifts were caused by a thin film of water ice depositing on the active area of the cold detector. The source of the new drift is far more serious because it is fundamental, making the acquisition of accurate radiometric measurements with these detectors very difficult. It is demonstrated that the source of the new drift is the nonlinearity in the response of the HgCdTe detectors, coupled with the fluctuations of the irradiance reaching them. These fluctuations are due to variations in the thermal background caused by changes in the temperature of objects in the field of view of the detectors. This phenomenon is expected to provide a practical limit to the accuracy of radiometric measurements using not only HgCdTe detectors but also other detectors whose linearity is a function of the thermal background.

Cadmium Compounds↗

Increased micronucleus frequency after oral administration of cadmium in dogs.

Cadmium (Cd) is a toxic heavy metal that has been classified as a human carcinogen by the International Agency for Research on Cancer. The genotoxic effects of cadmium oxide (CdO) were investigated in cultured dog lymphocytes after a short-term oral CdO administration by the micronucleus (MN) test. The dogs were given 10 mg CdO/kg body weight per day for 3 and 28 d, respectively group I (n = 7) and group II (n = 6). Blood samples were collected at the beginning of feeding and at 4 and 29 d after Cd administration and cultured for 72 h. Whereas no significant increase in the MN frequency in group I was observed (p = 0.398), a significant MN induction with CdO was found in group II (p = 0.028) when compared with initial MN frequencies of dogs in both groups. Our results suggest that CdO might be directly and/or indirectly genotoxic after a monthly oral administration of CdO in dogs.

Administration, Oral↗

Fluorescence quenching of bovine serum albumin.

The fluorescence emission spectra and 3D fluorescence spectra of bovine serum albumin (BSA) in cetyltrimethylammonium bromide (CTAB) reversed micelles were affected by the microenvironment. Blue shifts of the fluorescence emission peaks were found when BSA was present in CTAB reversed micelles. The fluorescence intensity changed with the water content. Similar changes in the peak regions of the 3D fluorescence spectra were also observed. CdS nanoparticles prepared in CTAB reversed micelles quenched the fluorescence of BSA significantly. The fluorescence of BSA was more effectively quenched by negative CdS nanoparticles than by positive or neutral CdS ones. The quenching degree increased linearly with increasing the concentration of negative CdS nanoparticles over the range of 5.0 x 10(-6) - 3.0 x 10(-5) mol L(-1). The quenching mechanism is discussed and the quenching constant is 1.32 x 10(4) L mol(-1).

Algorithms↗

Toluene/ter-butanol mixed solvent for the selective extraction of Cr(VI) from divalent heavy metals.

A solvent-extraction system comprising toluene/ter-butanol (ter-BuOH) mixed solvent as the organic phase was developed to selectively extract Cr(VI) from acidic chloride media in the presence of divalent metals, namely Cd(II), Co(II), Cu(II), Ni(II) and Zn(II) under 5 M CaCl2 salting-out conditions. Chromium(VI) was selectively extracted as a solvated ion-pair of [ter-BuOH2+ x CrO3Cl-] at ter-BuOH mole fractions of between 0.1 and 0.6 (9.0-57.2% in volume). Divalent metals were extracted at ter-BuOH mole fraction over 0.6 with extraction percents of Co (< 20%), Cu (< 15%), Ni (< 10%) and Zn (< 20%). The concentrations of Ca2+, water and ter-BuOH in the organic phase and ter-BuOH in the aqueous phase were determined to find out the effects on the extraction of Cr(VI). The chemical species of Cr(VI) in acidic chloride media containing 5 M CaCl2 and 0.1 M HCl was confirmed to be the CrO3Cl- species. The effects of the acid, salt concentrations in the aqueous phase and the solvent composition of a mixed organic solvent on the extraction of Cr(VI) were evaluated. Based on the above studies, the extraction mechanism was elucidated and the optimum extraction conditions were determined.

Cadmium Compounds↗

Separation study of cadmium as CdI4(2-) through a bulk liquid membrane containing ketoconazole and oleic acid.

