Diagnostic performance of Food and Drug Administration-cleared serologic assays for natural rubber latex-specific IgE antibody. The Multi-Center Latex Skin Testing Study Task Force.

BACKGROUND: In the absence of Food and Drug Administration-approved natural rubber latex skin testing reagents, latex-specific IgE antibody immunoassays are used in the diagnosis of latex allergy. Comparative diagnostic performance of these tests has not been definitively determined. OBJECTIVE: We sought to study the predictive value of available Food and Drug Administration (510K)-cleared latex-specific IgE antibody immunoassays in the diagnosis of latex allergy. METHODS: Subjects (n = 312) were classified as having a positive (n = 117) or a negative (n = 195) latex allergy history (Hx) or having a positive (n = 131) or a negative (n = 181) puncture skin test (PST) response (Greer reagent). The 14 subjects with a negative Hx and a positive PST response had negative responses to glove provocation testing and thus were considered sensitized but asymptomatic. Sera from 22 subjects were split to evaluate intra-assay variation. All 334 coded sera were analyzed for latex-specific IgE antibodies in the Diagnostic Products Corporation microplate AlaSTAT, Hycor HY-TEC EIA System, and Pharmacia-UpJohn CAP System. Variance and diagnostic performance parameters of each test were computed with 95% confidence intervals in relation to the subjects' Hx and PST status. RESULTS: Intra-assay concordance of split sera results was 96.0% for all 3 assays, with coefficients of variation of less than 25% and between-assay coefficients of variation of less than 21%. The diagnostic performance of the CAP and AlaSTAT assays were equivalent in comparison with PST results: sensitivity, CAP 76.3% and ALASTAT 73. 3% and specificity, CAP 96.7% and AlaSTAT 97.2% (P = NS). The HY-TEC assay was more sensitive (91.6%) and less specific (73.3%) than the CAP and AlaSTAT assays (P <.001). From 9% to 25% of the sera were discordant, being positive in at least 1, but not all 3, assays. CONCLUSION: The CAP and AlaSTAT assays produce 24% and 27% of false-negative results, respectively, whereas the HY-TEC produces 27% of false-positive results when compared with the PST.

Antibodies, Anti-Idiotypic↗

[Diagnostic performance of retrospectively ECG-gated multislice CT of acute pulmonary embolism].

AIM: This study determined the diagnostic performance of ECG-gated MSCT in comparison with conventional MSCT. MATERIALS AND METHODS: Forty-five consecutive patients prospectively underwent ECG-gated (group 1, n = 23) or non-ECG-gated (group 2, n = 22) 8-slice MSCT of the pulmonary arteries. Image data were interactively evaluated by three independent chest radiologists with respect to the presence of emboli at different arterial levels, and with regard to cardiac motion artefacts. Consensus reading by two experienced chest radiologists served as diagnostic gold standard. ROC analysis was carried out for the different vascular sections. RESULTS: Twenty-five patients (56 %) were diagnosed to have pulmonary embolism (13 from group 1, 12 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70 % in group 2 versus 13 % in group 1, p < 0.05). There was no significant difference between the two groups in the overall sensitivities (0.92 vs. 0.95) and specificities (0.92 vs. 0.98) or in sensitivities and specificities at any assessed pulmonary arterial level. CONCLUSION: ECG-gated MSCT pulmonary angiography does not significantly influence the diagnostic performance of MSCT in these patients. Therefore no recommendation for routine clinical practice can be given.

Adolescent↗

Characterization of hypoechoic focal hepatic lesions in patients with fatty liver: diagnostic performance and confidence of contrast-enhanced ultrasound.

The objective of this study was to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) to characterize hypoechoic focal hepatic lesions (HFHL) in fatty liver (FL). A study group of 105 patients with FL and 105 HFHLs (52 malignant and 53 benign) underwent CEUS after SonoVue administration. Two blinded readers independently reviewed baseline ultrasound (US) and CEUS scans and classified each lesion as malignant or benign on a five-point scale of confidence, and recorded whether further imaging work-up was needed. Sensitivity, specificity, areas under the receiver operating characteristic (ROC) curve (A (z)), and interobserver agreement were calculated. We observed that the diagnostic confidence improved after reviewing CEUS scans for both readers (A (z)=0.706 and 0.999 and A (z)=0.665 and 0.990 at baseline US and CEUS, respectively; p<0.0001). Inter-reader agreement increased (weighted k=0.748 at baseline US vs. 0.882 at CEUS). For both readers, after CEUS, the occurrence of correctly characterized lesions increased (from 27/105 [27.5%] to 94/105 [89.5%], and from 19/105 [18.1%] to 93/105 [88.6%], respectively; p<0.0001) and the need for further imaging decreased (from 93/105 [88.6%] to 26/105 [24.8%], and from 96/105 [91.4%] to 40/105 [38.1%], respectively; p<0.0001). We conclude that CEUS improves the diagnostic performance of radiologists in the characterization of HFHLs in FL and reduces the need for further imaging work-up.

