Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “soft-tissue implants”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Total shoulder arthroplasty: complications and revision surgery.

Fortunately, revision surgery after prosthetic shoulder arthroplasty is rarely required. However, various complications or combinations of complications can lead to the need for revision surgery. For many of these, several treatment options are possible. Recognizing all the problems that contributed to failure in an individual patient may be difficult before revision surgery. Understanding the abnormality present at the time of surgery requires considerable experience. For example, glenoid loosening, in addition to being accompanied by scapular bone loss, may be associated with rotator-cuff tearing, instability, or joint contracture. In addition to the component loosening, all of these must also be treated if the revision procedure is to be successful. When addressing glenoid loosening, it seems to be best to revise the component, if possible. If there is extreme bone loss, one may have to bone graft the deficiencies and not replace the glenoid component. Fortunately, clinically significant humeral loosening is rare. When it occurs, revision of the component is justified and almost always possible. In hemiarthroplasties with pain, conversion to a total shoulder arthroplasty by placing a glenoid component is highly effective. In instability after shoulder arthroplasty, soft-tissue repair does not always create stability. Unfortunately, for most patients, component revision is a necessary part of the revision surgery. When rotator-cuff tearing is acute, repair is indicated; for chronic rotator-cuff tearing, repair depends on the severity of the symptoms. When infection develops after shoulder arthroplasty, implant removal is almost always necessary, but occasionally, in low-grade infections, a primary or secondary exchange procedure may be possible.

Humans↗

A sequential three-step lateral release for correcting fixed valgus knee deformities during total knee arthroplasty.

An approach to mild, moderate, and severe fixed valgus deformities of the knee is described. The sequential approach to soft-tissue releases in the fixed valgus knee allows the surgeon to regain a neutral alignment in valgus deformities of up to 90 degrees. An additional benefit of the approach is spontaneous correction of fixed external tibial rotation deformities. Using this approach, early and late stability allows the use of unconstrained knee implants, including those with mobile-bearing elements.

Arthroplasty↗

Oral administration of D-penicillamine causes neonatal mortality without morphological defects in CD-1 mice.

D-Penicillamine (DPA) causes axial skeletal defects in rats and fetal lethality when given as 0.83% and 1.6% of the diet, but its mechanism of action on the axial skeleton is unknown. We have been using submerged fetal CD-1 mouse limb-bud organ cultures to evaluate the mechanisms of teratogenesis in the developing murine limb. Before attempting to evaluate the in vitro effects of DPA, a dose response morphological teratology study was undertaken using CD-1 mice to determine the effects of DPA on the mouse and determine the potential of using the mouse limb-bud assay to investigate the terata produced by DPA. Groups (n = 8) of nulliparous pregnant mice (vaginal plug = day 0 of gestation) were dosed, via oral gavage, with 0, 250, 500, 1000 and 2000 mg kg-1 DPA for the first 12 days of gestation. Body weights and food consumption were measured daily. On day 18, fetuses were removed by Caesarian section. Two-thirds of the fetal skeletons were stained with alcian blue and alizarin red and then cleared and examined for defects. Soft-tissue defects were examined in the remaining one-third using a modification of the Wilson freehand technique. Maternal body weight gains were not different before day 12 of the experiment, but differed in the interval of day 13-18 (P = 0.004). No group differences were noted in male/female ratios, site of implantation, implantation numbers and number of fetuses. Decreased survivability was seen in the 2000 mg kg-1 group. No treatment-related defects were seen.(ABSTRACT TRUNCATED AT 250 WORDS)

Abnormalities, Drug-Induced↗

Remodelling of bone around intramedullary stems in growing patients.

The remodelling of bone around intramedullary cemented stems, used for the fixation of massive distal femoral replacements in young patients, has been studied. Several types of remodelling have been identified, and this is common to all of the retrieved specimens that have been in situ for periods of 6 to 18 months. Transection of cortical bone and the insertion of a massive prosthesis leads to (a) the formation of a pedicle of bone or bony bridge that grows from the transection site over the shaft of the prosthesis, (b) bone resorption at the transection site, (c) the development of an inner porotic cortex surrounding the intramedullary stem and subperiosteal bone formation, and (d) a shell of bone around the acrylic cement. The tibial component that allows continued growth of the proximal tibial physis consists of a press fit metallic plateau with a stem that slides into an ultra-high-molecular-weight polyethylene sleeve inserted below the growth plate. A sclerotic layer of bone forms adjacent to a soft-tissue interface around both the sleeve and the metallic component. Remodelling of bone around intramedullary stems is attributed either to a redeveloping blood supply or to load adaptive changes.

