Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Steel”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Bactericidal activity of copper and niobium-alloyed austenitic stainless steel.

Biofouling and microbiologically influenced corrosion are processes of material deterioration that originate from the attachment of microorganisms as quickly as the material is immersed in a nonsterile environment. Stainless steels, despite their wide use in different industries and as appliances and implant materials, do not possess inherent antimicrobial properties. Changes in hygiene legislation and increased public awareness of product quality makes it necessary to devise control methods that inhibit biofilm formation or to act at an early stage of the biofouling process and provide the release of antimicrobial compounds on a sustainable basis and at effective level. These antibacterial stainless steels may find a wide range of applications in fields, such as kitchen appliances, medical equipment, home electronics, and tools and hardware. The purpose of this study was to obtain antibacterial stainless steel and thus mitigate the microbial colonization and bacterial infection. Copper is known as an antibacterial agent; in contrast, niobium has been demonstrated to improve the antimicrobial effect of copper by stimulating the formation of precipitated copper particles and its distribution in the matrix of the stainless steel. Thus, we obtained slides of 3.8% copper and 0.1% niobium alloyed stainless steel; subjected them to three different heat treatment protocols (550 degrees C, 700 degrees C, and 800 degrees C for 100, 200, 300, and 400 hours); and determined their antimicrobial activities by using different initial bacterial cell densities and suspending solutions to apply the bacteria to the stainless steels. The bacterial strain used in these experiments was Escherichia coli CCM 4517. The best antimicrobial effects were observed in the slides of stainless steel treated at 700 degrees C and 800 degrees C using an initial cell density of approximately 10(5) cells ml(-1) and phosphate-buffered saline as the solution in which the bacteria came into contact with copper and niobium-containing steel.

Alloys↗

Comparison of the thrombogenicity of stainless steel and tantalum coronary stents.

This study was designed to compare the thrombogenicity of stainless steel and tantalum coronary stents of the same design. Stainless steel and tantalum coronary stents are being evaluated for their utility in treating acute closure and restenosis. A major disadvantage of stainless steel stents is radiolucency. To determine whether radioopaque tantalum stents may be safely substituted for stainless steel stents, we compared the relative thrombogenicity of these materials in stents of identical design. Total platelet and fibrin deposition on the stents were determined from measurements of indium 111-labeled platelet and iodine 125-labeled fibrinogen accumulation after deployment into exteriorized chronic arteriovenous shunts in seven untreated baboons. In another series of experiments, 111In-platelet deposition was compared 2 hours after stent implantation in coronary arteries of pigs. In baboons, platelet thrombus formation on stainless steel and tantalum stents was equivalent and plateaued at approximately 2.5 x 10(9) platelets after 1 hour (p > 0.05). Fibrin deposition averaged approximately 1 mg/stent and did not differ between the stainless steel and tantalum stents (p > 0.05). In the porcine coronary model there was no significant difference in 111In-labeled platelet deposition between the stainless steel and tantalum stents (p > 0.05). This result was confirmed by scanning electron microscopic analysis of the coronary stents. Based on these two models, we conclude that there is no significant difference in the thrombogenicity of stainless steel and tantalum wire coil stents.

Animals↗

The effects of cold treatment on the physical properties of stainless steel and titanium alloy endodontic posts and instruments.

This study determined whether cold treatment at -96 degrees C affected the mechanical properties of different compositions and sizes of Flexi-Post systems, various sizes of dental reamers, and external wrenches. The experiment was divided into eight groups. The four control groups were untreated and consisted of (1) 50 stainless steel posts, (2) 40 titanium posts, (3) 50 stainless steel reamers, and (4) 10 stainless steel external wrenches. The four experimental groups were cold treated once and twice and included (1) 100 stainless steel posts, (2) 80 titanium posts, (3) 100 stainless steel reamers, and (4) 20 stainless steel external wrenches. The bending or breaking forces were tested on a universal testing machine. Stainless steel Flexi-Post dowels, stainless steel reamers, and external wrenches all showed a significant (ANOVA) (p < 0.05) increase in strength as a result of the single and double cold treatment. Titanium posts showed no strength increase following a single cold treatment, while they were weakened by a double cold treatment.

