Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Development of a quantitative real-time detection assay for hepatitis B virus DNA and comparison with two commercial assays.

A highly reproducible and sensitive real-time detection assay based on TaqMan technology was developed for the detection of hepatitis B virus (HBV) DNA and compared with two commercially available assays. The assay was validated with the Viral Quality Control panel, which also includes EUROHEP HBV DNA standards. This real-time PCR detection system had a dynamic range of 373 to 10(10) genome copies per ml and showed an excellent correlation with both the commercial HBV Digene Hybrid Capture II microplate assay (Digene Diagnostics) and the HBV MONITOR assay (Roche Diagnostics). To demonstrate its clinical utility, four chronically HBV-infected patients treated with lamuvidine were monitored using the three different assays. From the results we concluded that this assay is an excellent alternative for monitoring of HBV-infected patients in routine diagnostics and clinical practice, enabling the analysis of a large dynamic range of HBV DNA in a single, undiluted sample.

Antiviral Agents↗

Role of beat noise in limiting the sensitivity of optical coherence tomography.

The sensitivity and dynamic range of optical coherence tomography (OCT) are calculated for instruments utilizing two common interferometer configurations and detection schemes. Previous researchers recognized that the performance of dual-balanced OCT instruments is severely limited by beat noise, which is generated by incoherent light backscattered from the sample. However, beat noise has been ignored in previous calculations of Michelson OCT performance. Our measurements of instrument noise confirm the presence of beat noise even in a simple Michelson interferometer configuration with a single photodetector. Including this noise, we calculate the dynamic range as a function of OCT light source power, and find that instruments employing balanced interferometers and balanced detectors can achieve a sensitivity up to six times greater than those based on a simple Michelson interferometer, thereby boosting image acquisition speed by the same factor for equal image quality. However, this advantage of balanced systems is degraded for source powers greater than a few milliwatts. We trace the concept of beat noise back to an earlier paper.

Artifacts↗

Evolutionary optimization of fluorescent proteins for intracellular FRET.

Fluorescent proteins that exhibit Forster resonance energy transfer (FRET) have made a strong impact as they enable measurement of molecular-scale distances through changes in fluorescence. FRET-based approaches have enabled otherwise intractable measurements of molecular concentrations, binding interactions and catalytic activity, but are limited by the dynamic range and sensitivity of the donor-acceptor pair. To address this problem, we applied a quantitative evolutionary strategy using fluorescence-activated cell sorting to optimize a cyan-yellow fluorescent protein pair for FRET. The resulting pair, CyPet-YPet, exhibited a 20-fold ratiometric FRET signal change, as compared to threefold for the parental pair. The optimized FRET pair enabled high-throughput flow cytometric screening of cells undergoing caspase-3-dependent apoptosis. The CyPet-YPet energy transfer pair provides substantially improved sensitivity and dynamic range for a broad range of molecular imaging and screening applications.

Bacterial Proteins↗

Second phase of formalin-induced excitation of spinal dorsal horn neurons in spinalized rats is reversed by sciatic nerve block.

Considerable debate persists concerning peripheral vs. central mechanisms underlying the second phase of the nociceptive response in the formalin test in the rat. To gain insight into the neurophysiological basis of this pain, we investigated the effects of block of afferent nerve conduction during the second phase of formalin-evoked excitation of single nociceptive neurons recorded extracellularly from rat spinal dorsal horn segments (L(3-4)) in pentobarbital-anaesthetized, male Sprague-Dawley rats. Rats were spinally transected (T(9)) to examine exclusively peripheral and spinal nociceptive processing. In six control rats, hind paw intraplantar formalin injection (50 microL, 2.5%) induced the typical biphasic increase in the discharge rate of the six wide dynamic range neurons tested. This response consisted of a relatively brief immediate phase (approximately 5 min), followed by decreased firing. An ensuing second phase of elevated discharge began approximately 35 min after injection and persisted to at least 80 min. In this control group, 0.9% saline was applied to the exposed ipsilateral sciatic nerve after onset of the second phase (40 min after formalin injection). In a group of six test rats, application of 2% lidocaine instead of saline reversed the second phase of excitation in all six wide dynamic range neurons examined. When the firing rate was normalized to that at 40 min (100%), the time of saline or lidocaine administration, the rate at 50 min was 120 +/- 7.5% in the saline-treated group and 31 +/- 7.4% in the lidocaine-treated group; following lidocaine treatment firing rate remained markedly less than that before administration throughout the remainder of the recording. It is concluded that: (i) spinal mechanisms alone are not sufficient for induction and maintenance of second phase increased discharge of spinal nociceptive dorsal horn neurons; (ii) descending influences via supraspinal inputs are not causal in the development and maintenance of second phase increased discharge and (iii) tonic input from afferent neurons during the second phase plays a primary and essential role in generating and sustaining the second phase of elevated discharge of dorsal horn neurons and, thus, presumably the second phase of nociceptive scores in the formalin test. The data in this study reveal how much of an altered synaptically elicited response in the spinal dorsal horn can be attributed to postsynaptic plastic changes vs. how much can be simply due to increased synaptic input. The present results are important not only in the context of the formalin test but also in the context of other models related to inflammatory pain and neuropathic pain.

