Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Methiocarb”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

The relationship between dermal pesticide exposure by fruit harvesters and dislodgeable foliar residues.

Dermal pesticide exposure rates, expressed in mg/hr, by strawberry and blueberry harvesters and dislodgeable foliar pesticide residues were determined in 7 separate field experiments during 1981-1983 in California and Oregon. The pesticides which were studied included captan, vinclozolin, carbaryl, and methiocarb. A positive correlation between these two parameters was found and compared with literature values involving different pesticides and tree crops. The ratio between dermal exposure rate and dislodgeable foliar residues, the units of which are area/time, may have a possible use as an empirical factor for a first approximation of dermal exposure rates by fruit harvesters without the involvement of human subjects.

Adolescent↗

Epidemiological features of snail and slug bait poisoning in dogs and cats.

Snail and slug baits were the most common cause of poisoning in dogs and cats in a survey of 34 veterinary practices. During a 7-month period, 280 dogs and 12 cats were poisoned by metaldehyde (57%) or methiocarb (43%) containing baits with case fatality rates of 8.1% and 9.1% in dogs and 16.7% and 50% in cats, respectively. The ages of poisoned dogs ranged from 2 months to 17 years and cats from 3 months to 5 years. There was no decrease in frequency of poisoning or case fatality rate demonstrated with increasing body size in dogs. Poisoning was most frequent in the month of October. Baits were eaten off the ground or obtained from storage areas, often despite a variety of preventive measures. It is suggested that these products should be reformulated to make them less attractive to domestic pets.

Acetaldehyde↗

Multi-residue analysis of N-methylcarbamate pesticides and their hydrolytic metabolites in environmental waters by use of solid-phase extraction and micellar electrokinetic chromatography.

A method for the simultaneous separation and determination of N-methylcarbamate pesticides and their hydrolytic metabolites by micellar electrokinetic chromatography (MEKC) was developed. A mixture of five pesticides (carbaryl, propuxur, carbofuran, aminocarb, and methiocarb) and their corresponding phenols was studied to optimize the separation of its components in terms of various electrophoretic parameters such as buffer type, pH and concentration, sodium dodecyl sulfate concentration, injection conditions, and applied voltage. Excellent separation of all ten analytes was achieved within about 20 min. The optimized method was used for determinations in environmental water samples. Sample volumes of 250 mL were first preconcentrated in the pesticides and metabolites by passage through a LiChrolut EN sorbent column and then further enriched by on-column stacking. Dynamic ranges of 40 ng/L - 6 microg/L, limits of detection at the nanogram-per-liter level, and relative standard deviations from 2.6 to 7.4% were obtained. The proposed method surpasses high-performance liquid chromatography (HPLC) in separation efficiency. In fact, it provides more expeditious separations and allows more flexible adjustment of the selectivity. Also, it enables the quantification for the analytes studied in this work with decreased limits of detection.

Carbamates↗

Behaviour of carbamate pesticides in gas chromatography and their determination with solid-phase extraction and solid-phase microextraction as preconcentration steps.

This work reports a study of the chromatographic behaviour of seven carbamate pesticides (aldicarb, carbetamide, propoxur, carbofuran, carbaryl, methiocarb, and pirimicarb) by gas chromatography-mass spectrometry (GC-MS). Variables such as injector temperature, solvent, injection mode, and the degree of ageing of the chromatographic column were studied. One of the aims of this work was to achieve a controlled decomposition of carbamates by a solid-phase microextraction (SPME) preconcentration step with a polyacrylate fibre in order to obtain reproducible chromatographic signals of the degradation products. Optimisation of the SPME process was accomplished by means of experimental design. Several methods using ultrapure water were developed with different preconcentration configurations: SPME-GC-MS, SPE followed by SPME-GC-MS, and SPE plus GC-MS. For all the pesticides studied, method detection limit (MDL) values below 0.1 microg L-1 were reached in at least one of the proposed configurations.

