Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Motion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Interocular motion combination for dichoptic moving stimuli.

When gratings moving in different directions are presented separately to the two eyes, we typically perceive periods of the combination of motion in the two eyes as well as periods of one or the other monocular motions. To investigate whether such interocular motion combination is determined by the intersection-of-constraints (IOC) or vector average mechanism, we recorded both optokinetic nystagmus eye movements (OKN) and perception during dichoptic presentation of moving gratings and random-dot patterns with various differences of interocular motion direction. For moving gratings, OKN alternately tracks not only the direction of the two monocular motions but also the direction of their combined motion. The OKN in the combined motion direction is highly correlated with the perceived direction of combined motion; its velocity complies with the IOC rule rather than the vector average of the dichoptic motion stimuli. For moving random-dot patterns, both OKN and perceived motion alternate only between the directions of the two monocular motions. These results suggest that interocular motion combination in dichoptic gratings is determined by the IOC and depends on their form.

Adult↗

When motion is not perceived: evidence from adaptation and dynamical stability.

Adaptation was used to probe the perceiver's activation state when either motion or nonmotion percepts are formed for bistable, single-element apparent motion stimuli. Although adaptation was not observed in every instance, when it was observed its effect was to increase the probability of both motion-to-nonmotion and nonmotion-to-motion switches, the time scale of adaptation corresponding to neurophysiological observations for directionally selective cortical cells (Giaschi et al. 1993). This susceptibility to de-stabilizing adaptation effects indicated that the nonmotion percept was not the result of inadequate stimulation producing subthreshold levels of motion detector activation; if that were the case, activation-dependent adaptation would have decreased the nonmotion-to-motion switching rate by reducing activation further below threshold. Above-threshold activation levels are therefore associated with both nonmotion and motion perceptual states, and the failure to perceive motion despite the presence of adequate motion detector stimulation can be attributed to inhibitory competition between detectors activated by motion-specifying stimulus information and detectors activated to similar levels by motion-independent stimulus information, consistent with the dynamical quality of single-element apparent motion.

Adaptation, Ocular↗

Atlantoaxial rotatory fixation: part 2--new diagnostic paradigm and a new classification based on motion analysis using computed tomographic imaging.

OBJECTIVE: This is Part II of a study on atlantoaxial rotatory fixation (AARF) that aims to introduce a new diagnostic paradigm and a new classification of this condition based on motion analysis of C1C2 rotation using computed tomographic (CT) imaging. This phase of the study is possible because Part I succeeded in defining physiological C1C2 axial rotation with CT data from 21 normal children, displayed in a highly concordant composite motion curve, which is used as the normal template for the present study. AARF is defined as flagrant departure from normal motion dynamics as delineated by abnormal motion curves. The new classification is predicated on the graded amount of pathological stickiness in the restricted rotation. METHODS: Forty children age 1.5 to 14 years with painful "cock-robin" necks resulting from minor trauma or otolaryngological procedures were subjected to 3 CT examinations: 1) in the presenting (P) position; 2) with the nose pointing up (P0 position); and 3) with the head forcefully turned to the opposite side as much as the patient could tolerate (P_ position). The angles made by C1 and C2 and the separation angle C1C2 degrees (C1 minus C2 degrees) were obtained as described in Part I. The test motion curve was generated by plotting C1 against C1C2 angles, and all motion curves were analyzed in the context of the normal template. RESULTS: Five distinct groups with highly characteristic motion curves could be identified. Group 1 (n = 5) patients showed essentially unaltered ("locked") C1C2 coupled configurations regardless of corrective counterrotation, with curves that are horizontal lines in the upper two quadrants of the template. Group 2 (n = 7) patients had reduction of the C1C2 separation angle with forced correction, but C1 could not be made to cross C2. Their curves slope downward from right to left in the upper quadrants but never traverse the x axis. Group 3 (n = 9) patients showed C1C2 crossover, but only when the head was cranked far to the opposite side. Their motion curves traverse the x axis left of C1 = -20 degrees. Groups 1, 2, and 3 motion dynamics are respectively classified as Types I, II, and III AARF in descending degree of pathological stickiness, which is in essence a resistance against closure of the C1C2 angle to counterrotation. Group 4 (n = 14) patients had normal dynamics, and Group 5 (n = 5) patients showed motion curve features between normal and Type III AARF, designated as belonging to the diagnostic gray zone, an uncertain group that may or may not revert to normal dynamics with only comfort measures. CONCLUSION: AARF can be reliably diagnosed with a simple and practical CT protocol and construction of a three-point motion curve superimposed on a reusable normal template. The type of AARF, reflective of the severity of pathological stickiness of rotation, can be identified readily by the shape of the motion curve. This system of classification is useful in selecting the best regimen of management.

