Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capnography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Perioperative management and monitoring in anaesthesia.

In recent years, several risk factors for adverse outcome in patients undergoing anaesthesia have been identified. Besides human errors, cardiovascular and respiratory complications are associated with substantial morbidity. Assessment of complications has promoted the introduction of basic physiological monitoring in clinical practice. Whether monitoring directly affects outcome is not proven; however, circumstantial evidence suggests that basic cardiorespiratory monitoring decreases the incidence of serious accidents. Prevention of hypothermia also reduces anaesthesia-related morbidity. Measurement of body temperature is mandatory, and active warming is a simple, effective technique to avoid hypothermia. Evidence is growing that patients with known or suspected coronary artery disease should be treated with beta blockers perioperatively. Whether the type of anaesthesia-ie, general or regional-is relevant to perioperative mortality remains unclear. In subgroups of patients at high risk, neuraxial anaesthesia reduces the rate of respiratory and cardiovascular complications.

Adrenergic beta-Antagonists↗

Inspired and expired gas concentrations in man during carbogen breathing.

Capnometer measurements during 46 evaluable treatments in which patients were administered carbogen (95% O2, 5% CO2) have demonstrated that the mean inspired carbon dioxide level was 3.1% (range 0-4.7) and the mean inspired oxygen concentration was 70.6% (range 26.4-94). The explanation for this observation is leakage of air into the breathing system during radiotherapy.

Capnography↗

Causes of respiratory failure.

There are many causes of respiratory failure in veterinary patients. Assessment of oxygenation is imperative for the diagnosis and monitoring of these patients. Oxygen therapy should be instituted when hypoxemia is diagnosed to prevent tissue hypoxia, end-organ damage, and death. Methods of administering oxygen include commercial oxygen cages, mask oxygen, nasal cannulation (for dogs), and intubation. Mechanical ventilation is an option in many referral hospitals for patients who are severely hypoxemic and are not responding to inspired oxygen concentrations achieved with other methods of oxygen administration. One rule of thumb used to assess need for mechanical ventilation is a PaO2 of less than 50 mm Hg despite aggressive oxygen therapy, or a PaCO2 of greater than 50 mm Hg despite treatment for causes of hypoventilation. A mechanical ventilator has the ability to vary the FiO2 by increments of one, from 21% to 100% (0.21-1) oxygen in inspired gas. Positive end-expiratory pressure (PEEP) is also available on most ventilators. PEEP allows the alveoli to remain open on expiration, allowing gas exchange to occur in both inspiration and expiration. PEEP also helps diseased alveoli to inflate, increasing the available surface area for gas exchange and improving arterial blood oxygen tension. Because patients requiring mechanical ventilation have severe respiratory failure that did not respond to conventional oxygen therapy, the prognosis is guarded for most of these patients unless ventilation is instituted due to primary hypoventilation and lung parenchyma is normal. Hypoxemia caused by respiratory failure is a common problem in small animal veterinary patients. Assessment of blood oxygenation and continual monitoring of respiratory rate and effort are essential in management of these patients. Oxygen therapy should be instituted if hypoxemia is diagnosed. The prognosis depends on the underlying disease process and response to treatment with an enriched oxygen environment.

Animals↗

Utility of the expiratory capnogram in the assessment of bronchospasm.

STUDY OBJECTIVE: To determine whether the plateau phase of the expiratory capnogram (dco2/dt) can detect bronchospasm in adult asthma patients in the emergency department and to assess the correlation between dco2/dt and the peak expiratory flow rate (PEFR) in spontaneously breathing patients with asthma and in normal, healthy volunteers. METHODS: We carried out a prospective, blinded study in a university hospital ED. Twenty adults (12 women) with acute asthma and 28 normal adult volunteers (15 women) breathed through the sampling probe of an end-tidal CO2 monitor, and the expired CO2 waveform was recorded. The dco2/dt of the plateau (alveolar) phase for five consecutive regular expirations was measured and a mean value calculated for each patient. The best of three PEFRs was determined. The PEFR and dco2/dt were also recorded after treatment of the asthmatic patients with inhaled beta-agonists. RESULTS: The mean +/- SD PEFR of the asthmatic subjects was 274 +/- 96 L/minute (57% of the predicted value), whereas that of the normal volunteers was 527 +/- 96 L/minute (103% of the predicted value) (P < .001). The mean dco2/dt of the asthmatic subjects (.26 +/- .06) was significantly steeper than that of the normal volunteers (.13 +/- .06) (P < .001). The dco2/dt was correlated with PEFR (r = .84, P < .001). In 18 asthmatic subjects the pretreatment and posttreatment percent predicted PEFRS were 58% +/- 17% and 74% +/- 17%, respectively (P < .001), whereas the dco2/dt values were .27 +/- .05 and .19 +/- .07, respectively (P < .005). CONCLUSION: The dco2/dt is an effort-independent, rapid noninvasive measure that indicates significant bronchospasm in ED adult patients with asthma. The dco2/dt value is correlated with PEFR, an effort-dependent measure of airway obstruction. The change in dco2/dt with inhaled beta-agonists may be useful in monitoring the therapy of acute asthma.

