Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Isotopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Highest isotope count does not predict sentinel node positivity in all breast cancer patients.

BACKGROUND: Radioisotope mapping is an essential technical component of sentinel lymph node (SLN) biopsy, and most authors define isotope success by an arbitrary threshold SLN-to-background ratio. Few studies have examined the degree to which the relative level of SLN counts correlates with the presence of metastasis. Having removed the SLN with the highest counts, how far should the surgeon persist in removing additional SLN which contain much lower levels of isotope? METHODS: We performed SLN biopsy, using both radioisotope and blue dye, in 2285 consecutive patients with stage I-II breast cancer. Successful isotope localization was defined as an ex vivo SLN-to-axillary background count ratio of at least 4:1, and enhanced pathologic analysis (serial sections and immunohistochemistry) was used throughout. RESULTS: Among the 1566 patients with more than one SLN site identified, the SLN contained metastasis in 463 (30%). In 369 (80%) of these SLN-positive cases, the SLN with the highest count contained tumor, but in 94 (20%) it was benign. Among these 94: (1) the counts of the hottest benign SLN exceeded those of the histologically positive SLN by a ratio of at least 10:1 in 31% (29 of 94) of cases, (2) the counts of the positive SLN were < 4:1 those of the axillary background in 16% (15 of 94) of cases, and (3) blue dye failed to identify 27% of positive SLN. No optimum ratio of SLN-to-SLN or SLN-to-background counts identified the positive SLN in all cases. CONCLUSION: Although the SLN with the highest counts is positive in 80% of breast cancer patients with multiple SLN, neither a relatively high isotope count nor the presence of blue dye consistently predict SLN positivity in all breast cancer patients. For maximum accuracy, SLN biopsy requires (1) the removal of all nodes containing isotope regardless of the relative magnitude of counts, (2) the concurrent use of blue dye to salvage those procedures in which isotope fails, and (3) the removal of all clinically suspicious non-SLN.

Adolescent↗

Quantitative determination of oxidative base damage in DNA by stable isotope-dilution mass spectrometry.

For understanding of the role of oxidative DNA damage in biological processes such as mutagenesis and carcinogenesis, it is essential to identify and quantify this type of DNA damage in cells. This can be achieved by gas chromatography/mass spectrometry. The present study describes the quantification of modified bases in DNA by isotope-dilution mass spectrometry with the use of stable isotope-labeled analogues as internal standards. A number of isotopically labeled DNA bases were synthesized. The mass spectra of their trimethylsilyl derivatives were recorded. Calibration plots were obtained for known quantities of modified bases and their isotope-labeled analogues. Quantification of various modified DNA bases by isotope-dilution mass spectrometry was demonstrated in isolated chromatin exposed to ionizing radiation. The results indicate that gas chromatography/stable isotope-dilution mass spectrometry is an ideally suited technique for selective and sensitive quantification of modified bases in DNA.

Chromatin↗

Solvent isotope effects on NMR spectral parameters in high-spin ferric hemoproteins: an indirect probe for distal hydrogen bonding.

The influence of solvent isotope composition on 1H-NMR resonance position and linewidth of heme methyls has been investigated for a variety of high-spin ferric hemoproteins for the purpose of detecting hydrogen-bonding interactions in the heme cavity. Consistently larger hyperfine shifts and paramagnetic linewidths in 2H2O than 1H2O are observed for metmyoglobins and methemoglobin possessing a coordinated water molecule. The analysis of the dynamics of labile proton exchange in sperm whale metmyoglobin, and the absence of any isotope effects in the five-coordinate Aplysia metmyoglobin, indicate that the significant axial modulation of heme electronic structure by solvent isotope is consistent with arising from distal hydrogen-bonding interactions. The presence or absence of similarly large isotope effects on shifts and linewidths in other hemoproteins, depending on the presence of a bound water in the distal heme pocket, suggests that this isotope effect can serve as a probe for the presence of such bound water. The absence of any detectable isotope effect on either shifts or linewidths in resting-state horseradish peroxidase supports a five-coordinate structure with bound water absent from the vicinity of the iron.

