Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Hydrogen magnetic resonance spectroscopy follow-up after radiation therapy of human brain cancer. Unexpected inverse correlation between the changes in tumor choline level and post-gadolinium magnetic resonance imaging contrast.

RATIONALE AND OBJECTIVES: The anatomic and metabolic changes in human brain tumors treated by radiation therapy were compared using gadolinium-enhanced magnetic resonance imaging and hydrogen (1H) magnetic resonance spectroscopy. The study was intended to assess the potential of 1H magnetic resonance spectroscopy in monitoring response to therapy. METHODS: Thirteen cases of brain cancer treated by radiation therapy were examined by 1H magnetic resonance spectroscopy and gadolinium-enhanced T1-weighted magnetic resonance imaging and reexamined at 2-month intervals. RESULTS: Follow-up after radiation therapy showed changes in post-gadolinium magnetic resonance imaging contrast that are inversely correlated with the changes in choline level (r = -0.69, P < 0.00001) and in tumor volume (r = -0.35, P < 0.05). CONCLUSIONS: The choline loss in tumors gaining post-gadolinium magnetic resonance imaging contrast after therapy is unexpected in view of previously reported correlation between the two in untreated metastatic brain tumors. Indicated is the use of 1H magnetic resonance spectroscopy to discriminate enhancing brain tumors with a high content of vital tumor cells (high choline) from tumors, combining decreased cell density with increased interstitial space (low choline).

Aspartic Acid↗

Effects of magnetic resonance imaging on implantable permanent magnets.

Implantable permanent magnets are increasingly used in devices for otolaryngologic applications. It is likely that at least some of the patients with implanted magnets will be in need of magnetic resonance imaging (MRI). The effect of an MRI scan on the magnetic properties of implanted permanent magnets has not been previously demonstrated. Some of the basic concepts and descriptive terminology used in industry regarding permanent magnets are reviewed. Experiments presented show that the MRI scan is capable of demagnetizing permanent magnets. A case history is also presented that demonstrates demagnetizing of an implanted Audiant magnet by an MRI scan.

Hearing Aids↗

Effect of magnetic vs sham-magnetic insoles on plantar heel pain: a randomized controlled trial.

CONTEXT: Despite anecdotal reports, rigorous scientific evidence of the effectiveness of magnetic insoles for the pain of plantar fasciitis is lacking. OBJECTIVE: To determine whether magnetic insoles provide greater subjective improvement for treatment of plantar heel pain compared with identical nonmagnetized insoles. DESIGN, SETTING, AND PARTICIPANTS: Randomized, double-blind, placebo-controlled trial conducted from February 12, 2001, to November 9, 2001, of a volunteer sample of 101 adults with diagnoses of plantar heel pain for at least 30 days from a multispecialty group practice clinic in Rochester, Minn. Daily pain diaries were kept for 8 weeks. INTERVENTIONS: Cushioned insoles, with either active bipolar magnets or sham magnets, which were worn daily by the participants for 8 weeks. MAIN OUTCOME MEASURES: Reported average daily foot pain (by metered visual analog scale [VAS] and by categorical response of change from baseline) at 4 and 8 weeks, and impact of insoles on employment performance and enjoyment. RESULTS: No significant between-group differences were found on any outcome variables studied when comparing active vs sham magnets. Both the nonmagnetic and magnetic groups reported significant improvements in morning foot pain intensity, with mean (SD) VAS scores improving from 6.9 (2.3) and 6.7 (2.0), respectively, at baseline to 3.9 (2.6) for each group at 8 weeks (P =.94). At 8 weeks, 33% of the nonmagnetic group and 35% of the magnetic group reported being all or mostly better (P =.78). At baseline, foot pain interfered moderately with participants' employment enjoyment (mean VAS, 4.2) and improved in both groups by 8 weeks (1.3 and 1.5, respectively; P =.68). CONCLUSION: Static bipolar magnets embedded in cushioned shoe insoles do not provide additional benefit for subjective plantar heel pain reduction when compared with nonmagnetic insoles.

Adult↗

Effects of coil orientation and magnetic field shield on transcranial magnetic stimulation in cats.

