Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Inhalation Spacers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Delivery of salbutamol to nonventilated preterm infants by metered-dose inhaler, jet nebulizer, and ultrasonic nebulizer.

To identify the most efficient device for the delivery of bronchodilator aerosol to nonventilated preterm infants with chronic lung disease, we compared the metered dose inhaler (MDI) used in conjunction with a non-valved spacer, an ultrasonic nebulizer with a small medication cup, and two jet nebulizers. The subjects were enrolled in two double-blind randomized crossover studies. In study A (n=10), each infant was given a nominal dose of 200 microg of salbutamol by a MDI (Ventolin) at 4 h intervals, and in random sequence via an Aerochamber (Neonatal Aerochamber) with its one-way valve removed, an ultrasonic nebulizer with a small cone-shaped medication cup (Siemens Electronics), and a jet nebulizer (Side-stream). Their functional residual capacity (FRC) and static respiratory system mechanics were measured before, and at 15, 30, 60, and 120 min after aerosol delivery. Study B (n=10) was carried out in an identical manner, but with a different jet nebulizer (Hudson). In both studies, administration of salbutamol aerosol via the MDI Aerochamber or ultrasonic nebulizer resulted in a significantly greater reduction in respiratory system resistance than via jet nebulizers. Furthermore, the use of MDI Aerochamber or ultrasonic nebulizer was associated with a greater degree of post-treatment tachycardia and improvement in FRC. The bronchodilating effect of salbutamol delivered via the ultrasonic nebulizer appeared to be slightly greater than that via the MDI-Aerochamber, receiving significance only in Study B. We conclude that both the metered-dose inhaler used with a nonvalved Aerochamber and the ultrasonic nebulizer with a small medication cup are both more efficient than the jet nebulizers in preterm infants.

Albuterol↗

A non-electrostatic spacer for aerosol delivery.

A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The procedure prolonged the half life (t1/2) of the aerosol in the Nebuhaler from nine to 32 seconds. A normal cleaning procedure reduced the aerosol t1/2 back to baseline. The t1/2 of the aerosol in the metal spacer was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months to 6 years, suspected to have asthma the non-electrostatic spacer delivered a mean total dose of budesonide aerosol of 39% of the nominal dose, which was significantly higher than the Babyhaler (28%), the Nebuhaler (21%), and the AeroChamber (19%). These differences were most pronounced in children younger than 4 years. The improved dose delivery from the small volume non-electrostatic spacer is probably related to the non-electrostatic spacer material and the valves which assured unidirectional airflow from the spacer without adding any dead space in the inspiratory channel. The non-electro-static spacer should improve the cost effectiveness of aerosol treatment and, as the counteracting effects of proming and recharging of the plastic from cleaning are avoided, should deliver a more reliable dose.

Aerosols↗

Aerosol physiology, deposition, and metered dose inhalers.

The percentage of the dose reaching the lungs from a pressurized metered dose inhaler (MDI) is likely to be a major determinant of the efficacy of inhaled bronchodilators and corticosteroids. Yet MDIs may deposit no drug in the lungs in patients with poor inhaler technique and no more than 20% of the dose under optimum conditions. Spacer devices can help to deposit as much drug as from a correctly used MDI (even in patients with poor technique) but are often large and bulky. More compact (and easier to use) pressurized devices and multidose dry powder inhalers will be valuable additions to the range of apparatus available for asthma therapy and prophylaxis.

Administration, Inhalation↗

New beta 2-adrenergic agonist aerosols.

The beta 2-adrenergic agonists are reviewed in terms of their dose-response characteristics, and two newer agents, fenoterol hydrobromide and bitolterol mesylate aerosols, are reviewed in relation to older agents. The fenoterol aerosol contains a more potent beta 2-adrenergic agonist dose per puff than the other aerosols but, when given in equipotent doses, offers no advantage over available agents. Bitolterol mesylate is a prodrug that is hydrolyzed to the active beta 2-adrenergic agonist colterol by lung esterases. Bitolterol demonstrates an improved bronchoselectivity in animals, but there are insufficient comparative data in humans. Tachycardia is the dose-limiting toxicity for all beta 2-adrenergic agonists. Currently available data do not suggest an important improvement in duration of action for the newer agents over terbutaline or albuterol. Aerosol administration improves bronchoselectivity of all the agents. Optimal use of beta 2-adrenergic agonist aerosols requires understanding of the variable dose-response characteristics. The type of delivery system and patient technique are important variables in determining the dose delivered. Tube-spacer devices attached to aerosol canisters can significantly improve delivery of the beta 2-adrenergic agonists to the lungs in patients unable to synchronize actuation and inspiration. They provide minimal to no improvement in patients who can perform the appropriate technique. Aerosol administration is the route of choice for beta 2-adrenergic agonists for prophylaxis of exercise-induced bronchospasm; albuterol and terbutaline provide a prolonged duration of action with excellent beta 2-adrenergic selectivity. Patients should be carefully instructed in the optimal use of metered-dose inhalers, and some patients may benefit from use of tube-spacers.