Carbamates↗

A convenient method to discriminate between cytochrome P450 enzymes and flavin-containing monooxygenases in human liver microsomes.

Liver microsomes are a frequently used probe to investigate the phase I metabolism of xenobiotics in vitro. Structures containing nucleophilic hetero-atoms are possible substrates for cytochrome P450 enzymes (P450) and flavin-containing monooxygenases (FMO). Both enzymes are located in the endoplasmatic reticulum of hepatocytes and both need oxygen and NADPH as cofactors. The common method to distinguish between the two enzyme systems is to use the thermal inactivation of FMO and to inhibit P450 completely with carbon monoxide, N-octylamine or N-benzylimidazole. In the literature no indication could be found that the heat inactivation of FMO does not affect any of the human P450 enzymes or that the overall P450 inhibitors inhibit the different human P450 enzymes sufficiently and do not affect the FMO. The effect of N-benzylimidazole and heat inactivation was tested on specific activities of seven P450 enzymes in human liver microsomes, 1A2, 2A6, 2C9, 2C19, 2D6, 3A4/5, and 2E1, using methoxyresorufin O-demethylation, coumarin 7-hydroxylation, (S)-warfarin 4-hydroxylation, (S)-(+)-mephenytoin 4-hydroxylation, dextrometorphan O-demethylation, oxidation of denitronifedipine, and chlorzoxazone 6-hydroxylation respectively. The sulfoxidation of methimazole (MMI) was used as a specific probe for the determination of FMO activity. Methimazole sulfoxidation was compared with the well known assay for FMO metabolism, the formation of N,N-dimethylaniline (DMA) N-oxide, to be confirmed as an exclusively FMO mediated reaction. The participation of P450 and FMO in the sulfoxidation of four sulfur containing peptides, ametryne; terbutryne, prometryne and methiocarb was investigated using human liver microsomes. All four reactions were demonstrated to be catalysed predominantly by cytochrome P450.

Aniline Compounds↗

Derivatization reactions of carbamate pesticides in supercritical carbon dioxide.

Supercritical fluid carbon dioxide (SC-CO(2)) has been used to dissolve derivatizing agents (e.g. heptafluorobutyric anhydride, HFBA, and pyridine), which also act as a modifier in the fluid phase, for simultaneous extraction and derivatization of carbamates from the sample matrix. The derivatized carbamate pesticides (carbaryl, 3-hydroxycarbofuran, carbofuran, aldicarb, methiocarb) were then analyzed by GC-ECD or GC-MS with excellent sensitivity. Extraction and conversion of the carbamates was complete, as indicated by HPLC with post-column hydrolysis and o-phthalaldehyde derivatization then fluorescence detection. GC-MS (ion trap) was also used to confirm the formation of the carbamate derivatives. Compared with the same HFBA reaction in an organic solvent the derivatization reaction time was considerably shorter in SC-CO(2.) The described approach, combining both extraction and derivatization, simplifies the analysis of carbamate pesticides and eliminates the use of organic solvents associated with the derivatization step.

Carbamates↗

Determination of several pesticides in water by solid-phase extraction, liquid chromatography and electrospray tandem mass spectrometry.