Adolescent↗

Correspondence-based and energy-based detection of second-order motion in human vision.

Motion in the retinal image may occur either in the form of spatiotemporal variations in luminance (first-order motion) or as spatiotemporal variations in characteristics derived from luminance, such as contrast (second-order motion). Second-order motion patterns were employed in an attempt to establish the principles used for the detection of image motion in the human visual system. In principle, one can detect motion at a high level of visual analysis by identifying features of the image and tracking their positions (correspondence-based detection) or at a low level by analysis of spatiotemporal luminance variations without reference to features (intensity-based detection). Prevailing models favor the latter approach, which has been adapted to account for the visibility of second-order motion by postulation of a stage of rectification that precedes motion energy detection [J. Opt. Soc. Am. A 5, 1986 (1988)]. In two experiments it is shown that second-order motion is indeed detected normally by use of the strategy of transformation plus energy detection but that detection can also be achieved by use of the feature-correspondence strategy when the intensity strategy fails. In the first experiment, a stimulus is employed in which opposite directions of motion perception are predicted by the two strategies. It is shown that normally the direction associated with motion energy in the rectified image is seen but that the direction associated with feature motion is seen when the energy system is disabled by the use of an interstimulus interval.(ABSTRACT TRUNCATED AT 250 WORDS)

Contrast Sensitivity↗

Primary visual cortex activity along the apparent-motion trace reflects illusory perception.

The illusion of apparent motion can be induced when visual stimuli are successively presented at different locations. It has been shown in previous studies that motion-sensitive regions in extrastriate cortex are relevant for the processing of apparent motion, but it is unclear whether primary visual cortex (V1) is also involved in the representation of the illusory motion path. We investigated, in human subjects, apparent-motion-related activity in patches of V1 representing locations along the path of illusory stimulus motion using functional magnetic resonance imaging. Here we show that apparent motion caused a blood-oxygenation-level-dependent response along the V1 representations of the apparent-motion path, including regions that were not directly activated by the apparent-motion-inducing stimuli. This response was unaltered when participants had to perform an attention-demanding task that diverted their attention away from the stimulus. With a bistable motion quartet, we confirmed that the activity was related to the conscious perception of movement. Our data suggest that V1 is part of the network that represents the illusory path of apparent motion. The activation in V1 can be explained either by lateral interactions within V1 or by feedback mechanisms from higher visual areas, especially the motion-sensitive human MT/V5 complex.

Adult↗

The onset of receding motion captures attention: comment on Franconeri and Simons (2003).

Franconeri & Simons (2003) reported that some but not all types of motion capture attention in a visual search task, ostensibly because some types of motion are behaviorally significant. In the present article, we argue that a more parsimonious explanation of their results is that the onset of motion, but not motion per se, captures attention. This conclusion helps to resolve inconsistencies between the Franconeri and Simons findings and earlier reports from other investigators and is consistent with results that we have recently reported (Abrams & Christ, 2003). The Franconeri and Simons interpretation rests largely on their failure to find attentional capture by one type of motion-simulated receding motion. We report here the results of two experiments that demonstrate that the onset of receding motion does indeed capture attention when the motion is produced using stereo depth cues. As we have argued elsewhere, the capture of attention in displays containing motion appears to be dependent on the onset of the motion, rather than on the mere presence of specific types of motion as suggested by Franconeri and Simons. One possible explanation is that the onset of motion captures attention because it serves as a strong cue to animacy--and the detection of nearby animals can have important consequences for survival.

