Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

An acoustic wave biosensor for human low-density lipoprotein particles: construction of selective coatings.

Cholesterol is found in four major classes of blood particles including chylomicrons, very low-density lipoproteins (VLDL), low-density lipoproteins (LDL), and high-density lipoproteins (HDL). The most studied fraction is LDL as it is most closely associated with heart disease. The challenge in current methods of analysis is the determination of the cholesterol in the individual lipoprotein fractions. Accordingly, the critical step in any analysis is the complete separation of the lipoprotein fractions. In this work, enhanced selectivity for the LDL fraction was achieved by the covalent binding of dextran sulfate (DS) to the gold surface of a thickness shear-mode acoustic wave sensor. The thickness and surface concentration of the DS layer was estimated by in situ ellipsometry to be 219 A and 0.8 ng/mm(2), respectively, but it was difficult to construct the sensing layer reproducibly. The DS coated sensor was ten times more responsive to LDL than the other lipoprotein (LP) fractions. The sensor was a main component in a flow injection analysis system that exposed LDL, VLDL and HDL to not only the DS layer, but also to the underlayers used in the construction of the DS layer. A possible regeneration solution was found which would rinse the LDL from the layer, restoring the sensor for repeated use. Frequency shifts from LP absorption into the DS layer were corrected for dissipative losses through the DS layer using an oscillator circuit equipped with an automatic gain control feature.

Acoustics↗

Amperometric determination of laminarin using immobilized beta-1,3-glucanase.

A novel sensor system equipped with a reactor packed with beads containing immobilized beta-1,3-glucanase and glucose oxidase was developed for the amperometric determination of laminarin concentration. The proposed sensor system consisted of a reactor, an oxygen electrode, a flow cell, a pump, a buffer tank, and a recorder. The measurement was performed with a flow injection system. The optimum conditions for the sensor system were as follows: transfer solution, pH 7.0; 0.1 M phosphate buffer solution; flow rate, 0.15 ml/min; and sample volume, 50 microl. The response was correlated to the laminarin concentration. The calibration curve was obtained between 50 and 0.5 mg/ml laminarin (R2 = 0.994). The detection limit was 50 microg/ml laminarin (the ratio of signal/noise = 3). The relative standard deviations were 2.0% (n = 15) and 2.5% (n = 15) for 0.4 and 1.0 mg/ml laminarin solutions, respectively. One assay was completed within 5 min. Results suggest that the sensor can be used not only for the analysis of seaweed and health-enhancing foods but also for monitoring the initial pollution of the marine environment.

Biosensing Techniques↗

Analysis of the interactions of ribonuclease inhibitor with kanamycin.

The interaction of ribonuclease inhibitor (RI) with kanamycin was studied by molecular modeling. The preliminary binding model was constructed using the Affinity module of the Insight II molecular modeling program and the key residues involved in the combination of RI binding to kanamycin were determined. Meanwhile, we determined relevant surface characteristics determining the interaction behavior. The modeling results indicated that electrostatic interactions and H-bond forces may work as major factors for the molecular interaction between kanamycin and RI. The above results are useful for elucidating the molecular principles upon which the selectivity of a kanamycin is based. The quartz-crystal microbalance (QCM) is a new method usually used to monitor the binding function of macromolecules with samples online in a flow-injection analysis (FIA) system. The experimental results demonstrate that kanamycin has an extraordinary affinity to the basic protein RI, and our result is consistent with the molecular modeling results. These principles can in turn be used to study the molecular recognition mechanism and design a mimic of kanamycin for the development of new RI binders.

Binding Sites↗

The electrochemical oxidation of homocysteine at boron-doped diamond electrodes with application to HPLC amperometric detection.

