Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Protective Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

The Efficacy of Directional Atherectomy Prior to Stent Implantation.

Coronary stents have improved the short- and long-term outcomes of patients undergoing catheter-based coronary interventions. However, the use of these devices in complex coronary lesions has also created an incessant form of in-stent restenosis that still defies treatment. Plaque burden has been consistently and reproducibly recognized as an important factor that may incite neointimal proliferation after stent implantation. Prospective nonrandomized experience has shown that plaque removal prior to stent implantation using directional atherectomy is a promising approach to reduce restenosis in selected patients. However, the proof of concept awaits the results of the randomized trials. Ultimately, the clinical use (safety and efficacy) of this approach will depend on 1) further improvements on the current directional atherectomy device to make it user friendly; 2) minimizing the incidence of non-Q-wave myocardial infarction with selective use of IIb-IIIa platelet receptor antagonists or distal protection devices; and 3) targeting patients at high risk for restenosis in whom efficient debulking is feasible. This would include patients who have noncalcified lesions in vessels greater than 2.75 mm but less than 3.5 mm in diameter that require a long stent or multiple stents, aorto-ostial lesions, bifurcational lesions, and chronic total occlusions.

Journal Article↗

Renal angioplasty and stent placement with distal protection: preliminary experience with the FilterWire EX.

Percutaneous transluminal renal angioplasty and stent placement with use of a coronary protection device was performed in a total of four patients with hypertension (n = 4) and/or renal insufficiency (n = 3) referred for revascularization of five renal arteries. Renal revascularization was successful in all five renal arteries (100%), but renal revascularization under protection by the FilterWire EX was achieved in only three of five renal arteries (60%). In one of these three, only a suboptimal seal was achieved between the vessel wall and the filter basket. Nevertheless, use of the device was safe and fibrin and/or cholesterol fragments were retrieved from three renal arteries. The FilterWire EX needs to be modified for the renal circulation to achieve the full theoretical advantages of these systems in this vascular bed.

Aged↗

[Radiometric survey during hemodynamic studies with "Siemens Angioskop D" equipment].

PURPOSE: To provide data for professional specialized in these subjects, contributing to minimize their exposure radiation dosage. METHODS: We made a radiometric survey using a ionization chamber to check the exposure rate in several places in the examination's room to different operational conditions of X-ray equipment. RESULTS: The operational conditions on which we have gotten the highest scatter X-ray rate were: image intensifier with 17cm of diameter for left anterior oblique projection (45 degrees) and image intensifier with 27cm of diameter for perpendicular beam to the patient (0 degrees). During fluoroscopy and cinefilm mode we have got average reduction of 40% for scatter X-ray using the image intensifier of 27 cm of diameter. During the cinefilm the dose rates were 23 times bigger than the dose rate in fluoroscopy mode. CONCLUSION: An analysis of results show that the choice of X-ray entrance angle as well as the diameter of image's intensifier during the cinefilm and fluoroscopy mode change significantly the occupational exposure dosages. Considering that in this kind of procedure, physicians and assistants spent long time close to the patient, they should have special concern to observe the technical condition more appropriate as well as to make use of all protection devices to minimize the personnel dosage.

Cardiology↗

Prevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection.

BACKGROUND: Although distal embolization and the "no-reflow" phenomenon are well described in saphenous vein graft (SVG) interventions, the frequency, magnitude, and characterization of embolized debris have not been evaluated in routine coronary interventions. A unique embolus protection device described herein provides a means of containing and retrieving plaque material dislodged during percutaneous coronary interventions. This report details the first clinical experience of the effectiveness and safety of an emboli protection system in 11 SVG lesions and 15 native coronary artery lesions. METHODS AND RESULTS: The AngioGuard Emboli Capture Guidewire (Cordis) consists of a PTCA wire with an expandable filter at the distal tip. The porous membrane permits normal distal blood flow, while trapping potential emboli by filtration. After crossing the lesion, the filter is expanded, and routine angioplasty is performed over the same wire. Emboli retrieval is achieved by collapsing the filter and retracting the emboli capture wire (ECW). In 26 patients, standard angioplasty was performed over the ECW; 20 of these 26 patients received a stent. Collected debris was sent for histopathological analysis. Plaque debris was retrieved after native coronary and SVG interventions in all cases. The ECW was positioned and retrieved without complications. No major adverse events occurred. Myocardial infarctions and no-reflow were not observed. CONCLUSIONS: The embolization of plaque fragments frequently occurs during coronary and SVG intervention. Distal embolization leading to microvascular obstruction and no-reflow could be successfully minimized by using the ECW.