Adolescent↗

Endoprosthetic reconstruction after bone tumor resections of the proximal tibia.

The advent of successful adjuvant chemotherapy and radiation therapy protocols for primary malignant tumors and the development of custom-designed metallic endoprostheses has now made possible a successful limb salvage procedure for malignancies of the proximal tibia. Use of the transposed medial gastrocnemius flap, as proposed by Dr. Jean Duboussett of Paris, has been critical to the soft-tissue reconstruction that routinely permits an excellent active and passive range of motion for these patients. This article describes the operative techniques and technical considerations necessary for a successful proximal tibial endoprosthesis reconstruction.

Bone Neoplasms↗

Orthopedic fixation devices.

Orthopedic fixation devices are used in the treatment of fractures, soft-tissue injuries, and reconstructive surgery. After fracture reduction, internal, external, or intramedullary fixation devices may be used to provide stability and maintain the alignment of bone fragments during the healing process. They must be strong and secure enough to allow early mobilization of the injured part, as well as the entire patient. Compression is used whenever possible to increase the contact area and the stability between fragments and to decrease the stress on the implant. Screws are used primarily to provide interfragmental compression or to attach plates, which can then provide compression, prevent displacement, and support the fragments during healing. Pins and wires can be used for fixation of small fragments or fractures in small bones and for attachment of external fixation devices and traction. A basic understanding of the devices and principles of use is needed to interpret radiographs obtained after the treatment of musculoskeletal injuries.

Fracture Fixation↗

Biocompatibility of surgical-grade dense polycrystalline alumina.

This article reviews the knowledge about biocompatibility of alumina since its introduction as a material for use in joint replacements. Alumina is a hydrophilic material with high wettability allowing very low friction with negligible wear. Macrophages loaded with alumina particles show no morphologic alteration and do not lose their chemotactic ability. The host response has been studied for bulk and particulate alumina in soft tissues, as well as in human and animal bone under loaded and nonloaded conditions. The soft-tissue response to bulk alumina exhibits minimal fibrosis, and direct bone contact is achieved at compression-loaded interfaces. Examination of human biopsies from failed total hip prostheses reveals a foreign-body reaction containing predominantly macrophages loaded with alumina particles. No lymphocyte or plasma-cell infiltration is observed because of the absence of soluble component release. The amount of necrosis and fibrosis was lower than that associated with metal or polyethylene debris. In summary, alumina exhibits greater bioinertness than all other implant materials currently available for joint replacement.

Aluminum Oxide↗

Experimental applications of porous (coralline) hydroxylapatite in middle ear and mastoid reconstruction.

Hydroxylapatite is a ceramic implant material which has been extensively investigated in the orthopedic and oral surgical literature. A set of animal experiments was carried out to determine the feasibility of the use of porous (coralline) hydroxylapatite for middle ear and mastoid reconstruction. Coralline hydroxylapatite was placed in the mastoid bulla of dogs and was carved into struts which were placed into the middle ear and against the tympanic membrane. Coralline hydroxylapatite is a highly biocompatible material which showed abundant ingrowth when in contact with host bone. There was also good soft-tissue ingrowth and fibrous tissue fixation within the middle ear and against the tympanic membrane. Hydroxylapatite is generally accepted to be osteoconductive, but not osteogenic. However, one of the specimens described with chronic inflammatory mucosal changes, shows de novo new bone formation within the pores of the graft. While normally the bone formed in coralline hydroxylapatite is secondary (lamellar), in this specimen primary (woven) bone was found. Porous (coralline) hydroxylapatite appears to be an excellent otologic graft material. It biointegrates with the host, is osteoconductive, and under certain circumstances may be osteogenic.

Animals↗

Osteopromotion for cranioplasty. An experimental study in rats using a membrane technique.

