Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RECTUM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Quantification of local rectal wall displacements by virtual rectum unfolding.

BACKGROUND AND PURPOSE: To develop a method to project surface elements of a bent tubular organ, e.g. the rectum, in order to create a two-dimensional (2D) map and to use this method to quantify on a local scale shape and position variations of the rectum. PATIENTS AND METHODS: For this study we used data of 19 patients, who each received a planning CT scan and 9-13 repeat CT scans that were considered representative for the radiotherapy course. We combined maps from multiple CT scans of the same patient to quantify local rectal wall displacements. To make a map we first computed a central axis through the rectum and divided it into segments of equal length assuming that the length of these segments was invariant under rectum shape and position changes. Next, we constructed for each segment a planar cross section through the rectum, which was oriented orthogonally to that segment. The amount of rectal wall tissue was assumed to be constant in all orthogonal cross sections throughout the entire rectum. We unfolded the cross-sected rectal wall at the dorsal side and projected either the associated dose or the coordinates onto the map. RESULTS: The largest variation in the position of the rectal wall during the treatment course occurred at the upper anterior, left and right side (1 SD=5-7 mm). Near the anus the variation was <3 mm (1 SD) and at the posterior side of the rectum <4 mm (1 SD). The anterior-posterior (AP) and left-right displacements between the rectum in the planning CT scan and the mean rectum shape during the treatment were localized between 40 and 80% of the central axis. At the upper anterior, left, and right side the displacements were 5-8 mm (1 SD). These rectal wall displacements correlated with the rectum volume in the planning CT scan. At the upper anterior side the correlation coefficient between the AP displacements and the planning rectum volume was 0.85. CONCLUSIONS: We quantified variations in rectum shape and in dose in the rectal wall. The systematic error in rectal wall position was found to be larger than the random shape and position variations. We successfully developed a method to virtually unfold a rectum and to project the dose onto a 2D map. The spatial information of the dose distribution can be used in the analysis of rectum complications.

Humans↗

A cylindrical model of the rectum: comparing dose-volume, dose-surface and dose-wall histograms in the radiotherapy of prostate cancer.

The calculation of the percentage cumulative histogram of the rectal wall (DWH) in prostate cancer radiotherapy may be subject to large uncertainties due to the difficulty of assessing the wall thickness on CT images. For this reason often only the external contour is used to define the rectum and then the percentage cumulative dose-volume histogram (DVH) of the rectum including any filling is calculated as a 'surrogate' for the DWH. More recently, other approaches using only the external contour have been proposed to estimate the DWH such as the percentage normalized dose-surface histograms (NDSH). A similar concept can be used when considering the solid rectum (the percentage normalized DVH, NDVH). The purpose of this investigation was to assess the relationships between rectal DVH, NDVH, DSH, NDSH and DWH in the common case of three- and four-field techniques in prostate cancer irradiation. Analytical relationships between the above parameters have been derived for a cylindrical rectum model in the case of three- and four-field techniques. The model is applied to the case of an empty rectum, a full rectum and to the more realistic mixed full/empty rectum situation for a four-field technique delivering 76 Gy (ICRU dose) with 18 MV x-rays. Different positions of the lateral beam with respect to the rectum axis were simulated. In the case of no lumen variation along the z-axis, the DWH is found to be very close to the DVH and to the DSH for empty and full rectum, respectively. The largest differences (up to 15%) between DVH and DSH were seen in the high-dose region (>70 Gy). In the more realistic case of lumen variation along the z-axis, the DWH always lies between NDVH and NDSH and, excluding the full-rectum situation, the DWH differs from the DVH by less than 7% in the 50-75 Gy range. In the case of significant portions of rectum being completely shielded, the DVH may differ from the NDVH/NDSH/DWH by up to 10-15%. In most clinical situations NDVH is within a few per cent of DWH, whilst NDSH may differ from DWH by up to 15-20%, especially in the high-dose region (V70). In conclusion, for most situations, the DVH is highly correlated with NDVH and DWH. A high degree of consistency between NDVH and DWH was found in most clinical cases whilst largest deviations between NDSH and DWH were evident in the high-dose region (70-75 Gy). In the less common case of a very full rectum a poorer correlation between DVH/NDVH and DWH was found whilst NDSH mimicked the DWH very well. In summary, except for the case of a 'very full' rectum, NDVH may be used as a robust surrogate for DWH. The DVH seems to be sufficiently robust if the rectum is prevalently empty.

