Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Protective Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42Linked to original sources

[Radiation protection measures for diagnostic x-ray equipment].

The operation of x-ray equipment requires protective devices, organisational measures and observation of rules. First of all, the paper deals with typical dose values of scattered radiation and the consequences for the absorbed dose. Classification into areas subject to routine supervision and to close control, and into protected areas, is explained. The major part of the paper deals with the radiation protection measures of typical diagnostic x-ray equipment.

Radiation Protection↗

The treatment of carotid artery bifurcation stenoses with systematic stenting: experience of first 100 consecutive cardiological procedures.

Carotid endarterectomy still represents the gold standard treatment of carotid artery bifurcation stenosis but percutaneous angioplasty with stenting is rapidly growing as a non-invasive alternative. In this paper we report the results of systematic application of carotid stenting performed in a cardiological setting, particularly as regards clinical management of patients and technical approach. One-hundred (100) procedures of carotid artery stenting (CAS) on 94 consecutive patients, both symptomatic and asymptomatic, with a carotid stenosis > 70%, were performed over a period of 30 months. The technical approach was directly derived from coronary angioplasty with use of large lumen guiding catheters, 0.014 in. intravascular guidewires and distal protection devices usually employed in coronary interventions. In 3 cases, a post-carotid endarterectomy restenosis and in 97 cases, a de-novo lesion, were treated respectively; in 71 cases, the degree of stenosis was 71-89% and in 29 cases, 90-99%. Cerebral protection was obtained with a distal to the lesion endovascular filter in 63 cases. Immediate technical success, i.e. residual stenosis of the treated vessel < 30% and no significant pathologic acceleration of blood flow (< 1.5 m/sec) at the Doppler ultrasound evaluation, was achieved in all procedures (100%). Ninety-six (96) procedures were totally uncomplicated; in-hospital cerebral complications were 1 TIA, 2 minor and 1 major strokes; at 30-day follow-up one additional major stroke occurred. Despite a particularly high incidence of comorbidities, neither unfavorable cardiological complications nor neurologic deaths were reported. Systematic CAS is a feasible treatment of the carotid artery bifurcation stenosis with high procedural success and low perioperative and short term complications. Its performance in a cardiological setting can combine satisfying procedural results and potentially successful handling of cardiovascular complications.

Aged↗

Extraction of large intracoronary thrombus in acute myocardial infarction by percutaneous Fogarty maneuver: intentional abuse of a novel interventional device.

Intracoronary thrombus in the infarct-related artery remains a challenge for interventional catheter-based techniques in acute myocardial infarction and may result in severe complications due to distal embolization. We describe a patient with acute myocardial infarction in whom a large intracoronary thrombus of the left anterior descending coronary artery was successfully removed by percutaneous Fogarty maneuver using an expanded filter protection device.

Adult↗

Pharmacological rescue of noise induced hearing loss using N-acetylcysteine and acetyl-L-carnitine.

Despite the use of hearing protection devices (HPDs) and engineering changes designed to improve workspaces, noise-induced hearing loss continues to be one of the most common and expensive disabilities in the US military. Many service members suffer acoustic trauma due to improper use of HPDs, sound levels exceeding the protective capacity of the HPDs, or by unexpected, injurious exposures. In these cases, there is no definitive treatment for the hearing loss. This study investigated the use of the pharmacological agents N-acetylcysteine and acetyl-L-carnitine after acoustic trauma to treat cochlear injury. N-Acetylcysteine is an antioxidant and acetyl-L-carnitine a compound that maintains mitochondrial bio-energy and integrity. N-Acetylcysteine and acetyl-L-carnitine, respectively, significantly reduced permanent threshold shifts and hair cell loss compared to saline-treated animals when given 1 and 4 h post-noise exposure. It may be possible to obtain a greater therapeutic effect using these agents in combination or at higher doses or for a longer period of time to address the secondary oxidative events occurring 7-10 days after acute noise exposure.

Acetylcarnitine↗

Multicenter evaluation of carotid artery stenting with a filter protection system.

