Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Angiography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42Linked to original sources

Cerebral arteriovenous malformations: comparison of novel magnetic resonance angiographic techniques and conventional catheter angiography.

OBJECTIVE: To investigate the potential of novel magnetic resonance (MR) angiographic techniques for the assessment of cerebral arteriovenous malformations. METHODS: Forty patients who were about to undergo stereotactic radiosurgery were prospectively recruited. Three-dimensional, sliding-slab interleaved ky (SLINKY), time-of-flight acquisition was performed, as was a dynamic MR digital subtraction angiography (DSA) procedure in which single thick slices (6-10 cm) were obtained using a radiofrequency spoiled Fourier-acquired steady-state sequence (1 image/s). Sixty images were acquired, in two or three projections, during passage of a 6- to 10-ml bolus of gadolinium chelate. Subtraction and postprocessing were performed, and images were viewed in an inverted cine mode. SLINKY time-of-flight acquisition was repeated after the administration of gadolinium. Routine stereotactic conventional catheter angiography was performed after MR imaging. All images were assessed (in a blinded randomized manner) for Spetzler-Martin grading and determination of associated vascular pathological features. RESULTS: Forty-one arteriovenous malformations were assessed in 40 patients. Contrast-enhanced (CE) SLINKY MR angiography was the most consistent MR imaging technique, yielding a 95% correlation with the Spetzler-Martin classification defined by conventional catheter angiography; MR DSA exhibited 90% agreement, and SLINKY MR angiography exhibited 81% agreement. CE SLINKY MR angiography provided improved nidus delineation, compared with non-CE SLINKY MR angiography. Dynamic information from MR DSA significantly improved the observation of early-draining veins and associated aneurysms. CONCLUSION: CE SLINKY MR angiographic assessment of cerebral arteriovenous malformations offers significant advantages, compared with the use of non-CE SLINKY MR angiography, including improved nidus demonstration. MR DSA shows promise as a noninvasive method for dynamic angiography but is presently restricted by limitations in both temporal and spatial resolution.

Adult↗

Intracranial aneurysms treated with Guglielmi detachable coils: usefulness of 6-month imaging follow-up with contrast-enhanced MR angiography.

BACKGROUND AND PURPOSE: This study was undertaken to assess the utility of contrast-enhanced MR angiography at 6 months after endovascular treatment of intracranial aneurysms with Guglielmi detachable coils. METHODS: Contrast-enhanced MR angiography was performed in 47 patients at 6 and 12 months after endovascular treatment of intracranial aneurysms (48 aneurysms). Digital subtraction angiography (DSA) was used as reference and was performed at 12 months after the treatment in all patients. MR angiographs were analyzed independently by two senior radiologists. DSA and MR angiography findings were assigned into one of three categories: complete obliteration, residual neck, or residual aneurysm. RESULTS: All examinations were assessable. Interobserver agreement was judged as very good for contrast-enhanced MR angiography (kappa=0.96), with one discrepancy between examiners. Comparison between MR angiography at 6 months and DSA at 12 months showed an excellent agreement between techniques (kappa=0.93). Two cases of complete occlusion at DSA were misclassified as a residual neck at 6-month MR angiography. All aneurysm recanalizations at DSA already were detected on MR angiography at 6 months. The size of aneurysm recanalization did not increase between both MR angiographs performed at 6 and 12 months. CONCLUSION: Contrast-enhanced MR angiography after selective embolization of intracranial aneurysm seems to predict properly early aneurysm recanalizations.

Adult↗

Complete pre-operative imaging assessment of abdominal aortic aneurysm with spiral CT angiography.

