Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

A novel functional neuron group for respiratory rhythm generation in the ventral medulla.

We visualized respiratory neuron activity covering the entire ventral medulla using optical recordings in a newborn rat brainstem-spinal cord preparation stained with voltage-sensitive dye. We measured optical signals from several seconds before to several seconds after the inspiratory phase using the inspiratory motor nerve discharge as the trigger signal; we averaged the optical signals of 50-150 respiratory cycles to obtain an optical image correlating particularly to inspiratory activity. The optical images we obtained from the ventral approach indicated that neuron activity first appeared during the respiratory cycle in the limited region of the rostral ventrolateral medulla (RVLM), preceding the onset of inspiratory activity by approximately 500 msec. During the inspiratory phase, plateau activity appeared in the more caudal ventrolateral medulla at the level of the most rostral roots of the XIIth nerve. Comparison with electrophysiological recordings from respiratory neurons in the RVLM suggested that the optical signals preceding the inspiratory burst reflect preinspiratory neuron activity in this area. This RVLM area was determined to be ventrolateral to the facial nucleus and close to the ventral surface. We referred to this functional neuron group as the para-facial respiratory group (pFRG). Partial, bilateral electrical lesioning of the pFRG significantly reduced the respiratory frequency, together with changes in the spatiotemporal pattern of respiratory neuron activity. Our findings suggest that the pFRG comprises a neuronal population that is involved in the primary respiratory rhythm generation in the rostrocaudally extending respiratory neuron network of the medulla.

Animals↗

In vivo continuous-wave optical breast imaging enhanced with Indocyanine Green.

We investigate the uptake of a nontargeted contrast agent by breast tumors using a continuous wave diffuse optical tomography apparatus. The instrument operates in the near-infrared spectral window and employs 16 sources and 16 detectors to collect light in parallel on the surface of the tumor-bearing breast (coronal geometry). In our protocol an extrinsic contrast agent, Indocyanine Green (ICG), was injected by bolus. Three clinical scenarios with three different pathologies were investigated. A two-compartment model was used to analyze the pharmacokinetics of ICG and preprocess the data, and diffuse optical tomography was used for imaging. Localization and delineation of the tumor was achieved in good agreement with a priori information. Moreover, different dynamical features were observed for differing pathologies. The malignant cases exhibited slower rate constants (uptake and outflow) compared to healthy tissue. These results provide further evidence that in vivo pharmacokinetics of ICG in breast tumors may be a useful diagnostic tool for differentiation of benign and malignant pathologies.

Adenocarcinoma↗

Evaluation of the early response in fMRI in individual subjects using short stimulus duration.

Optical imaging studies have provided evidence of an initial increase in deoxyhemoglobin following the onset of neuronal stimulation/activation and demonstrated that this initial increase could be spatially more specific to the site of neuronal activity. These studies also raised the possibility of improving the specificity of fMRI by selective mapping of this early response. Previous MR studies reported the observation of this early response but were limited in scope and not in full agreement. This paper presents a more extensive study that (a) demonstrates the initial signal decrease in individual subjects and (b) examines its dependence on stimulus duration and subject. Binocular visual stimulation experiments were performed on 14 subjects using echo-planar imaging (EPI) with high temporal resolution. An initial signal decrease was consistently observed in regions that were more localized than those displaying the delayed positive response. In agreement with previous fMRI and optical imaging findings, the maximum signal decrease was 1-2% and occurred at approximately 2 s after the onset of the stimulus, depending on the subject. For stimulus longer then 3.0 s, the temporal dynamics and the amount of signal change of the early response was essentially independent of the stimulus duration, while the delayed response and the post-stimulus undershoot increased both in terms of magnitude and rise time as the duration of the stimulus increased; this observation is concordant with the recent optical imaging study.

Brain↗

Intrinsic optical signal imaging of neocortical seizures: the 'epileptic dip'.

Focal neocortical seizures, induced by injection of 4-aminopyridine, were imaged in the rat neocortex using the intrinsic optical signal, with incident light at various wavelengths. We observed focal, reproducible and prolonged reflectance drops following seizure onset, regardless of wavelength, in the ictal onset zone. A persistent drop in light reflectance with incident orange light, which corresponds to a decrease in oxygenated hemoglobin, was observed. We describe this phenomenon as an 'epileptic dip' as it is reminiscent of the 'initial dip' observed using the intrinsic optical signal, and also with blood oxygen level-dependent functional magnetic resonance imaging, after normal sensory processing, although with much longer duration. This persistent ictal ischemia was confirmed by direct measurement of tissue oxygenation using oxygen-sensitive electrodes.

