Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Hydroxyapatites”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42Linked to original sources

Abscessed hydroxyapatite orbital implants. A report of two cases.

PURPOSE: The authors describe the rare condition of an abscess within a hydroxyapatite orbital implant in two patients who had undergone seemingly uncomplicated enucleation and orbital implant surgery. METHODS: In the first patient, 14 weeks postoperatively, a chronic discharge developed and the socket became uncomfortable. A pyogenic granuloma was present, occurring over an area of dehiscence. The hydroxyapatite orbital implant was removed 10 months postoperatively. In the second patient, moderate orbital discomfort was noted during the first week postoperatively along with a temporal shift of the implant. The discomfort persisted, and 1 week later a discharge began. The implant was removed 9 weeks after implantation. At the time of surgery, an unsuspected pyogenic granuloma was found in the medial conjunctival formix overlying a small area of implant dehiscence. RESULTS: Conjunctival and implant cultures grew Staphylococcus aureus in our first patient, whereas coagulase-negative staphylococci were cultured from the conjunctiva and implant in our second patient. Results of histopathologic examination of both implants disclosed an abscess cavity containing clusters of gram-positive cocci. CONCLUSION: Persistent orbital discomfort, discharge, and the development of a pyogenic granuloma after hydroxyapatite implant should warn the ophthalmic surgeon of potential implant infection.

Abscess↗

Complications of hydroxyapatite orbital implants. A review of 100 consecutive cases and a comparison of Dexon mesh (polyglycolic acid) with scleral wrapping.

PURPOSE: The authors analyzed all the complications associates with the first 100 hydroxyapatite orbital implants performed by one surgeon, and compare scleral wrapping versus Dexon mesh (polyglycolic acid, Davis & Geck, Manati, Puerto Rico) wrapping in light of these complications. BACKGROUND: Prior studies have not included the full range of complications that can occur with hydroxyapatite orbital implants. Dexon mesh implant wrapping is a promising substitute for sclera and avoids the risks involved in using donor tissue. METHODS: A retrospective analysis of 100 consecutive cases was performed. RESULTS: Many minor complications occurred, but the rate of exposure was low (3%) and no implant was lost. Dexon mesh wrapping was similar to scleral wrapping with respect to complications, although more posterior implant placement was necessary to avoid exposure in the Dexon-wrapped group. CONCLUSIONS: Surgeons and patients must be prepared for many minor complications when using hydroxyapatite orbital implants, but these can be readily overcome. Dexon mesh wrapping of the implant is recommended to avoid using donor tissue.

Adolescent↗

Hydroxyapatite orbital implant. A light- and electron-microscopic and immunohistochemical study.

OBJECTIVE: This study aimed to characterize the constituents of the ingrown host tissue in explanted orbital coral spheres by means of light electron microscopy and immunohistochemistry and to compare findings at different intervals after implantation. DESIGN AND METHODS: A microscopic retrospective laboratory study of three explanted coral spheres from three different patients was undertaken. The first specimen was an infected hydroxyapatite orbital implant, which was removed after 18.5 months and processed for standard light microscopy and transmission electron microscopy. Immunohistochemistry was performed using vimentin, actin, CD-68, and CD-34 marker. Two other explanted spheres (after 3 weeks and 2.5 months) were examined by light microscopy only, because no fibrovascular ingrowth could be detected. RESULTS: On light microscopy, the pores of the first coral were filled entirely with the fibrovascular tissue. A basophilic line reminiscent of calcium deposition was seen along hydroxyapatite spicules, where it often was associated with newly formed bony lamellae. Similar lines were seen partially in the 2.5-month specimen but not in the 3-week specimen. Immunohistochemistry of the first specimen enhanced visualization of the capillary network when the CD-34 marker was used. The fibrovascular tissue was uniformly vimentin-positive and partially actin-positive. On transmission electron microscopy, typical fibroblasts and myofibroblasts were observed. The latter were separated by thin sheets of banded collagen and formed pseudoepithelial structures. Proliferating vessels often showed high endothelial cells. CONCLUSIONS: The fibrovascular ingrowth contains not only vimentin-positive regular fibroblasts but also actin-positive myofibroblasts. Interaction between the invading tissue and hydroxyapatite structures leads to long-term ossification.

Actins↗

Development of a particle agglutination assay system for detecting Japanese encephalitis virus-specific human IgM, using hydroxyapatite-coated nylon beads.