PURPOSE: A prospective evaluation of spiral CT angiography (SCTA) as the sole pre-operative imaging modality for abdominal aortic aneurysm repair. MATERIALS AND METHODS: Spiral CT angiography was compared with conventional transfemoral angiography in 30 patients and results correlated with surgical findings in 22 patients. The following features were assessed: renal artery number and disease; upper and lower aneurysm extent; aneurysm size; perianeurysmal inflammation; iliac artery disease; radiation dose; and contrast usage. RESULTS: Spiral CT angiography agreed with conventional angiography in all cases of severe stenosis or occlusion of renal arteries and had 90% agreement overall for renal artery disease. Two of nine accessory renal arteries seen at conventional angiography were missed. For showing aneurysm extent SCTA was 100% sensitive, and performed better than conventional angiography. Aneurysm size was better shown with SCTA. In iliac disease SCTA, as performed in this study, was poor for mild-moderate disease, but detected four of six severely stenosed/occluded iliac arteries seen at conventional angiography. Prospective sensitivity for perianeurysmal inflammation was 33%. Radiation dose for SCTA was approximately twice and contrast dose approximately three times that for conventional angiography. CONCLUSION: Spiral CT angiography can provide all the necessary imaging information to plan aneurysm repair in the non-claudicant.

Aged↗

Hepatic angiography in patients undergoing damage control laparotomy.

OBJECTIVE: Patients undergoing damage control (DC) laparotomy require intensive and aggressive resuscitation, and may require additional maneuvers to control parenchymal bleeding. Those patients suffering significant liver injury are at high risk for arterial bleeding deep within the liver, and many require hepatic angiography in addition to hepatic packing. We reviewed our experience with hepatic angiography, and sought to determine its safety in the DC population of penetrating and blunt trauma patients. METHODS: A 3-year (June 1997-May 2000) retrospective review generated 37 DC patients. Patients sustaining hepatic trauma constituted the study group. Patients undergoing angiography in addition to DC laparotomy were compared with the group of patients not undergoing angiography. Data regarding mechanism of injury, patient demographics, extent of hepatic injury, and presence of associated injuries were collected. Physiologic parameters including vital signs at admission, lowest pH and base excess in the operating room, and lactate levels in the intensive care unit, as well as volumes of fluid resuscitation throughout all phases of DC were examined. Complications including death, intra-abdominal processes, acute respiratory distress syndrome and/or multiple organ dysfunction syndrome, and acute renal failure were reviewed. RESULTS: Nineteen patients (51%) had hepatic trauma and underwent perihepatic packing as a part of DC laparotomy. Eleven had sustained penetrating injury and 8 had blunt injury. There was 1 American Association for the Surgery of Trauma grade I, 5 grade II, 3 grade III, and 10 grade IV injuries. Nine patients in the study population underwent angiography, and eight of these were hepatic artery angiograms. One hepatic angiogram was obtained before operation and seven were obtained in the immediate postoperative period. Six underwent embolization of bleeding hepatic vessels, for a therapeutic liver angiography rate of 75%. There was no statistical difference in physiologic parameters or fluid requirements between the patients who underwent angiography and those who did not. There were no mishaps or complications from angiography or while in the angiography suite. CONCLUSION: Hepatic angiography is a safe adjunct to the principles of damage control. It has a high therapeutic ratio, with no significant untoward effect in this small study population.

Adolescent↗

Suspected dural arteriovenous fistula: results with screening MR angiography in seven patients.

Previous studies have shown that spin-echo (SE) magnetic resonance (MR) imaging has been helpful in the assessment of dural arteriovenous fistula (DAVF); however, direct visualization of the fistula site is limited. Thus, conventional plain angiography is required to establish the diagnosis. Because of this limitation, the additional use of MR angiography may improve noninvasive screening for this disorder. Seven patients with DAVFs proved at plain angiography were evaluated with SE MR imaging and with three-dimensional (3D) time-of-flight (TOF) MR angiography. In six of seven cases, 3D TOF MR angiography demonstrated the fistula site. Correlation was good when compared with findings at plain angiography. Occlusion of the dural sinus was found at plain angiography in three of seven patients but was missed at SE imaging in all three. MR angiography also failed to demonstrate sinus occlusion in two of three patients. Arterial feeders could not be seen on SE MR images, but MR angiography improved their depiction. Plain angiography demonstrated abnormal venous drainage into distended cortical veins in three patients, but dilated cortical veins were noted in only two of the patients on both SE MR images and MR angiograms.

Adult↗

Design-Dependent Variations in Coronary Stent Stenosis Measured as Precisely by Angiography as by Histology.

