Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MR”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Receptor-binding and down-regulatory properties of 22000-Mr human growth hormone and its natural 20000-Mr variant on IM-9 human lymphocytes.

Our earlier binding studies of the 22000- and 20000-Mr variants of human growth hormone (somatotropin) to pregnant-rabbit liver and mammary receptors [Closset, Smal, Gomez & Hennen (1983) Biochem. J. 214, 885-892] suggested that the 20000-Mr variant was a lower-affinity analogue of the 22000-Mr molecule. Since the receptor population in these tissues is not fully characterized, we have now investigated the binding of both variants to the well-characterized and highly specific human-growth-hormone receptor of the human lymphocyte IM-9 cell line. The maximum bindability of radioiodinated 22000- and 22000-Mr to IM-9 cells was 60 and 45% respectively. Both hormone variants have essentially the same binding characteristics: slow association (equilibrium reached in 8-10h at 30 degrees C), poor reversibility ('tight binding'), linear Scatchard plot, same specificity as shown by lack of competition by bovine, porcine or equine growth hormones or human growth hormone-(32-46)-(missing in the 20000-Mr variant),-(1-134)- and -(141-191)-peptides. Both unlabelled hormones inhibit binding of both tracers completely, with the 20000-Mr variant being only half as potent as the 22000-Mr one. The apparent affinity is 2.8 X 10(9)M-1 for the 22000-Mr variant and 1.6 X 10(9)M-1 for the 20000-Mr variant. This decreased affinity of the 20000-Mr variant appears to be due to a lower association rate constant. Concentrations (5 ng/ml) of the two variants that occupy about 15% of the total sites induce a marked down-regulation of the receptors after 18h incubation, but the 20000-Mr variant (50% decrease) has a smaller effect than the 22000-Mr variant (75% decrease). Thus the only consequence of the residues-32-46 deletion in the 20000-Mr variant is a lower association rate and affinity for the IM-9 lymphocyte human-growth-hormone receptor. The close binding characteristics of the two forms suggest that the known differences in their insulin-like effects cannot be explained by differences in the nature of their interaction with the human-growth-hormone receptor.

Binding Sites↗

Feasibility of MR-guided angioplasty of femoral artery stenoses using real-time imaging and intraarterial contrast-enhanced MR angiography.

PURPOSE: To show the feasibility of magnetic resonance (MR) for guided interventional therapy of femoral and popliteal artery stenoses with commercially available materials supported by MR real-time imaging and intraarterial MR angiography. MATERIALS AND METHODS: Three patients (1 female, 2male), suffering from symptomatic arterial occlusive disease with stenoses of the femoral (n = 2) or popliteal (n = 1) arteries were included. Intraarterial digital subtraction angiography was performed in each patient pre- and post-interventionally as standard of reference to quantify stenoses. The degree of the stenoses reached from 71 - 88 %. The MR images were acquired on a 1.5 T MR scanner (Magnetom Sonata; Siemens, Erlangen, Germany). For MR-angiography, a Flash 3D sequence was utilized following injection of 5 mL diluted gadodiamide (Omniscan; Amersham Buchler, Braunschweig, Germany) via the arterial access. Two maximum intensity projections (MIP) were used as road maps and localizer for the interactive positioning of a continuously running 2D-FLASH sequence with a temporal solution of 2 images per second. During the intervention, an MR compatible monitor provided the image display inside the scanner room. Safety guidelines were followed during imaging in the presence of a conductive guidewire. The lesion was crossed by a commercially available balloon catheter (Wanda, Boston Scientific; Ratingen, Germany), which was mounted on a 0.035" guidewire (Terumo; Leuven, Belgium). The visibility was provided by radiopaque markers embedded in the balloon and was improved by injection of 1 mL gadodiamide into the balloon. After dilation, the result was checked by intraarterial MR angiography and catheter angiography. RESULTS: The stenoses could be correctly localized by intraarterial MR angiography. There was complete correlation between intraarterial MR angiography and digital subtraction angiography. The combination of guidewire and balloon was visible and the balloon was placed correctly to cover the entire stenoses. Balloon dilation reduced the degree of stenosis about 45 % on average. A prolonged dilation was necessary in one patient due to a relevant residual stenosis, which was recognized by intraarterial MR angiography. CONCLUSION: MR-guided balloon dilatation of femoral and popliteal artery stenoses supported by real time imaging and intraarterial MR angiography is feasible with commercially available materials in the above mentioned way.

