Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “GLASSES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42Linked to original sources

Treatment of tooth fracture by medium energy CO2 laser and DP-bioactive glass paste: compositional, structural, and phase changes of DP-bioglass paste after irradiation by CO2 laser.

Nowadays, fractured teeth are difficult to treat effectively. Currently, root fractures are usually treated by root amputation, hemisection or tooth extraction. If the fusion of tooth fracture by laser were possible, it would offer a different therapy to repair fracture teeth. We tried to use a developed DP-bioactive glass paste to fuse or bridge the tooth crack line by a medium energy continuous-wave CO2 laser. The study is divided into three parts: (1) The compositional and structure changes in tooth enamel and dentin after laser treatment; (2) The phase transformation and recrystallization of DP-bioactive paste during exposure to the CO2 laser; (3) The thermal interactions and bridge mechanism between DP-bioactive glass paste and enamel/dentin when they are subjected to CO2 laser. The present report will focus on the second part that will examine the changes of laser-exposed DP-bioactive glass paste by means of X-ray diffractometer (XRD), Fourier transforming infrared spectroscopy (FTIR), differential thermal analysis/thermogravimetric analysis (DTA/TGA), and scanning electron microscopy (SEM). From the study, we could find that the temperature increase due to laser irradiation is greater than 900 degrees C and that the DP-bioactive glass paste could be melted in a short period of time after irradiation. In the study, we successfully developed a DP-bioactive glass paste which could form a melting glass within seconds after exposure to a medium energy density continuous-wave CO2 laser. The paste will be used in the near future to bridge the enamel or dentin surface crack by the continuous-wave CO2 laser.

Carbon Dioxide↗

Comparison of usefulness of three types of artificial substrata (glass, wood and plastic) when studying settlement patterns of periphyton in lakes of different trophic status.

Usefulness of three types of artificial substrata (glass, wood and plastic) was tested when studying settlement patterns of periphyton in lakes of different trophic status. Strictly eu-, meso- and oligotrophic lakes in central Sweden were chosen as objects of the study. Glass slides, glass tubes, pieces of plastic (PVC) and pieces of wood of similar dimensions were placed for 9 weeks in July-August vertically 3 cm above bottom at a total depth of ca. 30 cm. Substrata were located at well-illuminated places without any other submerged objects (like macrophytes and stones), which could potentially affect colonisation patterns by algae. Periphyton communities, which colonised both the glass tubes and the pieces of wood tested, were specific enough to enable a clear classification of the lakes studied in eu-, meso- and oligotrophic. Glass tubes turned out to be the most favourable substratum when investigating settlement patterns of periphyton in this study. Although also colonised by periphytic species, wood did not support the same diversity and abundance of species as glass did. No algae were detected on the plastics studied. The plastics were covered entirely by a slime layer of bacteria. It is discussed if the nature of plastics could have some inhibitory effects on algal growth or the slime layer itself may have prevented settlement of algal spores.

Bacteria↗

Pulmonary response of hamsters to fibrous glass. Clearance and morphology after a single intratracheal instillation.

In a one-year serial sacrifice study 10 mg glass fibres (length, 95% alpha 20 microns, 89% alpha 12 microns, 58% alpha 5 microns and 25% alpha 2 microns; diameter, 88% alpha 1.0 micron, 60% alpha 0.5 micron and 31% alpha 0.25 micron) suspended in 0.2 ml saline solution were administered to Syrian golden hamsters by a single intratracheal instillation to determine the clearance of the glass fibres from the lungs and to examine their effects on the lungs using light and electron microscopy. The clearance was rather efficient with a half-time of about 3 months. Coating and corrosion of glass fibres were sporadic findings. A violent focal acute pneumonitis was evoked by the glass fibres and was followed by excessive accumulations of alveolar macrophages often loaded with glass fibres. Thereafter, "silicotic granulomas" developed which were seen as clusters of tightly packed iron-positive macrophages containing glass fibres. These granulomas were surrounded by a layer of alveolar epithelium, and were by the end of the study the predominant lesion in otherwise normal lungs.