A chloroform membrane system containing a given mixture of ketoconazole and oleic acid was applied for the uphill transport of Cd2+ ions as CdI42-. In an HCl medium the ligand could form a stable ion-pair with CdI4(2-), which was readily extractable in the membrane phase. A weak basic solution (pH 8) was used as a suitable stripping medium for the quantitative transport of cadmium across the liquid membrane after 120 min. The selectivity and efficiency of Cd2+ transport from an aqueous solution containing other cations, such as Co2+, Cr3+, Ni2+, Fe2+, Mn2+, Pd2+ and Zn2+ ions, were investigated. It was found that none of these cations interfered with Cd2+ transport.

Cadmium↗

Blood mercury in workers exposed to the preparation of mercury cadmium telluride layers on cadmium telluride base.

Study was conducted in a group of 32 persons engaged in liquid phase epitaxial growth of mercury cadmium telluride (MCT) layers for nearly 11 years. Airborne mercury concentrations in work environment have been exceeding the threshold limit value of 0.05 mg/m3 recommended by ACGIHD. Hg concentration in workplace during peak working hours remained between 0.04-0.08 mg/m3. Findings were compared with 32 unexposed referents. Mercury value was estimated 1.60 +/- 0.20 (mean +/- SD) in control, and in Phase I and II, 10.72 +/- 1.34 ng Hg/ml and 8.08 +/- 1.15 ng Hg/ml of blood respectively. Results indicate a fall in blood mercury level during the second phase of study. But the values did not return to normal even after a gap of 3 months. An individual who met with a mercury accident showed 226 ng Hg/ml of blood which decreased to 25 ng/ml after 3 months. It is inferred from the present study that Hg level has increased significantly in MCT workers during working period, and also in non-working period, the values were higher than controls.

Accidents, Occupational↗

Electrogenerated chemiluminescence of CdSe quantum dots dispersed in aqueous solution.

Electrogenerated chemiluminescence (ECL) of CdSe quantum dots (QDs) dispersed in aqueous solution was studied with bare electrode. The ECL emission was observed at -1.4 V vs. Ag/AgCl and the ECL spectrum peak is similar to that of the defect photoluminescence (PL) spectrum, indicating the surface defects played a critical role in the emission process. The experiment results suggested that dissolved oxygen had a great effect on the ECL intensity. Other influence factors including the electrochemical parameters and QDs concentration were investigated in detail. As an application of the CdSe QDs ECL, the pyrogallol (1, 2, 3-trihydroxybenzene) was detected in aqueous solution. Under the optimal conditions, a linear relationship between ECL intensity and pyrogallol concentration was obtained in the range from 4.0 x 10(-7) to 2.0 x 10(-5) M with a correlation coefficient of 0.9904 and the limit of detection was 6.6 x 10(-8) M (S/N = 3). A possible mechanism about ECL of QDs was also discussed.

Biosensing Techniques↗

[Computerized single probe system using a cadmium telluride detector].

Using cadmium telluride (CdTe) as a detector, we assembled a computerized single probe system. The size of the CdTe used is 16 mm in diameter and 2 mm in thickness. Two types of the straight bore collimators of 16 mm in diameter were prepared. One is 16 mm in length (long type) and the other is 5 mm in length (short type). The response curves of the long and short type collimators to 57Co in water showed that the points at 10% of maximum counts were 4 cm and 3 cm in depth along the center axis. The data were accumulated by using a commercialized single cardiac probe system (OMNISCOPE) and processed by itself or transferred to the microcomputer (LSI-11/23) for further analysis. Twenty percent count loss occurred at 100 000 cps with an integral discriminator setting. This system was applied for cerebrospinal fluid (CSF) shunt flow evaluation and measurement of left ventricular ejection fraction (LVEF). Measurement of CSF shunt flow has been able to do in any patient's positioning. In 21 patients with various heart diseases, LVEFs obtained by CdTe detector were compared with those obtained by scintillation detector. There was good correlation between the LVEFs obtained by these two detectors: correlation coefficient (r)=0.939.

Cadmium↗

The translation elongation factor eEF1B plays a role in the oxidative stress response pathway.