OBJECTIVES: The aim of this study was to evaluate the feasibility and safety of carotid artery stenting (CAS) with a filter protection system. BACKGROUND: Neurologic events linked to the embolization of particulate matter to the cerebral circulation may complicate CAS. Strategies designed to capture embolic particles during carotid intervention are being evaluated for their efficacy in reducing the risk of these events. METHODS: Between September 1999 and July 2001, a total of 162 patients (164 hemispheres) underwent CAS with filter protection (NeuroShield, MedNova Ltd., Galway, Ireland) according to prospective protocols evaluating the filter system at three institutions. RESULTS: Angiographic success was achieved in 162 of the procedures (99%) and filter placement was successful in 154 (94%) procedures. Carotid access was unsuccessful in two cases (1%) and filter placement in eight cases (5%). Of the latter, five procedures were completed with no protection and three were completed using alternative protection devices. On an intention-to-treat basis, the overall combined 30-day rate of all-stroke and death was 2% (four events: two minor strokes and two deaths). This includes one minor stroke in a patient with failed filter placement and CAS completed without protection. There was one cardiac arrhythmic death and one death from hyperperfusion-related intracerebral hemorrhage. There were no major embolic strokes. CONCLUSIONS: Carotid artery stenting with filter protection is technically feasible and safe. Early clinical outcomes appear to be favorable and need to be confirmed in a larger comparative study.

Aged↗

Effect of percutaneous coronary interventions for in-stent restenosis in degenerated saphenous vein grafts without distal embolic protection.

OBJECTIVES: This study was designed to investigate the impact of percutaneous coronary interventions (PCIs) in degenerated saphenous vein grafts (SVGs) without distal embolic protection. BACKGROUND: Distal embolic protection devices have been shown to reduce the incidence of no reflow/slow flow during PCI of de novo lesions in degenerated SVGs. It is unclear whether PCI of in-stent restenosis (ISR) lesions in degenerated SVGs is associated with no reflow/slow flow and whether distal embolic protection is beneficial in these cases as well. METHODS: We studied 54 consecutive patients with treated ISR lesions in degenerated SVGs who underwent PCI without distal embolic protection in a single center. Procedural and in-hospital outcomes were examined. The average age was 71 +/- 8 years; 32% of the patients had diabetes. The mean lesion length was 13 +/- 6 mm and the procedural success rate was 98% (53/54). Cutting balloon angioplasty was used in 46% (25/54) of cases, and a new stent was inserted in 46% (25/54) of patients. Gamma brachytherapy was performed in 19% (10/54) of patients. During the procedure there were no episodes of no reflow/slow flow, and there were no patients with in-hospital Q-wave or non-Q-wave myocardial infarction. There was one in-hospital noncardiac death. CONCLUSIONS: In this consecutive series of patients with ISR of degenerated SVGs undergoing PCI without distal protection, there were no episodes of slow flow/no reflow and no procedure-related myocardial infarctions. It appears that distal embolic protection may not be necessary during PCI of ISR lesions in degenerated SVGs.

Aged↗

[Device for analyzing roentgen images].

Analyzer of X-ray images includes a photodetector array with online memory, a single-purpose computer and an imager for the memory contents. The photodetector array incorporates 2 X (64 X 128) bistable photocells, their action potentials are adjusted for brightness. The analyzer is the most useful in verifying parallelism of absorbing plates in X-ray grids, in checking protective devices, and in processing mammograms.

Computers↗

[Hygienic and physiological aspects of evaluation of new types of protective clothing for railroad workers].

In the Soviet rail-road transport system, timely provision of individual protective devices was authorized by a special instruction of the Rail-Roads Transport Ministry. New materials and overalls are being introduced to adapt the individual safety measures to new labour conditions and the new chemical substances used in the rail-road transport system. Hygienic, physiological and laboratory techniques are widely used to assess the properties of new devices. The evaluating techniques and approaches used and improved in the transport industry can be applied to in other branches.

Humans↗

Sharps injuries: defining prevention priorities.

