[Vacuum aspiration of the endometrium by means of a vacuum curet].
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: To characterize the performance of vacuum equipment used in operative vaginal deliveries. STUDY METHOD: We measured wall suction in eight Cleveland area labor-and-delivery units. Additionally, we tested samples of hand-operated and electric vacuum pumps. For each apparatus we recorded vacuum in millimeters of mercury using a calibrated, diaphragm-type gauge. We calculated mean maximal vacuum. Work required to produce 500 mm Hg of vacuum was determined for the hand-operated pumps. At increments of vacuum, we compared the vacuum displayed by the gauge head included with the device to our standard. RESULTS: Mean wall suction was 494 mm Hg (range, 248-655). As compared to the Mity-vac, the CMI hand-operated pump needed significantly more work to generate 500 mm Hg of vacuum. Electric pumps produced a reliable and consistent vacuum. Gauges included with the pump had an average error of 4% over 400-600 mm Hg. CONCLUSION: Wall suction was an unreliable source of vacuum. The two hand-operated pumps tested required significantly different amounts of work to achieve an adequate vacuum. Addition of a fluid trap does not affect the vacuum, and head gauges supplied with vacuum pumps are accurate.
Simplex P bone cement was prepared in three commercially available vacuum mixing systems, the Enhancement Mixer, the Mixevac II High Vacuum System, and the Mitab Vacuum System, to determine the improvement in fatigue strength associated with porosity reduction of the cement in all three systems. The results of the fatigue tests of vacuum-mixed Simplex P were also compared to the fatigue strength of Simplex P prepared by centrifugation of the cement immediately after mixing. Vacuum mixing one pack of Simplex P per syringe in all three systems was not effective in complete removal of all the large voids from the cement. Fatigue failure occurred very early in those specimens containing the large voids. There was no significant difference in fatigue life between one pack of cement per syringe mixed under vacuum in the three systems and the control cement (no vacuum, uncentrifuged). Vacuum mixing two packs of cement per syringe was more effective than one pack per syringe, and all three systems significantly increased the cycles to failure of Simplex P over the control cement. However, the Enhancement and Mitab vacuum mixing systems still produced some very weak specimens in fatigue. Two packs of cement per syringe prepared in the Mixevac II vacuum mixing system were significantly stronger in fatigue than two packs mixed in either the Enhancement or Mitab vacuum system. The Mixevac II vacuum mixing system was the most effective technique of the three vacuum mixing systems tested. Centrifugation of one or two packs of Simplex P per syringe produced a more uniform cement that was free of large voids and thus eliminated the very weak specimens.(ABSTRACT TRUNCATED AT 250 WORDS)
STUDY DESIGN: Retrospective cohort. OBJECTIVES: To compare the prevalence of the association between contiguous intervertebral disc and vertebral collapses with or without an intravertebral vacuum phenomenon. SUMMARY OF BACKGROUND DATA: The mechanism of occasional gas accumulation within some vertebral collapses is poorly known. The current hypothesis is that this phenomenon is indicative of bone ischemia. In fact, avascular necrosis as the main pathologic event remains speculative, and should not explain per se the presence of gas within a vertebral body. METHODS: Comparison of the prevalence of intervertebral disc vacuum phenomenon adjacent to the affected vertebral body in 23 cases of intravertebral vacuum phenomenon in 19 patients (intravertebral vacuum phenomenon group) and in 708 osteoporotic collapses without intravertebral vacuum phenomenon in 199 patients (control group). RESULTS: There were no differences in sex and age between the two groups, and all the patients in the intravertebral vacuum phenomenon group had signs of underlying osteoporosis. A vacuum phenomenon in at least one intervertebral disc adjacent to the collapses on radiographs, conventional tomography, computed tomography, or magnetic resonance imaging was found in 19 cases (83%) in the intravertebral vacuum phenomenon group, compared with 13% in the control group (P < 0.0001). Considering plain radiographs only, this association was found in 50% of the intravertebral vacuum phenomenon group and in 9.7% of the control group (P < 0.0001). The intervertebral and intravertebral gaseous collections were connected through a fractured endplate in six cases. CONCLUSIONS: The high prevalence of the association of contiguous intervertebral and intravertebral vacuum phenomenon could have implications in the pathogenesis of the intravertebral vacuum phenomenon. We hypothesize that the intravertebral vacuum phenomenon could simply be the result of migration of an intradiscal-gaseous collection through the fractured endplate of some osteoporotic collapses.
