Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIO”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

[Radio-tracking of rabid foxes].

Three wild foxes were trapped, inoculated with rabid fox salivary glands virus and radio-tracked straightaway for about three weeks until the death of the animal. Comparison of movements between incubation and clinical period indicate principally no obvious alteration of the activity area; an important increase in movement, especially during the day-time and lastly some variable changes in the activity pattern according to the individual. A common characteristic was a long period of immobility, before death, near the border of the usual activity area. In connection with these remarks, many sub-cutaneous lesions were observed from bites on the body of one of these three foxes, after necropsy. Epidemiological consequences of these first results were argued, especially as far as transmission of rabies from one fox to another is concerned.

Animals↗

High efficiency gene transfection by electroporation using a radio-frequency electric field.

In order to develop a safe and effective way to introduce exogenous genes into cells, we have experimented with a new method of electroporation which uses a radio-frequency (RF) electric field to permeabilize the cell membrane. This RF method has several advantages over the conventional electroporation method which uses a direct current (DC) field. We have shown that the RF electroporation method can be used to introduce marker genes into a wide variety of cell lines, including COS-M6, CV-1, CHO, 3T3 and hepatocytes, and is able to increase substantially the efficiency of gene transfection. (For example, the amount of DNA required for transfecting two million COS-M6 cells can be as low as 0.1 microgram). The transfection efficiency is shown to be affected by a number of factors, including cell type, field strength, pulse protocol and medium buffer. Because of its wide range of applications, high transfection efficiency and lack of harmful side-effect, the RF electroporation method would be particularly useful for introducing genes into human cells for gene therapy.

Animals↗

Comparative effectiveness of hypothermia rewarming techniques: radio frequency energy vs. warm water.

The purpose of this study was to compare the rewarming effectiveness of a radio frequency coil (13.56 MHz) at a specific absorption rate (SAR) of 2.5 W/kg (RF) with warm water immersion (40 degrees C) (WW) and an insulated mummy-type insulating sack (IS) under simulated field conditions. Four male subjects, ages 24-35, were immersed in 10 degrees C water for up to 90 min or until their rectal temperatures (Tre) decreased to 35 degrees C. Each subject had 3 trials in which they were immersed. After each immersion, rewarming was accomplished with either RF, WW, or IS, so that each subject was rewarmed once with each method. Comparisons of the 3 rewarming methods were based on the rate of increase of Tre during rewarming (Tre/t), Tre 60 min after the start of rewarming (Tre60), the time-interval measured from extraction from the water to the end of afterdrop (tad), and the magnitude of any observed Tre afterdrop (Tad). WW had significantly greater Tre/t and Tre60 than either RF or IS (P < 0.03) and a smaller tad than IS (P < 0.05). IS had significantly greater Tad than either WW or RF (P < 0.05). No significant differences in Tre/t, Tre60, or tad were observed between IS and RF. The results of this study indicate that for mildly hypothermic individuals, active rewarming with RF at a SAR of 2.5 W/kg is less effective than WW and roughly equivalent to passive rewarming with IS.

Adult↗

Rigidity in rats due to radio frequency decerebration and effects of chlorpromazine and mephenesin.

Bilateral radio frequency (RF) lesions of the midbrain were produced in an attempt to establish a non-bleeding method of producing decerebrate rigidity in rats. Marked extensor rigidity occurred with a high reproducibility in hindlimbs without the appearance of voluntary movement. Stretch reflex tension induced by repetitive dorsiflexion of the hindfeet was employed as a measure of the intensity of rigidity. Chlorpromazine-HCl (0.1-1 mg/kg, i.v.) and mephenesin (10-50 mg/kg, i.v.) which depress intercollicular decerebrate rigidity, reduced the RF decerebrate rigidity. These results suggest that RF decerebrate rigidity can be used instead of intercollicular transection rigidity in the pharmacological and physiological studies.

Animals↗

Radio frequency field intensity mapping using a composite spin-echo sequence.

A novel radio frequency (RF) field intensity mapping or imaging method using a composite NMR spin-echo sequence is proposed. A composite spin-echo RF pulse with 90 degrees y-180 degrees x-90 degrees y sequence makes phase change in the final image depending on the RF field intensity on the object. The resultant phase change or phase map can be used to obtain the actual RF flip-angle map for a given condition which includes the status of tuning and RF inhomogeneity, etc. Bloch equation has been solved numerically to obtain the effects of the RF field intensity as well as the main magnetic field inhomogeneity and the results are used for the mapping (imaging) of the RF field intensity. Phantom studies have been performed using a 1.5 Tesla whole body MRI system and the results are presented.