Animals↗

Hydrogen isotope effects on the proton nuclear magnetic resonance spectrum of bovine ferricytochrome b5: axial hydrogen bonding involving the axial His-39 imidazole ligand.

The potential role of hydrogen bonding interactions in modulating the molecular and electronic structure of the active site of solubilized bovine ferricytochrome b5 has been investigated by monitoring solvent isotope effects on proton-NMR spectral parameters. It is observed that the hyperfine shifts of both the heme prosthetic group and one coordinated His are sensitive, while those for the other axial His and non-coordinated residues are insensitive, to 2H for 1H exchange. Two types of isotope influences are characterized; one whose chemical shift influence is time-resolved on the NMR time scale, and involves a single proton on one axial ligand, and a second effect which involves multiple protons, is not time resolved, and influences primarily the heme. A large isotope effect on the hyperfine shift is identified for the C beta H signals of His-39 but not His-63. The exchangeable ring NH of His-39 is assigned, and the pH influence on the exchange properties of heme pocket labile protons, when compared to the rate of base catalyzed averaging of the His-39 C beta H isotope effect, lead to the conclusion that the axial hydrogen bond which is responsible for this isotope effect is that between His-39 ring NH and Gly-42 carbonyl. The more rapid exchange of labile protons with solvent for His-63 than His-39 confirms a less solvent accessible and stronger hydrogen bonded His-39 than His-63. The stronger His-39-Gly-42 than His-63-Phe-58 hydrogen bond involving the ring NH leads to more extensive His-39 imidazolate character and hence a stronger iron-His-39 than iron-His-63 bond. The much larger hyperfine shifts for His-39 than His-63 imidazole ring non-labile protons support the stronger bonding of the former ligand, and account for the orientation of the rhombic magnetic axes by His-39 rather than His-63. The solvent isotope effect on the heme leads to rotation of the prosthetic group about the His-Fe-His bond by approximately 0.5 degrees so as to shorten the 7-propionate link to Ser-64. This suggests that the hydrogen bonds between the 7-propionate group and Ser-64 are responsible for the effect.

Animals↗

Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study.

OBJECTIVES: This study assessed the validity of a novel approach to myocardial perfusion scintigraphy that provides the opportunity to avoid the drawbacks of standard same-day rest/stress technetium-99m sestamibi myocardial perfusion studies by using separate-acquisition dual-isotope rest thallium-201 and exercise technetium-99m sestamibi single-photon emission computed tomography (SPECT). BACKGROUND: Standard same-day rest/stress technetium-99m sestamibi myocardial perfusion studies are cumbersome, associated with a potential decrease in perceived stress defect severity compared with thallium-201 due to the presence of rest technetium-99m sestamibi and may be unable to differentiate hibernating from infarcted myocardium. METHODS: The dual-isotope procedure was performed in 63 patients without previous myocardial infarction undergoing coronary angiography to evaluate sensitivity and specificity for coronary artery disease and in 107 patients with a low (< 5%) likelihood of coronary artery disease to evaluate normalcy rate. To validate defect reversibility, the dual-isotope SPECT study was compared with stress/rest technetium-99m sestamibi SPECT studies in a separate group of 31 patients with previous documented myocardial infarction who underwent a rest technetium-99m sestamibi study in addition to the dual-isotope SPECT study. RESULTS: In angiographic correlations, dual-isotope SPECT demonstrated high sensitivity for detecting patients with > or = 50% stenosis (91%, 55 patients) and > or = 70% stenosis (96%, 52 patients). In a small group of patients, high specificity was also observed (75% for < 50% stenosis [8 patients] and 82% for < 70% stenosis [11 patients]). A very high normalcy rate of 95% was also found. In the patient group assessed for defect reversibility, in zones with no previous myocardial infarction, segmental agreement for defect type between rest thallium-201 and rest technetium-99m sestamibi studies was 97% (kappa = 0.79, p < 0.001). In myocardial infarct zones, segmental agreement for defect type was 98% (kappa = 0.93, p < 0.001). Image quality was generally good to excellent. CONCLUSIONS: Our findings demonstrate that separate-acquisition dual-isotope myocardial perfusion SPECT is accurate for coronary artery disease detection, correlates well with rest-stress sestamibi studies for assessment of defect reversibility and results in good to excellent image quality. This approach provides an excellent method for the combined assessment of stress myocardial perfusion and myocardial viability.