OBJECTIVE: An institutional review of sharps injuries was conducted to assist in establishing priorities for resource allocation in a sharps prevention program. DESIGN: A retrospective review of 221 sharps injuries occurring during a 1-year period was conducted by a 4-member multidisciplinary team. Each injury was categorized as either moderate/high, low, or unknown risk for acquisition of bloodborne diseases by using modified provincial definitions of occupational risk for exposure to bloodborne pathogens. RESULTS: A total of 119 injuries were considered to be moderate/high risk, and 93 were at low risk for acquisition of bloodborne disease. Nine injuries could not be categorized. In 59% of high-risk injuries, education or changes in technique were identified as the primary preventive intervention. Passive devices such as needleless intravenous administration sets could theoretically address prevention of the majority of low-risk injuries. Known available safety devices could have prevented 33 (28%) high-risk injuries. CONCLUSION: Disposition of resources must take into consideration the risk of bloodborne disease acquisition and the efficiency and expense of the preventable methods employed. Institutional review of injuries combined with a cost analysis revealed that resources were best allocated to protective devices at source (eg, safety syringes) and on a comprehensive, multidisciplinary, and sustained educational program. Needleless intravenous infusion sets would mainly prevent low-risk injuries at significant cost.

British Columbia↗

[Evaluation of the X-ray exposure dosage during coronary cineangiography].

PURPOSE: To study the radiation doses during cardiac catheterization. PATIENTS AND METHODS: Thermoluminescents dosimeters were placed over a phantom's cardiac area, measuring both entrance and exit of the X-ray beam to check the absorbed dose. We could measure the doses in the examiner with dosimeters in frontal and hand's back regions. RESULTS: The average rate of exposure in the cinefilmstep increases in the 5.2 times the average rate measured in the fluoroscopy mode. The dose absorbed by the patient was of 114 mGy during a total of 20 min X-ray exposure time (e.g. 15 min of fluoroscopy and 1 min of film). Compared to the results obtained with the phantom's dose we have found a relative error of 20. Under the same exposure time we wave found a 0.68 mSv dose in the examiner's hands and a 0.40 mSv dose in his eyes. CONCLUSION: In this kind of procedure the examiner should have special concern as to observe the appropriate technical conditions besides having to make use of individual protection devices to minimize the radiation doses on his own behalf and behalf of his patient.

Adult↗

Side impact crashes--factors affecting incidence and severity: review of the literature.

Many traffic crashes are side impact collisions resulting in significant death and injury. A review was conducted of the evidence of driver, road, and vehicle characteristics affecting either the risk of occurrence or the severity of injury in such crashes for papers published from 1996 to early 2003. For drivers, evidence was found of increased crash risk or injury severity only for age and age-related medical conditions (e.g., dementia). Traffic roundabouts and other traffic control devices--stop signs, traffic lights, and so on--had mixed results; traffic controls were better than no controls, but their effectiveness varied with circumstance. Most vehicle characteristics have had little or no effect on crash occurrence. Antilock braking systems (ABS) in the striking vehicle had been anticipated to reduce the risk of crashes, but so far have demonstrated little effect. The primary emphasis in vehicle design has been on protective devices to reduce the severity of injury. Disparity in the size of the two vehicles, especially when the struck vehicle is smaller and lighter, is almost a consistent risk factor for occupant injury. The occupants of light trucks, however, when struck by passengers cars on the opposite side, were at higher risk of injury. Wearing seat belts had a consistently protective effect; airbags did not, but there were few studies, and no field studies, of lateral airbags found. Of all the characteristics examined, vehicle design, including occupant restraints, is the most easily modified in the short term, although road design, traffic control, and the monitoring of older drivers may also prove effective in reducing side impact crashes in the longer term.

Accident Prevention↗

[Optimizing staff radiation protection in radiology by minimizing the effective dose].

