Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “surface modification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Influence of a new surface modification of intraocular lenses with fluoroalkylsilan on the adherence of endophthalmitis-causing bacteria in vitro.

INTRODUCTION: Dynasilan is a fluoroalkylsilan that is able to interact with surface active centres on intraocular lenses (IOL), offering a new way for surface modification of different IOL materials. The purpose of this in vitro study was to investigate the influence of this new surface modification on the adherence of two typical endophthalmitis causing bacteria (Staphylococcus epidermidis, Propionibacterium acnes). MATERIALS AND METHODS: In a pilot experiment, the effect of Dynasilan coating on the adherence of S. epidermidis was tested on glass slides. Forty-two Dynasilan-modified and 42 unmodified IOL (14 PMMA, 14 silicone and 14 hydrogel) were incubated at 37 degrees C in brain heart infusion broth (10(8) CFU/ml) with either S. epidermidis for 24 h or with P. acnes for 1 h. Subsequently, the adherent bacteria were resuspended using ultrasonification at 35 kHz for 3x45 s. After dilution series and incubation at 37 degrees C on Petri dishes for 24 h and 3 days, respectively, the colonies were counted. RESULTS: In the pilot experiment, a markedly lower number of adherent S. epidermidis was observed on Dynasilan-modified glass slides. Of all IOL materials incubated with S. epidermidis, those modified with Dynasilan showed a lower mean number of adherent bacteria (mean 1.37x10(7); SD 2.37x10(7)) than those untreated (2.43x10(7); SD 3.04x10(7)). IOLs incubated with P. acnes showed a significantly lower mean number of adherent bacteria of 2.51x10(4) (SD 2.71x10(4)) on Dynasilan-modified IOLs versus 6.27x10(4) (SD 7.70x10(4)) on untreated IOLs. CONCLUSION: The presented in vitro results indicate that Dynasilan surface modification is able to reduce the adherence of S. epidermidis and P. acnes on all IOL materials tested. Further studies regarding the stability of this modification and its biocompatibility must be performed.

Bacterial Adhesion↗

Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecular weight 6 kDa) or polyethyleneglycol (PEG, molecular weight 5 kDa). The preparations obtained were used for MR visualization of axillary and subscapular lymph nodes after SC injection into rabbit's paw. Dextran-modified liposomes were found to have limited or no effect on lymph node/muscle MR signal intensity ratio during the first 2 h after the administration when compared to nonmodified plain liposomes, whereas the liposomes modified with PEG demonstrated a 3-3.5-fold enhancement of lymph node signal. However, the partial biodistribution studies with the 111In-labeled liposomes revealed that PEG-modified vesicles accumulated in the axillary lymph node at half the amount comparing with nonmodified and dextran-modified liposomes. The phenomenon found might be explained by noticeably increased relaxivity of PEG-modified Gd-liposomes.

Animals↗

Effect of the glass surface modification on the strength of methacrylate monolith attachment.

The influence of glass surface modification in order to determine strength of the monolith attachment was studied. Modification consists of pre-treatment of the glass with chemicals or boiling in deionized water, silanization and drying has been investigated on different types of glass. Amount of silane groups was determined by measurement of the contact angle between the glass surface and water drop. The highest values were found for soda-lime glass. Strength of the monolith attachment was established by pumping ethanol through the monolithic capillaries and measuring the pressure drop at which monolith was dislodged. Surprisingly, it was found that the critical part of the glass surface modification procedure is glass pre-treatment. Good results were obtained with glass boiled in water for 2.5 h or more.

Glass↗

Hydrophilic surface modification of metallic endoluminal stents.