The electrochemical oxidation of homocysteine was studied at as-deposited and anodized (oxidized) boron-doped diamond (BDD) thin film electrodes with cyclic voltammetry, flow injection analysis and high-pressure liquid chromatography with amperometric detection. At anodized boron-doped diamond electrodes, highly reproducible, well-defined cyclic voltammograms for homocysteine oxidation were obtained in acidic media, while as-deposited diamond did not provide a detectable signal. In alkaline media, however, the oxidation response was obtained both at as-deposited and anodized diamond electrodes. The potential sweep rate dependence of homocysteine oxidation (peak currents for 1 mM homocysteine linearly proportional to v(1/2), within the range of 0.01 to 0.3 V s(-1)) indicates that the oxidation involves a diffusing species, with negligible adsorption on the BDD surface at this concentration. In the flow system, BDD exhibited a highly reproducible amperometric response, with a peak variation less than 2%. An extremely low detection limit (1 nM) was obtained at 1.6 V vs. Ag/AgCl. In addition, the determination of homocysteine in a standard mixture with aminothiols and disulfide compounds by means of isocratic reverse-phase HPLC with amperometric detection at diamond electrodes has been investigated. The results showed excellent separation, with a detection limit of 1 pmol and a linear range of three orders of magnitude.

Boron↗

A flow injection kinase assay system based on time-resolved fluorescence resonance energy-transfer detection in the millisecond range.

A flow injection analysis (FIA) system for biochemical assays using time-resolved fluorescence resonance energy transfer (TR-FRET) in the millisecond time scale was developed. As a model system, we studied a kinase assay, measuring the phosphorylation of poly(GT)-biotin (substrate) by a receptor tyrosine kinase (epidermal growth factor receptor). A streptavidin labeled with XL665 (SA-XL665)-the acceptor-was coupled to the biotin moiety, and an antiphosphotyrosine antibody labeled with europium cryptate (Ab-EuK)-the donor-was coupled to the phosphorylated tyrosine group(s). Long-lived FRET can only occur if the substrate is successfully phosphorylated. For the time-resolved detection of such long-lived luminescence phenomena in a flow system, the repetition rate of the excitation source plays a crucial role. Good results were obtained for a small-sized commercially available quadrupled Nd:YAG laser emitting at 266 nm with a repetition rate of 7.8 kHz and a pulse width of 0.3 ns. The long-lived emissions of the donor at 625 nm and that of the acceptor at 665 nm were monitored simultaneously with two photomultipliers, using a delay time of 50 micros and a gate time of 75 micros to exclude background fluorescence interferences. In the FIA experiments, the Ab-EuK concentration was 6 nM and the substrate concentration and SA-XL665 concentrations were 7 nM. By monitoring the intensity changes at 625 and 665 nm, the inhibition of tyrosine kinase by tyrphostin AG1478 was studied and an IC(50) value of 5.1 +/- 0.4 nM obtained.

Binding Sites↗

Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides.

This report describes the development of novel sonochemically fabricated, bioengineered acetylcholinesterase and polyaniline carbon/cobalt phthalocyanine biosensors for the ultra-sensitive determination of a number of different pesticides. Arrays of this type typically have population micro-electrode densities of up to approximately 2 x 10(5) cm(-2); these represent the highest micro-electrode population densities reported to date by any fabrication means. The enzymatic response of the sensors is inhibited upon incubation with the pesticide, and we have shown that Dichlorvos, Parathion and Azinphos may be determined down to concentrations of approximately 1 x 10(-17) M, approximately 1 x 10(-16) M and approximately 1 x 10(-16) M, respectively. These lower limits of detection are lower than otherwise achievable by any other analytical approach. Measurements were performed within a custom built flow injection system that operates at a constant flow of 1 ml min(-1). Sensor stability studies were also performed whereby a stabilizer mixture of sucrose and polygalacturonic acid was added to the immobilised enzyme matrix at the working electrode and left to dry. Sixty-five percent of the initial enzyme activity was found to remain after a period of 92 days to allow storage of these electrodes and facilitating transportation if required.

Acetylcholinesterase↗

Electrogenerated chemiluminescence of luminol for oxidase-based fibre-optic biosensors.

