Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Surgical Stapling”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

[Hemostasis in deep injuries of the liver].

Experimental and clinical substantiation of the use of an original alloyed staple with shape memory allowed it to be recommended for closure of deep wounds of the liver when all other known methods and constructions are ineffective. The staple causes a lesser zone of necrosis than that produced by catgut in closure of a similar wound, and it can be removed with no loss of blood. Consequently, its application is a method of today, causes little injury, and is promising.

Alloys↗

Bovine pericardium buttress limits recanalization of the uncut Roux-en-Y in a porcine model.

In contrast to the traditional Roux-en-Y reconstruction, an uncut Roux-en-Y provides biliopancreatic diversion and may preserve myoelectric continuity. Previous iterations of the uncut Roux have been plagued by recanalization of the uncut staple line in the afferent small bowel. Our aim was to determine if bovine pericardium buttress prevents recanalization of the stapled small bowel partition in a porcine model. Sixteen female pigs ( approximately 30 kg) underwent a side-to-side stapled jejunojejunostomy, 20 cm distal to the ligament of Treitz, with placement of a nondivided stapled partition with a single row of 2.5 mm width staples in the intervening jejunal loop. Nine animals in the experimental group had a bovine pericardium buttressed staple line (5 permanent, 4 absorbable), whereas seven animals in the control group had a nonbuttressed staple line. At 6 or 12 weeks, necropsy was performed and the primary outcome, staple line recanalization, was assessed grossly and histologically. Statistical analysis was performed by means of the chi-square test. There were no major complications and all animals gained weight. Overall, eight of nine bovine pericardium buttressed staple lines were grossly and histologically intact at necropsy, whereas all nonbuttressed uncut staple lines had recanalized completely (P<0.05). At 6 weeks, both permanent (N=4) and absorbable (N=3) buttress preparations prevented recanalization. At 12 weeks the permanent buttress remained closed (N=1), but the absorbable buttress had allowed partial recanalization (N=1). The use of bovine pericardium buttress will prevent small bowel recanalization of uncut small bowel staple lines at early follow-up. Pilot data at intermediate follow-up suggest permanent buttress is more durable than absorbable buttress. These results warrant investigation of bovine pericardium for intestinal applications in humans.

Anastomosis, Roux-en-Y↗

Breakdown of gastric staple line as a complication of the uncut Collis-Nissen fundoplication in children.

Uncut Collis-Nissen fundoplication for complicated gastroesophageal reflux was performed in 102 children (46 girls; age 5.6 +/- 4.2 years). Five patients developed intractable emesis postoperatively (average 11 +/- 5 months after surgery) and were found to have two independent luminal openings at the gastroesophageal junction seen on upper endoscopy but not demonstrable on upper GI. The defect was presumed to occur from breakdown of the original staple line on the lesser gastric curve. The condition was successfully repaired in all patients by including a new staple line and rewrapping of the stomach. Practitioners should be aware of this previously unreported complication post uncut Collis-Nissen fundoplication and that this condition may not be excluded by a normal upper GI study.

Child↗

The use of staple-line reinforcement during laparoscopic gastric bypass.

Divided linear staple-lines are a mainstay of gastrointestinal surgery, and in particular, bariatric surgery. Staple-line failure, although uncommon, can result in significant morbidity and even mortality. Staple-line buttressing has been developed to improve staple-line strength, decrease bleeding and minimize the risk of leak. Many different products are currently available. However, most have not been proven in clinical trials. Bovine pericardial strips (BPS) are a buttressing material that fits onto the stapler device and gets "stapled" onto the tissue when the device is fired. The strips add thickness and potentially strength to the staple-line. Animal research has shown that staple-lines incorporated with BPS had higher burst pressures than those without. Human experience has suggested that BPS decreased the risk of acute staple-line failures in laparoscopic Roux-en-Y gastric bypass surgery. This report reviews the clinical and research experience with this product.

Anastomosis, Roux-en-Y↗

Hand-assisted laparoscopic distal gastrectomy with regional lymph node dissection for gastric cancer.

