Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Computer Terminals”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Verifying keyed medical research data.

Although diminished use of double keying for the verification of keyed medical research data has occurred, there are no published data that demonstrate the existence of equivalent or better replacement. The simple replacement of double keying with visual comparison is not recommended because visual comparison is too susceptible to the transient energy levels of the individual who makes the comparison. Some system design innovations applicable in specific situations allow elimination of verification by providing nearly equivalent or possibly even superior data quality assurance opportunities. These alternatives include designs where one replaces the transcription to data forms by direct keying from original source documents coupled with extensive quality reviews, and designs with direct data base input of data subjected to intense automated consistency checking and immediate analytic use. In both cases, the absence of keyed data verification places a greater burden for data quality assurance on other subsystems, such as quality review, and ultimately the analytic process. Data entry systems based on new technologies, such as tablet computers, electronic image processing, and voice input, will require similar considerations for assuring data quality.

Clinical Trials as Topic↗

Characterization of five novel human genes in the 11q13-q22 region.

The redundancy of sequences in dbEST has approached a level where contiguous cDNA sequences of genes can be assembled, without the need to physically handle the clones from which the ESTs are derived. This is termed EST based in silico gene cloning. With the availability of sequence chromatogram files for a subset of ESTs, the quality of EST sequences can be ascertained accurately and used in contig assembly. In this report, we performed a study using this approach and isolated five novel human genes, C11orf1-C11orf5, in the 11q13-q22 region. The full open reading frames of these genes were determined by comparison with their orthologs, of which four mouse orthologs were isolated (c11orf1, c11orf2, c11orf3 and c11orf5). These genes were then analyzed using several proteomics tools. Both C11orf1 and C11orf2 are nuclear proteins with no other distinguishing features. C11orf3 is a cytoplasmic protein containing an ATP/GTP binding site, a signal peptide located in the N-terminus and a similarity to the C. elegans protein "Probable ARP 2/3 complex 20kD subunit." C11orf4 is a peptide which displays four putative transmembrane domains and is predicted to have a cytoplasmic localization. It contains signal peptides at the N- and C-termini. C11orf5 is a putative nuclear protein displaying a central coiled coil domain. Here, we propose that this purely EST-based cloning approach can be used by modestly sized laboratories to rapidly and accurately characterize and map a significant number of human genes without the need of further sequencing.

Animals↗

Work stress in Japanese computer engineers: effects of computer work or bioeducational factors.

To examine whether computer work and bioeducational factors (age and school career) have significant effects on work stress in computer engineers in Japan, we administered a stress questionnaire to 764 male computer engineers and 211 male office workers in a computer-manufacturing factory in Tokyo. Four scales of perceived psychological stress at work examined were work overload, poor human relationships at work, unsuitable job, and competition-dismissal anxiety. The results of the three-way analysis of variance, in which age (20-29, 30-39, and 40-49 years), school career (high school and university graduates), and computer work (computer engineers and office workers) were three variation factors, indicated that: (1) there were no significant differences in all scores of work stress between computer engineers and office workers (P > 0.05); (2) scores for unsuitable job and poor human relationships at work were significantly higher in high school graduates than in university graduates (P < 0.05); and (3) there were significant age differences in scores for three scales of work stress (unsuitable job, competition-dismissal anxiety, and work overload: P < 0.001, P < 0.01, and P < 0.05, respectively). These findings suggest that computer work has no significant effect on perceived work stress in computer engineers; on the other hand, age and school career do have effects.

Adult↗

A small reservoir of disabled ORFs in the yeast genome and its implications for the dynamics of proteome evolution.