Attention↗

Motion structure in five-dot patterns as a determinant of perceptual grouping.

The effect of basic motion structures on perceptual grouping was studied with five-dot motion patterns. Four basic motion structures were identified in terms of proximal common and relative motion vectors. In a forced-choice situation, the observers had to decide to which of two pairs of dots a fifth critical dot seemed to belong. Thus, one of two possible three-dot units was chosen by the observers. The two possible three-dot units defined different motion structures, and the chosen motion structure was considered to have stronger grouping power than the alternative structure had. It was found that parallel common motions (perceived translation in the plane) had the strongest grouping power; these were followed by circular common motions (perceived rotation in the plane), concurrent relative motions (perceived translation in depth), and, finally, parallel relative motions (perceived rotation in depth). The results also suggested effects of proximity and orientation of axis of rotation. It is further argued that the relative grouping power of the motion structures could not solely be interpreted in terms of changes of directions and distances between the dots. Instead it is suggested that vector analysis is a fundamental perceptual activity and that basic motion structures determine grouping power.

Adult↗

Vestibular capture of the perceived distance of passive linear self motion.

The relative role of visual and vestibular cues in determining the perceived distance of passive, linear self motion were assessed. Seventeen subjects were given cues to constant acceleration motion: either optic flow, physical motion in the dark or combinations of visual and physical motion. Subjects indicated when they perceived they had traversed a distance that had been previously indicated either visually or physically. The perceived distance of motion evoked by optic flow was accurate relative to a visual target but was perceptually equivalent to a shorter physical motion. The perceived distance of physical motion in the dark was accurate relative to a previously presented physical motion but was perceptually equivalent to a much longer visually presented distance. The perceived distance of self-motion when both visual and physical cues were present was perceptually equivalent to the physical motion experienced and not the simultaneous visual motion even when the target was presented visually. We describe this dominance of the physical cues in determining the perceived distance of self motion as "vestibular capture".

Adult↗

Effect of seating, vision and direction of horizontal oscillation on motion sickness.

BACKGROUND: Low frequency horizontal oscillation can cause motion sickness in some forms of transport, but the influence of the characteristics of the motion and the visual and postural conditions of the body on sickness are not known. HYPOTHESES: It was hypothesised that body position, vision and direction of motion will have an effect on motion sickness. METHOD: There were 72 seated subjects who were exposed to horizontal oscillation at 0.25 Hz, 0.7 ms(-2) r.m.s. (peak-to-peak displacement of 0.8 m) for up to 30 min while in 1 of 6 conditions. Three conditions involved fore-and-aft motion and three involved lateral motion. For motion in each axis, subjects sat within a closed cabin with either: a) a high backrest with their eyes open; b) a low backrest with their eyes open; or c) a low backrest with their eyes closed and blindfolded. Subjects provided ratings of their motion sickness symptoms at 1-min intervals during the 30-min exposures. RESULTS: The most nauseogenic stimulus was fore-and-aft motion with a low backrest and the eyes open. Self-ratings of motion sickness susceptibility provided by subjects before participating in the experiment were positively correlated with their illness ratings during the experiment. CONCLUSIONS: Restraint to the upper body during exposure to horizontal acceleration may reduce the susceptibility to motion sickness caused by horizontal oscillation. The relative nauseogenicity of fore-and-aft and lateral oscillation depends on the support given to the upper body. In the conditions of the experiment the effects of the postural support given to the subjects and their prior susceptibility to motion sickness were greater than any effect of the visual conditions.

Acceleration↗

A psychophysical measurement and analysis of motion perception in normal and binocularly deprived monkeys.

