Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Localized membrane depolarizations and localized calcium influx during electric field-guided neurite growth.

Our study explores the mechanisms behind neurite galvanotropism. Using phase, differential interference contrast and ratiometric fluorescence microscopy, we reveal four responses of N1E-115 mouse neuroblastoma cells to 0.1-1.0 mV/microns uniform DC electric fields: cathode-directed neurite initiation and elongation, cathode-biased growth cone filopodial protrusions, transient cathode-localized calcium increases, and persistent cathode-localized membrane depolarizations. These newly demonstrated events are temporally and spatially correlated, suggesting that they are causally related. The calcium increases are prevented by calcium channel blockers and by the removal of extracellular calcium. We therefore propose that the observed field-induced membrane depolarizations activate voltage-dependent calcium channels, resulting in cathode-localized calcium influx. This, in turn, may initiate the observed cathode-biased growth cone filopodial protrusions, followed by the cathode-directed neurite elongation.

Animals↗

Removal of heavy metals from kaolin using an upward electrokinetic soil remedial (UESR) technology.

An upward electrokinetic soil remedial (UESR) technology was proposed to remove heavy metals from contaminated kaolin. Unlike conventional electrokinetic treatment that uses boreholes or trenches for horizontal migration of heavy metals, the UESR technology, applying vertical non-uniform electric fields, caused upward transportation of heavy metals to the top surface of the treated soil. The effects of current density, treatment duration, cell diameter, and different cathode chamber influent (distilled water or 0.01 M nitric acid) were studied. The removal efficiencies of heavy metals positively correlated to current density and treatment duration. Higher heavy metals removal efficiency was observed for the reactor cell with smaller diameter. A substantial amount of heavy metals was accumulated in the nearest to cathode 2 cm layer of kaolin when distilled water was continuously supplied to the cathode chamber. Heavy metals accumulated in this layer of kaolin can be easily excavated and disposed off. The main part of the removed heavy metals was dissolved in cathode chamber influent and moved away with cathode chamber effluent when 0.01 M nitric acid was used, instead of distilled water. Energy saving treatment by UESR technology with highest metal removal efficiencies was provided by two regimes: (1) by application of 0.01 M nitric acid as cathode chamber influent, cell diameter of 100 mm, duration of 18 days, and constant voltage of 3.5 V (19.7 k Wh/m(3) of kaolin) and (2) by application of 0.01 M nitric acid as cathode chamber influent, cell diameter of 100 cm, duration of 6 days, and constant current density of 0.191 mA/cm(2) (19.1 k Wh/m(3) of kaolin).

Algorithms↗

High-voltage pulsed current: its influence on diameters of histamine-dilated arterioles in hamster cheek pouches.

Results from five independent studies from our laboratory indicate that cathodal high-voltage pulsed current (HVPC) significantly curbs posttraumatic edema formation in several animal models. Conversely, anodal HVPC did not curb edema formation. The mechanism by which HVPC reduces edema formation is unknown. We hypothesize that HVPC causes a decrease in local blood flow by active vasoconstriction of arterioles. Because we had previously observed positive effects with cathodal HVPC but not anodal HVPC, we further hypothesized that cathodal but not anodal HVPC would reduce diameters of histamine-dilated arterioles. Changes in diameters of resistance arterioles (5 to 30 microns internal diameter) were measured directly in cheek pouches of anesthetized hamsters, using in vivo video microscopy. Three minutes after superfusion with the inflammatory mediator (histamine) was begun, sensory-level HVPC at 120pps was applied concurrently for 30 minutes. Five animals received cathodal HVPC and five received anodal HVPC. Four other animals received 30-minute treatments of both cathodal and anodal HVPC in random order. Three control animals received histamine without HVPC for 30 minutes. Diameter changes of one arteriole from each cheek pouch was measured every 20 seconds throughout the treatment period. One-way analysis of variance (ANOVA) with repeated measures showed that diameters of histamine-dilated controls varied little over 30 minutes, and that adding cathodal HVPC did not significantly alter diameters of arterioles superfused with histamine. However, applying anodal HVPC to histamine-dilated arterioles significantly reduced arteriolar diameters. These results do not support the hypothesis that cathodal HVPC curbs edema formation by increasing arteriolar tone in the injured area.