The luminol electrochemiluminescence has been exploited for the development of several fibre-optic biosensors allowing the detection of hydrogen peroxide and of substrates of H(2)O(2)-producing oxidases. Electro-optical flow injection analysis of glucose, lactate, cholesterol and choline are thus described. To perform the experiments, a glassy carbon electrode was polarized at a fixed potential. Luminol was then electrochemically oxidized and could react in the presence of hydrogen peroxide to produce light. Several parameters had to be optimized to obtain reliable optical biosensors. An optimum applied potential of +425 mV between the glassy carbon electrode and the platinum pseudo-reference electrode was determined, allowing the best signal: noise ratio to be obtained. It was also necessary to optimize the experimental conditions for the immobilization of the different oxidases involved (preactivated membranes, chemically activated collagen membranes, photopolymerized matrix). For each biosensor developed, the optimum reaction conditions have been studied: buffer composition, pH, temperature, flow rate and luminol concentration. Under optimal conditions, the detection limits (S/N = 3) were 30 pmol, 60 pmol, 0.6 nmol and 10 pmol for lactate, glucose, cholesterol and choline, respectively. The miniaturization of electrochemiluminescence-based biosensors has been realized using screen-printed electrodes instead of a glassy carbon macroelectrode, with choline oxidase as a model H(2)O(2)-generating oxidase.

Alcohol Oxidoreductases↗

Optimization of enzyme ratios in a coimmobilized enzyme reactor for the analysis of D-xylose and D-xylulose in a flow system.

A coupled enzyme system for the detection of D-xylose and D-xylulose is presented. The system is based on three consecutive enzymatic steps. The enzymes xylose isomerase (XI), mutarotase (MT), and glucose dehydrogenase (GDH) are coimmobilized on controlled pore glass and packed in a bed reactor. The relative amount of enzymes, i.e., enzyme ratio, plays a critical role in driving the overall reaction, resulting in a system with linear response characteristics and an operational range of several orders of magnitude. Three different enzyme ratios are assayed to achieve maximum conversion efficiencies for xylose and xylulose. The highest enzyme unit ratio assayed, 13.4 of GDH to XI, gave the highest apparent pseudo-first-order rate constant showing the importance of the last enzymatic reaction in the coupled system to make the overall reaction thermodynamically favorable. A pH of 7.0 was found to be an optimum compromise for the multienzyme system. Sensitivity was dependent on NAD+ concentration. The study was carried out in a flow injection system. The optimized reactor has been applied for the catalytic detection of pentoses in flow injection analysis (FIA) and liquid chromatography (LC).

Aldose-Ketose Isomerases↗

Application of high-surface-area ZrO2 in preconcentration and determination of 18 elements by on-line flow injection with inductively coupled plasma atomic emission spectrometry.

A flow-injection analysis (FIA) system incorporating a micro-column of ZrO2 has been used for the development of an on-line multi-element method for the simultaneous preconcentration and determination of Al, Bi, Cd, Co, Cr, Cu, Fe, Ga, In, Mn, Mo, Ni, Pb, Tl, V, Sb, Sn, and Zn by inductively coupled plasma atomic emission spectrometry (ICP-AES). The conditions for quantitative and reproducible preconcentration, elution, and subsequent on-line ICP-AES determination were established. A sample (pH 8) is pumped through the column at 3 mL min(-1) and sequentially eluted directly into the ICP-AES with 3 mol L(-1) HNO3. With a sample volume of 100 mL and an elution volume of 1 mL signal enhancement 100 times better than for conventional continuous aspirating systems was obtained for the elements studied. The reproducibility (RSD %) of the method at the 10 ng mL(-1) level in the eluate is acceptable - less than 8% for five replicates. Recoveries between 95.4% and 99.9% were obtained for the elements analysed. ZrO2, with a specific surface area of 57 m2 g(-1) and a capacity of approximately 5 mg g(-1) for the elements studied, was synthesized by hydrolysis of ZrCl4. The preconcentration system was evaluated for several simple synthetic matrices, standard water samples and synthetic seawater. The effect of foreign ions on the efficiency of preconcentration of the elements studied was investigated. The application of a micro-column filled with high-surface-area ZrO2 and flow injection inductively coupled plasma atomic emission spectrometry enables preconcentration and simultaneous determination of 18 elements at low concentrations (ng L(-1)) in different water samples.

