Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Accuracies of ancestral amino acid sequences inferred by the parsimony, likelihood, and distance methods.

Information about protein sequences of ancestral organisms is important for identifying critical amino acid substitutions that have caused the functional change of proteins in evolution. Using computer simulation, we studied the accuracy of ancestral amino acids inferred by two currently available methods (maximum-parsimony [MP] and maximum-likelihood [ML] methods) in addition to a distance method, which was newly developed in this paper. All three methods give reliable inference when the divergence of amino acid sequences is low. When the extent of sequence divergence is high, however, the ML and distance methods give more accurate results than the MP method, particularly when the phylogenetic tree includes long branches. The accuracy of inferred ancestral amino acids does not change very much when a few present-day sequences are added or eliminated. When an incorrect model of amino acid substitution is used for the ML and distance methods, the accuracy decreases, but it is still higher than that for the MP method. When the tree topology used is partially incorrect, the accuracy in the correct part of the tree is virtually unaffected. The posterior probability of inferred ancestral amino acids computed by the ML and distance methods is an unbiased estimate of the true probability when a correct substitution model is used but may become an overestimate when a simpler model is used.

Amino Acid Sequence↗

[Accuracy of fluoroscopic navigation of pedicle screws. CT-based evaluation of bone screw placement].

While the advantages of C-arm navigation in computer-assisted spine surgery are obvious, the accuracy of pedicle screw placement with virtual fluoroscopy still needs to be verified. The C-arm-based ION system (Medtronic Sofamor Danek) was used to navigate pedicle screw insertion in patients undergoing spinal surgery for various conditions. In a prospective study, a total of 160 screws were inserted in the first 30 consecutive patients since introduction of the system at our institution: 54 at the thoracic spine (highest level: TH4) and 106 at the lumbar spine. Computed tomography (CT) scans were performed postoperatively by two independent radiologists to control the accuracy of screw placement at the level of the pedicles after reconstruction of axial images according to Laine et al. The comparison of the calculated accuracy rate of pedicle screw placement using virtual fluoroscopy with reported results achieved with CT-based navigation shows similar results for virtual fluoroscopy and a remarkable increase of accuracy in comparison to reports on conventional pedicle screw placement.

Bone Screws↗

Pressure measurement evaluation and accuracy validation: the Gabarith test.

OBJECTIVE: The dynamic distortion introduced by manometric systems has been known for many years, with several methods developed to describe and quantify the degree of distortion. We developed the Gabarith as a technique to describe more accurately, and yet more simply, the dynamic accuracy of the chain of monitoring. SETTING: A pressure monitoring system transforms some input signal, i.e. the actual pressure waveform present in the artery, into some other shape of waveform, i.e. the waveform displayed on the patient monitor. This transformation is characterized by the transfer function of the total system. A complete technique to define the transfer function is to measure the response directly at many different frequencies and combine them to produce the dynamic response plot. METHOD: We described the dynamic response of a monitoring chain and we simplified the communication of this dynamic response to users by developing the Gabarith, as a tolerance envelope based on the frequency content of typical pressure waveforms. If a given monitoring chain's dynamic response (including a catheter, a pressure kit and a monitor) can be shown to fall within that tolerance envelope, the chain will provide adequate dynamic accuracy. CONCLUSION: "Gabarith tested" means that a pressure kit, in combination with a catheter and a monitor, has had its frequency response function measured and that the function falls within a tolerance band for dynamic accuracy. Passing a Gabarith means that a given level of accuracy will be reached when using the sets which have passed the corresponding test.

Blood Pressure Determination↗

Accuracy and precision of a new portable ultrasound scanner, the BME-150A, in residual urine volume measurement: a comparison with the BladderScan BVI 3000.

The objective of the study was to determine the relative accuracy of a new portable ultrasound unit, BME-150A, and the BladderScan BVI 3000, as assessed in comparison with the catheterized residual urine volume. We used both of these machines to prospectively measure the residual urine volumes of 89 patients (40 men and 49 women) who were undergoing urodynamic studies. The ultrasound measurements were compared with the post-scan bladder volumes obtained by catheterization in the same patients. The ultrasounds were followed immediately (within 5 min) by in-and-out catheterizations while the patients were in a supine position. There were a total of 116 paired measurements made. The BME-150A and the BVI 3000 demonstrated a correlation with the residual volume of 0.92 and 0.94, and a mean difference from the true residual volume of 7.8 and 3.6 ml, respectively. Intraclass correlation coefficients for the accuracy of the two bladder scans were 0.90 for BME-150A and 0.95 for BVI 3000. The difference of accuracy between the two models was not significant (p = 0.2421). There were six cases in which a follow-up evaluation of falsely elevated post-void residual urine volume measurements on the ultrasound studies resulted in comparatively low catheterized volumes, with a range of differences from 66 to 275.5 ml. These cases were diagnosed with an ovarian cyst, uterine myoma, or uterine adenomyosis on pelvic ultrasonography. The accuracy of the BME-150A is comparable to that of the BVI 3000 in estimating the true residual urine volumes and is sufficient enough for us to recommend its use as an alternative to catheterization.

