Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Meridians”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Structure and packing of dry elastoidin: a collagen phase change.

Wide angle X-ray patterns of wet shark fin elastoidin always show a very intense meridional streak arising from the small angle diffraction pattern. When the fin ray spicules (ceratotrichia) are permitted to air dry, the pattern departs from the meridian. Studies show that the dry spicules are, in fact, radially anisotropic. Diffraction patterns taken with the X-ray beam perpendicular to the edge of the ribbon-shaped spicules have two distinct arms (with an interarm angle of as much as 70 degrees), while the small angle streak taken with the beam perpendicular to the ribbon face is generally either on the meridian, or is so weak that it cannot be resolved from the background. An analysis of the intensities of the small angle diffraction pattern of the dry form indicate that it has essentially a normal dry collagen structure. Addition of methanol serves only to expand the dry structure, without reversal of the phase transition. These data can be interpreted by postulating that as the wet structure collapses during drying, the collagen molecules tilt in a direct perpendicular to the face of the ribbon, forming domains of molecules with similar axial orientation. The implication is that the original interactions are lost, and the new structure is formed by overlaps between formerly non-interacting molecules.

Collagen↗

Two visual areas located in the middle suprasylvian gyrus (cytoarchitectonic field 7) of the cat's cortex.

Neuronal properties and topographic organization of the middle suprasylvian gyrus (cortical cytoarchitectonic field 7) were studied in three behaving cats with painlessly fixed heads. Two main neuronal types were found within this field. Type 1 neurons occupied the lateral part of the field and bordered representation of directionally selective neurons of the lateral suprasylvian visual area by vertical retinal meridian. Type 1 neurons had elongated and radially oriented receptive fields located in the lower part of contralateral visual field. Type 1 neurons preferred stimuli moving out or to the centre of gaze at a low or moderate speed, and many of them were depth selective. The responses were enhanced by attention, oriented to the presented stimulus. Medial part of the field 7 along the border with the area V3 was occupied by neurons with not elongated receptive fields (type 2). These neurons preferred moderate and high speeds of motion, and gratings of proper spatial frequency and orientation were effective stimuli for them. Border between representations of type 2 and type 1 neurons coincided with projection of horizontal retinal meridian. At the rostral and caudal borders of the field 7 abrupt changes of neuronal properties took place. Neurons which abutted field 7 anteriorly and posteriorly resembled hypercomplex cells and their small receptive fields were located in the central part of the visual field. Topographical considerations and receptive field properties allowed us to conclude that the medial part of the field 7 (included type 2 neurons) is functionally equivalent to the area V4 in the cortex of primates, while the lateral part (type 1 neurons) may correspond to the area V4T.

Animals↗

Parametric studies on electroacupuncture-like stimulation in a rat model: effects of intensity, frequency, and duration of stimulation on evoked antinociception.

We have found that electroacupuncture-like stimulation of defined sites in the hindlimb of the rat inhibits a nociceptive withdrawal reflex. The lightly anaesthetized rat was used and tall withdrawal from a noxious radiant heat stimulus was the nociceptive reflex. Standard stimulation of hindlimb meridian points femur-futu (ST-32), fengshi (GB-31), and zusanli (ST-36) consisted of a 2-ms square voltage pulse at 4 Hz for a duration of 20 min, applied at 20 times the threshold to evoke muscle twitch. This produced two types of inhibition of the reflex; one was an increase in the latency of up to 80% during the stimulation, termed the brief antinociception, and the other was a post stimulation increase of up to 60% lasting greater than 1 h, termed the persistent antinociception. When the stimulus intensity was reduced to 10 times threshold, the latency during stimulation increased up to 50%, but the persistent response did not occur. Stimulation at threshold produced neither effect. When the train duration was altered, 10 min of stimulation produced only the brief effect, whereas 40 min of stimulation produced both effects, although the persistent effect lasted only 20 min. Stimulation at 6 Hz produced responses similar to those at 4 Hz, whereas stimulation at 2 Hz produced smaller effects. At 8 Hz, only the brief antinociception was elicited. With a pulse duration of 0.2 ms, the brief response was observed but the persistent response was markedly attenuated, whereas 5 ms produced responses similar to those with 2 ms. These data suggest that high-intensity, low-frequency electrical stimulation of meridian points in the rat hindlimb produces both brief and persistent antinociceptive effects on the tail withdrawal reflex, and both effects are dependent upon the parameters of stimulation. The persistence of the latter effect beyond the period of stimulation suggests events occurring after direct synaptic activity, possibly mediated via plastic changes at spinal and/or supraspinal levels.