4-Aminopyridine↗

MR imaging anatomy of the optic pathways.

Imaging in neuro-ophthalmology is a major, developing field. Visual and motor ocular symptoms and signs are of diagnostic and localizing significance, and occur frequently in patients with brain space-occupying lesions. Knowledge of the anatomy of the optic pathways extending from the retina to the calcarine fissure throughout the brain is crucial. Multiplanar high resolution MR imaging permits the physician to depict the visual path with exquisite detail. This article provides a correlative regional anatomic and imaging atlas of the brain following the optic pathways, with reference to the most accurate technical imaging procedures.

Anatomy, Artistic↗

Autofluorescence of skin burns detected by fiber-optic confocal imaging: evidence that cool water treatment limits progressive thermal damage in anesthetized hairless mice.

BACKGROUND: Although full-thickness burns present no difficulty to clinical judgment, accurate assessment of burn depth immediately after injury in partial thickness burns has always been difficult. METHODS: Thermal burns (applied by a 3-mm-diameter brass rod heated to 50 degrees--80 degrees C for 20 seconds) were induced on the skin of anesthetized hairless mice. Anesthesia was maintained throughout all experiments. Both burns and normal skin were investigated noninvasively in vivo using fiber-optic confocal imaging (FOCI) microscopy (excitation, 488 nm; detection, 505 nm). RESULTS: Autofluorescence was detected in burned skin, and the depth of the autofluorescent region was found to correlate with the intensity of heat applied. Cool water treatment (for 20 minutes immediately after burn induction) significantly reduced the progressive increase in autofluorescence in deeper layers of the skin over the 4-hour postburn observation period. Histology showed burn-associated changes at a lower temperature than that at which autofluorescence was first detected in vivo by FOCI. However, there was a good correlation (r = 0.78) between depth of damage revealed by FOCI compared with that by histology. CONCLUSION: These results suggest that FOCI may be used to provide an index of burn depth.

Animals↗

Imaging in diffuse media with pulsed-ultrasound-modulated light and the photorefractive effect.

Acousto-optic imaging in diffuse media is a dual wave-sensing technique in which an acoustic field interacts with multiply scattered laser light. The acoustic field causes a phase modulation in the optical field emanating from the interaction region, and this phase-modulated optical field carries with it information about the local optomechanical properties of the media. We report on the use of a pulsed ultrasound transducer to modulate the optical field and the use of a photorefractive-crystal-based interferometry system to detect ultrasound-modulated light. The use of short pulses of focused ultrasound allows for a one-dimensional acousto-optic image to be obtained along the transducer axis from a single, time-averaged acousto-optic signal. The axial and lateral resolutions of the system are controlled by the spatial pulse length and width of the ultrasound beam, respectively. In addition, scanning the ultrasound transducer in one dimension yields two-dimensional images of optical inhomogeneities buried in turbid media.

Diffusion↗

[Fluorescence spectroscopy and imaging for optical biopsy].

In the past few years extensive attention has turned toward optical biopsy, because of its ability to perform noninvasive, real time and accurate diagnosis of tissue pathologies, especially precancer. Fluorescence spectroscopy is one of a series of techniques widely developed for optical biopsy, and can be generally divided into two categories: fluorescence spectroscopy and imaging. This paper reviews the applications of autofluorescence and exogenous fluorescence to optical biopsy, and the principle and advantages as well as the clinic applications of various steady-state and time-resolved fluorescence spectroscopy and imaging techniques. Furthermore, the development perspectives of optical biopsy by using fluorescence spectroscopy and imaging are also briefly discussed.

Biopsy↗

Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry.