Adolescent↗

Speed-accuracy of saccades, vergence and combined eye movements in children with vertigo.

Vergence abnormalities could lead to inappropriate vestibulo-ocular reflex (VOR), causing vertigo and imbalance (Brandt 1999). Indeed, a recent study by Anoh-Tanon et al. (2000) reported the existence of a population of children with symptoms of vertigo in the absence of vestibular dysfunction but with abnormal vergence findings in orthoptic tests. The purpose of this study was to examine in such children the accuracy, duration and mean velocity of vergence and saccades; additionally, for a few subjects, the effect of orthoptic vergence training on these parameters was also investigated. LEDs were used to stimulate saccades, pure vergence along the median plane and combined saccade-vergence movements. Movements from both eyes were recorded with a photoelectric device (Bouis). The results show that children with vertigo perform saccades as normal subjects of comparable age. In contrast, vergence, particularly convergence, shows abnormalities: poor accuracy, long duration and low speed. During combined movements, the well known reciprocal interaction between the saccade and the vergence is present only for saccades combined with divergence; for saccades combined with convergence such interaction is abnormal: the saccade is slowed down by the convergence but the convergence is not accelerated by the saccade. Orthoptic training improves significantly the accuracy of all eye movements; such improvement was significant for all types of eye movements except for divergence (pure and combined). Furthermore, convergence remains abnormal and the lack of acceleration by the saccade persists. These specific convergence deficits could be of both subcortical and cortical origin. Orthoptic training improves the accuracy presumably via visual attentional mechanisms, but cannot completely override deficits related to subcortical deficiencies.

Adolescent↗

Effects of accuracy constraints on reach-to-grasp movements in cerebellar patients.

Reach-to-grasp movements of patients with pathology restricted to the cerebellum were compared with those of normal controls. Two types of paradigms with different accuracy constraints were used to examine whether cerebellar impairment disrupts the stereotypic relationship between arm transport and grip aperture and whether the variability of this relationship is altered when greater accuracy is required. The movements were made to either a vertical dowel or to a cross bar of a small cross. All subjects were asked to reach for either target at a fast but comfortable speed, grasp the object between the index finger and thumb, and lift it a short distance off the table. In terms of the relationship between arm transport and grip aperture, the control subjects showed a high consistency in grip aperture and wrist velocity profiles from trial to trial for movements to both the dowel and the cross. The relationship between the maximum velocity of the wrist and the time at which grip aperture was maximal during the reach was highly consistent throughout the experiment. In contrast, the time of maximum grip aperture and maximum wrist velocity of the cerebellar patients was quite variable from trial to trial, and the relationship of these measurements also varied considerably. These abnormalities were present regardless of the accuracy requirement. In addition, the cerebellar patients required a significantly longer time to grasp and lift the objects than the control subjects. Furthermore, the patients exhibited a greater grip aperture during reach than the controls. These data indicate that the cerebellum contributes substantially to the coordination of movements required to perform reach-to-grasp movements. Specifically, the cerebellum is critical for executing this behavior with a consistent, well-timed relationship between the transport and grasp components. This contribution is apparent even when accuracy demands are minimal.

Adult↗

Contribution of tactile information to accuracy in pointing movements.

We examined the contribution of tactile cues to accuracy during point-to-point movements. We used a task in which the experimenter guided either the left or right hand of the subject to a spatial location during the reference movement. During the subsequent test movement subjects were asked to point with the right hand to the remembered location without vision. Subjects contacted the target with their fingertip either during the reference movement, both the reference and test movements, or neither movement (i.e., the fingertip was held above the target surface). To differentiate between the contribution of tactile and proximal deep pressure information, the left index finger was anesthetized in a subsequent experiment. When subjects contacted the surface with the fingertip of the reference hand alone, error in movement direction decreased. When subjects made fingertip contact during the reference and test movements, gain error also decreased. Anesthesia of the fingertip degraded accuracy, suggesting that tactile information, independent of information from proximal deep pressure receptors, influenced movement accuracy. Thus, tactile information contributed to accuracy in pointing movements. We suggest that forces at fingertip contact may provide information regarding the orientation of the finger and forearm in space, which is used to replicate final arm posture. In addition, tactile cues at the beginning and end of the movement may be used to scale movement amplitude.