Animals↗

Paracentral photoablations to correct higher grades of naturally occurring astigmatism.

PURPOSE: To evaluate the efficacy of paracentral ablations in treating higher degrees of naturally occurring myopic and hyperopic astigmatism. SETTING: Augenklinik, Kreiskrankenhaus Bad Hersfeld, Germany. METHODS: Twenty-five eyes (7 with hyperopia, 18 with myopia) with naturally occurring corneal astigmatism greater than 1.75 diopters (D) were treated by excimer laser. The mean refractive cylinder was -4.05 D +/- 1.46 (SD) (range -1.75 to -7.00 D). The intention was to reduce the astigmatism without consideration of the spherical refractive error. Two paracentral ablations were performed by photorefractive keratectomy with treatment zones of 3.5 mm in the flatter meridian of the cornea. Objective refraction, best corrected visual acuity (BCVA), changes in corneal radius, development of haze, and regression were recorded. RESULTS: The paracentral ablations induced a steepening of the corneal radius in the flatter meridian from 8.12 mm (mean preoperative value) to 7. 84 mm (mean postoperative value) and thus reduced the mean refractive cylinder to -1.12 +/- 0.82 D (range 0.00 to - 3.00 D), corresponding to a mean reduction of 78%. No eye experienced a loss of Snellen lines. The preoperative BCVA (mean 20/25; range 20/50 to 20/20) was unchanged postoperatively CONCLUSIONS: Paracentral ablations resulted in a stable corneal curvature immediately after epithelial healing, with a moderate regression over time. Paracentral ablations with the excimer laser appear to be a safe and effective method to correct higher grades of corneal astigmatism.

Adult↗

Optimal incision sites to obtain an astigmatism-free cornea after cataract surgery with a 3.2 mm sutureless incision.

PURPOSE: To determine the optimal incision to eliminate astigmatism after cataract extraction. SETTING: Hara Eye Hospital, Utsunomiya, Japan. METHODS: Patients having cataract extraction through a 3.2 mm corneal limbal incision without limbal sutures were divided into 2 groups. Group 1 comprised 98 eyes of 80 patients without preoperative astigmatism and Group 2, 72 eyes of 62 patients with no astigmatism postoperatively. In Group 1, the incisions that caused postoperative corneal changes were retrospectively evaluated. In Group 2, the types of incisions that induced an astigmatism-free cornea postoperatively were retrospectively studied. Patients were examined preoperatively and 6 months postoperatively. RESULTS: In Group 1, 23 of 40 eyes (57.5%) with an incision between 9 and 12 o'clock (BENT incision) and 10 of 58 eyes (17.2%) with an incision at 12 o'clock remained astigmatism free postoperatively (P <.0001). One eye (2.5%) with a BENT incision and 17 (29.3%) with a 12 o'clock incision had astigmatism greater than 1.0 diopter (D) postoperatively (P <.001). In Group 2, 72 eyes had less than 1.2 D of preoperative astigmatism. No eye with more than 1.2 D of astigmatism was astigmatism free postoperatively, even when the incision was made at the steepest meridian. CONCLUSIONS: The results indicate that to reduce astigmatism in eyes with preoperative astigmatism of 0.5 D or more, a limbal 3.2 mm BENT incision should be placed at 10:30 o'clock. To prevent astigmatism postoperatively, the incision should be placed at the steepest meridian in eyes with preoperative astigmatism greater than 0.5 D; for preoperative astigmatism greater than 1.2 D, a 3.2 mm incision at the corneal limbus is insufficient and a wider incision or an additional incision is required.