Aged↗

MR-guided and MR-monitored neurosurgical procedures at 1.5 T.

A combined MR suite and operating room (MR-OR) has been developed and extensively assessed for its use in a wide spectrum of therapeutic applications. Equipped with a 1.5 T short bore clinical MR scanner and standard neurosurgical OR equipment, in this MR surgical suite, surgeons can obtain intraoperative planar and volumetric MR images with superior soft tissue contrast and spatial resolution for surgical planning, guidance, and monitoring. Besides MR morphologic imaging capability, blood oxygen level-dependent functional MRI and proton MR spectroscopic imaging have been demonstrated intraoperatively in the same MR-OR to aid in surgical planning and guide tumor resections. A perspective surgical navigation device and remotely operated instrument have been developed and successfully used to assist surgeons in aligning and introducing biopsy needles under fluoroscopic MRI in brain biopsy procedures. Furthermore, surgical complications can be assessed immediately before the closure. There are numerous advantages offered by this unprecedented MR-guided surgical approach, most of which are demonstrated and presented herein. Since 1997, >270 neurosurgical cases (42% brain biopsies, 25% tumor resections, 11% functional neurosurgeries, 10% cyst drainages and shunt placements, and 12% others) have been performed in the MR-OR with a <1% overall complication rate. The tumor recurrence rate for the MR-guided surgical approach is significantly less than that of the conventional one. Exemplary neurosurgical cases that have been performed in the MR-OR suite within the last 24 months are included. Overall, this high magnetic field approach to the MR-guided minimally invasive surgical procedures has been shown to be practical and acceptable to neurosurgeons as well as to neuroradiologists for a wide range of neurosurgical and neuroradiologic applications.

Biopsy, Needle↗

Peripheral vascular disease: blinded study of dedicated calf MR angiography versus standard bolus-chase MR angiography and film hard-copy angiography.

PURPOSE: To compare the accuracy of contrast material-enhanced three-dimensional (3D) dedicated calf magnetic resonance (MR) angiography with that of bolus-chase MR angiography, with conventional angiography as the reference standard, in patients with symptomatic peripheral vascular disease (PVD). MATERIALS AND METHODS: Thirty men with symptomatic PVD were examined. MR angiography was performed at 1.5 T before conventional angiography. MR angiographic examination included 3D contrast-enhanced dedicated calf MR angiography and three-station bolus-chase MR angiography. Two radiologists blinded to conventional angiographic results evaluated the MR angiograms independently. Two angiographers evaluated the conventional angiograms in consensus. Calf artery segments were graded as having 50% or less stenosis, greater than 50% stenosis, or occlusion or as being nondiagnostic. Statistical analyses were performed with paired permutation testing. RESULTS: Analyses of 472 calf segments and 420 pelvic and thigh segments were performed. Of the 472 calf segments, three and 75 segments (reader 1) and seven and 91 segments (reader 2) were graded as nondiagnostic at dedicated calf MR angiography and bolus-chase MR angiography, respectively. Differences in diagnostic grade between the two examinations were significant (P <.001), accounting for within-subject correlations, with a mean estimated difference of -17.1% (95% confidence interval [CI]: -25.8%, -8.4%). In the calf arteries, the dedicated and bolus-chase MR angiographic sequences had diagnostic accuracies, respectively, of 81.5% (reader 1) and 79.1% (reader 2) and of 67.8% (reader 1) and 63.4% (reader 2). The dedicated calf sequence was significantly more accurate than the bolus-chase sequence (P =.001). The point estimate of the difference was 14.7%, with estimated correct diagnosis rates of 80.3% and 65.6% for the dedicated calf and bolus-chase examinations, respectively (95% CI for difference: 4.0%, 25.4%). The diagnostic accuracy of bolus-chase MR angiography at the pelvis-thigh level was slightly higher when it was performed first: 81.9% (reader 1) and 83.8% (reader 2) versus 74.3% (reader 1) and 80.0% (reader 2) when it was performed last. The difference was not significant (P =.21). CONCLUSION: Use of dedicated calf MR angiography led to significantly increased diagnostic accuracy in the calf arteries compared with standard bolus-chase MR angiography. Use of the dual-bolus technique did not jeopardize the diagnostic accuracy in the pelvic and thigh arteries.