Japanese encephalitis virus-specific IgM is a reliable indicator for serodiagnosis of Japanese encephalitis. A particle agglutination (PA) assay system was developed to detect anti-Japanese encephalitis virus IgM in human serum samples. The newly developed PA assay consisted of hydroxyapatite-coated nylon beads and V-bottom 96-well microplates. Hydroxyapatite-coated nylon beads were coated with Japanese encephalitis virus antigens. Japanese encephalitis virus antigen-coated, hydroxyapatite-coated nylon beads agglutinated in the IgM-captured wells when anti-Japanese encephalitis virus IgM-positive serum samples were used. A button pattern was formed at the bottom of the wells when anti-Japanese encephalitis virus IgM-negative serum samples were used. Thirty anti-Japanese encephalitis virus IgM-positive serum samples from Japanese encephalitis-confirmed cases were tested by the PA assay. All these serum samples were determined to be Japanese encephalitis virus IgM-positive. IgM titers determined by the PA assay corresponded to those determined by enzyme-linked immunosorbent assay. The titers were consistent in two independent PA assays. These results indicate that the newly developed PA assay is a reliable method for detecting anti-Japanese encephalitis virus IgM in human serum samples and that this assay will be a suitable diagnostic system especially in rural areas of Asia.

Agglutination Tests↗

Hydroxyapatite canal wall reconstruction/mastoid obliteration.

The controversy regarding removal of the posterior external canal wall during mastoid surgery spans many decades. There are inherent advantages and disadvantages to either removing or not removing the canal wall. The operation must be tailored to the patient and his or her unique situation. We describe our experience with external canal wall reconstruction and mastoid obliteration with hydroxyapatite in an effort to derive the best of both philosophies. Hydroxyapatite has been used in 3 different forms including granules, a preformed canal wall prosthesis, and with a block of hydroxyapatite sculpted to fit the individual defect. A total of 36 patients with up to 54-month follow-up are reported. Details of the techniques used, with advantages and pitfalls, are described.

Adolescent↗

Effects of hydroxyapatite particulate debris on the production of cytokines and proteases in human fibroblasts.

Cytokines and proteases are secreted by fibroblasts in response to particulate wear debris, and these proteins are felt to play an important role in the development of osteolysis and implant loosening. Although metallic and polyethlyene debris have been studied extensively, little is known about the cellular responses to hydroxyapatite, despite the wide clinical use of these materials. Therefore, the effects of hydroxyapatite (HA) and hydroxyapatite/beta-tricalciumphosphate (HA/TCP) on cellular proliferation, cytokine gene expression and protein secretion, protease synthesis, and gelatinolytic activity were investigated in human fibroblasts. HA and HA/TCP particles were synthesized, and their effects were compared to the responses elicited by titanium and cobalt chromium. Sample characterization by scanning electron microscopy and Coulter Counter demonstrated that the materials had a mean particle size of less than 10 microm, and all of the particles were compared using the same concentration ranges. Aliquots of particle suspensions were added to human fibroblasts maintained in tissue culture, and dose-response and time-course experiments were performed. Effects of the particles on fibroblast proliferation were assessed, and alterations in cytokine levels were determined by specific enzyme linked immunosorbent assays (ELISA). Cytokines that were evaluated included interleukin-1 (IL-1beta), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha), all of which have been demonstrated to enhance bone resorption and are associated with osteolysis and implant loosening. Gene expression was determined using Northern blot analysis with cytokine-specific probes, while secretion of the proteases collagenase and stromelysin was determined by Western blot analysis. Functional gelatinolytic assay was assessed using zymogram gels. The particles were evaluated in a concentration range from 0.000021 to 0.021 vol%. All of the particles produced increases in cellular proliferation up to 0.0021 vol%, with the largest increases being seen at 0.021 vol% with HA/TCP and titanium. At the highest concentration, both cobalt chromium and HA samples decreased cellular proliferation relative to lower doses, possibly representing cytotoxicity. Hydroxyapatite particles yielded a 30-fold increase in interleukin-6 secretion compared to unstimulated controls, which was also greater than three times the levels produced by cobalt chromium, titanium, or HA/TCP. HA particles also tripled the secretion of IL-1beta at 0.00021 vol%, and doubled TNF-alpha secretion at 0.021 vol%. Addition of conditioned media prepared by incubation of the particles in culture medium in the absence of cells did not alter the secretion of any of the cytokines. Northern blot analysis using IL-6 probes also demonstrated strong increases with HA compared to the other materials, suggesting that the action of the HA particles was at the level of transcription. Secretion of the protease collagenase was increased by all of the samples including HA when compared to unstimulated controls. Stromelysin secretion into the culture medium was decreased by cobalt chromium, but increased by titanium, HA, and HA/TCP. All of the particles including HA increased the gelatinolytic activity of the fibroblasts. These findings demonstrate that HA and HA/TCP particles are capable of stimulating the expression and secretion of cytokines and proteases that enhance bone resorption, and suggest that particulate debris from implants using these coatings may also increase osteolysis and loosening.

