Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Slit Lamp”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

[Ophthalmoscopic assessment of the size of the optic nerve papilla].

PURPOSE: To examine whether the optic disc size can be measured with common ophthalmoscopic lenses. PATIENTS AND METHODS: The horizontal and vertical disc diameters in 125 eyes of 65 patients were measured ophthalmoscopically using a commercial slit lamp with adjustable length of the beam and a Volk 60 diopters lens or a Volk Superfield lens. The refractive error of the subjects ranged between -7.25 D and +3.25 D (mean +/- S.D.: -0.34 +/- 1.77). Based on these measurements we calculated the optic disc area by applying a modified formula for an ellipse, where area = horizontal diameter x vertical diameter x pi/4. Additionally, we measured planimetrically the horizontal and vertical diameters of the optic disc on color stereo disc photographs after correcting the ocular and camera magnification according to Littmann's method. RESULTS: The values of the horizontal and vertical disc diameters evaluated on the photographs were by factors of 1.0 and 1.5 larger than those values measured with the Volk 60 D lens, and the Volk Superfield lens, respectively. Taking into account these constant linear correction factors, the optic disc diameters as measured by the Volk 60 D lens and the Volk Superfield lens varied by 0.11 +/- 0.09 mm (5.9 +/- 5.1%), and 0.11 +/- 0.09 mm (5.9 +/- 4.9%), respectively, from the values measured on the photographs. The error for the ophthalmoscopic measurement of the disc diameters decreased slightly with increasing disc size. With highly myopic eyes excluded, it was independent of the refractive error. CONCLUSION: For clinical purposes, the optic disc and other structures of the posterior fundus can be determined by ophthalmoscopy using a slit lamp and commonly used ophthalmoscopical lenses.

Adult↗

Relevance of intraocular involvement in the management of primary central nervous system lymphomas.

BACKGROUND: Reported data regarding intraocular lymphoma (IOL) management are anecdotal. Cases of IOL included in an international multicentre series of 378 immunocompetent patients with primary central nervous system lymphomas (PCNSLs) were reviewed. PATIENTS AND METHODS: Staging included slit-lamp examination in 170 patients: IOL was diagnosed in 22 cases (13%). A concomitant brain lesion was detected in 21 cases. Planned treatment was chemotherapy followed by radiotherapy in 13 cases, chemotherapy alone in three and radiotherapy, followed by or not by chemotherapy in five; one patient was not treated. Chemotherapy included high-dose methotrexate in 12 cases. Ten patients received intrathecal chemotherapy. Radiotherapy consisted of whole brain irradiation, followed by or not by a tumour bed boost; ocular irradiation was planned in 15 cases. Irradiation in one patient without brain lesions was limited to the orbits only (50 Gy). RESULTS: IOL was positively correlated to systemic symptoms and meningeal disease. Fifteen patients (71%) achieved an objective response; 16 patients experienced a failure (2-year failure-free survival 34+/-10%). Failures involved the eyes in eight cases, with a 2-year time to ocular relapse of 59+/-11%. Ocular failure was less common in patients treated with chemotherapy plus ocular irradiation and was associated with a significantly shorter survival. Seven patients are alive [median follow-up 53 months, 2-year overall survival (OS): 39+/-11%] , five of whom were treated with ocular irradiation. The patient with isolated IOL is alive and disease-free at 14 months. OS of the entire series was similar to that of PCNSL patients with negative slit-lamp examination. CONCLUSIONS: IOL is usually associated with concomitant brain disease and shows a survival similar to that of the rest of PCNSLs. Chemotherapy combined with ocular irradiation resulted in better control of ocular disease, which seems to be associated with survival. In view of the potential role of ocular irradiation, the use of chemotherapy alone in phase II trials should be critically reconsidered in PCNSL patients with ocular disease.

Adolescent↗

Quantitative vitreous fluorophotometry applying a mathematical model of the eye.

