Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42Linked to original sources

Increased power generation in a continuous flow MFC with advective flow through the porous anode and reduced electrode spacing.

The maximum power generated in a single-chamber air-cathode microbial fuel cell (MFC) has previously been shown to increase when the spacing between the electrodes is decreased from 4 to 2 cm. However, the maximum power from a MFC with glucose (500 mg/L) decreased from 811 mW/ m2 (R(ex) = 200 omega, Coulombic efficiency of CE = 28%) to 423 mW/m2 (R(ex) = 500 omega, CE = 18%) when the electrode spacing was decreased from 2 to 1 cm (batch mode operation, power normalized by cathode projected area). This decrease in power was unexpected as the internal resistance decreased from 35 omega (2-cm spacing) to 16 omega (1-cm spacing). However, providing advective flow through the porous anode toward the cathode substantially increased power, resulting in the highest maximum power densities yet achieved in an air-cathode system using glucose or domestic wastewater as substrates. For glucose, with a 1-cm electrode spacing and flow through the anode with continuous flow operation of the MFC, the maximum power increased to 1540 mW/m2 (51 W/m3) and the CE increased to 60%. Using domestic wastewater (255 +/- 10 mg of COD/L), the maximum power density was 464 mW/m2 (15.5 W/m3; CE = 27%). Although flow through the anode could lead to plugging, especially for particulate substrates such as domestic wastewater, the system was operated using glucose for over 42 days without clogging. These results show that power output in this air-cathode single-chamber MFC can be increased by reducing the electrode spacing if the reactors are operated in continuous flow mode with advective flow through the anode toward the cathode.

Electrochemistry↗

Electrorepulsion versus electroosmosis: effect of pH on the iontophoretic flux of 5-fluorouracil.

PURPOSE: To delineate the contributions of electrorepulsion and electroosmosis to the iontophoretic flux of 5-FU across porcine skin in vitro. Also, the isoelectric point (pI) of the skin model was determined. METHODS: The electrotransport of 5-FU, anode-to-cathode ("anodal") and cathode-to-anode ("cathodal") was determined as a function of the pH of the electrolyte bathing the skin. RESULTS: At pH 8.5, the drug (pKa approximately 8) is negatively charged and "cathodal", viz. electrorepulsive, transport is much greater than that in the opposite direction. At pH 7.4, where approximately 25% of 5-FU is charged, electrorepulsive and electroosmotic ("anodal") fluxes are balanced. Decreasing the pH to 6, and then 5, reduces the percentage of ionized 5-FU such that "anodal" electroosmosis dominates across the negatively-charged membrane. But, at pH 4, "anodal" and "cathodal" fluxes are again equal suggesting neutralization of the skin (i.e., pI approximately 4). This is confirmed at pH 3, where "cathodal" electroosmosis dominates across the now net-positively charged barrier. CONCLUSIONS: Electrotransport is sensitive, mechanistically, to the properties of the permeant and of the skin; interactions of, for example, the drug or constituents of a formulation, that alter the barrier's net charge, can affect iontophoretic delivery. The pI of porcine ear skin is approximately 4.

Administration, Cutaneous↗

Epidural electrical stimulation of posterior structures of the human lumbosacral cord: 2. quantitative analysis by computer modeling.

