Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Simple method for determination of hydrochlorothiazide in human urine by high performance liquid chromatography utilizing narrowbore chromatography.

A simple high performance liquid chromatographic (HPLC) method utilizing narrowbore chromatography was developed for the determination of hydrochlorothiazide in human urine. A mobile phase of 0.1% aqueous acetic acid--acetonitrile (93:7, v/v) pH 3 was used with a C18 analytical column and ultraviolet detection (UV). The method demonstrated linearity from 2 to 50 micrograms ml-1 using 50 microliters of urine with a detection limit of 1 microgram ml-1. The method was utilized in a study evaluating if racial differences are present in the pharmacokinetic and pharmacodynamic effects of hydrochlorothiazide.

Black People↗

Comparison of different liquid chromatography conditions for the separation and analysis of organotin compounds in mussel and oyster tissue by liquid chromatography-inductively coupled plasma mass spectrometry.

In this paper, a new high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) methodology for the analysis of organotin compounds in complex matrices is described. Earlier studies had failed to show baseline resolution between dibutyltin (DBT) and triphenyltin (TPhT). The data presented in this paper show that, by using a different C-18 stationary phase material (Ace C-18) with decreased particle size, baseline resolution of DBT and TPhT can be achieved, with the resultant separation of a third interfering component. In addition, the Ace C-18 stationary phase yields a significant increase in the number of theoretical plates, and, combined with changes in the mobile phase composition, a reduction in run-time by approximately 25%. It is shown that the minor compounds detected are present in the sample and not artefacts of the analytical procedure. The accuracy and precision of the proposed HPLC-ICP-MS method was demonstrated for the determination of TBT in oyster tissue during the BCR "MULSPOT" international interlaboratory certification project.

Animals↗

Comparison of packed-column supercritical fluid chromatography--tandem mass spectrometry with liquid chromatography--tandem mass spectrometry for bioanalytical determination of (R)- and (S)-ketoprofen in human plasma following automated 96-well solid-phase extraction.

The popularity of packed-column supercritical fluid, subcritical fluid, and enhanced fluidity liquid chromatographies (pcSFC) for enantiomeric separations has increased steadily over the past few years. The addition of a significant amount (typically 20-95%) of a viscosity lowering agent, such as carbon dioxide, to the mobile phase provides a number of advantages for chiral separations. For example, higher mobile-phase flow rates can often be attained without a concomitant loss in chromatographic efficiency since diffusion coefficients, and optimum velocities, are typically higher in pcSFC. Ultratrace enantioselective quantitation of drugs in biomatrixes is an ideal application for these chromatographic attributes. To demonstrate the utility of this approach, a pcSFC tandem mass spectrometry (pcSFC-MS/MS) method was compared to a LC-MS/MS method for quantitation of the (R)- and (S)-enantiomers of ketoprofen (kt), a potent nonsteroidal, anti-inflammatory drug, in human plasma. After preparation using automated solid-phase extraction in the 96-well format, kt enantiomers were separated on a Chirex 3005 analytical column using isocratic conditions. Validation data and study sample data from patients dosed with either orally or topically administered ketoprofen were generated using both pcSFC and LC as the chromatographic methods to compare and contrast these analytical approaches. Generally, most analytical attributes, including specificity, linearity, sensitivity, accuracy, precision, and ruggedness, for both of these methods were comparable with the exception that the pcSFC separation provided a roughly 3-fold reduction in analysis time. A 2.3-min pcSFC separation and a 6.5-min LC separation provided equivalent, near-baseline-resolved peaks, demonstrating a significant time savings for analysis of large batch pharmacokinetic samples using pcSFC.

Anti-Inflammatory Agents, Non-Steroidal↗

High-performance liquid chromatography of amino acids, peptides, and proteins. 123. Dynamics of peptides in reversed-phase high-performance liquid chromatography.