We surveyed the sequenced Saccharomyces cerevisiae genome (strain S288C) comprehensively for open reading frames (ORFs) that could encode full-length proteins but contain obvious mid-sequence disablements (frameshifts or premature stop codons). These pseudogenic features are termed disabled ORFs (dORFs). Using homology to annotated yeast ORFs and non-yeast proteins plus a simple region extension procedure, we have found 183 dORFs. Combined with the 38 existing annotations for potential dORFs, we have a total pool of up to 221 dORFs, corresponding to less than approximately 3% of the proteome. Additionally, we found 20 pairs of annotated ORFs for yeast that could be merged into a single ORF (termed a mORF) by read-through of the intervening stop codon, and may comprise a complete ORF in other yeast strains. Focussing on a core pool of 98 dORFs with a verifying protein homology, we find that most dORFs are substantially decayed, with approximately 90% having two or more disablements, and approximately 60% having four or more. dORFs are much more yeast-proteome specific than live yeast genes (having about half the chance that they are related to a non-yeast protein). They show a dramatically increased density at the telomeres of chromosomes, relative to genes. A microarray study shows that some dORFs are expressed even though they carry multiple disablements, and thus may be more resistant to nonsense-mediated decay. Many of the dORFs may be involved in responding to environmental stresses, as the largest functional groups include growth inhibition, flocculation, and the SRP/TIP1 family. Our results have important implications for proteome evolution. The characteristics of the dORF population suggest the sorts of genes that are likely to fall in and out of usage (and vary in copy number) in a strain-specific way and highlight the role of subtelomeric regions in engendering this diversity. Our results also have important implications for the effects of the [PSI+] prion. The dORFs disabled by only a single stop and the mORFs (together totalling 35) provide an estimate for the extent of the sequence population that can be resurrected readily through the demonstrated ability of the [PSI+] prion to cause nonsense-codon read-through. Also, the dORFs and mORFs that we find have properties (e.g. growth inhibition, flocculation, vanadate resistance, stress response) that are potentially related to the ability of [PSI+] to engender substantial phenotypic variation in yeast strains under different environmental conditions. (See genecensus.org/pseudogene for further information.)

Chromosomes, Fungal↗

A molecular framework for the phylogeny of the ant subfamily dolichoderinae.

Partial sequences are reported for the mitochondrial genes for cytochrome oxidase subunits 2 and 3 and for cytochrome b, and the entire sequence of the gene for tRNA(Leu)(UUR) for species from 14 genera of dolichoderine ants and from three outgroup genera. Considerable variation was observed between tRNA genes in the size of the TPsiC arm and the DHU and anticodon loops and whether or not the TPsiC stem possesses a GC pair. The outgroup taxa showed complete TAA CO1 stop codons, but dolichoderines have either TA or T. The outgroup taxa showed a noncoding gap between the CO1 and the tRNA(Leu)(UUR) genes. A phylogeny-independent compatibility test using the amino acid sequences showed differences between the genes consistent with variation in evolutionary rates, according with other studies. Base compositions proved heterogeneous between species, hence phylogenetic analysis was restricted to the protein sequences using maximum likelihood and the mtREV24 replacement matrix. A maximum-likelihood consensus tree has similarities to those from morphological studies with some exceptions such Leptomyrmex falling within the dolichoderine genera rather than basally, and the accretion of genera formerly included under Iridomyrmex. Features of the tRNA genes and the CO1 termination codons agree quite well with the molecular phylogeny.

Animals↗

Does work with visual display units impair visual activities after work?

It is well established that visual display unit (VDU) operators complain of visual fatigue and visual stress during after-work hours. The present study was divided into two parts. In the first part, standard eye examinations were performed on a group of VDU workers (n = 32) and a control group (n = 15); those subjects who were found to have correct vision (n = 16 and 13, respectively) participated in the second part. The eye examinations revealed that on the average, the VDU workers suffered more than twice as many visual impairments as the controls. In those with correct vision, the near point of accommodation was measured at the beginning of the workday at the start of the week, and at the end of the workday, four days later. In the VDU group, the decrease in accommodation was uniformally distributed between zero and 1.0 diopter, whereas among the non-VDU workers, 77% of the decrease was between zero and 0.25 diopter. The dynamic range of accommodation in the VDU workers on the second examination was smaller than on the first. We conclude that some of the visual stress and visual fatigue that developed at work hindered visual activities after work.

