Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SILICONES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Changes in the activities of various lipid and carbohydrate biosynthetic enzymes in the diatom Cyclotella cryptica in response to silicon deficiency.

The effects of silicon deficiency on the activities of several enzymes involved in lipid and storage carbohydrate synthesis in the diatom Cyclotella cryptica were determined. The activity of UDPglucose pyrophosphorylase was not affected after 4 h of silicon-deficient growth, but the activity of UDPglucose: beta-(1----3)-glucan-beta-3-glucosyltransferase (chrysolaminarin synthase) was reduced by 31% during this period. Acetyl-CoA synthetase, acetyl-CoA hydrolase, and citrate synthase activities were present in cell-free extracts of C. cryptica, but did not change in response to 4 h of silicon deficiency. However, the activity of acetyl-CoA carboxylase increased approximately two- and fourfold after 4 and 15 h of silicon-deficient growth, respectively. This induction could be blocked by cycloheximide (20 micrograms/ml) and actinomycin D (10 micrograms/ml), suggesting that silicon deficiency may induce an increase in the rate of acetyl-CoA carboxylase synthesis. These changes in enzymatic activity may be partially responsible for the accumulation of lipids that has been observed in C. cryptica and other diatoms in response to silicon deficiency.

Acetate-CoA Ligase↗

Nerve regeneration through holey silicone tubes.

Recent studies focus on regeneration where nerve stumps are placed in a silicone tube. Since the tube is impermeable, the fluid and cells that collect from the stumps bath the axons. This is presumably beneficial. Making the tube permeable by making holes in its walls should change the patterns of regeneration. If this is done, the major cytologic change is an increase in the fascicular perineurium. There are more individual fascicles, more cells line each fascicle and the lining cells are coated by more prominent external laminae than after similar regeneration in a regular silicone tube or in the normal untransected nerve. For axonal numbers, there are more myelinated and unmyelinated axons in the gap and more unmyelinated axons in the distal stump than after regeneration in a regular silicone tube. The numbers in the holey tube regenerate are statistically different from normal but they are closer to normal than after similar regeneration in a regular silicone tube. There are significantly fewer myelinated and unmyelinated axons than in the normal sural nerve after regeneration through a holey tube, but there are more than after regeneration through a regular tube. The numbers of axons in the nerve to the medial gastrocnemius muscle are not significantly different from normal or from the other regeneration paradigms. These data allow the suggestion that regeneration through a silicone tube with macroscopic holes in its walls may be superior in certain respects to regeneration through a regular impermeable silicone tube.

Animals↗

Treatment of scars and keloids with a cream containing silicone oil.

The clinical effect of silicone cream containing 20% of silicone oil was tested on 47 patients with hypertrophic scars and keloids. A silicone cream/occlusive dressing technique, quite similar in manner to silicone gel treatment, resulted in a remarkable improvement of scars and keloids in 9 of 11 cases (82%) whereas the simple application of the cream onto the scars and keloids of 36 cases resulted in only mild improvement in 8 (22%). Using the chi-square test, a statistically significant difference was seen between these two treatments (p less than 0.01). From these findings, we suggest that occlusion and hydration are the principal modes of action of the silicone gel sheet method and our silicone cream/occlusive dressing technique.

Adolescent↗

Light-weight RTV silicone for maxillofacial prostheses.

Weight is a problem in retention of large skin-textured maxillofacial prostheses. The purpose of this investigation was to test the feasibility of mixing foam RTV silicone rubber with conventional RTV silicone rubber to obtain a light-weight material. Various mixtures of foam and conventional silicone rubber were formulated and tested for strength, accuracy of molding, color application, color stability, and texture. A special flask to support the mold was necessary in order to overcome expansion problems associated with gas formation of the foam silicone rubber. The mold required venting to release the gas and to reduce the expansion of the prosthesis in order to maintain accuracy. Molding, accuracy, texture, and color problems were overcome. Reduction of weight proportionate to reduction of tear strength of the material formulated, however, did not allow routine use of mixtures of foam and conventional silicone. When the weight of a prosthesis is critical and excessive and thickness is sufficient to give adequate strength, the foam and conventional silicone mixture can be used.