PURPOSE: Stainless steel endovascular stents are inherently thrombogenic so that thrombus accumulates on these devices, leading to acute vessel occlusion. A potential solution to this problem is stent surface modification with hydrophilic polymers, which might limit platelet adhesion and reactivity. METHODS: N-vinylpyrrolidone (NVP) and potassium sulfopropyl acrylate (KSPA) hydrophilic monomers were gamma graft polymerized onto 1 cm2 stainless steel slabs and 4 mm Palmaz stainless steel stents. Surface characteristics of modified and plain stainless steel stents were then investigated with contact angle and x-ray photoelectron spectroscopy measurements, and in vitro and in vivo platelet reactivity was assessed as 111Indium platelet accumulation expressed as counts/min/cm2. RESULTS: Surface modification of stainless steel slabs and stents with both NVP and KSPA hydrophilic polymers significantly reduced in vitro platelet adhesion (plain = 2249 +/- 723 counts/min/cm2, NVP = 428 +/- 156 counts/min/cm2, KSPA = 958 +/- 223 counts/min/cm2) and in vivo platelet accumulation after 1 hour of blood flow exposure (plain = 1407 +/- 796 counts/min/cm2, NVP = 426 +/- 175 counts/min/cm2, KSPA = 399 +/- 124 counts/min/cm2. In addition, platelet accumulation on modified stents indexed to plain stents was lowest in KSPA-modified stents (NVP = 79.3% +/- 31.7% of plain, KSPA = 51.2% +/- 36.2% of plain). Surface analysis confirmed surface grafting with both monomers, and SEM documented smoothing of the irregular surfaces of the stainless steel stents after grafting. CONCLUSION: Hydrophilic polymer surface modification of stainless steel stents decreases initial stent surface platelet accumulation, which may decrease the risk of vessel thrombosis associated with the use of these devices.

Blood Vessels↗

A novel dry method for surface modification of SU-8 for immobilization of biomolecules in Bio-MEMS.

SU-8 has been primarily used for structural elements and microfludics components in MEMS. Microsystems for biological applications require immobilization of biomolecules on the MEMS structures. In order to functionalize SU-8 for such purposes, the surface needs to be modified. In this paper, we report a novel dry method of surface modification of SU-8 which is compatible with standard microfabrication techniques. The surface obtained by spin coating SU-8 (2002) on silicon wafer was modified by grafting amine groups using pyrolytic dissociation of ammonia in a hotwire CVD setup. To demonstrate the presence of amine groups on modified SU-8 surface, the surface characteristic after modification was assessed using Fourier transform infrared spectroscopy. The change in SU-8 surface morphology before and after surface modification was investigated using atomic force microscopy. To show the utility of this process for application in Bio-MEMS, SU-8 microcantilevers were fabricated and subjected to the same surface modification protocol. Following this, the cantilevers were incubated first in a suspension of human immunoglobulin (HIgG) and then in FITC tagged goat anti-human IgG in order to demonstrate the utility of the surface modification performed. The efficacy of the process was assessed by observing the cantilevers under a fluorescence microscope.

Acrylic Resins↗

Biocompatibility of polysulfone I. Surface modifications and characterizations.

Surface treatments by nonionic surfactant (Brij) coating and air-plasma glow discharge treatment onto polysulfone have been investigated to improve its surface properties. Surface treated samples were characterized by measurement of contact angle by a goniometer, Fourier transform infrared spectroscopy in the attenuated total reflectance mode (FTIR-ATR), and electron spectroscopy for chemical analysis (ESCA). The contact angles of the nonionic surfactant coated films decreased from 66.6 +/- 2.1 degrees to nearly 0 degrees due to hydrophilic polyethylene oxide (PEO) chain segment of the nonionic surfactant, and those of air-plasma treated films also decreased from 66.6 degrees to about 22 degrees with a treatment time of less than 5 s. ESCA analysis of air-plasma treated films indicates the incorporation of oxygen molecules onto polysulfone surface lowers the water contact angle. These modified techniques can be used to prevent platelet adhesion onto polysulfone surfaces.

Adsorption↗

Surface modification of polymeric biomaterials with poly(ethylene oxide), albumin, and heparin for reduced thrombogenicity.

Appropriate surface modification has significantly improved the blood compatibility of polymeric biomaterials. This article reviews methods of surface modification with water-soluble polymers, such as polyethylene oxide (PEO), albumin, and heparin. PEO is a synthetic, neutral, water-soluble polymer, while albumin and heparin are a natural globular protein and an anionic polysaccharide, respectively. When grafted onto the surface, all three macromolecules share a common feature to reduce thrombogenicity of biomaterials. The reduced thrombogenicity is due to the unique hydrodynamic properties of the grafted macromolecules. In aqueous medium, surface-bound water-soluble polymers are expected to be highly flexible and extend into the bulk solution. Biomaterials grafted with either PEO, albumin, or heparin are able to resist plasma protein adsorption and platelet adhesion predominantly by a steric repulsion mechanism.

