Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Iud”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Immunologic aspects of IUD action.

Embryo implantation has been demonstrated to depend on specific lymphocyte populations within the uterine cavity. Intrauterine devices (IUD) exert their contraceptive action by prevention of embryo implantation via presently still unknown mechanisms. Therefore, mononuclear cell populations from mice uteri which either contained silastic or copper (Cu) IUD fragments or were sham-operated were evaluated, utilizing monoclonal antibodies against specific cell markers. Uterine horns, bearing IUD fragments, were significantly heavier than sham-operated horns. In Cu-IUD animals this effect extended even into the non-treated contralateral horn. The total number of lymphoid cells in IUD-bearing horns was significantly higher than in sham-operated horns. This observation was also made in non-treated contralateral Cu-IUD horns but not in contralateral horns of silastic-IUD-treated animals. Significant differences in percentages as well as absolute number of various lymphoid cell populations were noted between IUD-treated and sham-operated animals. Again, the effect was more pronounced in Cu-IUD-treated animals and extended in those animals into the contralateral horn. IUD-containing horns also demonstrated a significantly increased number of mast cells, with Cu-IUDs again resulting in a significantly more pronounced effect in both treated and contralateral horns. Sham-operated mice achieved a 67% pregnancy rate in both uterine horns. In contrast, IUD-treated animals demonstrated a significantly reduced pregnancy rate with silastic IUD fragments (15% and 30% for treated and contralateral horn, respectively) and a 0% pregnancy rate for Cu-IUD-treated animals (in either horn).

Animals↗

The multiload IUD--a U.S. researcher's evaluation of a European device.

This evaluative review focused on the performance and safety of the Dutch-made Multiload copper IUD, primarily the Multiload-375 (MLCu-375) model which has a longer life expectancy (5 or more years) than the Multiload-250 (MLCu-250) model, usually cited for a life expectancy for three years. This copper-medicated IUD differs from the copper-T IUDs in shape and insertion technique. The review shows that (a) the MLCu-375 IUD seems to be slightly less effective in preventing pregnancies than TCu-380A IUD. Its efficacy is comparable to that of the Nova-T by two to three years of use; (b) the MLCu-250 IUD is similarly effective to TCu-200 but may be slightly less effective than TCu-220C; (c) no consistent differences were detectable in expulsion rates or in removal rates for bleeding/pain between the Multiload IUDs and comparative Copper-T IUDs; (d) the Multiload IUDs may perform better in nulliparous women than the T-shaped devices; (e) no or a very low incidence of uterine perforation is associated with insertions of the Multiload IUD; (f) ectopic pregnancy risks are similarly low in Multiload IUD users as in Copper-T-380A users; and (g) pelvic inflammatory disease (PID) risks are similarly low in Multiload IUD users as in users of T-shaped copper IUDs.

Evaluation Studies as Topic↗

Contraceptive efficacy of the Copper T380A and the Multiload Cu250 IUD in three developing countries.

The clinical performance of the Copper T380A (TCu380A) and the Multiload 250 (MLCu250) intrauterine devices (IUDs) were evaluated for 12 months in a group of women who had one of the two IUDs inserted. Results are from a randomized clinical trial conducted at four collaborating research sites located in three developing countries. The gross cumulative life-table pregnancy rate of the TCu380A IUD was significantly lower than the rate with the MLCu250 IUD at 12 months (0.5 and 1.2, respectively, p < 0.01). No statistically significant differences between the two study IUDs were found with regard to IUD expulsion or IUD removal due to bleeding/pain, personal reasons, medical reasons, or planned pregnancy. TCu380A IUD users were more likely to report experiencing increased dysmenorrhea (p < 0.01) or intermenstrual pelvic pain (p < 0.01) than were MLCu250 IUD users. However, few of these users discontinued use of their assigned IUD because of having experienced menstrual bleeding disturbances or intermenstrual pelvic pain. These data indicate that the TCu380A IUD may be a better option than the MLCu250 IUD for women wishing to practice highly effective long-term birth control without having to resort to hormonal methods.

Adult↗

Lost levonorgestrel IUD: diagnosis and therapy.

A lost intrauterine device (IUD) is an uncommon event. Recently, a new levonorgestrel-releasing intrauterine system was introduced. In view of several cases of an unusual diagnostic discrepancy in the location of a lost levonorgestrel-releasing IUD in our department, we sought to determine if the extrauterine location of lost levonorgestrel-releasing IUDs differs from that of lost copper IUDs. The medical files of all patients with a diagnosis of lost IUD who were admitted to Rabin Medical Center from 2000 to 2003 were reviewed. Fourteen women were identified, 9 with levonorgestrel-releasing IUDs and 5 with copper IUDs. In six of the nine cases of a lost levonorgestrel-releasing IUD, there was a clear discrepancy between the presumed location of the device by diagnostic evaluation and its actual location on surgical extraction. All six devices were embedded in the omentum; four were located in the upper abdomen. No such discrepancies were noted for the copper IUDs (0 vs. 66%, p < 0.05). No significant difference in peritoneal adhesions was noted between the groups (55% vs. 66%, respectively, p = 0.095). It is concluded that lost levonorgestrel-releasing IUDs are associated with a higher rate of localization errors by clinical evaluation than copper IUDs. Lost levonorgestrel-releasing IUDs might be found in the mid-upper abdomen, embedded in omentum tissue, and this area should be explored first during laparoscopy.