Analysis of Variance↗

Decomposition of energetic chemicals contaminated with iron or stainless steel.

Contamination of chemicals or reaction mixtures with iron or stainless steel is likely to take place during chemical processing. If energetic and thermally unstable chemicals are involved in a manufacturing process, contamination with iron or stainless steel can impact the decomposition characteristics of these chemicals and, subsequently, the safety of the processes, and should be investigated. The goal of this project was to undertake a systematic approach to study the impact of iron or stainless steel contamination on the decomposition characteristics of different chemical classes. Differential scanning calorimetry (DSC) was used to study the decomposition reaction by testing each chemical pure, and in mixtures with iron and stainless steel. The following classes of energetic chemicals were investigated: nitrobenzenes, tetrazoles, hydrazines, hydroxylamines and oximes, sulfonic acid derivatives and monomers. The following non-energetic groups were investigated for contributing effects: halogens, hydroxyls, amines, amides, nitriles, sulfonic acid esters, carbonyl halides and salts of hydrochloric acid. Based on the results obtained, conclusions were drawn regarding the sensitivity of the decomposition reaction to contamination with iron and stainless steel for the chemical classes listed above. It was demonstrated that the most sensitive classes are hydrazines and hydroxylamines/oximes. Contamination of these chemicals with iron or stainless steel not only destabilizes them, leading to decomposition at significantly lower temperatures, but also sometimes causes increased severity of the decomposition. The sensitivity of nitrobenzenes to contamination with iron or stainless steel depended upon the presence of other contributing groups: the presence of such groups as acid chlorides or chlorine/fluorine significantly increased the effect of contamination on decomposition characteristics of nitrobenzenes. The decomposition of sulfonic acid derivatives and tetrazoles was not impacted by presence of iron or stainless steel.

Calorimetry↗

Neuromotor function in a cohort of Danish steel workers.

OBJECTIVE: With a longitudinal design to evaluate possible neuromotor impairment in a cohort of steel workers exposed to metal dust. MATERIAL: Ninety-two employees from a steel works were examined in 1989 and 1995. Sixty were re-examined in 2003. A non-matched control group was examined in 1996 (n=19) and in 2003 (n=14). Median blood manganese in 1989, 1995 and 2003 was 149, 171 and 155 nmol/l. Median blood lead in 1989 and 2003 was 0.76 and 0.22 micromol/l. Median air concentration of manganese at the steel works was estimated to be 0.11 mg/m3 in 1970s and was 0.03 mg/m3 in 1990s. Median air concentration of lead was estimated to be 0.13 mg/m3 in 1970s and was 0.01 mg/m3 in 1990s. METHOD: The Catsys 2000 system developed by Danish Product Development is computer-based device for measuring hand tremor, hand coordination and reaction time. RESULTS: Over all there were no statistically significant differences in neuromotor function between the participating steel workers, non-participating steel workers and controls in 1995/1996. Only reaction time for the right hand was slower for the participating steel workers. Compared with the control group the steel workers showed a decline in the ability to perform fast precise hand pronation/supination and finger tapping from 1995 to 2005. Correlation analysis showed no associations between test results for fast hand coordination and blood manganese and lead. Only seniority was associated with deterioration of beat regulation of fast pronation/supination of the hands. DISCUSSION: On a group basis the changes were subclinical, but they should none the less be taken seriously. CONCLUSION: Changes of neuromotor function measured as the ability to perform fast precise pronation/supination of the hands and fast precise finger tapping was shown in this cohort of steel workers. No causal relationships could be shown.

Adult↗

Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?