A slit-lamp fluorophotometric method is presented that permits calculation of a blood-retinal barrier permeability to fluorescein (P) and a diffusion coefficient for fluorescein in the vitreous body (D). The calculations are performed by relating the time course of the free--not protein bound--fluorescein concentration in the bloodstream with the fluorescein concentration profile in the vitreous body. The combination is performed automatically on a computer by applying a simplified mathematical model of the eye. P refers to the area of the barrier of the model eye. In a group of six normal persons, the mean P was (1.1 +/- 0.4) X 10(-7) cm/sec (mean +/- SD), while in six diabetic patients with background retinopathy and macular edema the mean P was (7.1 +/- 3.8 ) X 10(-7) cm/sec. The mean D was (7.4 +/- 3.4) X 10(-6) cm2/sec in the normal group and (9.6 +/- 2.0) X 10(-6) cm2/sec in diabetic patients, corresponding as a first approximation to free diffusion in water. Model calculations show that knowing the fluorescein concentration in the bloodstream is considerably significant for the calculation of the permeability, contributing factors up to 50%. For the low-permeation situation, subtraction of the preinjection scan contributes a factor of 50% for both permeability and diffusion coefficient. The exact placement in the vitreous body of the concentration profile, by applying a formalism that transforms slit-lamp movement to intraocular distance, contributes a factor of 20% on the diffusion coefficient. The permeability obtained with the model can be calculated as the ratio between area of vitreous and plasma fluorescein concentration curves within 20%. Active transport of fluorescein across the blood-retinal barrier in the direction of vitreous to blood does not seem to be significant within the first 2 hr after fluorescein injection.

Blood Physiological Phenomena↗

Effect of heparin-surface-modified intraocular lenses on postoperative inflammation after phacoemulsification: a randomized trial in a United States patient population. Heparin-Surface-Modified Lens Study Group.

OBJECTIVE: To compare postoperative inflammation occurring with heparin-surface-modified (HSM) versus non-HSM polymethyl methacrylate intraocular lenses (IOLs) after phacoemulsification. DESIGN: Randomized, double-masked, multicenter, parallel trial. PARTICIPANTS: A total of 367 patients, consisting of routine (n = 220), glaucoma (n = 58), and diabetes (n = 89) patients, from eight US medical centers. METHODS: Patients were observed for 1 year after phacoemulsification and lens implantation (week 1, months 1, 3, 6, 12). MAIN OUTCOME MEASURES: Primary measures of postoperative inflammation defined as the presence of giant cells on the lens surface via specular micrography and cellular deposits via slit-lamp examination. RESULTS: The cross-sectional analyses showed that consistently fewer routine patients with HSM lens implants had giant cells on the IOL than those with non-HSM lens implants across all follow-up visits. The statistical significance (P < 0.05) was observed at all visits except month 12 for routine patients. The diabetes patients also demonstrated the same giant cell difference, and the statistical significance was observed at all visits including month 12. A similar trend was also observed in the glaucoma patients, with statistical significance only at the 3-month visit. For cell deposits, significant differences in favor of the HSM lens (P < 0.05) were observed at 3 months among routine and diabetes patients, and at 3 and 6 months among glaucoma patients. A longitudinal data analysis using the generalized estimating equation approach indicated statistically significant treatment effect of HSM lenses in reducing inflammation in all patients except for cellular deposits in diabetes patients. In all patient groups, sight-threatening complications were not reported either more frequently or with more severity than normally expected for patients who have undergone cataract extraction and IOL implantation. CONCLUSIONS: The present study, the only one to have used phacoemulsification in virtually all patients (211/220 [96%] routine, 57/58 [98%] glaucoma, and 84/89 [94%] diabetes) is the largest to evaluate and compare concurrently routine, glaucoma, and diabetes patients. It is also the first US patient population study to document that heparin surface modification reduces postoperative inflammatory responses, as measured by specular micrography and slit-lamp examination, especially in the early postoperative period.

Aged↗

[Treatment of chronic Wilson's disease in 2 patients using plasmapheresis--clinico-biochemical observations].