Adrenergic beta-Agonists↗

Preliminary study of the capnogram waveform area to screen for pulmonary embolism.

STUDY OBJECTIVE: Acute pulmonary embolism (PE) increases alveolar dead space, which can dilute carbon dioxide content in exhaled breath. This study was undertaken to determine whether the capnogram waveform area from patients with PE is decreased compared with that from patients without PE and to examine the potential role of the capnogram waveform area as a screening test for PE. METHODS: Studies were conducted on patients from a large, urban emergency department. Steady-state capnograms were collected from subjects breathing room air, and data were electronically stored for later analysis; arterial blood was collected for blood gas analysis. PE was diagnosed or excluded on the basis of appropriate combinations of isotopic ventilation-perfusion lung scanning, lower-extremity venous Doppler ultrasound studies, and pulmonary angiography. Capnogram areas were measured by tracing waveforms on printed copies with an electronic digitizing tablet. RESULTS: The mean capnogram area from patients with PE (n=19) was 28+/-10 mm Hg x sec, significantly less than for patients without PE (n=120), 53+/-17 mm Hg x sec (95% confidence interval [CI] for a difference of 25 mm Hg x sec, 17 to 33 mm Hg x sec). At a cutoff of 50 mm Hg x sec, the test sensitivity was 100% (95% CI, 82% to 100%), with a negative likelihood ratio (LR-) of .17, and the specificity was 53% (95% CI, 44% to 62%), with a positive likelihood ratio (LR+) of 2.1. At a cutoff of 25 mm Hg x sec, the test sensitivity was 42% (95% CI, 20% to 67%; LR-, .6) and the specificity was 97% (95% CI, 92% to 99%; LR+, 12.3). The area under the smoothed receiver operating characteristic curve for the capnogram area was .896 (95% Cl, .80 to .99). CONCLUSION: The capnogram waveform area may be useful in screening for PE in the ED.

Adolescent↗

Monitoring during mechanical ventilation.

Approximately half of the patients admitted to an ICU are admitted for the purposes of monitoring rather than interventional therapy. In the last decade, significant technologic advances have enhanced monitoring capacities, and the understanding of the pathophysiology of respiratory failure has improved pari passu, allowing clinicians to employ monitors in a more intelligent manner. This article deals with new developments in arterial blood gas monitoring, pulse oximetry, capnometry, and monitoring of neuromuscular function and pulmonary mechanics, emphasizing issues most relevant to mechanical ventilation.

Blood Gas Analysis↗

A portable quantitative capnometer in test.

A new hand-held quantitative capnometer (BCI Capnocheck) was tested in the animal lab setting. The end-tidal CO2 values, as measured with this device, showed good agreement with arterial (Paco2) values. This device seems suited for quantitative capnometry in the prehospital setting. It must be noted, however, that this device has no alarms.

Animals↗

Preliminary observations on the Colibri CO2-indicator.

The performance of a new colorimetric CO2-indicator (Colibri) was assessed in mini-pigs. It performed well during 8-hour procedures. Neither nitrous oxide, nor halothane, nor carbon monoxide, nor intratracheal application of drugs (epinephrine, atropine, lidocaine, and naloxone) interfered with its function. It gave a distinct color change at high ventilation frequencies up to 120/min. The only problem observed was difficulty in matching the colors displayed with the comparison color chart provided. The Colibri's performance seems at least equal to that of the EasyCAP detector, although both devices share some disadvantages (no alarms, semiquantitative, difficult reading in the dark). After initial control of endotracheal tube position by an esophageal detector device, both the Colibri and the EasyCAP seem suited for monitoring of ventilation and circulation if quantitative capnometry is unavailable.

Animals↗

Utility of colorimetric end-tidal carbon dioxide detector for monitoring during prehospital cardiopulmonary resuscitation.

The purpose of this study was to evaluate a colorimetric end-tidal CO2 (ETCO2) detector (EASY CAP) as a monitor during prehospital cardiopulmonary resuscitation (CPR) without tracheal intubation. This detector was used for 121 patients during CPR with a laryngeal mask airway or face mask by authorized emergency lifesaving technicians. At 7 to 15 minutes after the initiation of CPR, ETCO was <0.5% in 30 cases (group A), 0.5% to 2.0% in 46 cases (group B) and >2.0% in 45 cases (group C). The rate of return of spontaneous circulation was 17% in group A, 24% in group B, and 48% in group C (groups A v C, P < .01). There was a significant difference in the rate of hospital admission between groups A and C. The ETCO2 value may be useful for monitoring during prehospital CPR with a laryngeal mask airway or face mask.