Recently, a minimally invasive operation for gastric malignancies has been advocated, and the laparoscopic operation is noted as a technique that raises the quality of life. We performed distal gastrectomy with regional lymph node dissection by hand-assisted laparoscopic surgery for 60 cases of gastric cancer located in the middle or lower third of the stomach. Billroth I reconstruction was applied intracorporeally to the first 30 cases by using the double stapling method with a conventional circular stapling device, and in the final 30 cases, the quadrilateral (square) stapling technique with a laparoscopic linear stapling device was used to prevent postoperative anastomotic bleeding. This technique not only is less invasive, but also is similarly curative compared with open gastrectomy that was performed for 60 gastric cancer cases of similar staging before the beginning of this procedure.

Adult↗

Revisiting the biofragmentable anastomotic ring: is it safe in colonic surgery?

INTRODUCTION: The use of the biofragmentable anastomotic ring (BAR) has been reported in the literature with good results. Our purpose in this review was to document the clinical outcomes after gastrointestinal anastomoses performed with use of the BAR. METHODS: Data were gathered systematically through chart review with the help of data collection forms from 159 patients who underwent 173 intestinal anastomoses performed with use of the BAR between 1992 and 1999. Of the 165 patients who had anastomoses (6 had 2 anastomoses constructed on separate occasions and were considered separately), 23 (13.9%) had surgery with anastomosis under emergency conditions, and 44 (26.7%) were steroid-dependent patients. The indications for surgery were malignant disease in 63 (38.2%) patients, inflammatory bowel disease in 54 (32.7%) patients, diverticular disease in 13 (7.9%) patients and other conditions in 35 (21.2%) patients. RESULTS: A clinical anastomotic leak developed in the first 2 weeks after surgery in 7 (4.2%) patients, 6 of whom required reoperation. All recovered well, withno deaths related to use of the BAR. Early small-bowel obstruction developed in 13 patients (7.9%), none of whom required reoperation. The average postoperative length of hospital stay was 9.0 days, the average time to pass the first flatus was 3.2 days, and the average time to begin oral fluid intake was 3.3 days. The rate of leakage at the anastomosis in our series was comparable to that found in randomized trials with the BAR (2.0%-4.4%) and as reported with hand-sewn and stapled anastomoses (1.9%-8.2%). CONCLUSIONS: Our data indicate that use of the BAR is safe and effective in both elective and emergent surgery. The rate of leakage is comparable to that reported in the literature when a BAR is used.

Adolescent↗

Linear gastrectomy: an endoscopic staple-assisted anterior highly selective vagotomy combined with posterior truncal vagotomy for treatment of peptic ulcer disease.

A technique of anterior highly selective vagotomy is described that uses an endoscopic stapling device to facilitate and speed the procedure. Further study is necessary to ascertain the long-term recurrence rate for this new procedure, but it shows great promise as a simplified procedure for laparoscopic application in peptic ulcer disease.

Female↗

Pelvic pouch-anal anastomoses: pros and cons about omission of mucosectomy and loop ileostomy. A study of 60 patients.

Pelvic pouches were constructed in 60 consecutive patients from 1987 to 1991. The first 30 patients underwent mucosectomy and construction of handsewn reservoirs, and ileoanal anastomoses protected by loop ileostomy (group A). In the following 12 patients (group B1) J pouches and ileoanal anastomoses were constructed by total stapling technique without mucosectomy, with a loop ileostomy. In the last 18 patients the loop ileostomy was omitted (group B2). A comparison between group A and B and between group B1 and B2 was made concerning anaesthesia time, hospital stay, blood transfusions, postoperative complications and pouch function at 2 and 12 months. It was found that the stapling technique (group B) reduced anaesthesia time considerably and reduced the need of blood transfusions. Postoperatively thromboembolic episodes and signs of adrenal insufficiency were seen only in the handsewn group, while postoperative febrile conditions were more common in the stapled groups. Ileo-anal dehiscence occurred in two patients without loop ileostomy. Treatment by establishment of a loop ileostomy, local irrigation and administration of antibiotics were successful, the anastomoses healed within 2 weeks and there was no further complications before or after loop closure. Omitting the loop ileostomy saved the patient a further operation and reduces hospital stay and sick leave. After two months of pouch function, patients with handsewn pouches had a lower number of bowel movements (5.5/24 h and 0.8 during the night) than patients with stapled pouches (8.0/24 h and 1.9 during the night). At 12 months, however, the difference between the groups of patients had diminished.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Mechanically stapled esophagojejunostomy. Results of a prospective series of 176 cases.