Animals↗

Mineralization in bovine dentin adjacent to glass-ionomer restorations.

OBJECTIVES: To assess the uptake of fluoride as well as the increase in mineralization by bovine dentin after restoring an experimentally made cavity with conventional glass-ionomer cement or a polyacid resin composite. METHODS: Cylindrical cavities were prepared on the labial root surfaces in bovine dentin. The cavities were restored with the test material. The restored teeth were individually suspended in distilled water at 37 degrees C for 30 days. The teeth were sectioned and the superficial dentin cavity walls were analyzed for fluoride, calcium, and phosphorus by an EPMA device. The effects of the different fluoride-releasing materials on the hardness of the dentin were determined by indentation (20-microm intervals below the filled surface into the underlying sound dentin from the surface to a depth of 100microm). RESULTS: Conventional glass-ionomer cement had a significant effect on fluoride uptake. In addition, the calcium and phosphorus scan revealed the elevation of calcium and phosphorus levels in a deeper zone corresponding to the locations of the fluoride uptake at the surface of axial wall. However, the polyacid resin composite did not exhibit a zone of calcium and phosphorus elevation. The average dentin hardness under conventional glass-ionomer cement in the studied five distances ranged from 84.3 to 61.3KHN, however, that of the polyacid resin composite ranged from 62.5 to 64.9KHN. Analysis of variance for these data demonstrated a significant difference in hardness between the 20-microm depth and the other depths (P<0.01, ANOVA Fisher's PSLD). CONCLUSION: The present paper indicates that the fluoride penetrated deeper into the dentin with conventional glass-ionomer cement than the polyacid resin composite. Conventional glass-ionomer cement had a significant effect on fluoride uptake. In addition, hypermineralization occurred within the superficial dentin cavity wall region of conventional glass-ionomer cement.

Analysis of Variance↗

The effect of a resin-modified glass ionomer restorative material on artificially demineralised dentine caries in vitro.

OBJECTIVES: Recurrent caries is one of the most common reasons for the replacement of restorations. One method of reducing the frequency of this problem may be by using fluoride-releasing restorative materials. The aim of this in vitro study was to evaluate the progression of artificial lesions around resin-modified glass ionomer (Vitremer) restorations placed in root surfaces. Class V cavities were prepared on the mesial and distal surfaces of 28 human premolar teeth. Artificial carious wall lesions were created in all cavities. The root of each tooth was then hemisected through the middle of the two cavities, before being restored with either the glass ionomer or amalgam, while the opposing cavities on the same root portion were varnished as negative controls. Forty-eight specimens were pH-cycled in remineralising and demineralising solutions for 20 h and 4 h, respectively, each day for 4 weeks, whilst in a smaller control group of eight specimens, the demineralising solution was replaced with deionised water. Mineral changes in the carious lesions were evaluated using contact microradiography. RESULTS: Results showed that varying degrees of subsurface demineralisation and remineralisation were evident, with a laminated appearance in lesions adjacent to the glass ionomer. There was higher remineralisation in the glass ionomer-filled cavities compared with the amalgam-filled cavities. In the water-cycled group, glass ionomer showed an increase in mineral content (p < 0.05), while no changes were observed in the amalgam-filled cavities. CONCLUSIONS: This model has shown that glass ionomer has a greater potential than amalgam for remineralisation of artificially created wall lesions within an acidic environment.

Bicuspid↗

A glass compensator filter to improve breast image quality in radiation therapy simulation.