Aged↗

Prostate cancer: prediction of extracapsular extension with endorectal MR imaging and three-dimensional proton MR spectroscopic imaging.

PURPOSE: To determine if the addition of three-dimensional (3D) proton magnetic resonance (MR) spectroscopic imaging to endorectal MR imaging helps diagnose extracapsular extension (ECE) of prostate cancer. MATERIALS AND METHODS: Endorectal MR imaging and 3D MR spectroscopic imaging were performed in 53 patients with prostate cancer before radical prostatectomy. MR imaging studies were evaluated by two independent readers unaware of histopathologic findings. The presence of ECE was graded on a five-point scale. At 3D MR spectroscopic imaging, cancer was diagnosed if the ratio of choline plus creatine to citrate was 2 or more SDs above normal. The accuracy of MR imaging alone was compared with that of combined MR imaging and 3D MR spectroscopic imaging, with use of the step-section histopathologic results as the standard of reference. RESULTS: For the less experienced reader, the addition of 3D MR spectroscopic imaging to MR imaging significantly improved accuracy (area under the receiver operating characteristic curve [Az] = 0.75 vs Az = 0.62, P < .05). For the more experienced reader, the addition improved accuracy but not significantly (Az = 0.86 vs Az = 0.78). The addition also reduced interobserver variability (Az = 0.86 vs Az = 0.75). CONCLUSION: The addition of 3D MR spectroscopic imaging to MR imaging improves accuracy for less experienced readers and reduces interobserver variability in the diagnosis of ECE of prostate cancer.

Cross-Sectional Studies↗

Evaluation of the pancreas: a comparison of single thick-slice MR cholangiopancreatography with multiple thin-slice volume reconstruction MR cholangiopancreatography.

OBJECTIVE: The purpose of this study was to assess abilities of single thick-slice MR cholangiopancreatography and multiple thin-slice multiprojection volume reconstruction (MPVR) MR cholangiopancreatography to evaluate diseases in and around the pancreas. SUBJECTS AND METHODS: Eighty-nine patients underwent both single and MPVR MR cholangiopancreatography using a single-shot fast spin-echo technique. Image quality (five-point scale), visualization of the common bile and pancreatic ducts (three-point scale), stenotic, dilatational, or cystic changes of the pancreatic ducts, and other pathologic findings were evaluated. RESULTS: Image quality was high for single and MPVR MR cholangiopancreatography (4.1+/-0.7 and 4.5+/-0.6, respectively). Misregistration was noted in 19 patients with MPVR MR cholangiopancreatography. Ducts on and around the greater duodenal papilla and the common bile duct were revealed better using MPVR than single MR cholangiopancreatography (p < .05). Overall sensitivity, specificity, and accuracy for detection of stenosis of the main pancreatic ducts were 83.3%, 93.6%, and 88.8%, respectively, using single MR cholangiopancreatography and 76.2%, 97.9%, 87.6%, respectively, using MPVR MR cholangiopancreatography. Dilatation of the pancreatic ducts (100%) and cystic changes (n = 17 and n = 19, respectively) were well seen using either single or MPVR MR cholangiopancreatography. Although stenotic changes of the nondilated main pancreatic ducts and their branches were difficult to evaluate using single (62.5% and 14.3%, respectively) or MPVR (43.8% and 21.4%, respectively) MR cholangiopancreatography, single MR cholangiopancreatography better depicted ductal continuity. CONCLUSION: For evaluation of the pancreas, single and MPVR MR cholangiopancreatography provide complementary data; thus, we recommend using a combination of these two MR cholangiopancreatography techniques.

