Gravity-driven millifluidic platform for magnetic solid-phase extraction of Enterocytozoon hepatopenaei DNA from complex shrimp hepatopancreas.

Effective detection of Enterocytozoon hepatopenaei (EHP) in aquaculture is currently hindered by the lack of field-deployable extraction methods capable of processing complex, inhibitor-rich hepatopancreatic tissue. This study presents a gravity-driven millifluidic platform for the rapid extraction of EHP genomic DNA using an optimized, surfactant-compatible magnetic solid-phase extraction (MSPE) chemistry. Utilizing 5% PEG 8000 and 2.0 M NaCl, the platform facilitates the selectively capture of DNA from inhibitor-rich crustacean lysates. The 3D-printed device employs a tilting rocking plate to generate passive, gravity-driven flow, maintaining homogeneous magnetic bead suspension and maximizing solid-phase capture efficiency without external pumps. The integrated platform achieved a DNA yield of 2804.33 ± 15.31 ng/μL, a 5.9-fold increase over manual magnetic bead extraction. TaqMan quantitative PCR (qPCR) validation targeting the EHP SSU rRNA gene was developed. Using a standard curve spanning 101 to 107 plasmid copies (Ct = -3.611 log10 [copy] + 42.309, R2 = 0.998, amplification efficiency 89.2%), the on-chip MSPE achieved a validated analytical limit of detection (LOD) of 1 spore per reaction (100% detection rate, n = 21), whereas a commercial CTAB-based DNA extraction kit failed to achieve a validated LOD even at 10 spores (85.7%, 18/21). Nested PCR targeting the SWP gene was employed for field evaluation. A pilot study across two cohorts (N = 40) demonstrated consistent detection of confirmed EPH-positive cases; however, the small sample size precludes definitive diagnostic accuracy claims. With a total processing time under 30 min, this platform provides a high-efficiency extraction module. Future work will couple the device with isothermal amplification (e.g., LAMP or RPA) to realize a sample-to-answer system for resource-limited aquaculture.

Aquaculture diagnostics↗

Rapid and sensitive quantification of urinary N7-methylguanine by isotope-dilution liquid chromatography/electrospray ionization tandem mass spectrometry with on-line solid-phase extraction.

A rapid, highly specific and sensitive isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with an on-line solid-phase extraction (SPE) system was developed to measure N7-methylguanine (N7-MeG) in urine. 15N5-Labeled N7-MeG was synthesized to serve as an internal standard, and an on-line SPE cartridge was used for on-line sample cleanup and enrichment. The urine sample can be directly analyzed within 15 min without prior sample purification. The detection limit for this method was estimated as 8.0 pg/mL (4.8 pmol) on-column. This method was further applied to study exposure to methylating agents arising from cigarette smoke. Sixty-seven volunteers were recruited, including 32 regular smokers and 35 nonsmokers. Urinary cotinine, a major metabolite of nicotine, was also determined using an isotope-dilution LC/MS/MS method. The results showed that urinary levels of N7-MeG observed in smokers (4215 +/- 1739 ng/mg creatinine) were significantly (P < 0.01) higher than those in nonsmokers (3035 +/- 720 ng/mg creatinine). It was further noted that the urinary level of N7-MeG was found to be correlated with that of cotinine for smokers, implying that cigarette smoking resulted in increased DNA methylation, followed by depurination and excretion of N7-MeG in urine. As a result of the on-line extraction system, this method is capable of routine high-throughput analysis and accurate quantitation of N7-MeG, and could be a useful tool for health surveillance of methylating agent exposure.

Adult↗

Preparative separation and determination of matrine from the Chinese medicinal plant Sophora flavescens Ait by molecularly imprinted solid-phase extraction.

Molecularly imprinted microspheres (MIMs) were synthesized by micro-suspension polymerization using matrine (MT) as template. The MIMs were employed for solid-phase extraction (SPE) and as chromatographic stationary phase for the determination of MT from the Chinese medicinal plant Sophora flavescens. The effects of the various eluents, their concentrations and volumes on the retention behavior were investigated. The selectivity and capacity of the imprinted microspheres against MT was also discussed. The results showed that the MIMs exhibited stronger specific affinity to MT than to oxymatrine (OMT). Methanol-water (3:7, v/v) was used for washing impurities from the MIMs-SPE cartridge loaded with the herb extracts, while methanol-glacial acetic acid (9:1, v/v) was used for eluting MT. The maximum load of MT and the recovery of MIMs cartridge towards MT were 38.7 microg g(-1) and 71.4%, respectively. The method developed might be used to separate and extract effective constituents from Chinese medicinal plants on a large scale.

Alkaloids↗

Optimization of solid-phase extraction procedure for determination of polychlorinated dibenzo- p-dioxins, polychlorinated dibenzofurans, and coplanar polychlorinated biphenyls in humic acid containing water.