BACKGROUND: Coronary stent restenosis is a growing clinical concern which, because restenosis may vary with stent design, requires a validated, accurate, and sensitive method of evaluation as new stents are developed. Histologic analysis of arterial cross sections, a highly accurate tool in animal models, has limited applicability in humans. Quantitative coronary angiography, while commonly used in the clinical evaluation of coronary interventions, has a controversial role as an adequate measure of restenosis, and few studies have validated quantitative angiography in diseased arteries. We tested the hypothesis that in-stent stenosis could be assessed as accurately by pre-mortem angiography as by post-mortem histology, allowing angiographic discrimination of variable late luminal loss provoked by stents of different designs. METHODS AND RESULTS: Stent stenosis in porcine coronary arteries was assessed by quantitative coronary angiography and histology at 3, 28 and 56 days. Four stainless steel stent designs were studied: a slotted tube configuration with or without a polymer wrap and a corrugated ring configuration with or without a polymer coating. Although acute luminal gain (mean stent:artery ratio 1.07 +/- 0.01) and stent recoil (mean stent diameter at follow-up 2.65 +/- 0.02 mm) were similar for all designs and time points, significant differences in late luminal loss were observed and were detected as accurately by angiography as by histology. At 28 days, the polymer wrapped slotted tube design resulted in a nearly two-fold greater late loss than its bare metal counterpart (1.40 +/- 0.09 mm vs. 0.80 +/- 0.12 mm, p <.001 by angiography; 1.33 +/- 0.10 mm vs. 0.67 +/- 0.06 mm, p <.0001 by histology), while there was no significant difference in 28 day late loss between the polymer coated and bare metal corrugated ring designs (p = NS by angiography or histology). Time point differences were also observed both angiographically and histologically, with marked progression of lumen loss between 3 and 28 days and slower but persistent progression between 28 and 56 days. Overall comparison of individual lumen diameter measurements for all stented arteries independent of design or duration of follow-up demonstrated a precise correlation between angiography and histology (y = 0.96x +0.25, p <.0001, r2 = 0.82). CONCLUSIONS: Coronary stents of varied designs provoke markedly different degrees of late luminal loss, and these differences can be measured as accurately by quantitative angiography as by histologic analysis of arterial cross sections. This may be due to optimization of angiographic measurements by the concentric nature of intimal thickening in stented arteries, and to structural rigidity imparted by the stent, preserving arterial lumen size for histologic analysis. Quantitative angiography, therefore, may represent an adequate endpoint in clinical trials comparing stent designs.

Journal Article↗

Design-Dependent Variations in Coronary Stent Stenosis Measured as Precisely by Angiography as by Histology.

BACKGROUND: Coronary stent restenosis is a growing clinical concern which, because restenosis may vary with stent design, requires a validated, accurate and sensitive method of evaluation as new stents are developed. Histologic analysis of arterial cross sections, a highly accurate tool in animal models, has limited applicability in humans. Quantitative coronary angiography, while commonly used in the clinical evaluation of coronary interventions, has a controversial role as an adequate measure of restenosis, and few studies have validated quantitative angiography in diseased arteries. We tested the hypothesis that in-stent restenosis could be assessed as accurately by pre-mortem angiography as by post-mortem histology, allowing angiographic discrimination of variable late luminal loss provoked by stents of different designs. METHODS AND RESULTS: Stent stenosis in porcine coronary arteries was assessed by quantitative coronary angiography and histology at 3, 28 and 56 days. Four stainless steel stent designs were studied: a slotted tube configuration with or without a polymer wrap and a corrugated ring configuration with or without a polymer coating. Although acute luminal gain (mean stent:artery ratio of 1.07 +/- 0.01) and stent recoil (mean stent diameter at follow-up 2.65 +/- 0.02 mm) were similar for all designs and time points, significant differences in late luminal loss were observed and were detected as accurately by angiography as by histology. At 28 days, the polymer wrapped slotted tube design resulted in a nearly two-fold greater late loss than its bare metal counterpart (1.40 +/- 0.09 mm vs. 0.80 +/- 0.12 mm, p <.001 by angiography; 1.33 +/- 0.10 mm vs. 0.67 +/- 0.06 mm, p <.0001 by histology), while there was no significant difference in 28 day late loss between the polymer coated and bare metal corrugated ring designs (p = NS by angiography or histology). Time point differences were also observed both angiographically and histologically, with marked progression of lumen loss between 3 and 28 days and slower but persistent progression between 28 and 56 days. Overall comparison of individual lumen diameter measurements for all stented arteries independent of design or duration of follow-up demonstrated a precise correlation between angiography and histology (y = 0.96x +0.25, p <.0001, r2 = 0.82). CONCLUSIONS: Coronary stents of varied designs provoke markedly different degrees of late luminal loss, and these differences can be measured as accurately by quantitative angiography as by histologic analysis of arterial cross sections. This may be due to optimization of angiographic measurements by the concentric nature of intimal thickening in stented arteries, and to structural rigidity imparted by the stent, preserving arterial lumen size for histologic analysis. Quantitative angiography, therefore, may represent an adequate endpoint in clinical trials comparing stent designs.