Biocompatible Materials↗

Host-bone response to porous-coated cobalt-chrome and hydroxyapatite-coated titanium femoral components in hip arthroplasty. Dual-energy x-ray absorptiometry analysis of paired bilateral cases at 5 to 7 years.

Uncemented porous-coated cobalt-chrome femoral stems have produced satisfactory short-term clinical results, although slightly inferior to the results of cemented total hip arthroplasty. Proximal femoral bone resorption, osteolysis and fibrous ingrowth have been reported with porous-coated stems. Hydroxyapatite-coated stems and titanium stems have been introduced to avoid these findings through improved fixation. Dual-energy x-ray absorptiometry allows quantitative examination of bone density changes after uncemented total hip arthroplasty. This study examines the host-bone response to hydroxyapatite-coated titanium and porous-coated cobalt-chrome stems of identical geometry in three paired bilateral cases at 5 to 7 years. Distinctly different patterns of femoral bone mineral density changes were observed with the two stem designs. The authors conclude that dual-energy x-ray absorptiometry is a promising technique allowing noninvasive analysis of uncemented stem fixation, and that the data from this study suggest improved fixation and stress transfer with hydroxyapatite-coated titanium stems.

Absorptiometry, Photon↗

The effect of Pb(2+) on the structure and hydroxyapatite binding properties of osteocalcin.

Lead toxicity is a major environmental health problem in the United States. Bone is the major reservoir for body lead. Although lead has been shown to impair bone metabolism in animals and at the cellular level, the effect of Pb(2+) at the molecular level is largely unknown. We have used circular dichroism (CD), and a hydroxyapatite binding assay to investigate the effect of Pb(2+) on the structure and mineral binding properties of osteocalcin, a noncollagenous bone protein. The CD data indicate Pb(2+) induces a similar structure in osteocalcin as Ca(2+) but at 2 orders of magnitude lower concentration. These results were explained by the more than 4 orders of magnitude tighter binding of Pb(2+) to osteocalcin (K(d)=0.085 microM) than Ca(2+) (K(d)=1.25 mM). The hydroxyapatite binding assays show that Pb(2+) causes an increased adsorption to hydroxyapatite, similar to Ca(2+), but at 2-3 orders of magnitude lower concentration. Low Pb(2+) levels (1 microM) in addition to physiological Ca(2+) levels (1 mM) caused a significant (40%) increase in the amount of mineral bound osteocalcin as compared to 1 mM Ca(2+) alone. These results suggest a molecular mechanism of Pb(2+) toxicity where low Pb(2+) levels can inappropriately perturb Ca(2+) regulated processes. In-vivo, the increased mineral bound osteocalcin could play a role in the observed low bone formation rates and decreased bone density observed in Pb(2+)-intoxicated animals.

Animals↗

Long-term results of hydroxyapatite-fibrin glue implantation in plastic and reconstructive craniofacial surgery.

The bone tissue formed in orthotopic or heterotopic implants of granular, porous hydroxyapatite and fibrin glue was examined several (2 1/2-8) years after implantation. The results showed distinct ossification in all cases and the functional situation and external appearance were also satisfactory. The reconstituted spongy and compact bone underwent a remodelling process similar to that of normal bone. Most of the hydroxyapatite granules were embedded in the bone tissue; a few were very close to the fibrillar connective tissue of the intertrabecular spaces and were either covered by osteoid-like collagenous borders or were in contact with osteoclast-like giant cells. Even if the results refer only to a few patients, and were obtained from a cross-sectional study, they allow the conclusion to be reached that the implantation of porous hydroxyapatite and fibrin glue leads to the formation of long-lasting bone whose hardness is equal to, or greater than, that of normal bone.

Adult↗

Effect of age and radiation on bone healing adjacent to hydroxyapatite placed in the tibia of rats.

This study investigated the effect of age and radiation on healing after implantation of hydroxyapatite granule in bone. Two groups of 16 male Wistar rats, aged 4 weeks and 2 years were used for this study. Hydroxyapatite particles were placed into the tibia 28 days after the delivery of 15 Gy of irradiation from a Linac source. The results of the present study suggest that an old rat was more vulnerable to the radiation than a young rat. It seemed that age might also be an important factor in the prognosis of the implanted hydroxyapatite in irradiated bone.