Adult↗

Ventilatory management in the postanesthesia care unit.

Postoperative ventilatory depression is common in patients who have received intravenous and inhalational anesthetic agents. Prompt assessment and treatment of ventilatory depression are essential to minimize morbidity and mortality.

Capnography↗

Comparative incidence of venous air embolism and associated hypotension in adults and children operated for neurosurgery in the sitting position.

BACKGROUND AND OBJECTIVE: Venous air embolism is a constant threat during neurosurgery performed in the sitting position. No large prospective study has compared the incidence of venous air embolism and associated hypotension between adults and children. METHODS: Four hundred and thirty patients (334 adults, 96 children) scheduled to undergo planned posterior fossa surgery in the sitting position (between January 1989 to December 1994) were studied with end-tidal carbon dioxide monitoring. Intraoperatively, a sudden and sustained decrease in end-tidal carbon dioxide tension of >0.7 kPa was presumed to be due to venous air embolism. Management during the episode was on the established guidelines. Hypotension (decrease in systolic arterial pressure of 20% or more from the previous level) was treated with crystalloids and/or a vasopressor. RESULTS: Capnometry detected a 28% incidence rate of air embolism in adults (93/334) and a 22% incidence rate in children (21/96) (P = 0.29). In both groups, the highest incidence rate of embolism took place during muscle handling (44% of adults versus 38% of children, P = 0.8). Embolic episodes were accompanied by hypotension in 37% of adults (34/93) and in 33% of children (7/21) (P = 0.98). To restore arterial pressure to pre-embolic levels, 53% of adults (18/34) and 43% of children (3/7) were administered vasopressors (P = 0.94). There was no intraoperative mortality. The surgical procedure on one adult was abandoned because of persistent hypotension following the embolic episode. CONCLUSION: The incidence of venous air embolism and consequent hypotension is similar in adults and children.

Adult↗

Checking the capnograph before anaesthesia: a survey of national practice in the UK.

BACKGROUND AND OBJECTIVE: Recently published guidelines for checking anaesthetic equipment do not contain specific advice on how to check the correct functioning of the capnograph before inducing anaesthesia. METHODS: We undertook a postal survey of UK consultant (physician) anaesthetists to establish what methods for checking the capnograph are currently in use. Two hundred and two questionnaires were sent to consultants in different hospitals and 163 returned, a response rate of 81%. RESULTS: 52.1% consultants of check the capnograph themselves. Of these, 55.3% use their own expired breath to confirm a response to carbon dioxide. Other methods used by consultant anaesthetists to check capnograph function include the machine self-test (16.5%), visual checks of the capnograph and sampling tubing (10.3%), and sampling of patient expired carbon dioxide (7.1%). CONCLUSION: The most common method for testing capnograph function among consultant anaesthetists and their assistants in the UK is the direct measurement of exhaled breath.

Anesthesia↗

Assessment of errors when expiratory condensate PCO2 is used as a proxy for mixed expired PCO2 during mechanical ventilation.

OBJECTIVES: We designed a series of experiments to determine whether expiratory water condensate (PconCO2) can be used as a proxy for mixed expired gas collection. METHODS: In 18 adult mechanically ventilated patients with ARDS (40 samples), simultaneous collections of arterial blood, expiratory water trap condensate, mixed expired gas, and minute ventilation were used to calculate VCO2 and VD/VT. To assess the effect of temperature, a constant gas flow (PCO2 10-30 mm Hg) was bubbled through water at temperatures of 19.5-37 degrees C. Gas and water samples were collected, immediately analyzed for PCO2, and a temperature correction factor was calculated. A lung model was constructed using a 5 L anesthesia bag connected to a mechanical ventilator with a heated humidifier. Temperature at the Y-piece was set to approximately 37 degrees C and CO2 was injected into the bag to establish an end-tidal PCO2 of 20-70 mm Hg. After equilibration, condensate was collected, PCO2 was measured, and the temperature-corrected PCO2 was compared to PECO2. The capnogram at points along the expiratory limb circuit was used to evaluate gas mixing. RESULTS: There was an over-estimation of PECO2 by PconCO2 (p < 0.001) for the patient data, resulting in an underestimation of VD/VT (p < 0.001) and an overestimation of VCO2 (p < 0.001). The temperature correction factor for PCO2 in water was -0.010 (about half of the factor used for whole blood). The bias between temperature-corrected PconCO2 and PECO2 was 0.3 +/- 3.2 mm Hg in the lung model. Mixing in the expiratory limb was poor, as evaluated by the capnogram. CONCLUSIONS: Even with temperature correction, we failed to precisely predict PECO2 from PconCO2. For measurement of VD/VT and VCO2, we do not recommend methods that use PconCO2.

Adult↗