Humans↗

Improved MR imaging in extremely inhomogeneous radio-frequency fields.

An improvement to the method for imaging with extremely inhomogeneous radio-frequency fields is presented which uses a pseudo-noise-modulated selective (PNMS) excitation prepulse to randomize the signal from outside the selected slice. This prepulse reduces the problems that arise from imperfect subtraction involved with the one-dimensional ISIS-type slice selection procedures. The results demonstrate two to three times improvement in the signal-to-noise ratio and reduction in the image artifacts when this prepulse is used.

Computer Simulation↗

Vaginal temperature sensing using UHF radio telemetry.

User-induced errors are common when women repetitively employ conventional probe type thermometers to chart their basal body temperatures in an effort to indicate ovulation. An alternative technique employing a two-part telemetric thermometer is proposed, with low-power, SAWR-controlled UHF radio as the transmission medium. Worn overnight in the vagina, the 1 microW erp telemetry transmitter sends pulse modulated data continuously to a microcontroller in a nearby receiver; a real time clock enables programmable sampling and storage of the subject's temperature to 0.1 degrees C resolution. Initial clinical results indicate an enhanced performance compared to oral and axillary temperature trends taken by a mercury-in-glass thermometer. Polar plots of both the isolated and body-worn telemetry transmitter are presented; body induced attenuations of up to 30 dB were measured.

Biomedical Engineering↗

Biological stress responses to radio frequency electromagnetic radiation: are mobile phones really so (heat) shocking?

Cells phenotypically adapt to alterations in their intra- and extracellular environment via organised alterations to gene and protein expression. Many chemical and physical stimuli are known to drive such responses, including the induction of oxidative stress and heat shock. Increasing use of mobile telephones in our society, has brought focus on the potential for radio frequency (microwave) electromagnetic radiation to elicit biological stress responses, in association with potentially detrimental effects of this to human health. Here we review evidence suggesting altered gene and protein expression in response to such emissions, with particular focus on heat shock proteins. Non-thermal induction of heat shock proteins has been claimed by a number of investigations in in vitro cellular systems, and appears pleiotropic for many other regulatory events. However, many of these studies are flawed by inconsistencies in exposure models, cell types used and the independent reproducibility of the findings. Further, the paucity of evidence from in vivo experimentation is largely contradictory. Therefore, the validity of these effects in human health risk assessment remain unsubstantiated. Where possible, suggestions for further experimental clarification have been provided.

Animals↗

Utility of the Safe-Cross-guided radiofrequency total occlusion crossing system in chronic coronary total occlusions (results from the Guided Radio Frequency Energy Ablation of Total Occlusions Registry Study).

The Safe-Cross radiofrequency guidewire (IntraLuminal Therapeutics, Carlsbad, California) combines 3 capabilities: (1) steerability of a conventional 0.014-in intermediate-stiffness guidewire, (2) optical coherence reflectometry to warn the operator when the wire tip approaches within 1 mm of the vessel wall, and (3) delivery of radiofrequency energy pulses to the wire tip to facilitate passage through an occluded segment. The Guided Radio Frequency Energy Ablation of Total Occlusions Registry was a prospective, nonrandomized, multicenter registry that enrolled 116 patients who had long-term coronary total occlusions and in whom a >10-minute good-faith attempt to cross the occlusion using conventional guidewires had failed. The median known duration of occlusion was 22 months (32%; >1 year), and the median length of the occluded segment was 25 mm (25%; >30 mm). Device success was achieved in 63 of 116 of patients (54.3%), and major adverse events occurred in 6.9%, consisting predominantly of isolated increases in cardiac enzymes with no procedure-related deaths, Q-wave myocardial infarctions, or emergency bypass operations. Clinical perforation occurred in 2.6% of patients; of these, perforation in only 1 patient (0.9%) was adjudicated to be directly related to the Safe-Cross radiofrequency wire rather than to the stiff and/or hydrophilic wires used after an inability to advance with the Safe-Cross. Based on these data, the device has been approved in Europe and was recently (January 2004) granted 510K clearance by the Food and Drug Administration.

Adult↗

Micro pulsed radio-frequency electroporation chips.