Adult↗

MR imaging of coarctation of the aorta and its postoperative complications in adults: assessment with spin-echo and cine-MR imaging.

To evaluate the ability of ECG-gated spin-echo (SE)-MR imaging vs. cine-MR imaging to assess coarctation of the aorta, 11 patients aged 15-45 years, with known or suspected coarctation of the aorta, and five patients suspected of re-stenosis or postoperative false-aneurysms after coarctation repair were examined by multisection SE-MR imaging and single-section multiphase cine-MR imaging on a 1.0 Tesla device. Aortography was performed in 15, and surgery in 14 of these 16 patients. Qualitatively, the location, severity, and length of the coarctation were shown in all cases with MR imaging, as well as the relationship with the arteries arising from the aortic arch. The respective sensitivities and specificities in the assessment of severity of stenoses were 86% and 100% for SE MR images, and 100% and 100% for cine-MR images. Cine-MR imaging was superior to SE imaging in stenosis diameter assessment with contrast angiography as reference, as well as to identify the site of leakage in cases of postoperative pseudoaneurysm. Pre-stenotic dilation or post-stenotic aneurysm, collateral channels, and associated malformations were better identified on SE images. Quantitatively, a better stenosis diameter correlation was found between cine-MR images and angiography than between SE-MR images and angiography (r=0.99 vs. r=0.78; p=0.001 vs. p=0.004), related to overestimation of stenoses with SE-MR imaging. The use of a combination of spin-echo and cine-MR imaging correlates well with conventional angiographic findings in this small series of patients with coarctation of aorta or postoperative pseudoaneurysmal complications. Cine-MRI can provide anatomic information that is equivalent to angiography for surgical planning.

Adolescent↗

MR-guided joint puncture and real-time MR-assisted contrast media application.

OBJECTIVE: To develop, in MR arthrography of the shoulder joint, an MR-guided technique for localizing the needle puncture and confirming the intracapsular needle-tip position by visualization of the contrast media inflow. MATERIAL AND METHODS: Three unfixed human shoulder specimens were examined on a 1.0 T MR unit. On the basis of MR-compatible markers, the optimal entrance point for puncturing the joint was determined. The precise localization of the needle tip (MR-compatible 0.7-mm needle) in the shoulder joint was determined with rapid localizer GRE sequences in 2 orthogonal planes. To confirm the intracapsular position of the needle tip, diluted Gd-DTPA was applied via a long connecting tube and contrast medium inflow into the joint space was controlled on an LCD screen in real-time MR imaging (local-look technique). RESULTS: MR-compatible markers on the skin allowed the rapid determination of the optimal entrance point for needle puncture. An adequate localization of the intra-articular needle-tip position was possible in all specimens although significant artifacts were present on rapid localizer GRE sequences which resulted in an increase in the apparent width of the needle shaft. Real-time MR imaging of the contrast medium inflow was made possible by the local-look technique and LCD screen on the MR unit and this allowed confirmation of the intracapsular position. CONCLUSION: In MR arthrography of the shoulder, an MR-guided technique in conjunction with the LCD screen and real-time MR imaging would seem to be a practical alternative to conventional fluoroscopic guidance.

Artifacts↗

Localized prostate cancer: effect of hormone deprivation therapy measured by using combined three-dimensional 1H MR spectroscopy and MR imaging: clinicopathologic case-controlled study.