BACKGROUND CONTEXT: Surgeons are hesitant to mix components made of differing metal classes for fear of galvanic corrosion complications. However, in vitro studies have failed to show a significant potential for galvanic corrosion between titanium and stainless steel, the two primary metallic alloys used for spinal implants. Galvanic corrosion resulting from metal mixing has not been described in the literature for spinal implant systems. PURPOSE: To determine whether galvanic potential significantly affects in vitro corrosion of titanium and stainless steel spinal implant components during cyclical compression bending. STUDY DESIGN/SETTING: Bilateral spinal implant constructs consisting of pedicle screws, slotted connectors, 6.35-mm diameter rods and a transverse rod connector assembled in polyethylene test blocks were tested in vitro. Two constructs had stainless steel rods with mixed stainless steel (SS-SS) and titanium (SS-Ti) components, and two constructs had titanium rods with mixed stainless steel (Ti-SS) and titanium (Ti-Ti) components. METHODS: Each construct was immersed in phosphate-buffered saline (pH 7.4) at 37 C and tested in cyclic compression bending using a sinusoidal load-controlling function with a peak load of 300 N and a frequency of 5 Hz until a level of 5 million cycles was reached. The samples were then removed and analyzed visually for evidence of corrosion. In addition, scanning electron microscopy (SEM) and energy dispersive spectrometry (EDS) were used to evaluate the extent of corrosion at the interconnections. RESULTS: None of the constructs failed during testing. Gross observation of the implant components after disassembly revealed that no corrosion had occurred on the surface of the implants that had not been in contact with another component. The Ti-Ti interfaces showed some minor signs of corrosion only detectable using SEM and EDS. The greatest amount of corrosion occurred at the SS-SS interfaces and was qualitatively less at the SS-Ti and Ti-SS interfaces. CONCLUSIONS: The results from this study indicate that when loaded dynamically in saline, stainless steel implant components have a greater susceptibility to corrosion than titanium. Furthermore, the galvanic potential between the dissimilar metals does not cause a discernible effect on the corrosion of either. Although the mixture of titanium alloy with stainless steel is not advocated, the results of this study suggest that galvanic corrosion is less pronounced in SS-Ti mixed interfaces than in all stainless steel constructs.

Alloys↗

Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations.

This study measured and compared the level of frictional resistance generated between stainless steel self-ligating brackets (Damon SL II, SDS Ormco, Glendora, Calif), polycarbonate self-ligating brackets (Oyster, Gestenco International, Göthenburg, Sweden), and conventional stainless steel brackets (Victory Series, 3M Unitek, Monrovia, Calif), and 3 different orthodontic wire alloys: stainless steel (Stainless Steel, SDS Ormco), nickel-titanium (Ni-Ti, SDS Ormco), and beta-titanium (TMA, SDS Ormco). All brackets had a.022-in slot, whereas the orthodontic wire alloys were tested in 3 different sections:.016,.017 x.025, and.019 x 0.025 in. Each of the 27 bracket and archwire combinations was tested 10 times, and each test was performed with a new bracket-wire sample. Both static and kinetic friction were measured on a custom-designed apparatus. All data were statistically analyzed (Kruskal-Wallis and Mann Whitney U tests). Stainless steel self-ligating brackets generated significantly lower static and kinetic frictional forces than both conventional stainless steel and polycarbonate self-ligating brackets, which showed no significant differences between them. Beta-titanium archwires had higher frictional resistances than stainless steel and nickel-titanium archwires. No significant differences were found between stainless steel and nickel-titanium archwires. All brackets showed higher static and kinetic frictional forces as the wire size increased.

Dental Alloys↗

Coefficients of friction for arch wires in stainless steel and polycrystalline alumina bracket slots. I. The dry state.

The surface roughness and the coefficients of friction were measured for sixteen arch wire-bracket combinations. The sample included one rectangular arch wire product from each of the four principal alloy groups and one bracket product from among the stainless steel and polycrystalline alumina inventory. Although subsamples representing both the 0.018-inch and the 0.022-inch slot sizes were evaluated, no differences were observed in their rankings. When tested over a series of eight incident angles, the optical surface roughness of representative stainless steel and alumina brackets averaged 0.148 and 0.193 microns, respectively. After testing at a single angle (82 degree) and referencing a nomogram, the roughness of the stainless steel, cobalt-chromium, beta-titanium, and nickel-titanium arch wire surfaces averaged 0.053, 0.129, 0.137, and 0.247 microns, respectively. When the various arch wire-bracket couples were pressed against an 0.010-inch stainless steel ligature wire at 34 degrees C and otherwise prevailing atmospheric conditions, the coefficients of friction ranged from stainless steel (lowest) to cobalt-chromium, nickel-titanium, and beta-titanium (highest)--regardless of bracket product or slot size. These results corroborated earlier observations in which the same arch wire products were drawn between stainless steel or alumina contact flats. In the current research, the average coefficient of kinetic friction for the stainless steel couple (0.139) was less than that for the stainless steel arch wire against a polycrystalline alumina bracket (0.174).