Accommodation, Ocular↗

Theta rhythms: state of consciousness.

The role of midline frontal theta in human is discussed, with reference to its relation on consciousness. Clinical observations of the appearance of this theta activity under various conditions are reviewed. These include simulated diving, brain tumour, chemical intoxication, exercise, mental calculation, sleep and medication. The mechanism of generation of this frontal midline theta activity is discussed.

Adolescent↗

A computer and video display based system for training eccentric viewing in macular degeneration with an absolute central scotoma.

A new approach designed to establish the most suitable area for eccentric viewing and to teach and train patients with severe age-related macular degeneration (AMD) to use the eccentric viewing technique is described. Using a computer and video display based system, as well as software written specifically for this purpose, we investigated and trained ten consecutive patients with AMD. The patients were 80.1 + or - 5.6 years old, on average. All of them had an absolute central scotoma. Mean visual acuity was 0.035 + or - 0.016. After 30 min of testing, instruction and reading on the screen, followed by 2.6 + or - 0.69 one-hour training sessions, on average, with the low vision therapist, reading newspaper and book texts with the aid of hyperoculars or aplanatic systems and a very short reading distance, the patients achieved a reading speed of 58.9 + or - 19.7 words/min, significantly (p<0.001) higher than the initial speed when reading on the screen, 11.5 + or - 4.5 words/min.

Aged↗

Identification of the preferential gaze position through elevation of visual fatigue in a selected group of VDU operators. A preliminary study.

A selected group of VDU workers were tested in an attempt to achieve objective evidence of visual fatigue and to identify a preferential monitor/gaze position during a particular work setting. Each subject was scored in a two-phase test. The highest mean scores were achieved when the monitor was lowered with respect to the primary/gaze position; the scores obtained with the monitor in primary or upward gaze position were significantly lower (p < 0.001). The downward gaze position should be considered more comfortable for both innervational and anatomical factors, as stated in previous studies of ocular mobility. A reduction of vertical saccades could also play a role in lessening visual fatigue in this gaze position.

Adult↗

Computed radiography in neonatal and pediatric intensive care units: a comparison of 2.5 K x 2 K soft-copy images vs digital hard-copy film.

OBJECTIVE: The goal of the study was to determine whether soft-copy images on high-resolution monitors (2.5 K x 2 K) are suitable for primary interpretation of images from pediatric and neonatal intensive care units. The hypotheses were that hard and soft images yield similar diagnostic information, and that both residents and faculty radiologists can use monitors effectively. Previous reports have produced conflicting results; the need for larger sample sizes has been emphasized. MATERIALS AND METHODS: One thousand one hundred and four images produced by computed radiography using the Kodak Ectascan Imagelink system were prospectively analyzed by two pediatric radiologists, one reading hard copy and the other soft copy of the same images. Bias was controlled by equal distribution of modalities between observers and by daily alternation of modality. Hard- and soft-copy observations of presence or absence of nine specific tubes and nine specific diagnostic findings were compared. Interobserver differences between pediatric radiologists and radiology residents were studied on additional images. The kappa statistic was used to evaluate the level of agreement for all observations. RESULTS: There was excellent agreement between hard and soft copy interpretation for each tube and diagnostic finding (kappa values 0.93-1.0) and excellent interobserver agreement between two pediatric radiologists (kappa values 0.84-1.0). The level of agreement between radiology residents and pediatric radiologist was excellent for the most objective findings. All results were statistically significant (p < 0.001). CONCLUSION: High resolution soft-copy images are suitable for primary interpretation in patients in pediatric and neonatal intensive care units.

Child↗

Evaluation of grey-scale standard display function as a calibration tool for diagnostic liquid crystal display monitors using psychophysical analysis.