AIMS: The development of imaging and measurement techniques has brought the prospect of greater objectivity in the measurement of optic disc features, and therefore better agreement between observers. The purpose of this study was to quantify and compare the variation between observers using two measurement devices. METHODS: Optic disc photographs and images from the Heidelberg retina tomograph (HRT) of 30 eyes of 30 subjects were presented to six observers for analysis, and to one observer on five separate occasions. Agreement between observers was studied by comparing the analysis of each observer with the median result of the other five, and expressed as the mean difference and standard deviation of differences between the observer and the median. Inter- and intraobserver variation was calculated as a coefficient of variation (mean SD/mean x 100). RESULTS: For planimetry, agreement between observers was dependent on observer experience, for the HRT it was independent. Agreement between observers (SD of differences as a percentage of the median) for optic disc area was 4.0% to 7.2% (planimetry) and 3.3% to 6.0% (HRT), for neuroretinal rim area it was 10.8% to 21.0% (planimetry) and 5.2% to 9.6% (HRT). The mean interobserver coefficient of variation for optic disc area was 8.1% (planimetry) and 4.4% (HRT), for neuroretinal rim area it was 16.3% (planimetry) and 8.1% (HRT), and (HRT only) for rim volume was 16.3%, and reference height 9.1%. HRT variability was greater for the software version 1.11 reference plane than for version 1.10. The intraobserver coefficient of variation for optic disc area was 1.5% (planimetry) and 2.4% (HRT), for neuroretinal rim area it was 4.0% (planimetry) and 4.5% (HRT). CONCLUSIONS: Variation between observers is greatly reduced by the HRT when compared with planimetry. However, levels of variation, which may be clinically significant, remain for variables that depend on the subjective drawing of the disc margin.

Glaucoma↗

Simultaneous multi-site recordings of neural activity with an inline multi-electrode array and optical measurement in rat hippocampal slices.

Understanding neuronal network function requires multi-site recording. An optical imaging method using voltage-sensitive dyes (VSD) is one such suitable method. It is also important to complement this technique with methods that measure other physiological parameters of neuronal network activity. We aimed to develop a multi-channel electrode method that would easily permit the simultaneous optical imaging of neural activity in vitro. There are several multi-electrode systems; some of these are commercially available, but they are not easy to use and are also expensive. We developed a novel, less expensive, stainless steel inline electrode array that utilizes the standard etching method of circuit board manufacturing. This method, along with widely available computer drawing software, allowed us to produce electrode arrays with uniform quality in electrical characteristics and shapes. The electrode array was designed so that it could easily substitute for single electrode systems without modifying the conventional set-up used for electrophysiological measurements and optical recordings. Simultaneous measurement of evoked neural activities in area CA1 of the rat hippocampal slice with our optical imaging method using the VSD Di-4-ANEPPS is demonstrated in this paper. The electrode array was also used as a stimulating electrode, and the evoked response was measured by the optical recording method. The results demonstrate the advantages of simultaneous recordings obtained by these complementary multi-site recording methods in vitro.

Animals↗

Advances in optical coherence tomography imaging for dermatology.

Optical coherence tomography (OCT) is a non-invasive imaging technique, which has previously demonstrated potential for use in dermatology. The purpose of this study is to demonstrate how improvements in image quality, speed, and functionality enable qualitative and quantitative information to be obtained from in vivo human skin. We developed a portable fiber-optic based OCT imaging device that requires only 1 second to simultaneously provide high-resolution images of skin structure, collagen birefringence, and blood flow. Images of normal human skin were acquired in vivo, and features compared with clinical and histologic observations. The layered structure and appendages of skin were apparent in conventional OCT images, and correlated well with corresponding histology. Polarization-sensitive OCT images simultaneously revealed birefringent regions within the dermis corresponding to the location of collagen fibers, as confirmed with polarized light microscopy. Properties of collagen-rich tissues including tendon and scar tissues were quantified. Location of blood flow was also displayed alongside structural and polarization-sensitive images. Significant improvements in OCT technology have been made since its early application in dermatology. In particular, combining the previously described structural and Doppler imaging functions with polarization-sensitive imaging increases the utility of the technique for rapid, non-invasive investigations in the skin.

Cicatrix↗

Color processing in macaque striate cortex: relationships to ocular dominance, cytochrome oxidase, and orientation.