OBJECTIVES: Analysis of the computed recruitment order of an ensemble of ventral and dorsal root fibers should enlighten the relation between the position of a bipolar electrode and the observed order of muscle twitches. MATERIAL AND METHODS: Thresholds of selected spinal root fibers are investigated in a two step procedure. First the electric field generated by the electrodes is computed with the Finite Element Method. In the second step the calculated voltage profile along each target neuron is used as input data for a cable model. For every electrode position the electrical excitability is analyzed for 12 large diameter ventral and dorsal root fibers of the second and fourth lumbar and first sacral segment. The predictions of the neural responses of any target fiber are based on the activating function concept and on the more accurate computer simulations of the electrical behavior of all nodes and internodes in the vicinity of the electrode. RESULTS: For epidural dorsal lumbosacral spinal cord stimulation we found the following rules. (i) The recruitment order of the spinal roots is highly related to the cathode level. (ii) Dorsal root fibers have the lowest threshold values, ventral root fibers are more difficult to excite and dorsal columns are not excitable within the clinical range of 10 V. (iii) For a cathode close to the level of the spinal cord entry of a target fiber thresholds are lowest and spike initiation is expected at the border between cerebrospinal fluid and white matter; excitation of L4 roots is not possible with 210 micros/10 V pulses when cathode is more than 2.2 cm cranial to their entry level (1.5 cm for S1 roots; standard data). (iv) Cathodes positioned (essentially) below the entry level cause spike initiation close to the cathode, in a region where the fibers follow the descending course within the cerebospinal fluid. (v) At rather low stimulation voltage twitches are expected in all investigated lower limb muscles for cathodes below L5 spinal cord level. CONCLUSIONS: Our simulations demonstrate a strong relation between electrode position and the order of muscle twitches which is based on the segmental arrangement of innervation of lower limb muscles. The proposed strategy allows the identification of the position of the electrode relative to spinal cord segments.

Electric Stimulation↗

Electric field-directed fibroblast locomotion involves cell surface molecular reorganization and is calcium independent.

Directional cellular locomotion is thought to involve localized intracellular calcium changes and the lateral transport of cell surface molecules. We have examined the roles of both calcium and cell surface glycoprotein redistribution in the directional migration of two murine fibroblastic cell lines, NIH 3T3 and SV101. These cell types exhibit persistent, cathode directed motility when exposed to direct current electric fields. Using time lapse phase contrast microscopy and image analysis, we have determined that electric field-directed locomotion in each cell type is a calcium independent process. Both exhibit cathode directed motility in the absence of extracellular calcium, and electric fields cause no detectable elevations or gradients of cytosolic free calcium. We find evidence suggesting that galvanotaxis in these cells involves the lateral redistribution of plasma membrane glycoproteins. Electric fields cause the lateral migration of plasma membrane concanavalin A receptors toward the cathode in both NIH 3T3 and SV101 fibroblasts. Exposure of directionally migrating cells to Con A inhibits the normal change of cell direction following a reversal of electric field polarity. Additionally, when cells are plated on Con A-coated substrata so that Con A receptors mediate cell-substratum adhesion, cathode-directed locomotion and a cathodal accumulation of Con A receptors are observed. Immunofluorescent labeling of the fibronectin receptor in NIH 3T3 fibroblasts suggests the recruitment of integrins from large clusters to form a more diffuse distribution toward the cathode in field-treated cells. Our results indicate that the mechanism of electric field directed locomotion in NIH 3T3 and SV101 fibroblasts involves the lateral redistribution of plasma membrane glycoproteins involved in cell-substratum adhesion.

Animals↗

Mode of operation of ampullae of Lorenzini of the skate, Raja.

Ampullae of Lorenzini are sensitive electroreceptors. Applied potentials affect receptor cells which transmit synaptically to afferent fibers. Cathodal stimuli in the ampullary lumen sometimes evoke all-or-none "receptor spikes," which are negative-going recorded in the lumen, but more frequently they evoke graded damped oscillations. Cathodal stimuli evoke nerve discharge, usually at stimulus strengths subthreshold for obvious receptor oscillations or spikes. Anodal stimuli decrease any ongoing spontaneous nerve activity. Cathodal stimuli evoke long-lasting depolarizations (generator or postsynaptic potentials) in afferent fibers. Superimposed antidromic spikes are reduced in amplitude, suggesting that the postsynaptic potentials are generated similarly to other excitatory postsynaptic potentials. Anodal stimuli evoke hyperpolarizations of nerves in preparations with tonic activity and in occasional silent preparations; presumably tonic release of excitatory transmitter is decreased. These data are explicable as follows: lumenal faces of receptor cells are tonically (but asynchronously) active generating depolarizing responses. Cathodal stimuli increase this activity, thereby leading to increased depolarization of and increased release of transmitter from serosal faces, which are inexcitable. Anodal stimuli act oppositely. Receptor spikes result from synchronized receptor cell activity. Since cathodal stimuli act directly to hyperpolarize serosal faces, strong cathodal stimuli overcome depolarizing effects of lumenal face activity and are inhibitory. Conversely, strong anodal stimuli depolarize serosal faces, thereby causing release of transmitter, and are excitatory. These properties explain several anomalous features of responses of ampullae of Lorenzini.