PURPOSE: To measure psychophysically the thresholds for motion detection in the nasal and temporal directions under monocular viewing conditions in monkeys reared under conditions of daily alternating monocular occlusion (AMO). The hypothesis was that motion perception would be asymmetric with more sensitivity for motion in the nasal direction. METHODS: Three monkeys subjected to AMO (AMO monkeys) and three normal monkeys were studied. All were trained with operant conditioning techniques to discriminate coherent from random motion in a random dot display. The percentage of dots in the display that moved either left or right was varied. Thresholds for motion detection of nasally directed and temporally directed stimuli were measured to determine whether the motion perception of AMO monkeys was asymmetric, as predicted. RESULTS: A two-factor analysis of variance revealed a statistically significant difference between treatment groups (normal versus AMO) and directions (nasal versus temporal) and a significant interaction. The interaction was due to a significant difference between nasal and temporal directions for the AMO group, but no significant difference for the normal group. Planned comparisons were performed based on each animal's best eye (eye most sensitive to nasal motion) and worst eye (eye least sensitive to temporal motion). No significant differences were found between the two groups in the best eyes' responses to the nasal direction, but the worst eyes' responses in the temporal direction were significantly poorer in the AMO group. A neural model that can account for these findings is based on a Hebbian teacher located in the nucleus of the optic tract that strengthens connections of a subpopulation of directionally selective cortical neurons. CONCLUSIONS: AMO rearing results in asymmetric motion perception. Thresholds for detecting nasally directed motion are normal, whereas thresholds for detecting temporally directed motion are deficient. These results demonstrate that motion-processing mechanisms in primates exhibit experience-dependent developmental neural plasticity. The locus of the neural plasticity could be a subpopulation of directionally selective neurons in the striate cortex (V1).

Animals↗

The directions of nystagmus and apparent self-motion evoked by caloric tests and angular accelerations.

PURPOSE: To further investigate the direction of (I) nystagmus and (II) self-motion perception induced by two stimuli: (a) caloric vestibular stimulations and (b) a sudden halt during vertical axis rotation. SUBJECTS AND METHODS: Twelve normal humans received caloric stimulation at 44 degrees C, 30 degrees C, and 20 degrees C while in a supine position with the head inclined 30 degrees upwards. In a second test they were rotated around the vertical axis with the head randomly placed in two positions: tilted 30 degrees forward or tilted 60 degrees backward, at a constant velocity of 90 degrees /sec for 2 minutes and then suddenly stopped. After both tests they were asked to describe their sensations of self-motion. Eye movements were recorded with an infrared video-technique. RESULTS: Caloric stimulation evoked only horizontal nystagmus in all subjects and induced a non-uniform complex perception of angular in frontal and transverse planes (the former dominated) and linear movements along the antero-posterior axis (sinking dominated) of the subject's coordinates. The self-motion was felt with the whole body or with a part of the body. Generally the perception evoked by cold (30 degrees C) and warm (44 degrees C) calorics was similar, although there were some differences. The stronger stimulus (20 degrees C) evoked not only quantitative but also qualitative differences in perception. The abrupt halt of rotation induced self-motion perception and nystagmus only in the plane of rotation. The self-motion was felt with the whole body. CONCLUSION: There was no difference in the nystagmus evoked by caloric stimulation and a sudden halt of vertical axis rotation (in head positions to stimulate the horizontal canals); however, the two stimuli evoked different perceptions of self-motion. Calorics provoked the sensation of self-rotation in the frontal plane and linear motion, which did not correspond to the direction of nystagmus, as well as arcing and a reset phenomenon during angular and linear self-motion, caloric-induced self-motion can be felt predominantly or only with a part of the body, depending on the self-motion intensity. The findings indicate that, unlike the self-motion induced by sudden halt of vertical axis rotation, several mechanisms take part in generating caloric-induced self-motion.

Acceleration↗

Enhanced neural responses correlated with perceptual binding of color and motion.