PURPOSE: In the present study the optimization of radiation protection devices is achieved by minimizing the effective dose of the staff members since the stochastic radiation effects correlate to the effective dose. MATERIALS AND METHODS: Radiation exposure dosimetry was performed with TLD measurements using one Alderson Phantom in the patient position and a second phantom in the typical position of the personnel. Various types of protective clothing as well as fixed shields were considered in the calculations. RESULTS: It was shown that the doses of the unshielded organs (thyroid, parts of the active bone marrow) contribute significantly to the effective dose of the staff. Therefore, there is no linear relationship between the shielding factors for protective garments and the effective dose. An additional thyroid protection collar reduces the effective dose by a factor of 1.7 - 3.0. X-ray protective clothing with a 0.35 mm lead equivalent and an additional thyroid protection collar provides better protection against radiation than an apron with a 0.5 mm lead equivalent but no collar. CONCLUSION: The use of thyroid protection collars is an effective preventive measure against exceeding occupational organ dose limits, and a thyroid shield also considerably reduces the effective dose. Therefore, thyroid protection collars should be a required component of anti-X protection.

Health Personnel↗

Embolic protection: limitations of current technology and novel concepts.

Distal embolic event is one of the major limitations of coronary and non-coronary vascular interventions. Balloon and filter-based Embolic Protection Devices (EPDs) are a new class of interventional devices, used to prevent consequential morbidity and mortality of the distal embolic events. Data from first generation EPD supply proof of concept and show approximately 40% reduction in mortality and morbidity, when EPDs are used during saphenous vein grafts (SVGs) interventions. Current limitations of all first generation EPD technology taper their penetration. With breakthroughs in embolic protection technology, it is estimated that, in the near future, EPDs will be used with stenting in all high-risk lesions (SVGs, carotid arteries and acute coronary syndromes), become the standard of care and even be used in low risk cases.

Embolism↗

Acute health problems among subjects involved in the cleanup operation following the Prestige oil spill in Asturias and Cantabria (Spain).

The purpose of this study was to evaluate exposure conditions and acute health effects in subjects participating in the Prestige oil spill cleanup activities and the association between these and the nature of the work and use of protection devices in the regions of Asturias and Cantabria (Spain). The sample comprised 400 subjects in each region, selected from a random sampling of all persons involved in cleanup activities, stratified by type of worker and number of working days. Data were obtained via a structured questionnaire and included information on specific tasks, number of working days, use of protective materials, and acute health effects. These effects were classified into two broad groups: injuries and toxic effects. Data analysis was performed using complex survey methods. Significant differences between groups were evaluated using Pearson's chi(2) test. Unconditional logistic regression was used to compute odds ratios and 95% confidence intervals. Bird cleaners accounted for the highest prevalence of injuries (19% presented with lesions). Working more than 20 days in highly polluted areas was associated with increased risk of injury in all workers. Occurrence of toxic effects was higher among seamen, possibly due to higher exposure to fuel oil and its components. Toxic effects were more frequent among those working longer than 20 days in highly polluted areas, performing three or more different cleaning activities, having skin contact with fuel oil on head/neck or upper limbs, and eating while in contact with fuel or perceiving disturbing odors. No severe disorders were identified among individuals who performed these tasks. However, potential health impact should be considered when organizing cleanup activities in similar environmental disasters.

Accidents↗

Impact of diabetes on five-year outcomes after vein graft interventions performed prior to the drug-eluting stent era.

OBJECTIVE: The aim of this study was to evaluate the differences in 5-year outcomes among diabetic and nondiabetic patients undergoing saphenous vein graft (SVG) percutaneous coronary intervention (PCI) prior to the era of distal protection and drug-eluting stents. BACKGROUND: PCI of native coronary arteries is known to be associated with higher rates of adverse outcomes in diabetic patients compared to nondiabetic patients. However, the impact of diabetes on long-term outcomes after SVG interventions is not as well established. We conducted an evaluation of 5-year outcomes after SVG PCI in the two decades prior to the availability of distal protection devices and drug-eluting stents. METHODS: Data on 2,556 subjects (1,780 nondiabetic and 776 diabetic) undergoing SVG PCI at Emory Hospital from 1981 to 2001 were collected and entered into a computerized database and analyzed for adverse cardiovascular outcomes. RESULTS: Compared to the nondiabetic group, the diabetic group had worse 1-year (87.7% vs. 94.9%; p < 0.0001) and 5-year survival rates (62.9% vs. 78.5%; p < 0.0001). In the subset of patients receiving stents, 5-year survival remained significantly worse in the diabetic group (78.2% vs. 87.1%; p = 0.009). After multivariate analysis, diabetes was an independent predictor of 5-year mortality (hazard ratio = 1.8; 95% CI = 1.5-2.5; p < 0.0001). CONCLUSION: Diabetic patients undergoing vein graft PCI prior to the distal protection and drug-eluting stent era had significantly worse long-term outcomes compared to nondiabetic patients. The effect on long-term outcomes using these newer devices in diabetic subjects undergoing SVG PCI must be established for a true assessment of their impact.

