Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MTC”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

(99)mTc-tetrofosmin SPET in the detection of both primary breast cancer and axillary lymph node metastasis.

The aim of this study was to evaluate the usefulness of (99m)Tc-tetrofosmin single-photon emission tomography (SPET) in the detection of both primary breast cancer and axillary lymph node metastasis. We studied 192 consecutive patients in whom primary breast cancer was suspected on the basis of mammography and/or physical examination. After intravenous injection of 740 MBq (99m)Tc-tetrofosmin, both planar and SPET scintimammography was performed in all patients using a rectangular dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators. In 175 patients with breast cancer at histology, the per-lesion overall sensitivity of SPET and planar imaging for the detection of breast cancer was 95.8% and 75.9% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 96.5% and 79.5% in palpable (P<0.0005) and 90% and 45% in non-palpable lesions (P<0.01). With regard to lesion size, the sensitivity of SPET and planar imaging was, respectively, 90.5% and 45.2% in lesions < or =10 mm ( P<0.0005), 95.3% and 81.4% in lesions of 11-20 mm (P<0.005), 100% and 84.6% in lesions of 21-30 mm (P<0.05) and 100% and 95.8% in lesions >30 mm (P>0.05). In the remaining 17 patients with benign mammary lesions at histology, per-lesion overall specificity of SPET and planar imaging was 76.2% and 85.7% (P>0.05), respectively. Neither SPET nor planar imaging showed false-positive results in non-palpable lesions or in those < or =10 mm. In 173 breast cancer patients submitted to axillary lymph node dissection (ALND), per-axilla overall sensitivity of SPET and planar imaging in the detection of axillary lymph node metastasis was 93% and 52.3% ( P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 100% and 82.6% in palpable nodes (P>0.05), 90.5% and 41.3% in non-palpable nodes (P<0.0005), 92.8% and 35.7% in the presence of < or =3 nodes ( P<0.0005) and 93.2% and 68.2% in the presence of >3 nodes (P<0.005). The specificity of SPET and planar imaging was 91% and 100% (P<0.05), respectively. (99m)Tc-tetrofosmin SPET appears to be a reliable method for the detection of both primary BC and axillary lymph node metastasis, and its diagnostic accuracy exceeds that of (99m)Tc-tetrofosmin planar scintimammography. The use of SPET is particularly important in the identification of small non-palpable primary carcinomas and metastatic axillae with < or =3 non-palpable lymph nodes. More extensive use of SPET appears warranted in the management of breast cancer patients.

Axilla↗

[Incidental diagnosis of medullary thyroid carcinoma (MTC) after performing 123I-metaiodobenzylguanidine (123I-MIBG) gammagraphy].

UNLABELLED: The objective of this clinical note is to emphasize diagnostic efficiency of 123I-MIBG scintigraphy in the initial diagnosis and follow-up of medullary thyroid carcinoma within MEN2. MATERIALS AND METHODS: We present the case of a patient who, during a scintigraphic study with 123I-MIBG for the diagnosis of pheochromocytoma, was unexpectedly found to suffer from medullary carcinoma of the thyroid. Prior to performing the test, we proceeded to block uptake into the thyroid gland through the administration of Lugol. We carried out the scintigraphic study by intravenously injecting 370 MBq 123I-MIBG. RESULTS: A pathological uptake of the radiopharmaceutical compound over the right suprarenal gland, and unexpectedly, over the thyroid gland was detected, thus confirming the existence of medullary carcinoma of the thyroid in this patient, and obtaining the diagnosis of Type MEN2A polyglandular syndrome. CONCLUSIONS: From our experience, we can manifest the value of scintigraphy using 123I-MIBG in the diagnosis and localization of medullary carcinoma of the thyroid. Furthermore, it is indicated in patients suspected of MEN, since it makes it possible to reach a diagnosis of this kind of syndrome through the performance of just one test.

3-Iodobenzylguanidine↗

3'-99mTc-labeling and biodistribution of a CAPL antisense oligodeoxynucleotide.