A solid-phase extraction (SPE) method was optimized for accurate determination of polychlorinated dibenzo- p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and coplanar polychlorinated biphenyls (CoPCBs) in humic acid containing surface water. Recovery experiments using humic materials revealed that humic acids permit dioxins to pass through an octadecylsilica (C(18)) extraction disk by associating with them under weakly alkaline conditions. Acidification of the sample before percolation improved this otherwise insufficient recovery. The analysis of surface water acidified to pH 2 gave better recovery with surrogate standards and lower quantitative values for higher-chlorinated homologues than the sample at pH 9. In all samples, the native octachlorodibenzo- p-dioxin (OCDD) peak abundance showed no difference between at pH 2 and at pH 9, indicating overestimation of the quantitative value of the homologue at pH 9. Acidification of a humic acid containing water sample can avoid overestimation of higher-chlorinated congeners caused by insufficient recovery of their corresponding surrogates.

Chromatography↗

Determination of 4-aminopyridine in serum by solid-phase extraction and high-performance liquid chromatography.

An assay for the determination of 4-aminopyridine in serum has been developed using 3,4-diaminopyridine as internal standard and reversed-phase high-performance liquid chromatography with detection at 244 nm. A mobile phase of acetonitrile-methanol-ethanol-1% ammonium carbonate (75:10:10:5) provided excellent separation of both compounds. Samples were extracted on solid-phase columns. The linearity, precision, recovery and the limit of detection were all sufficient for the routine use of this assay in clinical studies of patients treated with 4-aminopyridine.

4-Aminopyridine↗

Solid-phase extraction for the high-performance liquid chromatographic determination of indomethacin, suxibuzone, phenylbutazone and oxyphenbutazone in plasma, avoiding degradation of compounds.

A solid-phase extraction method was validated for the simultaneous high-performance liquid chromatographic determination of indomethacin, suxibuzone, phenylbutazone, oxyphenbutazone and their degradation products. Indomethacin was added as internal standard to plasma samples, which were then acidified with citrate buffer and passed through a phenyl cartridge. The drugs were eluted with hexane-diethyl ether (1:1, v/v), and the organic extract was taken to dryness. The residue was dissolved in methanol and chromatographed on a C18 column with ultraviolet detection at 240 nm. The elution was isocratic with a mobile phase of 0.02 M ammonium sulphate-acetonitrile (45:55, v/v), pH 3. For indomethacin, suxibuzone, phenylbutazone and oxyphenbutazone the limit of quantitation was 0.05 microgram/ml. The linearity was checked between 0.05 and 100 micrograms/ml (r = 0.999); within this range the recovery was higher than 90% and the accuracy showed relative errors of less than 7.5%. The main advantage of this method is the avoidance of degradation by using citrate buffer instead of the usual 5 M hydrochloric acid to acidify the plasma. The method is also more specific and less time-consuming than the previously reported liquid-liquid extraction, and could possibly be automated.

Anti-Inflammatory Agents, Non-Steroidal↗

Multi-walled carbon nanotubes as a solid-phase extraction adsorbent for the determination of chlorophenols in environmental water samples.

Multi-walled carbon nanotubes (MWCNs) are used as adsorbent for solid-phase extraction (SPE) of several chlorophenols (CPs). CPs were adsorbed on MWCNs cartridge, then desorbed with pH 10.0 methanol, finally determined by HPLC. Under the optimized conditions, detection limits of 0.08-0.8 ng mL(-1) were obtained. The method had been applied to analyze the five CPs in tap water and river water.

Adsorption↗

Fractionation of red wine polyphenols by solid-phase extraction and liquid chromatography.

A systematic method for separation of aged red wine polyphenols into various distinct fractions using combined techniques of solid-phase extraction and liquid chromatography was proposed. The aged red wine polyphenols were separated into various distinct fractions including phenolic acid fraction, monomer flavanol fraction, oligomer procyanidin fraction, anthocyanin and its pyruvic acid derivative fraction, free or non-colored proanthocyanidin fraction, fraction of direct condensation products between anthocyanins and proanthocyanidins and fraction of other pigmented complexes. The phenolic composition of each fraction was verified by HPLC with diode array detection (HPLC-DAD), thiolysis, vanillin assay, HPLC coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) and multi-stage MS fragment analysis. For the first time, anthocyanins and their pyruvic derivatives were separated from other phenolic compounds, while free or non-pigmented polymer proanthocyanidins from other pigmented complexes. The fractionation method would be of particular interest in further studying the detailed composition of polymeric polyphenols in red wine.

Chemical Fractionation↗

Graphitized carbons for solid-phase extraction.