To obtain suitable stimulus conditions for transcranial magnetic stimulation, the evoked compound muscle action potential (ECMAP), evoked spinal cord potential (ESCP), and magnetic and electric fields were analyzed in cats with and without the use of a magnetic field shield. Cats were stimulated using a figure 8 magnetic coil placed on the cranium above the motor cortex. The maximum ECMAP amplitude was recorded when the electric current in the coil was in the mediolateral direction, regardless of whether a magnetic shield with a 5 x 5 cm window was used. ECMAP and ESCP thresholds were reduced when magnetic shielding was in place. Due to the edge effect, the strengths of the magnetic and electric fields were highest in the brainstem area, which is an inhomogeneous volume conductor of the cat's cranium. A large induced electric field directed caudally elicited ECMAP and ESCP responses effectively when a magnetic shield with a 5 x 5 cm window was in place.

Action Potentials↗

Growth of human cultured cells exposed to a non-homogeneous static magnetic field generated by Sm-Co magnets.

A static magnetic field, with a strong spatial gradient, was established on the surface of cell culture dishes by use of a gilded iron needle set vertically above an Sm-Co magnet. The calculated magnetic flux density was more than 1.5 T at the center of the needle tip, and the products of the flux density and its gradient were about 200 and 60 T2/m at distances of 0.1 and 0.3 mm, respectively, from the center. The DNA content, DNA synthesis and labeling index of cultured cells located within 0.1 mm from the center of the needle, and the growth rate of cells located within 0.3 mm from the center, were measured. HeLa cells grew at a normal rate for 96 h in the magnetic field and showed no significant change in shape, detectable by scanning electron microscopy. The growth of HeLa cells was not influenced by exposure to the magnetic field. Similarly, exposure for 48 h to the magnetic field had no effect on growth of normal human gingival fibroblasts (Gin-1). The DNA content, assayed by microfluorometry of the nuclei of both types of cells stained by the Feulgen reaction, was not significantly different from that of controls. Moreover, exposure to the magnetic field had no effect on DNA synthesis or the labeling index of HeLa cells assayed by autoradiography of incorporated [3H]thymidine. It is concluded that a non-homogeneous magnetic field of the intensity and the gradient used in this study does not significantly influence the growth of HeLa cells or Gin-1 cells.

Cells, Cultured↗

Magnetic Marker Monitoring: An application of biomagnetic measurement instrumentation and principles for the determination of the gastrointestinal behavior of magnetically marked solid dosage forms.

Magnetic Marker Monitoring offers an alternative to investigate the behavior of solid dosage forms in the organs of the gastrointestinal tract without the need to apply radiation. For Magnetic Marker Monitoring, the dosage form is marked as a permanent magnetic dipole by the incorporation of small amounts of ferromagnetic material, as for example the colorant black iron oxide, and subsequent magnetization. Thereby, the dosage form is labeled as the source of a well defined magnetic field, which can be measured using a measurement technique that is established for biomagnetic investigations. Using the established concepts for magnetic source localization, the three dimensional localization and orientation as well as the strength of the magnetic source can be reconstructed from these magnetic measurement data as a function of time. Furthermore, it is possible to gain quantitative information on the disintegration of dosage forms in vivo. Examples are given for results obtained concerning the esophageal transit, the gastric and the intestinal behavior of capsules and tablets.

Capsules↗

Magnetic split-flow thin fractionation of magnetically susceptible particles.

We recently built a magnetic separation system to extend the applications of split-flow thin (SPLITT) fractionation to magnetically susceptible particles. Here, we characterize the magnetic SPLITT system using magnetically susceptible particles and ion-labeled particles. The flow axis of separation channel was orientated parallel and perpendicular to gravitational forces to exclude and include, respectively, gravitational effects on separation. Both operating modes were used to test the theory experimentally, with emphasis on the parallel mode. The magnetic susceptibilities of carrier and ion-labeled particles were varied, and various ion-labeled and unlabeled particles were studied experimentally, resulting in successful separation of labeled particles, yeasts, and cells from unlabeled ones. The minimal difference in magnetic susceptibility (delta(chi)) required for complete particle separation was about 1.75 x 10(-5) [cgs], corresponding to about 10(9) labeling ions per particle in this study. The throughput was around 7.2 x 10(8) particles/h using the present setup. Magnetic SPLITT fractionation shows good potential for use in obtaining particles magnetic susceptibilities from a simple theoretical treatment.

Ions↗

Acyclovir serum concentrations following peroral administration of magnetic depot tablets and the influence of extracorporal magnets to control gastrointestinal transit.

