Second national external quality assessment scheme in hematology: the Philippine experience.

The Philippine Council for Quality Assurance In Clinical Laboratories has conducted two National External Quality Assessment Schemes (NEQAS) in Hematology. The first survey was conducted in December 1999 and the second in August 2000, with 95 and 187 laboratories, using mostly automated analyzers, participating respectively. Control materials were distributed during a two-week period by human network, and analyzed over a six to eight week period. For the first survey, only 36 laboratories (38.0%) submitted results. Data was divided into 4 peer groups based on the manufacturer. Since most of the samples were hemolysed upon analysis, only WBC and HGB parameters were evaluated. No outliers were detected in each peer group after analysis by the 'Peer Group Mean and SDI' method. Using the clinical laboratory improvement act of 1988 proficiency testing criteria (CLIA'88), only 5 results (13.9%) were unsatisfactory for WBC, and all results were satisfactory for HGB. For the second survey, 87 laboratories (47%) responded. Data was divided into 5 peer groups. There were few incidents of sample deterioration. Although majority of the coefficient of variations were acceptable, about 23 (12.6%) participants showed abnormality in at least one parameter after analysis by the 'Peer Group Mean and SDI'. Using CLIA'88, 5 WBC (6.5%), 6 RBC (7.6%), 8 HGB (9.7%), 15 HCT (19.0%), and 7 PLT (8.0%) results were unsatisfactory. In summary, the first NEQAS study served as a pilot study. Valuable lessons were learned for the improvement of the second NEQAS. The second NEQAS study was marked by a much larger sample size and better results.

Hematologic Tests↗

[The use of biochemical blood indices for the laboratory diagnosis of internal diseases using the automated complex device-computer].

Application of biochemical parameters of blood, reflecting disturbances in lipid, protein, carbohydrate, pigment and water-saline metabolism for diagnostics for internal organs diseases is discussed. Methods of clinical biochemistry in combination with subsequent automatic processing of the data obtained on the basis of probability theory and mathematical statistics methods can be used for preliminary computer diagnosis and further examination of a patient, as well as for construction of specific complexes of symptoms for some diseases. Due to their mobility, the preliminary computer diagnostics data can be successfully applied to different pathologies and groups of population.

Blood Chemical Analysis↗

Application and flexibility of robotics in automating extraction methods for food samples.

Laboratory robotic technology has made it possible to automate the manually intensive operations associated with the extraction of vitamins from food. The modular approach to robotics allows the conversion from one extraction procedure to another by a simple addition or replacement of a module plus reprogramming. This is illustrated for the extraction of vitamins C and B1 from food samples. Because many of the organic micronutrients are unstable, storage and extraction conditions must be established to stabilize labile compounds if the full capabilities of robotics are to be realized.

Animals↗

Problems with the estimation of urine protein by automated assays.

OBJECTIVES: Most clinical laboratories replaced their manual precipitation techniques for the determination of urinary protein with automated dye binding assays or benzethonium chloride-turbidimetric assays. Few studies have validated these assays for the measurement of urinary proteins in the normal range. DESIGN AND METHODS: This study compares four automated assays for the measurement of urinary protein to a manual Ponceau S/TCA precipitation assay. We evaluated the linearity, the precision, the analytical sensitivity, the accuracy and the recovery of different proteins for each assay. RESULTS: All assays showed good linearity with the theoretical concentration of albumin present in the sample. The coefficient of variation was below 10% at a concentration of 0.142 g/L. However, the manual Ponceau S/TCA assay demonstrated superior analytical sensitivity. Accuracy determinations showed a variable positive bias and poor correlations at concentrations below 0.1 g/L when compared to the Ponceau S/TCA assay. Small molecular weight peptides particularly affected the pyrogallol red assays but other urinary components also interfered with the automated assays. CONCLUSIONS: Most automated assays show high imprecision and poor accuracy for the measurement of urinary protein in the normal range. The Ponceau S/TCA offers a precise and accurate manual alternative to these automated assays.

Albuminuria↗

The computerisation of scientific services.

A full computerised laboratory information management system has been developed in the Department of Scientific Services. The system manages the acquisition and flow of laboratory data. A novel automated reporting procedure has been developed to generate customised laboratory reports. Based on the workload values of laboratory tests, the system integrates the laboratory data with management information to provide rapid and reliable productivity measurement and cost and pricing computations.