Albumins↗

The effect of heparin-surface-modification on scar-tissue formation around a subconjunctival polymethylmethacrylate implant in the rabbit.

PURPOSE: Excessive scar tissue formation around ocular drainage implants is a common cause for implant failure. The purpose of this study was to evaluate the effect of heparin-surface-modification of a subconjunctival polymethylmethacrylate implant on scar-tissue formation in the rabbit eye. METHODS: Plain and heparin-surface-modified polymethylmethacrylate implants were implanted subconjunctivally in the eyes of 13 rabbits in two groups consisting of 8 and 5 animals. In the latter group the implants were in contact with aqueous humour through a fistula into the anterior chamber. RESULTS: Both unmodified and heparin-surface-modified polymethylmethacrylate implants were well tolerated. In histological sections studied by both light microscopy and transmission electron microscopy, heparin-surface-modification of polymethylmethacrylate implants seemed to diminish the formation of scar tissue around the subconjunctival implants. CONCLUSION: Heparin-surface-modification of polymethylmethacrylate implants could provide one way to affect the formation of excessive fibrous tissue around ocular drainage implants.

Animals↗

Fibrinous uveitis and intraocular lens implantation. Surface modification of polymethylmethacrylate during extracapsular cataract surgery.

BACKGROUND: The causes of fibrinous uveitis after cataract surgery are unclear, but surface modification of polymethylmethacrylate (PMMA) is known to influence post-operative inflammation. One hundred twenty-five patients were entered into a prospective investigation designed to assess the effect of intraoperative surface modification of PMMA, by coating with a 2% hydroxypropyl methylcellulose solution, on the incidence of fibrinous uveitis after extracapsular cataract surgery and lens implantation. METHODS: Of the 125 patients entered into this prospective study, 90 received pretreatment with a 1% indomethacin solution. RESULTS: Fibrinous uveitis developed in 18(33%) of 54 eyes with dry lens implantation and in 1 (3%) of 36 eyes with coated lens implantation (P less than 0.005). Thirty-five eyes were not pretreated with indomethacin, and fibrin formation occurred in 6 (30%) of 20 dry implanted eyes and in 0 of 15 eyes with coated lens implantation (S = 0.02). CONCLUSIONS: Intraoperative modification of the PMMA surface of an intraocular lens during implantation significantly reduces the severity of postoperative inflammation, as manifest by the incidence of fibrinous uveitis.

Adult↗

Efficacy of glow discharge gas plasma treatment as a surface modification process for three-dimensional poly (D,L-lactide) scaffolds.

Gas plasma surface modification of three-dimensional poly (D,L-lactide) scaffolds fabricated by a novel vibrating particle fabrication technique was demonstrated to enhance cell adhesion, proliferation, and differentiation over 10 days in culture using human embryonic palatal mesenchyme cells. Characterization of corresponding two-dimensional treated surfaces revealed decreased contact angle measurements of 54.2 +/- 0.6 degrees for treated surfaces compared to 72.3 +/- 0.7 degrees for control surfaces (p < 0.05). SEM of treated surfaces revealed increased surface roughness combined with marked pitting and erosion. This may contribute to increased cell adhesion. WST-1 cell proliferation assay measurements as an index of cell numbers revealed a statistically significant increase in proliferation activity on treated surfaces on days 1 and 4 compared with controls. There was a fivefold increase in WST-1 activity for both control and treated groups over 10 days. Confocal laser micrographs revealed increased cell numbers on treated specimens throughout all layers of the scaffold, indicating that the glow discharge process enhanced cell proliferation throughout the entire scaffold architecture. Scanning electron micrographs demonstrated increased cell adhesion for treated specimens at the polymer surface most evident after days 1 and 4 of culture. Alkaline phosphatase (ALP)-specific activity peaked by day 7 for control and treated surfaces, indicating cellular differentiation. There was a trend for increased protein production on the treated specimens compared with controls at the initial time points although the differences were not statistically significant. These results demonstrated that gas plasma surface modification enhances osteoblast-like cell function in a three-dimensional scaffold model.