Angioplasty, Balloon, Coronary↗

In vitro evaluation of the effectiveness of distal protection in the prevention of cerebral thromboembolism during carotid stent placement.

RATIONALE AND OBJECTIVES: The purpose of this in vitro study was to evaluate and quantify the benefit of the balloon protection device, to identify the most effective sequence of irrigation or flushing, and to determine the most effective catheter position to remove the maximum number of emboli or debris beneath the flow-arrest balloon. MATERIALS AND METHODS: Silicone models of the neurovasculature were attached to a systodiastolic pump. Stents were placed in carotid stenoses by using the distal flow protection technique. Embolic material was released within the stent. The effectiveness of different irrigation techniques was evaluated. RESULTS: Aspiration under the balloon through the guiding catheter with a 60-mL syringe followed by one power injection at 40 mL injected at 2 mL/sec will result in removal of about 98% of potential emboli from the internal carotid artery [corrected]. CONCLUSION: In vitro evaluation of the distal flow protection technique indicates that it should reduce stroke risk during carotid stent placement.

Carotid Stenosis↗

Carotid artery stenting with cerebral protection in 100 consecutive patients: immediate and two-year follow-up results.

BACKGROUND: Carotid artery stenting is emerging as an alternative to surgical endarterectomy for the treatment of extracranial carotid artery disease. However, few data are available on the long-term clinical efficacy of carotid artery stenting and on the incidence of restenosis. METHODS: Stent implantation with the routine use of cerebral protection devices was attempted in a single center experience including 100 consecutive patients (104 lesions) with significant stenosis of the internal carotid artery (mean stenosis 82.8 +/- 9%). The mean age of the patients was 70.8 +/- 14 years, 27 lesions were symptomatic (26.0%) with a lesion related to a previous stroke or transient ischemic attack. RESULTS: Procedural success was achieved in 103 lesions (99%) and the cerebral protection was successfully applied in 102 procedures (98%). The 30-day incidence of stroke and death was 4% (4 patients). Complications consisted of one major stroke (1%) with persistent ipsilateral amaurosis, two minor strokes (2%), and one (1%) fatal myocardial infarction occurring 4 days after the stent procedure. During follow-up (minimum 24 months; mean 31 +/- 6 months) no further neurological events occurred, 6 patients died of non-neurological causes (6%) and 2 (2%) presented with a non-fatal myocardial infarction. Echo color Doppler scan control (minimum 24 months) was carried out in all surviving patients showing a restenosis classified as moderate (50-69%) in 2 cases and as critical (> or = 70%) in another 2 cases (1.8%). Both critical restenotic lesions were successfully treated by repeating balloon angioplasty. CONCLUSIONS: The present study demonstrates that carotid artery stenting with routine cerebral protection can be performed with an acceptable procedural complication rate. At the 2-year follow-up carotid artery stenting appeared effective in stroke prevention and durable with a low incidence of restenosis.

Aged↗

A suggested approach to the selection of chemical and biological protective clothing--meeting industry and emergency response needs for protection against a variety of hazards.

The paper describes the development of a comprehensive decision logic for selection and use of biological and chemical protective clothing (BCPC). The decision logic recognizes the separate areas of BCPC use among emergency, biological, and chemical hazards. The proposed decision logic provides a system for type classifying BCPC in terms of its compliance with existing standards (for emergency applications), the overall clothing integrity, and the material barrier performance. Type classification is offered for garments, gloves, footwear, and eye/face protection devices. On the basis of multiple, but simply designed flowcharts, the type of BCPC appropriate for specific biological and chemical hazards can be selected. The decision logic also provides supplemental considerations for choosing appropriate BCPC features.

Decision Support Techniques↗