The analysis of pesticides in water samples is a problem of primary concern for quality control laboratories due to the toxicity level of these compounds and their public health risk. In order to evaluate the impact of pesticides in the Lisbon drinking water supply system, following the requirements of the European Union Directive 98/83/EC, we developed and validated an analytical method based on the combination of solid-phase extraction with liquid chromatography and tandem mass spectrometry. In this work, several pesticides were studied: imidacloprid, dimethoate, cymoxanil, carbendazime, phosmet, carbofuran, isoproturon, diuron, methidathion, linuron, pyrimethanil, methiocarbe, tebuconazole and chlorpyrifos. Several parameters of the electrospray source were optimized in order to get the best formation conditions of the precursor ion for each pesticide, namely capillary and extractor voltage, cone voltage, cone gas flow rate and desolvation gas flow rate. After optimization of the collision cell energy of the triple quadrupole, two different precursor ion-product ion transitions were selected for each pesticide, one for quantification and one for qualification, and these ions were monitored under time-scheduled multiple reaction monitoring (MRM) conditions. The selection of specific fragment ions for each pesticide guarantees a high degree of selectivity as well as additional sensitivity to quantify trace levels of these pesticides in water samples. This method showed excellent linearity ranges for all pesticides, with correlation coefficients greater than 0.9989. Determination limits (between 0.0041 and 0.0480 microg/L), precision (RSD <9.18%), accuracy and recovery studies in several water samples using solid-phase extraction were also performed.

Chromatography, Liquid↗

Effects of currently used pesticides in the AhR-CALUX assay: comparison between the human TV101L and the rat H4IIE cell line.

The aryl hydrocarbon receptor (AhR) is a ligand-activated transcription factor that mediates many of the biologic and toxicological effects of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and related compounds. The in vitro chemically activated luciferase expression (CALUX) assay has been proven to be a rapid and sensitive assay for assessing the potency of AhR-activating compounds. We have used the AhR-CALUX assay to investigate the AhR-mediated activity of the persistent organochlorine insecticide dieldrin and twenty-two pesticides currently used in Denmark by employing the rat H4IIE and the human TV101L hepatoma cell lines. In comparison the results indicated that the rat H4IIE cell line is more sensitive than the human TV101L for detection of TCDD inducing AhR-CALUX activity. The pesticides iprodione, chlorpyrifos and prochloraz showed dose-dependent AhR agonistic effects in both cell lines at concentrations above 10, 1 and 1 microM, respectively. However, some pesticides (methiocarb, chlorothalonil, tribenuron-methyl, paclobutrazol and tolchlofos-methyl) elicited differential responses in the two cell lines.

Animals↗

Lipoxygenase-mediated hydrogen peroxide-dependent N-demethylation of N,N-dimethylaniline and related compounds.

To date, studies of xenobiotic N-demethylation have focused on heme-proteins such as P450 and peroxidases. In this study we investigated the ability of non-heme iron proteins, namely soybean lipoxygenase (SLO) and human term placental lipoxygenase (HTPLO) to mediate N-demethylation of N,N-dimethylaniline (DMA) and related compounds in the presence of hydrogen peroxide. In addition to being hydrogen peroxide dependent, the reaction was also dependent on incubation time, concentration of enzyme and DMA and the pH of the medium. Using Nash reagent to estimate formaldehyde production, we determined the specific activity for SLO mediated N-demethylation of DMA to be 200 + 18 nmol HCHO/min per mg protein or 23 +/- 2 nmol/min per nmol of enzyme, while that of HTPLO was 33 +/- 4 nmol HCHO/min per mg protein. Nordihydroguaiaretic acid (NDGA), a classical inhibitor of lipoxygenase (LO), as well as antioxidants and free radical reducing agents, caused a marked reduction in the rate of production of formaldehyde from DMA by SLO. Besides N,N-dimethylaniline, N-methylaniline, N,N,N',N'-tetramethylbenzidine, N,N-dimethyl-p-phenylenediamine, N,N-dimethyl-3-nitroaniline and N,N-dimethyl-p-toluidine were also demethylated by SLO. The formation of a DMA N-oxide was not detected. Preliminary experiments suggested SLO-mediated hydrogen peroxide-dependent S-dealkylation of methiocarb or O-dealkylation of 4-nitroanisole does not occur.

Aniline Compounds↗

Multiresidue analysis of seventeen pesticides in wine by gas chromatography with mass-selective detection.