Action Potentials↗

Intact-protein-based high-resolution three-dimensional quantitative analysis system for proteome profiling of biological fluids.

The substantial complexity and vast dynamic range of protein abundance in biological fluids, notably serum and plasma, present a formidable challenge for comprehensive protein analysis. Integration of multiple technologies is required to achieve high-resolution and high-sensitivity proteomics analysis of biological fluids. We have implemented an orthogonal three-dimensional intact-protein analysis system (IPAS), coupled with protein tagging and immunodepletion of abundant proteins, to quantitatively profile the human plasma proteome. Following immunodepletion, plasma proteins in each of paired samples are concentrated and labeled with a different Cy dye, before mixing. Proteins are subsequently separated in three dimensions according to their charge, hydrophobicity, and molecular mass. Differences in the abundance of resolved proteins are determined based on Cy dye ratios. We have applied this strategy to profile the plasma proteome for changes that occur with acute graft-versus-host disease (GVHD), following allogeneic bone marrow transplantation (BMT). Using capillary HPLC ESI Q-TOF MS, we identified 75 proteins in the micromolar to femtomolar range that exhibited quantitative differences between the pre- and post-GVHD samples. These proteins included serum amyloid A, apolipoproteins A-I/A-IV, and complement C3 that are well-known acute-phase reactants likely reflecting the post-BMT inflammatory state. In addition, we identified some potentially interesting immunologically relevant molecules including vitamin D-binding protein, fetuin, vitronectin, proline-rich protein 3 and 4, integrin-alpha, and leukocyte antigen CD97. IPAS provides a combination of comprehensive profiling and quantitative analysis, with a substantial dynamic range, for disease-related applications.

Adult↗

Characterization of biphasic modulation of spinal nociceptive transmission by neurotensin in the rat rostral ventromedial medulla.

Modulation of spinal nociceptive transmission by neurotensin microinjected in the rostral ventromedial medulla (RVM) was examined in anesthetized, paralyzed rats. Forty-three spinal dorsal horn neurons in the L3-L5 spinal segments responding to mechanical and noxious thermal stimulation (50 degrees C) of the plantar surface of the ipsilateral hind foot were studied. Spinal units were classified as either wide dynamic range or nociceptive specific and were located in spinal laminae I-V. Microinjection of neurotensin (0.03 pmol/0.2 microl) into the RVM produced a significant facilitation (135% of control) of spinal unit responses to noxious thermal stimulation (50 degrees C) that lasted approximately 12 min. In contrast, injection of greater doses of neurotensin (300 or 3,000 pmol) produced an inhibition of spinal unit responses to noxious heat (51.7 and 10.6% of control, respectively) that had a longer duration (60-120 min). The effects of neurotensin on wide-dynamic-range and nociceptive-specific neuron responses to noxious heat were qualitatively and quantitatively similar. Spinal unit responses to graded heating of the skin (42-50 degrees C) were completely inhibited after microinjection of 3,000 pmol of neurotensin into the RVM. Injection of a lesser dose of neurotensin (300 pmol), however, resulted in a partial inhibition of spinal unit responses and significantly reduced the slope of the stimulus-response function to graded heating of the skin. Transection of either the ipsilateral or contralateral dorsolateral funiculus (DLF) significantly reduced the inhibition of spinal nociceptive transmission produced by neurotensin (3,000 pmol) in the RVM, whereas bilateral transection of the DLFs completely blocked the effect. In contrast, bilateral transection of the DLFs had no effect on facilitation of spinal nociception by neurotensin (0.03 pmol) in the RVM. The inhibition of spinal nociceptive transmission by neurotensin (3,000 pmol) in the RVM was completely blocked by injection of the nonpeptide neurotensin receptor antagonist SR48692 (30 fmol) into the RVM 10 min before neurotensin. To confirm a specific block of neurotensin-receptor-mediated effects by the antagonist, a subsequent injection of L-glutamate into the RVM was performed. L-Glutamate (100 nmol) was found to inhibit the nociceptive responses of those spinal units whose responses were no longer inhibited by neurotensin. In contrast, injection of SR48692 (30 fmol) into the RVM failed to block the facilitation of spinal unit responses to noxious heat produced by a subsequent injection of neurotensin (0.03 pmol) into the same site. The present series of experiments demonstrate a specific role for neurotensin in the RVM in the modulation of spinal nociceptive transmission, because the peptide was found to both facilitate and inhibit spinal neuron responses to noxious thermal stimulation. Additionally, the facilitatory and inhibitory effects of neurotensin appear to occur via interaction with multiple neurotensin receptors in the RVM that activate independent systems that descend in the ventrolateral funiculi and DLFs, respectively. The results from these experiments are consistent with prior studies demonstrating that the RVM both facilitates and inhibits spinal nociceptive transmission, and they complement previous work showing that neurotensin in the RVM modulates spinal nociceptive behavioral responses.