Adrenergic beta-Agonists↗

A homemade modification of a spacer device for delivery of bronchodilator or steroid therapy in patients with tracheostomies.

Patients who have artificial airways and who concurrently suffer with chronic obstructive airways disease encounter problems when administering inhaled bronchodilator and corticosteroid drugs via the tracheostomy. This is because most the devices are designed to deliver the metered dose of inhaled drugs via the oropharyngeal route and it is impossible to obtain an airtight seal from the inhaler device mouthpiece to the tracheostomy tube. The author describes a simple, effective and cheap modification of a spacer device designed by a creative patient to facilitate delivery of the aerosol via the tracheostomy tube to overcome this problem.

Adrenal Cortex Hormones↗

Comparison of nedocromil sodium and sodium cromoglycate administered by pressurized aerosol, with and without a spacer device in exercise-induced asthma in children.

To compare the effectiveness of nedocromil sodium (NS) and sodium cromoglycate (SCG) administered by metered dose inhaler (MDI) in preventing exercise-induced asthma (EIA), 12 asthmatic children with EIA were studied in a randomized, double-blind, cross-over, placebo-controlled study. NS and SCG were given by MDI alone, and by MDI with a 700 ml spacer device (Fisonair, Fisons, UK), in order to assess the benefit of using such a device. Following a baseline exercise challenge, the protective effect of NS, SCG or placebo was evaluated in each subject. The percentage fall in forced expiratory volume in one second, and percentage protection were measured. NS and SCG provided a significant and comparable protection from EIA, and both were better than placebo. No further improvement was observed after drug administration via the spacer. Both NS and SCG are effective in preventing EIA in children, when administered at the recommended clinical dose, and the use of a spacer for administering the drug provides no advantage if the technique of inhalation is good.

Administration, Inhalation↗

Comparison of twice daily administration of a new corticosteroid budesonide with beclomethasone dipropionate four times daily in the treatment of chronic asthma.

The efficacy and side-effects of a new corticosteroid aerosol, budesonide and beclomethasone dipropionate were assessed in 30 patients with chronic asthma in a double-blind cross-over study. Budesonide was administered, 200 micrograms twice daily, from a conventional pressurized aerosol with a tube spacer extension attached and beclomethasone was given via a conventional inhaler in the recommended four times daily dose of 100 micrograms, each treatment being administered for one month. No clinically significant differences were found between the two treatments and no significant side-effects were observed.

Adolescent↗

Methodological optimization of polyethylenimine (PEI)-based gene delivery to the lungs of mice via aerosol application.

BACKGROUND: Polyethylenimine (PEI) has been successfully used for gene delivery to the lungs of mice via aerosol application using a whole body nebulization device. In this report we optimized the design of such an aerosol device. METHODS: Aerosol devices were constructed as either serial inhalation apparatus or as a whole body nebulization chamber connected to an aerosol spacer placed in a horizontal or vertical position. PEI-based gene vectors were nebulized using a standard jet nebulizer and luciferase gene expression of various tissues was examined. RESULTS: Using a whole body aerosol device resulted in luciferase gene expression in the lungs of mice at the same level as compared with a serial inhalation apparatus. Whereas gene expression was enhanced in the presence of 5% CO(2)-in-air, anesthesia of mice strongly decreased gene expression even when mice were intubated with an intravascular cannula. Reduction of the median mass aerodynamic diameter (MMAD) of the aerosol from 3.4 to 0.27 microm by interposition of an aerosol spacer increased gene expression significantly 3-fold. Drying of the aerosol by silica gel additionally increased gene delivery significantly 3-fold. Reporter gene expression mediated by branched PEI 25 kDa was 9- and 15-fold higher as compared with linear PEIs of 22 and 25 kDa, respectively, and was dependent on the DNA concentration. Gene expression was detectable as soon as 6 h after gene vector application and reached a maximum after 72 h but was still detectable after 14 days. The presence of Zn(2+) did not increase gene expression. CONCLUSION: We propose aerosol drying as a novel and simple method of optimizing PEI-based gene delivery to the lungs.

Aerosols↗

Inhaled beta 2-agonist and positive expiratory pressure in bronchial asthma. Influence on airway resistance and functional residual capacity.