Various techniques for treatment of large cranial defects have been reported, but the use of alloplastic materials still seems to predominate. The authors have applied and explored a new approach for bone repair which appears promising, even for use in less osteogenic environments such as the adult calvaria. Seventy-two adult Sprague-Dawley rats each received bilateral 8-mm trephine defects in the temporoparietal area; this defect size precludes spontaneous osseous healing during the lifetime of the animal. Five surgical procedures, employing various alternatives of biologically inert expanded polytetrafluoroethylene membrane positioning and intramembranous bone-chip implantation, were performed and compared to control defects. Slight improvement of bone regeneration was demonstrated with subperiosteal ectocranial and endocranial membranes, alone or in combination, and with bone chips alone or in combination with an outer or inner membrane. Virtually complete bone healing was observed in animals receiving both an outer and an inner membrane with interpositioned bone chips. The latter appeared to function primarily as space-holders by keeping the membranes separated throughout the defect. Consequently, this technique seems to significantly promote bone repair by excluding soft-tissue components from the bone-healing site.

Animals↗

The use of Gore-Tex implants in aesthetic surgery of the face.

Deep wrinkles and folds usually are not completely or permanently corrected with face lifting, fat or collagen injections, chemical peels, and other known procedures. It is suggested that a permanent implant, well tolerated by human tissues, could be helpful as an isolated or associated procedure. An expanded synthetic polymer known as Gore-Tex expanded polytetrafluoroethylene soft-tissue patch is available and is easy to use to approximate and correct defects; it also can be used as a filling material or to replace other kinds of prostheses to get better projection of frontal, orbital, malar, and chin areas. I have used this material in my clinic for 5 years. Indications and results of the first cosmetic cases are reported herein.

Adolescent↗

[Epitheses of the face].

Despite progress in maxillofacial cancer surgery, most patients present disfiguration of their faces. External prostheses are a pleasing alternative to camouflaging maxillofacial mutilations after tumor ablation. Established indications for external prosthesis are: 1. the patient refusing soft-tissue reconstruction, 2. patient's multimorbidity, and, 3. the impossibility of fully reconstructing a specific maxillofacial defect. Consequently, the benefits of applying external prosthesis include the simple camouflage of an unsightly tumor defect, the ease in supervising any possible local tumor growth beneath the external prosthesis as well as helping to prevent patient's isolation. Thus, external prostheses are a good option in the rehabilitation of maxillofacial surgery patients.

Adult↗

A method for reconstruction of large full-thickness defects of the bony thorax.

Wide resection in 12 cases of malignant or potentially malignant lesions of the chest wall resulted in full-thickness loss of skeleton and frequently of overlying soft tissues (defect greater than or equal to 15 cm in its smallest diameter or at least 90% of the sternum resected). In reconstruction of the defect, steel bars were used to replace lost ribs and a double layer of Marlex mesh for intercostal spaces. Soft-tissue coverage and primary closure were accomplished with current plastic surgical procedures and good stability of the chest wall was achieved. Protracted respiratory support was required in only one case. Postoperative pain was managed with epidural anesthesia and routine analgesics. Functionally and cosmetically satisfactory long-term results were obtained, with no infection and no need for removal of prosthetic material. The overall 5-year and 10-year actuarial survival rates were 60% and 37.5%. If lesions are radically resectable, the extent of thoracic wall resection need not be restricted because of inability to close the defects.

Adult↗

[Favorable results of the surgical treatment of intra-articular crush fractures of the distal femur].

Severely comminuted intra-articular femoral fractures are usually associated with major soft-tissue damage as a part of serious multiple injuries. Surgical treatment should aim at exact anatomical restoration of the articular surface. Internal fixation should be stable so that functional after-treatment is possible, a condition of achieving an optimal result. In a period of over 7 years, 24 patients with 26 intra-articular comminuted fractures were operated on. Twenty patients had multiple injuries (ISS > 18), 11 fractures were complicated. Postoperatively, impaired wound healing occurred in three elderly patients; in two of these amputation was necessary. Considering the severity of the injury, the long-term results were good: ten of the 16 patients examined with 18 fractures recovered completely, in the other cases the functional result wa adequate to good. Surgical treatment of comminuted intra-articular fractures of the distal femur is to be adapted to the individual case; depending on the fracture type and the associated damage a selection is to be made from various implants and techniques. With consistent, individually adapted application of the current AO techniques good results can be obtained.

Adult↗

Quantitative analysis of lidocaine hydrochloride delivery by diffusion across tissue expander membranes.