Color↗

Wettability of a hydrophilic addition silicone impression material.

Silicone impression materials, long noted for their poor wettability, have typically demonstrated contact angles with water greater than 90 degrees. This study compared the wettability of a new hydrophilic addition silicone with that of other impression materials. Specimens from various viscosities of polyether, polysulfide, hydrophobic addition silicone, and hydrophilic addition silicone were formed against a smooth surface. The advancing contact angle of a saturated aqueous solution of CaSO4 on the impression materials was measured after 1 minute. Mean contact angles were calculated and results were analyzed by ANOVA and a multiple comparison of means procedure. Differences between pairs of contact angle means were found to be statistically significant except for the polyether-hydrophilic addition silicone pair. The wettability of the hydrophilic addition silicone impression material was found to be not significantly different from that of a polyether impression material.

Calcium Sulfate↗

Accuracy, detail reproduction, and hardness of gypsum casts produced from silicone impressions treated with glow discharge.

Plasma treatment has been reported to improve the wettability of silicone impression materials. This study investigated whether plasma treatment of silicone impressions influenced the linear dimensional accuracy, detail reproducibility, and surface hardness of models produced from a type IV dental die stone. Five silicone impressions materials were used in this study. Linear dimensional accuracy and detail reproduction were tested according to ISO standards. Surface hardness was evaluated with a Vickers hardness test. The results indicated that plasma-treated impressions from Xantopren and Provil silicone impression materials had significantly smaller dimensional change than their respective controls, and the other materials were not influenced. The detail reproduction was superior in casts produced from plasma-treated impressions from President silicone. Surface hardness was not influenced by the treatment. Plasma treatment of silicone impressions has no negative influence on the tested physical properties of die stone models.

Analysis of Variance↗

Evidence that Müller cells can phagocytize egg-lecithin-coated silicone particles.

This study is designed to better understand the function of the Müller cells of the retina through the use of silicon particles that had been injected into the vitreous body of the eye and via an analysis of the number of gap junctions associated with these cells. Following intraocular injection of a silicone oil mixture into the rabbit retina, numerous small silicone particles less than 1 micron in diameter were found attached to the basement membrane of the inner limiting membrane, subjacent to the Müller cells. On the sites to which the silicone particles attached, the basement membrane was reduced in thickness or completely disappeared. The 'end-feet' of the cell membrane facing the silicone particles became concave appearing as if they were in the process of incorporating the particles into the cell. Similarly, the Müller cells occasionally extended cytoplasmic processes through the basement membrane and towards the silicone particles, as if to engulf them. Gap junctions were observed but only in association with the Müller cells. They were often found between the 'end-feet' of adjacent Müller cells or the 'end-feet' of one cell and very thin cytoplasmic process of a neighboring cell. On rare occasions, they were located between 'end-feet' of the same Müller cell. The percentage of 'end-feet' displaying gap junctions was 38 +/- 8% (mean +/- SE). These data suggest that the Müller cells are important in the maintenance of normal retinal function by their ability to phagocytize foreign substances and by their ability to transmit information to various parts of the retina through cell-to-cell connections established by gap junctions.

Animals↗

Silicone as a trace contaminant in laboratory solvents.

This paper examines a suite of lipid solvents for their utility as solvents for silicone analysis by Raman spectroscopy, and discusses the observation that off-the-shelf reagents could be contaminated by silicone during manufacture. Of the solvents examined, only chloroform was transparent in those spectral regions (chiefly 500 cm-1) in which silicone exhibits its Raman spectrum. Also, the chloroform examined showed evidence of silicone contamination. Therefore, chloroform is suggested as a suitable solvent for Raman spectroscopic work involving silicone, if one is careful to confirm that the chosen chloroform is not contaminated by silicone.

Drug Contamination↗

A pathophysiological examination of the biophysics and bioreactivity of silicone breast implants.