Adenoma, Liver Cell↗

Comparative diagnostic performance of TACT slices and its multiple source images: an in vitro study.

OBJECTIVE: To compare the diagnostic performances provided by tuned aperture computed tomography (TACT) slices and the multiple images that they originate from in the detection of primary caries on the proximal surfaces of posterior teeth. STUDY DESIGN: Eight direct digital radiography images of each of 40 posterior teeth were acquired with a digital sensor. These source images were used to generate TACT slices of the teeth. Eight trained observers were calibrated in the use of both TACT slices and the eight source images of each tooth. They were asked to assess the presence/absence of proximal caries in the teeth using a 5-point rating scale. Observers' assessments were compared with the ground truth provided by histological examination of tooth sections. Areas under the receiver operating characteristic (ROC) curves (Az) were calculated for each combination of observer and image modality. Analysis of variance (ANOVA) was used to test the ROC values for potential statistical differences. RESULTS: Mean ROC Az values were 0.760 for TACT slices and 0.771 for its multiple source images for the detection of primary proximal caries. ANOVA showed no statistically significant differences either between modalities (P = 0.656) or between observers (P = 0.851). CONCLUSION: TACT slices and its multiple source images provide comparable diagnostic performance for proximal caries detection.

Analysis of Variance↗

Diagnostic performance of MR arthrography after rotator cuff repair.

OBJECTIVE: The objective of this study was to investigate the diagnostic performance of MR arthrography after rotator cuff repair. MATERIALS AND METHODS: MR arthrographic examinations of the shoulder performed after rotator cuff repair and before revision surgery were retrospectively analyzed in 48 patients (31 males, 17 females; mean age, 50.3 years; age range, 17-69 years). Full-thickness and partial-thickness defects of the supraspinatus, infraspinatus, and subscapularis tendons were diagnosed independently by two radiologists. Revision surgery served as the standard of reference. RESULTS: Observer 1 correctly recognized five of eight intact supraspinatus tendons, 10 of 19 partial-thickness defects, and 19 of 21 full-thickness defects. For observer 2, the numbers were three of eight, eight of 19, and 18 of 21. The corresponding numbers for the infraspinatus tendon for observer 1 were 28 of 31, 0 of three, and 14 of 14 tendons. For observer 2, they were 28 of 31, two of three, and 11 of 14. For the subscapularis tendon, observer 1 made the correct diagnosis in 18 of 31, five of six, and nine of 11 tendons. The results for observer 2 were 26 of 31, one of six, and 10 of 11 tendons. Interobserver agreement (weighted kappa) was 0.47 for the supraspinatus, 0.64 for the infraspinatus, and 0.20 for the subscapularis tendons, respectively. CONCLUSION: Postoperative full-thickness defects of the rotator cuff are reliably diagnosed with MR arthrography. The diagnostic performance for partial-thickness defects is only moderate.

Adolescent↗

Regional cerebral saturation monitoring with near-infrared spectroscopy during selective antegrade cerebral perfusion: diagnostic performance and relationship to postoperative stroke.