Permeability of Silastic tissue expander shells to lidocaine was studied to investigate the feasibility of intraluminal lidocaine injection for pain relief during soft-tissue expansion. Both intact expanders and an apparatus using isolated Silastic membrane segments were used to partition solutions of various lidocaine concentrations, and the rate of diffusion was quantitatively measured using a fluorescence polarization immunoassay. Lidocaine flux was found to follow Fick's law of passive diffusion with respect to time, surface area, and concentration gradient for the first 9 hours, with a permeability coefficient of 10.3 +/- 2.6 micrograms (h.cm2.percent)-1 (mean +/- SD) and diffusion coefficient of 7.5 x 10(-7) cm2/min for an average membrane thickness of 473 +/- 23 microns. After 9 hours, the lidocaine flux decreased exponentially, although the concentration gradient across the membrane remained essentially the same order of magnitude. Plasma proteins in the outer bathing solution and methylparaben used as a preservative in the standard lidocaine formulation had no influence on the change in transport flux with time. At the end of the linear portion of the diffusion curve, less than 2 percent of the total intraluminal lidocaine had crossed the membrane. Potential toxicity in the event of implant rupture limits the maximum total lidocaine dose to approximately 500 mg within an expander at any one time. Within these limits, the capacity for lidocaine delivery of 500 mg lidocaine by a 640-cc tissue expander would be only 6 mg during the first 9 hours after administration.(ABSTRACT TRUNCATED AT 250 WORDS)

Diffusion↗

A clinical evaluation of resorbable hydroxylapatite for the repair of human intra-osseous defects.

One of the goals of periodontal therapy is actual hard- and soft-tissue regeneration or at least the functional repair of periodontal defects. Alloplastic materials used in the past included dense hydroxylapatite grafts which were non-resorbable and often exfoliated. A new resorbable hydroxylapatite biomaterial [OsteoGen (HA RESORB)] was used during flap surgery. After the usual initial therapy, full-thickness flaps were elevated. A through debridement of the roots and osseous defects was accomplished. The defects were measured and then filled with OsteoGen. The mean initial bone defect depth was 4.47 mm. These defects were re-evaluated by the probing of bone levels after a 4-6-month healing period. A mean of 2.26 mm of new bone fill was obtained. This represents an average fill of 51%. Seventeen of the 22 defects had 42% or more actual new bone fill. No foreign body reaction or exfoliation occurred.

Alveolar Bone Loss↗

Analysis of silicon in human breast and capsular tissue surrounding prostheses and expanders.

Diffusion of polydimethylsiloxane from silicone breast prostheses and soft-tissue expanders has been associated with capsular contraction. We used electron dispersive x-ray analysis and scanning electron microscopy to assess the presence of silicon in capsular tissue surrounding three categories of breast prostheses and expanders. Breast and subcutaneous tissues external to the capsules were used as control specimens. Semiquantitative results allowed capsules to be ranked according to implant type. Silicon was localized within the inner 2.0 mm of capsular tissue. The analyses of tissues from 2 patients exhibiting unilateral, Baker grade IV contraction after bilateral placement of prostheses showed less silicon present in the severely contracted capsule than in the less-contracted capsule. Results from this study diminish the importance of silicon as the initiator of capsular contraction.

Breast Diseases↗

Use of a calf prosthesis and tissue expansion in aesthetic reconstruction of the leg.

We present a technique for reconstruction of the legs in patients with soft-tissue loss and formation of large scars with retraction of this tissue in the pretibial region. In such patients, a subcutaneous tissue expander is placed in the region adjacent to the scar tissue. With expansion, we obtained sufficient skin for use in the reconstruction, and the resulting asymmetry in leg diameter was compensated for by means of one or two calf prostheses, depending on the patient.

Adult↗

Ultrasonographic measurement of the soft-tissue of the upper jaw.

For preimplantation diagnoses, various mechanical methods for measuring the width of the soft tissue and thus measuring indirectly the osseous bed of the implant can be used. The ability to determine soft tissue thickness above the jaw by ultrasound was evaluated in 8 autopsy specimens. The data obtained were compared with findings from the needle measurement method which is usually employed in clinical practice. The ultrasound measurement method produced realistic data in all sectional planes chosen.

Anthropometry↗