Algorithms↗

The use of a dedicated rectosigmoidoscope for ultrasound staging of tumours of the upper and middle third of the rectum.

OBJECTIVE: Tumours of the upper rectum, and many in the middle third, are not accessible to endorectal ultrasound staging because of the difficulty in reaching all sites of the rectum with a rigid probe. The aim of this prospective study was to assess whether using a dedicated rectosigmoidoscope, endorectal ultrasonography (ERUS) can accurately stage any rectal lesion irrespective of its distance from the anal verge. METHOD: A total of 173 consecutive patients with a primary rectal tumour were included. A rotating, high multifrequency (5.0-10 MHz) endoprobe was introduced through a dedicated rectosigmoidoscope and advanced above the lesion. A computer allowed for three-dimensional (3D) reconstruction of 2D images. Treatment was selected on the basis of 3D-ERUS findings. ERUS staging was correlated with pathological staging. RESULTS: The depth of invasion was correctly determined by 3D-ERUS in 78.2% of tumours of the lower rectum, 76.4% of tumours extending between the lower and middle third of the rectum, 80.9% of tumours of the middle third of the rectum, 78.5% of tumours extending between the middle and upper third of the rectum and 78.9% of tumours of the upper rectum. The accuracy for the absence of lymph node metastases was 81.2% for tumours of the lower rectum, 78.5% for tumours extending between the lower and middle third of the rectum, 85.7% for tumours of the middle third of the rectum, 83.3% for tumours extending between the middle and upper third of the rectum and 78.5% for tumours of the upper rectum. Analysis showed that there was no difference between the various tumour sites. CONCLUSION: Our findings indicate that using a dedicated proctosigmoidoscope, tumours of the upper and middle third of the rectum are equally accessible to ultrasonographic evaluation. The distance of the tumour from the anal verge does not influence the accuracy of examinations considered adequate by the operator.

Adult↗

Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer.

PURPOSE: To determine the pattern of changes of rectum and bladder structures during conformal therapy of T3 prostate cancer and the impact of these changes on the accuracy of the dose-volume histograms (DVHs) and normal tissue complication probabilities (NTCPs) of these organs, based on the planning computed tomography (CT) scan only. METHODS AND MATERIALS: For 11 T3 prostate cancer patients treated with conformal therapy, three repeat CT scans were made in Weeks 2, 4, and 6 of the treatment. The bony anatomy was aligned with the planning CT scan, using three dimensional (3D) chamfer matching. The internal and external surfaces of rectum and bladder were contoured in each scan. Three volumes were calculated for each organ: solid organ (including filling), filling, and wall volume. DVHs and NTCPs were calculated for all structures. RESULTS: The solid organ and filling volumes varied considerably between patients and within a patient and they decreased with increasing treatment time. The largest patient variation was seen for patients with large initial filling volumes. The variations of rectum and bladder wall volumes during treatment were 9 and 17% (1 standard deviation (SD)), respectively, with no time trend. The changes of the high dose (> 80 and 90% of the prescribed dose) volumes of the rectum in response to rectum filling differences were proportional to the whole rectum volume changes. The variation of the high-dose rectum wall volume was relatively small (14%, 1 SD). As a result, the NTCPs of rectum and rectum wall were the same overall and the variation of the NTCPs during treatment was about 14% (1 SD) and not correlated with rectum filling. The variation of the high-dose bladder volumes (about 14%, 1 SD) was smaller than the variation of the whole bladder volumes (30%, 1 SD). The high-dose bladder wall volume decreased significantly due to wall distention as the bladder filling increased. As a result of this complex pattern, the variation of NTCPs of bladder (85%, 1 SD) and bladder wall (88%, 1 SD) during treatment was large and significantly correlated with bladder filling. CONCLUSIONS: The planning CT scan overestimates rectum and bladder filling during treatment. Furthermore, the variation of filling is so large that only the wall structures have relatively constant volumes during treatment. For the rectum wall, the DVHs and NTCPs, as estimated from the initial scan, are representative for the whole treatment, because no correlation was seen between these parameters and organ filling. For the bladder wall, however, such a correlation was present and consequently, the initial bladder wall DVHs and NTCPs can only be representative for the whole treatment, if the bladder filling can be kept reasonably constant during treatment.