OBJECTIVE: To investigate whether regional cerebral tissue oxygen saturation monitoring during hypothermic selective antegrade cerebral perfusion in surgery involving the aortic arch can predict neurologic sequelae and to evaluate the diagnostic performance of near-infrared spectroscopy monitoring in this setting. METHODS: Data from 46 consecutive patients were analyzed. Selective antegrade cerebral perfusion was established by perfusion of the right subclavian artery (with or without left carotid artery perfusion) or by separate concomitant perfusion of the innominate and the left carotid arteries. The bilateral regional cerebral tissue oxygen saturation index was monitored by using near-infrared spectroscopy equipment (INVOS 4100). Stroke was the primary clinical end point, along with the indices of diagnostic performance. RESULTS: Six patients died in the hospital, and 6 patients (13%) experienced a perioperative stroke. In patients with stroke, regional cerebral tissue oxygen saturation values were significantly lower during selective antegrade cerebral perfusion, and regional cerebral tissue oxygen saturation tended to be lower in the affected hemisphere. In receiver operating characteristic curve analysis, the area under the curve for relative regional cerebral tissue oxygen saturation values ranged from 0.72 to 0.87. During selective antegrade cerebral perfusion, regional cerebral tissue oxygen saturation between 76% and 86% of baseline had a sensitivity up to 83% and a specificity up to 94% in identifying individuals with stroke. The associated odds ratio for stroke was 5.6 (95% confidence interval, 0.5-144) to 21 (95% confidence interval, 1.8-566). CONCLUSIONS: Monitoring of regional cerebral tissue oxygen saturation by using near-infrared spectroscopy during selective antegrade cerebral perfusion allows detection of clinically important cerebral desaturation. It can help predict perioperative neurologic sequelae. Its performance as a diagnostic instrument is satisfying and supports its use as a noninvasive trend monitor of cerebral saturation.

Aged↗

Diagnostic performance of whole body dual modality 18F-FDG PET/CT imaging for N- and M-staging of malignant melanoma: experience with 250 consecutive patients.

PURPOSE: To assess the diagnostic performance of positron emission tomography/computed tomography (PET/CT) using (18)F-fluorodeoxyglucose (FDG) for N- and M-staging of cutaneous melanoma. PATIENTS AND METHODS: This is a retrospective and blinded study of 250 consecutive patients (105 women, 145 men; age 58 +/- 16 years) who underwent FDG-PET/CT for staging of cutaneous melanoma at different time points in the course of disease. Whole-body FDG-PET/CT was performed 101 +/- 21 minutes postinjection of 371 +/- 41 MBq FDG. Diagnostic accuracy for N- and M-staging was determined for CT alone, PET alone, and PET/CT. RESULTS: PET/CT detected significantly more visceral and nonvisceral metastases than PET alone and CT alone (98.7%, 88.8%, and 69.7%, respectively). PET/CT imaging thus provided significantly more accurate interpretations regarding overall N- and M-staging than PET alone and CT alone. Overall N- and M-stage was correctly determined by PET/CT in 243 of 250 patients (97.2%; 95% CI, 95.2% to 99.4%) compared with 232 patients (92.8%; 95% CI, 89.6% to 96.0%) by PET, and 197 patients (78.8%; 95% CI, 73.7% to 83.9%) by CT. All differences were significant. Accuracy of PET/CT was significantly higher than that of PET and CT for M-staging (0.98 v 0.93 and 0.84) and significantly higher than that of CT for N-Staging (0.98 v 0.86). Change of treatment according to PET/CT findings occurred in 121 patients (48.4%). CONCLUSION: The diagnostic performance of FDG-PET/CT for N- and M-staging of melanoma patients suggests its use for whole-body tumor staging, especially for detection or exclusion of distant metastases.

Adult↗

Time-dependent diagnostic performance of a rapid troponin T version 2 bedside test in patients with acute coronary syndromes.

In a prospective trial, the diagnostic performance of the second version of the troponin T rapid assay (Trop T; cutoff 0.2 microg/L) was compared with the quantitative cardiac-specific troponin T assay (cTnT ELISA; cutoff 0.1 microg/L) and other established cardiac markers such as CK, CK-MB activity, CK-MB mass and myoglobin. Additionally, a 30-day follow-up was performed to determine the suitability of the Trop T assay and the reference markers for short-term risk stratification. Two-hundred-and-eighty-six consecutive patients with chest pain and suspected acute myocardial infarction (AMI) were enrolled in two CCU departments. Serial blood specimens were taken at admission and at 3, 6, 12, 24, 48, 72 and 96 h after admission. According to the biochemical criterion CK-MB mass, the patients were classified as having AMI in 154 patients (54%), unstable angina (UAP) in 72 patients (27%) and no evidence for acute cardiac ischemia in 55 patients (19%). Analytical method comparison of Trop T with cTnT ELISA (cutoff 0.1 microg/L) showed a good agreement, Trop T yielded only 4% false-negative and 3% false-positive results. The diagnostic performance of Trop T for the detection of AMI was only slightly inferior compared to cTnT ELISA. Beyond 12 h after admission, Trop T and cTnT ELISA maintained a sensitivity close to 100%, whereas the sensitivity of the other cardiac markers decreased sharply. The diagnostic sensitivity of Trop T for the detection of minor myocardial damage in UAP patients was the same as for cTnT ELISA. Death within 30 days' follow-up occurred only in AMI patients with a positive Trop T test result within the first 6 h after admission. The admission Trop T and cTnT ELISA were the only significant biochemical predictors of major cardiac events. In conclusion, these data show that Trop T has similar diagnostic sensitivity as cTnT ELISA and is a useful tool to confirm acute or subacute myocardial infarction. Trop T is an excellent marker in detecting minor myocardial damage in UAP patients and is suitable for short-term risk stratification.