PURPOSE: To improve the image quality of simulation films in tangential radiotherapy for breast cancer, we have designed a new compensator filter for the variation of breast contour using high-density-glass material. METHODS AND MATERIALS: The measurements and analyses of the body contour were done using CT scans, taken in the treatment position, of 20 breast cancer patients. The maximum tissue deficit that needed to be compensated for was 8 cm, and the authors fabricated the compensator system using high-density-glass material to maintain transparency. The glass compensator can be attached to the accessory mount of the simulator head and its position can be easily adjusted according to breast shape and position. The image qualities of simulation films taken with and without the glass compensator in tangential breast radiotherapy field were compared and the film densitometry was performed using the humanoid phantom. RESULTS: Using this compensator system, the overall image quality improved, resulting in enhanced contrast and resolution of the breast simulation image. The delineator wires for the beam margins were also well depicted, and the surgical clips within the breast tissue can be easily demonstrated. The film densitometry resulted in much less saturation over the breast tissue when using the glass compensator. CONCLUSION: Using the glass compensator system, the geographical miss may be reduced with the virtue of the improved image quality.

Breast Neoplasms↗

Effect of time on the shear bond strength of glass ionomer and composite orthodontic adhesives.

The purpose of this study was to compare the effects of time on the shear bond strength of a resin-reinforced glass ionomer and a composite adhesive system specifically (1) within half an hour after bonding the bracket to the tooth and (2) at least 24 hours from the time of bonding when the adhesive has achieved most of its bond strength. Ninety-one freshly extracted human molars were collected and stored in a solution of 0.1% (weight/volume) thymol. The teeth were cleaned and polished. The teeth were randomly separated into four groups: Group I, glass ionomer adhesive debonded within 30 minutes from initial bonding; Group II, glass ionomer adhesive debonded after 24 hours immersion in deionized water at 37 degrees C; Group III, composite adhesive debonded within 30 minutes from initial bonding; Group IV, composite adhesive debonded after 24 hours immersion in deionized water at 37 degrees C. The results of the analysis of variance comparing the 4 experimental groups (F = 59. 3) indicated the presence of significant differences between the 4 groups (P =.0001). In general, the shear bond strengths were significantly greater in the 2 groups debonded after 24 hours. This was true for both the resin-modified glass ionomer (x = 8.8 +/- 3.6 MPa) and the composite (x = 10.4 +/- 2.8 MPa) adhesives. On the other hand, the shear bond strengths were significantly lower in the 2 groups debonded within 30 minutes of their initial bonding. The bond strength of the resin-modified glass ionomer adhesive (x = 0.4 +/- 1.0 MPa) was significantly lower than that for the composite (x = 5.2 +/- 2.9 MPa) adhesive. The present findings indicated that the resin reinforced glass ionomer adhesive has a significantly lower initial bond strength but increased more than 20-fold within 24 hours. In comparison, the composite adhesive has a significantly larger initial bond strength that doubled within 24 hours. The clinician needs to take these properties into consideration when ligating the initial arch wires.

Acrylic Resins↗

Is glass visible on plain radiographs? A cadaver study.

Eighteen randomly selected pieces of nonleaded glass from a collection of 30 pieces from broken bottles of four known color types found on the streets of Houston were sorted into four sets with one control. The purpose of this study was to determine if regular glass is visible on plain radiographs and whether color, location, or volume of these fragments had any effect on the detection of nonleaded glass. These sets were then placed into a fresh-frozen cadaver foot and ankle with a history of insulin-dependent diabetes and peripheral vascular disease. This foot was radiographed utilizing four standard foot projections. Five examiners read these five sets of radiographs twice and recorded the number seen. Overall sensitivity for all of the examiners was 90% with an overall false-positive rate of 10%. Intraobserver and interobserver Pearson's correlation coefficients showed that there was reliability between the first and second readings and between observers. The authors concluded that regular nonleaded glass is radiographically visible and that factors such as color and location of the glass have no effect on its detection, while a volume of less than 15 mm3 may have an effect on the detection of glass.

Cadaver↗

Thermal properties and optical transition probabilities of Tm3 + doped TeO2-WO3 glass.