Journal Article↗

Magnetic resonance angiography has a high reliability in the detection of renal artery stenosis.

In this prospective study we examined the value of magnetic resonance angiography (MRA) in the imaging of the proximal renal arteries, with the main aim of detecting renal arterial stenosis, as compared with intraarterial digital subtraction angiography. The study was done among a group of 38 hypertensive patients seen in the outpatient department of the department of medicine of our university hospital. In all patients a magnetic resonance angiography and an intraarterial subtraction angiography of the renal arteries was made, and the outcomes of the investigations were compared. Clinical and biochemical data of the patients also were analyzed in relation to the presence or absence of a stenosis. In one patient, MRA resulted in technical failure because of unsuspected claustrophobia. Of the remaining 37 patients, 14 had renal artery stenosis. Of 12 patients in whom the stenoses were >50% of luminal surface on intraarterial digital subtraction angiography, eight were unilateral and four bilateral. All these stenoses were recognized by magnetic resonance angiography. There was also one false positive result by magnetic resonance. Thus, for the identification of stenoses >50%, magnetic resonance has a sensitivity of 100% and a specificity of 96%. Of the 12 accessory renal arteries seen on digital subtraction angiography, only three were identified by magnetic resonance angiography. We conclude that magnetic resonance angiography has great accuracy in depicting the main renal arteries and detecting clinically significant renal artery stenosis; however, the identification of accessory renal arteries is suboptimal and should be improved.

Adult↗

Clinical value of pelvic and penile magnetic resonance angiography in preoperative evaluation of penile revascularization.

Penile angiography is invasive, costly and requires postinterventional surveillance. The aim of this pilot study was to determine whether three dimensional magnetic resonance (3D-MR)-angiography may replace conventional penile angiography in preoperative planning of penile revascularization. Twelve patients with a mean age of 39 (21-59) y were evaluated. All patients underwent evaluation with intracavernous pharmacotesting, color Doppler sonography (CDS), digital subtraction angiography (DSA) and pelvic MR-angiography with gadolinium diethylene-triaminepentaacetic acid (Gd-Dota) 0.2-0.3 mmol/kg body weight. MR-angiography demonstrated the anatomy of the internal iliac arteries in 9 out of 12 patients. Intrapenile vessels were visible in 7 out of 12 patients. In comparison DSA provided complete visualization of all pelvic and penile vessels. Relevant arterial obstruction was found in 10 out of 12 patients. CDS revealed a mean maximal arterial flow of 27 (22-40) cm/s and showed in accordance to angiography arterial insuffiency in 10 out of 12 cases. Indication for revascularization could have been based on MR-angiography alone in only one patient. Therefore, selective penile angiography remains the 'gold standard' for preoperative planning of revascularization procedures.

Adult↗

[Indocyanine green angiography in posterior uveitis].