Adult↗

The duration of use, causes of discontinuation, and problems during removal in women admitted for removal of IUD.

OBJECTIVE: Our aim was to determine the duration of intrauterine device (IUD) use, reasons for discontinuation, and problems encountered during removal in patients who were admitted to our clinic for removal of IUD. MATERIALS AND METHODS: We studied 321 cases of IUD removal with respect to duration of use, cause of removal, type of IUD used, and sociodemographic characteristics. The relationships among duration of use, patient's level of education, medical facility where the IUD was inserted, and number of children were analyzed. The reasons for removal and their relationship to duration of use were investigated. We also investigated the problems encountered during removal. FINDINGS: The mean age of cases included in the study was 34.8+/-1 years, mean number of children was 2.3+/-1.5, and mean duration of use was 5.8+/-3.9 years. The type of IUD most frequently removed was TCu-380A (86.3%). Although there was no correlation between the duration of use and the type of medical facility where the IUD was inserted, we observed that women with more children used IUDs for longer periods. When cases were evaluated for level of education, there was a statistically significant difference between university graduates and illiterate/primary school graduate women (p = .032 and .029, respectively). The reasons for removal were frequently side effects related to IUD use, expired date of use, and desire for conception. Pregnancy during IUD use was observed in 16 cases (5%). Removal of IUD was achieved without problems in 263 cases (81.9%), whereas alligator forceps needed to be used in 44 cases (13.7%). CONCLUSION: IUD is the most frequently used contraceptive method in our country. We have observed a long duration of use in the women studied, with minimal problems during removal.

Adult↗

T-shaped IUDs accommodate in their position during the first 3 months after insertion.

The objective of this study was to observe the position dynamics of the T-shaped intrauterine device (IUD) in the uterine cavity, from insertion to 90 days of use. IUD position was evaluated in 214 women by vaginal ultrasound, measuring the IUD-endometrium, IUD-myometrium, and IUD-fundus distances. The 90th percentile of the IUD-endometrium distance was 5, 6, and 8 mm at time of insertion, 30 and 90 days of use; 7, 9, and 10 mm for IUD-myometrium distance; and 23, 24, and 27 mm for IUD-fundus distance, respectively. Seventeen IUDs were classified as misplaced at insertion by using the 90th percentile of the IUD-myometrium distance as standard. Of these, only 6 remained misplaced after 90 days of use. On the other hand, 21 IUDs were beyond the 90th percentile at the 90-day observation, only 6 of which were considered misplaced at insertion. We conclude that the T-shaped IUD accommodates its position in the uterine cavity during the first 3 months following insertion, and that ultrasound evaluation of its position is not a good predictor of future evaluation.

Adult↗

IUDs are contraceptives, not abortifacients: a comment on research and belief.

No studies show that IUDs destroy developing embryos at rates higher than those found in women who are not using contraceptives. Studies of early pregnancy factors have not shown statistically significant differences in transient levels of hCG between IUD and control groups, a sign of early abortion. The small, careful study by Segal et al. (1985) found no transient rise of hCG in the IUD group. The highly sensitive assay in a larger sample of IUD users, by Wilcox et al. (1985), suggests that an upper limit of only 3 or 4 percent of ovulatory matings with an IUD in situ might show transient rises of hCG. The electron microscopy of Hurst et al. (1980) demonstrated the existence of leukocyte-ridden degenerating embryos in rhesus monkeys fitted with IUDs, but found the same percentage of degenerating embryos in the control group. In this respect, IUDs do no more than nature. The work of Hurst et al. also demonstrates the comparative rarity of fertilized ova in rhesus monkeys fitted with IUDs. Croxatto (1974) and Alvarez et al. (1988) showed that this was also true for humans. A variety of studies demonstrate that IUD use diminishes both the number of sperm reaching the oviduct and their capacity to fertilize ova. Depending on the type of IUD and the drug dose, sperm are hindered from penetrating cervical mucus, are phagocytized by leukocytes, are incapacitated, with head-tail separation in the presence of copper, and suffer other cytotoxic effects in the IUD-altered uterine fluid. In the oviducts of copper-IUD users, ova are found significantly less frequently than in controls.(ABSTRACT TRUNCATED AT 250 WORDS)

Abortifacient Agents↗

Malonaldehyde production around copper IUDs.