The multi-subunit guanine nucleotide exchange factor eEF1B for Saccharomyces cerevisiae Translation Elongation Factor 1A (eEF1A) has catalytic (eEF1Balpha) and noncatalytic (eEF1Bgamma) subunits. Deletion of the two nonessential genes encoding eEF1Bgamma has no dramatic effects on total protein synthesis or translational fidelity. Instead, loss of each gene gives resistance to oxidative stress, and loss of both is additive. The level of stress resistance is similar to overexpression of the Yap1p stress transcription factor and is dependent on the presence of the YAP1gene. Cells lacking the catalytic eEF1Balpha subunit show even greater resistance to CdSO(4), with or without eEF1Bgamma present. Thus, the loss of guanine nucleotide exchange activity promotes the resistance. As nucleotide exchange is a critical regulator of most G-proteins, these results indicate a new mechanism in the growing list of examples of post-transcriptional responses to cellular stress.

Cadmium Compounds↗

The electrical properties of auditory hair cells in the frog amphibian papilla.

The amphibian papilla (AP) is the principal auditory organ of the frog. Anatomical and neurophysiological evidence suggests that this hearing organ utilizes both mechanical and electrical (hair cell-based) frequency tuning mechanisms, yet relatively little is known about the electrophysiology of AP hair cells. Using the whole-cell patch-clamp technique, we have investigated the electrical properties and ionic currents of isolated hair cells along the rostrocaudal axis of the AP. Electrical resonances were observed in the voltage response of hair cells harvested from the rostral and medial, but not caudal, regions of the AP. Two ionic currents, ICa and IK(Ca), were observed in every hair cell; however, their amplitudes varied substantially along the epithelium. Only rostral hair cells exhibited an inactivating potassium current (IA), whereas an inwardly rectifying potassium current (IK1) was identified only in caudal AP hair cells. Electrically tuned hair cells exhibited resonant frequencies from 50 to 375 Hz, which correlated well with hair cell position and the tonotopic organization of the papilla. Variations in the kinetics of the outward current contribute substantially to the determination of resonant frequency. ICa and IK(Ca) amplitudes increased with resonant frequency, reducing the membrane time constant with increasing resonant frequency. We conclude that a tonotopically organized hair cell substrate exists to support electrical tuning in the rostromedial region of the frog amphibian papilla and that the cellular mechanisms for frequency determination are very similar to those reported for another electrically tuned auditory organ, the turtle basilar papilla.

4-Aminopyridine↗

Evaluation of three gamma detectors for intraoperative detection of tumors using 111In-labeled radiopharmaceuticals.

UNLABELLED: Attempts to detect tumors with intraoperative scintillation using tumor-binding radiopharmaceuticals have intensified recently. In some cases previously unknown lesions were found, but in most cases no additional lesions were detected. In this study the physical characteristics of three detector systems and their ability to detect tumors through accumulation of an 111In-labeled radiopharmaceutical were investigated. The first was a sodium iodide (NaI[TI]) detector; the second, a cesium iodide (CsI[TI]) detector; and the third, a cadmium telluride (CdTe) detector. METHODS: A body phantom and tumor phantoms (diameter 5-20 mm) made of water, agarose gel or epoxy with a density and attenuation coefficient similar to those of soft tissue were used to simulate a clinical situation. The activity concentration in the body phantom was based on reported values of 111In-octreotide in normal tissue in humans. The 111In activity concentration in the tumor phantoms varied from 3 to 80 times the 111In activity concentration in the body phantom. Data were processed to determine tumor detection levels. RESULTS: The NaI(TI) detector showed the lowest values for full width at half maximum because this detector had the best collimation, leading to a high ratio between counts from tumor and counts from background, i.e., small tumors could be detected. Because of high efficiency, the CsI(TI) detector sometimes required a somewhat shorter acquisition time to produce a statistically significant difference between tumor phantom and background. For deep-lying tumors the NaI(TI) detector was superior, whereas the CdTe detector was best suited for superficial tumors with a high activity concentration in the underlying tissue. CONCLUSION: At a maximum acquisition time of 30 s, almost all superficial tumors with a diameter of 10 mm or larger were detected if the ratio between the 111In concentration in the tumor and the 111In concentration in the background exceeded 3. However, in clinical situations, biologic variations in the uptake of 111In-octreotide in tumors and in normal tissue makes difficult the determination of a distinct detection level. For such clinical conditions, the NaI(TI) detector is the best choice because it has good resolution despite a lower efficiency. Documentation of detector characteristics is important so that clinicians can make an adequate device in relation to tumor location and receptor expression.

