Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Modifier”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Modified essay question.

This article examines the reliability and validity of the modified essay question. An 18-item modified essay question was developed and pretested on a group of clinical experts. After the pretest, the modified essay question was administered to a group of 25 physical therapy students immediately before their second level orthopedic placement. A reliability index of .39 (coefficient alpha) was calculated for the test. In addition, measures of validity were obtained by correlating the modified essay question scores with multiple-choice question scores and the students' in-clinic reasoning scores. The results suggest that the reliability coefficient found in this study is comparable to the medical literature. Also, the results showed that the modified essay question demonstrated a greater correlation with the in-clinic clinical reasoning score compared with the parallel content multiple-choice examination. Furthermore, preliminary evidence suggests that the modified essay question may be a useful paper and pencil tool in evaluating clinical reasoning. Finally, several shortcomings of this study are discussed in conjunction with a direction for further study.

Adult↗

Modified Blalock-Taussig shunt patency for pulmonary atresia: assessment with electron beam CT.

PURPOSE: The purpose of this work was to evaluate electron beam CT (EBCT) for the noninvasive assessment of modified Blalock-Taussig (BT) shunt patency in patients with pulmonary atresia. METHOD: Five infants and children with pulmonary atresia and modified BT shunts underwent contrast-enhanced EBCT. Modified BT shunts from the subclavian artery to the pulmonary artery were performed to improve the pulmonary blood flow. Electrocardiogram (ECG)-triggered EBCT was obtained with a 100 ms exposure, 3 mm section thickness, and 2 mm table feed after intravenous administration of contrast material. Three-dimensional (3D) or maximum intensity projection (MIP) EBCT images were compared with conventional angiography. The visibility of modified BT shunts was graded and recorded with use of a four-point scale. RESULTS: Satisfactory visualization was achieved in both 3D and MIP EBCT images to evaluate modified BT shunt patency. CONCLUSION: Contrast-enhanced 3D or MIP EBCT imaging with ECG trigger may be used as an effective substitute to evaluate modified BT shunts with low radiation dose exposure.

Blood Vessel Prosthesis Implantation↗

Bone interface of dental implants cytologically influenced by a modified sandblasted surface: a preliminary in vitro study.

To study the influences of a modified sandblasted surface (developed by the authors) on the integrating status of titanium (Ti) dental implants and bone in vitro, a three-dimensional experimental model of implant material-osteoblast culture was used. The interaction of Ti discs and osteoblasts at the interface was followed with phase-contrast microscope examination and was further observed histologically and ultra-structurally after one-month culture. Results showed that there was no significant difference between the modified sandblasted surface group and the smooth surface group in the capacity of osteoblasts migrating and attaching to Ti discs. There was, however, a significant difference in the pattern of attachment. Around the polished surface, the migrating and attaching osteoblasts oriented themselves parallel to it; however, around the modified sandblasted surface, the osteoblasts were migrating and attaching perpendicularly. There was also a major difference in the shapes of cells lining the interface; spindle-shaped on the smooth surface versus round and ovoid with a large cellular body and abundant cytoplasm on the modified sandblasted surface. Moreover, transmission electron microscopy revealed an active secretion of collagen fibrils, a bone-matrix-vesicles-mediated mineralization process, and the formation of osteocytes in the modified sandblasted surface group. Therefore, at this in vitro level, it can be concluded that the modified sandblasting surface treatment of dental implants can facilitate bone healing at their osseous interface and enable the real perpendicularly connecting bone-fiber osseointegration to form instead of the capsule-like osseous adaptation.

Cell Adhesion↗

Predictors and modifiers of treatment effect influencing sick leave in subacute low back pain patients.

STUDY DESIGN: Modifying effects in multivariate analyses of a randomized controlled trial. OBJECTIVES: To identify prognostic factors for the effect of a brief intervention ("modifiers") at a spine clinic on return to work in patients with subacute low back pain. SUMMARY OF BACKGROUND DATA: A previous study of a brief intervention showed significant reduction of sick leave, compared with usual primary healthcare treatment. Randomized controlled trials give data only on the group as an average. Identifying prognostic factors that interact with the treatment ("modifiers") may identify specific groups requiring this or other types of treatment. METHODS: A total of 457 patients who had been sick-listed 8 to 12 weeks for low back pain were randomized into an intervention group (spine clinic with medical examination, information, reassurance, encouragement to engage in physical activity, n = 237), and a control group (primary health care, n = 220). All subjects filled out questionnaires. Logistic regression and tests for interaction were used to identify prognostic factors and modifiers for return to work in the two groups, at 3 and 12 months of follow-up. RESULTS: At 3 months of follow-up, the strongest modifying effect on return to work was the perception of constant back strain when working and beliefs about reduced ability to work. At 12 months, gastrointestinal complaints were the strongest modifier for the effect of the intervention. CONCLUSION: The spine clinic intervention seems to have a main effect on work absenteeism via interacting with the concerns of being unable to work.