Adult↗

Effects of electrocardiography and chest radiography on the accuracy of preliminary diagnosis of common congenital cardiac defects.

The objective of this study was to compare the accuracy of the expert clinical examination for certain common cardiac defects with and without electrocardiogram (EKG) and chest radiogram (x-ray). The design of the study was a prospective, blinded comparison of diagnostic accuracy of the expert examination with and without EKG and x-ray, using echocardiography as the diagnostic standard. The setting of the study was the pediatric cardiology outpatient department. There were 749 outpatients with heart murmur under 21 years of age without prior echocardiography or pediatric cardiology consultation. The intervention was echocardiography as clinically indicated for evaluation of heart murmur of uncertain cause. Measurements were carried out using the incorporation of EKG and x-ray into multiple linear regression models to assess independent associations, if any, with the accuracy of clinical examination. Results were reported as the presence or absence of independent significant impact of availability of EKG and x-ray on examiner's diagnostic accuracy for innocent murmur, ventricular septal defect (VSD), pulmonary stenosis (PS), aortic valve disease, atrial septal defect (ASD), and patent ductus arteriosus. EKG enhanced detection of ASD and may have helped detect PS. X-ray enhanced detection of intermediate to large VSD. X-ray and EKG were otherwise without demonstrable independent advantage for defect-specific diagnosis. Routine use of one or both of these tests in the initial evaluation of heart murmur in the pediatric cardiology clinic should remain an option.

Child↗

The accuracy of chest radiographs in the detection of congenital heart disease and in the diagnosis of specific congenital cardiac lesions.

BACKGROUND: Congenital heart disease (CHD) is a significant cause of morbidity and mortality in pediatric patients. Traditional teaching holds that specific types of CHD can be diagnosed on the chest radiograph (CXR) through pattern recognition. OBJECTIVE: To determine the accuracy of radiologists in detecting CHD on the CXR. MATERIALS AND METHODS: This study was a blinded retrospective review of chest radiographs from 281 patients (<12 years) by five pediatric radiologists from three institutions. Thirteen groups were evaluated that included 12 categories of CHD and a control group of patients without heart disease. Radiographs were assessed for heart size, heart and mediastinal shape and vascularity. Clinical information, angiography, echocardiograms and surgery were used as the gold standard for definitive diagnosis. RESULTS: The average accuracy of the five readers in distinguishing normal from CHD patients was 78% (range of 72% to 82%). The overall measure of accuracy in distinguishing specific congenital cardiac lesions among 13 groups of patients was 71% (range of 63% to 79%). CONCLUSION: CXR alone is not diagnostic of specific cardiac lesions, with a low accuracy of only 71%. We believe that less emphasis should be placed on the use of radiographs alone in diagnosing specific congenital cardiac lesions.

Child↗

Accuracy of ultrasonography for the diagnosis of intussusception in infants in Vietnam.

BACKGROUND: Intussusception (IS) is the most common cause of acute bowel obstruction in infants and young children. Ultrasonography is being increasingly used as the primary investigation for the diagnosis of IS and to guide air or hydrostatic enema reduction. However the accuracy of ultrasonography outside tertiary care settings in developed countries has not been assessed, particularly in Asia where the incidence of IS based on sonographic diagnosis has been reported as the highest in the world. OBJECTIVE: The aim of this study was to evaluate the accuracy of ultrasonography in the diagnosis of acute IS in infants less than 2 years of age in a paediatric hospital in Vietnam. MATERIALS AND METHODS: A prospective study was conducted at the National Hospital for Paediatrics, Hanoi, Vietnam, over a 14-month period recruiting patients <2 years of age with IS. Abdominal ultrasonography was performed on each patient and the accuracy of the diagnosis was evaluated against the final diagnosis provided by air enema and/or surgery. RESULTS: A total of 640 infants <2 years of age presented with clinical symptoms and signs of IS. The diagnosis was confirmed in 533 patients via air enema or surgery. Abdominal ultrasonography was 97.5% (466/478) sensitive and 99% (106/107) specific in the detection of IS. CONCLUSION: Ultrasonography is an accurate, safe and valuable clinical tool in the diagnosis of IS. The use of ultrasonography as a primary investigation for patients with suspected IS prevents unnecessary radiological or surgical procedures being performed, and reduces radiation exposure while maintaining a high level of diagnostic accuracy. These results validate the use of ultrasonography for the diagnosis of IS in a developing country setting.