Aluminum Oxide↗

Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants.

STUDY DESIGN: This was a prospective in vitro study comparing titanium alloy and stainless steel alloy in transpedicular spine implants from two different manufactures. OBJECTIVE: To compare the multicycle mechanical performance of these two alloys, used in each of two different implant designs. SUMMARY OF BACKGROUND DATA: Transpedicular spine implants primarily have been manufactured from stainless steel, but titanium alloy offers imaging advantages. However, the notch sensitivity of titanium alloy has caused concern regarding how implants made from this material will compare in stiffness and fatigue life with implants made from stainless steel. METHODS: Twenty-four implants (two alloys, two designs, six implants per group) were mounted in machined polyethylene wafers and repetitively loaded (up to 1 million cycles) from 80 N to 800 N using a 5-Hertz sinusoidal waveform. Load and displacement data were automatically and periodically sampled throughout the entire test. RESULTS: Implant stiffness increased with cycle load number, reached a steady state, then declined just before fatigue failure. Stiffness varied less in titanium transpedicular spine implants than in their stainless counterparts. All stainless steel implant types were stiffer (steady-state value, P < 0.0001) than their titanium alloy counterparts. One titanium implant design failed with fewer (P < 0.05) load cycles than its stainless steel counterpart, whereas a stainless steel implant of another design failed with fewer (P < 0.002) load cycles than its titanium counterpart. Overall, fatigue life, i.e., the total number of load cycles until failure, was related to implant type (P < 0.0001), but not to implant material. CONCLUSIONS: A transpedicular spine implant's fatigue lifetime depends on both the design and the material and cannot be judged on material alone. Stainless steel implants are stiffer than titanium alloy implants of equal design and size; however, for those designs in which the fatigue life of the titanium alloy version is superior, enlargement of the implant's components can compensate for titanium's lower modulus of elasticity and result in an implant equally stiff as its stainless steel counterpart. Such an implant made from titanium alloy would then be clinically preferable because of titanium's previously reported imaging advantages.

Elasticity↗

Nickel release from nickel-plated metals and stainless steels.

Nickel release from nickel-plated metals often induces allergic contact dermatitis, but, for nickel-containing stainless steels, the effect is not well-known. In this paper, AISI 304, 316L, 303 and 430 type stainless steels, nickel and nickel-plated materials were investigated. 4 tests were performed: patch tests, leaching experiments, dimethylglyoxime (DMG) spot tests and electrochemical tests. Patch tests showed that 96% of the patients were intolerant to Ni-plated samples, and 14% to a high-sulfur stainless steel (303), while nickel-containing stainless steels with a low sulfur content elicited no reactions. Leaching experiments confirmed the patch tests: in acidic artificial sweat, Ni-plated samples released about 100 micrograms/cm2/week of nickel, while low-sulfur stainless steels released less than 0.03 microgram/cm2/week of nickel, and AISI 303 about 1.5 micrograms/cm2/week. Attention is drawn to the irrelevance of the DMG spot test, which reveals Ni present in the metal bulk but not its dissolution rate. Electrochemical experiments showed that 304 and 316 grades remain passive in the environments tested, while Ni-plated steels and AISI 303 can suffer significant cation dissolution. Thus, Ni-containing 304 and 316 steels should not induce contact dermatitis, while 303 should be avoided. A reliable nitric acid spot test is proposed to distinguish this grade from other stainless steels.

Chemistry Techniques, Analytical↗

Corrosion characteristics of ferric and austenitic stainless steels for dental magnetic attachment.