INTRODUCTION: The introduction of penicillamine in the treatment of Wilson's disease (hepatolenticular degeneration) was a historical event [1]. D-pericillamine (d-PAM) showed some potential side effects such as myasthenia, kidney toxicity, etc. In previous decade the treatment of Wilson's disease (WD) with zinc sulphate started successfully [4]. Danks [7] described the use of exchanged transfusions, peritoneal dialysis and plasmapheresis in the treatment of young patients with WD in acute liver failure. These patients had acute copper poisoning. The results of this study were beneficial. MATERIAL AND METHODS: Therapeutic plasmapheresis (PF) has been used in many diseases in which immunological mechanisms are proved [8, 9]. We started with using PF in the treatment of two young chronic patients with Wilson's disease. The clinical picture of patients became worse, probably due to the decrease in cupriuretic effect of d-PAM. One patient (1) did not take d-PAM regularly. In this study PF was performed with the use of haemonetics V-50 and filter 704. During the treatment with PF, 2000 ml of plasma was always exchanged, i.e. removed. During the treatment with PF the patients were hospitalized at the Department of Neurology and Psychiatry of Children and Young People. CASE REPORT AND RESULTS: Patient No. 1. A 24-year-old man, born in 1965, came with a coarse tremor. He has been diagnosed as WD at the age of 18. Kayser-Fleischer rings were found in the cornea by slit-lamp examination. The disease began when he was 15 years old with polymorphous difficulties. In time tremor became more severe. It was apparent when the patient made any movement. The first treatment with PF (1) lasted from February 13 to March 16, 1989. The patient had 10 PF without any side effect. During the treatment with PF the patient felt better. After PF-tremor was reduced significantly, and subjective and objective condition ameliorated. The patient (1) was readmitted to the hospital on June 24, 1991 for continuation of the treatment with PF. Anamnestic data and neurological examination revealed progression of the disease. His condition became worse, especially tremor. He could not write a single letter (Figures 1-5) and walk without help of the others. His tremor became the severest when he made any kind of voluntary movement. The second treatment with PF started on June 25, 1991 and finished on July 16, 1991. He received 9 PF in this series. The treatment was without side effects. Tremor was reduced approximately by 15%. Plasma copper examined before and after 9 PF showed different values (Table 2). This difference (2.79 mumol/l; 23.70%) in plasma copper level was removed from circulation. Patient No. 2. A 23-year-old man, born in 1966, came to the hospital with acute exacerbation of WD. At the age of 16 latent psychosis was diagnosed. One year later diagnosis of WD was established in the hospital when he was 17 years old. Kayser-Fleischer rings were found in the cornea by slit-lamp examination. The treatment with d-PAM and other drugs (BAL, symptomatic therapies, sedatives, antidepressants, etc.) has been accompanied with good and long-term remissions and short exacerbation. A few years later exacerbation became longer and longer and worse and worse. He was admitted to the hospital on November 28, 1989 with acute relapse of WD. His condition was very difficult, completely bedridden. The treatment with PF started on December 26, 1989 and lasted to January 25, 1990. The treatment with PF was without d-PAM. He was only given symptomatic therapies. After a few PF he demonstrated side effects with nausea, sometimes vomiting, face sweating, pulse rate of about 120/min while blood pressure was normal. Therefore he was given human albumin in the next day, and no side effects were observed. The removal of little plasma copper from blood circulation correlated well with a small improvement in clinical symtpomatology. The rigidity was reduced and voluntary movements bec

Adult↗

[Standardized semiquantitative analysis of corneal neovascularization using projected corneal photographs--pilot study after perforating corneal keratoplasty before immune reaction].