Glasses with the composition of (1 - x)TeO2 + (x)WO3, where x = 0.15, 0.25 and 0.3 were prepared and, their thermal and absorption measurements were carried out. Differential thermal analysis (DTA) curves taken in the 23-600 degrees C temperature range with a heating rate of 10 degrees C/min reveal a change in the value of the glass transition temperature, Tg, while crystallization was not observed for the glasses containing a WO3 content of more than 15 mol%. All the glasses were found to be moisture-resistant. The absorption bands corresponding to the absorption of the 1G4, 3F2, 3F3 and 3F4, 3H5 and 3H4 levels from the 3H6 ground level of the Tm3+ ion were observed in the optical absorption spectra. Integrated absorption cross-sections of each band except that of 3H5 level was found to vary with the glass composition. Judd-Ofelt analysis was carried out for the samples doped with 1.0 mol% Tm2O3. The omega2 parameter shows the strongest dependence on the host composition and it increases with the increasing WO3 amount. The value of omega4 increases rather slowly while the value of omega6 is practically independent of the composition. The strong dependence of the parameter omega2 indicates that this parameter is related to the structural change and the symmetry of the local environment of the Tm3+ ions in this glass.

Differential Thermal Analysis↗

Libration motion of guest spin probe molecules in organic glasses: CW EPR and electron spin echo study.

Echo-detected (ED) EPR spectra of nitroxide spin probes dissolved in glassy materials provide evidence that guest molecules in these media undergo fast librational motion. Theory of spin relaxation of a librating molecule is presented. The mean squared amplitude, , of this motion which can be derived from continuous wave (CW) EPR spectral splitting is found to depend linearly on temperature in the low temperature region. This may be ascribed to thermal harmonic vibrations. The slope of the linear dependence varies from glass to glass and seems to correlate with the strength of the intermolecular bonds and with a degree of the fragility of the glass. Above the glass transition temperature increases sharply. Different applications are discussed: study of molecular properties of glass, intracellular glass formation in plant tissues, structural investigations.

Electron Spin Resonance Spectroscopy↗

AFM study of the behavior of polystyrene and glass particles during the electrodeposition of copper.

In this paper, the behavior of polystyrene and glass particles on a copper electrode during the electrodeposition of copper was studied using an atomic force microscope (AFM). Polystyrene or glass particles glued to the tip of the AFM cantilever were kept in contact with the surface of the electrode. The surface forces between the polystyrene or glass particle and the copper electrode were measured before, during, and after electrodeposition. These experiments revealed that glass particles do not make contact with the electrode, probably due to the repulsive hydration force. Polystyrene particles, on the other hand, make contact with the electrode, due to the attractive hydrophobic force. The AFM experiments were correlated with sedimentation co-deposition experiments of polystyrene and glass particles with copper. It was found that 80% of the polystyrene particles added to the plating solution incorporated with copper, while only 0.25% of the glass particles co-deposited under the same conditions.

Copper↗

Superlow fouling sulfobetaine and carboxybetaine polymers on glass slides.

This work describes the superlow fouling properties of glass slides grafted with zwitterionic polymers to highly resist the adsorption of proteins and the adhesion of mammalian cells. Glass slides were first silanized using 2-bromo-2-methyl-N-3-[(triethoxysilyl)propyl]propanamide (BrTMOS). Two zwitterionic polymers, poly(sulfobetaine methacrylate) (polySBMA) and poly(carboxybetaine methacrylate) (polyCBMA), were then grafted from the silanized glass substrates using the atom-transfer radical polymerization (ATRP) method. X-ray photoelectron spectroscopy (XPS) was used to analyze the surfaces of the silanized glass substrates and the substrates grafted with the polymers. An enzyme-linked immonosobrbent assay (ELISA) using polyclonal antibodies was used to measure fibrinogen adsorption on these surfaces. The surfaces with polySBMA or polyCBMA layers were shown to reduce fibrinogen adsorption to a level comparable with that of adsorption on poly(ethylene glycol)-like films. Bovine aortic endothelial cells (BAECs) were seeded on these surfaces. The attachment and spreading of the cells were observed only on unpolymerized glass surfaces. This work further demonstrates that zwitterionic polymers highly resist nonspecific protein adsorption and cell adhesion and provides an effective method to modify glass slides or other oxide surfaces to achieve superlow fouling.

Adsorption↗

Complexities in ETS-domain transcription factor function and regulation: lessons from the TCF (ternary complex factor) subfamily. The Colworth Medal Lecture.