Aged↗

Development of the stable isotope tracer approach for studies of copper turnover in the rat and mouse.

The stable isotope tracer approach was explored for long-term investigations of copper turnover in the adult rat and mouse, with inductively coupled plasma mass spectrometry for isotope measurements. The isotopic measurement method permitted precision and accuracy of <1.0%, with an overall sample blank of <0.05 microg copper. Rats were fed a copper-deficient diet and deionized water with (+Cu) or without (-Cu) copper (20 microg/ml). Both groups underwent a single-day replacement of drinking water with 20 microg/ml of (65)Cu. Compared with the baseline isotope ratio ((65)Cu/(63)Cu) of 0.462 +/- 0.002, blood plasma ratios for the +Cu group on days 2, 7, and 14 postdosing were 0.702 +/- 0.021, 0.557 +/- 0.004, and 0.474 +/- 0.001, respectively. The corresponding data for liver were 1.652 +/- 0.018, 0.560 +/- 0.005, and 0.482 +/- 0.001, respectively. For the -Cu group, respective plasma ratios were 1.580 +/- 0.04. 0.917 +/- 0.02, and 0.664 +/- 0.01 for days 2, 7, and 14 postdosing, and the ratios for liver were 0.987 +/- 0.02, 0.876 +/- 0.04, and 0.739 +/- 0.03. Mice previously made copper deficient to varying degrees were given a single-day replacement with the label. When the 24-hour postdosing isotope ratios in the livers of these mice were correlated with the activity of plasma ceruloplasmin, a negative correlation (r = -0.85) was observed. Isotope enrichment in both rats and mice was greater in the copper-deficient animals compared with the controls.

Journal Article↗

Extraction of local hydrogen exchange data from HDX CAD MS measurements by deconvolution of isotopic distributions of fragment ions.

Hydrogen/deuterium exchange (HDX) coupled to protein fragmentation either in solution (by means of proteolysis) or in the gas phase (using collisional activation of protein ions) and followed by mass spectral measurements of deuterium content of individual fragments has become one of the major experimental tools to probe protein structure and dynamics. One difficulty, which often arises in the course of interpretation of HDX MS data, is a need to separate deuterium contribution to the observed isotopic patterns from that of naturally occurring isotopes. Another frequently encountered problem, especially when HDX in solution is followed by protein ion fragmentation in the gas phase, is a need to determine the deuterium content of an internal protein segment based on the measured isotopic distributions of overlapping fragments. While several algorithms were developed in the past several years to address the first problem, the second one did not enjoy as much attention. Here we report a new algorithm based on a maximum entropy principle, which is capable of extracting local exchange data form the isotope distribution of overlapping fragments, as well as subtracting the background due to the presence of natural isotopes and residual deuterium in exchange buffers. The new method is tested with several proteins and appears to generate stable solutions even under unfavorable circumstances, e.g., when the resolving power of a mass analyzer is not sufficient to avoid signal interference or when the isotopic distributions of individual fragments are complex and cannot be approximated with simple binomial distributions. The latter feature makes the algorithm particularly useful when the exchange in solution is correlated or semicorrelated, paving the way to precise structural characterization of non-native protein states in solution.

Algorithms↗

Utilizing gamma isotope tracers to determine sediment source at reef sites near the Charleston Ocean Dredged Material Disposal Site.

