[Experiences with Lugol's solution in flocculation reaction].
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In this study, polyamine flocculants were synthesized and applied to Nak-dong river raw water in Korea to examine their efficiency in reducing turbidity, total organic carbon (TOC) and UV254. Synthesized polyamines were effective as flocculants for water treatment and the addition of organic polymer caused a reduction of 50-80% of the consumption of polyaluminium chloride (PAC). The effects of polyamine on the removal of turbidity, TOC and UV254 were investigated via both jar and pilot tests. The adsorption and separation mechanisms for the removal of turbidity and TOC by using the polymer flocculants were also observed.
Ten chitosan preparations with different molecular weights (MW) and degrees of deacetylation (DD) were tested for coagulation of 5 g L(-1) bentonite suspensions at pH 5 and 7 in demineralized water (DW) and in tap water (TW). Coagulation was better in TW than in DW for every condition and lower doses of chitosan were required at pH 5 than at pH 7. More than 95% of residual turbidity (after sedimentation in the absence of chitosan) was removed using less than 0.10 mg L(-1) chitosan in either TW or DW at pH 5 or in TW at pH 7. Higher doses were required for removal of turbidity in DW at pH 7, but in all cases the effective concentrations of chitosan were much lower than required for complete neutralization of the negative charge on the bentonite particles. Removal of turbidity was best for the higher MW chitosans in either the B series (89.5% DD) or the C series (95% DD) of chitosans. Overall, the results were consistent with destabilization of bentonite by the combined mechanisms of electrostatic patch and bridging. The improved performance of chitosan in TW could have been due to improved attachment to bentonite due to the presence of sulfate and other counter-ions in TW.
Copolymer of acrylamide and 2-[(methacryloyloxy)ethyl]trimethylammonium chloride [P(AM-DMC)] is found to be effective to combine anionic dyes with strong aqueous solubility. This work aims mainly at revealing the interaction between anionic dyes and [P(AM-DMC)] by running jar test, spectra analysis and equilibrium dialysis experiments. The results show that P(AM-DMC) effectively decolorizes the tested strong water soluble anionic dyes, such as acidic, reactive and direct dyes, from their aqueous solutions under mild acidic and neutral conditions. Higher cationicity and optimal dose of flocculant P(AM-DMC) have to be used to achieve satisfactory and effective decolorization. Comparison of IR spectra of dye, flocculant P(AM-DMC) and the floc formed indicates chemical interaction occurred between sulfonic groups of dye and quaternary ammonium of flocculant. Plots of r-logC suggest cooperative interaction exists evidently for some dyes tested. Addition of KCl or urea reduces binding extent evidently, which shows the importance of electrostatic and hydrophobic interaction. Therefore the interaction between dyes tested and P(AM-DMC) might be controlled by hydrophobic, cooperative interaction and energetic interaction which includes chemical and electrostatic interactions.
The need for a reference cholera antitoxin to serve as a standard for the calibration of cholera enterotoxin and toxoid as well as for measurement of the antitoxin response in animals and patients was recognized by the NIH Cholera Advisory Committee, NIAID, DHEW, USA. Two cholera antitoxins have been used for several years as provisional references, but neither was considered to embody all of the properties of an ideal standard. Accordingly, a lot of cholera antitoxin was prepared by immunization of goats with a formalinized, highly purified cholera toxin adsorbed on aluminum phosphate adjuvant. Booster injections were given at 8, 16 and 24 weeks. Plasma samples obtained from the 25 to 27 week bleedings were converted to serum, pooled, and freeze-dried. This serum possessed both high and constant toxin neutralizing activity in rabbit skin, rabbit ileal segment, mice, Y-1 adrenal cells and Chinese hamster ovary cells, and had high avidity by the rabbit skin assay. Hemagglutination tests gave identical values. It was shown to be highly specific by gel diffusion, but flocculation was relatively poor. On the basis of specificity, high avidity and toxin-neutralizing capacity this goat antitoxin (NIH Lot 1) was considered superior to previous provisional standards and is proposed as a satisfactory standard reference reagent.
This work shows an evaluation of treatments for the leachate produced at the Gramacho Municipal Landfill in Rio de Janeiro state, Brazil. This leachate has very peculiar characteristics, with a high salinity level and very low biodegradability (BOD(5)/COD of 0.05). A sequence of processes was employed in the treatment of this leachate. Initially, a physicochemical treatment was used, while the second stage consisted of application of ozone to improve the biodegradability of the leachate. The final stage comprised a biological treatment. The physical-chemical treatment led to COD and DOC removal levels of 40 and 25%, respectively, with the use of Al(2)(SO(4))(3). The sequence of treatments proposed brought good results, with an increase in the BOD(5)/COD ratio from 0.05 to 0.3 after ozonation. The toxicity tests performed using Brachydanio rerio and Poecilia vivipara showed that the toxicity of the leachate had hardly been reduced by ozonation. These results are in agreement with the fact that, despite the higher BOD(5)/COD ratio, the biological process did not present a good performance. The total average removal levels of COD and DOC achieved using the combined treatment were 73 and 63%, respectively, for an ozone dose of 3.0 gL(-1) by the leachate.