Chlorides↗

Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection.

A microchip-based enzyme-linked immunosorbent assay (microELISA) system was developed and interferon-gamma was successfully determined. The system was composed of a microchip with a Y-shaped microchannel and a dam structure, polystyrene microbeads, and a thermal lens microscope (TLM). All reactions required for the immunoassay were done in the microchannel by successive introduction of a sample and regents. The enzyme reaction product, in a liquid phase, was detected downstream in the channel using the TLM as substrate solution was injected. The antigen-antibody reaction time was shortened by the microchip integration. The limit of the determination was improved by adopting the enzyme label. Moreover, detection procedures were greatly simplified and required time for the detection was significantly cut. The system has good potential to be developed as a small and automated high throughput analyzer.

Enzyme-Linked Immunosorbent Assay↗

Sample flow switching techniques on microfluidic chips.

This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.

Biosensing Techniques↗

Environmental water monitoring by capillary electrophoresis and result comparison with solvent chemistry techniques.

The aim of this work was to determine inorganic ions from natural waters by capillary electrophoresis (CE) and to compare the results obtained with those measured with conventional solvent chemistry techniques. The project was part of a larger CE study, during which we measured inorganic ions from some lake and river systems and groundwaters in Southern Finland. Results obtained from contaminated Finnish waters were compared with samples from the River Rhine in the Düsseldorf area. Two CE methods were used for analysis: one for determination of chloride, sulfate, nitrite and nitrate at pH 7.7 and the other for ammonium, potassium, calcium, sodium and magnesium at pH 3.6, both methods using identification based on indirect UV detection. Two separation methods were used in order to prevent complex formation of metals with sulfate, hydroxide and decomposed organic matter present in the environmental samples. On the basis of the CE studies dilution was needed for those samples having more than 100 mg/l of sulfate, chloride, calcium and sodium. On average, the natural waters in the study contained ammonium, magnesium, sodium, potassium and calcium below 0.3, 20, 200, 20, and 200 mg/l, respectively. The concentrations of chloride, sulfate, nitrite and nitrate were below 20, 100, 10, and 10 mg/l, respectively. Correlation of the CE results with those acquired by titration, atomic absorption spectrometry, ion chromatography and flow injection analysis were obtained; R2 values for the comparison tests varied from 0.8816 to 0.9994 depending on the ion. The repeatabilities of the anion and cation CE methods were tested using laboratory-made reference sample mixtures with high and low salt concentration.

Calibration↗

On-line collection/concentration and detection of sulfur dioxide in air by flow-injection spectrophotometry coupled with a chromatomembrane cell.

A simple and rapid procedure for SO2 determination in air was developed by using a flow injection analysis (FIA) system coupled with a 3-hole chromatomembrane cell (CMC). The CMC was applied for the on-line collection/concentration of SO2 from air into a solution of 2 g l(-1) triethanolamine (TEA) solution as an absorbing solution: SO2 was converted to SO3(2-) in the alkaline absorbing solution. The solution containing absorbed SO2 was introduced into the carrier stream of the FIA system. The amount of SO3(2-) in the absorbing solution was measured by spectrophotometry with a mixed reagent of pararosaniline and formaldehyde, and was converted to the concentration of SO2 in the air sample. A calibration graph prepared by using standard sodium sulfite aqueous solutions was adopted for the determination of SO3(2-) in the absorbing solution. The SO2 concentration in indoor air examined was found to be 22.7 +/- 0.2 ppbv using 20 ml of air sample with the air flow rate of 5 ml min(-1), where the relative standard deviation was 1.7%. The detection limit for aqueous solutions and air samples were 6.9 x 10(-8) M and 0.48 ppbv, respectively. The measuring time for one sample was about 10 min when a 20 ml air sample was used. The interferences from common anionic species, formaldehyde and acetaldehyde, were also examined.