Animals↗

Reductive dehalogenation of gas-phase chlorinated solvents using a modified fuel cell.

The reductive dehalogenation of gas-phase chlorinated alkanes (CCl4, CHCl3, and 1,1,1-trichloroethane) and alkenes (perchloroethene (PCE) and trichloroethene (TCE)) was conducted in a modified fuel cell. The fuel-cell performance was a function of cathode material, electric potential, temperature, target compound identity and gas-phase concentration, partial pressure of O2 in the cathode chamber, and cathode condition (time in service). TCE conversion was approximately first order in TCE concentration with half-lives of fractions of a second. Under the same reactor conditions, CCl4 transformation was faster than CHCl3, and TCE reduction was faster than PCE. Rates of both CCl4 and PCE transformation increased substantially with temperature in the range of 30-70 degrees C. At 70 degrees C and a potential (potential of the cathode minus that of the anode) of -0.4 V, single-pass CCl4 conversions were approximately 90%. Mean residence time for gases in the porous cathode was much less than 1 s. The presence of even 5% O2(g) in the influent to the cathode chamber had a deleterious effect on reactor performance. Performance also deteriorated with time in service, perhaps due to the accumulation of HCl on the cathode surface. Conversion efficiency was restored, however, by temporarily eliminating the halogenated target(s) from the influent stream or by briefly reversing fuel-cell polarity.

Air Pollutants↗

Air-breathing laminar flow-based microfluidic fuel cell.

This communication reports the design and characterization of an air-breathing laminar flow-based microfluidic fuel cell (LFFC). The performance of previous LFFC designs was cathode-limited due to the poor solubility and slow transport of oxygen in aqueous media. Introduction of an air-breathing gas diffusion electrode as the cathode addresses these mass transfer issues. With this design change, the cathode is exposed to a higher oxygen concentration, and more importantly, the rate of oxygen replenishment in the depletion boundary layer on the cathode is greatly enhanced as a result of the 4 orders of magnitude higher diffusion coefficient of oxygen in air as opposed to that in aqueous media. The power densities of the present air-breathing LFFCs are 5 times higher (26 mW/cm2) than those for LFFCs operated using formic acid solutions as the fuel stream and an oxygen-saturated aqueous stream at the cathode ( approximately 5 mW/cm2). With the performance-limiting issues at the cathode mitigated, these air-breathing LFFCs can now be further developed to fully exploit their advantages of direct control over fuel crossover and the ability to individually tailor the chemical composition of the cathode and anode media to enhance electrode performance and fuel utilization, thus increasing the potential of laminar flow-based fuel cells.

Journal Article↗

Electrochemical reduction of carbon dioxide on pyrite as a pathway for abiogenic formation of organic molecules.

A wide spectrum of electrode potentials of minerals that compose sulfide ores enables the latter, when in contact with hydrothermal solutions, to form galvanic pairs with cathode potentials sufficient for electrochemical reduction of CO2. The experiments performed demonstrated the increase of cathode current on the rotating pyrite disc electrode in a range of potentials more negative than -800 mV in presence of CO2. In high-pressure experiments performed in a specially designed electrochemical cell equipped with a pyrite cathode and placed into autoclave, accumulation of formate was demonstrated after 24 hr passing of CO2 (50 atm, room temperature) through electrolyte solution. The formation of this product started on increasing the cathode potential to -800 mV (with respect to saturated silver chloride electrode). The yield grew exponentially upon cathode potential increase up to -1200 mV. The maximum current efficiency (0.12%) was registered at cathode potentials of about -1000 mV. No formate production was registered under normal atmospheric pressure and in the absence of imposed cathode potential. Neither in experiments, nor in control was formaldehyde found. It is proposed that the electrochemical reduction of CO2 takes part in the formation of organic molecules in hydrothermal solutions accompanying sulfide ore deposits and in 'black smokers' on the ocean floor.