BACKGROUND: A semiquantitative scheme for analysis of corneal neovascularization using projected corneal photographs is demonstrated and tested in a pilot study to analyze occurrence of corneal neovascularization in patients after perforating keratoplasty which subsequently developed transplant rejection. METHODS: Corneal photographs on the slit lamp with diffuse frontal illumination were obtained in a standardized technique. Slides were projected with 100 x magnification and analyzed twice with a 2 months interval. Corneal vessels were graded by two independent observers in each of 12 corneal sectors in a standardized fashion (grade 0: no vessels beyond limbus, 1: vessels between limbus and outer end of a double-running diagonal suture; 2: vessels between outer suture end and graft-host junction; 3: vessels reaching graft-host junction; 4: vessels within donor cornea). All patients with endothelial graft rejection of the prospective Erlangen non-high-risk keratoplasty study were included in a pilot study (1/1997-6/2000: 13 of 325; 4%). One patient without photographs available was excluded. Corneal photographs taken prior to surgery (n = 10), at the last 3 monthly-routine control before (10), at rejection episode (12) and one year later (10) were evaluated for corneal neovascularization. RESULTS: Interobserver correlation at the two assessments was 0.79 and 0.86 (Kendall's Tau B). Correlation between the assessments at the two analyses 2 months apart was 0.8. New vessels with diameter up to 6 microns can be detected. 8 of 12 analyzed patients (67%) with immune reaction after keratoplasty developed corneal neovascularization within 1 year after operation prior to transplant rejection in at least one corneal sector (2.1 +/- 1.9 sectors; 1-6). At time of rejection, new vessels reached the graft-host junction in 2 patients, in 1 patient vessels grew into the donor cornea, whereas in 8 the vessels were seen beyond the outer suture end without reaching host-graft junction (grade I: 1 patient). New vessels usually pointed to the outer suture ends of the double-running suture. CONCLUSIONS: Development of corneal neovascularization e.g. after keratoplasty can be assessed reliably using projected slides of corneal photographs at 100 x magnification. This method has the advantage of being more objective, precise and available compared to simple evaluation at the slit lamp. Postkeratoplasty corneal neovascularization seems to be common in non-high-risk eyes later developing transplant rejection. However, new vessels usually do not reach the host-graft junction. Whether neovascularization after keratoplasty demonstrates a risk factor for subsequent transplant rejection remains to be analyzed in a greater study.

Cornea↗

[Biomorphometry of corneal epithelium with slit lamp-adapted optical coherence tomography].

INTRODUCTION: The purpose of this study was to evaluate the biomorphometry of the corneal epithelium with slitlamp-adapted optical coherence tomography (OCT). PATIENTS AND METHODS: In a clinical study, slitlamp-adapted OCT of the cornea was performed in 15 patients before and immediately after therapeutic corneal abrasion. Central corneal epithelium thickness measurements were compared to the pre- and postoperative central corneal thickness. RESULTS: Preoperatively, the corneal epithelium could be visualised from the highest OCT light reflections at the interfaces air-tear film and epithelium-Bowman's membrane. The preoperative mean geometrical central epithelial thickness determined with OCT ranged from 65 +/- 12 microns to 72 +/- 14 microns (45-92 microns). The mean difference of the pre- and postoperative central corneal thickness was 48 +/- 19 microns (9-79 microns). This resulted in a deviation from the direct epithelial thickness measurements of 26-33%. The reproducibility of the geometrical epithelial thickness was +/- 9 microns. CONCLUSIONS: Slitlamp-adapted OCT enabled a noncontact evaluation of the corneal epithelium. The difference between direct and indirect corneal epithelium thickness measurements could be related to the partial optical inclusion of the precorneal tear film and the Bowman's membrane. With some restrictions the biomorphometry of the corneal epithelium with slitlamp-adapted OCT seems to be a valuable technique to monitor therapeutical and refractive procedures of the cornea.

Adult↗

Reproducibility of measurements with a new slit lamp-mounted ocular blood flow tonograph.