In the context of the development of treatment plant control techniques, three measures for maintaining a high efficiency of treatment plants during rainfall events were tested. The three measures are increasing the nitrification volume by operating a facultative aeration, bypassing the primary sedimentation and adding flocculants before secondary sedimentation. Ammonia concentrations and ammonia loads were used in combination with rainfall forecasts as the criteria for putting the measures into operation. A simulation based on the Activated Sludge Model No. 1 and a pilot scale plant were used for testing the measures. The results show that all three measures may be suitable to cope with peak loads of treatment plants during rainfall events.
The formulation of plasmid DNA on 100 nm gold nanoparticles surface-tethered via cationic dendrons, and the behaviour of the complex in cell culture media, is described in this communication. Adsorption of dendrons onto gold nanoparticles in water resulted in the generation of positively charged nanoparticles with a corresponding small increase in particle size. Addition of plasmid DNA did not markedly reduce the surface potential but resulted in a approximately 10-20% increase in hydrodynamic diameter. More dramatic effects were seen in the presence of cell culture media that, overall, drastically increased the apparent size of the gold-dendron-DNA nanoparticles and reduced the surface potential of the colloids, the presence of serum components partially ameliorating these effects possibly due to steric stabilisation. Release of the surface-tethered DNA was reduced in cell culture media compared to water. This reduced detachment of DNA coupled with the flocculation of the carrier which would likely inhibit endocytosis, demonstrates the importance of testing drug delivery systems with relevant physiologically based fluids prior to their use in vivo studies.
Six laboratories actively involved in water virology research participated in a methods evaluation study, conducted under the auspices of the American Society for Testing and Materials Committee on Viruses in the Aquatic Environment, Task Force on Drinking Water. Each participant was asked to examine the Viradel (virus adsorption-elution) method with cartridge-type Filterite filters for virus adsorption and organic flocculation and aluminum hydroxide-hydroextraction for reconcentration. Virus was adsorbed to filter media at pH 3.5 and eluted with either glycine buffer (pH 10.5) or beef extract-glycine (pHG 9.0). Considerable variation was noted in the quantity of virus recovered from four 100-liter samples of dechlorinated tapwater seeded with low (350 to 860 PFU) and high (1,837 to 4,689 PFU) doses of poliovirus type 1. To have a more uniform standard of comparison, all the test samples were reassayed in one laboratory, where titers were also determined for the virus seed. Test results of the Viradel-organic flocculation method indicated that the average percentage of virus recovery for low-input experiments was 66%, with a range of 8 to 20% in two laboratories, 49 to 63% in three laboratories, and 198% in one laboratory. For the high-input experiments, two laboratories reported recoveries of 6 to 12%, and four laboratories reported recoveries of 26 to 46%. For the Viradel aluminum hydroxide-hydroextraction procedure, two laboratories recovered 9 to 11%, whereas four obtained 17 to 34% for low-input experiments. For the high-input tests, two laboratories reported a recovery of 3 to 5%, and four recovered 11 to 18% of the seeded virus.(ABSTRACT TRUNCATED AT 250 WORDS)
This work examined how adding one of three polyelectrolyte flocculants (T3052: cationic, T2000: non-ionic, and T1052: anionic) affected the anaerobic digestion of wastewater sludge. Methane production, floc characteristics (morphology and zeta-potential) and process parameters (soluble chemical oxygen demands (SCODs) and reductive potentials) were monitored along the digestion tests. The digestion rates of T2000- and T1052-conditioned sludge resembled that for original sludge. The T3052-flocculated sludge generated methane at a higher rate during the first 6 days of digestion than did the original one. In the following stage, the digestion rate of sludge flocculated with T3052 at dosage exceeding 15 g/kg dried solids declined. For example, at 40 days of digestion the methane production amounts for original, 15 g/kg DS flocculated, and 40 g/kg flocculated sludge were of 136, 105, and 85 g/kg DS, respectively. The role of flocculants could change in different stages of digestion. The dosed polymers had no apparent toxicity to the inoculum used. The changes in SCOD, adenosintriphosphate concentrations, oxidative and reductive potential, and zeta-potentials did not correlate with the noted hindered digestion for T3052-conditioned sludge. Microphotographic observation revealed that the flocs of T3052-conditioned sludge were not only of a large size, but also were resistant to structural deterioration during digestion. Therefore, mass transfer resistance was proposed to account for the hindered digestion efficiency observed for T3052-conditioned sludge.