Carbon Dioxide↗

Electrical stimulation of cardiac tissue: a bidomain model with active membrane properties.

Numerical calculations simulated the response of cardiac muscle to stimulation by electrical current. The bidomain model with unequal anisotropy ratios represented the tissue, and parallel leak and active sodium channels represented the membrane conductance. The speed of the wavefront was faster in the direction parallel to the myocardial fibers than in the direction perpendicular to them. However, for cathodal stimulation well above threshold, the wavefront originated farther from the cathode in the direction perpendicular to the myocardial fibers than in the direction parallel to them, consistent with observations of a dog-bone-shaped virtual cathode made by Wikswo et al., Circ. Res. 68:513-530, 1991. The model showed that the virtual cathode size and shape were dependent upon both membrane and tissue conductivities. Increasing the peak sodium conductance or reducing the transverse intracellular conductivity accentuated the dog-bone shape, while the opposite change caused the virtual cathode to become more elliptical, with the major axis of the ellipse transverse to the fiber direction. A cathodal stimulus created regions of hyperpolarization that slowed conduction of the wavefront propagating parallel to the fibers. An anodal stimulus evoked a wavefront with a complex shape; activation originated from two depolarized regions 1 to 2 mm from the stimulus site along the fiber direction. The threshold current strength (0.5 ms duration pulse) for a cathodal stimulus was 0.048 mA, and for an anodal stimulus was 0.67 mA. When the model was modified to simulate the effect of electropermeabilization, which may be present when the transmembrane potential reaches very large values near the stimulating electrode, our qualitative conclusions remained unchanged.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Strength-interval curves for cardiac tissue predicted using the bidomain model.

INTRODUCTION: Strength-interval curves are predicted for unipolar anodal and cathodal stimulation of cardiac muscle. METHODS AND RESULTS: Cardiac tissue is represented by the bidomain model, and the active properties of the membrane are described by the Beeler-Reuter model. Two successive stimuli (S1 and S2) are delivered through a single extracellular electrode. The S2 threshold is determined as a function of the S1-S2 interval, for anodal and cathodal S2 stimuli with 2-, 5-, 10-, and 20-msec durations. Each of the resulting cathodal and anodal strength-interval curves is divided into two parts: one section corresponding to make stimulation (long intervals) and the other section corresponding to break stimulation (short intervals). Generally, the cathodal strength-interval curves are decreasing functions of interval, except for an anomalous section of the 20-msec duration cathodal curve in the interval range from 310 to 318 msec. At short intervals, the anodal strength-interval curve contains a deep dip, which is more prominent for longer S2 durations. The cathodal threshold is less than the anodal threshold for all intervals except those corresponding to the end of the refractory period. CONCLUSION: The bidomain model predicts complex anodal and cathodal strength-interval curves, with the anodal curve containing a dip (supernormal stimulation). These results resemble the experimental observations of Dekker.

Action Potentials↗

Some factors affecting bubble formation with catheter-mediated defibrillator pulses.