PURPOSE: To assess the reliability of measurements of intraocular pressure (i.o.p.), pulse amplitude (PA), and pulsatile ocular blood flow (POBF) and the validity of measurements of IOP with a new ocular blood flow tonograph. METHODS: Intraocular pressure pulse was assessed with pneumatic tonometry. In this study, we used the OBF Labs ocular blood flow tonograph with two different pneumatic probes, a modified Langham probe and a newly developed probe. One ophthalmologist compared two machines, first with the modified Langham probe and secondly with the newly developed probe (40 volunteers). Additionally, two ophthalmologists performed measurements on different days and in different sequence (34 volunteers). Furthermore, results of IOP measurements performed with this tonograph were compared to those of Goldmann applanation tonometry (213 volunteers). RESULTS: Using the modified Langham probe, POBF and PA were associated with the machine used for the test. However, using the newly developed pobe, no relevant or statistically significant differences were found for any variables, and reliability coefficients were between 0.70 and 0.90. Linear regression analysis of the Goldmann applanation tonometer on the measurements of IOP with the tonograph showed a regression coefficient of 0.765. CONCLUSIONS: Results of measurements performed with this ocular blood flow tonograph and the newly developed probe are expected to be reliable and comparable.

Adolescent↗

Comparison of two techniques of marking the horizontal axis during excimer laser keratorefractive surgery for myopic astigmatism.

PURPOSE: To compare two methods of limbal marking used during laser refractive surgery for myopic astigmatism. DESIGN: Retrospective chart review. METHODS: Forty-two eyes of 42 patients who underwent photorefractive keratectomy (PRK) or laser-assisted in-situ keratomileusis (LASIK) for myopic astigmatism were marked preoperatively to identify the horizontal axis. In 18 eyes, marks were placed at the slit lamp (SL) with the slit beam set at 180 degrees as a reference. In 24 eyes, marks were placed in the laser room (LR) immediately before reclining under the laser. All treatments were performed with the Alcon LADARVision excimer laser system. Vector analysis of postoperative cylinder and reduction in cylinder and uncorrected and best-corrected visual acuity were evaluated for both groups. RESULTS: The mean postoperative magnitude of error was -0.19 +/- 0.44 diopters for the LR group and -0.09 +/- 0.42 diopters for the SL group (P = .439, NS). Both groups had a mean angle of error indicating an overall counterclockwise rotation of axis with an angle of error of 6.3 +/- 8.7 degrees for the LR group and 8.0 +/- 10.2 degrees for the SL group (P = .562, NS). CONCLUSIONS: We found no significant difference in outcomes with an overall trend toward undercorrection of cylinder in both groups, leaving room for improvement after refractive surgery for myopic astigmatism.

Astigmatism↗

Imaging posterior polymorphous corneal dystrophy by in vivo confocal microscopy.

To identify features of posterior polymorphous dystrophy (PPMD) by in vivo confocal microscopy, the corneas of a female patient with PPMD were exam ned using slit-lamp biomicroscopy and slit-scanning in vivo confocal microscopy. Characteristic endothelial vesicular and band lesions were seen clinically and easily identified using in vivo confocal microscopy. However endothelial pleomorphism, an increased density and reflectance of posterior stromal keratocytes, and prominence of corneal nerves were also delineated. In vivo confocal microscopy enhances clinicopathological diagnosis and follow up of corneal dystrophies with subtle clinical presentations, such as PPMD.

Corneal Dystrophies, Hereditary↗

In vivo confocal microscopy of posterior polymorphous dystrophy.

PURPOSE: This study was designed to delineate the morphologic features of posterior polymorphous dystrophy (PPD) using in vivo confocal microscopy. METHODS: Six patients with clinically diagnosed PPD were examined by slit-lamp biomicroscopy, Orbscan II slit-scanning elevation topography, and in vivo confocal microscopy. RESULTS: Endothelial cell densities ranged from 613 to 3,405 cells/mm and endothelial polymegathism was noted in all cases, whereas endothelial pleomorphism was not a prominent feature. Three cases exhibited bright endothelial nuclei. A variety of abnormal curvilinear and vesicular abnormalities were imaged by in vivo confocal microscopy, with lesions ranging between 6 and 159 microm in diameter. Abnormal endothelial cells were visible within some of these lesions. Six cases showed hyperreflectivity at the level of Descemet's membrane around the lesions. Deep stromal keratocytes appeared to aggregate around, or were compressed by, the endothelial lesions in one case. CONCLUSIONS: We report the largest case series of PPD imaged by in vivo confocal microscopy. The ability of in vivo confocal microscopy to assess the living cornea over time enables monitoring of disease progression and thus the potential to identify and correlate development of, or changes in, microstructural features. As more data become available, these analyses may enable the formulation of prognostic and diagnostic criteria.