Cadmium Compounds↗

[Feasibility study of CdTe Semiconductor detector for gamma camera--evaluation of planar images].

To evaluate the performance of a semiconductor detector for use in a gammacamera system, we assembled a detector with a small field of view--1 inch x 1 inch and 1 inch x 2 inch--made from CdTe (Cadmium telluride). We then compared the planar images and energy resolution of the resulting detectors against those of a conventional gammacamera. Pixel pitch of the detector was 1.6 mm x 1.6 mm, and was manufactured by Acrorad Corporation. Average FWHM of the energy spectrum for the semiconductor detector was 5.11% (SD: 0.80%, Best: 3.26%, Worst: 6.68%). The planar images obtained were of a letter phantom made from pieces of lead and of an IMP brain phantom. Since the field of view of the semiconductor detector was small, the image of the IMP brain phantom was acquired by moving the semiconductor over the collimated detector module until the area of the entire phantom was covered. The images from the semiconductor assembly were compared with those from a conventional gammacamera using the same conditions, and it was found that visual image quality was superior to those of the conventional camera system.

Brain↗

Burning mouth syndrome due to cadmium in a denture wearer.

We report the case of a female denture wearer who was referred to our service due to burning of the lips and tongue but with no visible oral lesions. Her biochemical data, complete blood cell count, sedimentation rate, thyroid and sex hormones were normal. Tongue culture was negative. Patch tests, performed with a panel of 20 potential denture allergens, gave positive results (+++) only to a 2% petrolatum cadmium sulfate, which was present in the denture. Removal of the denture led to the clearing up of oral symptoms in 3 days. In light of these findings, carrying out patch tests with the allergens related to denture materials should be considered in these cases.

Allergens↗

Influence of cadmium and zinc sulphates on the function of human T lymphocytes in vitro.

Substances present in our environment influence the whole organism, including the immune system. Metals are one of the principal parts of these substances. It is generally supposed that they may have stimulating effect on immunity system in low concentrations in comparison with high concentrations in which they are toxic, with variations of each metal. There are differences between for example cadmium and zinc, and cadmium is toxic in low concentrations either. The effect of cadmium on the immune system has not been studied so deeply as the influence of zinc. In our work, we are interested in the study of immunomodulation caused by cadmium in comparison with the influence of zinc. We tested the effect of cadmium and zinc sulphates on human T lymphocytes in vitro. Molar concentrations of salts used in our work were from 10(-2) M to 10(-10) M. The influence of metals on lymphocytes in cell culture was studied by the expression of surface antigen CD69, blast transformation and IL-2 and IL-4 intracellular production after 2, 24 and 72 h cultivation. Cells were analyzed by flow cytometry using monoclonal antibodies. The results show more expressive differences in blast transformation. There are stimulating effects of cadmium in concentrations 10(-3) M, 10(-4) M and 10(-8) M, and zinc 10(-3) M. The most suppressive effect is in concentrations 10(-10) M of cadmium and 10(-8) M of zinc. The highest CD69 expression is in concentrations 10(-4) M to 10(-6) M of cadmium, and 10(-3) M of zinc. There are minimal differences in intracellular cytokine production in CD4+ lymphocytes effected by various metal concentrations used and between cadmium and zinc salts after 2 hours cultivation. There is the elevation of cytokines negative cells after the cultivation lasting 24 hours. Our investigation of metals' influence by different methods shows possibilities for further research.

Adult↗

Subsite specificity of divalent metal ions to glucosyltransferase.

Glucosyltransferase from oral bacteria Streptococcus mutans is the most significant virulent factor in causing dental caries. The enzyme has two subsites. The binding specificity of divalent metal ions to glucosyl or fructosyl subsite was examined using multiple inhibition kinetics. The interaction factor "alpha" identifies whether the two subsites are exclusive or non-exclusive.

Binding Sites↗