Absorbable Implants↗

Starch nanocrystals with large chain surface modifications.

Nanoscale monocrystalline starch particles were successfully modified using stearic acid chloride and poly(ethylene glycol) methyl ether. Surface modification was confirmed using FTIR, XPS spectroscopy, and contact angle measurements. X-ray diffraction and DSC analysis confirmed that there was no alteration of the starch crystalline structure due to the surface modification. The grafts at the starch surface were also found to crystallize on the surface. TEM showed the individualization of nanoparticles as a result of the reduction of polar and hydrogen bonding forces. These results show our ability to modify the starch nanocrystal surface with plasticizing chains. Modified nanoparticles can find applications as compatibilized polymer additives, surface-active particles, and co-continuous nanocomposite precursors.

Calorimetry, Differential Scanning↗

New procedure of silica gel surface modification preparation of gaseous standard mixtures for calibration purposes.

The new type of silica gel surface modification with using the trimethylamine as a reagent is described. The samples of chemically modified silica gel have been used for generation of gaseous standard mixtures (methyl chloride as a measurand) using the technique of thermal decomposition of the surface compound. The main aim of the research was to check the suitability of the new type of silica gel surface modification for obtaining methyl chloride as a measurand of gaseous standard mixture. The gaseous standard mixture obtained with using this technique was used for calibration of a thermal desorber-gas chromatography-flame ionization detector (TD-GC-FID) system. The homogeneity of coverage of silica gel surface with the immobilized compound has been evaluated. The full uncertainty budget of determination of liberated amount of methyl chloride has been calculated. The average amount of methyl chloride liberated from the unit sample of chemically modified silica gel is 3.59 +/- 0.13 mg g(-1). The influence of the modification way on the amount of liberated analyte has also been determined.

Calibration↗

Surface modification of poly(dimethylsiloxane) microchannels.

This review looks at the efforts that are being made to modify the surface of poly(dimethylsiloxane) (PDMS) microchannels, in order to enhance applicability in the field of microfluidics. Many surface modifications of PDMS have been performed for electrophoretic separations, but new modifications are being done for emerging applications such as heterogeneous immunoassays and cell-based bioassays. These new modification techniques are powerful because they impart biospecificity to the microchannel surfaces and reduce protein adsorption. Most of these applications require the use of aqueous or polar solvents, which makes surface modification a very important topic.

Adsorption↗

Surface modification of nanometer size TiO2 with salicylic acid for photocatalytic degradation of 4-nitrophenol.

The efficiency of photocatalytic reactions was limited by the wide band-gap of TiO(2) and the high degree of electron-hole recombination inherent in photocatalytic process, as well as by the limited adsorption capability of photocatalysts. In order to increase the overall efficiency, the surface of nanometer size TiO(2) was simply and fast modified by chemical adsorption in saturated solution of salicylic acid. A stable, light yellow surface complex was formed quickly, which has obvious absorption in the region from 320 to 420 nm. Through surface modification, the adsorption efficiency of 4-nitrophenol by TiO(2) was enhanced from 42 to 84%. The photocatalytic efficiency was tested on the degradation of 4-nitrophenol. The influences of catalyst and its dosage, pH value, and 4-nitrophenol concentration on the degradation were investigated. Under such photodegradation conditions as initial pH 4.0, 4-nitrophenol 5 mg l(-1), catalyst 100 mg, and irradiation time 160 min with 160 W high-pressure mercury lamp, the degradation efficiency of 4-nitrophenol by TiO(2) was increased from 39.5 to 79.3% after surface modification, and furthermore, the degradation efficiency could be enhanced to 91.1% if the concentration of 4-nitrophenol was not more than 1 mg l(-1). Compared with the pure TiO(2), surface modification led not only to improve the surface coverage of 4-nitrophenol, but also to increase the light utilization. Both of these factors were crucial for the photocatalytic activity of heterogeneous photocatalysis, especially for photodegradation of aromatic pollutants.