The dynamics of several peptides in reversed-phase high-performance liquid chromatography (RP-HPLC) have been investigated on both n-octadecyl (C18) silica and n-butyl (C4) silica sorbents. In particular, the conformational interconversions and the relative rates of chromatographic relaxation of bombesin, glucagon, and beta-endorphin on both C18 and C4 n-alkylsilicas were monitored by examining changes in the experimental bandwidths of these peptides as a function of temperature and column residence time under linear gradient elution RP-HPLC conditions. The observed band-broadening trends were correlated with previously derived retention parameters and thermodynamic descriptors of the association process determined for bombesin, beta-endorphin, glucagon, and a control peptide, penta-L-phenylalanine. This study confirms that bandwidth measurements can be used as an integral experimental component to study the effect of the secondary structure of peptidic solutes on their RP-HPLC retention behavior. Further, the data demonstrate the utility of RP-HPLC as a tool to examine peptide conformational dynamics at hydrophobic surfaces. The relevance of these results to the general phenomenon of peptide-lipid interactions is discussed in terms of the associated evidence for lipid-induced changes in the conformation of these three bioactive peptides.

Amino Acid Sequence↗

High-performance liquid chromatography of complex mixtures using monodisperse dual-chemistry polymer beads prepared by a pore-size-specific functionalization process. A single column combination of hydrophobic interaction and reversed-phase chromatography.

A novel separation medium for HPLC combining hydrophobic interaction and reversed-phase separation modes in a single column has been prepared from monodisperse 10-microns poly-(glycidyl methacrylate-co-ethylene dimethacrylate) beads using a pore-size-specific functionalization process. In this approach, the large pores of each bead were provided with phenyl groups interspersed among hydrophilic functionalities while a much higher surface concentration of hydrophobic phenyl groups was introduced into the small pores. Due to the size-specific character of the modification process, no protein interaction with any highly hydrophobic surface was observed during chromatography. The beads were used for the separation of samples containing both proteins and small hydrocarbon or drug molecules. A plot of log k' against salt concentration in the mobile phase clearly documents the clean hydrophobic interaction mechanism of protein separation and the absence of charged groups while the linear plot of log k' against acetonitrile concentration for numerous compounds demonstrates the reversed-phase separation ability. No decrease of the efficiency of the test column (23,000 plates/m) was observed in long-term experiments during which more than 1000 injections and many changes between the modes were performed.

Chemical Phenomena↗

Combination of high-performance liquid chromatography and microplate scintillation counting for crop and animal metabolism studies: a comparison with classical on-line and thin-layer chromatography radioactivity detection.

Samples from crop or animal metabolism studies of pesticides were used to evaluate the performance of the combination of analytical or narrow-bore HPLC and microplate scintillation counting (TopCount). Samples with extreme matrix content such as grain and tomato extracts from crop metabolism studies as well as extracts from hen excreta or goat urine from farm animal metabolism studies could be injected, analyzed, and quantified directly without any sample pretreatment. The minimum amount of radioactivity injected was approximately 1 Bq (60 dpm). Counting times from 5 to 60 min were used for detection and quantification. These results were compared with those from classical on-line radioactivity detection and with radioactivity detection on thin-layer chromatography plates.The combination of analytical or narrow-bore HPLC and microplate scintillation counting (TopCount) offers high sensitivity and high resolution power at the same time. It could be clearly demonstrated that the combination of HPLC with microplate scintillation counting is superior to the classical on-line radioactivity detection and at least equivalent to the classical thin-layer radiochromatography regarding performance and sensitivity.

Animals↗

Expression of multivalency in the affinity chromatography of antibodies. Appendix: Derivation and evaluation of equations for independent bivalent interacting systems in quantitative affinity chromatography.

The expression of multivalency in the interaction of antibody with immobilized antigen was evaluated by quantitative affinity chromatography. Zones of radioisotopically labeled bivalent immunoglobulin A monomer derived from the myeloma protein TEPC 15 were eluted from columns of phosphorylcholine-Sepharose both in the absence and presence of competing soluble phosphorylcholine. At sufficient immobilized phosphorylcholine concentration, the variation of elution volume of bivalent monomer with soluble ligand was found to deviate from that observed for the univalent binding of the corresponding Fab fragment. In addition, the apparent binding affinity of the bivalent monomer increased with immobilized antigen density. Use of equations relating the variation of elution volume with free ligand concentration for a bivalent binding protein allowed calculation of microscopic single-site binding parameters for the bivalent monomeric antibody to both immobilized and soluble phosphorylcholine. The chromatographic data not only demonstrate the effect of multivalency on apparent binding affinity but also offer a relatively simple means to measure microscopic dissociation constants for proteins participating in bivalent interactions with their ligands.