Adult↗

Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield.

Shielding the radiosensitive gonads during X-ray exposure has been advocated for plain film radiography for many years. In the UK, gonad shields are not widely employed in routine CT scanning, possibly owing to a perceived difficulty in protecting the gonads from a multidirectional X-ray source. The increasing numbers of CT scanners in the UK, with the large doses they deliver to patients, make potential dose reduction methods an important issue. This study measures the dose reduction achievable by shielding the male gonads with a lead wrap-around protection device. The reductions in dose when shielded both from direct radiation and from indirect radiation scattered from local tissues were studied. The use of the device resulted in a statistically significant reduction in the absorbed testicular dose from both direct and scattered radiation, with no increase in the dose measured in surrounding tissues. In three clinically relevant experimental protocols where the testes were not irradiated directly, the testicular absorbed dose from indirect scatter was reduced by 77-93% of the corresponding non-shielded figure. In these three experiments, image quality was unaltered by the use of the shield. A larger dose reduction was obtained when the shield was used to protect the testes from direct irradiation. However, this was achieved at the expense of considerable image degradation from streak artefact that would effectively prevent the clinical use of the device in this setting.

Gonads↗

The effects, risks, and guidelines for radiation use in orthopaedic surgery.

Radiation is used during orthopaedic surgery in more than 15 million studies performed yearly. The biologic effects of radiation have been shown to inhibit mitosis by producing irrepairable deoxyribonucleic acid double strand breaks or create structural changes by damaging the nucleus, thereby producing potential genetic transmissions. Although human cells are thought to be resistant to malignant change and no studies have shown toxic effects resulting from long-term exposure to low-dose radiation, risks still are assumed. To decrease all risks, radiographic units should undergo periodic calibration, surgeons should wear protective devices, increase their working distance from the x-ray beam, and limit their duration of radiation exposure by making certain that they follow the guidelines set forth by the National Council for Radiation Protection and Measurement.

Fluoroscopy↗

Renal angioplasty and stenting under protection: the way for the future?

The purpose of this study was to evaluate the feasibility and safety of renal artery angioplasty and stenting utilizing a distal protection device to reduce the risk of intraprocedural artery embolism and avoid deterioration of the renal function. Fifty-six hypertensive patients (32 men; mean age, 66 +/- 11.8 years; range, 22-87) with atherosclerotic renal artery stenosis (8 bilateral) underwent angioplasty and stenting with distal protection in 65 renal arteries (58 ostial lesions). Five patients had a solitary kidney, 18 a renal insufficiency. The lesion was crossed either with a GuardWire temporary occlusion balloon (n = 38), which was inflated to provide parenchyma protection or with a filter (EPI Filter; n = 26), or with Angioguard (n = 1), which allows a continuous flow. Generated debris was aspirated and analyzed. Blood pressure and serum creatinine levels were followed. Immediate technical success was 100%. All lesions except one were stented, either directly (43 ostial lesions) or after predilatation (22 ostial lesions). Visible debris were aspirated with the PercuSurge in all patients or removed with filters in 80% of the patients. Mean particle number and diameter were 98.1 +/- 60.0 per procedure (range, 13-208) and 201.0 +/- 76.0 microm (range, 38-6,206), respectively. Mean renal artery occlusion time was 6.55 +/- 2.46 min (range, 2.29-13.21) with the PercuSurge device. Mean time in situ (filters) was 4.25 +/- 1.12 min. Mean follow-up was 22.6 +/- 17.6 months (range, 1-47). Systolic and diastolic blood pressure declined from 169.0 +/- 15.2 and 104.0 +/- 13.0 mm Hg, respectively, to 149.7 +/- 12.4 and 92.7 +/- 6.7 mm Hg after the procedure. The mean creatinine level remains constant during the follow-up. At 6-month follow-up (45 patients), renal function did not deteriorate in any patient, whereas 8 patients with baseline renal insufficiency improved after the procedure. At 3 years (19 patients), renal function deteriorated only in 1 patient with renal insufficiency and in 1 patient treated for bilateral renal stenosis, one side without protection. These preliminary results suggest the feasibility and safety of distal protection during renal interventions to protect against atheroembolism and to avoid renal function deterioration. This technique's beneficial effects should be evaluated by randomized studies.

Adult↗

[Late complications after transcatheter closure of atrial septal defect].

