Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “quantification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42Linked to original sources

Image analysis quantification of peptide-immunoreactive nerves in the skin of patients with Raynaud's phenomenon and systemic sclerosis.

Image analysis quantification was used to assess the results of immunocytochemistry for a neuronal marker and neuropeptides in digital skin biopsies from Raynaud's phenomenon (RP) and systemic sclerosis (SS) patients, to verify the possibility of a selective quantitative abnormality of immunoreactive nerves. The field area of specific immunostaining and nerve counts were evaluated on coded specimens, and the data compared by statistical analysis. Nerves immunoreactive for protein gene product 9.5 (PGP), a marker for neuronal elements, were decreased significantly in epidermal and subepidermal layers of digital skin in RP patients (P less than 0.0001). This change was paralleled by a decrease of calcitonin gene-related peptide (CGRP) immunoreactive nerves in the epidermis and around capillaries in the dermal papillae (P = 0.005). In the skin of RP patients, these changes were readily demonstrated by image analysis, although they were not always apparent on visual screening. In digital skin of SS patients, there was a generalized and very significant decrease of PGP, CGRP, and VIP immunoreactivities in all areas (P less than 0.0001). These results demonstrate that neuropeptide-containing nerves are involved in the digital pathology of RP and SS, and that image analysis quantification is an accurate and sensitive method for assessing morphological changes in pathological samples.

Adult↗

Quantification of the production of dihydrokaempferol by flavanone 3-hydroxytransferase using capillary electrophoresis.

A sensitive method using capillary electrophoresis for the separation, detection, and quantification of dihydrokaempferol (1) is reported. Well-resolved, sharp symmetrical peaks were obtained in grapefruit leaf extracts for 1, naringenin (2), and the internal standard, naringin (3). Long columns were required to resolve 1 from 2 in crude enzyme reactions and this resulted in run times of 60 min. The limit of detection for 1 was found to be 1.44 ng/microL (4.2 pg). The method showed excellent linearity and reproducibility. The method was used to determine the activity of flavanone 3-hydroxytransferase (F3H) in leaf tissue of grapefruit by quantification of the production of dihydrokaempferol in controlled time course reactions. The sensitivity of the method makes it adaptable to assaying F3H activity in individual young seedlings and/or in small tissue samples and requires only 100 mg of tissue.

Citrus↗

Direct quantification of fetal cells in maternal blood by real-time PCR.

BACKGROUND: Fetal cells in maternal blood still present an enticing alternative for the development of a safe and efficacious non-invasive method for prenatal diagnosis. However, most enrichment methods are very tedious and have failed to realise this long sought after goal. We developed a simple, robust TaqMan real-time PCR assay to directly quantify male fetal cells in maternal blood using the multi-copy DYS14, without the need for any additional enrichment procedure. METHODS: The sensitivity of the DYS14 assay was evaluated by using female genomic DNA spiked with male DNA or male cells. The specificity of the DYS14 assay was evaluated by examining 40 adult blood samples and 44 maternal blood samples from pregnant women with known fetal gender. Direct quantification of fetal cells in maternal blood was performed in 14 of the maternal blood samples by the DYS14 assay. The results were compared to those by SRY assay. RESULTS: The sensitivity of DYS14 PCR assay was found to be higher than that of SRY assay for the detection of fetal cells. The number of fetal cells in maternal blood did not exceed 2/mL blood. The presence of cell-free fetal DNA in maternal blood could lead to erroneous quantification of fetal cell DNA. The number of fetal cells detected in blood cell pellets, which had been unwashed to remove the cell-free fetal DNA, was indeed significantly higher than those in extensively washed samples. CONCLUSIONS: We quantified the fetal cells in maternal blood without fetal cell enrichment procedures by TaqMan real-time PCR for a multi-copy DYS14 locus. Our assay is sensitive and also suitable for automation, and may be a useful tool for the determination of fetal-maternal cell trafficking, such as microchimerism.

Chromosomes, Human, Y↗

Identification and relative quantification of membrane proteins by surface biotinylation and two-dimensional peptide mapping.