CAPL is a cancer-related gene shown to be overexpressed during tumor metastasis formation. A CAPL antisense oligodeoxynucleotide (ODN), GX-1, and a random control ODN (CTRL1) were 3'-conjugated to MAG3, labeled with technetium-99m, purified, and the biodistribution of the radiolabeled conjugates in normal mice was studied. A 99mTc-MAG3-GX-1 complex of >97% radiochemical purity was obtained and the product was stable for >6 h as determined by reversed phase high performance liquid chromatography (HPLC). Biodistribution studies of the 99mTc-MAG3-ODNs in groups of four normal mice, sacrificed 5 min and 60 min after injection, demonstrated that the radiolabeled ODNs were distributed in an unspecific manner. The excretion route was mainly urinary. At 60 min, 55.2% of the injected dose of 99mTc-MAG3-GX-1 and 72.4% of 99mTc-MAG3-CTRL1 was found in the urine. This finding is clearly different from previously reported data on tritiated 20-mer phosphodiester ODNs, as well as the unconjugated 99mTc-MAG3 chelate, suggesting that 99mTc-MAG3 coupled to the 3'-end of ODNs has an influence on the biodistribution of the oligo, and possibly has a protective function to enzymatic degradation in vivo.

Animals↗

Scintilymphangiography with 99 mTc-antimony sulfide colloid in hereditary lymphedema (Nonne-Milroy diseases).

A family of four patients suffering from Nonne-Milroy disease has been examined by pedal scintilymphangiography. Lower limb edema was present in three patients and was bilateral in two instances. Scintilymphangiographic abnormality was invariably present, ranging from almost total obstruction of lymphatic flow to lymphatic pooling. The inguinal, iliac and para-aortic nodes on the affected sides were also noted to be small and few in number. The examination is safe and simple and may be used to distinguish Nonne-Milroy edema from edema due to other causes.

Adult↗

Osteoid-osteoma of the spine with localization aided by 99 mTc-polyphosphate bone scan. Case report.

This is a case report of a 13-year-old boy with an osteoid-osteoma located in the pedicle of the third lumbar vertebra. The lesion could not be visualized on routine roentgenograms but with the use of technetium polyphosphate bone scan as a guide a suggestive bone lesion was found with tomograms. Histologic examination confirmed the diagnosis of osteoid-osteoma. This case illustrates the value of skeletal scanning in occult bone lesions.

Adolescent↗

Pressure-controlled drainage of cerebrospinal fluid: clinical experience with a new type of ventricular catheter (Ventcontrol MTC)and an integrated Piezo-resistive sensor at its tip: technical note.

We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.

Brain Edema↗

Experience with 111-In-chloride scanning in patients with focal defects on 99-mTc-sulfur colloid liver scans.

Thirty-nine patients with focal defects on the technetium liver scan were rescanned using 111-In chloride. Of 20 patients with hepatic malignancy, 11 had positive indium scans. None of the 19 with focal cirrhotic fibrosis had a positive indium scan although 5 of these had primary tumor. Thus, a positive indium scan suggests that the defect is malignant. A negative indium scan is less helpful, failling to distinguish between neoplasm and focal cirrhosis. Positive uptake in an extrahepatic primary neoplasm and negative uptake in the liver suggest that the hepatic lesion is not neoplastic.

Adolescent↗

Application of scintigraphy MDP 99 mTc in the diagnosis of osteoarticular pains of obscure etiology.

The three-phase scintigraphy of bones is useful in detecting disorders of bone tissue perfusion metabolism in patients with the occult etiology of joint pains. The bone scintigraphy with application of MDP plays the main role in the orthopaedic diagnosis. It is of the greatest importance when radiograms are not normal. In spite of application of the other modern methods it is the technique of choice in the early diagnosis.

Adult↗

[The evaluation of 123I-MIBG scintigraphy in medullary thyroid carcinoma (MTC)].

The diagnostic value of 123-I-MIBG (meta-iodobenzylguanidine) scintigraphy was investigated in six patients with recurrence and/or metastatic spread of a medullary thyroid carcinoma. In no case was there MIBG storage in tumor tissue. Thus, our results show that MIBG scintigraphy is not suitable as a screening method either in the primary diagnostics or the follow-up of medullary thyroid carcinoma. If, however, inoperable metastases have been detected by other diagnostic methods, MIBG scintigraphy is indicated in order to test a potential therapeutic application in these patients. In the imaging diagnostics and follow-up of medullary thyroid carcinoma, the examination with 99mTc(V)-DMSA (technetium-99m-dimercaptosuccinate) is markedly superior to MIBG scintigraphy. High-resolution cervical sonography is of major importance in the hands of an experienced examiner.

3-Iodobenzylguanidine↗