Continuous mass spectrographic measurement of halothane partial pressure in blood.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVES: The paO(2) and AaDO(2) are routinely measured for evaluating pulmonary gas exchange. The normal value of the AaDO(2) amounts 10 mmHg when breathing atmospheric air and is said to increase with rising FIO(2). This increase is discussed controversially. One possible reason for incongruities in AaDO(2) measurement may be the impact of so called preanalytical errors during paO(2) measurement, which are often neglected. Therefore, the aim of this study was to evaluate the relevance of preanalytical errors on the AaDO(2) under hyperoxic conditions. METHODS: Arterial blood gas analysis was performed on twenty patients without known pulmonary disease after tracheal intubation and 30 min of ventilation with pure oxygen. All preanalytical paO(2) errors (sampling technique, transport and storage of samples, aspirated air bubbles) were assessed and all paO(2) measurements were corrected by applying respective predetermined correction factors. Calculation of the AaDO(2) was performed with corrected and uncorrected paO(2) values. RESULTS: The average amount of the AaDO(2) under ventilation with FIO(2)=1.0 was 118.9+/-41.1 mmHg, calculated from uncorrected paO(2) values, and 13.4+/-7.5 mmHg calculated from paO(2) values corrected for preanalytical errors, respectively. CONCLUSION: The present results show that the assumption of an increasing AaDO(2) with rising FIO(2) is questionable. It could be proved that neglecting preanalytical paO(2) errors leads to a significant overestimation of the AaDO(2). The consequence would be a misinterpretation of the patient's condition in relation to a reduced pulmonary gas exchange, which should in fact be attributed solely to the preanalytical errors.
UNLABELLED: We investigated the effects of ultrapurified polymerized bovine hemoglobin (HBOC-201) on skeletal muscle tissue oxygen tension when applied before establishment of a nearly complete arterial stenosis. METHODS: Twelve foxhounds were anaesthetized IV and mechanically ventilated with 30% oxygen in air. Catheters were inserted into the right femoral artery and vein for measurements of haemodynamic parameters and blood-gas sampling. Arterial blood flow of the left popliteal artery was measured by an electromagnetic flow probe. Skeletal muscle tissue oxygen tension (tpo2) was measured in the left gastrocnemic muscle using a stepwise-driven polarographic needle probe, creating histograms from 200 single tpO2 measurements. Following isovolaemic haemodilution with Ringer's solution to a target haematocrit of 20%, the animals were randomly assigned to receive either 200 ml of predonated fresh blood (group 1) or 200 ml of HBOC-201 (MW 32,000-500,000; Hb 13 +/- 1 g-dl-1, group 2). After a 15-min stabilization period, a 95% artificial stenosis of the left popliteal artery was established. While animals of group 1 received two applications of 200 ml 6% hetastarch (HES, 200,000; 0.5), animals of group 2 received 200 ml Ringer's solution 45 and 75 min after establishment of the arterial stenosis, respectively. Variables were measured at baseline, after haemodilution and application of the respective compound, and 30, 60 and 90 min after establishment of the stenosis. RESULTS: Demographic data, muscle temperature and arterial blood gases did not differ between groups. With the exception of a higher mean pulmonary artery pressure in HBOC-201-treated animals, haemodynamics did not differ between groups. In both groups oxygen delivery and oxygen consumption of the muscle decreased in parallel to the decreasing blood flow during arterial stenosis. In contrast, oxygen extraction ratio increased after infusion of HBOC-201 and remained unchanged during stenosis (P < 0.05). In group 1, the tpO2 decreased during stenosis when compared to baseline (P < 0.001) and remained decreased after administration of HES. In contrast, administration of 200 ml of HBOC-201 before establishment of the arterial stenosis sustained the tpO2 values at nearly baseline levels during stenosis. Skeletal muscle tissue oxygen tension was higher after HBOC-201 infusion during stenosis when compared to HES infusion (P < 0.001). CONCLUSION: These data suggest that haemoglobin solutions can reach poststenotic tissues. The increased oxygen extraction after application of HBOC-201 is associated with improved skeletal muscle oxygen tension during severe arterial stenosis.
UNLABELLED: The principle of, "selective shunting" during carotid endarterectomy requires a special concept to monitor neuronal function. The valence of the oxymetric methods, "near-infrared" spectroscopy (NIRS) and conjunctival oxygen tension (pcjO2) was determined with the reference method somatosensory evoked potentials (SEP). METHODS: In 41 patients undergoing reconstructive surgery on the internal carotid artery, recordings of the different methods were obtained under control, during carotid occlusion and during reperfusion. Cerebral ischemia was assumed if a complete loss of SEP appeared and an intraluminal shunt was placed. Conjunctival oxygen tension was measured continuously and simultaneously on the ipsi- and contralateral eye. RESULTS: In comparison to the reference method (SEP) the sensitivity and specificity of NIRS was 80% and 94%, respectively. The occlusion induced reduction of NIRS appeared 6.5 +/- 3.2 min earlier than the corresponding loss of SEP. Biocular determination of conjunctival oxygen tension was not able to detect hypoperfusion dependent ischemia during carotid occlusion. CONCLUSION: During carotid endarterectomy the measurement of conjunctival oxygen tension is not useful to detect cerebral ischemia. The use of NIRS as a single neuronal monitor is not appropriate to perform, "selective shunting". In contrast to SEP, however, NIRS is characterized by its rapid changes immediately following carotid occlusion. This non invasive method is likely to complete the standard method SEP in a modified monitoring concept of neuronal function during carotid endarterectomy.