The corrosion behaviors of four ferric stainless steels and two austenitic stainless steels were examined in a simulated physiological environment (0.9% NaCl solution) to obtain basic data for evaluating the appropriate composition of stainless steels for dental magnetic attachments. The corrosion resistance was evaluated by electrochemical techniques and the analysis of released metal ions by atomic absorption spectrophotometry. The surface of the stainless steels was analyzed by X-ray photoelectron spectroscopy (XPS). The breakdown potential of ferric stainless steels increased and the total amount of released metal ions decreased linearly with increases in the sum of the Cr and Mo contents. The corrosion rate of the ferric stainless steels increased 2 to 6 times when they were galvanically coupled with noble metal alloys but decreased when coupled with commercially pure Ti. For austenitic stainless steels, the breakdown potential of high N-bearing stainless steel was approximately 500 mV higher than that of SUS316L, which is currently used as a component in dental magnetic attachments. The enriched nitrogen at the alloy/passive film interface may be effective in improving the localized corrosion resistance.

Carbon↗

Myeloid cell proliferation stimulated by Steel factor is pertussis toxin sensitive and enhanced by cholera toxin.

Effects of G-protein toxins on Steel factor (SLF) and granulocyte-macrophage colony stimulating factor (GM-CSF) stimulated proliferation of human factor-dependent cell line, M07e, were evaluated. Pertussis toxin pretreatment suppressed GM-CSF- or Steel factor-induced proliferation by 54 +/- 8%; however, proliferation induced by the combination of GM-CSF plus Steel factor was suppressed to a much lesser extent (14 +/- 8%). Pretreatment of M07e cells with cholera toxin, suppressed GM-CSF- and GM-CSF plus Steel factor-stimulated proliferation by 57 +/- 6% and 79%, respectively, but increased the proliferative response to Steel factor alone by twofold. Similar effects of pertussis toxin and cholera toxin were observed on proliferation of normal myeloid progenitor cells from human umbilical cord blood. Pertussis toxin treatment of M07e cells for 4 h resulted in the ADP-ribosylation of 40-42 kDa protein band but did not significantly increase cyclic AMP levels. Cholera toxin pretreatment was associated with a 10-fold increase in intracellular cyclic AMP levels. These results implicate pertussis toxin sensitive pathways for both GM-CSF and Steel factor, but suggest that these pathways may not be required for synergistic proliferation stimulated by the combination. In addition, proliferation stimulated by GM-CSF, +/- Steel factor, is sensitive to cholera toxin pretreatment; whereas cholera toxin pretreatment enhanced proliferation stimulated by Steel factor, possibly via increased cyclic AMP. This suggests divergent signal transduction pathways for the two cytokines.

Adenylyl Cyclases↗

Steel factor and c-kit regulate cell-matrix adhesion.

Steel (SI) and white spotting (W) loci encode steel factor (c-kit ligand) and the c-kit tyrosine kinase receptor, respectively. Mutations at these loci affect migration and differentiation of primordial germ cells, neural crest-derived melanoblasts, and hematopoietic cells. In these processes, cell adhesion molecules are hypothesized to be crucial. We have examined the role of steel factor and c-kit in cell-extracellular matrix adhesion using bone marrow-derived mast cells as a model system. Steel factor stimulates mast cells to bind to fibronectin and, to a lesser extent, to vitronectin, whereas interleukin-3 and interleukin-4, which are also mast cell growth factors, do not. Activation of adhesiveness is transient, occurs at concentrations of steel factor 100-fold lower than required for growth stimulation, and requires the integrin VLA-5. Mast cells from c-kit mutant mice adhere to fibronectin on stimulation with phorbol 12-myristate 13-acetate (PMA), but not on stimulation with steel factor, indicating that stimulation of integrin adhesiveness requires activation of the c-kit protein tyrosine kinase. By contrast, c-kit mutant and wild-type mast cells adhere equally well to COS cells expressing membrane-anchored steel factor, showing that the kinase activity of c-kit is not required for adhesion directly mediated by c-kit. Our findings suggest that regulation of adhesion is an important biologic function of steel factor.

Animals↗

Duplex stainless steels for osteosynthesis devices.