BACKGROUND: Indocyanine-green (ICG) angiography gives additional information in posterior inflammatory conditions by enabling to analyse the choroid. It may become a useful work-up procedure in inflammatory diseases predominantly involving the choroid. Our purpose was to analyse ICG findings and correlate them to fluorescein angiographic and clinical findings in posterior uveitis. PATIENTS AND METHODS: In patients with posterior uveitis involving the choroid, ICG angiography is performed routinely in addition to the usual uveitis work-up. We report on the ICG angiography features found in sarcoidoses (6 cases), birdshot chorioretinopathy (4 cases), multiple evanescent white dot syndrome (MEWDS, 2 cases), Vogt-Koyanagi-Harada disease (2 cases) and multifocal choroiditis (2 cases). RESULTS: The hypofluorescent lesions characteristic for choroidal lesions were seen in all 5 analyzed entities. They corresponded either to active inflammatory lesions or to atrophic areas of the choroid. To distinguish between these 2 situations correlation between clinical findings, fluorescein angiography and ICG angiography was necessary. Except for multifocal choroidits where hypofluorescent areas corresponded essentially to atrophic areas, ICG angiography showed inflammatory choroidal lesions not seen clinically or by fluorescein angiography. ICG hyperfluorescence in the late phase of angiography seemed to be a sign for recent or acute inflammatory involvement. CONCLUSION: ICG angiography was helpful to assess choroidal involvement and disease progression in 4 of the posterior inflammatory disorders examined and will probably prove useful in the work-up of most posterior uveitis involving the choroid.

Angiography↗

Carotid arteries: contrast-enhanced US angiography--preliminary clinical experience.

B-mode ultrasonographic (US) angiography enhanced with a microbubble-based US contrast agent (FS069) was evaluated in human subjects with carotid artery disease. Results at contrast material-enhanced US angiography and duplex US were compared with those at conventional angiography. Both US angiography and duplex US accurately depicted stenoses of 70% or more compared with those depicted at conventional angiography. The percentage diameter stenosis of the internal carotid artery measured at US angiography strongly correlated with that measured at conventional angiography (r = 0.988). The percentage area stenosis measured at US angiography strongly correlated with ex vivo measurements of the resected carotid plaque at magnetic resonance imaging (r = 0.979). US angiography depicted unsuspected wall irregularities, ulceration, and dissection.

Aged↗

Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography.

PURPOSE: To demonstrate the utility of low-dose gadolinium-enhanced magnetic resonance (MR) angiography of two consecutive anatomic areas for assessment of peripheral vascular disease. MATERIALS AND METHODS: Fifteen patients underwent gadolinium-enhanced MR angiography for evaluation of lower extremity peripheral vascular disease after conventional digital subtraction angiography (DSA). MR angiography was performed with three-dimensional coronal gradient-echo acquisitions before and during administration of gadopentetate dimeglumine. Two separate, contiguous areas were studied with separate doses of 0.075 and 0.1 mmol/kg gadopentetate dimeglumine. MR angiography findings were compared with DSA findings; DSA was the standard of reference. Treatment options were determined first with MR angiograms and then with DSA images. RESULTS: For distinguishing greater than 50% stenosis from 50% or less stenosis, gadolinium-enhanced MR angiography yielded a sensitivity of 97%, a specificity of 96%, and an accuracy of 97%. In 146 (97%) of 150 anatomic segments, there was essential or total agreement on treatments determined with MR angiography and DSA. In two cases (one case of vascular stent placement and one case of surgical anastomosis), extent of disease was overestimated with MR angiography. The MR study of one infrapopliteal area was insufficient for evaluation. CONCLUSION: Accurate gadolinium-enhanced MR angiography of multiple peripheral vascular areas of the lower extremities can be performed in most patients with less than 0.2 mmol/kg contrast material.

Aged↗

Pulmonary embolism: comparison of cut-film and digital pulmonary angiography.

PURPOSE: To compare "cut-film" (film hard-copy) angiography (CFA) with digital pulmonary angiography in the detection of pulmonary embolism (PE). MATERIALS AND METHODS: Thirty-six adult patients (39 lungs) underwent selective digital pulmonary angiography for suspected PE. Imaging was repeated in one selected projection by using cut film. The standard was consensus interpretation of both CFA and digital angiographic images and clinical course. Three vascular radiologists subsequently reviewed the digital and cut-film images in a blinded fashion and ranked the likelihood of the presence of PE on a five-point scale. The two modalities were compared by means of receiver operating characteristic (ROC) analysis. Image quality (i.e., sharpness, opacification of subsegmental vessels, and exposure) was judged on a three-point scale. The highest-order pulmonary artery branch seen on each study was recorded. RESULTS: ROC curve analyses for all three operators showed similar diagnostic performance for digital pulmonary angiography and CFA, with one operator showing better performance with digital subtraction angiography than with CFA (P = .04). Compared with the final diagnosis, single-plane digital pulmonary angiography had higher sensitivity for the detection of PE than had CFA. The specificity was 100% for both modalities. The mean score in patients with findings positive for PE was higher in the digital pulmonary angiography group than in the CFA group (P < .005). There was no difference in the mean score in patients who did not have a PE. There also was no difference in the smallest detectable subsegmental branch (P = .87) or in the average estimate of image quality. CONCLUSION: Selective digital pulmonary angiography and CFA offer similar diagnostic performance and image quality. Digital pulmonary angiography is a reasonable alternative to CFA in the diagnosis of PE.