A new measuring system for the determination of the vapour pressure of single compounds in mixtures is introduced. A coupling system consisting of a quadrupol mass spectrometer and a vapour pressure balance was used for these measurements. Some calibration measurements and investigations of mixtures are discussed.
PURPOSE: To correlate the jugular bulb oxygen saturation (SjvO2) and brain tissue oxygen pressure (PbtO2) during carbon dioxide (CO2) and oxygen (O2) reactivity tests in severely head-injured patients. METHODS AND RESULTS: In nine patients (7 men, 2 women, age: 26 +/- 6.5 years, GCS of 6.5 +/- 2.9), a polarographic microcatheter (Clark-type) was inserted into nonlesioned white matter (frontal lobe). PbtO2 and SjvO2 were monitored simultaneously and cerebral vasoreactivity to CO2 and O2 was tested on days three, five and seven after injury. Simultaneous measurements of vasoreactivity by transcranial Doppler (TCD) were undertaken. A total of twenty-one CO2 and O2 reactivity tests were performed. Critical values of PbtO2 (< 15 mm Hg) during induced hyperventilation could be observed four times in two patients. High PbtO2 values up to 80 mm Hg were observed during hyperoxygenation (FiO2 100%). CO2 vasoreactivity by means of PbtO2 was absent in four tests in which measurements by TCD showed intact responses. A stronger correlation between SjvO2 and PbtO2 during the O2 reactivity tests was observed (r = 0.6, p < 0.001), in comparison to values obtained during the CO2 reactivity tests (r = 0.33, p < 0.001). In addition, there was no statistically significant correlation (r = 0.22, p = 0.26) between CO2 reactivity values measured by TCD (4.5 +/- 5.7%) and PbtO2 (3 +/- 2.8%). CONCLUSIONS: Correlation between SjvO2 and PbtO2 during CO2 reactivity test is low, even if significant differences between normo- and hyperventilation values are present. In comparison to SjvO2, monitoring of PbtO2 might more accurately detect possible focal ischaemic events during rapidly induced hyperventilation in severely head-injured patients. The CO2 vasoreactivity by means of changes in Vm MCA seems to be higher in comparison to changes of PbtO2. These observations lead to the hypothesis that vasoreactivity measured by TCD overestimates the cerebrovascular response to CO2.
BACKGROUND: According to Schmelzeisen et al. (1996), the failure rate for microvascular free flaps is 5%. While surface tissue oxygenation can be assessed clinically, if necessary by a puncture, the oxygen supply to deeper areas mostly cannot be checked. We therefore wished to find whether measurement of tissue pO(2) would prove to be an objective and practical technique that could be used for continuous and accurate intra- and postoperative evaluation of flap perfusion. MATERIAL AND METHODS: A Clark-type microcatheter was used intra- and postoperatively to monitor tissue pO(2) in 5 pedicled pectoralis major flaps and 32 free revascularized flaps (9 jejunal flaps, 5 latissimus dorsi flaps, 6 radial forearm flaps and 12 scapular flaps). RESULTS: The mean values for tissue pO(2) were significantly lower in pedicle grafts than in free revascularized flaps. Within in each flap group the pO(2) values measured did not vary significantly over an observation period of up to 77.2 h after transplantation. CONCLUSIONS: Continuous measurement of tissue pO(2) by means of a Clark-type microcatheter combined with clinical examination constitutes a reliable method of monitoring tissue oxygenation in pedicle grafts and free revascularized flaps during the intra- and postoperative phases. Analysis of small and of wide fluctuations in pO(2) values may help in the diagnosis of early arterial and venous obstructions in flaps and may in the future result in new insights into the tissue oxygenation in surgical flaps allowing some alleviation of the problems currently experienced in clinical monitoring.
Explore the source record for details and available documents.