Adolescent↗

Antitumor effects of interleukin-2 gene-modified fibroblasts in an orthotopic colon cancer model.

We transduced the interleukin-2 (IL-2) gene into murine fibroblasts BALBCL7 or murine colon cancer CT26 using a retroviral vector. BALBCL7 transduced with IL-2 gene secreted 748 pg/ml of IL-2, whereas IL-2 gene-modified CT26 secreted 1,167 pg/ml of IL-2 (48 h incubation, 1x10(6)/ml). Then, we inoculated gene-modified BALBCL7 and/or CT26 cells into BALB/c female mice, and observed the tumor growth. The tumor growth was inhibited in mice inoculated with parental CT26 plus IL-2 gene-modified BALBCL7, compared with that in mice given parental CT26 alone (P<0.01). Moreover, we investigated the cytotoxic activity of spleen cells derived from mice treated with gene-modified cells, and performed phenotypic analysis of the effector cells. The killer cells derived from mice inoculated with IL-2 gene-modified BALBCL7 plus parental CT26 showed higher cytotoxic activity than those from mice inoculated with CT26 alone. The cytotoxic activity was almost completely blocked by anti-CD8 antibody (Ab), and partially blocked by anti-asialo GM1 Ab. Next, we inoculated CT26 tumor tissue into murine cecum orthotopically, and treated the animals with gene-modified BALBCL7 plus parental CT26. The tumor size in the cecum was significantly decreased, compared with parental CT26 alone (P<0.01).

Animals↗

Modified symbolic play test for Oriental children.

BACKGROUND: Symbolic play test (SPT) is a simple test for screening preverbal language in children. This test had been validated in English-speaking children. However, the toys may not be useful for other cultures such as Orientals like Chinese, Japanese, Koreans or Thais as they use chopsticks and bowls as eating utensils rather than spoon, fork or knife. The aim of this study was to find a set of miniature toys suitable for children of Oriental ethnic origin in order to get a reliable language test. METHODS: Altogether 140 children were recruited into this study. This included 62 control children and 78 with idiopathic developmental delay. The original SPT was applied together with an additional set of miniature toys appropriate for Oriental culture (i.e. modified version of SPT) by modifying play items in situations 3 and 4 to suit the Chinese culture. The authors replaced the knife, fork and plate with chopsticks and bowl in situation 3 and replaced the tractor and trailer with train carts in situation 4. For the ease of comparison, the authors segregated the age groups with the same age range as the original English-based SPT: less than 20 months (N= 11); 21-30 months (N= 45); 31-40 months (N= 43); 41-50 months (N= 21), and more than 50 months (N= 4). RESULTS: The mean scores of the cohort was higher (14.83) with the modified version of SPT than when the original SPT was used (13.64). A statistically significant increase in the mean score in situation 3 (3.67-3.24 = 0.43), situation 4 (3.76-3.36 = 0.40) and the overall score (14.83-13.64 = 1.19) was obtained when the modified SPT was used instead of the original SPT (all with P < 0.001). CONCLUSION: The authors recommend replacing play items like spoon, knife, fork and plate with Oriental culture-based items like chopsticks and bowl for the modified SPT (Oriental version). Users of the test should have a set of toy train carts available to supplement the tractor and trailer as these toys were not commonly seen in real life for Oriental children. The authors hope that the modified SPT can be used reliably to assess for preverbal ability of Oriental children, especially Chinese children.

Asian People↗

Modified Joel-Cohen technique for caesarean delivery.