Age Factors↗

Hydroxyapatite orbital implant exposure in children.

PURPOSE: Hydroxyapatite orbital implants are buried implants that may be integrated into the overlying prosthesis after enucleation. We report problems encountered using these implants during a 14-year period in a pediatric population. METHODS: Retrospective analysis of a pediatric population from 1987 through 2001. RESULTS: Indications for enucleation (N = 19) included retinoblastoma (n =17), persistent hyperplastic primary vitreous (n =1), and painful blind eye (n =1). Conjunctival erosion (36.84%) and consequent implant exposure (15.70%) were the main problems identified in this study. There were no cases of orbital infection. Management included resuturing and scleral patching. CONCLUSION: Conjunctival erosion of hydroxyapatite implants contributed to significant morbidity in 19 children who underwent enucleation and hydroxyapatite orbital implant.

Child, Preschool↗

Thermodynamics of statherin adsorption onto hydroxyapatite.

Statherin is a salivary protein that inhibits the nucleation and growth of hydroxyapatite crystals in the supersaturated environment of the oral cavity. The thermodynamics of adsorption of statherin onto hydroxyapatite crystals have been characterized here by isothermal titration calorimetry and equilibrium adsorption isotherm analysis. At 25 degrees C, statherin adsorption is characterized by an exothermic enthalpy of approximately 3 kcal/mol that diminishes to zero at approximately 25% surface coverage. The initial heat of statherin adsorption increases with temperature, displaying a positive heat capacity change of 194 +/- 7 cal K(-)(1) mol(-)(1) at 25 degrees C. The heat of adsorption during this initial phase is strongly dependent on the buffer species, and from the differential heats of buffer ionization, it can be calculated that approximately one proton is taken up by the crystal or protein upon adsorption. The free energy of adsorption is dominated at all coverages by a large positive entropy (>or=23 cal K(-)(1) mol(-)(1)), which may be partially due to the loss of organized water that hydrates the protein and the mineral surface prior to adsorption. These results are interpreted using a two-site model for adsorption of statherin onto the hydroxyapatite crystals.

Adsorption↗

Biomimetic growth of hydroxyapatite on gelatin films doped with sodium polyacrylate.

Gelatin films were used as biomimetic substrates for the nucleation of hydroxyapatite from simulated body fluid (SBF). Stretching and presence of sodium polyacrylate appear to be essential factors for the specific nucleation and growth of hydroxyapatite crystals inside the films. After soaking in 1.5SBF for periods longer than 4 days, all the films display a completely calcified surface. However, the spherical aggregates on the film surfaces do not give any X-ray diffraction effect and exhibit a low Ca/P molar ratio, typical of amorphous calcium phosphate. The ordered deposition of crystalline hydroxyapatite has been verified to take place only in stretched polyacrylate--gelatin films. The crystals grow as tablets about 2 microns thick among the gelatin layers, with their crystallographic c-axes preferentially oriented parallel to the direction of orientation of the collagen molecules, thus resembling the parallel orientation of apatitic crystals and collagen fibrils in calcified biological tissues.

Acrylic Resins↗

Studies on the mechanisms of lead immobilization by hydroxyapatite.

The sorption of lead by synthetic hydroxyapatite (HA) from solutions containing Pb2+ initial concentrations up to 1770 mg L(-1) was studied. X-ray diffractometry (XRD) associated with Rietveld methodology for refining the spectra pattern was used in order to characterize the mechanisms of lead uptake. It is shown that the dissolution of hydroxyapatite is followed by the formation of a solid solution, Pb(10-x)Ca(x)(PO4)6(OH)2, with Pb ions mostly occupying Ca(II) sites. The Ca/Pb molar ratio of this solid solution decreases continuously until it reaches the structure of a pure hydroxypyromorphite. The cell parameters and the crystallite mean size behavior of both mineral phases reinforce the hypothesis that hydroxypyromorphite, PbHA, formation is the end of a process in which Pb(10-x)Ca(x)(PO4)6(OH)2 crystallites are continuously dissolved and recrystallized producing crystals with lower calcium content. Combination of Inductively Coupled Plasma spectrometry (ICP), chemical analysis, and XRD results permitted the conclusion that lead ions are not completely immobilized by precipitating Pb(10-x)Ca(x)(PO4)6(OH)2. Additional surface mechanisms also contribute to Pb2+ uptake. During Pb2+ sorption process, pH variations of the solution phase showed a more complex pattern than previously reported. Contribution of surface mechanisms, in addition to the hydroxyapatite dissolution, could explain this behavior.