When both color and motion direction of visual stimuli are alternated in physical synchrony at a relatively higher frequency (approximately 2 Hz), the changes in motion direction are perceived to be delayed. On the other hand, color and motion direction changes are perceived to be in phase when the motion direction changes precede the color changes by about 100 ms [Moutoussis, 1997]. In the present study, we utilized this phenomenon to investigate the neural mechanisms underlying the binding of color and motion based on the temporal synchrony. Magnetoencephalogram (MEG) was recorded for ten human subjects under the following four conditions: color change (color), motion direction change (motion), and simultaneous color and motion direction changes (color+motion) in perceptual synchrony (physical asynchrony) or in perceptual asynchrony (physical synchrony). The wavelet analysis was applied on these MEGs to study the neural responses in time-frequency domain. The interactions of color and motion responses, defined by [color+motion]-([color]+[motion]), were calculated in time-frequency domain for both perceptually synchronous and asynchronous conditions. The results showed significantly larger interactions at gamma band (30-35 Hz) under the condition of perceptual synchrony than under the condition of perceptual asynchrony, suggesting that synchronized neural responses at gamma band are related to the synchrony-based binding of visual attributes. This result is consistent with previous studies reporting the correlation of gamma band responses with perceptual grouping [Castelo-Branco, 2000] [Tallon-Baudry, 1996].

Color Perception↗

The chondrogenic potential of free autogenous periosteal grafts for biological resurfacing of major full-thickness defects in joint surfaces under the influence of continuous passive motion. An experimental investigation in the rabbit.

A rectangular graft of autogenous tibial periosteum was sutured (with its cambium layer facing into the joint) onto the base of a five by ten-millimeter full-thickness defect in the patellar groove of each of 143 adolescent and adult rabbits. The rabbits were managed postoperatively by either immobilization, intermittent active motion, continuous passive motion for two weeks, or continuous passive motion for four weeks. When the animals were killed four weeks postoperatively, the contour of the patellar groove had been restored in all of the rabbits in the group that had had four weeks of continuous passive motion, and the newly formed tissue in all of the defects in this group had the gross, histological, and histochemical appearance of smooth, intact hyaline articular cartilage. Histologically, the nature of the tissue that had formed, as well as its surface regularity, structural integrity, and bonding to the adjacent cartilage, were significantly better in the group that had had four weeks of continuous passive motion than in any of the other groups. The results were significantly worse when the orientation of the periosteal graft was reversed (that is, when it had been sutured into the defect with the cambium layer of the graft facing the subchondral bone rather than into the joint) or when no periosteal graft was used. Biochemical analyses revealed that, in the group that had had four weeks of continuous passive motion, the total hexosamine content, the levels of chondroitin sulphate and keratan sulphate, and the ratio of galactosamine to glucosamine were all comparable with the values for normal articular cartilage. In contrast, in the groups that were treated by immobilization, intermittent active motion, or two weeks of continuous passive motion, as well as in the adult rabbits, the content of the first three of these substances was significantly less than normal. In the groups that were treated by immobilization, intermittent active motion, or two weeks of continuous passive motion, 32 to 47 per cent of the total collagen was type II, while in the group that had had four weeks of continuous passive motion, 93 per cent of the total collagen was type II. These results demonstrate that, under the influence of continuous passive motion, free autogenous periosteal grafts can repair a large full-thickness defect in a joint surface by producing tissue that resembles articular cartilage grossly, histologically, and biochemically, and that contains predominantly type-II collagen.

Animals↗

The effect of autogenic training and biofeedback on motion sickness tolerance.

BACKGROUND: Motion sickness is characterized by symptoms of vomiting, drowsiness, fatigue and idiosyncratic changes in autonomic nervous system (ANS) responses such as heart rate (HR) and skin temperature (ST). Previous studies found that symptoms of motion sickness are controllable through self-regulation of ANS responses and the best method to teach such control is autogenic-feedback (biofeedback) training. Recent experiments indicated that biofeedback training is ineffective in reducing symptoms of motion sickness or in increasing tolerance to motion. HYPOTHESIS: If biofeedback facilitates learning of ANS self-regulation then autogenic training with true feedback (TFB) should lead to better control over ANS responses and better motion tolerance than autogenic training with false feedback (FFB). If there is a relationship between ANS self-regulation and coping with motion stress, a significant correlation should be found between amounts of control over ANS responses and measures of motion tolerance and/or symptoms of motion sickness. METHOD: There were 3 groups of 6 subjects exposed for 6 weeks to weekly sessions of Coriolis stimulation to induce motion sickness. Between the first and second Coriolis sessions, subjects in the experimental groups received five episodes of autogenic training with either true (group TFB) or false (group FFB) feedback on their HR and ST. The control group (CTL) received no treatment. RESULTS: Subjects learned to control their HR and ST independent of whether they received true or false feedback. Learned control of ST and HR was not related to severity of motion sickness or subject's ability to withstand Coriolis stimulation following treatment. CONCLUSIONS: A lack of significant correlation between these variables suggested that subjects were not able to apply their skills of ANS self-regulation in the motion environment, and/ or such skills had little value in reducing symptoms of motion sickness or enhancing their ability to withstand rotations.