Anthropometry↗

A study of the effect of distension of the rectosigmoid junction on the rectum and anal canal with evidence of a rectosigmoid-rectal reflex.

PURPOSE: To elucidate the role of the rectosigmoid junction (RSJ) in the mechanism of defecation. METHOD: Fourteen healthy volunteers were enrolled in the study (10 men, 4 women; mean age 38.2 +/- 10.6 years). The pressures in the rectum, anal canal, and RSJ as well as rectal balloon expulsion were recorded in response to balloon distension of the RSJ in increments of 10 ml of carbon dioxide (CO2) to 50 ml. The experiments were repeated after individual anesthetization of the RSJ, rectum, and anal canal. The expulsion of a 50-ml distended balloon located in the anesthetized rectum was tested. RESULTS: RSJ distension with 10 ml of CO2 produced no significant pressure changes in the RSJ, rectum, or anal canal. A 20-ml distension effected a significant pressure rise in the RSJ (P < 0.05) and the rectum (P < 0.01) and a decline in the anal canal (P < 0.05); the rectal balloon was expelled to the exterior. Similar pressure changes (P > 0.05) were recorded with a 30-, 40-, and 50-ml balloon distension. The mean latency for the RSJ response was 12.6 +/- 2.2 ms and for the rectum 15.8 +/- 2.6 ms. The balloon, distended with 50 ml of CO2 and located in the rectum, was not expelled to the exterior. Balloon expulsion occurred only with distension with volumes of above 80 ml. Individual anesthetization of the RSJ, rectum, and anal canal followed by RSJ distension produced no significant pressure changes in RSJ, rectum, and anal canal as well as no rectal balloon expulsion. CONCLUSION: The rectal contraction upon RSJ distension affirms the hypothesis of the possible involvement of a reflex, which we term "rectosigmoid-rectal reflex." This reflex relationship is evidenced by reproducibility and its absence on anesthetization of either the RSJ or the rectum, both presumably representing the two arms of the reflex arc. It is postulated that stools passing from the sigmoid colon to the rectum distend the RSJ and evoke the rectosigmoid-rectal reflex, which produces rectal contraction. The role of the reflex in defecation disorders needs to be studied.

Adolescent↗

On the use of margins for geometrical uncertainties around the rectum in radiotherapy planning.

BACKGROUND AND PURPOSE: To derive planning organ at risk volume (PRV) margins for the rectum and to analyse the impact of such margins on rectum dose volume histograms (DVHs). PATIENTS AND METHODS: Weekly repeat computer tomography (CT) scans of 19 bladder cancer patients acquired during a conformal radiotherapy course were registered with the corresponding planning CT scans. From these scans, the internal rectal motion was quantified, and the margins that had to be added to the rectum contour in the planning scan to encompass the observed span of rectum motion were determined. These margins were compared to the margins derived using a recent PRV margin recipe. To illustrate the impact of margins on rectum DVHs, the margins were applied in treatment plans of six prostate cancer patients. RESULTS: Altogether 141 CT scans were analysed. On average 24% of the repeat scan rectum volume was displaced outside the planning scan contours, and wall movements of up to 30 mm were observed. Margins of 16 mm anterior and 11 mm posterior encompassed all rectal motion except for the two most displaced rectum walls in each of these directions, in 89% of the patients. Using a recently published statistics-based recipe, margins of 6 mm anterior and 5 mm posterior accounted for the systematic rectum variation, i.e. the average wall position, in 90% of the patients. Adding anterior margin only caused consistent increases (up to 20%) in the fraction of the volume inside the high-dose region (40-70 Gy) compared to the DVH of rectum only. When using both anterior and posterior margins only small shifts (<5%) in the volume fractions were observed. CONCLUSIONS: Rectum PRV margins of 5-6 mm will encompass the systematic component of rectum motion, while margins up to 16 mm are required to also account for most of the random variation. Use of anterior margins only caused large shifts in the DVHs in the clinically significant dose range, while only minor shifts were seen when using both anterior and posterior margins.