PURPOSE: To determine the accuracy of combined magnetic resonance (MR) imaging and three-dimensional (3D) proton MR spectroscopic imaging in localizing prostate cancer to a sextant of the gland in patients receiving hormone deprivation therapy. MATERIALS AND METHODS: Combined MR imaging/3D MR spectroscopic imaging examinations were performed in 16 hormone-treated patients and 48 nontreated matched control patients before radical prostatectomy and step-section histopathologic analysis. At MR imaging, cancer presence within the peripheral zone was assessed on a per sextant basis by two readers. At 3D MR spectroscopic imaging, cancer was identified by using (choline plus creatine)-to-citrate ratios at cutoff values of 2 and 3 SDs above mean normal peripheral zone values. Data were compared by using receiver operating characteristic analysis. RESULTS: There was no significant difference in the ability of combined MR imaging/3D MR spectroscopic imaging to localize prostate cancer in treated versus control patients. For MR imaging alone, the sensitivity and specificity were 91% and 48% (reader 1) and 75% and 60% (reader 2) in treated patients versus 79% and 60% (reader 1) and 84% and 43% (reader 2) in control patients. For 3D MR spectroscopic imaging alone (>3 SDs cutoff), higher specificity (treated, 80%; controls, 73%) but lower sensitivity (treated, 56%; controls, 53%) was attained. In treated patients, high sensitivity or specificity (up to 92%) was achieved when either or both modalities indicated cancer. CONCLUSION: When performed within 4 months after initiating hormone deprivation therapy, combined MR imaging/3D MR spectroscopic imaging had the same accuracy in localizing prostate cancer as in nontreated patients.

Antineoplastic Agents, Hormonal↗

Prostate cancer tumor volume: measurement with endorectal MR and MR spectroscopic imaging.

PURPOSE: To determine accuracy of magnetic resonance (MR) and three-dimensional (3D) MR spectroscopic imaging in prostate cancer tumor volume measurement. MATERIALS AND METHODS: Endorectal MR and 3D MR spectroscopic imaging were performed in 37 patients before radical prostatectomy. Two independent readers recorded peripheral zone tumor nodule location and volume. Results were analyzed with step-section histopathologic tumor localization and volume measurement as the standard. Accuracy of tumor volume measurement was assessed with the Pearson correlation coefficient. P values were calculated with a random effects model. Bland-Altman regression analysis was used to evaluate systematic bias between tumor volumes measured with MR imaging and true tumor volumes. Analyses were performed for all nodules and nodules greater than 0.50 cm(3). RESULTS: Mean volume of peripheral zone tumor nodules (n = 51) was 0.79 cm(3) (range, 0.02-3.70 cm(3)). Two readers detected 20 (65%) and 23 (74%) of 31 peripheral zone tumor nodules greater than 0.50 cm(3). For these nodules, measurements of tumor volume with MR imaging, 3D MR spectroscopic imaging, and a combination of both were all positively correlated with histopathologic volume (Pearson correlation coefficients of 0.49, 0.59, and 0.55, respectively); only measurements with 3D MR spectroscopic imaging and a combination of MR and 3D MR spectroscopic imaging demonstrated statistical significance (P <.05). Tumor volume estimation with all three methods was more accurate for higher tumor volumes. CONCLUSION: Addition of 3D MR spectroscopic imaging to MR imaging increases overall accuracy of prostate cancer tumor volume measurement, although measurement variability limits consistent quantitative tumor volume estimation, particularly for small tumors.

Adult↗

Internal derangement of the wrist: indirect MR arthrography versus unenhanced MR imaging.

PURPOSE: To compare indirect magnetic resonance (MR) arthrography with unenhanced MR imaging of the wrist for evaluation of the central disk of the triangular fibrocartilage complex (TFCC) and the scapholunate and lunotriquetral interosseous ligaments. MATERIALS AND METHODS: Eighty-six wrists were evaluated at MR imaging (41 indirect MR arthrography and 45 unenhanced MR imaging examinations). Three musculoskeletal radiologists independently evaluated the central disk of the TFCC and scapholunate and lunotriquetral ligaments and compared the results with those of wrist arthroscopy. Sensitivity and specificity were calculated for each of the readers, and the means were obtained. Sensitivities and specificities were compared with the Student t test. RESULTS: Thirty-three tears of the central disk of the TFCC and 13 scapholunate and 18 lunotriquetral ligament tears were identified at arthroscopy. Sensitivities and specificities were 54%-73% and 83%-91%, respectively, in the evaluation of the central disk of the TFCC, with no significant difference between indirect MR arthrography (P =.666) and unenhanced MR imaging (P =.559). Sensitivities and specificities in the evaluation of the scapholunate ligament were 38%-69% and 75%-99%, respectively, with a significant improvement in sensitivity at indirect MR arthrography (P =.017) and no significant difference in specificity (P =.876). Sensitivities in the evaluation of the lunotriquetral ligament were poor, 0%-22%, though the specificities were 88%-99%, with no significant difference between indirect MR arthrography and unenhanced MR imaging (P =.592 and P =.354, respectively, for sensitivity and specificity. CONCLUSION: Indirect MR arthrography significantly improves sensitivity in the evaluation of the scapholunate ligament when compared with unenhanced MR imaging of the wrist but does not significantly improve the ability to evaluate the central disk of the TFCC or the lunotriquetral ligament.