Adsorption↗

Silicon surface modification with a mixed silanes layer to immobilize proteins for biosensor with imaging ellipsometry.

One kind of surface modification method on silicon wafer was presented in this paper. A mixed silanes layer was used to modify silicon surface and rendered the surface medium hydrophobic. The mixed silanes layer contained two kinds of compounds, aminopropyltriethoxysilane (APTES) and methyltriethoxysilane (MTES). A few of APTES molecules in the layer was used to immobilize covalently human immunoglobulin G (IgG) on the silicon surface. The human IgG molecules immobilized covalently on the modified surface could retain their structures well and bind more antibody molecules than that on silicon surface modified with only APTES. This kind of surface modification method effectively improved the sensitivity of the biosensor with imaging ellipsometry.

Biosensing Techniques↗

Surface modifications of glass-reinforced hydroxyapatite composites.

Surface modifications of glass-reinforced hydroxyapatite composites immersed in a simulated physiological solution were studied using X-ray photoelectron spectroscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. In the first stages of the apatite formation process, calcium and silicon ions were leached out from the surface of the composites. After 12 days of immersion, apatite crystals were detected on the surface indicating bioactive behaviour. Sodium ions attributed to sodium sulphate were also found in the apatite layer. Bound water on the surface also increased with immersion time.

Biocompatible Materials↗

Effects on interfacial properties and cell adhesion of surface modification by pectic hairy regions.

Polystyrene Petri dishes, aminated by a plasma deposition process, were surface modified by the covalent linking of two different enzymatically modified hairy regions (HRs) from pectin containing, for example, rhamnogalacturonan-I and xylogalacturonan structural elements. The two polysaccharide preparations share the same structural elements of apple pectin, but the relative amounts and lengths of the neutral side chains present differ. Surface analysis by X-ray photoelectron spectroscopy, contact angle measurement, and atomic force microscope (AFM) force-separation curves was used to characterize the effects on surface chemistry and interfacial forces of the surface modification process. Cell adhesion experiments using continuous L-929 fibroblasts and primary aortic smooth muscle cells were performed to evaluate the effect of the polysaccharide nature on cell adhesion. Results show that immobilization of the HR affects the interfacial field of forces and the cell behavior: "equilibrium" contact angles, obtained by a recently introduced vibrational approach, decrease after HR immobilization reaching a value close to 20 degrees . AFM force-separation curves show a more extended (or softer) interface in the case of the HR bearing longer side chains. Accordingly, depending on the HR preparation, cells shifted from spread morphology and adhesion behavior quantitatively comparable to that observed on conventional tissue culture polystyrene to rounded morphology and significantly lower adhesion. These data show that engineering of plant pectins can be a valuable tool to prepare novel and finely tuned polysaccharides having different chemico-physical and biological properties, to be used in the surface modification of medical devices and materials.

Animals↗

Surface modification of phenolphthalein poly(ether sulfone) ultrafiltration membranes by blending with acrylonitrile-based copolymer containing ionic groups for imparting surface electrical properties.

Asymmetric ultrafiltration membranes were fabricated from the blends of phenolphthalein polyethersulfone (PES-C) and acrylonitrile copolymers containing charged groups, poly(acrylonitrile-co-acrylamido methylpropane sulfonic acid) (PAN-co-AMPS). From the surface analysis by XPS and ATR-FTIR, it was found that the charged groups tend to accumulate onto the membrane surface. This result indicated that membrane surface modification for imparting surface electrical properties could be carried out by blending charged polymer. Furthermore, with the help of a relatively novel method to measure membrane conduction, the true zeta potentials calculated on the basis of the streaming potential measurements were used to reflect the charge state of membrane surface. In addition, it was noteworthy that, from the profiles of zeta potential versus pH curves and the magnitude of zeta potentials, the determination of zeta potential was dependent not only on the electrical properties of membrane surface but also on its hydrophilicity. At last, based on a relatively elaborate study on the electrostatic interaction between the membrane surface and protein, it was found that these charged membranes could meet different demands of membrane applications, such as resisting protein fouling or protein separation, through adjusting solution pH value.

Journal Article↗