Aged↗

Emptying the rectum before treatment delivery limits the variations of rectal dose - volume parameters during 3DCRT of prostate cancer.

PURPOSE: To investigate the impact of rectum motion on dose - volume histograms of the rectum including filling and of the wall (DVH and DWH, respectively), during 3D-conformal radiotherapy (3DCRT) for localized prostate cancer. MATERIALS AND METHODS: Ten patients received a planning CT scan (CT(0)) and 11-14 CT during 3DCRT for prostate cancer (total CT scans=126). CT images were 3D matched using bony anatomy. A single observer drew the external contours of rectum and rectum wall and the CTV (prostate + seminal vesicles) on CT(0). Patients were asked to empty their rectum before every CT, as generally performed at the Institute for Cancer Research and Treatment (IRCC) before treatment delivery. Bladder was kept full by drinking 500 cm(3) of water 60 min before the scan, according to our protocol. A 4-field box 3DCRT technique was planned and dose statistics/dose - volume histograms of the rectum were calculated for each contour referred to CT(0),CT(1),...,CT(n) for each patient. Average DVHs during treatment were calculated along with their standard deviation (SD(rand)) and compared to the planned DVH. The analyses on the patient population included the assessment of systematic deviation (average difference and SD, named SD(sys)) as well as the average SD(rand) value expressing the random component of organ motion. Rectum shifts were also assessed by anterior and lateral BEV projections. RESULTS: As to the rectum, 8/10 patients showed a "better" average DVH than DVH on CT(0). Wilcoxon test showed a statistically significant reduction when correlating the difference Delta between the average DVH during therapy and planning DVH at CT(0): for instance V(70)Delta = -3.6% and p = 0.022, V(50)Delta = -5.5% and p = 0.022, D(med)Delta = -3.2 Gy and p = 0.007. Average values of DVH systematic difference (average difference between planning scan and treatment), standard deviations (SD(sys)) and average standard deviations of the random fluctuation (SD(random)) were -4.0%, 4.7% and 6.6%, respectively. Whilst the fluctuation results were slightly smaller for DWH. Volume analysis showed a slight systematic variation of the rectal volume between planning and treatment BEV. The average rectal volume during therapy was larger than at the planning CT in 8/10 patients. The systematic shifts of the rectal wall between the planning phase and the treatment were rather small, both below and above the flexure. The larger random fluctuation of the rectum shape was found to be in the cranial half (1 SD=4.4 mm). CONCLUSIONS: The practice of carefully emptying the rectum during simulation and therapy for prostate cancer, which is a safe and simple procedure, reduces the impact of organ motion on dose - volume parameters of the rectum.

Dose-Response Relationship, Radiation↗

Normal tissue complication probabilities correlated with late effects in the rectum after prostate conformal radiotherapy.

PURPOSE: Radiation therapy of deep-sited tumours will always result in normal tissue doses to some extent. The aim of this study was to calculate different risk estimates of late effects in the rectum for a group of cancer prostate patients treated with conformal radiation therapy (CRT) and correlate these estimates with the occurrences of late effects. Since the rectum is a hollow organ, several ways of generating dose-volume distributions over the organ are possible, and we wanted to investigate two of them. METHODS AND MATERIALS: A mathematical model, known as the Lyman-Kutcher model, conventionally used to estimate normal tissue complication probabilities (NTCP) associated with radiation therapy, was applied to a material of 52 cancer prostate patients. The patients were treated with a four field box technique, with the rectum as organ at risk. Dose-volume histograms (DVH) were generated for the whole rectum (including the cavity) and of the rectum wall. One to two years after the treatment, the patients completed a questionnaire concerning bowel (rectum) related morbidity quantifying the extent of late effects. RESULTS: A correlation analysis using Spearman's rank correlation coefficient, for NTCP values calculated from the DVHs and the patients' scores, gave correlation coefficients which were not statistically significant at the p<0.01 level. The correlation coefficients based on histograms of the whole rectum were larger than those derived from histograms of the rectum wall. Also, simpler descriptive measures as Dmax, of the whole rectum, correlated better to observed late toxicity than Dmax derived from histograms of the rectum wall. Correlation coefficients from "high-dose" measures were larger than those calculated from the NTCP values. Accordingly, as the volume parameter of the Lyman-Kutcher model was reduced, raising the impact of small high-dose volumes on the NTCP values, the correlation between observed effects and NTCP values became significant at p<0.01 level. CONCLUSIONS: 1) High-dose levels corresponding to small volume fractions of the cumulative dose-volume histograms were best correlated with the occurrences of late effects in the rectum as measured with questionnaires. This is compatible with a more serial organisation of the rectal tissue architecture than previously reported. 2) Reducing the Lyman-Kutcher model's volume parameter, thus allowing small high-dose regions to determine the NTCP, improved the correlation, but not beyond that of high-dose levels corresponding to small volume fractions of the cumulative dose-volume histograms.