Adult↗

Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging.

PURPOSE: To prospectively determine the accuracies of T2-weighted magnetic resonance (MR) imaging, dynamic contrast material-enhanced MR imaging, and quantitative three-dimensional (3D) proton MR spectroscopic imaging of the entire prostate for prostate cancer localization, with whole-mount histopathologic section findings as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained from all patients. Thirty-four consecutive men with a mean age of 60 years and a mean prostate-specific antigen level of 8 ng/mL were examined. The median biopsy Gleason score was 6. T2-weighted MR imaging, dynamic contrast-enhanced MR imaging, and 3D MR spectroscopic imaging were performed, and on the basis of the image data, two readers with different levels of experience recorded the location of the suspicious peripheral zone and central gland tumor nodules on each of 14 standardized regions of interest (ROIs) in the prostate. The degree of diagnostic confidence for each ROI was recorded on a five-point scale. Localization accuracy and ROI-based receiver operating characteristic (ROC) curves were calculated. RESULTS: For both readers, areas under the ROC curve for T2-weighted MR, dynamic contrast-enhanced MR, and 3D MR spectroscopic imaging were 0.68, 0.91, and 0.80, respectively. Reader accuracy in tumor localization with dynamic contrast-enhanced imaging was significantly better than that with quantitative spectroscopic imaging (P < .01). Reader accuracy in tumor localization with both dynamic contrast-enhanced imaging and spectroscopic imaging was significantly better than that with T2-weighted imaging (P < .01). CONCLUSION: Compared with use of T2-weighted MR imaging, use of dynamic contrast-enhanced MR imaging and 3D MR spectroscopic imaging facilitated significantly improved accuracy in prostate cancer localization.

Aged↗

Imaging of osseous and cartilaginous intraarticular bodies in the knee: comparison of MR imaging and MR arthrography with CT and CT arthrography in cadavers.

PURPOSE: To compare magnetic resonance (MR) imaging and MR arthrography with computed tomography (CT) and CT arthrography in the detection of intraarticular bodies in the knee. MATERIALS AND METHODS: Cuboid (3- or 6-mm-long sides) osseous and cartilaginous bodies were implanted in 16 cadaveric knee specimens. MR imaging was performed with T1-weighted spin-echo (SE), T2-weighted SE, proton-density-weighted SE, gradient recalled acquisition in the steady state (GRASS), and spoiled GRASS sequences. MR arthrography was performed in two phases with saline and 2 mmol/L gadopentetate dimeglumine. CT and CT arthrography were performed in the transaxial plane. RESULTS: MR arthrography yielded the highest accuracy for the detection of osseous and cartilaginous bodies combined (92%) and was significantly (P < .01) better than MR imaging (57%-70%), CT arthrography (80%), and CT (74%). Accuracy of CT arthrography was significantly better than that of MR imaging and that of CT. Accuracy of saline-enhanced MR arthrography was significantly inferior (P < .001) to that of gadolinium-enhanced MR arthrography. CONCLUSION: MR arthrography is the best imaging technique for detection of individual intraarticular bodies. CT arthrography is the second most accurate method. Spoiled GRASS and T2-weighted SE sequences are the most accurate at MR imaging. The presence of intraarticular fluid and performance of saline-enhanced MR arthrography improve detectability of intraarticular bodies.