Angina, Unstable↗

Evaluation of the diagnostic performance of the expert EMG assistant MUNIN.

The diagnostic performance of the medical expert system MUNIN for diagnosis of neuromuscular disorders was evaluated on a set of 30 test cases. The cases were provided by 7 experienced electromyographers who were subsequently invited to participate in the evaluation. To reasonably cover the range of disorders, the electromyographers were asked to provide cases from patients with different types of muscular dystrophy, with neuromuscular transmission disorders, with motor neurone disease, and with different types of polyneuropathies. In addition, patients with a range of local neuropathies were provided. Out of the 30 cases, 11 cases were evaluated by an "almost peer review" method and the remaining 19 cases were evaluated by a "silver standard" method. The number of cases evaluated by "almost peer review" was limited to 11 due to time constraints on the evaluation procedure. During the "almost peer review," each electromyographer was asked to diagnose patients, using a vocabulary that closely resembled MUNIN's vocabulary. Subsequently, we attempted to provide a consensus diagnosis for the patients based on discussion among the participating electromyographers. The electromyographers were also asked to assess how well MUNIN had performed in each case. The remaining 19 cases were evaluated by a "silver standard" procedure, where MUNIN's diagnosis was compared to the diagnosis of the expert who provided the case. The results indicated that MUNIN performed well, and the electromyographers considered "that MUNIN performed at the same level as an experienced neurophysiologist." In particular, it was noted that MUNIN handled cases with conflicting findings well, and that it was able to diagnose patients with multiple diseases.

Diagnostic Services↗

Lyme borreliosis in Sweden--diagnostic performance of five commercial Borrelia serology kits using sera from well-defined patient groups.

Five commercial Borrelia serology kits available in Sweden were evaluated and compared for their diagnostic performance in sera from clinically well-characterized patient groups. With the clinically defined groups as the gold standard, i.e. without knowledge of antibody status in serum and cerebrospinal fluid, the diagnostic performance of the kits was compared and important differences in diagnostic usefulness were found. The kits from Abbot and DAKO, that often predict clinically relevant Borrelia infection and do not detect antibodies in sera from patients without strong suspicion of Borrelia infection, were considered the most useful in the population studied. This kind of validation study is an important part of good laboratory practice and should be performed by laboratories serving patient populations with varying endemicity of Borrelia.

Antibodies, Bacterial↗

The diagnostic performance of vertebral displacement measurements derived from ultrasonic indentation in an in vivo model of degenerative disc disease.

STUDY DESIGN: The diagnostic performance of a newly described variable was assessed in an in vivo model of disc degeneration using a split-pair experimental design. OBJECTIVE: To determine if vertebral displacement measures generated from ultrasonic indentation could distinguish between experimental and control groups of animals. SUMMARY OF BACKGROUND DATA: Few procedures are available that noninvasively assess subcutaneous vertebral mechanics. Information from such a procedure would be of value in determining potential clinical relevance of spinal mechanics with respect to low back pain. METHODS: Eight adolescent pigs underwent endplate perforation surgery to initiate lumbar disc degeneration. After 4 months of recovery, these and eight age-matched controls were assessed by ultrasonic indentation, a noninvasive procedure that quantifies vertebral displacements in the plane of loading-indentation. Each animal then received a facetectomy and was reindented at the same location as confirmed by ultrasonic imaging. Discal materials were removed postmortem for analysis. RESULTS: Degenerative discs exhibited morphologic changes consistent with early degenerative disc disease. Prefacetectomy comparison of vertebral displacement measures between control and experimental animals resulted in sensitivity, specificity, and diagnostic accuracy values of 75.0%, 83.3%, and 77%, respectively. After facetectomy these values increased to 87.5%, 83.3%, and 85%, respectively. These measures of diagnostic performance were comparable or superior to those of existing clinical techniques (invasive or otherwise) used to assess degenerative conditions of the spine. CONCLUSIONS: The results of this study suggest that noninvasive measures of vertebral displacement are clinically significant and possess the additional advantages of being objective and noninvasive.