Action Potentials↗

Mechanisms of the bactericidal activity of low amperage electric current (DC).

The mechanisms whereby low amperage (10-100 microA) electric current (DC) is bactericidal were investigated with Staphylococcus epidermidis and Staphylococcus aureus. A zone of inhibition test involving the insertion of an anode and cathode into an agar plate inoculated with a lawn of bacteria was used to study the antimicrobial activity of electric current. A zone of inhibition was produced around the cathode when 10 microA (DC) was applied for 16 h. The diameter of the zone was greatly reduced in the presence of catalase. There was no zone around the cathode when the test was carried out under anaerobic conditions. H2O2 was produced at the cathode surface under aerobic conditions but not in the absence of oxygen. A salt-bridge apparatus was used to confirm that H2O2 was produced at the cathode and chlorine at the anode. The antimicrobial activity of low amperage electric current under anaerobic conditions and in the absence of chloride ions against bacteria attached to the surface of a current carrying electrode was also investigated. Antibacterial activity was reduced under anaerobic conditions, which is compatible with the role of H2O2 as a primary bactericidal agent of electricity associated with the cathode. A reduction in chloride ions did not significantly reduce the antibacterial activity suggesting that chlorine plays only a minor role in the bactericidal activity towards organisms attached to anodal electrode surfaces. The localized production of H2O2 and chlorine and the intrinsic activity due to electric current may offer a useful method for eradicating bacteria from catheter surfaces.

Catalase↗

Perceived locus and intensity of electrocutaneous stimulation.

Two experiments investigated perceived locus and intensity for electrocutaneous stimulation. In Experiment 1, 21 subjects reported the perceived locus for various combinations of four electrode sites, two current directions, two pulse characteristics (single versus multiple), and two sensation levels (detection versus pain). In Experiment 2, 16 subjects reported the perceived locus and intensity for a wide range of current levels and two polarity conditions. The main results were 1) sensations were likely to be perceived under the cathode at detection levels, but under both electrodes at intense levels; 2) the "cathode" localization was gradually supplanted by "both" ("anode" and "cathode") localization with increasing current; 3) subjective intensity under the cathode was greater than that under the anode; 4) the effects of cathode position on perceived locus were found for only some pairs of electrodes. These results challenge the simple hypothesis that electrical stimulation of the skin through paired electrodes is perceived under the cathode.

Adult↗

A gastroesophageal electrode for atrial and ventricular pacing.