Historically, silicones have been considered biologically inert materials, and have therefore been used widely in a variety of medical applications. Recently, controversy has arisen concerning the bioreactivity of silicone; reports of adverse inflammatory and immunological complications that may be evoked by silicone breast implants have appeared in the medical literature and have received great attention from the lay press. The phenomena said to be associated with silicones may be attributed pathophysiologically to the inherent surface activity of silicone. The human body's initial response to the silicone of breast implants is the adsorption of various plasma proteins, including clotting and complement proteins, to the implant surface. Other macromolecules in the biological milieu may follow. The conformational integrity of this adsorbed macromolecular layer affects much of the subsequent biological reaction. Clinically silent inflammation, locally significant inflammation, inflammation with constitutional symptoms, and inflammation with immunological activation are possible consequences.

Adsorption↗

Epidemiology of silicone-related disease.

The epidemiology of silicone-related disease (SRD) is complicated by the variety of disease endpoints that have been associated with silicone exposure and the atypical nature of these diseases in silicone-exposed women. Current research reviewed here suggests that SRD may constitute a new disease entity, thus complicating disease definition and rendering studies of classic disease unlikely to detect risks of silicone exposure. This report addresses the most important study design issues (disease and exposure definitions, bias, confounding, and power) in the context of studies of SRD. The variety of silicones used complicates the definition of exposure for all studies, and for some populations simply determining who was implanted will be difficult. For any of these studies, inadequate patient follow-up is likely to underestimate disease risk. Studies of SRD are also complicated by confounding. That is, whether or not a woman chooses to receive an implant is related to her age, race, and other variables also related to rheumatoid and autoimmune disease. The absence of an appropriate control group also plaques published studies of silicone-related disease. Finally, inadequate sample size, resulting in studies of low statistical power, is a critical problem for rare diseases such as SRD. These points are illustrated using two published studies and five studies in progress.

Breast Implants↗

Use of silicone fluids in studies of cellular amino acids.

In numerous cellular studies, cells labeled with radioisotopes have been separated from the labeling medium by an aqueous solution in order to determine the quantity of internalized labels; however, the aqueous wash tends to remove significant labeling from the cells. Therefore, in order to preserve all of the internalized labels, non-aqueous medium such as silicone fluids may be used. The termination of the labeling is achieved in the silicone method when, upon centrifugation, the cells separate from the medium and enter the silicone fluid to sediment to the tube bottom. This sedimentation of cells placed above a layer of silicone fluid exhibits a critical dependence on the centrifugal force, and gives rise to an uncertainty of only 2 s in determining the time of separation of cells from the medium using General Electric F-50 silicone fluid and a modified Beckman J2-21 centrifuge. It is therefore possible to determine the kinetics of incorporation of labeled amino acids into intracellular pools and proteins. In particular, since this silicone wash method determines the size of the total pool and the aqueous wash method determines the size of the acid-extractable pool, the simultaneous measurements of the size of both pools leads to the determination of the kinetics of labeling of the free amino acid pool. Among many possible applications and extensions of these methods, the studies of formation of intracellular pools and relations among different pools of transported molecules, such as water and amino acids, appear promising.

Amino Acids↗

Silicone synovitis. A perspective.

Silicone implant arthroplasty is, arguably, the most effective treatment for the majority of patients with symptomatic arthritis in the hand and wrist. In 1985 the problem of silicone synovitis was first brought to our attention. Since that time there have been numerous reports on this condition leading to a worldwide trend against the use of silicone implants. However, the true incidence and effects of silicone synovitis have not been clearly defined. For this reason, we have undertaken a survey of all patients who have undergone silicone implant arthroplasty in the wrist and hand in our Unit between 1975 and 1990. Patients with rheumatoid arthritis and those undergoing MP or IP joint arthroplasty were excluded. Of the 289 implant arthroplasties remaining, we have been able to review personally 229 implants with a mean follow-up of 3.8 years (range 1-15). Although 40% of cases showed significant radiological changes, only 11 patients (4.8%) developed symptoms requiring treatment. Of these, two were managed conservatively whilst the rest underwent revision surgery, all with entirely satisfactory results. We conclude that silicone implant arthroplasty remains the treatment of choice for patients with painful joint disease in the hand and wrist.