OBJECTIVE: To investigate whether a series of changes in the current caesarean section operative routine, based on new knowledge, would be beneficial. DESIGN: A prospective controlled trial. SETTING: Labour ward with approximately 3000 deliveries annually in a suburban area of Gothenburg, Sweden. PARTICIPANTS: Seventy-two pregnant women scheduled for delivery by caesarean section were randomised to either modified Joel-Cohen technique (n = 36) or Pfannenstiel technique (n = 36). MAIN OUTCOME MEASURES: Blood loss during surgery and operating time. RESULTS: The median estimated intra-operative blood loss was 250 mL in the modified Joel-Cohen group and 400 mL in the Pfannenstiel group (P = 0.026). The proportion of women with > or = 300 mL was 16/36 in the modified Joel-Cohen group vs 28/36 in the Pfannenstiel group (OR 0.229, 95% CI 0.082-0.637). Median operating time was 20 min in the modified Joel-Cohen group compared with 28 min in the Pfannenstiel group (P < 0.001). The proportion of women with > or = 25 min was 1/36 in the modified Joel-Cohen group vs 33/36 in the Pfannenstiel group (OR 0.003, 95% CI 0.000-0.026). CONCLUSIONS: We conclude that the modified Joel-Cohen technique of caesarean delivery reduced intraoperative blood loss and operating time compared with the Pfannenstiel technique.

Adult↗

Improved retention of endothelial cells seeded on polyurethane small-diameter vascular grafts modified by a recombinant RGD-containing protein.

Sponge-type small-diameter vascular grafts were fabricated from a medical-grade polyurethane, Pellethane 2363-80A, by utilization of a salt casting technique. The grafts were compliance matched with a storage modulus of 0.53 +/- 0.08 MPa. The luminal surface of grafts was modified with a thin layer ( approximately 40 micro m) of gelatin crosslinked by epoxide. Then a special Arg-Gly-Asp (RGD)-containing recombinant protein, named CBD-RGD (cellulose binding domain RGD-containing protein), was coated onto the gelatin layer. The platelet adhesion and activation on such a gelatin/CBD-RGD modified surface was significantly reduced. Human umbilical vein endothelial cells were seeded more efficiently onto the modified grafts. There was also a substantial reduction in the subsequent loss of cells from the graft surface following perfusion in vitro. The cell number retained on the modified graft was enhanced by three times after 1 h of perfusion, and by eight times after 3 h of perfusion (retention rate approximately 63%). The retention after 3 h of perfusion could be further increased to nearly 100% if the lined endothelium on gelatin/CBD-RGD modified graft was cultured for another week before perfusion. The modified surface was also shown to help canine external jugular vein endothelial cells to maintain the round cell morphology in vitro.

Animals↗

Evaluation of biodegradable polyesters modified by type II collagen and Arg-Gly-Asp as tissue engineering scaffolding materials for cartilage regeneration.

Synthetic biodegradable polyesters poly(L-lactide) (PLLA) and poly(D,L-lactide-coglycolide) (PLGA) (50:50) modified by porcine type II collagen and an Arg-Gly-Asp (RGD)-containing protein were evaluated as scaffolds for cartilage regeneration in this study. Cytocompatibility of the polymer films was tested using immortalized chondrocytes. Neocartilage formation in vitro on cell-seeded scaffolds was further examined using primary porcine chondrocytes. The inflammatory response of the scaffolds was evaluated subcutaneously in rats. A pilot animal study was conducted, in which rabbit allogeneic chondrocyte-seeded scaffolds were implanted to repair the defected rabbit knee cartilage. The results demonstrated that PLGA as well as its blends with PLLA had better cell growth than pure PLLA, and that type II collagen enhanced, but RGD inhibited cell proliferation. Scaffolds made of blended PLLA/PLGA had larger dynamic compressive modulus compared to scaffolds made of PLLA or PLGA single polymer. Chondrocyte-seeded scaffolds modified by type II collagen without RGD had the greater number of cells as well as higher glycosaminoglycan (GAG) and collagen contents compared to scaffolds without type II collagen modification or scaffolds further modified with RDG. Type II collagen modification prevented infiltration by host tissue and capsule formation. Unmodified PLLA and PLLA/PLGA constructs demonstrated persisting inflammatory response after 6 months, while all type II collagen-modified PLLA/PLGA constructs showed complete repair and no inflammation. Partial or full repair was observed after 2 months of postimplantation in type II collagen-modified PLLA/PLGA constructs, with equal cellularity and 75-80% matrix contents of a normal rabbit articular cartilage. It was concluded that PLLA/PLGA blended scaffolds modified by type II collagen were a potential tissue engineering scaffold for cartilage regeneration.