Adult↗

Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience.

PURPOSE: To compare stepping-table digital subtraction gadolinium-enhanced magnetic resonance (MR) angiography of the distal aorta and lower extremity arteries with conventional catheter digital subtraction x-ray angiography in patients with arterio-occlusive disease. MATERIALS AND METHODS: Twenty patients underwent both conventional catheter angiography and fast three-dimensional gadolinium-enhanced MR angiography of the aorta and outflow vessels at 1.5 T; the images were acquired in three consecutive imaging locations during a single infusion of a gadolinium chelate. RESULTS: Compared with catheter angiography, according to the findings of two blinded independent reviewers, MR angiography had sensitivities of 81% and 89% and specificities of 91% and 95%, respectively, for demonstration of insignificant (< or = 50%) stenosis versus significant (51%-100%) stenosis. For demonstration of occlusion, the sensitivity and specificity were 94% and 97%, respectively, by consensus. There was good interobserver correlation between the two readers overall (kappa = 0.65 for reporting the degree of narrowing in all lesions; 0.86, for reporting of insignificant versus significant stenoses; and 0.928, for reporting of occluded versus patient segments). CONCLUSION: Stepping-table digital subtraction contrast material-enhanced MR angiography has high accuracy compared with catheter angiography in patients with arterio-occlusive disease of the aorta and outflow vessels. These preliminary study results suggest that this technique may ultimately provide a safe, noninvasive, and cost-effective alternative to catheter angiography.

Aged↗

Renal arterial stenosis: prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography.

PURPOSE: To compare color Doppler ultrasonography (US) with fast, breath-hold, three-dimensional, gadolinium-enhanced magnetic resonance (MR) angiography in detecting renal arterial stenosis. MATERIALS AND METHODS: Forty-five patients with clinical suspicion of renovascular disease were prospectively examined with intra- and extrarenal color Doppler US and breath-hold, gadolinium-enhanced MR angiography. Digital subtraction arteriography (DSA) was the standard of reference in all patients for the number of renal arteries and degree of stenosis. RESULTS: DSA depicted 103 arteries and 52 stenoses. Color Doppler US was nondiagnostic in two examinations. Significantly more of 13 accessory renal arteries were detected with MR angiography (n = 12) than with color Doppler US (n = 3; P <.05). For assessing all stenoses, the sensitivity and accuracy were 94% and 91%, respectively, for MR angiography and 71% and 76%, respectively, for US (P <.05). The sensitivity was higher for MR angiography (100%) than for US (79%; P <.05) in diagnosing stenoses with at least 50% narrowing. The specificity, accuracy, and negative predictive value in diagnosing stenoses of at least 50% narrowing were 93%, 95%, and 100% for MR angiography and 93%, 89%, and 90% for US. CONCLUSION: Breath-hold, gadolinium-enhanced MR angiography is superior to color Doppler US in accessory renal artery detection. Although the specificity of MR angiography is similar to that of color Doppler US, MR angiography has a better sensitivity and negative predictive value in depicting renal arterial stenoses.

Adult↗

Aortic aneurysmal disease: assessment of stent-graft treatment-CT versus conventional angiography.