The austenitic stainless steels used today for the manufacture of osteosynthesis devices are sensitive to crevice corrosion. In this study the corrosion properties of some duplex stainless steels were evaluated and compared to traditional austenitic stainless steels. According to our results the following ranking was established: 23Cr-4Ni less than AISI 316L less than ASTM F138 less than 22Cr-5Ni-3Mo less than 27Cr-31Ni-3.5Mo less than 25Cr-7Ni-4Mo-N. In particular the results showed that the high-performance 25Cr-7Ni-4Mo-N duplex stainless steel, with high molybdenum and nitrogen contents, can be considered not susceptible to crevice corrosion in the human body. The duplex stainless steels have also better mechanical properties at the same degree of cold working compared with austenitic stainless steels. Hence the 25Cr-7Ni-4Mo-N duplex stainless steel can be considered a convenient substitute of ASTM F138 for orthopedic and osteosynthesis devices.

Biocompatible Materials↗

Fracture toughness of steel-fiber-reinforced bone cement.

Fractures in the bone-cement mantle (polymethyl methacrylate) have been linked to the failure of cemented total joint prostheses. The heat generated by the curing bone cement has also been implicated in the necrosis of surrounding bone tissue, leading to loosening of the implants. The addition of reinforcements may improve the fracture properties of bone cement and decrease the peak temperatures during curing. This study investigates the changes in the fracture properties and the temperatures generated in the ASTM F451 tests by the addition of 316L stainless steel fibers to bone cement. The influence of filler volume fraction (5-15% by volume) and aspect ratios (19, 46, 57) on the fracture toughness of the acrylic bone cement was assessed. Increasing the volume fraction of the steel fibers resulted in significant increases in the fracture toughness of the steel-fiber-reinforced composite. Fracture-toughness increases of up to 2.63 times the control values were obtained with the use of steel-fiber reinforcements. No clear trend in the fracture toughness was discerned for increasing aspect ratios of the reinforcements. There is a decrease in the peak temperatures reached during the curing of the steel-fiber-reinforced bone cement, though the decrease is too small to be clinically relevant. Large increases in the fatigue life of acrylic bone cement were also obtained by the addition of steel fibers. These results indicate that the use of steel fibers may enhance the durability of cemented joint prostheses.

Biocompatible Materials↗

Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates.

INTRODUCTION: Stainless steel and commercially pure titanium are widely used materials in orthopedic implants. However, it is still being controversially discussed whether there are significant differences in tissue reaction and metallic release, which should result in a recommendation for preferred use in clinical practice. MATERIALS AND METHODS: A comparative study was performed using 14 stainless steel and 8 commercially pure titanium plates retrieved after a 12-month implantation period. To avoid contamination of the tissue with the elements under investigation, surgical instruments made of zirconium dioxide were used. The tissue samples were analyzed histologically and by inductively coupled plasma atomic emission spectrometry (ICP-AES) for accumulation of the metals Fe, Cr, Mo, Ni, and Ti in the local tissues. Implant corrosion was determined by the use of scanning electron microscopy (SEM). RESULTS: With grades 2 or higher in 9 implants, steel plates revealed a higher extent of corrosion in the SEM compared with titanium, where only one implant showed corrosion grade 2. Metal uptake of all measured ions (Fe, Cr, Mo, Ni) was significantly increased after stainless steel implantation, whereas titanium revealed only high concentrations for Ti. For the two implant materials, a different distribution of the accumulated metals was found by histological examination. Whereas specimens after steel implantation revealed a diffuse siderosis of connective tissue cells, those after titanium exhibited occasionally a focal siderosis due to implantation-associated bleeding. Neither titanium- nor stainless steel-loaded tissues revealed any signs of foreign-body reaction. CONCLUSION: We conclude from the increased release of toxic, allergic, and potentially carcinogenic ions adjacent to stainless steel that commercially pure Ti should be treated as the preferred material for osteosyntheses if a removal of the implant is not intended. However, neither material provoked a foreign-body reaction in the local tissues, thus cpTi cannot be recommend as the 'golden standard' for osteosynthesis material in general.

Adipose Tissue↗

Shear-flow induced detachment of Saccharomyces cerevisiae from stainless steel: influence of yeast and solid surface properties.