Analysis of Variance↗

The generation of cytotoxic T lymphocytes against acetaldehyde-modified syngeneic cells.

The major metabolic product of ethanol is acetaldehyde. It is highly reactive with proteins. In situ this modification is significant enough to generate an antibody response. Whether an effector cellular immune response can be generated against these acetaldehyde modified adducts on syngeneic cells is not known. In this paper we have demonstrated in the murine system that acetaldehyde modified splenic cells can generate cytotoxic T lymphocytes (CTL). These CTL are specific for the acetaldehyde modified syngeneic cells, and not acetaldehyde modified allogeneic cells. The ability of the CTL to lyse-specific targets is dependent on the formation of stable acetaldehyde adducts. Cold target inhibition studies reveal that modified syngeneic cells can inhibit lysis as effectively as unmodified cells. Therefore, the present study lends support to the hypothesis that acetaldehyde modified cells can generate a cellular immune response and may do so in pathologic states.

Acetaldehyde↗

Relationship between alcohol intake and immunoglobulin a immunoreactivity with acetaldehyde-modified bovine serum albumin.

Acetaldehyde, the main metabolite of ethanol, is a highly reactive species that reacts with macromolecules to produce unstable and stable adducts. Acetaldehyde-modified proteins are immunogenic and have been detected in the liver and blood of alcoholics. Furthermore, antibodies reactive with acetaldehyde-modified proteins have been detected in the plasma of social drinkers and alcoholics. However, the class distribution of immunoglobulins reactive with modified proteins was different in the two groups, being predominantly immunoglobulin (Ig)M in social drinkers, but IgM and IgA in alcoholics. In this study, we demonstrate that heavy drinkers (alcohol intake > 130 g/week for females and 150 g/week for males) also exhibit IgA reactivity with acetaldehyde-modified proteins. The IgA adduct-specific reactivity (IgA reactivity with acetaldehyde-modified bovine serum albumin-reactivity with native bovine serum albumin) showed a moderate correlation with self-reported alcohol intake, but did not correlate with markers such as plasma transaminase, gamma-glutamyltransferase activity, or mean corpuscular volume. IgA adduct-specific reactivity had similar specificity to the conventional tests of alcohol abuse, but had higher sensitivity than the other tests, especially with heavy drinkers. Data presented herein demonstrate that elevated IgA reactivity with acetaldehyde-modified epitopes is associated with heavy drinking and is a potential marker for high alcohol intake.

Acetaldehyde↗

Modified TEI index: a promising parameter in essential hypertension?

PURPOSE: Modified TEI index is pointed to be more effective in the evaluation of global cardiac functions compared to systolic and diastolic measurements alone. We planned to determine its applicability in hypertension and relation with left ventricular mass index (LVMI). METHODS: We studied 48 patients with mild/moderate hypertension and normal coronary angiograms. In total 22 patients (12 men, 10 women, mean age: 55 +/- 6) with normal LVMI were studied in group I, 26 patients (12 men, 14 women, mean age: 57 +/- 7) with increased LVMI in group II, and 20 patients (10 men, 10 women, mean age: 53 +/- 7) with normal blood pressure as a control group. Standard 2D, Doppler, and mitral annulus pulse wave tissue Doppler were used for all measurements. Modified TEI index was calculated as diastolic time interval measured from end of Am wave to origin of Em (a') minus systolic Sm duration (b') divided by b(a'-b'/b'). RESULTS: Modified TEI index was significantly higher in both groups than normal group and in group II than in group I. ( CONTROL GROUP: 0.33 +/- 0.05, group I: 0.51 +/- 0.17, group II: 0.68 +/- 0.16, P< 0.0001). CONCLUSION: Modified TEI index, a marker of left ventricular systolic and diastolic functions, is impaired in hypertensives before hypertrophy develops and impairment is more prominent in hypertrophy. Therefore, (1) modified TEI index in hypertensives is a safe, feasible, and sensitive index for evaluation of global ventricular functions. (2) Evaluation of hypertensives with this index periodically may guide interventions directed toward saving systolic and diastolic functions. (3) Modified TEI index is gaining importance as a complementary parameter to standard Doppler or in cases where standard Doppler has its limitations.

Adult↗

Effect of chromium picolinate on modified forced swimming test in diabetic rats: involvement of serotonergic pathways and potassium channels.