The ETS-domain transcription factor family can be divided into a series of subfamilies. Elk-1 represents the founding member of the ternary complex factor (TCF) subfamily. By focusing on the TCF subfamily, we can demonstrate the complexities that exist in the function and regulation of ETS-domain transcription factors. This article focuses on Elk-1 in detail and summarizes the functions of other TCFs. The key themes covered include the domain structure of the TCFs, the mechanisms of complex formation with serum response factor, regulation of TCFs by mitogen-activated protein kinase cascades, and transcriptional regulatory properties of the TCFs. Finally, the emerging role of the TCFs in vivo is discussed. A picture is developing indicating that, while these proteins exhibit significant sequence and functional conservation, key differences in their structure and regulation are being identified which may relate to unique functions of these proteins in vivo.

Amino Acid Sequence↗

Repair of denture base resin using woven metal and glass fiber: effect of methylene chloride pretreatment.

STATEMENT OF PROBLEM: A durable repairing system for denture base fracture is desired to avoid recurrent fracture. Purpose. This study evaluated the strength and modulus of elasticity of repaired acrylic specimens reinforced with various processes. MATERIAL AND METHODS: Transverse strength and modulus of elasticity of repaired acrylic denture base specimens were evaluated with a 3-point bending test and compared with a heat-polymerized control. Autopolymerizing acrylic resin was used with woven metal fiber and glass fiber with and without methylene chloride surface treatment (n = 6 per group). The specimens were cut in half and fixed in a metal mold to obtain a space for placing the repairing resin. A cavity was prepared when metal or glass fiber was used. All specimens were stored in 37 degrees C distilled water for 48 hours before the test. All data were statistically analyzed with 1-way ANOVA, and differences among groups were analyzed with Fisher test (P< or =.05). RESULTS: The mean value of the transverse strength for the control was 87.2 MPa. The specimens repaired by glass fiber with methylene chloride surface treatment exhibited the highest transverse strength (96.8 MPa), which was significantly higher than that of the control (P< or =.05). The elastic modulus of the specimens repaired by glass fiber with methylene chloride surface treatment (4189.3 MPa) was significantly greater than that of the control (2683.7 MPa) at a 95% level of confidence. The values of transverse strength and elastic modulus were highest when the surface treatment was combined with a reinforcing glass fiber. CONCLUSION: Reinforcement with glass fiber and methylene chloride pretreatment produced transverse strength and a modulus of elasticity higher than the control.

Acrylic Resins↗

Effect of various surface protections on the margin microleakage of resin-modified glass ionomer cements.

STATEMENT OF PROBLEM: Because conventional glass ionomer cements are moisture sensitive, a surface coating is recommended during the initial setting stage. It is unknown whether resin-modified glass ionomer cements also need surface protection. PURPOSE: This study investigated the effect of various surface protections on microleakage with Class V resin-modified glass ionomer restorations. MATERIAL AND METHODS: Forty extracted molars with buccal and lingual Class V cavity preparations were restored with a resin-modified glass ionomer (Fuji II LC). The occlusal margin of each restoration was on enamel and the cervical margin on dentin. After immediate finishing and polishing, the teeth were divided into 4 groups according to the following surface protection treatments: group I, unprotected; group II, Fuji varnish; group III, resin adhesive; and group IV, acid etching and resin adhesive. After these procedures, all teeth were stored in isotonic saline for 24 hours, thermocycled 1500 times at 5 degrees C to 60 degrees C, and soaked in dye solution for 24 hours. The teeth then were longitudinally sectioned and observed under a stereomicroscope. The degree of dye penetration was recorded and analyzed with the Kruskal-Wallis and Mann-Whitney tests (P<.05) RESULTS: None of the 4 groups demonstrated complete margin sealing at either the occlusal or cervical margins. Groups II and III displayed the least microleakage at cervical margins; a significant difference existed between groups I and III (P=.034). Compared with the other 3 groups, group IV showed significantly greater microleakage at the cervical margins. CONCLUSION: Although resin-modified glass ionomers can be finished immediately, they remain moisture sensitive. Within the limitations of this study, the results suggest that resin adhesive should be used as a surface protection to reduce margin microleakage of resin-modified glass ionomer restorations.