Factors affecting bubble formation during delivery of defibrillator pulses to arrhythmogenic cardiac tissue via a catheter are unknown. We investigated the role of energy, electrode surface area, interelectrode distance, and electrode polarity on bubble formation and on current and voltage waveforms during delivery of damped sinusoidal discharges from a standard defibrillator to anticoagulated bovine blood. Gas composition was studied with mass spectrometry. Defibrillator energy settings were varied between 5 and 360 J. The principal catheter used for study was a Medtronic 6992A lead. Additional electrodes tested included 2, 5, and 10 mm long No. 6F, 7F, and 8F copper electrodes. Interelectrode distances used to assess the effect of anode-cathode spacing were 1, 5, 10, and 20 cm. Bubble volume increased linearly from 0.043 to 0.134 ml per cathodal pulse and from 0.030 to 3.50 ml per anodal pulse as energy settings were increased from 5 to 360 J (r = .99). Typical smooth waveforms for both current and voltage were seen only in the absence of bubbles. The voltage waveform was distorted for each cathodal pulse of 100 J or more and for each anodal pulse of 10 J or more only if bubbles were present. The effect of electrode surface area on bubble formation was tested at a 200 J energy setting and at a 10 cm interelectrode distance with the use of cathodal pulses. Bubble formation varied inversely with electrode surface area (r = .876). Bubble formation, however, varied minimally as interelectrode spacing was changed from 1 to 20 cm. The effect of polarity on bubble formation when the Medtronic 6992A distal electrode and an 8.5 cm disk electrode separated by 10 cm were used was highly significant. For a 200 J pulse, bubble formation with the catheter as anode was 3.30 +/- 0.10 ml and with the catheter as cathode it was 0.070 +/- 0.002 ml (p less than .001). Mass spectrometry of both anodal and cathodal gas samples demonstrated the constituents of the gas bubble to include a variety of gases, which is inconsistent with simple electrolytic production of the bubbles observed. The predominance of nitrogen in either polarity sample suggested that the principal source of the bubble was dissolved air. In summary, bubble formation at an electrode receiving damped sinusoidal outputs from a standard defibrillator does not vary significantly with varying interelectrode distance. However, it is directly proportional to energy and inversely proportional to electrode surface area. Anodal catheter discharges produce considerably more bubbles than do cathodal discharges.(ABSTRACT TRUNCATED AT 400 WORDS)

Catheterization↗

Enhanced oligonucleotide delivery to mouse retinal cells using iontophoresis.

PURPOSE: To study the combination of oligodeoxynucleotides (ODNs) intravitreous injection and saline transpalpebral iontophoresis on the delivery of ODNs to photoreceptors in the newborn rd1/rd1 mice. METHODS: Cathodal or anodal transpalpebral iontophoresis (1.43 mA/cm(2) for 5 min) was applied to eyes of postnatal day 7 (PN7) rd1/rd1 mice immediately before the intravitreous injection of ODNs. The effect of cathodal iontophoresis after ODNs injection was also evaluated. The influence of current intensity (0.5, 1.5, and 2.5 mA) was assayed with cathodal iontophoresis performed prior to ODNs injection. The duration of current-induced facilitation of ODNs delivery to photoreceptors was evaluated for 6 h following iontophoresis. One group of control eyes received cathodal iontophoresis prior to the intravitreous injection of phosphate buffered saline (PBS) or hexachlorofluorescein (Hex). The second control group received ODN or Hex intravitreous injection without iontophoresis. The penetration of fluorescent ODNs in the outer nuclear layer (ONL) was quantified by image analysis of the ONL fluorescence intensity on cryosection microphotographs. Integrity of ODN was assessed using acrylamide gel migration after its extraction from the retina of treated mice. The integrity of retinal structure, 1 and 24 h after iontophoresis, was analyzed using light and electron microscopy. RESULTS: Transpalpebral anodal or cathodal saline iontophoresis enhanced the penetration of ODNs in all retinal layers. Cathodal iontophoresis was more efficient than anodal iontophoresis in enhancing the tissue penetration of the injected ODN. Photoreceptor delivery of ODN was significantly higher when cathodal saline transpalpebral iontophoresis was applied prior than after the injection. The extent of enhanced tissue penetration decreased in parallel to the increased interval between iontophoresis application and the intravitreous injection. Current of 1.5 mA was safe and optimal for the delivery of ODNs to the ONL. One hour after iontophoresis followed by injection, ODN extracted from the retina of treated eyes remained intact. Histology and electron microscopy observations demonstrated that iontophoresis using the optimal parameters did not induce any permanent tissue alterations or structure damage. CONCLUSIONS: Saline transpalpebral iontophoresis facilitates the penetration of injected ODNs in photoreceptors for at least 3 h. This method may be considered for photoreceptor targeted gene therapy.