The transcatheter closure of atrial septal defects is generally accepted as an alternative to surgical therapy in selected patients. Potential complications of these devices are a matter of concern, as well as the very complicated implantation technique required for some systems. We report on a 17 year old patient in whom embolization of a fractured umbrella arm into a peripheral branch of the left pulmonary artery occurred. A 35 mm-ASDOS-Device (protected trademark of the Dr. Osypka GmbH/Grenzach-Wyhlen, Germany) had been implanted 4 years ago. The perfusion scintigraphy of the left lung showed normal pulmonary blood flow. Echocardiography failed to demonstrate instability of the double-umbrella device. The patient was always free of any symptoms. Due to the permanent stresses between device and heart, late fractures of the device and embolizations of fragments are possible. It can be concluded that patients who underwent transcatheter closure of an ASD require lifelong follow-up.

Adolescent↗

[Investigations of radiation exposure of the medical personnel during F-18-FDG PET studies].

AIM: The aim of the investigation was the identification of those working steps with the highest radiation exposure for the medical personnel during F-18-FDG-PET studies and to evaluate the effectiveness of radiation protection devices and instructions developed in our PET-center. METHODS: The personal dose and hand dose were measured for each working procedure during F-18-FDG-PET studies using electronic personal dosimeters and thermoluminescent dosimeters respectively. Additionally, measurements of the radiation level near the patient were taken. RESULTS: The mean personal dose resulting from syringe preparation was 1 microSv/syringe, from injection 3 microSv/patient, from blood sampling during quantitative studies 6 microSv/study, and from positioning and handling of the patient 6 microSv/study. The mean hand dose per syringe preparation was 710 microSv for each hand. The mean hand dose during injection was 13 microSv for the right hand and 27 microSv for the left hand. All above mentioned values were measured applying the routine radiation shielding in use in our PET center. CONCLUSION: With the developed radiation shielding and means to reduce radiation exposure applied the allowed annual dose for medical personnel are not exceeded. One exception is the hand dose resulting from syringe preparation. An automatic or remote filling device should be used at this working step.

Fluorodeoxyglucose F18↗

[A case of carotid occlusive disease treated with stenting for recurrence of stenosis: strategy on intolerance to temporary occlusion].

Carotid artery stenting has emerged as an acceptable treatment alternative in patient with occlusive carotid bifurcation disease. High-risk surgical candidates have a lower rate of morbidity after carotid artery stenting with distal embolic protection. Among distal protection devices, a Guardwire balloon occlusion is the most frequently employed in Japan. A 79-year-old male who had severe stenosis at the origin of left carotid artery was treated with stenting under Guardwire balloon protection. He was intolerant to carotid artery occlusion and endovascular procedures were performed under intravenous anesthesia or general anesthesia. In addition, he suffered recurrent stenosis seven months after the first procedure and 16 months after second procedure, and underwent repeated intervention. It was considered that the long tortuous lesion was a cause of the recurrent stenosis.

Aged↗

[A portable miniature IMD-01 X-ray dosimeter for monitoring the dose power in radiodiagnosis].

The paper presents a portable miniature [symbol: see text]-01 X-ray dosimeter designed by the Research Institute of Introscopy, Spektr Moscow Research-and-Production Association, for monitoring the power of a dose during X-ray diagnosis. The device ensures the monitoring of the power of a dose at the input of X-ray detectors of diagnostic apparatuses and, with the use of special methods, makes it possible to control the state of the protection devices of X-ray diagnostic apparatuses. An ionization chamber is used as a detector of X-ray radiation. The technical data of the dosimeter are given.

Equipment Design↗

Prospective noise induced changes to hearing among construction industry apprentices.

AIMS: To characterise the development of noise induced damage to hearing. METHODS: Hearing and noise exposure were prospectively monitored among a cohort of newly enrolled construction industry apprentices and a comparison group of graduate students, using standard pure tone audiometry and distortion product otoacoustic emissions (DPOAEs). A total of 328 subjects (632 ears) were monitored annually an average of 3.4 times. In parallel to these measures, noise exposure and hearing protection device (HPD) use were extensively monitored during construction work tasks. Recreational/non-occupational exposures also were queried and monitored in subgroups of subjects. Trade specific mean exposure L(eq) levels, with and without accounting for the variable use of hearing protection in each trade, were calculated and used to group subjects by trade specific exposure level. Mixed effects models were used to estimate the change in hearing outcomes over time for each exposure group. RESULTS: Small but significant exposure related changes in DPOAEs over time were observed, especially at 4 kHz with stimulus levels (L1) between 50 and 75 dB, with less clear but similar patterns observed at 3 kHz. After controlling for covariates, the high exposure group had annual changes in 4 kHz emissions of about 0.5 dB per year. Pure tone audiometric thresholds displayed only slight trends towards increased threshold levels with increasing exposure groups. Some unexpected results were observed, including an apparent increase in DPOAEs among controls over time, and improvement in behavioural thresholds among controls at 6 kHz only. CONCLUSIONS: Results indicate that construction apprentices in their first three years of work, with average noise exposures under 90 dBA, have measurable losses of hearing function. Despite numerous challenges in using DPOAEs for hearing surveillance in an industrial setting, they appear somewhat more sensitive to these early changes than is evident with standard pure tone audiometry.