The objective of this review is to provide updated information about the most important features of graphitized carbonaceous sorbents used for solid-phase extraction (SPE) of organic compounds from liquid natural matrices or extracts. The surface characteristics of graphitized carbon blacks and porous graphitic carbons are described which are responsible for the various types interactions (hydrophobic, electronic and ion-exchange) with analytes. The method development is given which is based on the prediction from liquid chromatographic retention data obtained using porous graphitic carbon. Emphasis is placed on their capability for trapping very polar and water-soluble analytes from aqueous samples. Comparison is made between carbon-based SPE sorbents and other reversed-phase materials such as octadecyl silicas and highly cross-linked copolymers. Especially, the difficulty encountered for the desorption of some strongly retained analytes is explained by LC data and solutions are given for optimizing the composition and volume of the desorption solution. Many examples illustrate the various common features of graphitized carbons which are the extraction of very polar analytes and multiresidue extractions. Some applications are specific to graphitized carbon black due to the presence of surface functional groups. They include the extraction of anionic compounds such as benzene and naphthalene sulfonates or acidic pesticides. Other applications are specific to porous graphitic carbon due to its flat and homogeneous surface. One example is the trace extraction of coplanar polychlorinated biphenyls (PCBs), dibenzo-p-dioxins and dibenzofurans from other PCB congeners.

Chromatography, Liquid↗

Update on solid-phase extraction for the analysis of lipid classes and related compounds.

This article provides information on the different procedures and methodologies developed when solid-phase extraction (SPE) is used for lipid component separation. The analytical systematics, established by different authors and designed to separate groups of compounds and also specific components by using a combination of chromatographic supports and solvents are presented. The review has been divided into three parts, which we consider well defined: edible fats and oils, fatty foods and biological samples. Separations of non-polar and polar lipids is the most extensive systematic, although many other published methods have been established to isolate specific components or a reduced number of components from edible fats and oils, fatty foods or biological samples susceptible to further analysis by other quantitative techniques.

Chromatography↗

Analysis of mono- and diesters of o-phthalic acid by solid-phase extractions with polystyrene-divinylbenzene-based polymers.

Retention mechanisms of an unmodified and a hydroxylated polystyrene-divinylbenzene polymer were studied by solid-phase extraction of o-phthalic acid and some of its mono- and diesters from purified water and then analysing by GC-MS. The monoesters and phthalic acid were retained only when protonated (i.e. acidified with HCI to pH 0.9). Of all elution solvents tested, ethyl acetate gave the best overall recoveries (61-89%) with both polymers. Applicability to complex matrixes (e.g. acidogenic landfill leachates) was examined by introducing a washing step with acetone in acidified water (pH 0.9) to eliminate volatile fatty acids (C2-C6) from the cartridge. Finally, the method was tested on real samples.

Esters↗

Application of porous carbon for solid-phase extraction of dicarboxyimide fungicide residues from wines in combination with high-resolution capillary gas chromatography and gas chromatography-mass spectrometry.

Solid-phase extraction with a novel porous carbon sorbent CARB GR was used for the clean-up step of dicarboxyimide fungicides residues from variety of Slovak grape wines with subsequent capillary gas chromatography-flame ionization detection, -electron-capture detection (ECD) and -mass spectrometry-ion-trap detection (MS-ITD) analysis. Recovery was tested at various concentration levels of vinclozolin and iprodione in standard solutions (R = 80-97%, R.S.D. < or = 5). The value of recovery in spiked wines is dependent on concentration level (studied in the range of 5.9 micrograms/1-1.96 mg/l) and on the variety of wine (R = 80-96%; R.S.D. = 3-5%). Limits of quantitation (for sample volume 50 ml) were determined to be with GC-ECD for both fungicides in ppt range and with GC-MS-ITD in the multiple ion detection mode monitoring in ptt range for vinclozolin and ppb range for iprodione. Concentration levels of vinclozolin residues were determined in treated wines (with 0.1% Ronilan 50 WP) as well as iprodione residues (with 0.15% Rovral 50 WP) and a strong dependence on the protective term before the harvest is shown.

Aminoimidazole Carboxamide↗

Stability of pesticides stored on polymeric solid-phase extraction cartridges.

The stability of four pesticides (desethylatrazine, fenamiphos, fenitrothion and fonofos) was examined under different storage conditions after preconcentration in disposable solid-phase extraction (SPE) cartridges containing new polymer sorbent materials (Hysphere-1, IST EnviroLut and LiChrolut). Complete recovery for all the compounds was observed in precolumns kept at -20 degrees C for 1 month when preconcentrating 26 ml of ground water sample spiked at 10 micrograms/l. Degradation of fenamiphos and fenitrothion occurred in precolumns stored at 4 degrees C and at room temperature after 1 month. Fonofos was stable when compared to their storage in C18 precolumns. Problems in the quantification of the analytes after storage at 4 degrees C and at room temperature were encountered due to the presence of many interfering peaks in the chromatograms. Analysis of blanks with C18 precolumns was carried out, to determine the interferences. The stability of the pesticides was also examined in acidifed and non-acidified ground water in order to compare it to the stability of pesticides stored on SPE cartridges. Significant losses of fenamiphos and fenitrothion were achieved and were related to the pH of the water sample and their chemical structure. Finally, the new polymeric sorbent Hysphere-I was evaluated in terms of breakthroughs and compared with those of C18, obtaining higher recoveries for desethylatrazine.