Female↗

Accuracy of plain films, and the effect of experience, in the assessment of ankle effusions.

OBJECTIVE: To investigate the accuracy of plain radiographs, and the effect of observer experience, in the assessment of ankle effusions compared with an MRI gold standard. DESIGN AND PATIENTS: Anteroposterior (AP) and lateral radiographs of the ankle of 39 patients were evaluated by four observers, ranging from first-year radiology resident to an attending musculoskeletal radiologist. Observers independently graded the lateral films from 0 to 5 at one sitting, and the AP films at a second sitting. All patients had an MRI scan performed within 48 h of the ankle radiographs, on which distention of the anterior recess was used as the gold standard for an effusion. RESULTS: Lateral radiographs had variable sensitivity (range 17-63%), but specificity (81-94%) was usually high. AP radiographs similarly had variable sensitivity (15-55%), but their specificity (63-75%) was surprisingly good. Overall, sensitivity and specificity were inversely proportional and more related to individual variability than experience (observer 1, 53% and 81%; observer 2, 17% and 94%; observer 3, 63% and 88%; observer 4, 21% and 94%); however, individual sensitivity and specificity were consistent between AP and lateral radiographs (observer 1, 53% and 81%, 50% and 65%; observer 2, 17% and 94%, 15% and 75%), observer 3, 63% and 88%, 55% and 63%; observer 4, 21% and 94%, 25% and 70%). Positive predictive value was reasonably good for lateral radiographs (range 75-86%); however, it was fairly low for AP radiographs (38-61%). Negative predictive value was low for both lateral (50-67%) and AP (47-58%) radiographs. Accuracy was low for both AP (45-59%) and lateral (53-74%) radiographs. As expected, individual accuracy was consistently higher for lateral radiographs than for AP radiographs (observer 1, 65% and 58%; observer 2, 53% and 45%; observer 3, 74% and 59%; observer 4, 54% and 48%). CONCLUSIONS: For the diagnosis of ankle effusions the overall accuracy of radiographs was surprisingly low. Quite surprisingly, the diagnosis of effusions on AP radiographs was not much poorer than on lateral films. Results, however, varied little with experience and training.

Adult↗

PET-MR image fusion in soft tissue sarcoma: accuracy, reliability and practicality of interactive point-based and automated mutual information techniques.

The fusion of functional positron emission tomography (PET) data with anatomical magnetic resonance (MR) or computed tomography images, using a variety of interactive and automated techniques, is becoming commonplace, with the technique of choice dependent on the specific application. The case of PET-MR image fusion in soft tissue is complicated by a lack of conspicuous anatomical features and deviation from the rigid-body model. Here we compare a point-based external marker technique with an automated mutual information algorithm and discuss the practicality, reliability and accuracy of each when applied to the study of soft tissue sarcoma. Ten subjects with suspected sarcoma in the knee, thigh, groin, flank or back underwent MR and PET scanning after the attachment of nine external fiducial markers. In the assessment of the point-based technique, three error measures were considered: fiducial localisation error (FLE), fiducial registration error (FRE) and target registration error (TRE). FLE, which represents the accuracy with which the fiducial points can be located, is related to the FRE minimised by the registration algorithm. The registration accuracy is best characterised by the TRE, which is the distance between corresponding points in each image space after registration. In the absence of salient features within the target volume, the TRE can be measured at fiducials excluded from the registration process. To assess the mutual information technique, PET data, acquired after physically removing the markers, were reconstructed in a variety of ways and registered with MR. Having applied the transform suggested by the algorithm to the PET scan acquired before the markers were removed, the residual distance between PET and MR marker-pairs could be measured. The manual point-based technique yielded the best results (RMS TRE =8.3 mm, max =22.4 mm, min =1.7 mm), performing better than the automated algorithm (RMS TRE =20.0 mm, max =30.5 mm, min =7.7 mm) when registering filtered back-projection PET images to MR. Image reconstruction with an iterative algorithm or registration of a composite emission-transmission image did not improve the overall accuracy of the registration process. We have demonstrated that, in this application, point-based PET-MR registration using external markers is practical, reliable and accurate to within approximately 5 mm towards the fiducial centroid. The automated algorithm did not perform as reliably or as accurately.