In the present investigations peroral acyclovir depot tablets with internal magnets were developed. An extracorporal magnet was used to prolong the gastric residence times of the dosage forms and to influence the duration of absorption of acyclovir. The magnetic depot tablets contained 200 mg acyclovir. In a three-way cross-over in vivo study with five healthy male subjects, the plasma concentration-time profiles of acyclovir were determined. The acyclovir plasma concentrations following peroral administration of magnetic depot tablets in the presence and absence of an extracorporal magnet were determined. A commercially available immediate release preparation was used as a reference preparation. In the presence of an extracorporal magnet which was placed in the stomach region, the plasma concentrations of acyclovir were significantly higher after 7, 8, 10 and 12 h (P<0.05, U-test, Wilcoxon, Mann-Whitney). The mean area under the plasma concentration-time-curve (AUC0-24h), in the presence of the extracorporal magnet was 2802.7 ngh/ml. Without the extracorporal magnet a mean AUC0-24h of 1598.8 ngh/ml was achieved. Computer simulations were carried out to show the influence of the gastric residence time of acyclovir depot preparations on the plasma concentration-time profiles of acyclovir.

Acyclovir↗

Safety of the magnetic field generated by a neuronal magnetic stimulator: evaluation of possible mutagenic effects.

OBJECTIVE: The possible mutagenicity of a magnetic stimulus was checked using the Ames test with Salmonella typhimurium TA98 and TA100 as tester strains. METHODS: Samples of these bacteria were exposed to a pulsed magnetic field, on the order of 1 T. The magnetic pulses were generated by a neuronal magnetic stimulator with a flat coil. The magnetic stimulus was a continuous sequence of slightly damped half sinusoids at a rate of 5 pulses/s. Exposure times were 2-5 and 15 min. Exposure position was such as to maximise the magnetic field and minimise the induced electric field. Room temperature was maintained at 28.5 +/- 0.5 degrees C and the temperature was measured inside the samples. RESULTS: None of the exposure conditions showed any increase in mutation in either of the two bacterial strains. CONCLUSIONS: These results are discussed in comparison with effects found in the literature. The magnetic stimulation used under the conditions of this study does not appear to have mutagenic effects. This does not apply to cases where both strong electric and magnetic fields are present.

Electric Stimulation↗

'Fixed-axis' magnetic orientation by an amphibian: non-shoreward-directed compass orientation, misdirected homing or positioning a magnetite-based map detector in a consistent alignment relative to the magnetic field?

Experiments were carried out to investigate the earlier prediction that prolonged exposure to long-wavelength (>500 nm) light would eliminate homing orientation by male Eastern red-spotted newts Notophthalmus viridescens. As in previous experiments, controls held in outdoor tanks under natural lighting conditions and tested in a visually uniform indoor arena under full-spectrum light were homeward oriented. As predicted, however, newts held under long-wavelength light and tested under either full-spectrum or long-wavelength light (>500 nm) failed to show consistent homeward orientation. The newts also did not orient with respect to the shore directions in the outdoor tanks in which they were held prior to testing. Unexpectedly, however, the newts exhibited bimodal orientation along a more-or-less 'fixed' north-northeast-south-southwest magnetic axis. The orientation exhibited by newts tested under full-spectrum light was indistinguishable from that of newts tested under long-wavelength light, although these two wavelength conditions have previously been shown to differentially affect both shoreward compass orientation and homing orientation. To investigate the possibility that the 'fixed-axis' response of the newts was mediated by a magnetoreception mechanism involving single-domain particles of magnetite, natural remanent magnetism (NRM) was measured from a subset of the newts. The distribution of NRM alignments with respect to the head-body axis of the newts was indistinguishable from random. Furthermore, there was no consistent relationship between the NRM of individual newts and their directional response in the overall sample. However, under full-spectrum, but not long-wavelength, light, the alignment of the NRM when the newts reached the 20 cm radius criterion circle in the indoor testing arena (estimated by adding the NRM alignment measured from each newt to its magnetic bearing) was non-randomly distributed. These findings are consistent with the earlier suggestion that homing newts use the light-dependent magnetic compass to align a magnetite-based 'map detector' when obtaining the precise measurements necessary to derive map information from the magnetic field. However, aligning the putative map detector does not explain the fixed-axis response of newts tested under long-wavelength light. Preliminary evidence suggests that, in the absence of reliable directional information from the magnetic compass (caused by the 90 degrees rotation of the response of the magnetic compass under long-wavelength light), newts may resort to a systematic sampling strategy to identify alignment(s) of the map detector that yields reliable magnetic field measurements.