Depression occurs frequently in patients with diabetes mellitus. Chromium picolinate, an essential trace element is recommended for diabetes and also has been reported to benefit depression, but its mechanism is still debated. To investigate the mechanism, we studied its effects on serum insulin, serum glucose and on modified forced swimming test, a behavioural paradigm for depression in rats. The study involving co-administration of sub-active doses of glimepiride, a K(+) channel blocker and chromium picolinate on blood glucose levels and modified forced swimming test was also performed to probe any role of K(+) channels in its antidiabetic and antidepressants effects. Streptozotocin (55 mg/kg, intraperitoneally) was injected in rats to induce diabetes (Type 1). After a week, chromium picolinate (8 microg/ml in drinking water) was administered for 4 weeks. Normal rats received similar drug treatment. The sub-active doses of chromium picolinate (4 microg/ml in drinking water) and glimeperide (2.5 mg/kg, orally) were co-administered and their effects on modified forced swimming test and on glucose levels were measured. Chromium picolinate (8 microg/ml in drinking water) produced hypoglycaemia in diabetic and normal rats. It had no effects on the streptozotocin-induced reduction in insulin levels. Chromium picolinate (8 microg/ml in drinking water) increased swimming with subsequent decrease in immobility. The sub-active doses of chromium picolinate and glimeperide showed significant additive effects in modified forced swimming test and reduction in serum glucose concentrations, though statistically insignificant. In conclusion chromium picolinate shows antidepressant action on modified forced swimming test affecting only swimming that suggests serotonergic pathways involvement. The additive effects on swimming in modified forced swimming test and reduction in serum glucose levels shows involvement of K(+) channels in antidiabetic and antidepressant actions of chromium picolinate.

Animals↗

Comparison of the adsorption ability between tryptophan and modified tryptophan columns.

Immunoadsorption therapy (IAT) using the tryptophan column (TR:TR-350, Asahi Medical Co., Tokyo, Japan) is used for patients with Guillain-Barré syndrome or Fisher's syndrome. Recently, a modified tryptophan column (modified TR:TR-350S, Asahi) was developed to reduce adsorption of fibrinogens. However, it is not clear whether the new column can effectively adsorb the antiganglioside antibodies. We treated 2 patients with Guillain-Barré syndrome, 1 patient with Fisher's syndrome, and 1 patient with Bickerstaff's brainstem encephalitis by IAT using the TR and the modified TR. Samples were taken from the inlet and outlet of the affinity column. We compared the adsorption ability of antiganglioside antibodies between the TR and modified TR. The modified TR adsorbed antiganglioside antibodies less effectively than the TR. No significant bleeding was observed in the patients during each session. Furthermore, results of the clinical study were confirmed by batchwise adsorption test. We propose that the modified TR should not be used for treating patients with Guillain-Barré syndrome and related disorders.

Adsorption↗

Physiological responses of horses competing at a modified 1 star 3-day-event.

The impending 1996 summer Olympic 3-day-event in Atlanta has focused attention on the need to determine what modifications to the demanding Endurance Test will be required to ensure safety of the horses competing. Three groups of horses participated in a Field Trial held in August of 1994 in northern Georgia to determine the safety and feasibility of conducting a modified 3-day-event in hot, humid weather. One group (TD) completed a modified 1 Star 3-day-event test, a control group (HT) completed a Horse Trial identical to the modified 1 Star test except for the omission of Phases B and C and the third group (E), comprised of European horses, completed the modified 1 Star test with a longer, faster Phase C than was used for TD. During the Endurance Test, the ambient temperature and relative humidity ranged from 24.3 degrees C and 98.9% in the morning to 30.2 degrees C and 51.6% in the afternoon. No horse failed to complete the Trial because of heat stress or fatigue. There were no significant (P < 0.05) differences detected in heart rate, rectal temperature, respiratory rate or net weight loss between HT and TD horses at any observation time. The highest rectal temperature recorded at the end of Phase C was 39.6 degrees C. These findings suggest that the modified 1 Star Endurance Test was as well tolerated by American horses as the control Horse Trial test. Rectal temperature was significantly higher for E than for TD or HT at the finish of Phase C. European horses had significantly greater decreases in weight than HT and TD at the end of Phases C and D and the next day. These findings probably reflect the faster and longer work effort of E horses during Phase C. Modification of Phase C and the rest-pause to ensure that recovery and heat dissipation occurred before the start of Phase D resulted in a 3-day-event that was safe for horses. The Field Trial provides a model for designing a modified Olympic Endurance Test. If the 1996 Olympic 3-day-event is held in hotter and more humid weather than the Field Trial, additional modifications to the Endurance Test (decreased distances, speeds and numbers of jumping efforts) will probably be required to ensure safety of competing horses.