Temporary transvenous cardiac pacing requires technical expertise and access to fluoroscopy. We have developed a gastroesophageal electrode capable of atrial and ventricular pacing. The flexible polythene gastroesophageal electrode is passed into the stomach under light sedation. Five ring electrodes, now positioned in the lower esophagus, are used for atrial pacing. A point source (cathode) on the distal tip of the electrode, now positioned in the gastric fundus, is used for ventricular pacing. Two configurations of atrial and ventricular pacing were compared: unipolar and bipolar. During unipolar ventricular pacing the indifferent electrode (anode) was a high impedance chest pad. For bipolar ventricular pacing the indifferent electrode was a ring electrodes placed 2 cm proximal to the tip. Unipolar atrial pacing was performed with 1 of 5 proximal ring electrodes acting as cathode ("cathodic") or as anode ("anodic") in conjunction with a chest pad. Bipolar atrial pacing was performed using combinations of 2 of 5 ring electrodes. Atrial capture was obtained in all 55 subjects attempted. When all electrode combinations were compared, atrial capture was significantly more frequent using the bipolar approach (153/210 bipolar, 65/210 unipolar; t = 7.37, P < 0.001). For unipolar atrial pacing, cathodic stimulation (from esophagus) was more successful than anodic stimulation (cathodic 62/105, anodic 20/105; t = 5.81, P < 0.001). In 43 subjects attempted unipolar ventricular pacing resulted in a higher frequency of capture than the bipolar approach (unipolar 41/43 (95.3%), bipolar 19/43 (44.2%); P < 0.001). In conclusion, atrial pacing was optimal using pairs of ring electrodes ("bipolar") while ventricular pacing was optimal using the distal electrode tip (cathode) in conjunction with a chest pad electrode ("unipolar"). This gastroesophageal electrode may be useful in the emergency management of acute bradyarrhythmias and for elective electrophysiological studies.

Adult↗

Delayed activation and retrograde propagation in cardiac muscle: implication of virtual electrode effects.

Point cathodal stimulation of cardiac tissue was shown previously to produce both a dog-bone shaped virtual cathode transverse to the muscle fibers and two longitudinal virtual anodes. We hypothesize that virtual anodes can cause a region of delayed activation, separating two regions of early activation caused by the virtual cathode. Using a high-density electrode array in 42 superfused epicardial slices from 14 canine left ventricles, we observed regions of early and delayed activation and different pathways of retrograde propagation corresponding to the earlier patterns. Retrograde propagation was seen from the transversely located early activation area through areas of delayed activation toward the cathode, and from the early activation area toward the cathode directly. These pathways caused a wide dispersion in the direction of retrograde propagation (2 degrees +/- 31 degrees, n = 179, relative to the fast axis of threshold activation; radial velocity: 0.5 +/- 0.2 m/s, n = 95, in 12 slices from 8 hearts with stimuli of 330 micros, 0.8-30 mA). Delayed activations were observed 0 degrees +/- 6 degrees (n = 32) from the axis in 23 maps (at differing stimulation strengths) recorded in 13 slices from 10 hearts. We conclude that point cathodal stimulation induce delayed activation along the fiber axis and retrograde propagation both along and transverse to the axis.

Animals↗

The effects of electroacupuncture on peripheral nerve regeneration in rats.

This study was designed to examine the effects of electroacupuncture with direct current (DC) on peripheral nerve regeneration. The left sciatic nerve of 55 7-month-old rats was crushed at the thigh. They were ramdomly allocated to four groups: distal cathode DC group (n = 15), distal anode DC group (n = 14), sham operated group (n = 13), and control group (n = 13). In the distal cathode DC group, a cathode electrode was connected to an insulated acupuncture needle inserted at 1 cm distal to the injured site, while an anode electrode was connected to a needle inserted at 1 cm proximal to the lesion. In the distal anode DC group, the anode and the cathode electrode were connected to the needle at 1 cm distal and proximal to the lesion respectively. In the sham operated group, no electrical stimulation was given to the insulated needle inserted at the same site, and in the control group, no treatment was given. Regeneration of the sciatic nerve was evaluated by the number of evoked EMGs recorded at 12 sites in the plantar region, by their latency, and by the weight ratio of the tibialis anterior at four weeks after the crush injury. Regeneration of the peripheral nerve was faster and more accelerated in the distal cathode DC group than in the other groups, while in the distal anode DC group the regeneration was delayed. This result suggested electroacupuncture with cathode distal orientation might be a useful treatment having the advantage of enabling deeper insertion with minimal tissue damage.

Analysis of Variance↗

The cellular electrophysiologic changes induced by high-energy electrical ablation in canine myocardium.