The Charleston, South Carolina Ocean Dredged Material Disposal Site (ODMDS) has been heavily utilized as a disposal site for dredged material resulting from maintenance and channel deepening in the Charleston Harbor. Continuous monitoring by the South Carolina Department of Natural Resources at the ODMDS has indicated the presence of fine-grained sediment within the monitoring zones. However, since the Charleston Harbor is formed by the conjunction of three rivers, it has been suggested that some of the fine-grained sediment surrounding the ODMDS could be due to river transport rather than solely by disposal activities. In order to trace the outflow of sediment from the harbor, natural and man-made isotopes were utilized. (7)Be (natural cosmogenic isotope) and (137)Cs (man-made isotope) are often associated with estuarine sediments. Both isotopes were used as tracers in an attempt to determine the extent of density driven sediment flow from the Charleston Harbor. (7)Be was detected in many of the offshore sampling stations indicating a direct correlation to the harbor. (137)Cs was only found in one sediment trap sample offshore, but none the less indicated some transport from the harbor. Further study for utilizing isotopic tracers in determining offshore sediment transport is still being conducted at the disposal site. It is anticipated that further (7)Be and (137)Cs isotopic monitoring offshore Charleston will aid in determining the role that tidal and density driven sediments play in the sediment budgets at the hard bottom reef sites.

Cesium Radioisotopes↗

The effect of exposure to employees from mining and milling operations in a uranium mine on lead isotopes--a pilot study.

Potential exposure during mining and milling of uranium ore has resulted in the industry being highly regulated. Exposure can arise from inhalation of the daughter product radioactive gas radon (222Rn), inhalation of radioactive dust particles from mining and milling, direct irradiation from outside the body, and ingestion of radionuclides (e.g. uranium or radium) in food or water. Making use of the highly unusual lead isotopic signature for uranium ores (high 206Pb/204Pb from the high uranium content, low 208Pb/204Pb from the low Th/U ratio), we undertook a pilot study of nine male mine employees and three controls from the Ranger uranium mine in the Northern Territory Australia to determine if it was feasible to use lead isotopes in blood to identify exposure to uranium-derived materials. The lead isotopic data for the mine employees and controls plot in two distinct fields which are consistent with predicted isotopic patterns. Assuming retention of 10% of the ingested lead, then the increases seen in 206Pb represent intakes of between 0.9 and 15 mg, integrated over the years of exposure. The small amount of lead does not affect blood lead concentrations, but appears to be sufficient to be detectable with sensitive isotopic methods. Further studies, including those on urine, should be undertaken to confirm the veracity of the lead isotope method in monitoring exposure of uranium industry employees.

Adult↗

Effects of high pressure on solvent isotope effects of yeast alcohol dehydrogenase.

The effect of pressure on the capture of a substrate alcohol by yeast alcohol dehydrogenase is biphasic. Solvent isotope effects accompany both phases and are expressed differently at different pressures. These differences allow the extraction of an inverse intrinsic kinetic solvent isotope effect of 1.1 (i.e., (D(2(O)))V/K = 0.9) accompanying hydride transfer and an inverse equilibrium solvent isotope effect of 2.6 (i.e., (D(2(O)))K(s) = 0.4) accompanying the binding of nucleotide, NAD(+). The value of the kinetic effect is consistent with a reactant-state E-NAD(+)-Zn-OH(2) having a fractionation factor of phi approximately 0.5 for the zinc-bound water in conjunction with a transition-state proton exiting a low-barrier hydrogen bond with a fractionation factor between 0.6 and 0.9. The value of the equilibrium effect is consistent with restrictions of torsional motions of multiple hydrogens of the enzyme protein during the conformational change that accompanies the binding of NAD(+). The absence of significant commitments to catalysis accompanying the kinetic solvent isotope effect means that this portion of the proton transfer occurs in the same reactive step as hydride transfer in a concerted chemical mechanism. The success of this analysis suggests that future measurements of solvent isotope effects as a function of pressure, in the presence of moderate commitments to catalysis, may yield precise estimates of intrinsic solvent isotope effects that are not fully expressed on capture at atmospheric pressure.

Alcohol Dehydrogenase↗

Sulphur isotopic investigation of a polluted raised bog and the uptake of pollutant sulphur by Sphagnum.