Journal Article↗

High resolution screening of plant natural product extracts for estrogen receptor alpha and beta binding activity using an online HPLC-MS biochemical detection system.

A new screening technology that combines biochemical analysis with the resolution power of high-performance liquid chromatography (HPLC), referred to here as high-resolution screening (HRS) technique, is described. The capability of the HRS technology to analyze biologically active compounds in complex mixtures is demonstrated by screening a plant natural product extract library for estrogen receptor (ER) alpha and beta binding activity. The simultaneous structure elucidation of biologically active components in crude extracts was achieved by operating the HRS system in combination with mass spectrometry (MS). In contrast to conventional microtiter-type bioassays, the interactions of the extracts with the ER and the employed label, coumestrol, proceeded at high speed in a closed, continuous-flow reaction detection system, which was coupled directly to the outlet of a HPLC separation column. The reaction products of this homogeneous fluorescence enhancement-type assay were detected online using a flowthrough fluorescence detector. Primary screening of the extract library was performed in the fast-flow injection analysis mode (FlowScreening) wherein the chromatographic separation system was bypassed. The library was screened at high speed, using two assay lines in parallel. A total of 98% of the identified hits were confirmed in a traditional 96-well microplate-based fluorescence polarization assay, indicating the reliability of the FlowScreening process. Active extracts were reassayed in a transcriptional activation assay in order to assess the functional activity of the bioactive extracts. Only functional active extracts were processed in the more time-consuming HRS mode, which was operated in combination with MS. Information on the number of active compounds, their retention times, the molecular masses, and the MS/MS-fingerprints as a function of their biological activity was obtained from 50% of the functional active extracts in real time. This dramatically enhances the speed of biologically active compound characterization in natural product extracts compared to traditional fractionation approaches.

Biological Factors↗

Mode of action and subsite studies of the guluronan block-forming mannuronan C-5 epimerases AlgE1 and AlgE6.

AlgE1, AlgE5 and AlgE6 are members of a family of mannuronan C-5 epimerases encoded by the bacterium Azotobacter vinelandii, and are active in the biosynthesis of alginate, where they catalyse the post-polymerization conversion of beta-D-mannuronic acid (M) residues into alpha-L-guluronic acid residues (G). All enzymes show preference for introducing G-residues neighbouring a pre-existing G. They also have the capacity to convert single M residues flanked by G, thus 'condensing' G-blocks to form almost homopolymeric guluronan. Analysis of the length and distribution of G-blocks based on specific enzyme degradation combined with size-exclusion chromatography, electrospray ionization MS, HPAEC-PAD (high-performance anion-exchange chromatography and pulsed amperometric detection), MALDI (matrix-assisted laser-desorption ionization)-MS and NMR revealed large differences in block length and distribution generated by AlgE1 and AlgE6, probably reflecting their different degree of processivity. When acting on polyMG as substrates, AlgE1 initially forms only long homopolymeric G-blocks >50, while AlgE6 gives shorter blocks with a broader block size distribution. Analyses of the AlgE1 and AlgE6 subsite specificities by the same methodology showed that a mannuronan octamer and heptamer respectively were the minimum substrate chain lengths needed to accommodate enzyme activities. The fourth M residue from the non-reducing end is epimerized first by both enzymes. When acting on MG-oligomers, AlgE1 needed a decamer while AlgE6 an octamer to accommodate activity. By performing FIA (flow injection analysis)-MS on the lyase digests of epimerized and standard MG-oligomers, the M residue in position 5 from the non-reducing end was preferentially attacked by both enzymes, creating an MGMGGG-sequence (underlined and boldface indicate the epimerized residue).