Animals↗

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans↗

MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls.

The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs.

Adult↗

Diagnostic performance of various QTc interval formulas in a large family with long QT syndrome type 3: Bazett's formula not so bad after all...

BACKGROUND: Recently, we identified a novel mutation of SCN5A (1795insD) in a large family with LQTS3. The aim of this study was to assess whether the various proposed corrections of the QT interval to heart rate help to improve the identification of carriers of the mutant gene. METHODS: The study group consisted of 101 adult family members: 57 carriers and 44 noncarriers (mean age 44.6 +/- 14.6 and 40.3 +/- 12.8 years, respectively). In all individuals a 12-lead ECG, exercise ECG, and 24-hour Holter ECG were obtained. RESULTS: Correction for heart rate significantly improved the diagnostic performance of the QT interval. Diagnostic performance of the Bazett formula was similar to that of the newer formulas (Fridericia, Hodges, Framingham, and a logarithmic formula). At a cut-off value of 440 ms, the Bazett corrected QT interval was associated with a sensitivity and specificity of 90% and 91%, respectively. Using the 24-hour Holter ECG, a prolonged QTc at heart rates less than 60 beats/min was almost pathognomonic for genetic mutation (sensitivity and specificity both 99%), whereas the QTc calculated at the lowest heart rate using Bazett's formula provided full discrimination. CONCLUSION: In the present family, the resting ECG gave a good indication about the presence or absence of genetic mutation but a 24-hour Holter recording was mandatory to ascertain the diagnosis. In the diagnosis of this form of LQTS3, Bazett's formula was at least as good as other proposed corrections of the QT interval to heart rate.

Adult↗

Impact of atrial fibrillation on the diagnostic performance of B-type natriuretic peptide concentration in dyspneic patients: an analysis from the breathing not properly multinational study.

OBJECTIVES: This study was designed to assess the diagnostic performance of B-type natriuretic peptide (BNP) in the diagnosis of acute congestive heart failure (CHF) in patients with permanent/paroxysmal atrial fibrillation (AF) presenting with acute dyspnea. BACKGROUND: It is unknown to what extent AF affects the diagnostic performance of BNP in patients presenting with acute dyspnea. METHODS: We studied 1,431 patients drawn from a cohort of patients (n = 1,586) with acute dyspnea who had BNP levels measured on arrival. Patients were prospectively classified according to the presence or absence of permanent/paroxysmal AF. RESULTS: In total, 292 patients had permanent/paroxysmal AF. In patients without HF, permanent/paroxysmal AF was associated with significantly higher BNP levels (p = 0.001). Conversely, in patients with HF, BNP levels did not differ significantly between patients with and without AF (p = 0.533). A BNP cutoff value of 100 pg/ml had a specificity of 40% and 79% for the diagnosis of acute HF in patients with and without AF, respectively. The areas under the receiver-operating characteristic curves were 0.84 (95% confidence interval 0.78 to 0.89) and 0.91 (95% confidence interval 0.89 to 0.93) for patients with and without AF, respectively. CONCLUSIONS: In patients without, but not in those with HF, the presence of AF is associated with higher circulating BNP levels, suggesting that a higher diagnostic threshold should be used in patients with AF.

Acute Disease↗

Digital radiography versus conventional radiography in chest imaging: diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study.