Arthrography↗

Localizing prostate cancer in the presence of postbiopsy changes on MR images: role of proton MR spectroscopic imaging.

PURPOSE: To assess whether magnetic resonance (MR) spectroscopic imaging with MR imaging can improve prostate cancer localization in postbiopsy hemorrhage cases. MATERIALS AND METHODS: Records of 175 patients with prostate cancer were retrospectively reviewed; 42 patients (135 hemorrhagic sites) had spatially correlated biopsy data. Patients underwent both phased-array coil-endorectal coil MR imaging and three-dimensional MR spectroscopic imaging within 180 days after transrectal ultrasound (US)-guided biopsy. High-signal-intensity hemorrhage on T1-weighted images and corresponding high- or low-signal-intensity areas on T2-weighted images and the metabolic ratio (choline + creatine)/citrate were recorded. Cancer was identified as a low-signal-intensity area at T2-weighted MR imaging or a metabolite ratio greater than 3 standard deviations above normal at MR spectroscopic imaging. MR imaging, spectroscopic, and biopsy findings were compared. RESULTS: Forty-nine patients had postbiopsy hemorrhage. On T2-weighted images, a higher (P < .01) percentage of hemorrhagic sites demonstrated low signal intensity (80% [108 of 135 sites]), which is similar to the signal intensity seen with cancer. The addition of MR spectroscopic imaging to MR imaging resulted in a significant increase (P < .01) in the accuracy (52% to 75%) and specificity (26% to 66%) of tumor detection. CONCLUSION: The addition of MR spectroscopic imaging to MR imaging significantly improves the ability to determine the presence of prostate cancer and spatial extent when postbiopsy changes hinder interpretation with MR imaging alone.

Aged↗

Systemic lupus erythematosus: brain MR imaging and single-voxel hydrogen 1 MR spectroscopy.

PURPOSE: To evaluate the usefulness of magnetic resonance (MR) imaging and hydrogen 1 MR spectroscopy in the detection of brain involvement in patients with systemic lupus erythematosus (SLE) with or without neuropsychiatric symptoms. MATERIALS AND METHODS: Twenty-six patients who had SLE with (n = 17) or without (n = 9) neuropsychiatric symptoms were examined at MR imaging and (1)H MR spectroscopy. The voxel was placed in the basal ganglia and peritrigonal white matter. Eight healthy volunteers were included. RESULTS: Five of nine patients with major neuropsychiatric symptoms and one of eight patients with minor neuropsychiatric symptoms had abnormal MR imaging findings. (1)H MR spectroscopy showed a significantly decreased N:-acetylaspartate-creatine (Cr) ratio in the basal ganglia and an increased choline-Cr ratio in the peritrigonal white matter in patients with major symptoms compared with those with minor symptoms, those without symptoms, and healthy control subjects. Among patients with major symptoms, there was no difference in metabolite ratios between those with and those without abnormal MR imaging findings. Among patients with normal MR imaging findings, abnormal spectral changes were observed only in those with major neuropsychiatric symptoms. In patients without neuropsychiatric symptoms, results of (1)H MR spectroscopy and MR imaging were normal. CONCLUSION: In patients with SLE, (1)H MR spectroscopic findings seem to reflect the cerebral metabolic disturbance related to the severity of the neuropsychiatric symptoms and are not related to the presence of abnormal MR imaging findings.

Adolescent↗

Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits.

PURPOSE: To develop a technique for intravascular magnetic resonance (MR)-guided balloon angioplasty with use of an MR imaging guide wire. MATERIALS AND METHODS: An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use with interventional devices. Laparotomy was performed in eight rabbits, and a dilatable stenosis was created at the upper abdominal aorta. Balloon angioplasty, validated at pre- and postoperative MR aortography with renal contrast enhancement was performed by using a 1.5-T MR unit with a fast spoiled gradient-echo pulse sequence, short repetition and echo times, and a rate of three frames per second. RESULTS: During MR tracking, the entire length of the MR imaging guide wire was always visible as a band of high signal intensity. In all cases, the MR imaging guide wires were passed through the aortic stenoses dilated by means of balloon inflation. Before balloon angioplasty, flow in the aorta distal to the stenosis was decreased, which caused mild contrast enhancement in each kidney. After balloon angioplasty, distal flow was restored, resulting in substantial renal enhancement. CONCLUSION: The MR imaging guide wire is a potential tool for use in endovascular interventional MR imaging.