Adult↗

Semiquantitative interference study of fatty layer of precorneal film.

Reflecting colours from the fatty layer of the precorneal film have been studied using mat filter (grease-proof paper, parchment paper, tracing paper) in front of the slit lamp mirror, maximally open light slit in a half-lit room, and magnification x 15. The palpebral fissure was narrowed until occurrence of red interference colour (2000 A). In 206 normal eyes the fatty layer was 102 +/- 3nm (+/- SEM), or about 0.1 micron, independent of age, sex and BUT (break up time). Maximum on awakening. Coefficient of variation 12.7 per cent. An increased fatty layer was noticed in cases of blepharitis (129 +/- 8 nm), in 91 per cent wearing hard contact lenses and 73 per cent wearing soft contact lenses. The fatty layer was likewise seen to be augmented in patients with acute infectious conjunctivitis (193 +/- 3 nm), chronic infectious conjunctivitis (164 +/- 7 nm), and in all states complicated by bacterial infection. The fatty layer is normal in allergic and chronic simple conjunctivitis. Silicone oil was found to effect reduction of the fatty layer.

Adipose Tissue↗

Mapping the corneal sub-basal nerve plexus in keratoconus by in vivo laser scanning confocal microscopy.

PURPOSE: To produce a two-dimensional reconstruction map of the living corneal sub-basal nerve plexus in keratoconus with in vivo confocal microscopy. METHODS: Four eyes of four subjects with keratoconus were examined by slit lamp biomicroscopy, Orbscan II slit-scanning elevation topography (Bausch & Lomb Surgical, Rochester, NY), and laser scanning in vivo confocal microscopy with the Heidelberg Retina Tomograph II, Rostock Corneal Module (Heidelberg Engineering, Heidelberg, Germany). Subjects were asked to fixate on targets arranged in a grid to enable in vivo confocal microscopy of the cornea in a wide range of positions. RESULTS: A mean of 402 +/- 57 images were obtained for each cornea, to create confluent montages. The mean dimensions of the corneal areas mapped were 6.60 +/- 0.70 mm horizontally and 5.91 +/- 0.72 mm vertically. All corneas exhibited abnormal sub-basal nerve architecture compared with patterns previously observed in normal corneas. At the apex of the cone, a tortuous network of nerve fiber bundles was noted, many of which formed closed loops. At the topographic base of the cone, nerve fiber bundles appeared to follow the contour of the base, with many of the bundles running concentrically in this region. Central sub-basal nerve density was significantly lower in keratoconus corneas (10,478 +/- 2,188 microm/mm2) compared with normal corneas (21,668 +/- 1,411 microm/mm2; Mann-Whitney; P < 0.01). CONCLUSIONS: This is the first study to elucidate the overall distribution of sub-basal nerves in the living central to midperipheral human cornea in keratoconus, using laser scanning in vivo confocal microscopy.

Adult↗

Evaluation of photographic methods for documentation of lens opacities.

Several systems have been developed to document lens opacities photographically. In general, the settings for these photographs have been standardized, but there has been no scientific basis for the selection of these settings. We investigated several of these variables. We examined the effect of degree of angulation of the slit beam in slit photography of the nucleus and found no difference in the grading of nuclear opacities in paired photographs taken with illumination angles of 30 or 40 degrees. Similarly, we found no difference between black-and-white and color film in the detection or grading of either cortical or posterior subcapsular opacities in retroillumination photographs and no difference if a Neitz or an Oxford cataract camera was used. In view of the equivalence of these methods, we would advocate, for reasons of ease of application and cost, the use of a single-color slit-lamp photograph with a 30 degree slit angle for documenting nuclear opacities, and the use of black-and-white retroillumination photography with either the Neitz or Oxford cataract cameras for cortical and posterior subcapsular opacities.