We located clusters of color-selective neurons in macaque striate cortex, as mapped with optical imaging and confirmed with electrophysiological recordings. By comparing responses to an equiluminant red/green stimulus versus a high-contrast luminance stimulus, we were able to reveal a patchy distribution of color selectivity. Other color imaging protocols, when compared with electrophysiological data, did not reliably indicate the location of functional structures. The imaged color patches were compared with other known functional subdivisions of striate cortex. There was a high degree of overlap of the color patches with the cytochrome-oxidase (CO) blobs. The patches were often larger than a single blob in size, however, and in some instances spanned two neighboring blobs. More than one-half (56%) of the color-selective patches seen in optical imaging were not confined to one ocular dominance (OD) column. Almost one-quarter of color patches (23%) extended across OD columns to encompass two blobs of different eye preference. We also compared optical images of orientation selectivity to maps of color selectivity. Results indicate that the layout of orientation and color selectivity are not directly related. Specifically, despite having similar scales and distributions, the maps of orientation and color selectivity were not in consistent alignment or registration. Further, we find that the maps of color selectivity and of orientation are each only loosely related to maps of OD. This description stands in contrast to a common depiction of color-selective regions as identical to CO blobs, appearing as pegs in the centers of OD columns in the classical "ice cube" model. These results concerning the pattern of color selectivity in V1 support the view (put forth in previous imaging studies of the organization of orientation and ocular dominance) that there is not a fundamental registration of functional hypercolumns in V1.

Animals↗

Multimodality in vivo molecular-genetic imaging.

Multimodality imaging is increasingly being used in molecular-genetic studies in small animals. The coupling of nuclear and optical reporter genes represents the beginning of a far wider application of this technology. Optical imaging and optical reporter systems are cost-effective and time-efficient, they require less resources and space than PET or MRI, and they are particularly well suited for small animal imaging and for in vitro assays to validate different reporter systems. However, optical imaging techniques are limited by depth of light penetration and scatter and do not yet provide optimal quantitative or tomographic information. These issues are not limiting for PET- or MRI-based reporter systems, and PET- and MRI-based animal studies are more easily generalized to human applications. Many of the shortcomings of each modality alone can be overcome by the use of dual- or triple-modality reporter constructs that incorporate the opportunity for PET, fluorescence and bioluminescence imaging. We optimistically expect that some form of tomographic, small animal optical imaging capability will be developed soon, and that this will provide the opportunity for the colocalization of optical signals to anatomical structures provided by tomographic CT and MR imaging.

Animals↗

Slit camera focal spot measurement errors in mammography.

Mammography x-ray tube focal spot sizes are routinely measured during acceptance testing and annual performance audits. The National Electrical Manufactures Association (NEMA) recommends the slit camera for this purpose. Investigated were the effect of slit rotational misalignment, tilt misalignment, image film density, film and screen-film image receptors, microscope magnification and reticule accuracy, and observer variation on slit camera focal spot measurements. Our results indicate that small rotational misalignment (< 5 degrees) and tilt misalignment (< 3 degrees) introduce insignificant error. Measured focal spot size increased slightly with image optical density, indicating that for consistent results the image optical density variations should be minimized. Also desirable for accurate field measurements is a high power microscope (25-50x) and a reticule with divisions of < or = 0.02 mm. Screen-film imaging consistently resulted in a slightly smaller measured focal spot size than direct film. The greatest source of error was due to observer variation. Of interest is that reader variability showed a consistent pattern and variation between two measurements by the same observer was much smaller than between observer variation, suggesting that standardized criteria should be established and a method of reader training developed. The length of the focal spot is defined at a reference axis angle specified by the mammography unit manufacturer. Presented is a tabulation of the focal spot geometry and reference axis angles for the majority of mammography units currently and recently marketed in North America.

Biophysical Phenomena↗

Near-field scanning optical microscopy imaging of multimode interference.

By use of a near-field scanning optical microscope (NSOM) in collection mode, the intensity distribution along a 2 x 2 multimode interference coupler was directly imaged as a function of wavelength. Although calculations can predict the general trend of wavelength dependence and the approximate positions of multiple images in the coupler, the accuracy is poor because of uncertainties in the waveguide width. We show that direct imaging using a NSOM bypasses calculational uncertainties and proves to be a powerful technique for studying these waveguide devices.

Journal Article↗

3D in-vivo optical skin imaging for topographical quantitative assessment of non-ablative laser technology.