NADPH- and iron-dependent lipid peroxidation of rat heart and liver microsomes was measured in the presence and absence of adriamycin. Lipid peroxidation was enhanced by adriamycin when incubated in air and was increased as the pO2 was lowered, to a maximum of 3-4 times the aerobic level at a pO2 of approx. 4 mm Hg. Fe-ADP, Fe-ATP and ferritin were able to catalyse adriamycin-dependent peroxidation of microsomes under low pO2. Superoxide dismutase and catalase had minimal effect. These results indicate that adriamycin-dependent lipid peroxidation is favoured by the low O2 concentration that exist in active muscle cells and suggest that ferritin could provide the iron catalyst for the reaction.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Scale formation in industrial or domestic installations is still an important economic problem. The existence of a metastable domain for calcium carbonate supersaturated solutions and its breakdown are observed under conditions rarely well defined. In most cases it is the pH rise caused by the carbon dioxide loss that involves calcium carbonate precipitation. Before studying this problem, we suggest in this first part, a new model for the evolution of the calcocarbonic system that takes into account the hydrated forms of CaCO3: CaCO3 amorphous, CaCO3 x 6H2O (ikaite) and CaCO3 x H2O (monohydrate). According to this model, the precipitation of any one of these hydrated forms could be responsible for the breakdown of the metastable state. After this first step, the solids evolve into dehydrated forms. At first, the metastable domain spread of the calcium carbonate supersaturated solutions was studied by the elaboration of computer programs in which the formation of CaCO3(0)(aq) ion pairs was taken into account. These ion pairs are supposed to evolve through dehydration to form the various calcium carbonate solid form precursors. This thermodynamic study was then compared to the experimental methods of the critical pH. Here the pH rise was caused by adding sodium hydroxide under different conditions for sodium hydroxide addition speed, agitation mode and ageing of solutions. For the highest speed of sodium hydroxide addition, the CaCO3 ionic product reached the value of the amorphous calcium carbonate solubility product, and the reaction of the amorphous calcium carbonate precipitation was of the homogenous type. Decreasing the reagent's addition speed caused an extension of the titration time. Then, the breakdown of the metastable state was obtained with the CaCO3 x H2O heterogeneous precipitation. This clearly illustrates the probable ageing of the precursors of the solid states that are considered in this model.
The use of microdialysis sampling coupled to oxygen sensors for monitoring oxygen tension in the tissue of animals was examined. The response time of the microdialysis sampling system was not different than oxygen sensors implanted directly in the tissue. The microdialysis system could be calibrated in vivo using the no-net-flux calibration method while directly implanted oxygen sensors had to rely on in vitro calibration. No difference was found in the oxygen tensions determined in vivo between microdialysis sampling and direct sensor implantations.
In human and veterinary medicine, arterial and venous haemoglobin oxygen saturations are often used to estimate the severity of a disease and to guide therapeutic decisions. In veterinary medicine, haemoglobin oxygen saturation (SO(2)) is usually calculated using a blood gas analyser and algorithms developed for humans. It is possible, therefore, that the values obtained in animals may be distorted, particularly in animals with a high haemoglobin oxygen affinity, like young calves. In order to verify this hypothesis, we compared the arterial (SaO(2)) and venous (SvO(2)) haemoglobin oxygen saturations calculated using three different algorithms, and the oxygen exchange fraction (OEF) at the tissue level, which is the degree of haemoglobin desaturation between arterial and venous blood (SaO(2)-SvO(2)), with the values obtained from the whole bovine oxygen equilibrium curve (OEC) determined by a reference method. The blood gas analysers underestimated SvO(2) values; consequently, the OEF was overestimated (by about 10%). Two methods of reducing these errors were assessed. As the haemoglobin oxygen affinity decreases during the first month of life in calves a relationship between PO(2) at 50% haemoglobin saturation (P50) and age was established in order to correct the calculated values of venous and arterial SO(2), taking into account the estimated position of the OEC. This method markedly reduced the error for SvO(2) and OEF. Secondly, the SO(2) was calculated using a mathematical model taking into account the age of the animal and the specific effects of pH, PCO(2), and temperature on the bovine OEC. Using this method, the mean difference between the OEF values calculated using the mathematical model and those calculated by the reference method was close to zero. The errors produced by blood gas analysers can thus be minimised in two ways: firstly, by simply introducing a P50 estimated from the age of the calf into the analyser before the measurement; and secondly, by calculating the SO(2) using a mathematical model applied to the bovine OEC.
Explore the source record for details and available documents.
Using gas exchange, enzyme assays, and theoretical modeling of photosynthetic responses to light and CO(2), we investigated whether decarbamylation of the active site of Rubisco at low CO(2) and low light leads to a condition where the activation state of Rubisco directly limits the rate of net CO(2) assimilation. Photosynthetic limitation by a reduction in the activation state of Rubisco would be indicated as a decline in the initial slope of the photosynthetic CO(2) response relative to what is predicted using theoretical models. In bean (Phaseolus vulgaris) and oat (Avena sativa), we saw no discrepancy between predicted and observed initial slope values at 200 and 400 mbar O(2), indicating no limitation by the carbamylation state of Rubisco. At 30 mbar O(2) and light saturation, we also saw no discrepancy between predicted and observed initial slope values; however, at subsaturating light intensity, our observed initial slope values were less than the modeled initial slope values that corresponded to an RuBP regeneration limitation. Moreover, significant reduction of the Rubisco activation state occurred in both species at 30 mbar O(2) and 30 mubar CO(2). When the model was reprogrammed to account for observed levels of Rubisco deactivation, the predicted and measured initial slope values at low O(2) and low PPFD were similar, indicating the reduction in carbamylation state accounted for the discrepancy. We interpret this as evidence for a direct limitation of the carbamylation state of Rubisco, probably because of a CO(2) limitation for carbamate formation. This limitation was only observed at intercellular CO(2) levels below what is encountered in vivo. At physiologically relevant CO(2) levels in situ, the leaves maintained sufficient Rubisco activity to avoid cabamylation state limitations in the steady state.