Animals↗

Neural representation of cutaneous aftersensations by spinothalamic tract neurons.

Temporal summation of second pain and long-lasting tactile-evoked aftersensations are examples of sensory phenomenons that cannot be explained on the basis of responses of primary afferents. Two distinct classes of monkey spinothalamic tract neurons have responses to controlled natural stimuli that parallel and thus could account for the above phenomenons. One class, termed wide-dynamic-range, receives excitatory effects from sensitive mechanoreceptive afferents and from various nociceptive afferents including Adelta and C mechanothermal nociceptive afferents. Another class, termed nociceptive-specific, receives excitatory effects exclusively from primary nociceptive afferents. Both classes respond with an early and late response to a single noxious heat pulse (peak temperature = 51 C). The late response, unlike C nociceptive afferents but like second pain, summates in magnitude with each successive heat pulse. Gentle moving tactile stimuli evoke long-lasting (20-56 sec) after-discharges only in wide dynamic range neurons, and are similar in duration to the tactile after-sensation evoked by similar stimuli. Both the after-discharges and after-sensations can be abruptly terminated by rubbing the affected region. Temporal summation of second pain and cutaneous after-sensations are at least partly subserved by spinal cord mechanisms within the dorsal horn and are manifested in the output of spinothalamic tract neurons.

Animals↗

An image visualization tool in mammography.

The poor detectability of diagnostic mammographic features, due to their low contrast, is dealt with by a software visualization tool. The tool is domain specific to medical imaging and consequently mammographic imaging, and it is envisaged as part of medical image visualization and manipulation stations. Domain specificity is served by the tool conformance to DICOM 3.0 part 10 image format specifications, specifically PAPYRUS 3.0, window width/level display adjustments of image dynamic range of up to 16 bits, and application of visualization operations to user-defined regions of interest in addition to global operations. The software has been designed and implemented according to an object oriented approach in Visual C++. The tool user interface is friendly, based on a widely used windowing paradigm, the Microsoft Foundation Class library version 4.2, which provides interface items, such as windows, dialogue boxes, lists, slide bars, buttons, etc. The visualization functionality offered by the tool relies on the following three categories of image processing algorithms: dynamic range adjustments by pixel intensity transformations, contrast enhancement and noise suppression by spatial domain direct manipulation of image pixels or by manipulation of wavelet coefficients. The first two categories of algorithms are implemented in real time. Initial use of the tool has demonstrated its potential in improving the detectability of diagnostic mammographic image features.

Algorithms↗

The performance of a CCD digital autoradiography imaging system.

Autoradiography is a widely used technique for imaging trace quantities of radioactivity within biological samples, conventionally using photographic film. This method produces images with high spatial resolution, but it suffers from very low sensitivity and poor dynamic range. Digital autoradiography systems with greatly improved sensitivity and linearity are commercially available, but the spatial resolution is usually much less than that achieved using film. We report here the design, construction and characterization of a novel digital autoradiography system based on scientific-grade charged coupled devices (CCDs). Images of x-ray and beta emissions from radionuclides commonly used in autoradiography show that the system can perform high-speed quantitative imaging with a spatial resolution of approximately 30, microm. Using a frame by frame acquisition method the dynamic range is shown to be at least three orders of magnitude. The absolute detection efficiency is comparable to the best of the currently available digital systems. CCD images of 125I and 14C radioisotope distributions in tissue samples are superior to the equivalent film images and have been acquired in 1-10% of the time.

