Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Partial Pressure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

[Comparison between the Eppendorf histograph and the Licox system for determination oxygen partial pressure in tumor tissue].

BACKGROUND: The oxygenation of a tumor is certainly one of the major facts influencing the response to treatment. pO2 measurement in tumor tissue can be done by using the Eppendorf-histograph. In recent years the Licox-system (GMS) was developed for oxygen tension measurement in tissues and fluids under clinical routine conditions and for research work. Aim of the present study was to assess the suitability of the Licox-system in drawing up histograms of pO2 values in tumor tissues. METHOD: Histograms of the distribution of oxygen tension in twelve tumors were prepared with both measuring systems in parallel. Investigations were performed on rats with isotransplanted R1H rhabdomyosarcomas in continuous intravenous anesthesia with Fentanyl and Dormicum. Ventilation with a mixture of air and oxygen was applied through a tracheostoma. Arterial pressure and body temperature were analysed and balanced continuously. RESULTS: No correspondence between data of both measuring methods could be found. CONCLUSIONS: Because of constructional advantages the Eppendorf-histograph seems to be comparatively more suitable in drawing up histograms of oxygen tension tumor tissue.

Animals↗

[Simultaneous measurements of end-expiratory and transcutaneous carbon dioxide partial pressure in ventilated premature and newborn infants].

BACKGROUND: The aim of the present trial was to study the relationship between end-tidal pCO2 (p(et)CO2) and transcutaneous pCO2 (ptcCO2) after in-vivo calibration in ventilated newborns. PATIENTS: 61 end-tidal and transcutaneous pCO2 measurements were simultaneously performed in 30 ventilated preterm and term newborn infants (weight at birth 1862.6 +/- 981.9 g). METHOD: End-tidal pCO2 was measured in mainstream mode at the end of the endotracheal tubus (Novametrix 7000 Medical Systems Inc., USA, dead volume of the chamber 0.6 ml). Transcutaneous pCO2 was measured by means of a Servomed (SMK 365 Hellige, FRG) analyser. RESULTS: The statistical analysis demonstrated a good correlation (r = 0.72, p < 0.001) between ptcCO2 (mean +/- SD, 44.3 +/- 11.2 mmHg) and p(et)CO2 (32.4 +/- 10.4 mmHg). A considerable difference between transcutaneous and end-tidal pCO2 values was observed (p(tc-et)CO2 = +11.9 +/- 8.7 mmHg). This phenomenon was probably caused by ventilation-perfusion disturbances in the studied critically ill neonates. The statistical analysis revealed that the absolute magnitude of the P(tc-et)CO2 difference was independent from disease, episodes of spontaneous respiration or of respiratory frequency. CONCLUSIONS: Capnographic determination of P(et)CO2 provides informations about alveolar ventilation-perfusion-disturbances. Capnography enables the on-line control of end-tidal pCO2 in neonates with respiratory failure. It cannot replace transcutaneous pCO2 measurements or blood gas analysis but it can reduce its frequency in clinically stable patients. The analysis of the capnogram can be used to optimise artificial ventilation. A quantitative evaluation of the capnogram by calculation of Murányi's-CO2-Index was possible only in 28% of the ventilated newborns which limits its value in such patients.

Birth Weight↗

[Ocular circulatory changes in halothane-nitrous oxide intubation anesthesia with special reference to arterial CO2 partial pressure. I. Phenomenology of changes].