Aged↗

Intracorneal rings for the correction of pellucid marginal degeneration.

We report a case of Intacs(R) (KeraVision) implantation for the correction of pellucid marginal degeneration (PMD). Preoperatively, the patient's uncorrected visual acuity (UCVA) was 0.05, the best spectacle-corrected visual acuity (BSCVA) was 0.1, and the refraction was -2.00 -7.00 x 90 in the right eye. The flattest meridian (K1) measured 43.8@104 and the steepest meridian (K2), 51.3@14. Ultrasound pachymetry revealed a thin cornea of 420 micrometers. One month postoperatively, the UCVA was 0.2, the BSCVA was 0.5, and the refraction was -8.00 -7.00 x 50. Contact lens best corrected visual acuity was 0.9; 6 months postoperatively, it improved to 1.0. The use of Intacs to treat PMD seems to be viable and improves visual acuity. The residual error can be corrected with contact lenses.

Adult↗

Calculating the surgically induced refractive change following ocular surgery.

Calculating the surgically induced refractive change following ocular surgery is important for evaluating the results of keratore-fractive procedures, smaller incisions and various wound closures for cataract surgery, and the effect of suturing techniques and suture removal following corneal transplant surgery. We present a ten-step method of calculating the spherical- and cylindrical-induced refractive change in a manner suitable for a programmable calculator or personal computer. Several applications are given including (1) adding the overrefraction to the spectacle correction, (2) determining the surgically induced refractive change from the preoperative and postoperative refractions, (3) determining the surgically induced refractive change from the K-readings, (4) rotating axes, (5) determining the power at meridians oblique to the principal meridians of a spherocylinder, (6) determining the coupling ratio, and (7) averaging axes. Standard methods for calculating and reporting aggregate results are also given.

Astigmatism↗

Corneal topographic analysis of superolateral incision cataract surgery.

Using corneal topography, we compared the corneal shape changes following superolateral incision cataract surgery with those following conventional superior incision surgery. In our superolateral incision procedure, a 6.5 mm limbal incision was made from the 9 o'clock to 11 o'clock meridians to avoid incising the superior limbus. One hundred four patients were divided into two groups; Group 1 comprised 66 patients who had surgery using the superolateral approach; Group 2 comprised 38 patients who had surgery using the superior approach. The corneas were examined by keratometer and topographic modeling system preoperatively, and at one week and one, three, and six months postoperatively. Keratometric measurements showed that surgically induced astigmatism (SIA) in Group 1 was significantly less than that in Group 2 throughout the six-month observation. The standard SIA deviation in Group 1 was also smaller than that in Group 2, indicating a smaller degree of variability in the superolateral incision surgery. In the corneal topographic analysis, a color-coded map averaging all the Group 1 corneas at each interval showed a slight steepening in the central cornea in the 10 o'clock meridian one week after surgery. This surgically induced steepening disappeared by one month, and the corneal shape recovered its preoperative shape. In contrast, the Group 2 averaged map showed a marked steepening of the upper and lower corneas. The steepening gradually decreased but remained until three months after surgery. Superolateral incision surgery induced a smaller degree of change in the corneal shape, as well as in SIA, than superior incision surgery. The postoperative corneal shape changes disappeared rapidly after the superolateral incision, and the corneal shape soon stabilized and recovered its preoperative shape.

Aged↗

Evaluating surgically induced astigmatism by Fourier analysis of corneal topography data.