This study was designed to improve the removal efficiency of COD, SS, and microorganism at the S. Giovanni a Teduccio municipal wastewater treatment plant, Naples, Italy. The plant consists of screen, sand grinder, oil removal, coagulation, flocculation and sedimentation units, hypochlorite disinfection, mechanical dewatering, and thermal sludge conditioning. A series of Jar-test was conducted on twelve samples taken after screen using FeSO4 alone or together with Ca(OH)2 at 100 rpm rapid mixing for 1 min, 30 rpm for slow mixing for 20 min and 30 min for settling. 150 mg L(-1) and 450 mg/L doses of FeSO4 were used at a pH interval in between 6 and 9. The removals of COD, TSS, Escherichia coli and total coliforms were measured ranging from 40 to 70%, 70 to 90%, 96 to 99% and 97 to 99%, respectively when FeSO4 was used alone at 150 mg L(-1) and 450 mg L(-1) doses and at pH 6, 7 and 8. Wastewater discharge standards could be safely obtained at 150 mg L(-1) dose of FeSO4 with the use of 220 mg L(-1) Ca(OH)2 at pH 8 in terms of COD and E. coli removals resulted in 65% and 98%, respectively, with less sludge production to be disposed. Additionally, none of influent and supernatant samples tested in this study was found to be acute toxic on 24h-born Daphnia magna at 50% dilution.
The pretreatment of wastewater from a large-scale bakery was studied. In the coagulation-flocculation reaction, it was found that both alum and FeCl3 were effective in the jar tests. When at coagulant dosage of 90 to 100 mg/l, 55% of COD and 95 to 100% of SS could be removed. The optimum pH was at 6.0. In addition, the removal of SS was affected by pH more significantly, while the removal of COD was not affected in the pH range of 6.0 to 8.0. In the DAF experiments, 48.6% of COD and 69.8% of SS were removed in 10 min at a pressure of 4 kg/cm2, recycle ratio of 0.3 l/min, and pH of 6.0. Upon the addition of 100 mg/l of alum, the removal efficiency of COD did not increase while SS removal increased to 82.1%. It was found that 5-min flocculation time did improve the COD removal while it had little effect on SS removal. Flocculation for longer than 5 min did not enhance the flotation performance. Similar phenomena were observed when FeCl3 was used as the coagulant, except that flocculation had an insignificant effect on COD and SS removal. It was also found that FeCl3 was relatively more effective than alum. In summary, both coagulation-flocculation and DAF were efficient for the pretreatment. The advantages and disadvantages were discussed.
Johnson, H. M. (Robert A. Taft Sanitary Engineering Center, Cincinnati, Ohio), K. Brenner, R. Angelotti, and H. E. Hall. Serological studies of types A, B, and E botulinal toxins by passive hemagglutination and bentonite flocculation. J. Bacteriol. 91:967-974. 1966.-Formalinized sheep red blood cells (SRBC), sensitized with types A, B, and E botulinal toxoids and toxins by bis-diazotized benzidine (BDB), were tested against A, B, and E antitoxins prepared in horses and rabbits. Type B antitoxin cross-reacted with A toxoid SRBC, but the reciprocal cross-reaction was not observed. E toxin SRBC were specifically agglutinated by E antitoxin. Flocculation of antigen-sensitized bentonite particles was less sensitive in titration of antitoxin than hemagglutination. Also, reciprocal cross-reactions were observed between types A and B antitoxins. Cross-reactions in both serological tests were eliminated by titration of antitoxins in the presence of the heterologous antigens, with no inhibitory effect on the homologous antitoxins. Generally, equine antitoxins were less suitable for agglutinations, especially of antigen-sensitized bentonite particles. Types A, B, and E antitoxins were specifically inhibited by 43, 39, and 245 mouse ld(50) of their respective homologous toxins in the hemagglutination-inhibition test. A, B, and E antitoxins were specifically inhibited by 500, 950, and 1,500 mouse ld(50) of their respective homologous toxins in bentonite flocculation inhibitions. Formalinized SRBC sensitized with rabbit types A and B antitoxins by BDB were respectively clumped by as little as 0.75 to 1.3 mouse ld(50) of A toxin and 2.3 ld(50) of B toxin, whereas bentonite particles sensitized by the same antitoxins were specifically clumped by 150 ld(50) of A toxin and 630 ld(50) of B toxin. E antitoxin sensitization of SRBC or bentonite particles was not successful. Evidence is presented that indicates that the serological procedures are applicable to the detection of botulinal toxins in food.