Azotobacter vinelandii↗

Enantiomeric separation and quantification of pindolol in human plasma by chiral liquid chromatography/tandem mass spectrometry using staggered injection with a CTC Trio Valve system.

Pindolol is a non-selective beta-adrenergic antagonist (beta-blocker) for the treatment of cardiovascular diseases such as hypertension and angina pectoris. It has one chiral center, and, therefore, two optical isomers. It was essential to develop an enantioselective assay to measure each enantiomer in human plasma. However, separation of enantiomers using chiral chromatography usually requires relatively long retention times. This can pose a problem for rapid turnaround of a large number of samples (i.e., clinical studies). In the present study, a simple and sensitive chiral liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for the determination of S-(-)- and R-(+)-pindolol in human plasma. To increase throughput, staggered sample injection was employed using a CTC Trio Valve system on a CTC HTS PAL autosampler. The method exhibited good intra- and inter-day accuracy and precision, and was linear over a dynamic range of 250 pg/mL to 250 ng/mL for each pindolol enantiomer. Intra- and inter-day accuracy ranged between 90.0-106% and 91.6-104% for both quality control (QC) samples of S-(-)- and R-(+)-pindolol, respectively. The respective intra- and inter-day precision ranged between 4.24-7.86% and 4.98-10.4%.

Blood Chemical Analysis↗

Miniaturized one-chip electrochemical sensing device integrated with a dialysis membrane and double thin-layer flow channels for measuring blood samples.

We have developed a microfluidic device consisting of a gold film working electrode modified with lactate oxidase and Os-poly(vinylpyridine) mediator containing horseradish peroxide, and reference and counter electrodes in a microflow detection channel separated by a microdialysis membrane from another microflow channel used for sample injection. The dialysis membrane is cellulose with a molecular weight cut off of 10 kDa. We achieved control over a wide recovery rate range of 3-94% because the device is capable of controlling both flow rates in the dual thin-layer channels. We were able to measure the lactate concentration in blood samples within a few minutes without any pretreatment because biomolecules are simultaneously separated by molecular weight and detected in the device. We achieved quantitative and reproducible measurements of the lactate concentration in blood samples, and obtained a relative standard deviation of 1.5% (n = 8). With our device, the lactate concentration in dog whole blood was measured with high stability without any pretreatment.

Animals↗

Study on multiple-enzyme electrode for sucrose determination.

Invertase (INV), mutarotase (MUT), glucose oxidase (GOD) and BSA were coimmobilized via glutaraldehyde-bridged covalent bonding, and directly absorbed on the teflon membrane. This membrane was covered with a nylon mesh and placed over an oxygen electrode. An enzyme electrode for flow injection analysis system (EFIA) was adopted. The optimum enzyme composition (IU) for immobilization on the teflon membrane of INV-MUT-GOD was found to be in the ratio 72:48:2.4, with a recovery activity INV-MUT of more than 42.9%. pH 5.8-6.5 was the most suitable range of acidity for the sensor activity. The optimum temperature was 35-45 degrees C. The system exhibited good linearity in the range of 5 x 10(-4) approximately 10(-1) M sucrose (kinetic method) and 10(-5) approximately 2 x 10(-3) M sucrose (steady state method), in short response time (20 seconds for kinetic method, 2 minutes for steady state method), CV = 1.7% (kinetic method). The sensor had been used for determining sucrose concentration in fermentation broth, with an average recovery rate of 98%. The interference caused by the presence of glucose derived from decomposition of sucrose was eliminated by calibration with a GOD sensor. No significant loss of the enzyme electrode activity was observed after 120 hours of the continuous flow of fresh 1 mM sucrose. The multiple-enzyme membrane showed a relatively long lifetime (compared with 14 hours as reported previously) and good storage stability (30 days, stored in distilled water at 4 degrees C).

Biosensing Techniques↗