Diarrhea↗

Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancer.

BACKGROUND AND PURPOSE: In 3D treatment planning of low dose rate brachytherapy of cervical carcinoma the dose in bladder and rectum can be estimated from dose-volume histograms (DVHs). In this study, the influence of inter-observer variation in delineation of bladder and rectum on DVHs and dose at specific bladder and rectum points was investigated. MATERIALS AND METHODS: Three observers delineated bladder and rectum on axial CT images of ten patients. The highest minimum dose in bladder and rectum was determined for, respectively, 2 cm(3) (D(2)) and 5 cm(3) (D(5)), as well as the dose at specific points placed on the bladder and rectum wall. RESULTS: The inter-observer variation in D(2) was 10% (1 average relative SD) in bladder and 11% (1 SD) in rectum. In D(5) the variation was 8% (1 SD) in bladder and 11% in rectum. The variation in the bladder point was 13% (1 SD) and in the rectum point 11% (1 SD). Differences in delineation among the observers were caused by unclear organ boundaries on the CT images. CONCLUSIONS: Taking the inter-observer variation caused by delineation differences into account, dose in bladder and rectum can be determined within an accuracy of about 10% (1 SD).

Brachytherapy↗

The location and contents of the lateral ligaments of the rectum: a study in human soft cadavers.

PURPOSE: This study was designed to identify the location of the lateral ligaments of the rectum and to reveal its contents. METHODS: From 18 human soft cadavers (9 males), 18 pelves were sagittally sectioned into 36 hemipelvic specimens affording good anatomic view of the lateral aspect of the rectum. All of them were dissected and mobilized by using sharp technique under direct vision by one surgeon to avoid confounding factor. The lateral ligaments of the rectum were identified and the distances from the center of its pelvic attachment to the promontory of sacrum and coccyx were measured. After measurement, they were transected and brought for histologic examination. RESULTS: In 36 hemipelvic specimens, 18 lateral ligaments of the rectum were found on the right side of the rectum and 18 were found on the left side. One cadaver had no lateral ligament on the right side and another had two lateral ligaments on the right side 3-cm apart. The location of the lateral ligaments was posterolateral to the rectum. The distance from the lateral ligament to sacral promontory on right side was 8.14 +/- 1.82 cm (mean +/- standard deviation) and 8.14 +/- 1.22 cm on left side. The distances from the lateral ligament to coccyx on the right and left sides were 5.12 +/- 1.4 cm and 4.88 +/- 1.29 cm, respectively. The content of the lateral ligaments of the rectum consisted of loose connective tissue with cluster of small nerves. No artery was detected in all specimens. The small arterioles and venules were discovered in only four specimens. CONCLUSIONS: The lateral ligaments of the rectum were located at posterolateral side of the rectum. They were closer to the coccyx than to the sacral promontory. Its component was loose connective tissue containing multiple small nerves. There was no artery found in any lateral ligaments by histologic study. Small arterioles and venules were detected 11 percent.

Adult↗

Distribution and origin of extrinsic nerve fibers containing calcitonin gene-related peptide, substance P and galanin in the rat upper rectum.