The sulphur content and sulphur isotopic composition of Sphagnum as well as anionic compositions and sulphur isotope ratios of rainwater inputs and bog waters have been measured at Thorne Moors, a raised bog in eastern England. Rainwater sulphate isotopic composition shows the sulphur input at this site to be dominated by anthropogenic pollution from fossil fuel burning. Strong depletion of sulphate (low SO4(2-)/Cl-) and enrichment in 34S in sulphate occurs at depth in the bog porewaters due to bacterial sulphate reduction. Some surface waters have low SO4(2-)/Cl-) and are 34S enriched due to removal of sulphate by downward diffusion into a sulphate-reducing zone. Other sites have high SO4(2-)/Cl-) which appears to result from oxidation of organically bound sulphur in the peat. Sulphur is present in Sphagnum at around 0.2% by weight and is depleted by 0 to -9 per thousand in the heavier 34S isotope compared to sulphate. Comparison with similar data from pristine coastal sites shows that sulphur incorporation into Sphagnum is enhanced in the polluted site (as Sphagnum sulphur concentrations are higher at lower total sulphur inputs) and that sulphur incorporation is accompanied by a smaller isotopic shift than in the pristine sites. The data support a model of preferential incorporation of partially reduced sulphur species (probably HSO3-) into Sphagnum. In pristine sites these are only available as oxidation products of sulphide formed by sulphate reduction and are 32S depleted. In polluted sites this source is augmented by sulphur(IV) species in atmospheric inputs and the resultant mixture is less depleted in 32S. Thus, in the polluted sites more HSO3- is available for uptake and the isotopic shift between Sphagnum and aqueous sulphur species is smaller.

Journal Article↗

Feathers as a means of monitoring mercury in seabirds: Insights from stable isotope analysis.

Mercury concentrations, together with nitrogen and carbon stable isotope signatures, were determined in body feather samples from northern fulmars Fulmarus glacialis and great skuas Catharacta skua, and in different flight feathers from great skuas. There were no significant relationships between trophic status, as defined using isotope analysis, and mercury concentration in the same feather type, in either species. Mercury concentrations in body feather samples were markedly different between fulmars and skuas, reflecting differences in diet, but there was no corresponding difference in trophic status as measured through nitrogen stable isotope signatures. We conclude that mercury concentrations and stable isotope values in feathers are uncoupled, mercury concentrations apparently reflecting the body pool of accumulated mercury at the time of feather growth whilst stable isotope values reflect the diet at the time of feather growth. There were significant positive correlations between the different flight feathers of great skuas for all three parameters measured. These were strongest between primary 10 and secondary 8, suggesting that these two feathers are replaced at the same time in the moult sequence in great skuas. Stable isotope analysis of different feathers may provide a means of investigating moult patterns in birds.

Journal Article↗

Quantifying peptides in isotopically labeled protease digests by ion mobility/time-of-flight mass spectrometry.

Ion mobility/time-of-flight techniques have been used to analyze mixtures of isotopically labeled peptides. The isotopic labels were generated by treatment of peptides with N-acetoxysuccinimide (or the deuterated analogue), which results in acetylation (or deuterioacetylation) of the primary amines (i.e., the N-terminus and lysine residues). The relative concentrations of a peptide in each sample are determined by comparing the peak intensities for isotopic pairs. An important consideration is that as mixtures become increasingly complex, isotopic pairs of peaks may overlap with other peaks in the mass spectrum. The influence of the acetyl and deuterioacetyl groups on the mobilities of peptides is considered. The coincidence in mobilities of isotopic pairs provides a means of distinguishing isotopic pairs from other isobaric interferences.

Acetylation↗

Conversion of carbon into CF4 for SI-traceable measurements of absolute carbon isotope amount ratios: a feasibility study.

The feasibility of performing SI-traceable carbon isotope amount ratio measurements following conversion of carbon into CF4 was studied. A procedure for the direct fluorination of carbon with elemental fluorine was developed, and the conversion step was checked for losses, blank contributions, and the absence of systematic isotope effects. Gas chromatography was used to identify and quantify the gaseous fluorination products and to isolate CF4 from byproducts. After fluorination of graphite carbon, CF4 and perfluoroalkanes with up to six carbon atoms were observed as reaction products. Within an uncertainty of 10%, the graphite carbon was fully recovered in the gaseous carbon fluorides, with the main product being CF4 (80-90%) and C2F6 as the major byproduct. The fluorination and GC procedures were found to introduce an alteration not bigger than 0.03 +/- 0.04/1000 on the isotopic composition of CF4. Carbon blank contributions introduced during the fluorination procedure were below 0.5% relative to a typical sample of 4 mg of carbon. For two of the materials investigated, the carbon isotope ratios measured on a differential mass spectrometer were reproducible within a standard deviation of approximately 0.1/1000 for several individual fluorinations. For these materials, the developed fluorination procedure is a straightforward process, which can be used as a foundation to establish SI-traceable measurements of carbon isotope amount ratios. However, for the third graphite material the formation of byproducts (C2F6-C6F14) was found to induce significant isotopic fractionation.