BACKGROUND: High-efficiency particulate-arrest-filter vacuum cleaners are recommended to allergy sufferers although their use increases personal cat allergen exposure. We aimed to measure personal mite allergen exposure during vacuum cleaning by nasal air sampling and to compare exposures while vacuuming and emptying the vacuum cleaner bag. METHODS: Five brand new high-efficiency vacuum cleaners were selected. An old, previously used vacuum cleaner with its original microfilter in situ was used as a control. Nasal air samples were taken prior to and during vacuum cleaning in 10 homes. Samples were processed by HALOgen assay. Personal mite and cat allergen exposure was measured as the dust compartments were emptied. RESULTS: There was an increase in personal mite allergen exposure with vacuum cleaning, which approached significance (P = 0.058). There was no difference between the high-efficiency vacuum cleaners and the control vacuum cleaner (P = 0.141). When the dust compartments were emptied, personal mite and cat allergen exposure increased (P < 0.02). CONCLUSIONS. The increase in personal mite allergen exposure while vacuum cleaning in an area with mild to moderate mite allergen exposure is small. High-efficiency vacuum cleaners confer no benefit and cannot currently be recommended to allergy sufferers as a means of reducing personal mite allergen exposure.
OBJECTIVE: We investigated the success rate of operative vaginal delivery and risk of rectal sphincter injury when forceps or vacuum was used. STUDY DESIGN: Cases were identified by a retrospective review of delivery logbooks and an obstetric database. Rotations were excluded. Failure was defined as inability to deliver the fetus with the initial instrument. Rectal injury was defined as third- or fourth-degree laceration. Institutional review board approval was obtained. P-value of less than .05 was considered significant, and odds ratios (OR) were calculated when appropriate. RESULTS: Data were obtained for 1802 deliveries: 1438 occiput anterior and 364 occiput posterior positions. For occiput anterior position, rectal sphincter injury with forceps was 53.8% and vacuum 26.6% (P < .0001, OR 3.25). Failure rate with vacuum was 6.3% and forceps 0.9% (P < .0001, OR 7.53). For occiput posterior position, rectal injury with forceps was 71.6% and vacuum 33.1% (P < .0001; OR 5.25). Failure rate with vacuum was 33.0% and with forceps 13.6% (P < .0001, OR 3.15). For occiput posterior position, failure rate at mid position with vacuum was 71.4%, and forceps 16.7% (P < .001, OR 12.5). Failure rate at low position with vacuum was 30.8%, and forceps 12.5% (P < .001, OR 3.14). Failure rate with vacuum at mid position was higher than at low position (P < .0001, OR 5.57). Failure rate with forceps at mid and low positions was not significantly different. There was no difference in failure rate between vacuum and forceps at the outlet position. CONCLUSIONS: For both occiput anterior and posterior cases, the use of forceps was associated with a higher success rate than the vacuum, but with greater risk of rectal sphincter injury. The use of either vacuum or forceps from the occiput posterior position was associated with a higher likelihood of rectal injury and lower likelihood of vaginal delivery when compared with the occiput anterior position.