BACKGROUND: A new method for treating facial rhytides and acne scars with nonablative laser and light source techniques has recently been introduced. Given the inherent limitations of photographic and clinical evaluation to assess subtle changes in rhytides and surface topography, a new noninvasive objective assessment is required to accurately assess the outcomes of these procedures. OBJECTIVE: The purpose of this study was to measure and objectively quantify facial skin using a novel, noninvasive, In-vivo method for assessing three-dimensional topography. This device was used to quantify the efficacy of five treatment sessions with the 1064 nm QS Nd:YAG laser for rhytides and acne scarring, for up to six months following laser treatment. METHODS: Two subjects undergoing facial rejuvenation procedures were analyzed before and after therapy using a 30-mm, three-dimensional microtopography imaging system (PRIMOS, GFM, Teltow, Germany). The imaging system projects light on to a specific surface of the skin using a Digital Micromirror Device (DMD Texas Instruments, Irving, TX) and records the image with a CCD camera. Skin Surface microtopography is reconstructed using temporal phase shift algorithms to generate three-dimensional images. Measurements were taken at baseline, at various times during the treatment protocol, and then at three and six-month follow-up visits. Silicone skin replicas (FLEXICO, Herts, England) were also made before and after the laser treatment protocol for comparison to In-vivo acquisition. RESULTS: Skin roughness decreased by 11% from baseline after three treatment sessions in the wrinkles subject, while a 26% improvement of skin roughness was recorded by 3D In-vivo assessment six months following the fifth treatment session. The subject with acne scarring demonstrated a 33% decrease in roughness analysis after three treatment sessions by 3D In-vivo assessment. A 61% improvement in surface topography was recorded 3-months following the fifth treatment session, which was maintained at the 6-month follow-up. CONCLUSION: Three-dimensional In-vivo optical skin imaging provided a rapid and quantitative assessment of surface topography and facial fine lines following multiple treatment sessions with a 1064-nm QS Nd:YAG laser, correlating with clinical and subjective responses. This imaging technique provided objective verification and technical understanding of nonablative laser technology. Wrinkle depth and skin roughness decreased at the three and six-month follow-up evaluations by 3D In-vivo assessment, indicating ongoing dermal collagen remodeling after the laser treatment protocol. Future applications may include comparison of nonablative laser technology, optimization of treatment regimens, and objective evaluation of other aesthetic procedures performed by dermatologists.

Acne Vulgaris↗

Improved accuracy of reconstructed diffuse optical tomographic images by means of spatial deconvolution: two-dimensional quantitative characterization.

Systematic characterization studies are presented, relating to a previously reported spatial deconvolution operation that seeks to compensate for the information-blurring property of first-order perturbation algorithms for diffuse optical tomography (DOT) image reconstruction. In simulation results that are presented, this deconvolution operation has been applied to two-dimensional DOT images reconstructed by solving a first-order perturbation equation. Under study was the effect on algorithm performance of control parameters in the measurement (number and spatial distribution of sources and detectors, presence of noise, and presence of systematic error), target (medium shape; and number, location, size, and contrast of inclusions), and computational (number of finite-element-method mesh nodes, length of filter-generating linear system, among others) parameter spaces associated with computation and the use of the deconvolution operators. Substantial improvements in reconstructed image quality, in terms of recovered inclusion location, size, and contrast, are found in all cases. A finding of practical importance is that the method is robust to appreciable differences between the optical coefficients of the media used for filter generation and those of the target media to which the filters are subsequently applied.

Algorithms↗

Imaging of optic nerve head drusen with the scanning laser ophthalmoscope.

BACKGROUND: Optic nerve head drusen may present diagnostic difficulties in cases of disc swelling. Imaging of the nerve in a search for drusen is often inconclusive, especially in children, where drusen may be buried below the surface of the nerve head. METHODS: A small study was carried out using a scanning laser ophthalmoscope (SLO) with an infrared confocal facility to scan deep within optic discs in an attempt to image drusen. RESULTS: The SLO was able to demonstrate superficial and buried drusen (using the infrared confocal facility). The superiority of the SLO over ultrasound in the presence of lens opacity was revealed, as the SLO simultaneously demonstrated both drusen and the associated anomalous disc features which are not detected by ultrasound. CONCLUSION: The SLO can help in the diagnosis of optic disc drusen especially in difficult cases where lens opacity or buried drusen hinders their definitive diagnosis.

Adolescent↗