Journal Article↗

Compound-specific carbon isotope analysis of volatile organic compounds in the low-microgram per liter range.

Compound-specific carbon isotope analysis (CSIA) has become an important tool in biological, archeological, and geological studies as well as in forensics, food sciences, and organic chemistry. If sensitivity could be enhanced, CSIA would further have an improved potential for environmental applications such as, for example, in situ remediation studies to assess contaminated environments, identification of pollutant degradation pathways and kinetics, distinction between degradation/formation mechanisms, or, verification of contaminant sources. With this goal in mind, we have developed methods to determine delta13C values of commonly reported groundwater contaminants in low-microgram per liter concentrations. Several injection and preconcentration techniques were evaluated for this purpose, i.e., on-column injection, split/ splitless injection, solid-phase microextraction (SPME), and purge and trap (P&T) in combination with gas chromatography-isotope ratio mass spectrometry. The delta13C values of the target compounds were determined by liquid injections of the analytes dissolved in diethyl ether or, in the case of P&T and SPME, by extraction from water spiked with the analytes. P&T extraction was the most efficient preconcentration technique reaching method detection limits (MDLs) from 0.25 to 5.0 microg/L. These are the lowest MDLs reported so far for continuous-flow isotope ratio determinations, using a commercially available and fully automated system. Isotopic fractionation resulting from preconcentration and injection was investigated and quantified for the priority groundwater pollutants methyl tert-butyl ether (MTBE), chloroform, tetrachloromethane, chlorinated ethylenes, benzene, and toluene. The isotopic fractionations caused by the extraction techniques were small but highly reproducible and could therefore be corrected for. P&T was characterized by a higher reproducibility and smaller isotopic fractionations than SPME. Among the liquid injection techniques, cold on-column injection resulted in slightly better precision compared to split/splitless injection. However, the MDLs determined for liquid injections were 4-6 orders of magnitude higher (i.e., 9.5-2800 mg/L) than for P&T and SPME. Since both of the latter methods are solventless, a better chromatographic resolution was obtained than for the liquid injection techniques. The P&T and SPME methods described here are also applicable for CSIA of D/H ratios, which require 10-20 times higher analyte concentrations than 13C/12C analysis. Finally, the applicability of the described methods is demonstrated for pollutant concentrations of only 5-60 microg/L in environmental samples.

Journal Article↗

Chemical conversion of nitrate and nitrite to nitrous oxide for nitrogen and oxygen isotopic analysis in freshwater and seawater.

We present a novel method for nitrogen and oxygen natural isotopic abundance analysis of nitrate and nitrite of seawater and freshwater at environmental concentrations. The method involves the reduction of nitrate to nitrite using spongy cadmium with further reduction to nitrous oxide using sodium azide in an acetic acid buffer. For separate nitrite analysis, the cadmium reduction step is simply bypassed. Nitrous oxide is purged from the water sample and trapped cryogenically using an automated system with subsequent release into a gas chromatography column. The isolated nitrous oxide is then analyzed on a continuous flow isotope ratio mass spectrometer via an open split. This paper describes the basic protocol and reaction conditions required to obtain reproducible natural abundance level nitrogen and oxygen isotopic ratios from nitrate, nitrite, or both, and the results obtained to support these conclusions. A standard deviation less than 0.2 per thousand for nitrogen and 0.5 per thousand for oxygen was found for nitrate samples ranging in concentration from 40 to 0.5 microM (better for nitrite), with a blank of 2 nmol for 50-mL samples. Nitrogen and oxygen isotopic fractionation and oxygen atom exchange were consistent within each batch of analysis. There was no interference from any seawater matrixes. Only one other method published to date can measure the nitrate oxygen isotopic abundance in seawater and none that do so for nitrite alone in the presence of nitrate. This method may prove to be simpler, faster, and obtain isotopic information for lower concentrations of nitrate and nitrite than other methods.