Fluorodeoxyglucose F18↗

A new approach for improving diagnostic accuracy in Alzheimer's disease and frontal lobe dementia utilising the intrinsic properties of the SPET dataset.

Alzheimer's disease (AD) and frontal lobe dementia (FLD) show characteristic patterns of regional cerebral blood flow (rCBF). However, these patterns may overlap with those observed in the aging brain in elderly normal individuals. The aim of this study was to develop a new method for better classification and recognition of AD and FLD cases as compared with normal controls. Forty-six patients with AD, 7 patients with FLD and 34 normal controls (CTR) were included in the study. rCBF was assessed by technetium-99m hexamethylpropylene amine oxime and a three-headed single-photon emission tomography (SPET) camera. A brain atlas was used to define volumes of interest (VOIs) corresponding to the brain lobes. In addition to conventional image processing methods, based on count density/voxel, the new approach also analysed other intrinsic properties of the data by means of gradient computation steps. Hereby, five factors were assessed and tested separately: the mean count density/voxel and its histogram, the mean gradient and its histogram, and the gradient angle co-occurrence matrix. A feature vector concatenating single features was also created and tested. Preliminary feature discrimination was performed using a two-sided t-test and a K-means clustering was then used to classify the image sets into categories. Finally, five-dimensional co-occurrence matrices combining the different intrinsic properties were computed for each VOI, and their ability to recognise the group to which each individual scan belonged was investigated. For correct classification of the AD-CTR groups, the gradient histogram in the parieto-temporal lobes was the most useful single feature (accuracy 91%). FLD and CTR were better classified by the count density/voxel histogram (frontal and occipital lobes) and by the mean gradient (frontal, temporal and parietal lobes, accuracy 98%). For AD and FLD the count density/voxel histogram in the frontal, parietal and occipital lobes classified the groups with the highest accuracy (85%). The concatenated joint feature correctly classified 96% of the AD-CTR, 98% of the FLD-CTR and 94% of the AD-FLD cases. 5D co-occurrence matrices correctly recognised 98% of the AD-CTR cases, 100% of the FLD-CTR cases and 98% of the AD-FLD cases. The proposed approach classified and diagnosed AD and FLD patients with higher accuracy than conventional analytical methods used for rCBF-SPET. This was achieved by extracting from the SPET data the intrinsic information content in each of the selected VOIs.

Aged↗

Accuracy of MRI in characterization of soft tissue tumors and tumor-like lesions. A prospective study in 548 patients.

The purpose of our study was to assess prospectively the value of MRI in characterization of soft tissue tumors (STT) and soft tissue tumor-like lesions in a multi-institutional setting by a group of experts. The material consisted of 548 untreated and proven STT or tumor-like lesions originating from a multi-institutional database of STT in which 930 consecutive patients with STT examined by MRI were registered between 1 January 2001 and 28 April 2003. Based on MRI findings, a suitably ordered differential diagnosis was made in consensus by two radiologists (J.L.M.A.G and A.M.D.S). MRI diagnoses were compared with histology results (455 cases, 83%) and/or 6-month follow-up (93 cases, 17%) as reference standards. The correlation between the MRI and histological diagnosis and between the radiological and histological phenotype were statistically determined. One hundred twenty-three patients presented with a malignant STT; 425 patients presented with a benign one. Concerning differentiation between malignant and benign lesions (dignity), a sensitivity of 93%, specificity of 82%, negative predictive value (NPV) of 98% and positive predictive value (PPV) of 60% with accuracy of 85% were obtained. Concerning phenotype characterization, if only the first MRI diagnosis was taken into account, a sensitivity of 67%, specificity of 98%, NPV of 98%, PPV of 70% and accuracy of 96% were obtained. For benign lesions, sensitivity of 75%, specificity of 98%, NPV of 98%, PPV of 76% and accuracy of 97% were obtained. The phenotype's definition of malignant STT had a sensitivity of 37%, a specificity of 96%, NPV of 96%, PPV of 40% and an accuracy of 92%. A correct diagnosis compared with histological assessment was proposed in 227(50%) of the 455 histologically confirmed cases. Despite non-quantified MR parameter evaluation, the results of our prospective study were better than those reported in previous studies and demonstrated the need for a centralized approach to such rare pathology.

Adolescent↗

Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting.

Coronary Restenosis↗

MR arthrography of traumatic anterior shoulder lesions showed modest reproducibility and accuracy when evaluated under clinical circumstances.