Electroporation (EP) is one of the most important physical methods in biotechnology, which employs electrical pulses to transiently permeabilize cell membranes. In this study, a new micro pulsed radio-frequency electroporation cell (microPREP) chip was fabricated using a lift-off technique and SU-8 photolithography. The biological tests were carried out using three different plant protoplasts (cabbage, spinach and oil rape) on the micro EP chip and a pulsed RF electric field was applied to the microchip. The variations of fluorescent intensity and cell viability as functions of the electric pulse amplitude and duration time during the electroporation process were studied in detail at the single-cell level. Using such chip design and test method, one can easily optimize the efficiency and cell viability. Also, a large amount of statistical data can be quickly obtained. Finally, results of this parametric study were presented in the "phase diagram", from which the critical electric field for inducing single-cell electroporation under different conditions can be clearly determined.

Brassica↗

Radio frequency (rf) plasma spheroidized HA powders: powder characterization and spark plasma sintering behavior.

The present study describes the synthesis of spheroidized hydroxyapatite (HA) powders using a radio frequency (rf) inductively coupled plasma (ICP) torch. The spheroidized powders were consolidated through a spark plasma sintering (SPS) system. The microstructure and crystallographic phases in the synthesized powders were characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffractometry (XRD) and Raman spectrometry. Results showed that the HA feedstock decomposed after rf plasma processing. Crystalline HA, alpha-tri-calcium phosphate (alpha-TCP), tetra-calcium phosphate (TTCP) and calcium oxide (CaO) were detected in the plasma-spheroidized powders. Raman spectra results indicated strong presence of amorphous calcium phosphate (ACP) in the spheroidized powders. The particle size distribution and specific surface area were influenced through the rf plasma working plate power levels. The sintering behavior of the rf plasma synthesized powders was analyzed through the SPS process and the results indicated that the spheroidized powders commence sintering at approximately 900 degrees C and through to 1150 degrees C. After sintering above 1100 degrees C for 3min, the relative densities of the SPS compacts reached 96% of the theoretical value. The SPS compacts were immersed in simulated body fluids (SBF) for different durations and the results confirmed their bioactivities.

Biocompatible Materials↗

Efficacy of radio frequency cooking in the reduction of Escherichia coli and shelf stability of ground beef.

The effectiveness of radio frequency (RF) cooking on the inactivation of Escherichia coli in ground beef and its effect on the shelf stability of ground beef were investigated with a comparison to hot water-bath cooking. E. coli K12 was used as a target bacterium instead of E. coli O157:H7. The ground beef samples inoculated with E. coli K12 (ampr) were heated until the centre temperature of each sample reached 72 degrees C. These samples were then stored at 4 degrees C for up to 30 days. The enumeration of E. coli K12, background E. coli and coliform counts in ground beef samples was carried out for shelf-life study. Although both methods significantly reduced E. coli K12 (ampr), E. coli and coliform counts and extended the shelf-life, RF cooking had a shorter cooking time, and more uniform heating. Thus, RF cooking of meat has a high potential as a substitute for the hot water-bath cooking.

Animals↗

Implantation of radio frequency identification device (RFID) microchip in disaster victim identification (DVI).

The tsunami catastrophe of December 2004 left more than 200,000 dead. Disaster victim identification (DVI) teams were presented with the unprecedented challenge of identifying thousands of mostly markedly putrefied and partially skeletised bodies. To this end, an adequate body tagging method is essential. Conventional body bag tagging in terms of writing on body bags and placing of tags inside body bags proved unsatisfactory and problem prone due to consequences of cold storage, formalin (formaldehyde) embalming and body numbers inside storage facilities. The placement of radio frequency identification device (RFID) microchips inside victim bodies provided a practical solution to problems of body tagging and attribution in the DVI setting encountered by the Austrian DVI team in Thailand in early 2005.

Austria↗

Millisecond pulsed radio frequency glow discharge time of flight mass spectrometry: temporal and spatial variations in molecular energetics.