Adult↗

Effect of pilocarpine on anterior chamber angles.

Pilocarpine is widely used in the treatment of glaucoma, especially for the acute form of angle-closure glaucoma. Previous studies have shown that pilocarpine decreases central anterior chamber depth. In the present study, a quantitative measurement method, applying Scheimpflug photography, was used to report whether pilocarpine also affected the anterior chamber angles. Twenty-nine normal Chinese subjects, 17 female and 12 male with an age range from 11 to 63 years old, were enrolled. One eye of each subject was treated with one drop of 2% pilocarpine. Photographs of each of four quadrants were taken prior to, and after, pilocarpine treatment in both eyes, using a rotating slit-lamp video camera based on the Scheimpflug principle. The slit beams were set at 0 degrees and 90 degrees. The eyes which did not receive pilocarpine treatment served as control. The angles of the four quadrants were calculated for both eyes both prior to, and after, pilocarpine treatment, and results were compared by Student's paired t-test. The comparison of angles between the eyes prior to, and after, pilocarpine treatment indicated that there is a significant narrowing of angles in all quadrants. The complex factors involved in the change of anterior chamber angle are reviewed in the light of muscarinic action of pilocarpine.

Adolescent↗

Usefulness of Scheimpflug photography to follow up Wilson's disease.

A 24-year old female with ocular changes (Kayser-Fleischer ring and sunflower cataract) indicating Wilson's disease was followed up from 9 years of age with anterior eye segment image documentation by Scheimpflug photography. A low copper diet and systemic D-penicillamine were administered after the initial diagnosis of Wilson's disease. During a 15-year follow-up period, the yellowish/brown-colored granular opacification on the anterior lens capsule and/or in the capsule has mostly disappeared and instead, the same type of opacification has emerged on the posterior lens capsule, showing rather progressive changes compared with the initial findings. These changes which had developed in the lens during the past 15 years were difficult to detect by slit lamp examination alone, but they were clearly revealed by Scheimpflug slit images. To our knowledge this is the first case report on ocular changes disclosed through the application of a newly developed anterior eye segment examination. Ergo, Scheimpflug photography is valuable for follow-up studies of ocular complications seen in patients with Wilson's disease.

Adult↗

Anterior chamber depth measurement using the split-lamp microscope.

I devised a new and simple method to measure the anterior chamber depth that requires only a Haag-Streit 900 slit lamp. Viewing the anterior chamber at 45 degrees and matching the height of the corneal slit beam to the depth of the anterior chamber enables the observer to calculate the anterior chamber depth by multiplying the measured slit height by 1.4 or, more accurately, by use of the table provided. The accuracy over the range of clinically encountered depths of the anterior changer is +/- 0.2 mm relative to standard pachometry.

Anterior Chamber↗

Confocal microscopy of the cornea.

This paper provides the clinician and the researcher with an in-depth manual on the use of a scanning-slit confocal light microscope for the clinical examination and investigation of the living human cornea in vivo. The scope of the paper includes a thorough explanation of the principles of various types of confocal microscopes as well as their limitations, a comprehensive review of the development of biomicroscopy of the eye, and a comparison of confocal microscopy and other optical techniques such as optical coherence tomography. The early work of Ridley, Goldmann and others on point illumination in early confocal instruments is described. The main part of the paper describes and illustrates the clinical examination of the living human cornea with the confocal microscope. Figures (many in color) from the normal cornea, the cornea with known parthologies, and the postsurgical cornea are selected for their educational value. Photographs of standard light microscopy of fixed, human corneal sections are compared with confocal maicroscopic images. Where appropriate, slit lamp color photographs are compared with confocal microscopic images. The clinical scanning-slit confocal microscope is an evolving instrument for biomicroscopy of the living eye.

Animals↗