BACKGROUND/AIMS: To evaluate the reliability of stapled esophagojejunostomy. MATERIAL AND METHODS: We studied a non-selected prospective series of 176 consecutive total gastrectomies (169 cancers, 7 benign pathologies). RESULTS: Hand-sewn esophagojejunostomy was performed 5 times after failure of the stapled esophagojejunostomy. There were fourteen hospital deaths (8%), and 63 patients (36%) presented complications. There were 5 anastomotic leaks (2.8%) but non were responsible for deaths. In these 5 cases, there had been an incident during construction of the esophagojejunostomy. Such an incident was the only significant risk factor for an anastomotic leak: 17% after an incident and 0% in the absence of an incident (p < 0.001). We observed no cases of anastomotic stricture. CONCLUSION: Stapled esophagojejunostomy is a reliable technique when technical precautions are taken. It is easier to reproduce than hand-sewn esophagojejunostomy and has demonstrated low specific morbidity and no direct mortality.

Adult↗

Tissue response to biomaterials used for staple-line reinforcement in lung resection: a comparison between expanded polytetrafluoroethylene and bovine pericardium.

OBJECTIVE: A study in a canine model of lung-reduction surgery evaluated the tissue response to polytetrafluoroethylene (ePTFE) and bovine pericardium (BP) used for staple-line reinforcement. METHODS: In each of ten dogs, BP was placed in one lung and ePTFE in the other. The implants were retrieved at 30, 95, or 167 days after implantation and studied histologically. The connective tissue covering the implants was measured and analysis of variance was used to compare results with the two materials. RESULTS: At 30 days, the BP specimens showed focal chronic inflammation and thin tissue coverage, whereas the ePTFE specimens had no focal inflammation and thick tissue coverage. At 95 and 167 days, the inflammation in the BP specimens had resolved, but tissue coverage remained minimal, and there was no resorption of the BP. In the ePTFE specimens, tissue coverage had increased. Analysis of variance comparing representative tissue specimens showed that the tissue encapsulating the ePTFE was significantly thicker than that surrounding the BP (P < 0.0001). No air leaks, staple-line disruptions, or infections occurred in the study. CONCLUSIONS: Neither ePTFE nor BP is resorbable. Both materials have been used successfully, without resultant infections, for clinical staple-line reinforcement. The more favorable tissue response to ePTFE observed in this study may have clinical ramifications. Comparative clinical studies of the two materials are needed.

Analysis of Variance↗

Endoscopic stapling of pharyngeal pouches in patients from the Yorkshire region.

The treatment of pharyngeal pouches by endoscopic stapling diverticulotomy has gained popularity over the last few years. We assessed the results of this technique in 44 patients by means of a clinical questionnaire and by reviewing case records. Thirty-six (82 per cent) patients commenced oral intake within 18 hours of the procedure and 37 (84 per cent) patients were discharged within 48 hours. Five patients had complications that included throat discomfort, a loose incisor tooth, shoulder pain, pharyngeal perforation and one mortality due to mediastinitis. Of the 37 patients that completed the questionnaire, nine (24 per cent) had some residual symptoms although only two (five per cent) felt that there had been no improvement at all following the stapling procedure. Thirty-five (95 per cent) of the patients stated that they would undergo the procedure again. It appears that pharyngeal pouches can be successfully treated by endoscopic stapling, with patients commencing oral intake within a few hours of surgery and having a short hospital stay. However, as there can be serious complications, we recommend that the procedure be performed by an experienced surgeon.

Aged↗

Conversion of failed vertical banded gastroplasty to open adjustable gastric banding.