Adolescent↗

Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic intraocular lenses with 6-mm optics in an intraindividual comparison.

PURPOSE: Intraindividual comparison of tilt and decentration of three-piece foldable intraocular lenses (IOLs) with 6-mm optics and different edge design and material. DESIGN: Prospective randomized study. METHODS: Twenty-five patients with senile cataract (group I) received a foldable silicone, sharp optic edge IOL in one eye and a silicone, rounded optic edge IOL in the other eye. Group II (n = 28) received the foldable silicone, sharp optic edge IOL in one eye and an acrylate, sharp optic edge IOL in the other eye. Scheimpflug photography was performed after the procedure with an anterior eye segment analysis system. Tilt and decentration of the IOL optic were measured 1 week, 6 months, and 12 months after the procedure. RESULTS: In group I, the foldable silicone, sharp optic edge IOL showed a mean optic tilt of 3.03 +/- 1.79 degrees and an optic decentration of 0.24 +/- 0.13 mm; the silicone, rounded optic edge IOL showed a tilt of 3.26 +/- 1.69 degrees and a decentration of 0.23 +/- 0.13 mm. In group II, the foldable silicone, sharp optic edge IOL showed an average tilt of 2.34 +/- 1.81 degrees and a decentration of 0.29 +/- 0.21 mm after 12 months; the acrylate, sharp optic edge IOL had a tilt of 2.32 +/- 1.41 degrees and a decentration of 0.24 +/- 0.10 mm. There were no significant differences in either group. CONCLUSION: The examined IOLs showed a stable position regarding tilt and decentration in the first 12 postoperative months, independent of material and edge design. Slight deviations from the optical axis might affect the outcome in aspheric or multifocal IOLs.

Acrylic Resins↗

Hydrogen plasma surface activation of silicon for biomedical applications.

Silicon has gradually been recognized to be an essential trace element in the normal metabolism of higher animals, and the role of silicon in the human body has aroused interests in the biomedical community. In fact, the interactions between silicon-based devices and the human body such as biosensors and microelectromechanical systems (MEMS) often suffer from poor biocompatibility. In this work, hydrogen plasma immersion ion implantation (H-PIII) is conducted to improve the bioactivity or bone conductivity of silicon. In order to investigate the formation mechanism of bone-like apatite on the surface of the hydrogen implanted silicon wafer, two comparative experiments, hydrogenation and argon bombardment, are performed. The H-PIII sample exhibits an amorphous surface consisting of Si-H bonds. After immersion in simulated body fluids, a negatively charged surface containing the functional group ([triple bond]Si-O-) is produced and bone-like apatite is observed to nucleate and grow on the surface. The surface of the H-PIII silicon wafer favors the adhesion and growth of osteoblast cells and good cytocompatibility may be inferred.

Biomedical Engineering↗

Optical properties of porphyrin molecules immobilized in nano-porous silicon.

The paper aims at studying optical properties of porous silicon powders and thin films which were impregnated with different porphyrin molecules. It has been shown that introducing porphyrins into porous silicon matrix results in quenching of luminescence from porous silicon, while luminescence of porphyrins survives, though its structure changes. At the same time, porphyrins in porous silicon matrix which was preliminarily oxidized does not alter luminescence from porphyrins. Generation of singlet oxygen by illuminated porphyrin/porous silicon composite is confirmed by additional oxidation of porous silicon and by the observation of characteristic 1270 nm luminescence band.

Adsorption↗

Highly active, lipase silicone elastomers.