PURPOSE: To evaluate surgically induced astigmatism using Fourier harmonic series analysis of corneal topography data. SETTING: Aarhus Kommunehospital, Aarhus University, Denmark. METHODS: We evaluated the results of 46 phacoemulsifications with a 4 or 6 mm scleral tunnel sutureless incision based on the axis of the steepest meridian. We performed conventional keratometry and corneal topography before and up to 1 month after surgery. Using Fourier analysis, the corneal topographic images were broken into spherical power, regular astigmatism, and nonregular astigmatism for individual or aggregate analysis of surgically induced astigmatism. The induced refractive change (average of the difference between preoperative and postoperative corneal topographies) was analyzed and normalized according to the surgical meridian and to right/left eye. RESULTS: Regular astigmatism calculated by Fourier analysis of mires from the keratometer zone correlated well with conventional keratometry readings. Surgery induced a localized flattening in the superior region and a with-the-rule regular astigmatism component in the central area. CONCLUSION: Surgically induced corneal topography changes can be analyzed by Fourier series harmonic analysis, allowing aggregate data to be broken into optically meaningful quantities.

Adult↗

Vector analysis of astigmatism changes by flattening, steepening, and torque.

PURPOSE: To understand the effect of astigmatism surgery by analyzing astigmatic changes according to their component parts. SETTING: Cheltenham Eye Centre, Melbourne, Australia. METHODS: The component parts of the astigmatic changes considered were flattening, steepening, clockwise torque, and counterclockwise torque. Calculations to determine the astigmatic change were performed by vector analysis using rectangular coordinates after doubling the astigmatism and surgical vector axes. A reference axis was used for the resolution of astigmatic change to ascertain its effect along a selected meridian. RESULTS: When correcting astigmatism, the orientations of incisional (tissue addition) or nonincisional (tissue ablation) techniques in any cornea are at right angles to each other. Since differences exist in the measured astigmatism depending on whether it is measured topographically or by manifest refraction, an on-axis correction in one will occur with an off-axis effect in the other. The net result is a reduced flattening effect and a proportionately increased torque effect for the off-axis component. CONCLUSION: When treatment is applied off one of the four primary axes, the treating vector can be resolved into its component parts of flattening, steepening, and torque. Analyzing changes in this way provides a uniform means of assessing astigmatic changes for all types of cataract and refractive surgery and quantifies the flattening effect when treatment is applied off the intended meridian.

Astigmatism↗

Changes in computerized videokeratography induced by artificial tears.

PURPOSE: To analyze the effect of several standard artificial tear preparations on computerized videokeratographic measurements. SETTING: Cullen Eye Insitute, Baylor College of Medicine, Department of Ophthalmology, Houston, Texas, USA. METHODS: We evaluated one eye each in 18 normal volunteers. Using the EyeSys Corneal Analysis System (EyeSys Technologies), we obtained corneal topographic measurements at baseline and 0.5, 1, 2, 3, 4, 5, 6, 8, and 10 minutes after instillation of the following preparations: balanced salt solution, Tears Naturale II, Tears Naturale Free, Cellufresh, Celluvisc, HypoTears, and HypoTears PF. We analyzed changes in curvature of the keratographic rings at radii 1 to 5 mm and changes in keratometric-equivalent astigmatic power and meridian. RESULTS: All preparations except HypoTears and Tears Naturale II induced statistically significant, time-dependent changes in mean corneal power in the central 5 mm corneal zone compared with baseline measurements (P < .05). The relationship between change in dioptric power over time varied with preparation type and was nonlinear in nature. In all cases, the mean induced change was < or = 0.5 diopter. Except for Celluvisc, tear administration produced minimal changes in the values of corneal astigmatic power or meridian. CONCLUSION: When performing serial measurements of mean corneal power, the greatest consistency was achieved with no tears or with instillation of HypoTears or Tears Naturale II.

Astigmatism↗

Computerized topography of selective versus all-suture release to manage high astigmatism after cataract surgery.