INTRODUCTION: Positive expiratory airway pressure seems to dilate narrowed or collapsed airways, but this may be accompanied by a maintained and harmful increase in resting lung volume in obstructive pulmonary disease. PURPOSE: To evaluate the influence of inhaled terbutaline and positive expiratory pressure (PEP) on airway resistance (Raw) and functional residual capacity (FRC) in bronchial asthma. DESIGN: Randomized crossover design, single blind with regard to inhaled medication, open with regard to PEP (PEP can be felt). MATERIAL AND METHODS: Ten patients with bronchial asthma inhaled placebo and terbutaline in doses of 0.125 mg, 0.5 mg, and 1.5 mg by cone spacer combined with a facemask giving 0, 10, or 15 cm H2O PEP on separate days. FRC and Raw were measured by body plethysmography before and after inhalations. Data were analyzed by analysis of variance with terbutaline dose and PEP as factor levels. RESULTS: The effect of terbutaline: Raw decreased significantly (p < 0.0001) after 0.125 mg and 1.5 mg. The FRC did not change significantly. The effect of PEP: Raw decreased, but significantly only when the dose of 1.5 mg terbutaline was excluded from the analysis. Raw decreased with PEP 10 and 15 cm H2O, mean 0.6 (95 percent CI: -1.1, -0.2) and 0.9 (95 percent CI: -1.3, -0.4) cm H2O/L/s. The FRC did not change significantly with the PEP level. CONCLUSION: PEP only had influence on Raw when insufficient doses of terbutaline were inhaled, whereas once an efficient dose of terbutaline was administered, significant bronchodilation was achieved with or without PEP. Positive expiratory pressure did not increase FRC.

Administration, Inhalation↗

Nebulizer possibilities and limitations.

The ban of chlorofluorocarbon (CFC) propellants in metered dose inhalers (MDIs) gives rise to many alternatives and innovations: 1. CFC substitution by non-CFC propellants in MDIs. 2. battery driven miniaturized mechanical and piezoelectric nebulizers 3. revitalization of hand driven pocket nebulizers 4. self actuated dry powder inhalers (DPI's). All devices can be used with or without spacers. The choice for solid or liquid particles, e.g. powder or droplet aerosols, will also depend on the drug properties and the availability on the market for aerosol use. The nebulizer device will be chosen according to the medical need (emergency or long term treatment), the technical alternatives available in different countries, the possibility of patient cooperation (children, severely ill patients), and last not least marketing strategies and costs. The bronchial circulation is an important distribution system for medicine deposited by aerosol routes in the lung.

Administration, Inhalation↗

[A questionnaire survey on the self-assessment to the asthmatic treatment in Saitama Prefecture: results from 2825 cases].

The aim of this study was to survey the self-assessment to the treatment of adult bronchial asthmatics in Saitama prefecture. A questionnaire on daily symptoms and medications was distributed to 2825 adult asthmatic subjects who were treated at 125 hospitals/clinics in Saitama prefecture between September 15th and October 30th 1998. More than half (52.7%) of patients described that their general condition of asthma was poorly controlled. Even among the patients described that their condition was good or fair, 30.2% of them had some asthmatic symptoms such as shortness of breath or nocturnal awakening. Although inhaled corticosteroids were used in 66.2%, the ratio of patients who used spacer and kept drug compliance as prescribed were 59.6% and 45.8%, respectively. According to the physician's reports, cysteinyl leukotriene antagonist was used in 35.7%, which was comparable to the total of another anti-allergic drugs (37.3%). These results suggest that more than half of asthmatic patients in Saitama prefecture were not satisfied with their conditions of the disease control. Furthermore, more thorough education on the technique and compliance of inhaled corticosteroids would be required.

Adolescent↗

[Comparative study of the acceptability of Tilade Syncroner and Tilade Standard by mildly asthmatic patients. Syncroner Trial Research Group].

An open multicenter randomized, cross over study has compared the patients acceptance and preference of nedocromil sodium delivered as metered dose inhaler (MDI) containing 112 puffs and attached to an open tube spacer, the Syncroner with the same product as MDI containing 56 puffs delivered through a standard mouthpiece adaptator. One hundred and forty four patients (67 males) suffering from moderate asthma (mean FEV1: 86%) aged 18 to 70 years received alternatively 2 puffs of 2 mg 4 times a day of nedocromil sodium either by Syncroner or by the standard adaptator for two weeks in random order. The acceptance of each device was assessed by a questionnaire after two weeks of treatment. At the end of the study, the preference was recorded globally by the mean of a visual analog scale and for each of the following criteria: tolerability, shape, efficacy, hygiene, easiness to use, cleaning, contents and confidence. After two weeks of treatment the Syncroner was as well accepted as the standard mouthpiece and even better in terms of contents, cleaning and confidence. At the end of the study, 50.4% of patients prefering the Syncroner and 49.6% the standard mouthpiece. Patients significantly favoured the Syncroner because of its contents, hygiene, and cleaning (p < 0.05 for these 3 criteria) and tolerability (p = 0.07). In conclusion, after two weeks of treatment, the Syncroner was as well accepted as the standard MDI, 50% of patients preferred the new inhalation device. Considering its interest as training aid and the better lung deposition, it can be proposed for drug delivery without risk of a rejection by patients.