Membrane proteins play a central role in biological processes, but their separation and quantification using two-dimensional gel electrophoresis is often limited by their poor solubility and relatively low abundance. We now present a method for the simultaneous recovery, separation, identification, and relative quantification of membrane proteins, following their selective covalent modification with a cleavable biotin derivative. After cell lysis, biotinylated proteins are purified on streptavidin-coated resin and proteolytically digested. The resulting peptides are analyzed by high-pressure liquid chromatography and mass spectrometry, thus yielding a two-dimensional peptide map. Matrix assisted laser desorption/ionization-time of flight signal intensity of peptides, in the presence of internal standards, is used to quantify the relative abundance of membrane proteins from cells treated in different experimental conditions. As experimental examples, we present (i) an analysis of a BSA-spiked human embryonic kidney membrane protein extract, and (ii) an analysis of membrane proteins of human umbilical vein endothelial cells cultured in normoxic and hypoxic conditions. This last study allowed the recovery of the vascular endothelial-cadherin/actin/catenin complex, revealing an increased accumulation of beta-catenin at 2% O(2) concentration.

Biotinylation↗

Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform.

Mass spectrometry is being used to find disease-related patterns in mixtures of proteins derived from biological fluids. Questions have been raised about the reproducibility and reliability of peak quantifications using this technology. We collected nipple aspirate fluid from breast cancer patients and healthy women, pooled them into a quality control sample, and produced 24 replicate SELDI spectra. We developed a novel algorithm to process the spectra, denoising with the undecimated discrete wavelet transform (UDWT), and evaluated it for consistency and reproducibility. UDWT efficiently decomposes spectra into noise and signal. The noise is consistent and uncorrelated. Baseline correction produces isolated peak clusters separated by flat regions. Our method reproducibly detects more peaks than the method implemented in Ciphergen software. After normalization and log transformation, the mean coefficient of variation of peak heights is 10.6%. Our method to process spectra provides improvements over existing methods. Denoising using the UDWT appears to be an important step toward obtaining results that are more accurate. It improves the reproducibility of quantifications and supplies tools for investigation of the variations in the technology more carefully. Further study will be required, because we do not have a gold standard providing an objective assessment of which peaks are present in the samples.

Algorithms↗

Targeted proteomics in biomarker validation: detection and quantification of proteins using a multi-dimensional peptide separation strategy.

Authentic biomarkers, distilling the essence of a complex, functionally significant process in a mammalian system into a precise, physicochemical measurement have been implicated as a tool of increasing importance for drug discovery and development. However, even in spite of recent technological advances, validating a new biomarker candidate, where generation of suitable antibodies is required, is still a long-lasting task. Methods to accelerate initial validation by MS approaches have been suggested, but all methods described so far are associated with serious drawbacks, finally leading to non-generic methods of detection and quantification. Moreover, when complex body fluids are used as samples, efficient debulking strategies are crucial to open a window of analytical sensitivity in the ng/mL range, where many diagnostically relevant analytes are present. Here we report the proof-of-principle of a multi-dimensional strategy for accelerated initial validation of biomarker candidates by MS, which promises to be generally applicable, sensitive and quantitative. The method presented employs a combination of electrophoretic and chromatographic steps on the peptide level, followed by MS quantification using isotopically labeled synthetic peptides as internal standards. Our proposed workflow includes up to four dimensions, finally resulting in a desired LOD sufficient to detect and quantify diagnostically relevant analytes from complex samples. Although the current state of the method only represents a starting point for further validation and development, it reveals great potential in biomarker validation.

Animals↗

Protein abundance quantification in embryonic stem cells using incomplete metabolic labelling with 15N amino acids, matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry, and analysis of relative isotopologue abundances of peptides.