High-energy electrical ablation is a new experimental approach to control arrhythmias. In this study, the cellular electrophysiologic effects of high-energy shocks (5 to 40 J) delivered in vitro to 14 epicardial tissues from 11 dogs were studied in an attempt to understand the nature and extent of injury as well as potential arrhythmogenic mechanisms. In addition, this preparation was used to test the importance of cathode-anode configuration, current density, and fiber orientation in the induction of tissue injury in vitro. Electrophysiologic abnormalities were noted up to 10 mm from the electrode wall, and their extent was determined in part by current density and the cathode-anode orientation. A decrease in resting membrane potential, action potential amplitude, and dV/dT occurred in all tissues after high-energy shocks, which was worst nearest the cathode and of graded severity at increasing distances from the cathode. The most severe effects were noted with high current densities and in tissues located between the cathode and anode. In addition, impaired impulse conduction and abnormal repolarization were documented. Histologic study demonstrated contraction band necrosis immediately after delivery of high-energy shocks. The extent and distribution of the contraction bands was in part dependent on the energy delivered and the cathode-anode configuration. These findings suggest potential mechanisms for arrhythmogenesis and altered regional hemodynamic abnormalities that occur in vivo.

Action Potentials↗

Thresholds for activation of rabbit retinal ganglion cells with an ultrafine, extracellular microelectrode.

PURPOSE: To determine electrical thresholds required for extracellular activation of retinal ganglion cells as part of a project to develop an epiretinal prosthesis. METHODS: Retinal ganglion cells were recorded extracellularly in retinas isolated from adult New Zealand White rabbits. Electrical current pulses of 100- micro s duration were delivered to the inner surface of the retina from a 5- micro m long electrode. In about half of the cells, the point of lowest threshold was found by searching with anodal current pulses; in the other cells, cathodal current pulses were used. RESULTS: Threshold measurements were obtained near the cell bodies of 20 ganglion cells and near the axons of 19 ganglion cells. Both cathodal and anodal stimuli evoked a neural response in the ganglion cells that consisted of a single action potential of near-constant latency that persisted when retinal synaptic transmission was blocked with cadmium chloride. For cell bodies, but not axons, thresholds for both cathodal and anodal stimulation were dependent on the search method used to find the point of lowest threshold. With search and stimulation of matching polarity, cathodal stimuli evoked a ganglion cell response at lower currents (approximately one seventh to one tenth axonal threshold) than did anodal stimuli for both cell bodies and axons. With cathodal search and stimulation, cell body median thresholds were somewhat lower (approximately one half) than the axonal median thresholds. With anodal search and stimulation, cell body median thresholds were approximately the same as axonal median thresholds. CONCLUSIONS: The results suggest that cathodal stimulation should produce lower thresholds, more localized stimulation, and somewhat better selectivity for cell bodies over axons than would anodal stimulation.

Action Potentials↗

Excitability changes induced in the human primary visual cortex by transcranial direct current stimulation: direct electrophysiological evidence.

PURPOSE: Transcranial direct current stimulation (tDCS) has been shown to modify the perception threshold of phosphenes elicited by transcranial magnetic stimulation (TMS). The current study was undertaken to examine whether tDCS, when applied over the occipital cortex, is also able to affect visual-evoked potentials (VEPs), which characterize occipital activation in response to visual stimulation, in a polarity-specific way. METHOD: For this purpose, VEPs evoked by sinusoidal luminance grating in an on/off mode were recorded before, immediately after, and 10, 20, and 30 minutes after the end of 5, 10, or 15 minutes of anodal or cathodal tDCS of the primary visual cortex. RESULTS: Significant effects were observed only when low-contrast visual stimuli were applied. Cathodal stimulation decreased, whereas anodal stimulation increased the amplitude of the N70 component. The effect of cathodal stimulation was significant immediately after and 10 minutes after the end of stimulation, if the stimulation duration was sufficiently long (i.e., 10-15 minutes). An increase of N70 amplitude by anodal stimulation was significant only 10 minutes after the end of the 15 minutes tDCS. Cathodal stimulation tended also to affect the amplitude of the P100 component; however, the effect of stimulation was inverse. The amplitude increased immediately after the end of cathodal stimulation. In contrast, anodal stimulation did not affect the P100. The latencies of the N70 and the P100 were not affected by tDCS. CONCLUSIONS: tDCS appears to be a suitable method of inducing reversible excitability changes in a polarity-specific way, not only in the motor but also in the primary visual cortex. The duration of the induced aftereffects depends not only on stimulation duration but also on stimulation polarity. Cathodal stimulation seems to be more effective, in line with previous reports on the motor cortex.