Acid Etching, Dental↗

Glass encapsulation of flavours with chemically modified starch blends.

Carrier compositions based on blends of various octenylsuccinic acid anhydride (OSAN)-modified starches were utilized in the glass encapsulation of flavours by means of melt extrusion and spray drying. Dextrinized, acid and enzymatically hydrolysed OSAN starches were used in various combinations. Processing parameters were optimized for desirable physical chemical and functional properties of the encapsulating compositions. One key property in the optimization of the extrusion process was setting rate of the exiting melt into a glass. Glassy states of identical spray-dried and extruded compositions were characterized by MDSC for glass transition temperature(s), heat capacity change and enthalpy relaxation. Flavour retention, surface flavour, moisture, particle density and flavour particle size distribution were also measured and compared for the extruded and spray-dried compositions. In addition, elastic recovery and caking were evaluated for extruded compositions. The glass transition parameters were correlated directly or indirectly with most of the physical properties of encapsulating compositions, especially flavour retention, surface flavour and caking. In extruded compositions, two phases were revealed by the presence of two glass transitions, whereas spray-dried compositions showed only one broad glass transition.

Drug Compounding↗

Modeling the "glass" transition in proteins.

A model of a protein as a disordered system of identical spherical particles (which imitate protein side chains) interacting with each other via a repulsive soft sphere potential U(r) infinity r(-beta) is constructed. The particles undergo the conformational motion (CM) within their own harmonic conformational potentials around some mean equilibrium positions ascribed by the tertiary structure of the protein. A first principles calculation of the positional correlation functions for the CM is carried out. The general analysis is exemplified by the case in which the mean equilibrium positions of the particles form a cubic tightly-packed (face- centered) lattice (each particle has 12 nearest neighbors) with the step b(hydr) =6.6 A (the average distance between the centers of mass of hydrated protein subunits). The model yields dramatic slowing down of the relaxation with the decrease of temperature followed by a sharp glass transition at some crossover temperature T(c) < 200 K. At the transition the liquid-like dynamic behavior (the correlation functions tend to zero with time) is altered by the glass-like one (the correlation functions tend with time to some non-zero limit). In the liquid-like region above the crossover temperature the relaxation exhibits distinct alpha-process following the beta-one. The glass transition results from the interaction of the particles. Thus the model suggests that namely direct interactions of the fragments of protein structure rather than protein-solvent interactions are the origin of the phenomenon of the glass transition. The known increase of T(c) up to 300 K at dehydration of the protein is attributed to the known concomitant compression of the globule upon drying by about 4-6% so that positions of individual atoms displace by about 0.6 A (modeled by the decrease of the step of the lattice b by 0.6 A so that b(dehydr)=6 A). The model suggests that the solvent influences the phenomenon of the glass transition indirectly determining the tertiary structure of the protein rather than via own freezing. In the model the transition from the liquid-like dynamic behavior to the glass-like one can be obtained even in a cluster containing a few particles. Thus the results of the model can be considered as an argument in favor of the point of view that the transition to the glassy behavior can take place for a very small domains of the protein comprising only several constituting fragments of its structure. The model predicts that for the dehydrated protein the alpha-relaxation process is strongly repressed.

Glass↗

Covalent attachment of DNA oligonucleotides to glass.

A method for synthesizing DNA directly on glass is presented. The process is based on pretreatment of glass with boiling hydrochloric acid, thus exposing the hydroxyl groups of the glass. Phosphite-triester chemistry was used to directly attach the first nucleotide to a glass plate via a covalent bond between the hydroxyl group of the glass and the phosphate group of the protected deoxyribonucleotide. Standard molecular biology procedures, such as ligation and restriction digest, were efficiently performed on the glass synthesized oligonucleotide, with the added benefit of extreme ease of handling.

Biotechnology↗