PURPOSE: To compare computed tomographic (CT) angiography and conventional angiography for determining the success of endoluminal stent-graft treatment of aortic aneurysms. MATERIALS AND METHODS: Forty patients underwent conventional angiography and CT angiography following treatment of aortoiliac aneurysms with endoluminal stent-grafts. Six additional sets of conventional angiographic-CT angiographic examinations were performed in five patients after placement of additional stent-grafts or coil embolization to treat perigraft leakage. Three faculty CT radiologists who were blinded to patient clinical data and outcome independently interpreted the CT angiograms, and three faculty angiographers, who were not involved in the stent-graft deployment, interpreted the conventional angiograms. Images were assessed for the presence of postdeployment complications. A reference standard was developed by experienced radiologists using all available images and clinical data. Sensitivities, specificities, and kappa values were calculated. RESULTS: Perigraft leakage was the most commonly identified complication. Twenty perigraft leaks were detected in the results of 46 examinations. Sensitivities and specificities for detecting perigraft leakage were 63% and 77% for conventional angiography and 92% and 90% for CT angiography, respectively. The kappa value was 0. 41 for conventional angiography and 0.81 for CT angiography. CONCLUSION: CT angiography is the preferred method for establishing the presence of perigraft leakage following treatment of aortoiliac aneurysms with stent-grafts.

Adult↗

Perimesencephalic hemorrhage and CT angiography: A decision analysis.

BACKGROUND AND PURPOSE: The method of choice for detecting or excluding a vertebrobasilar aneurysm still is a matter of debate in patients with a characteristically perimesencephalic pattern of subarachnoid hemorrhage (SAH) on CT. We used decision analysis to compare possible diagnostic strategies in these patients. METHODS: A decision analytic model was developed to evaluate the effect of 4 different diagnostic strategies following a perimesencephalic pattern of SAH on CT: 1, no further investigation; 2, digital subtraction angiography (DSA) by catheter; 3, CT angiography as initial modality, not followed by DSA if negative; and 4, CT angiography as initial modality, followed by DSA. We used a 4% prevalence of a vertebrobasilar aneurysm given a perimesencephalic pattern of hemorrhage, a 97% sensitivity and specificity of CT angiography, and a 99.5% sensitivity and 100% specificity of DSA. In a prospectively collected series, the complication rate from DSA in patients with a perimesencephalic pattern of hemorrhage was 2.6%. We calculated the expected utility of each of the 4 diagnostic options and used sensitivity analyses to examine the influence of the plausible ranges of the various estimates used. RESULTS: The expected utilities were 99.09 for CT angiography only, 98.96 for no further investigation, 98.22 for DSA, and 96.34 for CT angiography plus DSA. The results of the sensitivity analysis indicate that over a wide range of assumptions, CT angiography only is the most beneficial option. Only when the complication rate of catheter angiography is <0.2% is DSA the preferred strategy. CONCLUSIONS: Our decision analysis shows that in patients with a perimesencephalic pattern of hemorrhage on CT, CT angiography only is the best diagnostic strategy. DSA can be omitted in patients with a perimesencephalic pattern of hemorrhage and a negative CT angiogram.

Angiography, Digital Subtraction↗

High-resolution turbo magnetic resonance angiography for diagnosis of Moyamoya disease.

BACKGROUND AND PURPOSE: High-resolution turbo MR angiography with zero-filling interpolation (ZFI) technique is a new vascular imaging method with reduced scan time. The purpose of the present study was to evaluate high-resolution turbo MR angiography for the diagnosis and assessment of moyamoya disease. METHODS: Forty-six patients suspected of having moyamoya disease were examined with high-resolution turbo MR angiography with the ZFI technique, MRI, and conventional angiography. Moyamoya disease was diagnosed in 42 of these patients. Blind, separate interpretation of the images was performed. RESULTS: High-resolution turbo MR angiography and MRI accurately evaluated 349 (95%) and 325 (88%) of 368 arteries, respectively, but the degree of stenosis was overestimated in the other arteries. MR angiography and MRI depicted basal cerebral moyamoya vessels in 82 (98%) and 82 (98%) of 84 hemispheres, respectively. MR angiography also depicted leptomeningeal and transdural collateral vessels in 51 (100%) of 51 hemispheres and in 38 (88%) of 43 hemispheres, respectively. The sensitivity and specificity of high-resolution turbo MR angiography for the diagnosis of moyamoya disease were 98% and 100%, respectively. CONCLUSIONS: High-resolution turbo MR angiography in reduced scan time is highly accurate in the assessment of both steno-occlusive lesions and collateral vessels in moyamoya disease, thus providing a highly accurate (98%) diagnosis and assessment of moyamoya disease.

Adolescent↗