Adolescent↗

Atomic resolution structure of prokaryotic phospholipase A2: analysis of internal motion and implication for a catalytic mechanism.

We have found a secreted phospholipase A(2) (PLA(2), EC 3.1.1.4) from Streptomyces violaceoruber A-2688, which is the first PLA(2) identified in prokaryote, and determined its tertiary structure by NMR and X-ray analyses. In this study, we collected the X-ray diffraction data of the bacterial PLA(2) at room temperature (297 K) using conventional MoK(alpha) radiation and refined the structure at a 1.05 A resolution. The atomic resolution analysis led us to introduce disordered conformations and hydrogen atoms into a full anisotropic model. The molecular motion, which is expressed as the sum of rigid-body motion and internal motion of protein, is roughly estimated as the thermal motion when the X-ray diffraction data are collected at room temperature. In this study, we applied a TLS (rigid-body motion in terms of translation, libration, and screw motions) model to analyze the rigid-body motion of the bacterial PLA(2) and calculated the internal motion by subtracting the estimate of the rigid-body motion from the observed anisotropic temperature factor. We also subjected the TLS model to estimate the internal motion of the bovine pancreatic PLA(2) using the anisotropic temperature factor deposited in the Protein Data Bank. Both results indicate that the localization of regions exhibiting larger internal motion in the bacterial PLA(2) is almost the same as that in the bovine pancreatic PLA(2), suggesting that although the tertiary structure of the bacterial PLA(2) is strikingly different from that of the bovine pancreatic PLA(2), the internal motion, which is associated with the calcium(II) ion-binding, phospholipid-binding, and allosteric interfacial activation, is commonly observed in both PLA(2)s.

Anisotropy↗

Crystallographic evaluation of internal motion of human alpha-lactalbumin refined by full-matrix least-squares method.

The low temperature form of human alpha-lactalbumin (HAL) was crystallized from a 2H2O solution and its structure was refined to the R value of 0.119 at 1.15 A resolution by the full-matrix least-squares method. Average estimated standard deviations of atomic parameters for non-hydrogen atoms were 0.038 A for coordinates and 0.044 A2 for anisotropic temperature factors (Uij). The magnitude of equivalent isotropic temperature factors (Ueqv) was highly correlated with the distance from the molecular centroid and fitted to a quadratic equation as a function of atomic coordinates. The atomic thermal motion was rather isotropic in the core region and the anisotropy increased towards the molecular surface. The statistical analysis revealed the out-of-plane motion of main-chain oxygen atoms, indicating that peptide groups are in rotational vibration around a Calpha.Calpha axis. The TLS model, which describes the rigid-body motion in terms of translation, libration, and screw motions, was adopted for the evaluation of the molecular motion and the TLS parameters were determined by the least-squares fit to Uij. The reproduced Ueqvcal from the TLS parameters was in fair agreement with observed Ueqv, but differences were found in regions of residues, 5-22, 44-48, 70-75, and 121-123, where Ueqv was larger than Ueqvcal because of large local motions. To evaluate the internal motion of HAL, the contribution of the rigid-body motion was determined to be 42.4 % of Ueqv in magnitude, which was the highest estimation to satisfy the condition that the Uijint tensors of the internal motion have positive eigen values. The internal motion represented with atomic thermal ellipsoids clearly showed local motions different from those observed in chicken-type lysozymes which have a backbone structure very similar to HAL. The result indicates that the internal motion is closely related to biological function of proteins.

Calcium↗

Folding funnels and conformational transitions via hinge-bending motions.