INTRODUCTION: We examined the reproducibility and accuracy of high-field MRA in traumatic anterior shoulder instability under conditions resembling clinical practice and assessed the influence of observer experience. MATERIALS AND METHODS: Two radiologists with different experience levels evaluated 61 MRAs. Assessment was independent, blinded and non-sequential. For 40 MRAs, surgical reports were available to assess diagnosis accuracy and influence of observer experience. The assessed lesions were cuff lesions, Hill-Sachs lesions, bony and classic Bankart lesions, greater humeral tuberosity fractures, SLAP lesions and joint capsule lesions. Reproducibility was quantified using kappa coefficients. Accuracy was evaluated with sensitivity and specificity rates, positive and negative predictive values. Differences in the percentage of correctly diagnosed MRAs between the radiologists were tested using McNemar's test for paired proportions. RESULTS: Inter-observer k-values ranged from 0.03 for joint capsule lesions to 0.45 for humeral head lesions. The overall kappa was 0.21 (95% CI; 0.12-0.30). We also observed markedly lower sensitivity and specificity rates than those reported in the literature for most lesions. The more experienced radiologist correctly diagnosed 78.9% of all lesions compared to 65.4% for the less experienced radiologist (P < 0.001; McNemar's test). CONCLUSION: MRA-interpretations of traumatic anterior shoulder instability should be regarded with caution in clinical practice. The experience level of radiologists can affect reproducibility and accuracy.

Adolescent↗

Speed-accuracy modulation in case of conflict: the roles of activation and inhibition.

This study investigated how the speed-accuracy balance is modulated by changes in the time course of motor activation and inhibition of a primed response. Responses and event-related brain potentials were recorded in a paradigm in which the first stimulus indicated the correct response with 80% validity. The remaining 20% of the trials required no response (no-go) or a response opposite to the cued hand (change trials). Subjects were instructed either to balance speed and accuracy or to emphasize speed at the cost of accuracy. Analyses of error patterns, reaction time distributions and brain potentials show that subjects can modulate the amount of activation of the primed response. More surprisingly, the engagement of inhibition of the response also varied with the speed-accuracy instruction. The results are consistent with a model where the frontothalamic loop actively controls both the activation and the inhibition of responses, depending on the current task requirements.

Adult↗

The accuracy of voiding urosonography in detecting vesico-ureteral reflux: a summary of existing data.

UNLABELLED: The primary objective of this review was to assess the diagnostic accuracy of voiding urosonography (VUS) in detecting reflux (VUR). As a secondary objective, the reported technical suggestions and diagnostic mistakes were shown to improve the examination protocol and provide the most accurate results. Using a Medline Database search, the published articles comparing the grey-scale (GS) or colour-Doppler (CD) VUS with voiding cystourethrography (VCUG) as the gold standard were selected. Articles were excluded when data were not sufficient to construct 2x2 tables or when the gold standard was different from VCUG. For the analyses of diagnostic accuracy values, 95% confidence intervals were given. Agreements in the results of GSVUS and VCUG and in those of CDVUS and VCUG were determined by Kappa statistics. GSVUS and CDVUS were compared for diagnostic accuracy by the McNemar test. Results showed that the range of GSVUS sensitivity and specificity in detecting VUR was 69%-100% and 86%-97%, respectively. The agreement between GSVUS and VCUG diagnoses ranged from 90% to 97% (K score range 0.61-0.92; P<0.001). The range of CDVUS sensitivity and specificity in detecting VUR was 93%-100% and 86%-93%, respectively. The agreement between CDVUS and VCUG diagnoses ranged from 89% to 96% (K score range 0.77-0.91; P<0.001). One study comparing both VUS modalities with VCUG in the same group of patients, showed that the diagnostic accuracy of CDVUS was significantly higher than that of GSVUS (96% versus 90% of cases correctly classified; McNemar chi squared =4; P<0.05). CONCLUSION: the existing data indicate that false-negative voiding urosonographic diagnoses (8%-31%) and underestimated reflux grading cases using the same technique are related to anatomical conditions, patient cooperation and contrast medium administration. False-positive (3%-14%) and overestimated reflux grading cases using voiding urosonography could be correctly assessed cases. The intermittent nature of vesico-ureteral reflux is better detected by a technique employing a prolonged observation time, such as voiding urosonography. This might question the current role of voiding cystourethrography in the investigation of reflux.

Chi-Square Distribution↗