BACKGROUND: On the basis of experimental chamber studies, vacuum cleaners with double-thickness bags and integral high-efficiency particulate arrest (HEPA) air filters are claimed to reduce airborne allergen levels and are currently recommended to allergic patients. OBJECTIVES: The objective of this study was to investigate the effect of vacuum cleaning on personal inhaled cat allergen exposure in homes with cats. METHODS: Five unused new vacuum cleaners were compared with an old non-HEPA filter vacuum cleaner. Each vacuum cleaner was tested in an experimental chamber and in 5 homes with cats. Inhaled cat allergen was measured by nasal air sampling. RESULTS: New vacuum cleaners failed to leak any allergen in the experimental chamber. There was a significant increase in inhaled cat allergen during vacuum cleaning in homes (F = 48.39, df = 1.4, P =.002) with no difference between the old vacuum cleaner and the unused new vacuum cleaners (5-fold and 3-fold increase compared to baseline, respectively; F = 0.005, df = 1.4, P =.95). CONCLUSIONS: The use of new HEPA-filter vacuum cleaners increases inhaled cat allergen in homes with cats. The use of HEPA-filter modern vacuum cleaners to reduce pet allergen exposure in the homes of pet owners should not be justified merely on the basis of experimental chamber data.
OBJECTIVE: To evaluate obstetric risk factors associated with a failed trial of vacuum extraction and to assess its pregnancy outcome. STUDY DESIGN: All attempted vacuum extractions between the years 1990 and 1998 were identified, and a comparison of successful and failed trials of vacuum extraction in singleton, vertex deliveries was performed. RESULTS: Of 2,111 trials of vacuum extraction, 113 (5.4%) cases were complicated by failed extraction and underwent cesarean section. Those neonates were significantly more likely to be large for gestational age, specifically to weigh > 4,000 g as compared to the controls. Patients lacking prenatal care had significantly higher rates of failed vacuum extraction trials. While cervical and uterine tears were rather rare, parturients who had failed trials of vacuum extraction had significantly higher rates of cervical and uterine tears as compared to those with successful vacuum extractions. This association remained significant after controlling for a previous cesarean section using the Mantel-Hanszel technique. Women from the failed vacuum extraction group had significantly higher rates of postpartum anemia. Pregnancies complicated by failed vacuum extraction had significantly higher rates of intrapartum and postpartum fetal death. Those neonates had significantly higher rates of Apgar scores < 7 at one and five minutes. CONCLUSION: Failed trial of vacuum extraction is associated with adverse maternal and fetal outcomes. Risk factors associated with such failures are fetal weight and lack of prenatal care. Thus, careful estimation of fetal weight should be performed before the procedure, and estimated fetal weight > 4,000 g might be considered a relative contraindication to vacuum extraction, especially among patients who did not have prenatal care.
The issue of fine particle (PM2.5) exposures and their potential health effects is a focus of scientific research because of the recently promulgated National Ambient Air Quality Standard for PM2.5. Before final implementation, the health and exposure basis for the standard will be reviewed by the U.S. Environmental Protection Agency within the next five years. As part of this process, it is necessary to understand total particle exposure issues and to determine the relative importance of the origin of PM2.5 exposure in various micro-environments. The results presented in this study examine emissions of fine particles from a previously uncharacterized indoor source: the residential vacuum cleaner. Eleven standard vacuum cleaners were tested for the emission rate of fine particles by their individual motors and for their efficiency in collecting laboratory-generated fine particles. An aerosol generator was used to introduce fine potassium chloride (KCl) particles into the vacuum cleaner inlet for the collection efficiency tests. Measurements of the motor emissions, which include carbon, and the KCl aerosol were made using a continuous HIAC/Royco 5130 A light-scattering particle detector. All tests were conducted in a metal chamber specifically designed to completely contain the vacuum cleaner and operate it in a stationary position. For the tested vacuum cleaners, fine particle motor emissions ranged from 9.6 x 10(4) to 3.34 x 10(8) particles/min, which were estimated to be 0.028 to 176 micrograms/min for mass emissions, respectively. The vast majority of particles released were in the range of 0.3-0.5 micron in diameter. The lowest particle emission rate was obtained for a vacuum cleaner that had a high efficiency (HEPA) filter placed after the vacuum cleaner bag and the motor within a sealed exhaust system. This vacuum cleaner removed the KCl particles that escaped the vacuum cleaner bag and the particles emitted by the motor. Results obtained for the KCl collection efficiency tests show > 99% of the fine particles were captured by the two vacuum cleaners that used a HEPA filter. A series of tests conducted on two vacuum cleaners found that the motors also emitted ultra-fine particles above 0.01 micron in diameter at rates of greater than 10(8) ultra-fine particles/CF of air. The model that had the best collection efficiency for fine particles also reduced the ultra-fine particle emissions by a factor of 1 x 10(3).