PURPOSE: To compare the efficacy of selective suture release (SSR) with all-suture release (ASR) in controlling corneal astigmatism after cataract surgery. SETTING: Sight Saver's Cornea Training Centre, L.V. Prasad Eye Institute, Hyderabad, India. METHODS: This prospective, randomized study evaluated the effect on astigmatism of two techniques of suture release in 30 patients with more than 3.00 diopters (D) of corneal astigmatism after cataract surgery. All patients had interrupted sutures with well-healed wounds. Fifteen patients had ASR irrespective of the location of the steep meridian. In the other 15, only the suture located in the steep meridian was selectively released. The pattern of decay of astigmatism after suture release was studied using computerized videokeratography. RESULTS: Mean pretreatment corneal cylinder was 6.30 D +/- 2.72 (SD) in the ASR group and 6.95 +/- 1.67 D in the SSR group. In the ASR group, corneal cylinder dropped to 3.70 +/- 1.15 D immediately after suture release and further decreased to 1.82 +/- 0.66 D at 1 week (P < .001). In the SSR group, astigmatism swung erratically to the adjoining sutures and decreased unpredictably at an average of 1.32 +/- 2.00 D with each suture release. CONCLUSION: The ASR technique was more predictable and less cumbersome than the SSR method.

Aged↗

Computer-assisted videokeratography to measure changes in astigmatism induced by sutureless cataract surgery.

PURPOSE: To compare the visual outcome, change in surgically induced astigmatism, and corneal thickness after sutureless cataract surgery through either a scleral tunnel or clear corneal incision. SETTING: Department of Ophthalmology, Kangnam St. Mary's Hospital, Catholic University Medical College, Seoul, Korea. METHODS: This retrospective study evaluated 79 eyes of 64 patients who had cataract surgery using a 6.0 mm scleral tunnel incision (Group 1, n = 20 eyes), 3.1 mm clear corneal incision at the 10 o'clock position (Group 2, n = 35 eyes), or 3.1 mm clear corneal incision at the 10 o'clock position (Group 3, n = 24 eyes). Changes in surgically induced astigmatism were analyzed using computer-assisted videokeratography (CVK) 1 day, 8 weeks, and 6 months postoperatively. RESULTS: Eleven eyes (55.0%) in Group 1, 15 (42.8%) in Group 2, and 11 (48.5%) in Group 3 had an uncorrected visual acuity of 20/40 or better 1 day postoperatively. The CVK measurements showed significantly more flattening at radial distances of 0.75, 1.50, and 2.50 mm along the 90 degree semimeridian in Group 2 than in Group 1 (P < .05) 1 day after surgery; in Group 3, flattening along the incisional semimeridian fell between the amounts in Groups 1 and 2. At 8 weeks, the amount of flattening decreased in all groups, and the differences between groups were not statistically significantly different (P > .05). In the CVK pattern, corneal flattening along the incisional meridian was narrower and longer in Groups 2 and 3 than in Group 1. CONCLUSION: Localized flattening along the incisional meridian was prominent temporally after clear corneal incision surgery. However, there was no difference in early visual rehabilitation between the clear corneal and scleral tunnel incision groups.

Adult↗

Results of laser in situ keratomileusis in hyperopic compound astigmatism.