Biocompatible Materials↗

Direct formation of nanophase hydroxyapatite on cathodically polarized electrodes.

Ultrafine-grained, nanophase coatings of hydroxyapatite were synthesized by electrocrystallization from dilute electrolytes ([Ca]=6.1 x 10-4 M, [phosphate]=3.6 x 10-4 M) at pH values comparable with the biological pH. At these comparatively low supersaturations, hydroxyapatite is shown to be precipitated without the formation of a precursor phase. A description of the sequence of events occurring at the electrode-electrolyte interface is given to explain the mechanism involved in the direct formation of nanophase hydroxyapatite on polarized electrodes.

Journal Article↗

alpha-Tricalcium phosphate hydrolysis to hydroxyapatite at and near physiological temperature.

The kinetics of hydroxyapatite (HAp) formation by direct hydrolysis of alpha-tricalcium phosphate (alpha-TCP) [alpha-Ca(3)(PO(4))(2)] have been investigated. Transformation kinetics were examined for reactions at 37 degrees C, 45 degrees C and 56 degrees C by isothermal calorimetric analysis. Setting times and morphologies of the resultant HAp were found to be strongly dependent on reaction temperature. XRD analysis accompanied by FTIR confirmed that phase pure calcium-deficient hydroxyapatite (CDHAp) [Ca(10-x)(HPO(4))(x)(PO(4))(6-x)(OH)(2-x)] was formed. Complete reaction occurs within 18, 11, 6.5 h at 37, 45 and 56 degrees C, respectively. The extent of HAp formation differs for particulate slurries and pre-shaped forms of reactant alpha-TCP. Formation of hydroxyapatite in pre-formed pellets was hindered due to limited water penetration, but enhanced with the presence of NaCl as a pore generator. Regardless of the precursor characteristics and temperature, HAp formation is characterized by an initial period of wetting of the alpha-TCP precursor, an induction period and a growth period during which the bulk transformation to HAp occurs. The microstructures of the resultant HAp at all temperatures were generally similar and are characterized by the formation porous flake-like morphology. Microstructural coarsening was observed for the CDHAp formed above the physiological temperature. The hardening generated by the hydrolysis reaction was demonstrated using diametrical compression tests. The original tensile strength of 56% dense alpha-TCP increased from 0.70+/-0.1 MPa to 9.36+/-0.4 MPa after hydrolysis to CDHAp at 37 degrees C, corresponding to a density of 70%.

Journal Article↗

Interdiffusion in short-fibre reinforced hydroxyapatite ceramics.

Sintering in air and hot isostatic pressing are production methods regarded as being capable of producing fibre-reinforced hydroxyapatite ceramics for biomedical applications. These composites may have the advantage of improved mechanical properties and be suitable for applications in areas where there are significant levels of load on the material. The use of pure hydroxyapatite is restricted to those free of dynamical load. Obtaining improved mechanical strength is a question of the bond between the matrix phase and the fibre-reinforcement phase. However, a chemical bond between both phases, indicated by large diffusion zones, might lead to the dehydration of the hydroxyapatite leading to undesired tricalcium phosphate in the matrix resulting in a weakening of the mechanical and biological stability of the composites. Composites with three fibre types, alumina, 316L-stainless steel and titanium were prepared and sintered in air or hot isostatically pressed. A reaction zone was noted around the titanium and stainless steel fibres, but not around the alumina fibres. The reaction zone was larger for stainless steel than titanium. Hot isostatic pressing also reduced the reaction zone markedly compared to sintering in air.

Journal Article↗

Diaphyseal fractures treated by polylactide and hydroxyapatite pins. Experimental study in rat.

In order to develop a biodegradable interlocking nail for fracture fixation, polylactic acid (PLA) pins and hydoxyapatite pins were implanted in the femoral bone in rats. A distal fracture was performed. The union and the tissue reaction to PLA and hydroxyapatite versus stainless steel rods were studied after 15 days, 1, 2 and 6 months implantation. Metal and PLA pins induced a union. Hydroxyapatite pins (Ossatite) did not prevent callus formation, but did not lead to consolidation in all cases because of weakness of the gelatin matrix binding the apatite particles together. PLA and stainless steel pins induced the same union and a similar tissue reaction during the studied implantation of 6 months. The biocompatility of Ossatite is satisfactory and the osteo-inductive properties of hydroxyapatite was confirmed. With injectable Ossatite, we could not obtain rat femoral fracture consolidation. We can confirm good biomaterial tolerance in bone which contrasts with important soft tissue reactions. Use of such material should be carefully limited to filling intra-osseous cavities.

Journal Article↗