Antibodies↗

Analysis of eight capsaicinoids in peppers and pepper-containing foods by high-performance liquid chromatography and liquid chromatography-mass spectrometry.

Diverse procedures have been reported for the isolation and analysis of secondary metabolites called capsaicinoids, pungent compounds in the fruit of the Capsicum (Solanaceae) plant. To further improve the usefulness of high-performance liquid chromatography (HPLC), studies were carried out on the analysis of extracts containing up to eight of the following capsaicinoids: capsaicin, dihydrocapsaicin, homocapsaicin-I, homocapsaicin-II, homodihydrocapsaicin-I, homodihydrocapsaicin-II, nonivamide, and nordihydrocapsaicin. HPLC was optimized by defining effects on retention times of (a) the composition of the mobile phase (acetonitrile/0.5% formic acid in H2O), (b) the length of the Inertsil column, and (c) the capacity values (k) of the column packing. Identification was based on retention times and mass spectra of individual peaks. Quantification was based on the UV response at 280 nm in HPLC and recoveries from spiked samples. The method (limit of detection of approximately 15-30 ng) was successfully used to quantify capsaicinoid levels of parts of the pepper fruit (pericarp, placenta, seeds, and in the top, middle, and base parts of whole peppers) in 17 species of peppers and in 23 pepper-containing foods. The results demonstrate the usefulness of the method for the analysis of capsaicinoids ranging from approximately 0.5 to 3600 microg of capsaicin equiv/g of product. The water content of 12 fresh peppers ranged from 80.8 to 92.7%. The described freeze-drying, extraction, and analysis methods should be useful for assessing the distribution of capsaicinoids in the foods and in defining the roles of these biologically active compounds in the plant, the diet, and medicine.

California↗

Development of a liquid chromatography-tandem mass spectrometry method using capillary liquid chromatography and nanoelectrospray ionization-quadrupole time-of-flight hybrid mass spectrometer for the detection of milk allergens.

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of the tryptic digest of a cleaned-up food matrix extract was used for the detection of milk allergens. The emphasis of this study was on casein, which is the most abundant milk protein and is also considered the most allergenic. A sample cleanup method was developed using an ion exchange column and centriprep device. Cookies spiked with milk powder from 0 to 1250 ppm were extracted, cleaned up, and either digested directly by trypsin or further cleaned up by gel electrophoresis before digestion. The peptide mixture was analyzed on a capillary LC-quadrupole time-of-flight system. Two marker peptides from alphaS1-casein were identified and used for prescreening. The MS/MS data from the mass spectrometry system were processed with Masslynx v4.0 and submitted for database search using either ProteinLynx Global Server or Mascot for protein identification. The LC-MS/MS method, using casein enzyme-linked immunosorbent assay as a reference, was tested on the cookie matrix and was extended to other sample matrices. There were good agreements between the two. This LC-MS/MS method provides a valuable confirmatory method for the presence of casein. It also allows the simultaneous detection of other milk allergens.

Allergens↗

Determination of sulfonylurea herbicides in water and food samples using sol-gel glass-based immunoaffinity extraction and liquid chromatography-ultraviolet/diode array detection or liquid chromatography-tandem mass spectrometry.