We have developed a multiresidue method permitting the simultaneous quantitation of 17 pesticides in wine: dicloran, dimethoate, diazinon, chlorpyrifos-methyl, vinclozolin, carbaryl, methiocarb, dichlofluanid, parathion-ethyl, triadimefon, procymidone, myclobutanil, iprodione, imidan, dicofol, phosalone and azinphos-methyl. Solid-phase extraction of 0.5 ml of wine sample is followed by direct injection of 1 microl of the eluent onto a DB-5 MS gas chromatographic column followed by mass-selective detection using one target and two qualifier ions for each pesticide. The extraction and injection steps are carried out with automatic instrumentation. Good resolution of all compounds was achieved with a run-time approximating 23 min. Detection and quantitation limits were around 2 microg/l and 10 microg/l, respectively, with linear calibration curves up to 3 mg/l for most constituents. Recovery in half the compounds was >90%, and >80% in most of the remainder. Imprecision (relative standard deviation) was <10% for most pesticides and <18% in all. Further analytes can be added to the repertoire without difficulty. The method merits consideration together with four other multiresidue methods now available that offer similar analytical characteristics, slower run-times, and a different selection of analytes.

Gas Chromatography-Mass Spectrometry↗

Simplified method for the analysis of some carbamate insecticides in foliage, forest soil and fish tissue by direct gas-liquid chromatography.

A simplified and sensitive method for the analysis of eight carbamate insecticide residues in foliage, forest soil and fish tissue by direct gas-liquid chromatography (GLC) is described. After fortification, the carbamate residues were extracted from the natural substrates by homogenization in ethyl acetate. The interfering co-extratives present in the crude extracts were removed by filtration through Whatman GF/A glass microfibre after coagulation. The carbamate residues were re-extracted into dichloromethane and directly analyzed intact by GLC with a Tracor Model 702 nitrogen-phosphorus detector. The rate of recovery for aminocarb, carbofuran, carbaryl, methomyl, mexacarbate, pirimicarb and propoxur was better than 80% at 5.0-ppm and 0.50-ppm levels. Slightly less than 60% was recovered for methiocarb.

Animals↗

Evaluation of Amberlite XAD-2 as the extractant for carbamate insecticides from natural water.

A rapid and sensitive analytical technique to quantify carbamate insecticides at nanogram levels is reported using resin column and sorption, and desorption followed by N-P gas-liquid chromatography (GLC) analysis. The carbamates were extracted from natural water by percolation through a column of Amberlite XAD-2, followed by elution with ethyl acetate. The carbamate residues were directly analyzed by GLC with a Tracor Model 702 N-P detector. The recoveries for several carbamates including aminocarb, mexacarbate, carbaryl, propoxur, carbofuran, pirimicarb and methiocarb were from 86 to 108% at 1.0 and 0.01 ppm levels. Only 41 to 58% was recovered for methomyl. The extraction efficiency of Amberlite XAD-2 was pH-dependent as indicated in the extraction of aminocarb. More than 90% of the added aminocarb was recovered from phosphate buffer by the described method at pH 5.0 to 7.5 at 5.0 and 0.5 ppm levels.

Carbamates↗

High-performance liquid chromatographic determination of aryl N-methylcarbamate residues using post-column hydrolysis electrochemical detection.

A high-performance liquid chromatographic technique is reported which selectively detects the phenolic moiety of aryl N-methylcarbamates at low nanogram levels. The carbamates are separated on a C-8 column using an acetonitrile-water gradient mobile phase. The eluted carbamates are hydrolyzed in-line by post-column addition of base, which also serves as electrolyte in the electrochemical (coulometric) detection of the resulting phenols. The technique was tested with six carbamates (bufencarb, carbaryl, carbofuran, 3-hydroxycarbofuran, isoprocarb and methiocarb) and four crops (apples, cabbage, grapes and tomatoes). Optimum detector responses and stability for the carbamates were attained at 0.60 V. Detector response to the carbamates in the presence of crop coextractives was 99% of theoretical with a standard deviation of 2.8% at the 0.05- to 0.1-ppm fortification level. The lower limit of quantitation is 0.01 ppm. Other electrochemical detectors were evaluated for suitability for this work.