The present study focused on the shear-induced detachment of Saccharomyces cerevisiae in adhesive contact with a 316L stainless steel surface using a shear stress flow chamber, with a view to determining the respective influence of the yeast surface properties and the support characteristics. The effect of cultivation of S. cerevisiae yeast cells on their subsequent detachment from the solid surface was particularly investigated. In order to elucidate the role of stainless steel, non-metallic supports were used as control, covering a broad range of surface properties such as surface free energy and roughness: polypropylene (hydrophobic), polystyrene (mildly hydrophobic, similar to stainless steel) and glass (hydrophilic). All materials were very smooth with respect to the size of yeast. First, experiments were carried out on two types of yeast cells, just rehydrated in saline solution, a biological model widely used in the literature. The influence of the ionic strength (1.5 and 150 mM NaCl) on glass and stainless steel was evaluated. Unlike on glass, no clear evidence was found for electrostatic repulsion with stainless steel since high adhesion was observed whatever the ionic strength. A lack of correlation in adhesion results was also obtained when considering the surface physico-chemical characteristics of type I (hydrophilic) and type II (hydrophobic) rehydrated cells and those of both polymers. It was postulated that unavoidable "sticky" compounds were present on the cell wall, which could not be completely removed during the successive washings of the rehydrated cell suspension before use. This could dramatically alter the yeast surface properties and modify the adhesion strength, thus clearly demonstrating the necessity to work with yeast coming from fresh cultures. Biologically active yeast cells were then used. Once cultured, type I- and type II-yeast cells were shown to exhibit the same hydrophilic properties. Regardless of the material used, for the same ionic strength (150 mM NaCl), yeast adhesion was drastically reduced compared to rehydrated yeast cells. Among all the materials tested, the specificity of 316L stainless steel was clearly established. Indeed, for glass and polymers, cell adhesion was substratum-dependent and driven by the balance between the Lifshitz-van der Waals and Lewis acid/base interactions. Despite nearly identical surface free energies for polystyrene and stainless steel, the metallic surface promoted a totally distinct behaviour which was characterized by a strong - although highly variable - yeast adhesion.

Cell Adhesion↗

Adsorption on stainless steel surfaces of biosurfactants produced by gram-negative and gram-positive bacteria: consequence on the bioadhesive behavior of Listeria monocytogenes.

The ability of adsorbed biosurfactants (Pf and Lb) obtained from gram-negative bacterium (Pseudomonas fluorescens) or gram-positive bacterium (Lactobacillus helveticus) to inhibit adhesion of four listerial strains to stainless steel was investigated. These metallic surfaces were characterized using the following complementary analytical techniques: contact-angle measurements (CAM), atomic force microscopy (AFM), polarization modulation-infrared reflection-adsorption spectroscopy (PM-IRRAS) and X-ray photoelectron spectroscopy (XPS). Contact-angles with polar liquids (water and formamide) indicated that the stainless steel surface covered with adsorbed biosurfactant was more hydrophilic and electron-donating than bare stainless steel. The surface characterization by XPS and PM-IRRAS revealed that conditioning the stainless steel changes the substrate in two ways, by modifying the surface alloy composition and by leaving an thin adsorbed organic layer. AFM observations enabled to say that the layer covered entirely the surface and was probably thicker (with patches) in the case of Pf-conditioned surfaces compared to the Lb-conditioned ones, which seemed to be less homogeneous. Though the added layer was thin, significant chemical changes were observed that can account for drastic modifications in the surface adhesive properties. As a matter of fact, adhesion tests showed that both used biosurfactants were effective by decreasing strongly the level of contamination of stainless steel surfaces by the four strains of Listeria monocytogenes. The more important decrease concerned the CIP104794 and CIP103573 strains (>99.7%) on surface conditioned by L. helveticus biosurfactant. A less reduced phenomenon (75.2%) for the CIP103574 strain on stainless steel with absorbed biosurfactant from P. fluorescens was observed. Whatever the strain of L. monocytogenes and the biosurfactant used, this antiadhesive biologic coating reduced both total adhering flora and viable and cultivable adherent bacteria on stainless steel surfaces. This study confirms that biosurfactants constitute an effective strategy to prevent microbial colonization of metallic surfaces by pathogenic bacteria like the food-borne pathogen L. monocytogenes.

Adsorption↗