Adult↗

[The mechanism of impulse initiation: high-resolution epicardial pace-mapping in rat heart].

UNLABELLED: Simulations of cardiac tissue bidomain model indicate that point cathodal stimulation gives rise to a dog-bone depolarized region (virtual cathode) extending across fibers, limited by two symmetric hyperpolarized regions (virtual anode) extending along fibers. These predictions were experimentally confirmed by optical mapping studies of transmembrane potentials while no direct validation is reported at the extracellular level. The present study aims at defining the influence of the virtual cathode on extracellular potentials by means of high-density epicardial mapping. METHODS: Epicardial potentials were measured in seven exposed rat hearts by means of a 11 x 11 electrode array with 360 x 540 microns resolution. Cathodal current pulses, 100-200 microA intensity and 1 ms duration, to avoid superposition of stimulus and activation potentials, were delivered from one of the electrode array and unipolar potentials were measured from all other electrodes. RESULTS AND DISCUSSION: a) During stimulus, negative equipotential lines were elliptic along fibers, as expected, but for a 2 mm circular region at the pacing site. b) During 1-2 ms interval between stimulus offset and start of activation, equipotential lines became elliptic across fibers in the presence of the region directly excited by the stimulus field. Start of activation was either symmetric with isochrones initially circular around the pacing site and then elliptic along fibers, or asymmetric initiating at only one side of the pacing site across fibers with isochrones elliptic along fibers. In the latter case, the wave front was blocked through the refractory region directly excited by the stimulus field, subdivided into two wings which collided and merged at the opposite side, giving rise to a plane wave front propagating across fibers away from the pacing site. CONCLUSIONS: High spatial resolution epicardial potential mapping reveals the existence of the virtual cathode and its influence on impulse initiation and conduction. The unexpected existence of a region of conduction block at the pacing site, due to spatial asymmetry of normal cardiac tissue which enhances activation threshold at one of the two sides of the virtual cathode, is intriguing since it is one of the requirements for reentry of conduction in the presence of a circuit with decreased conduction velocity and short duration of refractory period.

Animals↗

Patterning hydroxyapatite biocoating by electrophoretic deposition.

Patterned bioceramic coatings may find potential applications in orthopedic implants and biosensors. In this study, various hydroxyapatite (HA) patterns were created on silicon and titanium substrates. Electrophoretic deposition technique was used together with surface patterning of the cathode specimen. When gold/palladium patterns (hexagons, spherical dots, etc.) were created on the cathode surface, HA colloidal particles in ethanol would preferentially deposit on the gold-coated area and form patterns. When silicon, instead of gold, was evaporated onto a conducting cathode surface, HA mainly deposited on the exposed area of the substrate. Detailed mechanisms for forming HA patterns may involve local concentration of the electric field when a second metal is patterned on the cathode. The difference in electric field across the two metals on the cathode also enhances HA patterning through an electrohydrodynamic process. This study demonstrated the possibility and flexibility of electrophoretic deposition in patterning charged particles onto a substrate.

Chemistry, Physical↗

Treatment of the damaged rat hippocampus with a locally applied electric field.