Carbamates↗

Optimization and evaluation of low-pressure gas chromatography-mass spectrometry for the fast analysis of multiple pesticide residues in a food commodity.

A fast method of analysis for 20 representative pesticides was developed using low-pressure gas chromatography-mass spectrometry (LP-GC-MS). No special techniques for injection or detection with a common quadrupole GC-MS instrument were required to use this approach. The LP-GC-MS approach used an analytical column of 10 m x 0.53 mm I.D., 1 microm film thickness coupled with a 3 m x 0.15 mm I.D. restriction capillary at the inlet end. Thus, the conditions at the injector were similar to conventional GC methods, but sub-atmospheric pressure conditions occurred throughout the analytical column (MS provided the vacuum source). Optimal LP-GC-MS conditions were determined which achieved the fastest separation with the highest signal/noise ratio in MS detection (selected ion monitoring mode). Due to faster flow-rate, thicker film, and low pressure in the analytical column, this distinctive approach provided several benefits in the analysis of the representative pesticides versus a conventional GC-MS method, which included: (i) threefold gain in the speed of chromatographic analysis; (ii) substantially increased injection volume capacity in toluene; (iii) heightened peaks with 2 s peak widths for normal MS operation; (iv) reduced thermal degradation of thermally labile analytes, such as carbamates; and (v) due to larger sample loadability lower detection limits for compounds not limited by matrix interferences. The optimized LP-GC-MS conditions were evaluated in ruggedness testing experiments involving repetitive analyses of the 20 diverse pesticides fortified in a representative food extract (carrot), and the results were compared with the conventional GC-MS approach. The matrix interferences for the quantitation ions were worse for a few pesticides (acephate, methiocarb, dimethoate, and thiabendazole) in LP-GC-MS, but similar or better results were achieved for the 16 other analytes, and sample throughput was more than doubled with the approach.

Food Contamination↗

On-column trace enrichment by sequential frontal and elution electrochromatography II. Enhancement of sensitivity by segmented capillaries with z-cell configuration--application to the detection of dilute samples of moderately polar and nonpolar pesticides.

An on-column trace enrichment method for capillary electrochromatography of dilute samples is described. It involves the sequential use of frontal and elution electrochromatography on a segmented capillary column comprising of two contiguous segments each packed with a different sorbent. While the entering segment is for preconcentration by frontal electrochromatography the second segment is much longer and is meant for separation of the enriched analytes in the subsequent elution electrochromatography step. The preconcentration segment is usually packed with a sorbent that affords the highest affinity towards the solutes of interest while the separation segment is packed with a stationary phase that exhibits the highest selectivity and separation efficiency for the analytes. The detection is performed in the UV using a z-cell configuration for achieving an increased path length for detection. The effectiveness of this on-column trace enrichment is demonstrated on dilute samples of moderately polar solutes (e.g., carbamate insecticides) and nonpolar solutes (e.g., pyrethroid insecticides). Under optimal frontal and elution electrochromatography conditions. 817- and 1100-fold sensitivity increase are achieved for permethrin (a pyrethroid insecticide) and methiocarb (a carbamate insecticide), respectively, with a UV detector. The method is demonstrated with real water samples (e.g., tap and lake water samples) spiked with carbamate and pyrethroid insecticides. The limits of detection for the pesticides achieved in tap and lake waters reached 10(-8) to 10(-9) M.

Chromatography, Micellar Electrokinetic Capillary↗

Comparison of microextraction procedures to determine pesticides in oranges by liquid chromatography-mass spectrometry.