The distributions of nerve fibers containing calcitonin gene-related peptide (CGRP), substance P (SP) and galanin (GAL) were examined in the rat rectum of mutants rats, aganglionic rats (AGRs), which completely lack the intramural nerve cells in the large intestine, and of their normal littermates. The origin of extrinsic peptide-containing nerve fibers was examined using retrograde tracing combined with immunohistochemistry in normal rats. In the rectum of normal rats, CGRP-, SP- and GAL-immunoreactive varicose fibers were observed throughout all layers of the rectal wall, and immunoreactive nerve cells were present in the enteric ganglia of colchicine-treated rats. In the aganglionic rectum of AGR, a rich supply of CGRP-immunoreactive fibers was observed in the mucosa, around the blood vessels, and in the submucous and intermuscular spaces. SP- and GAL-immunoreactive fibers in the aganglionic rectum showed a similar distribution to CGRP-immunoreactive fibers but were less dense. These results suggest that most of CGRP-positive fibers in the rectum are extrinsic whereas a large part of SP- or GAL-positive fibers are intrinsic. Fluoro-gold injected into the upper rectum of normal rat labelled nerve cells (less than 10% of total ganglion cells) in the lumbar (L1 and L2) and lumbosacral (L6 and S1) dorsal root ganglia. More than half of nerve cells in the dorsal root ganglia (L6 and S1) projecting to the rectum were immunoreactive for CGRP, and less than 10% were immunoreactive for SP or GAL. Comparison of serial sections of the dorsal root ganglion revealed that about half of the CGRP-immunoreactive cells were also positive for SP or GAL. These results indicate that SP- or GAL-positive neurons projecting to the rectum are scarce in the dorsal root ganglia. The present investigation suggests that CGRP-containing nerves are visceral afferents forming a major component of the sensory innervation of the rat rectum, and SP- and GAL-containing nerves which share their extrinsic origins appear to form a lesser proportion of the sensory innervation.

Animals↗

Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer.

BACKGROUND AND PURPOSE: The goal of this work is to develop and evaluate strategies to reduce the uncertainty in the prostate position and rectum shape that arises in the preparation stage of the radiation treatment of prostate cancer. PATIENTS AND METHODS: Nineteen prostate cancer patients, who were treated with 3-dimensional conformal radiotherapy, received each a planning CT scan and 8-13 repeat CT scans during the treatment period. We quantified prostate motion relative to the pelvic bone by first matching the repeat CT scans on the planning CT scan using the bony anatomy. Subsequently, each contoured prostate, including seminal vesicles, was matched on the prostate in the planning CT scan to obtain the translations and rotations. The variation in prostate position was determined in terms of the systematic, random and group mean error. We tested the performance of two correction strategies to reduce the systematic error due to prostate motion. The first strategy, the pre-treatment strategy, used only the initial rectum volume in the planning CT scan to adjust the angle of the prostate with respect to the left-right (LR) axis and the shape and position of the rectum. The second strategy, the adaptive strategy, used the data of repeat CT scans to improve the estimate of the prostate position and rectum shape during the treatment. RESULTS: The largest component of prostate motion was a rotation around the LR axis. The systematic error (1 SD) was 5.1 degrees and the random error was 3.6 degrees (1 SD). The average LR-axis rotation between the planning and the repeat CT scans correlated significantly with the rectum volume in the planning CT scan (r=0.86, P<0.0001). Correction of the rotational position on the basis of the planning rectum volume alone reduced the systematic error by 28%. A correction, based on the data of the planning CT scan and 4 repeat CT scans reduced the systematic error over the complete treatment period by a factor of 2. When the correction was carried out later in the treatment (based on the data of more scans) the overall reduction was less. For the rectum, the first strategy performed best at the upper anterior side, where a reduction of the anterior-posterior displacement of 30% could be achieved. The systematic error could be reduced by 43% for the whole rectum by using the data of 4 repeat CT scans and the planning CT scan. CONCLUSIONS: Both the pre-treatment as well as the adaptive correction strategy reduced the systematic error in the prostate position and rectum position and shape. A smaller systematic error makes it possible to safely reduce the margin around the clinical tumor volume, so that normal tissues can be spared or the prescription dose can be escalated.

Humans↗

The use of a transverse CT image for the estimation of the dose given to the rectum in intracavitary brachytherapy for carcinoma of the cervix.