Animals↗

Influence of data acquisition environment on accuracy of acoustic voice quality measurements.

Accuracy of acoustic voice analysis is influenced by the quality of recording. Lately, articles have suggested that soundcards perform equivalently to specialized professional-grade data acquisition (DA) systems. The purpose of this study was to investigate the influence of DA environment (DA system and microphone) on acoustic voice quality measurement (VQM) while balancing for gender, age, intersubject and intrasubject variability, and analysis software. More specifically, the relative performance of different hardware environments and the relationship between their technical characteristics and VQM performance was investigated. The discretization error and the effective dynamic range of the different DA environments were measured. We used 3 software systems to record and measure separately 2000 acoustic samples of sustained phonation for fundamental frequency, jitter, and shimmer. Analyses of variance (ANOVA) were performed with these parameters as the dependent variables. The results of the study suggested that professional-grade DA hardware is strongly recommended to provide accurate and valid voice assessment. The fundamental frequency measurement differences across DA environments were highly correlated to the discretization error (r=1.00), whereas jitter and shimmer were highly correlated to the effective dynamic range of the DA environments (r=-0.68 and r=-0.86, respectively).

Adult↗

Phenylene ring dynamics in bisphenol-A-polysulfone by neutron scattering.

We have investigated the dynamics of phenylene rings in a glassy polysulfone (bisphenol-A-polysulfone) by means of quasielastic neutron scattering. Nowadays it is well known that these molecular motions are directly connected with the mechanical properties of engineering thermoplastics in general. The particular system investigated by us has the advantage that by selective deuteration of the methyl groups, the neutron scattering measured is dominated by the incoherent contribution from the protons in the phenylene rings. In this way, the dynamics of such molecular groups can be experimentally isolated. Two different types of neutron spectrometers: time of flight and backscattering, were used in order to cover a wide dynamic range, which extends from microscopic (10(-13) s) to mesoscopic (10(-9) s) times. Moreover, neutron diffraction experiments with polarization analysis were also carried out in order to characterize the structural features of the sample investigated. Fast oscillations of increasing amplitude with temperature and pi-flips are identified for phenylene rings motions. Due to the structural disorder characteristic of the amorphous state, both molecular motions display a broad distribution of relaxation times, which spreads over several orders of magnitude. Based on the results obtained, we propose a model for phenylene rings dynamics, which combines the two kinds of molecular motions identified. This model nicely describes the neutron scattering results in the whole dynamic range investigated.

Journal Article↗

Clinical evaluation of the Clarion CII HiFocus 1 with and without positioner.

OBJECTIVE: To study the clinical outcomes concerning speech perception of the Clarion CII HiFocus 1 with and without a positioner and link those outcomes with the functional implications of perimodiolar electrode designs, focusing on intrascalar position, insertion depth, stimulation levels, and intracochlear conductivity pathways. DESIGN: The speech perception scores of 25 consecutive patients with the Clarion CII HiFocus 1 implanted with a positioner and 20 patients without a positioner were prospectively determined. Improved multislice CT imaging was used to study the position of the individual electrode contacts relative to the modiolus and their insertion depth. Furthermore, stimulation thresholds, maximum comfort levels, and dynamic ranges were obtained. Finally, these data were associated with intracochlear conductivity paths as calculated from the potential distribution acquired with electrical field imaging. RESULTS: Implantation with a Clarion Hifocus 1 with positioner showed significantly higher speech perception levels at 3 mos, 6 mos, and 1 yr (p < 0.05) after implantation. Basally, the positioner brought the electrode contacts significantly closer to the modiolus, whereas apically no difference in distance toward the modiolus was present. Moreover, the patients with the electrode array in a perimodiolar position showed deeper insertions. The T-levels and dynamic range were not significantly different between the positioner and nonpositioner patients. Furthermore, the intracochlear conductivity paths showed no significant differences. However, a basal current drain is present for the shallowly inserted nonpositioner patients. CONCLUSIONS: A basally perimodiolar electrode design benefits speech perception. The combination of decreased distance to the modiolus, improved insertion depth, and insulating properties of the electrode array have functional implications for the clinical outcomes of the perimodiolar electrode design. Further research is needed to elucidate their individual contributions to those outcomes.