Angioplasty, Balloon↗

Measurement of anal sphincter muscles: endoanal US, endoanal MR imaging, or phased-array MR imaging? A study with healthy volunteers.

PURPOSE: To compare endoanal ultrasonography (US), endoanal magnetic resonance (MR) imaging, and phased-array MR imaging for anal sphincter muscle measurement. MATERIALS AND METHODS: Sixty healthy volunteers underwent 1.5-T phased-array MR, endoanal MR, and endoanal US examinations. Sphincter muscle thicknesses were measured. Measurement reliability was analyzed, and correlations among the imaging methods were calculated. Multivariate analysis was performed to assess the influence of age, weight, height, sex, parity, and obstetric trauma on sphincter dimensions. RESULTS: Both MR methods had good reliability for measurements of all sphincter components, whereas endoanal US was reliable for internal sphincter measurement only. There was little correlation between the techniques, except between the two MR techniques, with a strong correlation for total sphincter and perineal body thickness. The internal sphincter thickened significantly (P =.002) with age at endoanal US and endoanal MR imaging but not at phased-array MR imaging. There were small sex-based differences in sphincter muscle measurements at phased-array MR imaging only. CONCLUSION: Endoanal US enables reliable measurement of only internal sphincter thickness, whereas both MR imaging methods enable reliable measurement of all sphincter components. Sphincter measurement with phased-array MR imaging is as reliable as that with endoanal MR imaging.

Adult↗

Intracranial dural arteriovenous fistulas: evaluation with combined 3D time-of-flight MR angiography and MR digital subtraction angiography.

OBJECTIVE: The purpose of this study was to compare the diagnostic utility of 3D time-of-flight (TOF) MR angiography and MR digital subtraction angiography in patients with angiographically proven moderate- to high-flow intracranial dural arteriovenous fistula. MATERIALS AND METHODS: Two neuroradiologists, unaware of patients' histories and angiographic findings, retrospectively reviewed 17 MR angiograms with 3D TOF MR angiography and MR digital subtraction angiography in 15 patients with dural arteriovenous fistula and also reviewed 35 MR angiograms in control patients without findings of dural arteriovenous fistula on angiography. Disagreements were resolved by consensus. RESULTS: In patients with dural arteriovenous fistula, source images of 3D TOF MR angiography showed two abnormal findings: multiple high-intensity curvilinear or nodular structures adjacent to the sinus wall and high-intensity areas in the venous sinus. Findings of multiple high-intensity structures adjacent to the sinus wall were observed in all cases of dural arteriovenous fistula. Findings of high-intensity areas in the venous sinus were observed in 13 of 17 cases of dural arteriovenous fistula. Findings of multiple high-intensity structures adjacent to the sinus wall were not observed in any control subjects. Findings of high-intensity areas within the venous sinus were observed in five of 35 control subjects. Findings of MR digital subtraction angiography showed early filling of the venous sinus, suggestive of dural arteriovenous fistula, in 13 of 15 patients with dural arteriovenous fistula. Sensitivity and specificity of multiple high-intensity structures adjacent to the sinus wall, high-intensity areas in the venous sinus, and early filling of the venous sinus were 100% and 100%, 76% and 86%, and 87% and 100%, respectively. Although 3D TOF MR angiography failed to show the findings of retrograde cortical venous drainage and venous sinus occlusion, MR digital subtraction angiography clearly showed both findings in all five subjects. CONCLUSION: A protocol including both 3D TOF MR angiography (source images) and MR digital subtraction angiography allowed the diagnosis of moderate- to high-flow dural arteriovenous fistula. In addition, cortical venous drainage was reliably noted in a small subset of patients.

Adult↗