BACKGROUND: Occasionally, patients with failed vertical banded gastroplasty (VBG) present for secondary treatment. We performed the reoperations using adjustable gastric banding (AGB) technique. METHODS: From 1991 to 1997, 80 morbidly obese patients underwent VBG. In 7 (8.7%), staple-line disruption and weight regain were detected within 2 years of follow-up. Conversion to AGB was performed between 1994 and 1998. Meanwhile, another 80 morbidly obese patients underwent primary open AGB. RESULTS: In the 7 patients, staple-line disruption was seen on radiography as a leak of contrast material across the gastric partition. After conversion of "failed" VBGs to AGB, postoperative results have been very satisfactory and similar to those of the primary open AGB group. CONCLUSIONS: VBG is a safe technique, although conversion rates were significant. Staple-line disruption constituted the chief cause of insufficient weight loss and frequently indicated the need for further surgery. Our results of the revisional surgery confirm that the reoperations for failed VBG can be performed using AGB technique.

Body Mass Index↗

Reinforcing gastric staple-lines with bovine pericardial strips may decrease the likelihood of gastric leak after laparoscopic Roux-en-Y gastric bypass.

BACKGROUND: Staple-line leakage is a potentially devastating complication of Roux-en-Y gastric bypass (RYGBP). Bovine pericardial strips (BPS) have been used to reinforce staple-lines in pulmonary resections and have been shown to decrease air-leaks. This study examined the use of BPS to decrease gastric staple-line leaks. METHODS: 250 consecutive patients undergoing laparoscopic RYGBP had BPS used for the gastric pouch. Ease of use, operative complications, and visual bleeding were recorded. In addition, the postoperative leak rate was compared to 100 consecutive patients operated on prior to the study when BPS was not used. RESULTS: Patient characteristics were the same for both groups and comparable with most published data. With the use of BPS, there were no operative complications and no meaningful increase in operating time. BPS reinforced staple-lines had no visual bleeding. In the 100 cases without BPS, there were 2 staple-line leaks (2%) both of which required emergency exploration. One additional patient was subsequently found to have a gastrogastric fistula. In the 250 patients who had BPS-reinforced staple-lines, there were no acute leaks. Three patients were subsequently found to have gastrogastric fistula. None required emergency surgery. CONCLUSION: In this non-randomized trial, BPS were found to be easy and safe to use. In addition, staple-line hemorrhage was essentially non-existent. Although the reduction in gastric staple-line leak rate may also be attributed to learning curve, there were no acute leaks in 250 patients with BPS, which is below the published norms.

Adult↗

Early gastrointestinal hemorrhage after laparoscopic gastric bypass.

BACKGROUND: Early gastrointestinal (GI) hemorrhage after open gastric bypass has been infrequently reported. The aim of this study was to examine the incidence of early GI hemorrhage after laparoscopic Roux-en-Y gastric bypass (LRYGBP), its presentation, and possible treatment options. METHODS: A retrospective review of 5 patients who developed early postoperative GI hemorrhage after LRYGBP was performed. The charts were reviewed for demographics, clinical presentation, diagnostic evaluation, and treatment. All patients underwent a transected LRYGBP with creation of the gastrojejunostomy anastomosis with a circular stapler and the jejunojejunostomy anastomosis with a linear stapler. RESULTS: Of the 155 patients in our database who underwent LRYGBP, 5 (3.2%) developed early clinical GI hemorrhage. There were 2 males with an average age of 40 years. Clinical presentations of GI hemorrhage were hematemesis (2 patients), bright red blood per rectum (1 patient), melena (1 patient), and hypotension (1 patient). A diagnostic study (nuclear scintigraphy) was performed in only 1 of 5 patients. 3 of 5 patients were managed nonoperatively; 2 patients required fluid and blood resuscitation, and the other patient was managed without blood transfusion. The onset of hemorrhage in these 3 patients occurred 24 hours postoperatively or later. 2 of 5 patients required operative intervention for control of hemorrhage. The onset of hemorrhage or hypotension in these 2 patients occurred within 12 hours after surgery. The sites of hemorrhage were at the gastric remnant staple-lines in 1 patient and at the gastrojejunostomy and gastric remnant staple-lines in the other patient. CONCLUSION: Early GI hemorrhage is a potential complication after transected LRYGBP. Early reoperative intervention should be performed for patients with hemodynamic instability and patients with early onset of hemorrhage after surgery.

Adult↗

Functional results of the double-stapled ileoanal reservoir.