Clinical Laboratory Information Systems↗

Evaluation of the PAPNET system in a general pathology service.

OBJECTIVE: To compare the results of an automated rescreening device (PAPNET) with manual screening of Papanicolaou (Pap) smears. DESIGN: All normal or technically unsatisfactory smears and a random sample of abnormal smears on manual screening were submitted for PAPNET rescreening. SETTING: Large general pathology laboratory in Sydney between January and September 1995. RESULTS: Of 54,658 PAP smears classified on manual screening as normal 266 were reclassified as abnormal after PAPNET screening (32 atypical squamous cells of uncertain significance, 217 low-grade squamous intraepithelial lesions and 17 high-grade intraepithelial lesions). Of the random sample of 1022 smears classified on manual screening as abnormal, all high-grade intraepithelial lesions (122 smears) and squamous cell carcinomas (2 smears) were also detected by PAPNET, and 112 were reclassified as normal by PAPNET (14 atypical squamous cells of uncertain significance and 98 low-grade squamous intraepithelial lesions). Histological follow-up confirmed 15 of the 17 smears classified as high-grade intraepithelial lesions on PAPNET screening and detected a further seven that had been classified by PAPNET as either atypical squamous cells of uncertain significance or low-grade squamous intraepithelial lesions. CONCLUSIONS: When used as a quality-control measure in a general pathology laboratory, the PAPNET automated screening system detects higher numbers of abnormal PAP smears than manual screening.

Australia↗

Automation of a fluorescence-based multiplex PCR for the laboratory confirmation of common bacterial pathogens.

A fluorescence-based multiplex PCR was automated for the simultaneous detection of Neisseria meningitidis, Streptococcus pneumoniae and Haemophilus influenzae in clinical samples from patients with suspected meningitis. Sensitivity of one to two genome copies per 100 microl sample and specificity of 100% for each organism were shown. Automation of DNA extraction, liquid handling, PCR and analysis are achieved on a single platform, which enables a high throughput and rapid turnaround of clinical samples that, in turn, leads to faster diagnosis. This is ultimately beneficial to the treatment of the patient and for public health management.

Adolescent↗

Evaluation of clinical chemistry laboratory performance in twenty Veterans Administration hospitals.

Twenty highly automated Veterans Administration (VA) Hospital laboratories participated in a study to evaluate their performances of routine chemistry tests. Ten of the laboratories had been identified as "superior" on the basis of previous College of American Pathologists Surveys. Several aspects of proficiency surveys were simultaneously examined: use of masked vs. unmasked survey specimens, methods of ranking, and comparison of medically useful performance criteria. The laboratories were found in general to be performing at the level of the state of the art and, more importantly, realistically meeting the criteria for medical needs for most routine tests. There was no difference between results obtained with masked and unmasked specimens. The ten "superior" laboratories showed slightly greater precision than the others, but were not more accurate, and two of them performed very poorly in the present study. The sum of squared SDI's was found to be a helpful technic for ranking and identifying outstanding and poor performances.

Blood Chemical Analysis↗

Laboratory evaluation of the Sysmex SE-9500 automated haematology analyser.

The Sysmex SE-9c500 is a new, fully automated haematology analyser, providing a complete blood count (CBC), including a five-part differential count (DC), with flagging of morphological abnormalities. The SE-9500 was evaluated according to guidelines published by the International Committee for Standardisation in Haematology (ICSH). The results demonstrated minimal carryover (< 0.01%) and excellent linearity for WBC, RBC, HGB and platelet (PLT) (r > 0.995). Samples were stable with regard to CBC parameters after storage for up to 48 h at room temperature (RT) and 4 degrees C. Imprecision was generally acceptable for all CBC parameters (CV < 5%). Correlation between the SE-9500 and reference methods was excellent (r > 0.97) for all the major CBC parameters (WBC, RBC, HGB, PLT). There was minimal interference for WBC, RBC, HGB and PLT at high concentrations of bilirubin (BIL=224 micromol/l) or triglyceride (TG=7.78 mmol/l). SE-9500 reference values for CBC parameters are presented. Our results indicate that the SE-9500 is an excellent tool for routine haematological examination.

Adult↗