Animals↗

Evidence implicating descending fibers in self-stimulation of the medial forebrain bundle.

The role of ascending and descending fibers in self-stimulation of the lateral hypothalamus and ventral tegmental area in the rat was assessed by noting whether anodal hyperpolarization of one of these sites could reduce the rewarding effect of stimulating the other site. Strength-duration curves were obtained by psychophysical means, with one of the depth electrodes serving as the cathode and the other as the anode. It was anticipated that at long pulse durations, conduction in some of the fibers stimulated at the cathode would be blocked at the anode. At shorter durations, the anodal hyperpolarization should have dissipated before the arrival of the action potentials triggered by the cathode. Thus, the predicted effect of the block was to bend the strength-duration curves obtained with two depth electrodes upward at long pulse durations, provided that the anode lay between the cathode and the efferent stages of the pathway responsible for the rewarding effect. To control for possible differences in the density of the reward substrate in the lateral hypothalamic and ventral tegmental areas, the strength-duration curves obtained with a given cathode and a depth anode were compared to curves obtained with the same cathode but with an anode consisting of a set of skull screws. It was expected that the concentrated current entering from the depth anode would much more effectively block conduction in the medial forebrain bundle than the diffuse current entering from the large, distant skull screws. The predicted change in the shape of the strength-duration curves was observed only when the ventral tegmental electrode served as the anode and the lateral hypothalamic electrode as the cathode. This is consistent with the notion that in at least some of the neurons responsible for the rewarding effect, action potentials elicited by the lateral hypothalamic electrode had to pass through the ventral tegmental area in order to reach the efferent stages of the reward pathway. In the simplest anatomical arrangement consonant with this view, the somata of these cells lie in the forebrain and give rise to descending axons. As a test of the hypothesis that anodal block was responsible for changing the shape of the strength-duration curve obtained with the ventral tegmental anode, a psychophysical version of the collision test was used to determine whether the tips of the lateral hypothalamic and ventral tegmental electrodes were indeed linked by a common set of reward-related fibers.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Orientation of neurite growth by extracellular electric fields.

Extracellularly applied steady electric fields of 0.1 to 10 V/cm were found to have marked effects on the neurite growth of single dissociated Xenopus neurons in culture: (1) neurites facing the cathode showed accelerated growth, while the growth of those facing the anode was reduced. Neurites growing relatively perpendicular to the field axis were prompted to curve toward the cathode. (2) More neurites appeared to be initiate from the cathodal side of the cell. (3) The number of neurite-bearing neurons per culture and the average neurite length were increased. These effects are absent in cultures treated with electric fields of similar strength but alternating polarity and cannot be attributed either to a gradient of extracellular diffusible substances or to the flow of culture medium produced by the field. The field effects are reversible: (1) removal of the electric field resulted in the loss of neurite orientation in a few hours and (2) reversal of the polarity of the electric field led to a rapid reversal in the neurite orientation. To determine the cellular loci of these field effects, we treated the neurons with a number of pharmacological agents or altered their ionic environments. Incubation with concanavalin A (Con A) was found to abolish these filed effects completely. Since the binding of Con A to the neuronal surface was shown to prevent field-induced accumulation of the Con A receptors toward the cathodal side of these neurons, our finding is accumulation of the Con A receptors toward the cathodal side of these neurons, our finding is consistent with the notion that cathodal accumulation of growth-controlling surface glycoproteins by the field is the underlying mechanism of the field-induced orientation of neurite growth toward the cathode.

Animals↗

Effects of direct current on dog liver: possible mechanisms for tumor electrochemical treatment.