A liquid chromatographic-mass spectrometric method has been developed for the determination of bitertanol, carbendazim, fenthion, flusilazole, hexythiazox, imidacloprid, methidathion, methiocarb, pyriproxyfen and trichlorfon. Two procedures, based on stir bar sorptive extraction (SBSE) and matrix solid-phase dispersion (MSPD), have been evaluated for the extraction of these compounds in oranges. Their respective advantages and disadvantages are also discussed. The recoveries obtained by MSPD ranged from 47 to 96% and the relative standard deviations (RSDs) ranged from 1 to 15%, whereas with the SBSE method the recoveries were between 8 and 84% and the RSDs between 4 and 16%. Although, the limits of quantitation of most compounds are much better (0.001-0.05 mg kg(-1)) by SBSE, it is not suitable to determine some polar pesticides as carbendazim, imidacloprid and trichlorfon. Results obtained by both methods were compared, in terms of sensitivity and selectivity, with a classical ethyl acetate extraction method, and the three methods were applied to analyze real samples. As MSPD is easier to perform, faster than the organic solvent extraction, and shows equal accuracy and resolution, its application for analyzing pesticides in oranges is recommended.

Chromatography, Liquid↗

Multiresidue analysis of carbamate pesticides in soil by sonication-assisted extraction in small columns and liquid chromatography.

A rapid multiresidue method has been developed for the analysis of carbamate insecticides (oxamyl, methomyl, propoxur, carbofuran, carbaryl and methiocarb) in soil. The method is based on the sonication-assisted extraction of soil samples placed in small columns using a low volume of methanol. Residue levels in soil were determined by reversed-phase high-performance liquid chromatography with fluorescence detection after post-column derivatisation. The separation of carbamates is performed on a C8 column with water-methanol as mobile phase. Recovery studies were carried out at 0.5, 0.1 and 0.01 microg/g fortification levels and average recoveries obtained for carbamates ranged from 82 to 99% with relative standard deviations between 0.4 and 10%. The effect of residue residence time and soil moisture content on the insecticide recovery was also studied. The method is linear over the range assayed, from 0.1 to 1 microg/ml. The detection limit for the carbamates varied from 1.6 to 3.7 microg/kg and the quantification limit obtained was 10 microg/kg. The emission and excitation allowed the confirmation of residues at levels around 0.1 microg/g.

Carbamates↗

Biological and chemical analysis of the toxic potency of pesticides in rainwater.

A newly developed method for measuring the integrated esterase inhibiting potency of rainwater samples was applied in practice, and the results are compared to the toxic potency calculated from concentrations of 31 organophosphate (OP) and carbamate pesticides, out of a total of 66 chemically analyzed pesticides. In addition, the general toxic potency of the rainwater samples was evaluated in a microtiter luminescence assay with Vibrio fischeri bacteria. Rainwater samples were collected over four consecutive 14-day periods in both open and wet-only samplers. The esterase inhibiting potency of the open rainwater samples (expressed as ng dichlorvos-equivalents/l) corresponded well with the chemical analyses of the rainwater samples collected by both types of samplers (r = 0.83-0.86). By far, the highest esterase inhibiting potency was found in a sample collected in an area with intense horticultural activities in June, and was attributed to high concentrations of dichlorvos, mevinphos, pirimiphos-methyl and methiocarb. The esterase inhibiting potency of this sample was equivalent to a dichlorvos concentration of 1380 ng/l in the rainwater, which is almost 2000 times higher than the maximum permissible concentration (MPC) of dichlorvos set for surface water in Netherlands. Maximum individual concentrations of dichlorvos and pirimiphos-methyl even exceeded the EC50 for Daphnia, suggesting that pesticides in rainwater pose a risk for aquatic organisms. Not all responses of the luminescence-assay for general toxicity could be explained by the analyzed pesticide concentrations. The bio-assays enable a direct assessment the toxic potency of all individual compounds present in the complex mixture of rainwater pollutants, even if they are unknown or present at concentrations below the detection limit. Therefore, they are valuable tools for prescreening and hazard characterization purposes.

Carbamates↗