Animals↗

Biomedical applications of magnetic fluids. i. Magnetic guidance of ferro-colloid-entrapped albumin microsphere for site specific drug delivery in vivo.

Magnetic guidance of magnetic albumin microsphere for site specific drug delivery was investigated in vivo. After intravenous injection in mice, magnetic microspheres localized in the site (lung) at which two permanent magnets were placed. Injection into the renal artery in rats also indicated that the microspheres were concentrated at the kidney by a magnetic field. When magnet was not applied, however, the microspheres were concentrated mainly in the liver. Such preferential localization by magnetic means suggested that magnetic albumin microspheres could become effective drug carriers with site specificity for the delivery of chemotherapeutic agents in cancer therapy.

Albumins↗

Removal of intralenticular magnetic foreign bodies with intraocular magnet.

PURPOSE: To investigate the possibility of conservation of the lens after removal of intralenticular magnetic foreign bodies with intraocular magnet. METHODS: Intralenticular magnetic foreign bodies of 15 patients were removed by using an intraocular magnet. The lens of each injury eye was conserved. Follow-up observation of these cases ranged from one to four years. RESULTS: The intralenticular magnetic foreign bodies of 15 patients were successfully removed. The lens of each injury eye was conserved and the transparence of the lens was properly maintained. Sizes of these foreign bodies were measured, ranging from 0.3 mm to 3 mm in diameter. The follow-up observation showed that the corrected visual acuity of 14 cases was not changed after operation. CONCLUSIONS: The intraocular magnet is very helpful for removal of magnetic foreign bodies from the transparent lens. This magnet allows removing of the foreign body by the surgeon and no damage to the lens was induced during the operation. Thus, maintenance of visual acuity of most of the patients can be achieved.

Accidents, Occupational↗

[Studies on magnetic responsiveness and renal embolization with magnetic microspheres in dogs].

The responsiveness and transcatheter embolization with magnetic gelatin microspheres (MG-ms) in dog kidney were reported. In experiments with magnet using a constant flow apparatus such as roller pump, the percent retention was determined by counting the carrier retained by the magnetic field and divided by the total starting counts. Factors influencing the percent retention of MG-ms include: velocity of medium flow, magnetic field intensity, alpha-Fe2O3 content in the MG-ms, viscosity of the medium and so on. Transcatheter embolization with MG-ms (10-30 microns) was performed under external magnet control in dog kidney. The result of angiogram and histological section showed that the MG-ms were in the arteries, arterioles, and glomerular capillaries with no adverse reactions. The embolized effect with magnet field was more prominent than the group without magnet field. These results show that the MG-ms is a promising embolic agent for treatment of renal cancer under external magnet control.

Animals↗

Metabolic changes after repetitive transcranial magnetic stimulation (rTMS) of the left prefrontal cortex: a sham-controlled proton magnetic resonance spectroscopy (1H MRS) study of healthy brain.

Rapid transcranial magnetic stimulation is being increasingly used in the treatment of psychiatric disorders, especially major depression. However, its mechanisms of action are still unclear. The aim of this study was to assess metabolic changes by proton magnetic resonance spectroscopy following high-frequency rapid transcranial magnetic stimulation (20 Hz), both immediately after a single session and 24 h after a series of five consecutive sessions. Twelve healthy volunteers were enrolled in a prospective single-blind, randomized study [sham (n = 5) vs. real (n = 7)]. Three brain regions were investigated (right, left dorsolateral prefrontal cortex, left anterior cingulate cortex). A single as well as a series of consecutive rapid transcranial magnetic stimulations affected cortical glutamate/glutamine levels. These effects were present not only close to the stimulation site (left dorsolateral prefrontal cortex), but also in remote (right dorsolateral prefrontal cortex, left cingulate cortex) brain regions. Remarkably, the observed changes in glutamate/glutamine levels were dependent on the pre-transcranial magnetic stimulation glutamate/glutamine concentration, i.e. the lower the pre-stimulation glutamate/glutamine level, the higher the glutamate/glutamine increase observed after short- or long-term stimulation (5 days). In general, the treatment was well tolerated and no serious side-effects were reported. Neither transient mood changes nor significant differences in the outcome of a series of neuropsychological test batteries after real or sham transcranial magnetic stimulation occurred in our experiment. In summary, these data indicate that rapid transcranial magnetic stimulation may act via stimulation of glutamatergic prefrontal neurons.