BACKGROUND: The preferred method for creation of an ileoanal reservoir is still controversial. We prospectively studied the functional and physiologic outcome of our patients who underwent a double-stapled ileoanal reservoir (DSIAR). STUDY DESIGN: All consecutive patients who underwent restorative proctocolectomy with a DSIAR between 1988 and 1993 were evaluated. Functional results were assessed by questionnaires and anal manometry preoperatively and two, 12, and 24 months postoperatively. RESULTS: One hundred forty patients (90 males and 50 females) with a mean age of 40.7 (range, 12 to 71) years were evaluated. Of these, 107 patients (77 percent) had ulcerative colitis, 21 (15 percent) had familial adenomatous polyposis, six (4 percent) had indeterminate colitis, and six (4 percent) had a post-operative diagnosis of Crohn's disease. One hundred twenty-four (95 percent) of the 131 patients with closed stomas were available for functional and manometric evaluation at a mean follow-up period of 24 months. A 32 percent decline in the mean resting pressure (from 71.3 +/- 4 to 48.2 +/- 3.4 mm Hg) occurred early after DSIAR (p < 0.001) with partial recovery by 24 months. The maximal internal sphincter resting pressure showed a 39 percent decline (from 90.8 +/- 4.9 to 55.3 +/- 5.7 mm Hg, p < 0.005) with recovery after 12 months. There were no significant changes in the length of the high-pressure zone or mean or maximal squeeze pressures. A mean of 5.4 (two to 13) bowel movements occurred during the day and a mean of 1.2 (zero to four) occurred at night. Perfect or almost perfect continence was reported during the day and night, respectively, by 95 and 92 percent of the patients. Overall perioperative complications occurred in 30 patients (21 percent) including septic complications in eight (6 percent), and pouchitis in eight (6 percent). There was one postoperative death (0.7 percent). CONCLUSIONS: Double-stapled ileoanal reservoir is associated with good subjective functional and objective physiologic results and has acceptable rates of morbidity and mortality.

Adenomatous Polyposis Coli↗

Creation of the LeBag orthotopic bladder using absorbable staples.

Absorbable stapling devices have been described by several groups for the creation of continent urinary diversions. Experience with these devices in the creation of the LeBag ileocecal orthotopic pouch is described. Use of the staplers simplifies pouch construction and yields functional results similar to hand-sewn reservoirs.

Cecum↗

Dual endoscopic-assisted endoluminal colostomy reversal: a feasibility study.

BACKGROUND: Emergent colostomies are associated with increased morbidity related to second closure operations. The purpose of this canine pilot study was to create a minimally invasive procedure that would reduce the time interval and morbidity involved with colostomy reversals after left colon end colostomies. METHODS: Six mongrel dogs underwent modified laparoscopic Hartmann's procedures in which the stapled end of the rectal stump was approximated to the left colon proximal to the stoma. After 1 week, they underwent an endoluminal colostomy reversal with a computer-mediated, circular stapling device and varying anvil insertion methods. Variables recorded included anvil insertion technique and feasibility, OR time, complications, and number of days to first meal and bowel movement. A contrast enema performed 1 week post colostomy reversal ruled out anastomosis leaks and stenosis. The dogs were euthanized and subjected to necropsy. RESULTS: Of four anvil insertion techniques tested, the most feasible employed a large-bore needle to perforate through the stapled end of the Hartmann pouch into the lumen of the left colon. Simultaneous endoluminal views of the rectal stump with a sigmoidoscope and the left colon lumen with an endoscope permitted a controlled and safe needle puncture. Through the needle, a guide wire was inserted to withdraw the anvil via the colostomy into place. A transanally inserted stapler was then married to the anvil under fluoroscopic guidance, thus completing the anastomosis. The colostomy was then taken down and transected at the level of the colocolostomy. Average operating time was 126 min (range 90-180), diet was tolerated within 1.5 days, and average number of days to first bowel movement was 2.5. The absence of stenosis, leaks, and inadvertent visceral injuries confirmed feasibility. CONCLUSIONS: In this canine model, a dual endoscopic-assisted colostomy reversal with a computer-mediated, circular stapling device is feasible. Using this technique, colostomy reversals can possibly be performed 1 week post-colostomy without entering the peritoneal cavity, thus reducing the number of invasive operations and subsequent morbidity required to manage emergent colon perforations.

Anastomosis, Surgical↗