Immunoaffinity supports (IAS) were prepared using broad specific polyclonal anti-sulfonylurea (SU) antibodies immobilized in sol-gel glass. Two different kinds of supports were applied, crushed sol-gel monoliths and sol-gel-coated highly porous silica particles. Both were used for the quantitative enrichment of SUs in natural water and food samples followed by high-performance liquid chromatography-ultraviolet/diode array detection (HPLC-UV/DAD) and tandem mass spectrometry (LC-MS/MS), respectively. Loading, washing, and elution conditions of IAS were optimized. The capacity of supports was determined for 30 SUs and compared with the cross-reactivity pattern of the direct competitive enzyme-linked immunosorbent assay. The capacities correlated well with the affinity to individual SU compounds. Even analytes to which the polyclonal antibodies showed only a lower cross-reactivity could be enriched to a certain degree, if a sufficient capacity of IAS was provided. The IAS could be reused at least 10 times without a loss of effectiveness. Recovery of 16 selected SUs extracted from spiked water and food samples was dependent on the affinity of both immobilized antibodies to single compounds and matrix interferences. In water, 13 SUs showed recoveries higher than 80% when immunoaffinity extraction was used in combination with LC-UV/DAD. On the basis of the enrichment of 200 mL of aqueous sample, corresponding limit of detection (LOD) values ranged between 20 and 100 ng/L. The recoveries of 10 SUs, which were extracted from 10 g of potato spiked at a 10 microg/kg level, were higher than 75%. For grain samples, recoveries were at the same order for at least five SU herbicides. The LOD of LC-MS/MS measurements was about 1 order of magnitude higher, i.e., gave LODs between 1.1 and 6.9 microg/kg of food sample, depending on the compound and extraction procedure. These LODs provide evidence that the main advantage of the prepared IAS is their high selectivity for group specific recognition of SUs as compared to other nonspecific solid phase extraction materials.

Chromatography, High Pressure Liquid↗

Determination of malachite green residues in rainbow trout muscle with liquid chromatography and liquid chromatography coupled with tandem mass spectrometry.

A method for the determination of malachite green and its major metabolite leucomalachite green in rainbow trout muscle is reported with limits of detection of 0.8 and 0.6 microg kg(-1), respectively. Residues were extracted with an acetonitrile-acetate buffer mixture and partitioned into methylene chloride. Clean-up of the extracts was performed on alumina and propylsulfonic acid solid-phase extraction columns using the automated solid-phase extraction system. The chromatographic separation of malachite green and leucomalachite green was achieved on a Chromspher 5B column using an acetonitrile-acetate buffer mobile phase. Leucomalachite green was converted to malachite green by post-column oxidation before spectrophotometric detection at 600 nm. The mean recoveries of malachite green and leucomalachite green from control rainbow trout muscle spiked at 2-50 microg kg(-1) were 65% (range 63.4-65.9%, relative standard deviation 3.9-16.1%) and 74% (range 58.3-82.6%, relative standard deviation 3.3-11.4%), respectively. Qualitative confirmation of the determined residues was performed with liquid chromatography coupled with tandem mass spectrometry detection with limits of detection of 2.5 and 1 microg kg(-1) for malachite green and leucomalachite green, respectively.

Aniline Compounds↗

[Analysis of atmospheric pollutants with coupled gas chromatography-atomic absorption or thermodesorption-gas chromatography].

We have perfected a specific and original analytical method suitable for organic and inorganic compounds using sampled run-off water collected nearby a filling station. The dissolved lead species are volatilized by substituting the inorganic ligands with hydrogen, using sodium-borohydride in a suitable reaction medium (H2O2, KOH). The volatile lead hydrides are then trapped on a gas chromatographic column filled with Chromosorb W impregnated with 2% of OV 275 and immersed in liquid nitrogen. After desorption, the products are analysed by atomic absorption spectroscopy. We have carried out the analysis of aldehydes mixtures, sampled from a smog chamber. They are trapped, at room temperature, in a glass column filled with Tenax. These pollutants are then heated at 250 degrees C under a flow of nitrogen, and trapped again in a melted silica capillary column at -110 degrees C. This trapping being over, the column is drastically heated at 200 degrees C, which drives the products into the capillary column of a gas-chromatograph apparatus. This method has also enabled us to carry out a direct analysis of these pollutants sorbed on particles which have been placed into the glass column. this thermodesorption-gas chromatography system, coupled with a mass-spectrometry apparatus, allows us to identify and analyse most atmospheric pollutants.

Air Pollutants↗

Gas and liquid chromatography of hydroxybiphenyls, chlorinated hydroxybiphenyls and several types of halogenated derivatives. I. Capillary gas chromatography and mass spectrometry.

For 8 hydroxybiphenyls and 19 chlorinated hydroxybiphenyls derivatization reactions with 6 electrophilic reagents--viz., 4 perfluoro anhydrides, pentafluorobenzoyl chloride and tert.-butylpentafluorophenylmethylchlorosilane--have been studied to evaluate their potential for capillary gas chromatography with electron-capture detection. For some of the classes of derivatives, mass spectrometric data are presented.