BACKGROUND AND PURPOSE: The three-dimensional (3D) dose distribution in combination with 3D anatomy of 13 patients treated for cervical carcinoma with intracavitary brachytherapy was analyzed. The aim of this study was to determine the correlation between a dose value obtained from the integral dose volume histogram (DVH) of the rectum and (a) the Nederlands Kanker Instituut (NKI) point of reference for the rectum dose (R) and (b) the highest dose to the frontal rectum wall in the transverse CT slice near the top of the vagina through point R. RESULTS: The correlation between the DVH rectum dose value for 2 cm3 in the highest dose region and the rectum dose at point R was poor (regression coefficient 0.50). On the contrary, however, the correlation between the DVH rectum dose value for 2 cm3 in the highest dose region and the maximum rectum dose value in a transverse CT slice through point R was good (regression coefficient 0.90). CONCLUSIONS: The maximal rectum dose value obtained from a transverse CT slice near the top of the vagina through point R was found to be a more representative point for the rectal dose burden and might therefore show a good correlation with complications. The point of reference for the rectal dose (R) was found not to be a reliable estimation of the maximal dose in the rectum.

Brachytherapy↗

A model to simulate day-to-day variations in rectum shape.

PURPOSE: To develop a model that predicts possible rectum configurations that can occur during radiotherapy of prostate cancer on the basis of a planning CT scan and patient group data. MATERIALS AND METHODS: We used a stochastic shape description model with a limited number of parameters (area, area difference, and curvature) on a slice-by-slice basis to simulate rectum motion. The probability distributions of the chosen parameters were obtained from a group of 9 reference patients, who each received 15-17 repeat CT scans. We used a Monte Carlo technique to generate different rectum configurations from the probability distributions. We verified the model by comparing dose-wall histograms (DWHs) of the originally delineated rectal contours and simulated rectums for a three-field treatment technique with a prescription dose of 78 Gy. The 15-17 sets of rectal contours of each patient are regarded as the golden standard and provide a good estimate of the actual dose received during the treatment. We determined the equivalent uniform dose (EUD) for a quantitative comparison between the actual dose, the dose predicted on the basis of the simulations, and the dose predicted on the basis of a single planning CT scan. RESULTS: The simulated rectum configurations yield a better estimate of the actual dose in the rectal wall than the rectum in the planning CT scan alone. The differences between the EUD based on the planning CT scan and the actual EUD ranged between -1.1 Gy and 2.1 Gy, with respect to a mean actual EUD of 69.8 Gy. This range is smaller for the EUD based on the simulated rectums, namely -0.4 Gy to 0.6 Gy. Furthermore, the simulation generates a set of rectum configurations that provides an estimate of the variation in DWHs during the course of the treatment. This estimate can be used in addition to the DWH of the planning CT scan in the analysis of gastrointestinal toxicity. CONCLUSIONS: To simulate rectum shapes, we have developed a model that can be used in addition to the information available in the planning CT scan in the analysis of the received dose to the rectal wall during radiotherapy of prostate cancer.

Algorithms↗

Comparative effects of some autonomic drugs on lizard (Agama agama) and tortoise (Kinixys crosa) isolated rectum.

The effects of some cholinomimetic and sympathomimetic drugs have been investigated on the isolated rectal muscles of West African rainbow lizard (Agama agama) and land tortoise (Kinixys crosa). Acetylcholine and its natural or synthetic analogues evoked concentration-related atropine-sensitive contractions of the muscle preparations, whereas all the catecholamines examined relaxed the lizard (and guinea-pig), but not the tortoise, isolated rectum in a dose-dependent fashion. The ganglionic stimulant drugs used, nicotine and DMPP, did not produce any effect on the isolated rectum of the two reptiles, although they contracted the guinea-pig isolated rectum in a concentration-dependent manner. Concentrations of physostigmine, which induced spasms or contractions in the isolated rectum of the guinea-pig, failed to excite reptilian rectal muscle preparations. Histamine induced biphasic responses in the lizard isolated rectum without affecting the isolated rectum of the tortoise. Serotonin (5-HT) which contracted the isolated rectum of the guinea-pig (like histamine) also provoked variable contractions of the lizard rectum but did not affect the tortoise isolated rectum. It is therefore concluded that although the rectal smooth muscles of these two terrestrial West African reptiles possess cholinergic innervation with mainly "muscarinic" cholinoceptors, their autonomic innervation differs from that of a conventional mammalian (e.g. guinea-pig) gastrointestinal tract smooth muscle.

Acetylcholine↗