Mechanisms of tumor electrochemical treatment (ECT) were studied using normal dog liver. Five physical and chemical methods were used. Two platinum electrodes were inserted into an anesthetized dog's liver at 3 cm separation. A voltage of 8.5 V direct current (DC) at an average current of 30 mA was applied for 69 min; total charge was 124 coulombs. Concentrations of selected ions near the anode and cathode were measured. The concentrations of Na+ and K+ ions were higher around the cathode, whereas the concentration of Cl- ions was higher around the anode. Water contents and pH were determined near the anode and the cathode at the midpoint between the two electrodes and in an untreated area away from the electrodes. Hydration occurred around the cathode, and dehydration occurred around the anode. The pH values were 2.1 near the anode and 12.9 near the cathode. Spectrophotometric scans of the liver sample extract were obtained, and the released gases were identified by gas chromatography as chlorine at the anode and hydrogen at the cathode. These results indicate that a series of electrochemical reactions take place during ECT. The cell metabolism and its environment are severely disturbed. Both normal and tumor cells are rapidly and completely destroyed in this altered environment. We believe that the above reactions are the ECT mechanisms for treating tumors.

Animals↗

Improved fuel cell and electrode designs for producing electricity from microbial degradation.

A new one-compartment fuel cell was composed of a rubber bunged bottle with a center-inserted anode and a window-mounted cathode containing an internal, proton-permeable porcelain layer. This fuel cell design was less expensive and more practical than the conventional two-compartment system, which requires aeration and a ferricyanide solution in the cathode compartment. Three new electrodes containing bound electron mediators including a Mn(4+)-graphite anode, a neutral red (NR) covalently linked woven graphite anode, and an Fe(3+)-graphite cathode were developed that greatly enhanced electrical energy production (i.e., microbial electron transfer) over conventional graphite electrodes. The potentials of these electrodes measured by cyclic voltametry at pH 7.0 were (in volts): +0.493 (Fe(3+)-graphite); +0.15 (Mn(4+)-graphite); and -0.53 (NR-woven graphite). The maximal electrical productivities obtained with sewage sludge as the biocatalyst and using a Mn(4+)-graphite anode and a Fe(3+)-graphite cathode were 14 mA current, 0.45 V potential, 1,750 mA/m(2) current density, and 788 mW/m(2) of power density. With Escherichia coli as the biocatalyst and using a Mn(4+)-graphite anode and a Fe(3+)-graphite cathode, the maximal electrical productivities obtained were 2.6 mA current, 0.28 V potential, 325 mA/m(2) current density, and 91 mW/m(2) of power density. These results show that the amount of electrical energy produced by microbial fuel cells can be increased 1,000-fold by incorporating electron mediators into graphite electrodes. These results also imply that sewage sludge may contain unique electrophilic microbes that transfer electrons more readily than E. coli and that microbial fuel cells using the new Mn(4+)-graphite anode and Fe(3+)-graphite cathode may have commercial utility for producing low amounts of electrical power needed in remote locations.

Biodegradation, Environmental↗

Ultrastructure of electrically induced osteogenesis in the rabbit medullary canal.

The ultrastructural changes in the medullary canal of the adult male New Zealand white rabbit associated with the trauma of the insertion of an inactive cathode were compared to that associated with electrically induced osteogenesis from an active cathode delivering 20 microA constant direct current. In the vicinity of both an inactive and an active cathode, the medullary canal cellular content was replaced first by polymorphic cells and later by osteoblastic new bone formation. The polymorphic cells always appeared in the immediate vicinity of a capillary or other blood vessel. With time, the new bone formation in the medullary canal surrounding the inactive cathode disappeared, while new formation surrounding the active cathode progressively increased in amount. When the new bone formation in the medullary canal surrounding an inactive cathode disappeared, it was replaced by a network of polymorphic cells. When direct current was then applied to such an inactive electrode, the polymorphic cells were again rapidly replaced by bone. The close association of polymorphic cells with osteoblasts suggests that the former may be a precursor cell of the latter.

Animals↗

History of blood gas analysis. V. Oxygen measurement.