Adolescent↗

Development and validation of a rotor-gene real-time PCR assay for detection, identification, and quantification of Chlamydia trachomatis in a single reaction.

A multitarget real-time PCR (MRT-PCR) for detection of Chlamydia trachomatis DNA was developed and validated. There were three targets for amplification in a single reaction: the cryptic plasmid (CP), the major outer membrane protein (MOMP) gene, and an internal control. The assay had the following characteristics: (i) detection and confirmation of the presence of C. trachomatis DNA in a single reaction, (ii) detection of all genovars of C. trachomatis without any cross-reactivity with pathogenic bacteria or commensal organisms of the oropharynx and genital tract, (iii) a 95% probability of detection with three copies of MOMP and one copy of CP per reaction mixture, (iv) identification of the inhibition of amplification, (v) a quantitative dynamic range of 25 to 250,000 genome copies per reaction mixture, (vi) high intra- and interassay reproducibilities, and (vii) correct identification of all samples in the validation panel. There were 146 COBAS Amplicor PCR (Amplicor PCR)-positive samples and 122 Amplicor PCR-negative samples in the panel. MRT-PCR detected CP DNA alone in 6 (4%) Amplicor PCR-positive samples and both CP and MOMP DNAs in 140 (96%) of 146 Amplicor PCR-positive samples. The quantity of MOMP DNA in 95 (68%) of 140 samples was within the dynamic range of the assay. The median C. trachomatis load in these samples was 321 genome copies per reaction mixture (range, 26 to 40,137 genome copies per reaction mixture). Due to the inclusion of two different C. trachomatis-specific targets, the assay confirmed 259 (97%) of 268 results in a single reaction. This assay could be used in the qualitative format for the routine detection of C. trachomatis and in the quantitative format for study of the pathogenesis of C. trachomatis-associated diseases. The assay demonstrated the potential to eliminate the need for confirmatory testing in almost all samples, thus reducing the turnaround time and the workload.

Bacterial Outer Membrane Proteins↗

Influence of stimulus level on acoustic motion-direction sensitivity in barn owl midbrain neurons.

1. Many neurons in the owl's midbrain are able to discriminate by their responses the motion of an acoustic source in one direction, the preferred direction, from the motion of the source in the opposite direction, the null direction. This differential response can be understood by the action of an acoustic motion detector. However, the motion detector would work in an effective way only if the motion direction-sensitive responses of a cell were largely independent of stimulus level. 2. We investigated the level dependence of acoustic motion sensitivity in midbrain neurons with standard extracellular recording techniques. We used an apparent motion paradigm with sounds moving clockwise or counterclockwise in the horizontal plane or stationary sounds for stimulation from free-field speakers. In most cases we added a constant level of background noise to the stimuli having a variable level. Thus we could analyze the responses as a function of the signal-to-noise ratio. 3. Moving and stationary sounds yielded similar response thresholds and similar dynamic ranges. 4. When the background level was changed the response threshold changed accordingly, so that the response threshold always occurred at a constant signal-to-noise ratio independent of background level. 5. The preferred direction of all cells was independent of stimulus level and some 22 percent of the cells showed a directional bias of their response at threshold. In no cell was a change in the preferred direction observed when stimulus level was varied. Typically, however, the motion direction sensitivity, measured by a signed directionality index, was not maximal at threshold. However, the dynamic range, i.e., the range of stimulus levels over which motion direction sensitivity changed, was < or = 20 dB in most cases. Therefore these cells are indeed able to encode motion direction largely independently of stimulus level. 6. We discuss the data within the framework of the acoustic motion detector mentioned above and with respect to earlier reports on acoustic motion sensitivity in the owl and other animals.

Animals↗

Development of a high-throughput robotic fluorescence-based assay for HsEg5 inhibitor screening.

HsEg5 has microtubule-activated ATPase activity and plays essential roles in bipolar spindle formation. Because HsEg5 is validated as an attractive cancer target, in vitro biochemical assays have been developed for identifying compounds with high inhibitory activity. Several compounds, including quinazoline ring-containing compounds, have been identified and are currently in clinical trials. Although considerable progress has been made during recent years, limitations of HsEg5 in vitro screening assays still reside in two main aspects. First, colorimetric-based assays exhibit relatively low sensitivity and limited dynamic range that are unable to accurately measure compounds with nanomolar potencies. Second, current fluorescence assays are relatively low throughput without "mix and read" homogeneous features. In this study, we describe a sensitive fluorescence-based assay for HsEg5-specific inhibitors. By coupling several enzymes' activities, the release of ADP was measured quantitatively through red fluorescent resorufin. The Km for ATP hydrolysis in this assay was calculated as 23 microM. The known HsEg5 inhibitors CK0106023 and CK0238273 gave IC50 values of 9.8 and 30.6 nM, respectively. Our fluorescence assay has a 20-fold increase in sensitivity with broader dynamic range when compared with a colorimetric assay. We further automated this assay for high-throughput screening with a Z' factor of 0.8.