Animals↗

A modified enzyme-linked immunosorbent assay for measurement of antibody responses to meningococcal C polysaccharide that correlate with bactericidal responses.

The standardized enzyme-linked immunosorbent assay (ELISA) for measurement of serum immunoglobulin G (IgG) antibody responses to meningococcal C polysaccharide has been modified to employ assay conditions that ensure specificity and favor detection primarily of high-avidity antibodies. The modified and standard assays were used to measure IgG antibody concentrations in sera of toddlers vaccinated with meningococcal polysaccharide vaccine or a meningococcal C conjugate vaccine. The results were compared to the respective complement-mediated bactericidal antibody titers. In sera obtained after one or two doses of vaccine, the correlation coefficients, r, for the results of the standard assay and bactericidal antibody titers were 0.45 and 0.29, compared to 0.85 and 0.87, respectively, for the modified assay. With the standard assay, there were no significant differences between the geometric mean antibody responses of the two vaccine groups. In contrast, with the modified assay, 5- to 20-fold higher postvaccination antibody concentrations were measured in the conjugate than in the polysaccharide group. Importantly, the results of the modified assay, but not the standard ELISA, paralleled the respective geometric mean bactericidal antibody titers. Thus, by employing conditions that favor detection of higher-avidity IgG antibody, the modified ELISA provides results that correlate closely with measurements of antibody functional activity that are thought to be important in protection against meningococcal disease.

Antibodies, Bacterial↗

Characterization of a heat-modifiable outer membrane protein of Haemophilus somnus.

In immunoblot analysis, a murine monoclonal antibody (MAb), 27-1, which was produced to an outer membrane protein (OMP) of Haemophilus somnus, showed that a major OMP is heat modifiable, having a molecular mass of 28 kDa when the N-lauroylsarcosine-insoluble OMP preparation was solubilized at 60 degrees C and a mass of 37 kDa when the OMP preparation was solubilized at 100 degrees C. The heat-modifiable OMP reacted intensely with convalescent sera obtained from calves with experimental H. somnus pneumonia in immunoblot analysis. Immunoelectron microscopic and antibody absorption studies revealed that the MAb 27-1 epitope was not surface exposed on the intact bacterium. However, a decrease in antibody reactivity to the heat-modifiable OMP in immunoblot analysis after absorption of convalescent serum with intact bacterial cells of H. somnus suggests that a surface-exposed portion of the heat-modifiable OMP is expressed on the intact bacterium. MAb 27-1 reacted with 45 of 45 strains of H. somnus tested in immunoblot analysis. The apparent molecular mass of the antigen varied among strains, and five reactivity patterns demonstrated by MAb 27-1 were observed. MAb 27-1 also reacted with six species in the family Pasteurellaceae, Escherichia coli, and Salmonella dublin, but not with the other eight species of gram-negative bacteria. The heat-modifiable OMP of H. somnus showed immunological cross-reactivity with the OmpA protein of E. coli K-12 and significant N-terminal amino acid sequence homology with the OmpA proteins of gram-negative bacteria. We conclude that a major, 37-kDa heat-modifiable OMP of H. somnus, which elicits an antibody response in H. somnus-infected animals, is a common antigen among H. somnus strains tested and is structurally related to the OmpA protein of E. coli.

Amino Acid Sequence↗

Immunological detection of the Kanagawa phenomenon of vibrio parahaemolyticus on modified selective media.

Selective media for Vibrio parahaemolyticus, BTB-Teepol agar and modified arabinose-ammonium sulfate-cholate agar, were modified for use in immunological detection of the thermostable direct hemolysin produced by this organism. The modified BTB-Teepol agar and modified arabinose-ammonium sulfate-cholate agar were both found to be useful for the modified Elek test and immunohalo test with antiserum (or immunoglobulin G) against the thermostable direct hemolysin. With these modified media it is possible to isolate V. parahaemolyticus and identify the Kanagawa phenomenon on a single plate and thus save time in obtaining results.

Culture Media↗