In this article we focus on presenting a broad range of examples illustrating low-energy transitions via hinge-bending motions. The examples are divided according to the type of hinge-bending involved; namely, motions involving fragments of the protein chains, hinge-bending motions involving protein domains, and hinge-bending motions between the covalently unconnected subunits. We further make a distinction between allosterically and nonallosterically regulated proteins. These transitions are discussed within the general framework of folding and binding funnels. We propose that the conformers manifesting such swiveling motions are not the outcome of "induced fit" binding mechanism; instead, molecules exist in an ensemble of conformations that are in equilibrium in solution. These ensembles, which populate the bottoms of the funnels, a priori contain both the "open" and the "closed" conformational isomers. Furthermore, we argue that there are no fundamental differences among the physical principles behind the folding and binding funnels. Hence, there is no basic difference between funnels depicting ensembles of conformers of single molecules with fragment, or domain motions, as compared to subunits in multimeric quaternary structures, also showing such conformational transitions. The difference relates only to the size and complexity of the system. The larger the system, the more complex its corresponding fused funnel(s). In particular, funnels associated with allosterically regulated proteins are expected to be more complicated, because allostery is frequently involved with movements between subunits, and consequently is often observed in multichain and multimolecular complexes. This review centers on the critical role played by flexibility and conformational fluctuations in enzyme activity. Internal motions that extend over different time scales and with different amplitudes are known to be essential for the catalytic cycle. The conformational change observed in enzyme-substrate complexes as compared to the unbound enzyme state, and in particular the hinge-bending motions observed in enzymes with two domains, have a substantial effect on the enzymatic catalytic activity. The examples we review span the lipolytic enzymes that are particularly interesting, owing to their activation at the water-oil interface; an allosterically controlled dehydrogenase (lactate dehydrogenase); a DNA methyltransferase, with a covalently-bound intermediate; large-scale flexible loop motions in a glycolytic enzyme (TIM); domain motion in PGK, an enzyme which is essential in most cells, both for ATP generation in aerobes and for fermentation in anaerobes; adenylate kinase, showing large conformational changes, owing to their need to shield their catalytic centers from water; a calcium-binding protein (calmodulin), involved in a wide range of cellular calcium-dependent signaling; diphtheria toxin, whose large domain motion has been shown to yield "domain swapping;" the hexameric glutamate dehydrogenase, which has been studied both in a thermophile and in a mesophile; an allosteric enzyme, showing subunit motion between the R and the T states (aspartate transcarbamoylase), and the historically well-studied lac repressor. Nonallosteric subunit transitions are also addressed, with some examples (aspartate receptor and BamHI endonuclease). Hence, using this enzyme-catalysis-centered discussion, we address energy funnel landscapes of large-scale conformational transitions, rather than the faster, quasi-harmonic, thermal fluctuations.

Adenylate Kinase↗

Postoperative abnormalities of interventricular septal motion: two-dimensional and M-mode echocardiographic correlations.

Our hypothesis was that the postoperative abnormalities in septal motion observed by M-mode echocardiography (MME) are due to changes of either ventricular shape or of total cardiac motion within the thorax. We obtained preoperative and early and late postoperative MME and two-dimensional echocardiograms on 25 patients undergoing cardiac surgery. No patient had coronary artery disease. All patients had normal preoperative septal motion; 11 patients retained normal (group N) septal motion on postoperative MME; 14 patients developed abnormal (group A) septal motion. Comparison of these two groups revealed that the group A patients had a greater degree of posterior epicardial motion toward the chest wall during systole. This indicates a greater anterior motion of the entire heart within the thorax, which produces the observed septal motion abnormality by carrying the septum forward passively as the whole heart moves anteriorly. This excessive forward cardiac motion may be due to fixation of the heart anteriorly by postoperative sternal-cardiac adhesions. No changes in left ventricular shape, size, or function were found to be associated with abnormal septal motion, nor was septal contraction impaired. Changes in intrathoracic cardiac motion are the probable cause of septal motion abnormalities after cardiac surgery.

Aortic Valve↗