OBJECTIVE: To compare assisted vaginal delivery by forceps with delivery by vacuum extractor, where a new vacuum extractor policy was employed which dictated the cup to be used in specific situations. DESIGN: Multicentre randomised controlled trial. SETTING: Four district general hospitals in the West Midlands. SUBJECTS: Six hundred-seven women requiring assisted vaginal delivery, of whom 296 were allocated to vacuum extractor delivery and 311 to forceps. MAIN OUTCOME MEASURES: Delivery success rate, maternal perineal and vaginal injuries, maternal anaesthetic requirements, neonatal scalp and facial injuries. RESULTS: Of the vacuum extractor group, 85% were delivered by the allocated instrument compared to 90% in the forceps group (odds ratio (OR) 0.64; 95% confidence intervals (CI) 0.4-1.04). However, more women in the vacuum extractor group were delivered vaginally (98%) than in the forceps group (96%). There were significantly fewer women with anal sphincter damage or upper vaginal extensions in the vacuum extractor group (11% vs 17%, OR 0.6; 95% CI, 0.38-0.97). There were significantly fewer women in the vacuum extractor group requiring epidural or spinal anaesthetics (25.4% vs 32.7%, OR 0.69; 95% CI 0.49-0.99) or general anaesthetics (1% vs 4%, OR 0.17; 95% CI 0.04-0.76). Although there were significantly more babies in the vacuum extractor group with cephalhaematomata (9% vs 3%, OR 3.3; 95% CI 1.4-7.4) there were fewer babies in the vacuum extractor group with other facial injuries. There were three babies in the forceps group with unexplained neonatal convulsions. CONCLUSIONS: Assisted vaginal delivery using the new vacuum extractor policy is associated with significantly less maternal trauma than with forceps. Further studies are required to assess neonatal morbidity adequately.
OBJECTIVE: The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. RESULTS: Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. CONCLUSION: MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.
The effect of an advanced vacuum skin packaging system on the microbiological and physicochemical properties of fresh retail cuts of beef (including meat portions from six different anatomical regions) stored at 4 degrees C was compared with the effect of traditional vacuum packaging. The vacuum skin packaging system whose effect on meat quality was evaluated in this work displayed two remarkable features: (i) the instantaneous heating of the lower surface of the upper film of the package before the film descended over the meat surface and (ii) the tight disposition of the plastic film on the meat surface, which avoided wrinkles and purges. Throughout storage at 4 degrees C, rates of bacterial growth were statistically significantly slower in beef portions processed with the vacuum skin packaging system than in those processed with traditional vacuum packaging, with average differences of 2.07, 1.60, and 1.25 log CFU/g in counts of aerobic mesophiles, anaerobes, and lactic acid bacteria, respectively. pH values were statistically significantly lower for beef portions packaged with the vacuum skin system than for those that were vacuum packaged in the traditional manner, probably because of the relative predominance of lactic acid bacteria observed in such samples, which coincided with both higher meat firmness values and a slower meat tenderization process. The vacuum skin system prevented the appearance of undesirable coloration on the meat surface and also significantly improved the commercial color of the meat as determined on the basis of luminosity (L*) and the redness (a*). Overall, the quality (as determined by microbiological and physicochemical analyses and by visual examination) of fresh retail cuts of beef packaged with the vacuum skin system and stored at 4 degrees C was higher than that of meat samples processed with the traditional vacuum-packaging system.