The internal energy distributions, P(epsilon), of a millisecond pulsed radio frequency glow discharge plasma were investigated using tungsten hexcarbonyl W(CO)(6) as a "thermometer molecule". Vapor of the probe molecule, W(CO)(6), was introduced into the plasma and subjected to various ionization and excitation processes therein. The resultant molecular and fragment ions were monitored using a Time-of-Flight mass spectrometer. Ion abundance data were utilized in combination with the known energetics of W(CO)(6) to construct the P(epsilon) plots. The P(epsilon) of W(CO)(6) exhibited strong temporal dependence over the pulse cycle: Distinct internal energy distributions were found at the discharge breakdown period (prepeak), the steady state period (plateau), and the post-pulse period (afterpeak). Spatial variation in P(epsilon) was also observed, especially during the plateau regime. The observations suggest that this pulsed glow discharge affords excellent energy tunability that can be used to perform selective ionization and fragmentation for molecular, structural, and elemental information. Parametric studies were performed to evaluate the effects of discharge pressure and operating power on P(epsilon). These studies also provided insight into the correlation of the observed P(epsilon)s with the fundamental ionization and excitation mechanisms in the plasma. The temporal and spatial variations in P(epsilon) were hence attributed to changes in the dominant energy transfer processes at specific times in specific regions of the plasma. These data will be useful in future efforts to optimize the analytical performance of this source for chemical speciation.

Air Ionization↗

Reducing nitric oxide into nitrogen via a radio-frequency discharge.

NO/N(2)/O(2)/H(2)O mixtures are usually converted into HNO(3) and/or NO(2) using different discharge approaches. In this study, a radio-frequency discharge was successfully used to reduce NO mainly into N(2) at a low pressure (4kPa). The influences of experimental parameters, including carrier gas, inlet concentration of NO, O(2), steam, and applied power, are discussed. At least 95.7% of the total N atoms converted from NO into N(2). Other traces of byproducts were N(2)O and HNO(2), but neither HNO(3) nor NO(2) were detected. In addition, conversion of NO apparently increased with elevated applied power or decreased inlet concentration of O(2), reaching 92.8% and 74.2% for the NO/N(2)/O(2) (2%) and NO/N(2)/O(2) (6%)/H(2)O (10%) mixtures, respectively, at 120W. In addition, from the optical emission spectra, a large amount of N(2) (first positive band and second positive band) and NO (gamma system) were observed, and the important reactions for NO removal and N(2) formation are proposed.

Air Pollutants↗

Cross polarization, radio frequency field homogeneity, and circuit balancing in high field solid state NMR probes.

Homogeneous radio frequency (RF) fields are important for sensitivity and efficiency of magnetization transfer in solid state NMR experiments. If the fields are inhomogeneous the cross polarization (CP) experiment transfers magnetization in only a thin slice of sample rather than throughout the entire volume. Asymmetric patterns have been observed in plots of the CP signal versus RF field mismatch for an 800 MHz solid-state NMR probe where each channel is resonated in a single-ended mode. A simple model of CP shows these patterns can be reproduced if the RF fields for the two nuclei are centered at different places in the coil. Experimental measurements using B1 field imaging, nutation arrays on extremely short NMR samples, and de-tuning experiments involving disks of copper incrementally moved through the coil support this model of spatially offset RF fields. We have found that resonating the high frequency channel in a double-ended or "balanced" mode can alleviate this field offset problem, and have implemented this in a three-channel solid state NMR probe of our own design.

Adamantane↗

Detection of NMR signals with a radio-frequency atomic magnetometer.

We demonstrate detection of proton NMR signals with a radio-frequency (rf) atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz1/2 using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 MHz.

Equipment Design↗

Basic characteristics of the radio imaging method for biomedical applications.

The radio imaging method (RIM), a technology used practically for geophysical surveys, was applied to biomedical measurements. The characteristics of a subject between a pair of simple loop antennas were measured by using a feeble electromagnetic wave of low frequency. Water distribution inside the human body was expected to be measured, as well as the original method imaged mineral distributions. In geophysical surveys, finer resolution is provided than a wavelength of the electromagnetic wave. This was also expected for biomedical measurements. An acrylic water tank was used as a phantom of the abdominal portion of the human body, and basic measurements were performed with the phantom. The inner tank of the phantom, whose cross section was 6 x 8 cm, was detected by the method when the frequency was 54 MHz or the wavelength was nearly 6 m in free space. The resolution provided by the experiment suggested that the proposed method was effective even if the wavelength was longer than the dimensions of the targeted area. The advantage of the method is simplicity, economy and safety. The authors are looking for specific applications for example, a urination sensor or a vital monitor for in-home care, where the strong points of the method are suitable.

Abdomen↗