Atrazine↗

Determination of tocopherols and sterols in vegetable oils by solid-phase extraction and subsequent capillary gas chromatographic analysis.

In general, analyses of tocopherols and sterols are performed separately in vegetable oils. By applying solid-phase extraction (SPE) prior to capillary gas chromatography, a simple and reliable procedure for the quantification of both tocopherols and sterols in a single analytical run has been developed. SPE was used as sample clean up procedure for the separation of these minor components from the triacylglycerol matrix, replacing time consuming saponification or on-line LC-GC. The analysis of tocopherols and free sterols in five different vegetable oils illustrates robustness and reliability of this method outlined. Quantification of the analytes was performed by external calibration with reference substances and internal standardization. The recovery of the procedure as well as the repeatability of the quantitative results have been evaluated.

Calibration↗

Multiresidue methods using solid-phase extraction techniques for monitoring priority pesticides, including triazines and degradation products, in ground and surface waters.

The review describes the use of solid-phase extraction (SPE) techniques for monitoring priority pesticides in ground and surface waters. The focus is on triazine herbicides and their degradation products. Data concerning the fate, occurrence, properties and extraction of triazines and their degradation products using different SPE techniques are tabulated and discussed.

Chromatography↗

Determination of phenolic flame-retardants in human plasma using solid-phase extraction and gas chromatography-electron-capture mass spectrometry.

A method for determination of phenolic flame-retardants in human plasma utilizing solid-phase extraction (SPE) and gas chromatography with electron-capture mass spectrometric detection (GC-ECMS), has been developed. The plasma lipids were decomposed by application of concentrated sulphuric acid directly on the polystyrene-divinylbenzene SPE column. The method has been validated for 2,4,6-tribromophenol (TriBP), pentabromophenol (PeBP), tetrachlorobisphenol-A (TCBP-A) and tetrabromobisphenol-A (TBBP-A) in the concentration range 1.2-25, 0.4-40, 4-200 and 4-200 pg g(-1) plasma, respectively. The average absolute recovery of the analytes ranged from 51 to 85%. Tetrabromo-o-cresol and chlorotribromobisphenol-A were found suitable as internal standards, and the average recovery of the analytes relative to the internal standards was in the range 93-107%. The repeatability of the method was in the range 4-30% relative standard deviation. The estimated detection limits of TriBP, PeBP, TCBP-A and TBBP-A were 0.3, 0.4, 3.0 and 0.8 pg g(-1) plasma, respectively. The method has been used for analysis of plasma samples from potentially occupationally exposed human individuals.

Flame Retardants↗

Solid-phase extraction and liquid chromatographic quantitation of the antiarrhythmic drug L-768673 in a microemulsion formulation.

A sensitive and specific method based in solid-phase extraction and reverse-phase liquid chromatography was developed and validated for the quantitation of L-768673 in a microemulsion formulation. Following a water wash, the drug was eluted from the extraction column with acetonitrile and was analyzed on a reverse-phase C18 column with UV detection at 245 nm. The mobile phase consisted of acetonitrile-0.2% trifluoroacetic acid, 0.1% triethylamine (53:47 v/v). The retention time L-768673 was approximately 28 min with a flow rate of 1.5 ml min-1.

Acetamides↗

Tandem-cartridge solid-phase extraction followed by GC/MS analysis for measuring partition coefficients of association of polycyclic aromatic hydrocarbons to humic acid.

A tandem-cartridge solid-phase extraction system combining reversed-phase separation and dynamic ion exchange followed by GC/MS analysis was studied for measuring partition coefficients (Kdoc) of association of polycyclic aromatic hydrocarbons (PAHs) to humic acid. Time course batch experiments revealed that the association of PAHs to humic acid included a slow stage with equilibrium time of 5-7 days. The disequlibrium and retention of the PAH-humic acid associate during reversed-phase separation lead to systematic negative error for the measured partition coefficients; more accurate results were achieved with a three-cartridge tandem system in which the negative error was assessed and corrected via the PAH analytes measured on the second reversed-phase cartridge. The potential and advantages of use of C18 disk cartridges instead of conventional C18 cartridges to set up the tandem system for measuring the partition coefficients were also studied. With the tandem-cartridge system, the measured partition coefficients did not change with most experimental conditions, but a trend of decreasing partition coefficients with humic acid concentration was observed, implying possible nonlinear association of the PAHs and humic acid.

Environmental Pollutants↗