Biphenyl Compounds↗

The extraction and analysis of 1,4-dioxane from water using solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry.

In this study, two methods are developed for the extraction of 1,4-dioxane (dioxane) from water using 80-microm carboxen-polydimethylsiloxane solid-phase microextraction fibers followed by either gas chromatography (GC)-flame ionization detection (FID) or GC-mass spectrometry (MS). With GC-FID, the lower limit of detection (LOD) for 1,4-dioxane is 2.5 microg/L (ppb) with a linear range of 5 to 10,000 microg/L, obtained by immersing the fiber in the sample for 20 min with agitation. Using GC-MS, the lower limit of quantitation is 0.5 microg/L, and the LOD is 0.25 microg/L. The upper linear range limit is 100 microg/L. Samples are extracted in 20 min using either heated headspace with agitation or direct immersion with agitation.

Dioxanes↗

Optimisation of conditions for the affinity chromatography of human enterokinase on immobilised p-aminobenzamidine. Improvement of the preparative procedure by inclusion of negative affinity chromatography with glycylglycyl-aniline.

The affinity chromatography of human enterokinase using p-aminobenzamidine as the ligand [Grant, D.A.W. & Hermon-Taylor, J. (1976) Biochem. J. 155, 243-254] has been reassessed and the optimal conditions for the synthesis and operation of the derivatised gel defined. Satisfactory adsorbants were only produced using high concentrations of both CNBr and spacer-arm in the initial coupling slurry. Under these conditions it seemed likely that the majority of the ligand in a sterically favourable position to bind enterokinase was on the external surface of the bead. Trypsin binding to the adsorbant was not so critically dependent on the synthetic conditions and correlated closely with the degree of substitution. Dilution of the adsorbant with unlabelled Sepharose 4B indicated that there was more than one binding site per enterokinase molecule. The highest affinity was presumably for the active site, with adsorption supported by secondary interactions with spacer-arm or gel matrix not necessarily on the same bead. Maximal resolution was obtained by prolonged washing of the gel after loading; two populations of intestinal aminopeptidase were identified. Substitution of aniline for p-aminobenzamidine abolished specific enterokinase adsorption and improved the purification procedure by further removal of onon-specifically adsorbed contaminants.

Amidines↗

Determination of sperm-antibodies in sera of sterile women by affinity-chromatography (affinity-chromatography of sperm-antibodies).

The total amount of humoral sperm antibody protein is determined following its isolation by affinity-chromatography on spermatozoa. Serum proteins are eluted by Sorensen phosphate buffer. Antibodies attached to spermatozoa suspended in Sephadex G 75 columns resist elution by Sorensen buffer. They can be quantitatively washed out by 8 ml Tris HCl-buffer pH 8,9 and be determined as proteins by the Folin-Ciocalteu method.

Adsorption↗

Advances in analytical techniques for neutron capture therapy: thin layer chromatography matrix and track etch thin layer chromatography methods for boron-10 analysis.

A new track etch autoradiographic technique for quantitating boron-10 containing compounds used for neutron capture therapy is described. Instead of applying solutions of Cs2B12H11SH and its oxidation products directly to solid-state nuclear track detectors, diethylaminoethyl cellulose thin layer chromatography (TLC) plates are utilized as sample matrices. The plates are juxtaposed with Lexan polycarbonate detectors and irradiated in a beam of thermal neutrons. The detectors are then chemically etched, and the resultant tracks counted with an optoelectronic image analyzer. Sensitivity to boron-10 in solution reaches the 1 pg/microliter level, or 1 ppb. In heparinized blood samples, 100 pg boron-10/microliter are detected. This TLC matrix method has the advantage that sample plates can be reanalyzed under different reactor conditions to optimize detector response to the boron-10 carrier material. Track etch/TLC allows quantitation of the purity of boron neutron capture therapy compounds by utilizing the above method with TLC plates developed in solvent systems that resolve Cs2B12H11SH and its oxidative analogs. Detectors irradiated in juxtaposition to the thin layer chromatograms are chemically etched, and the tracks are counted in the sample lane from the origin of the plate to the solvent front. A graphic depiction of the number of tracks per field yields a quantitative analysis of compound purity.

Boron↗