Administration, Inhalation↗

Effect of detergent-coated versus non-coated spacers on bronchodilator response in children with asthma.

OBJECTIVE: Previous studies have demonstrated that coating spacers with ionic detergents minimizes the static charge and thereby improves in vivo drug deposition. The present study aims to examine the effect of coated spacers versus non-coated spacers in the clinical situation. METHODS: A randomized, double-blind study in children with asthma and a ratio of forced expiratory volume in 1 s to forced vital capacity (FEV1/FVC) of < or =72% predicted was carried out. Spirometry was performed at baseline and at 10 min and 20 min after inhalation of two puffs of salbutamol (100 microg/puff) through either a detergent-coated or a non-coated spacer. RESULTS: Fifty children were studied (mean age 11.6 years, range 7-18 years): 26 in the group using coated spacers (CG); and 24 in the group using non-coated spacers (NCG). The mean percentage change in FEV1 from baseline 10 min after inhalation was 18.8% (range 5-50%) in the CG versus 18.5% (range 3-35%) in the NCG. At 20 min after inhalation, the per cent increase in FEV1 was 19.8% (range 0-50%) in the CG versus 19.5% (range 9-35%) in the NCG. There was no significant difference between groups in the percentage change in FEV1 after 10 min (P = 0.91), or after 20 min (P = 0.93). CONCLUSIONS: There was no improvement in bronchodilatation from detergent-coated spacers in the present study, possibly because a maximal bronchodilator response was achieved with the lower output.

Adolescent↗

Teacher initiated improvement of asthma policy in schools.

OBJECTIVE: To assess whether information about asthma acquired by individual teachers, following attendance at an inservice seminar, would be communicated to other school staff, and whether policies about asthma management would be subsequently developed in schools. METHODOLOGY: A telephone interview was conducted of 50 primary school teachers in the Hunter Region who were selected randomly from those who had represented their school at an inservice seminar about asthma. RESULTS: All 48 respondents had provided feedback to their colleagues, mostly at a staff meeting. After the seminar the number of schools with a written policy about the management of asthma had increased from 1 to 20. Initially the school's first aid kits contained a bronchodilator inhaler in 25 schools (increasing to 43 after the seminar), a spacer device in six schools (increasing to 47) and written guidelines for management of an asthma attack in seven schools (increasing to 32). Teachers from four schools indicated that all school staff knew how to recognize an acute attack prior to the seminar compared with 22 schools afterwards. Before the seminar 18 schools asked parents to supply written instructions for the management of their children at school but this increased to 44 after the seminar. CONCLUSIONS: A programme of one-off seminars attended by one teacher from each primary school resulted in large increases in the proportion of schools with appropriate policies for the management of asthma in the school environment.

Asthma↗

Measured bronchodilator use in preschool children with asthma.

OBJECTIVE: To investigate how parents use bronchodilator treatment for relief of symptoms when treating their asthmatic preschool children. DESIGN: A commercial electromechanical timer device was attached to a large volume spacer to record the time and date of each use of inhaled bronchodilator over two months. The recorded time and dates were compared with symptoms noted in an asthma diary card. SETTING: Large paediatric teaching hospital in Glasgow. SUBJECTS: 29 preschool children with moderately severe asthma attending a specialist paediatric asthma clinic. MAIN OUTCOME MEASURES: Inhaler use measured by the timer device; symptoms and inhaler use recorded by parents in a daily asthma diary. RESULTS: Satisfactory data were obtained in 22 of the 29 children; the median number of study days was 53 (range 18-77). Asthmatic symptoms were recorded on a median of 30 (3-77) days. Bronchodilator was used on a median of 19 (2-73) days, or on 63% (7-100%) of days when symptoms occurred. The median number of puffs used in a day was 1 (range 0-100) and was significantly related to symptom severity in only 14 of the 22 children. In only two of the 22 children was bronchodilator given more frequently than four hourly, and only five children ever used more than 12 puffs a day. CONCLUSIONS: The frequency of parental administration of bronchodilator treatment was variable and not closely related to the parent's record of symptom severity. Parents often recorded symptoms in their children but did not treat them.

Asthma↗

The Blo-Bag, a disposable spacer.

" Blo -Bag", a new disposable spacer device, has been tested in conjunction with Duovent metered dose inhaler. Duovent produced a significant bronchodilatation for the duration of the study. When delivered by the " Blo -Bag" it produced a significantly greater increase in peak expiratory flow rate than when delivered by metered dose inhaler. There were no significant side effects.

Adult↗