PURPOSE: To evaluate the efficacy and safety of steepening the flatter meridian with laser in situ keratomileusis (LASIK) to correct hyperopic compound astigmatism using the Schwind-Keratom laser with the MultiScan System and the active tracking system for centering the ablation. SETTING: Instituto Barraquer de América, Bogotá, Colombia. METHODS: From June to December 1997, LASIK was performed in 111 eyes to correct congenital hyperopic compound astigmatism. Preoperatively, the mean spherical equivalent was +2.58 diopters (D) (range +1.50 to +3.50 D) in 37 eyes (low dioptric group), with a mean sphere of +3.66 D (range +1.75 to +5.50 D) and a mean cylinder of -2.11 D (range -0.50 to -5.00 D); +4.71 D (range +3.51 to +6.00 D) in 50 eyes (middle dioptric group), with a mean sphere of +5.58 D (range +4.00 to +7.00 D) and a mean cylinder of -1.83 D (range -0.50 to -4.50 D); and +7.26 D (range +6.01 to +10.00 D) in 24 eyes (high dioptric group), with a mean sphere of +8.25 D (range +6.50 to +10.00 D) and a mean cylinder of -1.98 D (range -0.50 to -4.00 D) in 24 eyes. Postoperative results were measured at 10 days and 6 months. RESULTS: At 6 months, the mean residual subjective spherical defect was +0.32 D (range -0.50 to +1.00 D) in the low dioptric group, with a mean cylinder of -0.61 D (range 0.00 to -1.75 D); all eyes were within +/- 1.00 D of emmetropia. The mean defect was +0.82 D (range 0.00 to +2.50 D) in the middle dioptric group, with a mean cylinder of -0.61 D (range 0.00 to -2.50 D); 80% of eyes were within +/- 1.00 D of emmetropia. The mean defect was +1.10 D (range -0.50 to +3.00 D) in the high dioptric group, with a mean cylinder of -1.39 D (range 0.00 to -3.25 D); 77% of eyes were within +/- 1.00 D of emmetropia. In the study group as a whole, 90% of eyes had a cylinder correction within +/- 1.00 D of emmetropia. Uncorrected visual acuity (UCVA) was 0.50 (20/40) or better in 23.4% of eyes preoperatively and 0.50 (20/40) or better in 71.0% 6 months postoperatively. CONCLUSIONS: Steepening the flatter meridian with the MultiScan System safely and effectively corrected hyperopic astigmatism. The rapid recovery of UCVA was due not only to correction of the ametropia, but also to the centering provided by the active tracking system.

Adolescent↗

Keratoconus evaluation using the Orbscan Topography System.

PURPOSE: To evaluate corneal topography in a series of keratoconus patients using the Orbscan Topography System. SETTING: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. METHODS: Seventy-one eyes of 38 patients with keratoconus were evaluated. Quantitative topographic parameters were analyzed with special reference to the central point of the cornea, the apex (the point with maximum reading on the anterior elevation best-fit sphere map), and the thinnest point. Evaluation included location, elevation (compared to a best-fit sphere), pachymetry, tangential curvature, and composite curvature. The mirror-image symmetry between the right and left eyes of a patient was also investigated. RESULTS: Mean patient age was 31.2 years +/- 12.2 (SD). Thirty-three patients (86.8%) had bilateral keratoconus and 5 (13.2%), unilateral keratoconus. Most cones (68/71) were located in the inferior temporal quadrant; 3 were above the horizontal meridian. Mean distance between the apex and the thinnest point was 0.917 +/- 0.729 mm (P < .001). The correlations between apex elevation and apex composite curvature and apex tangential curvature were high (r = 0.94 and r = 0.91, respectively; P < .001). In right and left eyes, there was a correlation between the apex and the thinnest point semi-meridians (r = 0.47 and r = 0.65, respectively; P < .05) but not between the radii of the apex and the thinnest point (r = 0.21 and r = 0.24, respectively). CONCLUSIONS: The Orbscan system can provide useful and accurate information in defining the morphology of keratoconus and detecting subtle topographic changes present in early keratoconus. It may also improve the results of contact lens fitting and surgical management.

Adolescent↗

Development of the primate retinal vasculature.