Adult↗

Crystal refinement and magnetic structure of KNi4(PO4)3: a novel example of three interacting magnetic sub-lattices.

KNi(4)(PO(4))(3) has been synthesised following a method previously reported by some of us and studied on the basis of magnetization and neutron powder diffraction (NPD) data. Magnetization measurements suggest the coexistence of ferromagnetic (FM) and antiferromagnetic (AFM) interactions: magnetization versus magnetic field curves present a remanent magnetization of around 2.15 micro(B) at T=2 K. The magnetic structure of the KNi(4)(PO(4))(3) has been determined at low temperature from the NPD data. These measurements show that there are three magnetic sub-lattices of Ni(2+) ions, which interact through common oxygen or phosphate groups, giving rise to FM and AFM couplings. The resulting interactions are FM in nature. Such a complex behaviour could provide an interesting model to analyse magnetic interactions in more condensed systems, such in mixed metal oxides.

Journal Article↗

Destabilizing effect of time-dependent oblique magnetic field on magnetic fluids streaming in porous media.

The present work studies Kelvin-Helmholtz waves propagating between two magnetic fluids. The system is composed of two semi-infinite magnetic fluids streaming throughout porous media. The system is influenced by an oblique magnetic field. The solution of the linearized equations of motion under the boundary conditions leads to deriving the Mathieu equation governing the interfacial displacement and having complex coefficients. The stability criteria are discussed theoretically and numerically, from which stability diagrams are obtained. Regions of stability and instability are identified for the magnetic fields versus the wavenumber. It is found that the increase of the fluid density ratio, the fluid velocity ratio, the upper viscosity, and the lower porous permeability play a stabilizing role in the stability behavior in the presence of an oscillating vertical magnetic field or in the presence of an oscillating tangential magnetic field. The increase of the fluid viscosity plays a stabilizing role and can be used to retard the destabilizing influence for the vertical magnetic field. Dual roles are observed for the fluid velocity in the stability criteria. It is found that the field frequency plays against the constant part for the magnetic field.

Journal Article↗

Investigation of magnetic fluids by ultrasonic and magnetic methods

The influence of magnetic field on the acoustic and magnetic properties of magnetic liquids is discussed. By fitting the curve of Taketomi's theory to the experimental data of the anisotropy of ultrasonic attenuation, the values of quantities describing the structure of magnetic liquids have been determined. Moreover, the dependence of magnetic susceptibility on frequency has been measured. It shows that two processes of magnetization, based on the mechanisms proposed by Brown and Neel, contribute to the magnetization of the magnetic liquid.

Journal Article↗

Magnetophoretic velocimetry of manganese(II) in a single microdroplet in a flow system under a high gradient magnetic field generated with a superconducting magnet.

An experimental system for magnetophoretic velocimetry, which could determine the volume magnetic susceptibility of a single particle dispersed in a liquid phase from a magnetophoretic velocity, has been developed. A micrometer-sized high-gradient magnetic field could be generated in a capillary by a pair of iron pole pieces in a superconducting magnet (10 T). The magnetophoretic behavior of a single particle in a capillary flow system was investigated under the inhomogeneous magnetic field. From the magnetophoretic velocity of a polystyrene latex particle dispersed in a MnCl2 aqueous solution, the product of the magnetic flux density and the gradient, B(dB/dx), was determined as a function of the position along the capillary. The maximum value of B(dB/dx) was 4.7 x 10(4) T2 m(-1), which was approximately 100 times higher than that obtained by two Nd-Fe-B permanent magnets (0.4 T). Organic droplets extracting manganese(II) with 2-thenoyltrifluoroacetone and tri-n-octylphosphine oxide from MnCl2 solution were used as test samples. The difference of the volume magnetic susceptibility between the droplet and the medium could be determined from the magnetophoretic velocity. This method allowed us to continuously measure a volume magnetic susceptibility of 10-6 level for a picoliter droplet and to determine manganese(II) in the single droplet at the attomole level.

Journal Article↗