UNLABELLED: In 20 patients (5 with cataract, 15 with strabismus), general anesthesia was performed using halothane (inspiratory concentration: 0.5 vol.%) and nitrous oxide (65 vol.%); thiopental was employed for induction of anesthesia, vecuronium and succinylcholine were used for neuromuscular blockade prior to intubation. In series 1, the patients were slightly hyperventilated (PCO2 33 mmHg, on average). In series 2, the arterial PCO2 was changed in a range between 20 and 45 mmHg. By means of oculo-oscillo-dynamography, we determined the systolic retinal and ciliary perfusion pressures (PPs,ret and PPs,cil) as well as the respective ocular blood pressures (Ps,ret and Ps,cil), the ocular pulsation volume (PVoc) and the pulsatile ocular blood flow (Fp,oc = PVoc x heart rate). The intraocular pressure (Pio) was measured with the Draeger hand-applanation tonometer. Results of series 1: Measured 5 and 15 min after intubation, PPs,ret was reduced by averages of 12.5 and 20.2 mmHg, respectively, corresponding to decreases of 13.1 and 21.2% compared to the initial values. Ps,ret was decreased by 15.4 mmHg (14.2%) 5 min after intubation and by 27.1 mmHg (25.0%) 15 min after intubation. The ciliary pressures (PPs,cil and Ps,cil) were changed by similar amounts. PVoc was reduced by 0.3 microliters (50.8%) during both time periods after intubation. Fp,oc was lowered by 19.5 microliters/min (41.0%) and by 26.4 microliters/min (55.5%), measured 5 and 15 min after intubation, respectively. Pio was decreased by 1.6 mmHg (11.3%) and by 7.6 mmHg (53.5%), respectively. The systolic brachial artery pressure was reduced by 12.6 mmHg (9.5%) 5 min after intubation and by 29.1 mmHg (21.9%) 15 min after intubation. The diastolic branchial artery pressure showed a slight initial increase, followed by a small decrease. All changes were highly significant (P less than 0.001; 1-factor analysis of variance plus Scheffé test). Results of series 2: In a PCO2 range between 40 and 45 mmHg (normo-until slight hypoventilation; determined 5 min after intubation), PVoc and Fp,oc averaged 0.43 microliter and 42.9 microliters/min, respectively. In a PCO2 range between 30 and 35 mmHg (slight hyperventilation), PVoc and Fp,oc averaged 0.38 microliters and 36.1 microliters/min, respectively; and in a PCO2 range between 20 and 25 mmHg (forced hyperventilation), they averaged 0.21 microliter and 22.8 microliters/min, respectively. All other variables were not dependent on the PCO2 level. CONCLUSIONS: The lowering of PVoc and Fp,oc, observed during halothane-nitrous oxide anesthesia--especially with forced hyperventilation-, may be interpreted as reduced pulsatile choroidal blood flow.(ABSTRACT TRUNCATED AT 400 WORDS)

Aged↗

[Changes in ocular circulation in halothane-nitrous oxide intubation anesthesia with special reference to the arterial CO2 partial pressure. II. Mechanisms of change].

UNLABELLED: In part I of this study [Hessemer and associates, Klin. Mbl. Augenheilk. 199 (1991) 346-355] the phenomenology of the ocular circulatory changes, found during general anesthesia using halothane and nitrous oxide, has been described. These changes are analyzed with respect to their mechanisms.-- RESULTS: There was a significantly (P less than 0.05) linear relation between the anesthesia-induced reduction of the systolic ocular (retinal and ciliary) blood pressures and the decrease of the systolic brachial artery pressure (delta Ps,bra). The same relation was present between the reduction of the systolic ocular (retinal and ciliary) perfusion pressures and delta Ps,bra. The correlation coefficients for the designated relations ranged between 0.37 and 0.58. The relation between the anesthesia-induced intraocular pressure reduction and delta Ps,bra was--in tendency--linear (P = 0.07), at least for the time period 5-15 min after intubation; the correlation coefficient amounted to 0.37. The reduction of both the ocular pulsation volume (PVoc) and the pulsatile ocular blood flow (Fp,oc) did not depend on the systemic blood pressure, but on the arterial CO2 tension (PCO2): Decreasing PCO2--i.e., increasing hyperventilation--was paralleled by decreases of PVoc and Fp,oc. The relations PVoc vs. PCO2 and Fp,oc vs. PCO2 were significantly linear (P less than 0.01), the correlation coefficients ranged between 0.58 and 0.7.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, Endotracheal↗

Leaf O(2) uptake in the dark is independent of coincident CO(2) partial pressure.

Elevated CO(2), in the dark, is sometimes reported to inhibit leaf respiration, with respiration usually measured as CO(2) efflux. Oxygen uptake may be a better gauge of respiration because non-respiratory processes can affect dark CO(2) efflux in elevated CO(2). Two methods of quantifying O(2) uptake indicated that leaf respiration was unaffected by coincident CO(2) level in the dark.

Carbon Dioxide↗

Prediction of arterial oxygen partial pressure from intrapulmonary venous admixture.

A short program was developed to predict the PaO2 at a given FIO2 by using arterial and mixed venous blood gas data obtained at an FIO2 of 1.0. Our program resolves Adair's equation and the shunt equation inversely, on the assumption that intrapulmonary venous admixture and the arteriovenous oxygen content difference remain constant during the study. The study was conducted on 19 patients with respiratory failure who were intubated and mechanically ventilated. According to linear regression analysis, regression coefficients of 0.91 and 0.97 were obtained between the measured PaO2 values and those estimated by the arterial/alveolar oxygen tension ratio (PaO2/PaO2) and our program, respectively (n = 23). The PaO2 values were predicted more accurately by our program than those calculated by PaO2/PaO2. Because our program is simple enough to be carried out with a pocket computer, it may be helpful in a bedside decision of lowering FIO2, especially in patients who require a high FIO2 level to maintain sufficient arterial oxygenation.

Blood Gas Analysis↗

Effect of antihypertensive agents on the arterial partial pressure of oxygen and venous admixture after cardiac surgery.