Human and macaque retinae have similar retinal vascular anatomy. The general features of the retinal vascular anatomy of these two primates have much in common with more widely studied animal models such as rat and cat. However, primates are unique amongst mammals in having a region in temporal retina specialized for high visual acuity, which includes the fovea centralis (or 'fovea'). Several features distinguish the fovea from other parts of the retina, including a very high local density of cone photoreceptors, a high density of inner retinal cells during development, and an absence of retinal blood vessels. The retinal vascular complex comprises a number of cell types, in addition to vascular endothelial cells, including pericytes, microglia, astrocytes-none of which is intrinsic to the retina. In addition, amacrine-like cells make bouton-like associations with retinal vessels and may be involved in the autoregulation of blood flow. During development endothelial cells 'invade' the retina, accompanied by a population of microglial cells; glial fibrillary acidic protein (GFAP)-immunoreactive astrocytes are also seen associated with the developing vasculature, and are in advance of the vascular front by a few hundred microns. Recent findings indicate that astrocytes at the vascular front proliferate in response to factors released by endothelial cells, including leukemia inhibitory factor. Better understood is the role of GFAP-immunoreactive astrocytes just in advance of the developing vessels. These astrocytes are sensitive to hypoxia and in response release vascular endothelial growth factor (VEGF) which in turn promotes the migration, differentiation and proliferation of vascular endothelial cells. This hypoxia/VEGF-mediated process of migration, proliferation and differentiation appears common to the retinae of a variety of species, including human. However, in human and macaque retina, different mechanisms appear to govern the development of the retinal vessels growing along the horizontal meridian of the retina towards the central area, which contains the fovea. Despite the relatively advanced state of differentiation and maturation of cells in the central area compared with the periphery, the growth of retinal vessels into the central area has been described as 'retarded', and the incidence of cell proliferation associated with these vessels is lower than in peripheral vessels. Furthermore, neither retinal vessels nor their accompanying astrocytes grow into a circumscribed region which, at a later stage, develops into the foveal depression. These observations suggest that molecular markers define the foveal region and inhibit cell proliferation and vascular growth at the fovea and, perhaps, along the horizontal meridian. The findings also suggest that at the fovea, the retina is adapted morphologically to its blood supply, since in the vicinity of the fovea, the development of retinal vessels is retarded or inhibited. The limitations on vascularization of central retina has implications for its vulnerability to degenerative changes, as seen in age-related macular degeneration.

Animals↗

Clinical performance of polynomial lenses versus tri-curve lenses. II: ocular responses.

This study, which was a continuation of the previous one, aimed to determine the subjective and objective responses after wearing polynomial and tri-curve rigid gas permeable (RGP) lenses over a period of 6 months. Subjects were divided into two groups, each of which wore either one of these lens designs and 17 of 22 subjects completed the 6-month study. Subjective responses were assessed by a questionnaire while the objective responses including vision, contrast sensitivity, lens fitting and the corneal integrity, corneal thickness and endothelial cell morphology were assessed by the examiner. There were no significant differences in the subjective ratings, vision, contrast sensitivity and the lens fitting between the two groups. Except for the p-value (p) and the apical radius (r(o)) along the steepest meridian and the coefficient of variation in cell size in the inferior corneal endothelium, there were no significant changes in the palpebral aperture size, the p-value and r(o) along the flattest meridian, corneal thickness and the other endothelial cell variables after the 6-month study period. The poor success and high dropout rates of RGP lens wear in this study stress the importance and need for further investigations of such lenses.

Journal Article↗

The reproducibility of videokeratoscope measurements as applied to the human cornea.

To be useful in contact lens fitting, the videokeratoscope (VK) must be able to provide the practitioner with credible data on the vertex radius and central topography, or 'shape, of the patient's cornea. For this purpose, it is desirable that the measured value of the former should be credible at the level of 0.05 mm. In order to examine the accuracy, repeatability and reproducibility of the corneal dimensions provided by the videokeratoscope, eight eyes were measured on four different EyeSys systems at four independent sites. The order of measurement was random at each site. This amounted to a balanced uniform-level precision experiment ('ring test') of the VK instruments as defined in International Standard ISO 5725. The resulting data were analysed using the statistical procedures given in this Standard to provide a formal statement of the measurement precision of the EyeSys VK system. Based on this study, the estimated measurement precision of the EyeSys videokeratoscope as applied to the latter principal meridian of the normal human cornea is: Vertex radius: repeatability standard deviation, S(R)=0.0805, reproducibility standard deviation, S(R)=0.1041. p value: repeatability standard deviation, S(r)=0.0473, reproducibility standard deviation, S(R)=0.0574. The estimated measurement precision for the steeper principal meridian is: Vertex radius: repeatability standard deviation, S(r)=0.0771; reproducibility standard deviation, S(R)=0.1015. p value: repeatability standard deviation, S(R)=0.0698; reproducibility standard deviation, S(R)=0.0749.

Journal Article↗