An isotope dilution method for protein quantification is presented in the context of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) and mass fingerprinting experiments, revealing an unappreciated high reproducibility and accuracy of relative peak intensity measurements. Labelled proteins were generated by growing cells in a medium containing (15)N-enriched amino acids, and were mixed with proteins of natural isotopic composition from control cells in ratios of approximately 0:1, 1:7, 1:2, 2:1, 7:1, and 1:0 (labelled/unlabelled). Mixtures were separated by two-dimensional gel electrophoresis and analysed by MALDI-TOFMS using typical experimental conditions. A linear relationship is demonstrated between the relative isotopologue abundances (RIA values) for particular peaks in the isotopic distribution of tryptic peptide fragments of the proteins, and the mole fractions of labelled proteins in the mixture. Analysis of RIA values (ARIA quantification) for peptides of six typical silver-stained protein spots for the various mixtures could reproduce the experimentally contrived ratios with approximate errors between 4% (2:1 mixture) and about 18% (1:7 mixture). A consideration of error and its propagation is discussed. ARIA does not require complete separation of the isotope patterns of labelled and unlabelled peptides, and is therefore advantageous in combination with all kinds of labelling experiments in biological systems, because it is compatible with minimal metabolic incorporation of labelling reagent. Simulations indicate that the minimum required (15)N enrichment of the total amino acid pool sufficient for ARIA is less than 4%. In an accompanying paper in this issue, we apply ARIA to proteins differentially labelled with isotope-coded alkylation reagents.

Amino Acids↗

Application of the fast-evaporation sample preparation method for improving quantification of angiotensin II by matrix-assisted laser desorption/ionization.

The fast-evaporation method of sample preparation has been applied for quantitative analysis using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. An instrumental protocol focusing on improvement of shot-to-shot repeatability and compensation for signal degradation has been developed for quantification of angiotensin II using the fast-evaporation technique and an internal standard. The fast-evaporation method was compared to the standard method of sample preparation (using a multicomponent matrix) in the quantitative analysis of angiotensin II, and found to be superior in several respects. Improvement in sample homogeneity using the fast-evaporation method enhanced both point-to-point repeatibility and sample-to-sample reproducibility. The relative standard deviations of the analyte/internal standard ratios (point RSD) were decreased by a factor of three compared to those obtained using the multicomponent matrix method. The average point RSD was found to be ca. 5% for the fast-evaporation technique. Two internal standards were evaluated for quantification of angiotensin II. The better one, 1-SAR-8-Ile angiotensin II, yielded a relative standard deviation of the standard curve slope of ca. 2.2% over two orders of magnitude of concentration (45 nM to 3000 nM), an improvement by a factor of two over the standard preparation method. Renal microdialysate samples, spiked with angiotensin II and the internal standard 1-SAR-8-Ile angiotensin II, were also analyzed using the fast-evaporation technique. The detection limit was calculated to be in the high attomole range (675 amol). Furthermore, the accuracy for a single determination of angiotensin II concentration in these samples was found to be 13.9% with a relative error of 8.19%.

1-Sarcosine-8-Isoleucine Angiotensin II↗

Quantification of cyclophosphamide and its metabolites in urine using liquid chromatography/tandem mass spectrometry.

A reliable and easy to use liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous quantification of urinary concentrations of cyclophosphamide (CP) and its main metabolites excreted in urine, i.e. N-dechloroethylcyclophosphamide (DCL-CP), 4-ketocyclophosphamide (4KetoCP), and carboxyphosphamide (CarboxyCP). Sample preparation consisted of dilution of urine with an aqueous solution of the internal standard D(4)-CP and methanol, and centrifugation. LC/MS/MS detection was performed using a triple-quadrupole mass spectrometer working in selected reaction monitoring mode. All analytes were quantified in a single run within 11.5 min. The limits of detection were 5 ng/mL for CP and 4KetoCP, 1 ng/mL for DCL-CP, and 30 ng/mL for CarboxyCP. Quantification ranges were adjusted to the expected concentrations in 24-h urine collections of patients treated with a polychemotherapy regimen (3-175 microg/mL for CP, 0.5-27 microg/mL for 4KetoCP and 0.17-9 microg/mL for CarboxyCP and DCL-CP, respectively). The method was validated according to international guidelines of the ICH and the FDA.

Calibration↗

Trace level quantification of deuterated 17beta-estradiol and estrone in ovariectomized mouse plasma and brain using liquid chromatography/tandem mass spectrometry following dansylation reaction.