OBJECTIVE: The objective of this study was to compare the diagnostic performance of a digital large-area silicon flat-panel detector with that of a conventional screen-film system in clinical chest imaging using abnormal findings documented by CT as the reference standard. SUBJECTS AND METHODS: Eighty patients (46 men and 34 women; age range,18-91 years; mean age, 63 years) who underwent CT of the chest were examined with the new digital radiography system, which is based on a 43 x 43 cm silicon flat-panel detector, and with a conventional screen-film system, which is used routinely in clinical practice. Posteroanterior and lateral radiographs were obtained. Four radiologists analyzed the digital and conventional images separately for chest abnormalities and rated the images using a five-level scale of confidence; CT was used as the reference standard. Diagnostic value was assessed using receiver operating characteristic curves for each abnormality. RESULTS: No significant differences were found between the area under the receiver operating characteristic curve of the digital and that of the conventional radiography method for almost all investigated criteria. The only exception was mediastinal abnormalities, for which the digital method provided better results than the conventional method (p < 0.05). CONCLUSION: The diagnostic performance of the new large-area silicon flat-panel detector is equivalent or superior to that of the conventional screen-film system for clinical chest imaging and can replace conventional radiography systems. This new technology offers transmission and storage possibilities inherent to digital radiology that would facilitate daily practice and reduce the initial high costs in the long-term.

Adolescent↗

MR arthrography of the hip: diagnostic performance of a dedicated water-excitation 3D double-echo steady-state sequence to detect cartilage lesions.

OBJECTIVE: The objective of our study was to compare the diagnostic performance of a dedicated cartilage MR sequence (water-excitation 3D double-echo steady-state) with a standard MR sequence (T1-weighted spin-echo) in detecting articular cartilage lesions of the hip after intraarticular injection of gadopentetate dimeglumine. MATERIALS AND METHODS: In 50 MR arthrograms of the hip joint obtained in 47 consecutive patients, a sagittal 3D double-echo steady-state sequence (TR/TE, 24/6.5; flip angle, 25 degrees ) was compared with a sagittal T1-weighted spin-echo sequence (350/14). Two musculoskeletal radiologists independently evaluated articular cartilage. Sensitivity and specificity for detecting cartilage defects were calculated for those hips that underwent open surgery (n = 21). Lesion conspicuity was retrospectively reviewed and graded between 1 (not visible) and 5 (well defined). RESULTS: At surgery, a total of 26 lesions of the acetabular (n = 20) and femoral (n = 6) cartilage were found. For the 3D double-echo steady-state and T1-weighted spin-echo sequences, sensitivities and specificities for cartilage lesion detection were 58% and 88% and 81% and 81% for reviewer 1 and 62% and 94% and 62% and 100% for reviewer 2, respectively. Lesion conspicuity was significantly superior (p = 0.036) for the 3D double-echo steady-state sequence (mean grade, 3.4) compared with the T1-weighted spin-echo sequence (mean grade, 3.0). The kappa value was fair for the 3D double-echo steady-state sequence (kappa = 0.40) and moderate for the T1-weighted spin-echo sequence (kappa = 0.55). CONCLUSION: The 3D double-echo steady-state sequence optimized for cartilage imaging improves lesion conspicuity but does not improve diagnostic performance.

Adult↗

Receiver-operating characteristic as a tool for evaluating the diagnostic performance of prostate-specific antigen and its molecular forms--What has to be considered?

BACKGROUND: Receiver-operating characteristic (ROC) analysis is often applied as evaluation tool to compare the diagnostic validity of laboratory tests. The aim of this study was to draw attention to preconditions which should be taken into account when ROC analysis is used to assess the diagnostic performance of total prostate-specific antigen (tPSA) and its molecular forms in differential diagnosis between prostate cancer and benign prostatic hyperplasia (BPH). METHODS: Using a standard software (GraphROC for Windows), ROC analyses were performed and the areas under the curves were calculated for four hypothetical pairs of groups. Every group included 40 patients with prostate cancer and with BPH showing different tPSA concentrations (range of 2-10 microg, but similar free-to-total PSA ratios (fPSA%). RESULTS: The area under the fPSA% ROC curve showed the highest value, whereas the areas under the tPSA ROC curves were dependent on the distributions of tPSA concentrations in the patients. The ability of fPSA% to improve the differential diagnosis between prostate cancer and BPH in comparison to tPSA was not furthermore evident, if the prostate cancer group included more patients with higher tPSA concentrations than the BPH group. CONCLUSIONS: When the diagnostic performance of tPSA and its derivatives like molecular forms in patients with prostate cancer and BPH should be compared by ROC analysis, a matching procedure is recommended prior to ROC analysis to compensate the effect of possible unequal tPSA distributions in both groups. Each BPH (or PCa) patient should be matched with a PCa (or BPH) patient with nearest tPSA concentration so that an optimum of overlapping tPSA concentrations in both groups can be achieved.

Diagnosis, Differential↗