Adenosine Diphosphate↗

[Category loudness scaling to evaluate sound perception in cochlear and retro-cochlear lesions].

Category loudness scaling was used to investigate the loudness perception of 31 patients with a cochlear hearing loss (Group 1) by comparing the results with those found in 15 patients with retro-cochlear hearing loss caused by an acoustic neuroma (Group 2). Narrow-band noise signals at four different frequencies (0.5 to 4.0 kHz) were used. In the cochlear hearing-impaired subjects the slopes of the level-loudness functions tended to increase with increasing hearing loss, indicating positive recruitment, whereas the much shallower slopes associated with retro-cochlear lesions were presumed to reflect negative recruitment. The graphic representation of the iso-loudness functions revealed a different dynamic range between Group 1 and 2 with the ability to discriminate small differences of stimulus levels reduced in the presence of an acoustic neuroma. Category loudness scaling has been shown to be a valuable tool describing the individual perception of sound in a qualitative and quantitative manner. Furthermore, the method can be employed as an indicator of recruitment without any restrictive preconditions. For this reason the categorical loudness scaling can be a desirable method for supplementing the audiological diagnosis of a retro-cochlear hearing impairment through the frequency-specific description of a usable hearing-field and its dynamic range.

Adult↗

Intensity coding in the auditory periphery of the cat: responses of cochlear nerve and cochlear nucleus neurons to signals in the presence of bandstop masking noise.

The dynamic range over which fine intensity discrimination is possible has been reported to be largely unaffected by limitation of the spread of neuronal activity to neighbouring frequency regions by bandstop noise masking. We have therefore examined the responses of cochlear nerve and nucleus neurons to tone and noise signals in the presence of a bandstop masking noise designed to be comparable to that employed in the psychophysical experiments. Under these conditions, the vast majority of cochlear nerve fibres were saturated by sound levels at which some 50% of our sample of cochlear nucleus neurons still responded to signal level differences. The extended dynamic ranges of these cochlear nucleus neurons was shown to be a result of activation, by the masking noise, of the lateral inhibitory side-bands 'biassing' the neuron's discharge. A small proportion of cochlear fibres, having low spontaneous discharge rates and showing strong two-tone suppression effects, demonstrated analogous but not so pronounced effects. It is unclear in what form information on the level of stimuli under these conditions is transmitted by the majority of apparently saturated cochlear nerve fibres, but several possible mechanisms are discussed.

Animals↗

Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation.

Preliminary evaluation of recently developed large-area flat panel detectors (FPDs) indicates that FPDs have some potential advantages: compactness, absence of geometric distortion and veiling glare with the benefits of high resolution, high detective quantum efficiency (DQE), high frame rate and high dynamic range, small image lag (< 1%), and excellent linearity (approximately 1%). The advantages of the new FPD make it a promising candidate for cone-beam volume computed tomography (CT) angiography (CBVCTA) imaging. The purpose of this study is to characterize a prototype FPD-based imaging system for CBVCTA applications. A prototype FPD-based CBVCTA imaging system has been designed and constructed around a modified GE 8800 CT scanner. This system is evaluated for a CBVCTA imaging task in the head and neck using four phantoms and a frozen rat. The system is first characterized in terms of linearity and dynamic range of the detector. Then, the optimal selection of kVps for CBVCTA is determined and the effect of image lag and scatter on the image quality of the CBVCTA system is evaluated. Next, low-contrast resolution and high-contrast spatial resolution are measured. Finally, the example reconstruction images of a frozen rat are presented. The results indicate that the FPD-based CBVCT can achieve 2.75-lp/mm spatial resolution at 0% modulation transfer function (MTF) and provide more than enough low-contrast resolution for intravenous CBVCTA imaging in the head and neck with clinically acceptable entrance exposure level. The results also suggest that to use an FPD for large cone-angle applications, such as body angiography, further investigations are required.

Angiography↗