The digital imaging and communications in medicine (DICOM) standard proposed the grey-scale standard display function (GSDF) as a calibration tool for making the gradation characteristic of a radiographic output image consistent. This is designed in such a manner that the contrast visually recognised by observers (called psychophysical contrast) becomes a constant for all digital driving levels. The DICOM standard calls such an ideal characteristic perceptual linearisation. The psychophysical gradient that can express the psychophysical contrast was introduced for the evaluation of the GSDF using a liquid crystal display monitor. Investigations regarding its ability to yield a constant psychophysical contrast, independent of the digital driving level change and under an actual observation environment, such as for clinical radiographic diagnosis in hospital, were carried out. The psychophysical gradients of the GSDF were obtained for two kinds of observation environment: one was a restricted environment such as in a dark room, under steady-state adaptation, using the sinusoidal grading pattern corresponding to the peak frequency of the human eye response. The other was an actual environment reflecting that encountered during clinical diagnosis in a hospital. As a result, the psychophysical gradient under the restricted environment became almost constant and independent of the change in digital driving level, i.e. perceptual linearisation could be satisfied. Furthermore, under the actual observation environment, the psychophysical gradient decreased gradually with the increase in digital driving level, i.e. the perceptual linearisation could not be satisfied. The percentage decrease in the value of the psychophysical gradient at the maximum luminance area was approximately 60% compared with that at the minimum luminance area. Accordingly, the GSDF is unsuitable as a calibration tool for the liquid crystal display monitor, which will be used in actual clinical diagnosis, as it cannot achieve 'perceptual linearisation' under the actual environment. For the purpose of clinical diagnosis, it is necessary to enlarge the physical gradient of GSDF further in the high digital driving level range (which relates to a high luminance area) to give an approximation that is as close to the idealised form as possible.

Calibration↗

Blinks as an index of cognitive activity during reading.

Horizontal and vertical EOG recordings of eye movements were analyzed to determine the spatial and temporal distribution of blinks and the patterns of eye movements (saccades and fixation pauses) exhibited by six subjects during the reading of stories presented in two formats (on paper and on a VDT). The frequency and placement of blinks was not affected by the presentation condition. Blinks were determined to be non-randomly distributed during reading. Significantly more blinks (36%) occurred in conjunction with saccades than the proportion of time consumed by saccades (12%) would predict. Significantly more blinks (36%) occurred in the vicinity of line change saccades, which accounts for 15% of reading time, and with fixation pauses associated with regressions (42%), which accounts for 26% of reading time, than with fixation pauses during normal reading (22%), which accounts for 60% of reading time. The results of the study suggest that blink behavior during reading is under perceptual and cognitive control.

Adult↗

Video-enhanced visualization of the larynx and intubation with the Bullard laryngoscope--equipment report.

PURPOSE: A simple technical solution is presented to provide video transmission from the tip of a Bullard laryngoscope to a bedside video display, while the operator is still able to look through the viewing ocular of the Bullard laryngoscope during tracheal intubation. EQUIPMENT: This is achieved by insertion of an ultrathin fibreoptic video-endoscopic system into the working channel of the Bullard laryngoscope. Thereby the view from the distal blade tip is transmitted to a bedside monitor, without interfering with the use of the Bullards laryngoscope's original eyepiece. The presented technical solution allows video transmission without considerable additional weight normally associated with attaching video endoscopy cameras, light and camera cables to endoscopic devices. Thus, the Bullard laryngoscope remains lightweight and easy to maneuver. A screw-threaded adapter with a side-port is proposed to prevent displacement of the fibreoptic cable while still allowing application of oxygen. CONCLUSION: Experience and skills with tracheal intubation using the presented video-enhanced Bullard laryngoscope can be achieved in the originally intended way, while the supervisor or attending viewers can follow the tracheal intubation procedure on the video display.

Computer Terminals↗

Active matrix liquid crystal displays for clinical imaging: comparison with cathode ray tube displays.