Journal Article↗

High precision measurements of non-mass-dependent effects in nickel isotopes in meteoritic metal via multicollector ICPMS.

We measured the Ni isotopic composition of metal from a variety of meteorite groups to search for variations in the 60Ni abundance from the decay of the short-lived nuclide 60Fe (t(1/2) = 1.49 My) and for possible nucleosynthetic effects in the other stable isotopes of Ni. We developed a high-yield Ni separation procedure based on a combination of anion and cation exchange chromatography. Nickel isotopes were measured on a single-focusing, multicollector, inductively coupled mass spectrometer (MC-ICPMS). The external precision on the mass-bias-corrected 60Ni/58Ni ratio (+/-0.15 epsilon; 2sigma) is comparable to similar studies using double-focusing MC-ICPMS. We report the first high-precision data for 64Ni, the least abundant Ni isotope, obtained via MC-ICPMS. The external precision on the mass-bias-corrected 64Ni/58Ni ratio (+/-1.5 epsilon; 2sigma) is better than previous studies using thermal ionization mass spectrometry. No resolvable excesses relative to a terrestrial standard in the mass-bias-corrected 60Ni/58Ni ratio were detected in any meteoritic metal samples. However, resolvable deficits in this ratio were measured in the metal from several unequilibrated chondrites, implying a 60Fe/56Fe ratio of approximately 1 x 10(-6) at the time of Fe/Ni fractionation in chondritic metal. A 60Fe/56Fe ratio of (4.6 +/- 3.3) x 10(-7) is inferred at the time of Fe/Ni fractionation on the parent bodies of magmatic iron meteorites and pallasites. No clearly resolvable non-mass-dependent anomalies were detected in the other stable isotopes of Ni in the samples investigated here, indicating that the Ni isotopic composition in the early solar system was homogeneous (at least at the level of precision reported here) at the time of meteoritic metal formation.

Journal Article↗

Mycobacterium tuberculosis mycothione reductase: pH dependence of the kinetic parameters and kinetic isotope effects.

The recent identification of the enzyme in Mycobacterium tuberculosis that catalyzes the NADPH-dependent reduction of the unique low molecular weight disulfide mycothione, mycothione reductase, has led us to examine the mechanism of catalysis in greater detail. The pH dependence of the kinetic parameters V and V/K for NADPH, NADH, and an active analogue of mycothione disulfide, des-myo-inositol mycothione disulfide, has been determined. An analysis of the pH profiles has allowed the tentative assignment of catalytically significant residues crucial to the mechanism of disulfide reduction, namely, the His444-Glu449 ion pair and Cys39. Solvent kinetic isotope effects were observed on V and V/K(DIMSSM), yielding values of 1.7 +/- 0.2 and 1.4 +/- 0.2, respectively, but not on V/K(NADPH). Proton inventory studies (V versus mole fraction of D(2)O) were linear, indicative of a single proton transfer in a solvent isotopically sensitive step. Steady-state primary deuterium kinetic isotope effects on V have been determined using NADPH and NADH, yielding values of 1.27 +/- 0.03 and 1.66 +/- 0.14, respectively. The pre-steady-state primary deuterium kinetic isotope effect on enzyme reduction has values of 1.82 +/- 0.04 and 1.59 +/- 0.06 for NADPH and NADH, respectively. The steady-state primary deuterium kinetic isotope effect using NADH coincide with that obtained under single turnover conditions, suggesting the complete expression of the intrinsic primary kinetic isotope effect. Rapid reaction studies on the reductive half-reaction using NADPH and NADH yielded maximal rates of 129 +/- 2 and 20 +/- 1 s(-1), respectively, while similar studies of the oxidation of the two-electron reduced enzyme by mycothiol disulfide yielded a maximum rate of 190 +/- 10 s(-1). These data suggest a unique flavoprotein disulfide mechanism in which the rate of the oxidative half-reaction is slightly faster than the rate of the reductive half-reaction.

Deuterium↗