Adult↗

Passive air sampling using semipermeable membrane devices at different wind-speeds in situ calibrated by performance reference compounds.

Semipermeable membrane devices (SPMDs) are passive samplers used to measure the vapor phase of organic pollutants in air. This study tested whether extremely high wind-speeds during a 21-day sampling increased the sampling rates of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs), and whether the release of performance reference compounds (PRCs) was related to the uptakes at different wind-speeds. Five samplers were deployed in an indoor, unheated, and dark wind tunnel with different wind-speeds at each site (6-50 m s(-1)). In addition, one sampler was deployed outside the wind tunnel and one outside the building. To test whether a sampler, designed to reduce the wind-speeds, decreased the uptake and release rates, each sampler in the wind tunnel included two SPMDs positioned inside a protective device and one unprotected SPMD outside the device. The highest amounts of PAHs and PCBs were found in the SPMDs exposed to the assumed highest wind-speeds. Thus, the SPMD sampling rates increased with increasing wind-speeds, indicating that the uptake was largely controlled by the boundary layer at the membrane-air interface. The coefficient of variance (introduced by the 21-day sampling and the chemical analysis) for the air concentrations of three PAHs and three PCBs, calculated using the PRC data, was 28-46%. Thus, the PRCs had a high ability to predict site effects of wind and assess the actual sampling situation. Comparison between protected and unprotected SPMDs showed that the sampler design reduced the wind-speed inside the devices and thereby the uptake and release rates.

Air Pollutants↗

Changing epidemiology of injury-related pediatric mortality in a rural state: implications for injury control.

STUDY OBJECTIVE: To document the current epidemiology of pediatric injury-related deaths in a rural state and evaluate changes over time. DESIGN: Retrospective review of injury-related deaths in children less than 15 years of age. Data were obtained from death certificates and coroner, autopsy, prehospital, and hospital records. Analysis was done of the mechanism of injury, age, sex, race, location of incident, toxicology, and safety device use. Comparisons with analogous data collected from an earlier time period were made. SETTING: The state of Montana, from October 1989 to September 1992. MEASUREMENTS: Deaths per 100,000 population, intentionality of injury, mechanism of injury, use of protective devices, and comparisons with previous data (1980-1985) collected by Baker and Waller (Childhood injury: State by state mortality facts. Baltimore: Johns Hopkins Injury Prevention Center, 1989;148-152). RESULTS: Of 121 patients reviewed, 56% were male and 44% were female. Mean age was 7.0 years (median, 8.0). Eighty-one percent of patients were Caucasian, and 16% were Native American. The leading cause of injury was motor vehicle crashes, which was followed by drowning, unintentional firearm injuries, deaths related to house fires, homicides, and suicides. Overall, 87% of injuries were unintentional and 13% were intentional, with 62% of these suicides and 38% homicides. When considered independently of intent, firearm-related injuries ranked second. Earlier data showed motor vehicle crashes ranking second, unintentional firearm injuries seventh, and homicide fourth. Comparison of death rates per 100,000 people for the two time periods showed increases in suicide deaths (3.2 vs 0.8) and unintentional firearm injury deaths (2.3 vs 0.6). CONCLUSION: The epidemiology of rural pediatric injury-related deaths has changed. Deaths related to suicide and firearms have increased. Violent deaths related to injuries caused by firearms are at a magnitude approaching all other causes. These findings have implications for public health education and injury control strategies in rural areas.

Accidents, Traffic↗

[Prevention of hand-arm vibration syndrome by using antivibration gloves].