A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with dansylation was developed for the simultaneous quantification of exogenously administered deuterated 17beta-estradiol-d4 (E2-d4) and its metabolite, estrone-d4 (E1-d4), in mouse plasma and brain homogenates. The dansylation reaction was simple, fast, and sensitive, and a lower limit of quantification of 50 pg/mL was achieved by using 50 microL of mouse plasma. Interference from endogenous 17beta-estradiol and estrone in plasma and brain samples was minimized by the use of deuterated-E2 as well by utilizing ovariectomized (OVX) mice. The recovery of dansylated derivative exceeded 83% and the reaction was completed within approximately 3 min. The intra- and inter-day assay precision were better than 12.9% and assay accuracy ranged between 92-104% for E1-d4 and E2-d4 in plasma, respectively. The absorption of E2-d4 at both 1 and 3 mg/kg P.O. was rapid, reaching peak plasma concentrations (Cmax) at 5 min post-dose that was the earliest time point obtained, and were 1.1 and 13.8 ng/mL, respectively; the Cmax values for the estrone metabolite, E1-d4, were 1.1 and 43.2 ng/mL, respectively. The area-under-the-plasma-time curve (AUC(0-2 h)) values were determined to be 0.65 and 2.90 ng. h/mL for E2-d4 and 0.77 and 6.74 ng. h/mL for E1-d4, respectively, at 1 and 3 mg/kg. The mean brain-to-plasma ratio for E1-d4 and E2-d4 after P.O. administration of E2-d4 to the OVX mice at 1 and 3 mg/kg indicated that both E1-d4 and E2-d4 were present in the brain as well as in the circulation.

Animals↗

A simple method for the characterization and quantification of soy isoflavone metabolites in the serum of MMTV-Neu mice using high-performance liquid chromatography/electrospray ionization mass spectrometry with multiple reaction monitoring.

In a study aimed at elucidation of the possible role of dietary phytoestrogens in the growth of breast cancer, it was necessary to develop a convenient, accurate, and reproducible method for the characterization and quantification of isoflavone metabolites in the serum of MMTV mice that were fed diets containing different amounts of these polyphenols. The analytical method is based on liquid chromatography with mass spectrometry in multiple reaction monitoring mode, using deuterated genistein as internal standard. The identified metabolites were genistein and dihydrodaidzein (DHD); their average concentrations in serum were 0.71 and 0.21 microM, respectively, for animals fed 1.5 mg/day of genistein and 0.7 mg/day of daidzein. This method assured a limit of quantification of 0.04 microM for genistein and 0.08 microM for DHD, and a limit of detection of 0.018 microM for genistein and 0.035 microM for DHD. The coefficient of variation was 8.9% for genistein and lower than 15% for DHD. This study provides the first data indicating the presence of dihydrodaidzein in serum of mice fed diets containing soy proteins.

Administration, Oral↗

Development of a liquid chromatography/electrospray tandem mass spectrometry assay for the quantification of apicidin, a novel histone deacetylase inhibitor, in rat serum: application to a pharmacokinetic study.

Apicidin, a fungal metabolite isolated from Fusarium pallidoroseum, is a cyclic tetrapeptide that exhibits potent anti-protozoal and anti-angiogenic activities. Although extensive studies have been recently conducted to examine the biological and pharmacological action, no information is available on the quantitative analysis of apicidin. To our knowledge, this study is the first to describe a rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay method for the quantification of apicidin in rat serum. The method was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), accuracy, and precision. The multiple reaction monitoring was based on the transitions m/z 624.7 --> 84.3 and 372.1 --> 176.1 for apicidin and trazodone, respectively. The assay utilized a single liquid-liquid extraction and isocratic elution, and the LLOQ was 0.5 ng/mL using 0.1 mL of rat serum. The assay was linear over a range from 0.5-1000 ng/mL, with correlation coefficients >0.9994. The mean intra- and inter-day assay accuracy ranged from 99.9-101.5% and 94.8-102.1%, respectively, and the mean intra- and inter-day precision was between 2.7-5.9% and 1.6-11.5%, respectively. The developed assay method was applied to a pharmacokinetic study after intravenous injection of apicidin in rats at a dose of 1 mg/kg.

Animals↗

Liquid chromatography/electrospray ionization mass spectrometry method for the quantification of valproic acid in human plasma.

A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.