Lipase Candida rugosa was entrapped in silicone rubber via condensation-cure room temperature vulcanization of silanol-terminated poly(dimethylsiloxane) with tetraethyl orthosilicate as a crosslinker, to give a highly active silicone-enzyme elastomer. The effect on enzyme activity of addition of water and hydrophilic polymeric moieties based on poly(ethylene oxide) 2 was examined, as were crosslinker concentration, enzyme concentration, and elastomer thickness. It was demonstrated that lipase is most active in silicone elastomers and more active in silicone oils than simple hydrocarbons. Crosslink density in these elastomers was not an important factor in the reactivity of the rubber. However, the addition of hydrophilic species prior to elastomer formation decreased the efficiency both of the dispersion of the enzyme and the resulting activity of the elastomer. This effect could be moderated by prior exposure of the lipase to silicone oil. Thus, hydrophobic silicones play a protective/activating role for lipase.

Biocompatible Materials↗

Effect of surface proteins on Staphylococcus epidermidis adhesion and colonization on silicone.

Shunt infections are one of the most serious complications in shunt implant surgery. Previous studies have suggested that cerebrospinal fluid (CSF) proteins could affect bacterial adhesion and subsequent shunt infection. A systematic study using immobilized protein on the surface of silane-modified silicone was conducted to determine how these modifications influenced Staphylococcus epidermidis adhesion and colonization. A comparison was also made with silicone having physically adsorbed protein. A colony-counting adhesion assay and scanning electron microscopy (SEM) were used to provide quantitative analysis of bacterial adhesion and semi-quantitative analysis of bacterial colonization, respectively. In order to determine the appropriate silanization process for effective protein immobilization, the effect of bovine serum albumin (BSA) immobilized on n-3-(trimethoxysilyl)propyl-ethylenediamine (AEAPS)/silicone, aminopropyltriethoxysilane (APTMS)/silicone, 3-(glycidyloxypropyl)trimethoxysilane (GPTMS)/silicone, and octadecyltrichlorosilane (OTS)/silicone on bacterial adhesion was investigated. Upon identifying that OTS is the most effective silane, different types of proteins, including: BSA, human serum albumin (HSA), gamma-globulin, and fibrinogen were immobilized on OTS/silicone by a photo-immobilization method. Immobilized protein on modified silicone surfaces was found to be stable in saline for 30 days, while physically adsorbed protein showed instability within hours as determined by contact angle measurements and X-ray photoelectron spectroscopy (XPS). For HSA/OTS/silicone, BSA/OTS/silicone, gamma-globulin/OTS/silicone, fibrinogen/OTS/silicon, and physically absorbed BSA on silicone, the contact angles were 78.5 degrees, 80.7 degrees, 78.9 degrees, 81.3 degrees, and 96.5 degrees; and the amount of nitrogen content was found to be 4.6%, 5.0%, 5.6%, 7.2%, and 3.2%, respectively. All protein immobilized on OTS/silicone surfaces significantly reduced bacterial adhesion by around 75% compared to untreated silicone, while physically adsorbed BSA on silicone reduced by only 29.4%, as determined by colony-counting adhesion assay. However, there was no significant difference on bacterial adhesion among the different types of proteins immobilized on OTS/silicone. Minimizing bacterial adhesion and colonization can be attributed to the increased concentration of -NH2 group, and stability and more hydrophilic nature of the protein/OTS/silicone surfaces.

Animals↗

Effect of surface charge and hydrophobicity of polyurethanes and silicone rubbers on L929 cells response.

Wettability and zeta potential studies were performed to characterize the hydrophobicity and surface charge of virgin and oxygen plasma irradiated silicone rubbers and polyurethane (polyether and polyesther) samples and evaluate the effect of hydrophobicity and surface charge on fibroblast cells attachment and growth. The surface properties of polyurethanes and silicones and plasma irradiated surfaces were compared by water drop contact angle and zeta potential measurement. Using SEM photomicrographs to study the morphology of virgin and plasma irradiated samples surfaces and light microscopy for study the behavior of cell attachment on these surfaces. Water drop contact angle measurements show that in despite of the silicones, the polyurethanes become more hydrophobic and have stable surface than silicones. Results show that wettability of plasma treated silicones increase and after 48 h recovery take place. Zeta potential measurements noticed that plasma treated polyetherurethane surface is more negatively charge, and consequently attachment of the L929 fibroblast cells decreased whereas on silicones surfaces, negatively charge surfaces show increase cells attachment.

Animals↗