OBJECTIVE: To determine whether stopping nitroglycerin and sodium nitroprusside (both vasodilators) infusions in hypertensive, postcardiac surgical patients requiring a high FIO2 improves PaO2 and venous admixture. DESIGN: Prospective, clinical trial. SETTING: Intensive care unit in a university-affiliated hospital. PATIENTS: Thirty postcardiac surgical patients who, because of high FIO2 requirements, did not meet the criteria for weaning from mechanical ventilation and who were receiving infusions of nitroglycerin and/or sodium nitroprusside to control blood pressure. INTERVENTIONS: PaO2, venous admixture, and oxygen transport data were determined at baseline using arterial and mixed venous blood gas samples and hemodynamic values from a pulmonary artery catheter. The nitroglycerin and sodium nitroprusside infusions were stopped, and intravenous boluses of labetalol were administered to maintain a target blood pressure. After the vasodilator infusions were stopped, the baseline measurements were repeated to redetermine PaO2, venous admixture, and oxygen transport values. MEASUREMENTS AND MAIN RESULTS: Results included a mean increase in PaO2 from 79.3 +/- 15 torr (10.5 +/- 2.0 kPa) to 118.3 +/- 38 torr (15.7 +/- 5.1 kPa) and a mean decrease in venous admixture from 26.4 +/- 5.8% to 17.6 +/- 5.6% when the vasodilators were stopped. All 30 patients had an increase in PaO2 and a decrease in venous admixture. Because of the improvement in oxygenation, 28 of the 30 patients met the criteria for weaning from mechanical ventilation once nitroglycerin and sodium nitroprusside were stopped or decreased. Labetalol was well tolerated in this group of patients who had preserved ventricular function. CONCLUSIONS: Substituting labetalol for nitroglycerin and sodium nitroprusside improves arterial oxygenation and venous admixture in hypertensive postcardiac surgical patients who require a high FIO2. This change in therapy may allow patients to be weaned from mechanical ventilation sooner.

Aged↗

Apnea testing guided by continuous transcutaneous monitoring of partial pressure of carbon dioxide.

OBJECTIVE: To continuously monitor PCO2 during two different protocols for apnea testing as part of the determination of brain death. DESIGN: Prospective comparative study using continuous transcutaneous PCO2 (tcPCO2) monitoring in 54 apnea tests with or without artificial CO2 augmentation. Another 53 apnea tests were not continuously monitored. SETTING: Intensive care wards in Northern Bavaria. PATIENTS: Ninety-six consecutive patients with suspected brain death. INTERVENTIONS: Apnea tests guided by transcutaneous monitoring during a PaCO2 of > or = 60 torr (> or = 8 kPa). MEASUREMENTS AND MAIN RESULTS: The mean of the difference between tcPCO2 and PaCO2 was -0.26 +/- 1.16 (SEM) torr (-0.035 +/- 0.15 kPa). Seventy percent of all transcutaneous measurements were within +/-10% of the PaCO2 values. The individual differences ranged from -25.8 to 16.9 torr (-3.44 to 2.25 kPa). CONCLUSIONS: While not as precise as could be desired in individual cases, the overall agreement between tcPCO2 and PaCO2 was good. Transcutaneous monitoring aided in effectively reducing the CO2 target overshoot with artificial CO2 augmentation, reduced the necessary number of blood gas checks compared with a former study, using predetermined time-locked evaluations, and prolonged only tests with artificial CO2 augmentation.

Adult↗

Photosynthetic Acclimation in Pea and Soybean to High Atmospheric CO2 Partial Pressure.

Nonnodulated pea (Pisum sativum L. cv Frosty) and soybean (Glycine max [L.] Merr. cv Wye) plants were grown under artificial lights from germination with ample nutrients, 600 [mu]mol photons m-2 s-1, and either 34 to 36 (control) or 64 to 68 Pa (enriched) CO2. For soybean, pod removal and whole-plant shading treatments were used to alter the source-sink balance and carbohydrate status of the plants. Growth of both species was substantially increased by CO2 enrichment despite some down-regulation of photosynthesis rate per unit leaf area ("acclimation"). Acclimation was observed in young pea leaves but not old and in old soybean leaves but not young. Acclimation was neither evident in quantum yield nor was it related to triose phosphate limitation of net photosynthesis. A correlation between levels of starch and sugars in the leaf and the amount of acclimation was apparent but was loose and only weakly related to the source-sink balance of the plant. A consistent feature of acclimation was reduced ribulose bisphosphate carboxylase (RuBPCase) content, although in vivo RuBPCase activity was not necessarily diminished by elevated growth CO2 owing to increased percentage of activation of the enzyme. A proposal is discussed that the complexity of photosynthetic acclimation responses to elevated CO2 is as an expression of re-optimization of deployment of within-plant resources at three levels of competition.

Journal Article↗