Hand-arm vibration syndrome induced by the exposure to mechanical vibration transmitted from power tools to the operator's hands contributes highly to the number of occupational diseases certified in Poland, as well as in other countries. Use of antivibration gloves is one of the methods for reducing the occupational risk of vibration damages. However, the number of researchers express certain reservations about the benefits from wearing such a protective device, mostly because of very limited scientific and explicit evidence to prove the effectiveness of antivibration gloves in preventing hand-arm vibration syndrome. But there is no controversy about the opinions that to achieve a maximum degree of protection, antivibration gloves should be selected to match particular vibratory tools, taking account of the vibration spectrum generated, by them. The paper presents the general principles of the glove selection, the results of the studies of the effectiveness of antivibration gloves carried out by the Central Institute for Labour Protection (CIOP), as well as some other results, opinions and ideas. The gathered data prove that antivibration gloves are a useful measure to prevent hand-arm vibration syndrome.

Arm Injuries↗

Chemical-biological warfare: medical logistics and defense.

In this article, the authors discuss some of the hard realities of chemical and biological warfare defense in terms of the medical and medical logistics implications. In the opinion of the authors, there are no adequate defensive measures at present which would protect troops and sailors from the effects of either chemical or biological warfare tactics. An overview of the current world situation is presented, as well as some of the clinical and logistical responses to chem-bio war. The effectiveness of vaccinations or other medical approaches to protecting service members from chem-bio attacks is questioned in light of the technology and of the unpredictability in guessing the agent's strain or nature (e.g. viral, bacterial, or chemical). An analysis of Mission Oriented Protective Posture gear, gas masks, and other potential external protection devices reveals them to be inadequate, impractical, or expensive. In short, whether facing known war arsenals or unknown terrorist possibilities, the armed forces of the United States when meeting chemical or biological agents will be hard-pressed to protect and heal themselves, much less the nation's civilian population.

Biological Warfare↗

Statin therapy at carotid angioplasty and stent placement: effect on procedure-related stroke, myocardial infarction, and death.

PURPOSE: To retrospectively determine if preprocedural statin treatment is associated with a reduction of cardiovascular events after carotid angioplasty and stent placement (CAS) in patients with symptomatic carotid stenosis. MATERIALS AND METHODS: A study resulting in a prospective database was approved by the institutional ethics review board; written informed consent was obtained. The approval and informed consent included future retrospective analysis. Consecutive patients (n = 180) from the prospective database underwent CAS for high-grade symptomatic carotid disease. The frequency of cardiovascular complications (composite of stroke, myocardial infarction, and death within 30 days after CAS) between 127 patients without preprocedural statin treatment and that of 53 patients with preprocedural statin treatment at CAS were compared with chi2 and multivariate logistic regression analysis. RESULTS: The overall 30-day myocardial infarction rate was two of 180 (1%) patients, the minor stroke rate was 16 of 180 (9%) patients, the major stroke rate was one of 180 (0.5%) patients, and the death rate was two of 180 (1%) patients. The incidence of cardiovascular events (composite of stroke, myocardial infarction, and death within 30 days after CAS) was significantly different between patients with preprocedural treatment (4%) and those without preprocedural statin treatment (15%) (P < .05). These higher complication rates among patients without preprocedural statin treatment were not mediated by adjustment for age, sex, other baseline characteristics, degree of carotid stenosis, use of cerebral protection devices, or the year in which CAS was performed. CONCLUSION: Preprocedural statin therapy appears to reduce the incidence of stroke, myocardial infarction, and death within 30 days after CAS. Future prospective randomized trials are warranted to further assess this potential protective effect of statin drugs during carotid interventions.

Aged↗

Endovascular stenting for stenoses in surgically reconstructed brachiocephalic bypass grafts: immediate and midterm outcomes.

PURPOSE: To report the use of endovascular stenting for treatment of patients with symptomatic obstruction of brachiocephalic surgical reconstructions. METHODS: Twenty-two patients (17 men; mean age 65+/-6 years) with 24 symptomatic obstructions of brachiocephalic Dacron bypass grafts (2 aorto-innominate, 9 subclavian-carotid, and 11 carotid-subclavian) were treated with balloon-expandable stents delivered via a percutaneous brachial access or surgical exposure of the common carotid artery. A distal protection device was utilized in the 9 patients with subclavian-carotid bypass grafts. All patients were followed by clinical and Doppler examinations. RESULTS: Procedural success was 100%; 1 (4.5%) patient developed transient intraprocedural aphasia owing to intolerance to the distal protection balloon occlusion. All 22 patients reported complete relief of their presenting symptoms. Over a 29-month follow-up, 3 (13.6%) restenoses were found, but none was due to stent compression. CONCLUSIONS: Stenting for obstructed brachiocephalic reconstructions appears to be a safe, effective, and durable therapeutic strategy.

Aged↗