Previous studies have indicated that axons may be directed to regenerate toward the cathodal source of a locally applied D.C. electric field. In the present studies, similar galvanotropic effects were tested after partial denervation of the rat hippocampus. Following unilateral fimbrial lesions, 1.5 microA of direct current was applied locally to the tissue for 4 weeks. In the experimental group, the distal (temporal) portion of the hippocampus was located near the cathodal electrode, while the proximal (nasal) portion was located near the anode. In two control groups, either the current was reversed, or there was not current delivered to the tissue. Spontaneous alternation behavior 4 weeks post-operatively in the "cathode distal" rats provided results comparable to those in unoperated (normal) animals, whereas the control animals exhibited statistically significantly greater deficits in memory. The ability to learn the location of a submerged platform in a water tank was evident in unoperated and "cathode distal" animals, but not in either of the control groups. Hippocampal acetylcholinesterase activity in "cathode distal" animals was lower than in unoperated animals, but statistically significantly greater than in the other control animals. Results are consistent with the contention that locally applied weak direct current can modulate long term sequellae of hippocampal injury.

Acetylcholinesterase↗

Proton exchange membrane and electrode surface areas as factors that affect power generation in microbial fuel cells.

Power generation in microbial fuel cells (MFCs) is a function of the surface areas of the proton exchange membrane (PEM) and the cathode relative to that of the anode. To demonstrate this, the sizes of the anode and cathode were varied in two-chambered MFCs having PEMs with three different surface areas (A (PEM)=3.5, 6.2, or 30.6 cm(2)). For a fixed anode and cathode surface area (A (An)=A (Cat)=22.5 cm(2)), the power density normalized to the anode surface area increased with the PEM size in the order 45 mW/m(2) (A (PEM)=3.5 cm(2)), 68 mW/m(2) (A (PEM)=6.2 cm(2)), and 190 mW/m(2) (A (PEM)=30.6 cm(2)). PEM surface area was shown to limit power output when the surface area of the PEM was smaller than that of the electrodes due to an increase in internal resistance. When the relative cross sections of the PEM, anode, and cathode were scaled according to 2A (Cat)=A(PEM)=2A (An), the maximum power densities of the three different MFCs, based on the surface area of the PEM (A (PEM)=3.5, 6.2, or 30.6 cm(2)), were the same (168+/-4.53 mW/m(2)). Increasing the ionic strength and using ferricyanide at the cathode also increased power output.

Bacteria, Anaerobic↗

The effect of direct current field polarity on recovery after acute experimental spinal cord injury.

Recent evidence indicates that direct current (DC) fields promote recovery of acutely injured central and peripheral nervous system axons. The polarity of the applied DC field may play an important role in modulating these effects. In the present study, the effect of DC field polarity on recovery of injured spinal cord axons was examined anatomically, electrophysiologically and behaviourly in a rat model. After a 53 g clip compression injury of the cord at T1, 30 adult rats were randomly and blindly allocated to one of three groups (n = 10 each): one group received implantation of a DC stimulator (14 microA) with the cathode caudal to the injury site; the second group received implantation of a similar stimulator with the cathode rostral to the injury site; and the third group received a sham (O microA) stimulator. Clinical neurological function was assessed by the inclined plane technique and axonal function was assessed by motor- and somatosensory-evoked potentials (MEP and SSEP). A quantitative assessment of axonal integrity was performed by counting neurons in the brain retrogradely labelled by the axonal tracer horseradish peroxidase (HRP) and by counting axons at the injury site. The inclined plane scores (P less than 0.0001), MEP amplitude (P less than 0.02), counts of neurons retrogradely labelled by HRP (P less than 0.0001), and axon counts at the injury site (P less than 0.01) were significantly greater in the group treated with a DC field with the cathode caudal to the lesion than in the other two groups. Conversely, the cathode rostral DC field caused a decrease in the number of neurons retrogradely labelled by HRP (P less than 0.05) compared to the sham and cathode caudal groups. These data confirm our previous finding that DC fields promote recovery of acutely injured spinal cord axons. Furthermore, the polarity of the applied field is of critical importance to this effect.

Animals↗