Fifteen large-area, flat-panel displays used for clinical image review were evaluated for image quality and compared with 30 comparably sized cathode ray tube (CRT) monitors. Measurements were of image display patterns by Video Electronic Standards Association (VESA) and a commercial product. Field measurements were made of: maximum and minimum luminance, ambient lighting, characteristic curve (gamma), point shape and size, high-contrast resolution, uniformity, and distortion. Assessments were made of pixel defects, latent image patterns, ghosting artifacts, and viewing angle luminance. Also, a questionnaire was generated for users of the flat-panel and CRT units. Seventeen respondents indicated no preference for either flat panel or CRT. Results show these flat panels to have higher luminance (mean, 177.7 cd/m2); larger number of just noticeable differences (JNDs; n = 555), higher gamma, comparable uniformity, and warm-up time. CRTs had less angle viewing dependence and far fewer artifacts (ghosting and latent images). Our questionnaire showed active matrix liquid crystal displays (AMLCD) to be fully acceptable for clinical image viewing. Furthermore, the statistical results show that further testing for new AMLCDs of this type is unwarranted.

Computer Terminals↗

Contrast-detail characteristic evaluations of several display devices.

The contrast-detail characteristic of a display system is a powerful tool for evaluating displayed image quality. It takes into account the physical properties of the display, the psychophysical aspects of the observer, and the viewing conditions. It is a more sensitive measurement of the displayed image quality than a simple Society of Motion Picture and Television (SMPTE) pattern. Yet, it is relatively simple to measure and requires no special equipment or analysis tools. In this presentation, the results of the evaluation of several cathode ray tube (CRT) monitors and a digital projector will be presented. Contrast-detail characteristics of these display devices were measured under various gamma and display settings. The results show excellent intraobserver and interobserver variance (<1 step on the grayscale). Extraneous light, such as room lighting, affects the contrast threshold more severely at low background levels more than at high background. Gamma settings on graphics adapters affect the shapes of the contrast-detail curve for all display types. Gamma settings of approximately 2.0 result in a better contrast threshold for both high and low background brightness. The results show complex differences in contrast-detail characteristics for different display types. The digital projector display not only has significantly worse performance than CRT monitors, but also is affected more by extraneous light. High-brightness monitors with optimal monitor and graphics adapter settings have better performance than color or low-brightness monitors. However, under some settings, the performance of high-brightness monitors is not always better at all object sizes and background levels.

Computer Terminals↗

Picture archiving and communication system in Hokkaido University Hospital: advantage and disadvantage of HU-PACS chest roentgenogram images in the outpatient clinic.

A new Hokkaido University picture archiving and communication system (HU-PACS) has been in clinical use in the outpatient clinic at HU Hospital. To evaluate the quality of the cathode-ray tube (CRT) monitor images, we compared the detectability of line shadows in the chest roentgenogram images on the CRT monitor with those on the computed radiography (CR) film. We randomized chest roentgenograms from 20 patients who were admitted to the outpatient clinic with pulmonary disease. Two physicians, whose speciality is chest roentgenogram diagnosis, checked whether they could recognize a horizontal fissure line (hairline) on the posteroanterior view and a minor fissure line and major fissure lines on the lateral view. Only 30% of hairlines were recognized on CRT monitor as compared with 65% on CR film. On the lateral view, only 68% of major fissures and 53% of minor fissures on CRT monitor were recognized as compared with 89% and 79%, respective on CR film. Furthermore, it was somewhat difficult to follow entire lines on some of the CRT monitor images. Clinically, the greatest advantage of the PACS is immediate availability of images, including chest roentgenogram, chest computed tomography (CT) and magnetic resonance imaging (MRI). PACS is also convenient for consulting colleagues in other departments. Unfortunately, the quality of the image on the CRT monitor is not yet good enough to visualize line shadows and small solitary lesions on the chest roentgenogram image. Recent advances in high technology have been so rapid, however, that higher resolution CRT monitors will be available soon.

Computer Terminals↗