Anticonvulsants↗

Simultaneous quantification of fludarabine and cyclophosphamide in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

Fludarabine and cyclophosphamide are anticancer agents mainly used in the treatment of hematologic malignancies. We have developed and validated an assay using high-performance liquid chromatography (HPLC) coupled with electrospray ionization tandem mass spectrometry for the quantification of fludarabine in combination with cyclophosphamide in human heparin and human EDTA plasma. Sample pre-treatment consisted of a protein precipitation with cold acetonitrile (-20 degrees C) using 250 microL of plasma. Separation was performed on an Extend C18 column (150 x 2.1 mm i.d.; 5 microm) with a stepwise gradient using 1 mM ammonia solution and acetonitrile at a flow rate of 400 microL/min. The analytical run time was 12 min. The triple quadrupole mass spectrometer was operated in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over a concentration range of 1 to 100 ng/mL for fludarabine and cyclophosphamide in human heparin and human EDTA plasma. The coefficients of variation were <13.9% for inter- and intra-day precisions. Mean accuracies were also within the designated limits (+/-15%). The analytes were stable in plasma, processed extracts and in stock solution under all relevant conditions.

Antineoplastic Agents↗

High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry.

A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.

Animals↗

Combined use of gas chromatography and selected ion flow tube mass spectrometry for absolute trace gas quantification.

The value of the gas chromatography (GC) and selected ion flow tube mass spectrometry (SIFT-MS) combination for the analysis of trace gases is demonstrated by the quantification of acetone in air samples using the three precursor ions available to SIFT-MS, viz. H3O+, NO+ and O2+, and by the separation of the isomers 1-propanol and 2-propanol, and their analysis using H3O+ precursor ions. It is shown that the GC/SIFT-MS combination allows for accurate trace gas quantification obviating the regular, time-consuming calibrations that are usually required for the more commonly used detectors of GC systems, and the positive identification of isomers in mixtures that is often challenging using SIFT-MS alone. Thus, the GC/SIFT-MS combination paves the way to more confident analyses of complex mixtures such as exhaled breath.

Journal Article↗

High-throughput quantification of perindopril in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study.

A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of perindopril in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 369/172 for perindopril and m/z 417/234 for the internal standard. The method exhibited a linear dynamic range of 0.1-100 ng/mL for perindopril in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 6.1%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 450 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.

Angiotensin-Converting Enzyme Inhibitors↗

An extensive study on isosorbide-5-mononitrate acid adducts for quantification in human plasma using liquid chromatography/electrospray ionization tandem mass spectrometry and its application to bioequivalence sample analysis.

A rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the determination of isosorbide-5-mononitrate (5-ISMN), used in the treatment of angina pectoris, in human plasma is described. The quantification of 5-ISMN was performed via stable acetate adduct formation with a high relative abundance. The plasma filtrate obtained after solid-phase extraction (SPE), using a polymer based, hydrophilic-lipophilic balanced (HLB) cartridge, was submitted directly to reversed-phase high-performance liquid chromatography separation followed by ESI and detection of the resulting ions using triple-quadrupole mass spectrometry in selected reaction monitoring (SRM) mode. There was no significant matrix effect on the analysis. For validation of the method, the recovery of the free analyte response was compared to that obtained from an optimized extraction method. The analyte stability was examined under conditions mimicking the sample storage, handling, and analytical procedures. The extraction procedure yielded extremely clean extracts with a recovery of 95.51% and 93.98% for iossorbide-5-mononitrate and topiramate (internal standard (IS)), respectively. The calibration curves were linear for the dynamic range of 10.0 to 1000.0 ng/mL with a correlation coefficient r > or = 0.9985. The intra-assay and inter-assay precision for the samples at the lower limit of quantification (LLOQ) were 9.02 and 13.30%, respectively. The intra-assay accuracies at LLOQ, LQC, MQC and HQC levels varied from 98.13 to 118.15, 102.34 to 105.21, 100.69 to 109.68, and 95.76 to 102.92%, respectively, while the inter-assay accuracies ranged from 93.10 to 118.15, 93.03 to 107.04, 86.97 to 109.68 and 86.18 to 105.85%, respectively, at these levels. The method is rugged and fast with a total run time of 2 min. The method was successfully applied for a bioequivalence study in 24 human subject samples after oral administration of 60 mg extended release (ER) formulations.

Acetylation↗