The first biologic use of a platinum cathode for oxygen monitoring was reported in 1938 by Blinks and Skow, who was studying photosynthesis. Their report led to the tissue oxygen studies of Davies, Brink, and Bronk. Clark, by covering cathode and anode with a polyethylene membrane, changed the polarographic cathode from a sensor of oxygen availability by diffusion to a measure of oxygen tension (PO2) in the solution and thereby facilitated an enormous expansion of the study of the respiratory physiology of blood oxygen after 1956. Clark's electrode led to the development of the present commercial blood gas systems that measure pH, carbon dioxide tension (PCO2), and PO2 and calculate many derived variables. Variations on Clark's electrode were designed for in vivo catheter-tip recording; gas phase oxygen monitoring; determining oxygen content of blood by releasing hemoglobin-bound oxygen and measuring PO2; and determining oxygen consumption in cell cultures (thus replacing Warburg manometry). By reducing the cathode diameter, Staub and others eliminated the need for stirring the blood samples. Concurrent research with amperometric or polarographic oxygen measurement led Hersch to develop the means of determining oxygen content by coulometry in large cells that consumed all the injected oxygen. Methods of applying noninsulating, but protein impermeable, membranes to cathodes and of recessing cathodes into glass permitted measurement of PO2 in tissues and fluids with microelectrodes.

Blood Gas Analysis↗

EMG responses in the soleus muscles evoked by unipolar galvanic vestibular stimulation.

This study compared the effects of transmastoid galvanic stimulation with unilateral galvanic stimulation of vestibular afferents. We recorded the effects on soleus EMG occurring at short (SL) and medium (ML) latency, both in normal subjects and in patients with previous unilateral vestibular neurectomy. Unipolar cathodal and anodal stimulation on the same side produced opposite effects for both SL and ML responses. Responses to unilateral cathodal or anodal stimulation were smaller, but otherwise resembled those of transmastoid stimulation with the cathode or the anode placed on the same side, respectively. Unilateral cathodal stimulation resulted in a larger SL response, which occurred at shorter latency than unilateral anodal stimulation. With unipolar stimulation on the side of previous vestibular nerve section, typical SL and ML responses were absent. With stimulation of the intact side, the patients showed smaller SL responses than normal subjects with unilateral stimulation. The larger responses to unilateral cathodal compared to unilateral anodal stimulation are consistent with previous reports that cathodal stimulation produces an increase and anodal a decrease in vestibular nerve firing. The smaller SL responses in the patients may be a consequence of central nervous system reorganization following unilateral vestibular nerve section.

Adult↗

Power generation in fed-batch microbial fuel cells as a function of ionic strength, temperature, and reactor configuration.

Power density, electrode potential, coulombic efficiency, and energy recovery in single-chamber microbial fuel cells (MFCs) were examined as a function of solution ionic strength, electrode spacing and composition, and temperature. Increasing the solution ionic strength from 100 to 400 mM by adding NaCl increased power output from 720 to 1330 mW/m2. Power generation was also increased from 720 to 1210 mW/m2 by decreasing the distance between the anode and cathode from 4to 2 cm. The power increases due to ionic strength and electrode spacing resulted from a decrease in the internal resistance. Power output was also increased by 68% by replacing the cathode (purchased from a manufacturer) with our own carbon cloth cathode containing the same Pt loading. The performance of conventional anaerobic treatment processes, such as anaerobic digestion, are adversely affected by temperatures below 30 degrees C. However, decreasing the temperature from 32 to 20 degrees C reduced power output by only 9%, primarily as a result of the reduction of the cathode potential. Coulombic efficiencies and overall energy recovery varied as a function of operating conditions, but were a maximum of 61.4 and 15.1% (operating conditions of 32 degrees C, carbon paper cathode, and the solution amended with 300 mM NaCl). These results, which demonstrate that power densities can be increased to over 1 W/m2 by changing the operating conditions or electrode spacing, should lead to further improvements in power generation and energy recovery in single-chamber, air-cathode MFCs.

Bacteria, Anaerobic↗