Specimens of cervical mucus from 7 women fitted with copper IUDs were placed immediately after collection in liquid nitrogen. These specimens were shown by electron paramagnetic resonance measurements to contain statistically significantly higher concentrations of free radicals than similar specimens from 6 women fitted with plastic Lippes loops. Cervical mucus, collected from women immediately prior to elective removal of an IUD, was placed in 2M hydrochloricacid and later analyzed for malonaldehyde using a newly developed polarographic method. Positive results were obtained for 8 of 19 women fitted with copper IUDs, but for none of 21 women fitted with plastic devices. Cervical mucus was similarly collected from 10 women fitted with copper IUDs, 9 women fitted with plastic IUDs, and an additional 9 using other methods of contraception. Mucus was collected 3 times (early, middle, and late cycle). No malonaldehyde was detected in mucus from women with plastic IUDs, or other contraceptive methods. Positive results were obtained in 13 of 29 mucus specimens from those using copper IUDs. Stage of menstrual cycle did not influence the percentage of positive results. Malonaldehyde was detected in vitro in solutions of arachidonate or prostaglandin F2alpha in buffered saline incubated with sterile copper IUD, but not with the plastic. Rate of malonaldehyde production was markedly influenced by pH, temperature, agitation, substrate concentration, and size of gas-liquid interface. the rates of malonaldehyde production around the copper IUD in utero are unknown. The possible increased risk of carcinogenicity associated with the copper IUD is discussed.

Biology↗

Quantitative studies on menstrual blood loss in IUD users.

Despite the introduction of new intrauterine devices (IUDs), the most important complication involving their use continues to be excessive menstrual bleeding. IUD use in developing countries with women who are already depleted in body iron stores may prove to be deleterious to their health. Mean amounts of menstrual blood loss (MBL) for women not using contraception in the western world is about 32 ml. This mean is increased to 52-72 ml with use of the Lippes loop and other non-medicated devices up to 24 months after insertion. For the Copper-7 and Copper-T-200 devices this mean increase is to 37-40 ml in the first month, decreasing to 30-38 ml at 12 months after IUD insertion. In the users of the Multiload-250 IUD at one month post-insertion the MBL is from 56 to 63 ml and from 36 to 39 ml at 24 months of use. The mean Multiload-375 device users at one month after insertion lose a mean of 45-73 ml at 24 months, 35-50 ml. With the progestogen-releasing IUD mean MBL is 27-36 ml at 1 month and 9-13 ml at 12 months post-insertion. Intermenstrual blood loss is significant only in the first month of use for all IUDs. Discontinuation rates for pain and bleeding with non-medicated IUDs are from 11.0-19.6 per 100 women per year, and for the copper IUDs 4.4 to 6.8 per 100 women in the first year of use. The main problem with prolonged menstrual bleeding is depletion of the body iron stores; this is highly significant with non-medicated devices, less important with copper devices and conversely, iron stores are increased in users of progestogen-releasing devices. This is based on serum ferritin measured up to 24 months after insertion. The ferritin values correlated well with the volumes of MBL. It is suggested, especially for women with low body iron stores, that there is an order of preference for IUDs to be used. This should be: firstly, the progestogen-releasing devices; secondly, the Copper-T and Copper-7 IUDs; thirdly the larger surface copper devices (Cu-T-220C, Multiload 250 and 375, Cu-T-380). Non-medicated devices are not to be recommended for these women.

Anemia, Hypochromic↗

Uterine cavity and the location of IUDs following administration of meclofenamic acid to menorrhagic women. A pilot study.

The relationship between the uterus and the IUD was studied selectively with hysterosalpingograms in 18 menorrhagic women previously treated with Meclofenamic acid (M Ac.), a well known anti-inflammatory drug. Major anomalies (embedding, perforation, rotation) were found in 28.6% of those patients who responded positively to M Ac. In contrast, major anomalies were found in 63.6% of those patients who responded negatively to the drug. It is proposed that the negative response to M Ac. might be due to severe macroscopic disturbances of the uterine wall-IUD relationship. The degree of response to M Ac. might contribute to the decision to remove the IUD from menorrhagic women. In addition, 84.7% anomalies (deformities, embedding, perforation) in the uterine-IUD relationship were found in 13 women with a T-shape IUD device. The fact that those anomalies are related to the tip of the horizontal arm justifies future studies using shortened arms to diminish hypermenorrhea induced by T-shape devices or attempts to use IUDs which do not have the conventional plastic frame, as in the Cu-Fix IUD which has been mentioned as particularly useful to prevent bleeding side effects and pain induced by conventional IUDs. The Cu-Fix IUD consists of 6 sleeves made of pure (99.99%) copper, each sleeve with a length of 5 mm and an outer diameter of approximately 2.2 mm, threaded on surgical 00 monofilament polypropylene (ProleneR, Ethicon). The total area of exposed copper is approximately 390 mm2. The sleeves are prevented from sliding off the suture by 2 smaller copper tubules crushed on the thread in both ends of the IUD structure. This thread-type, copper-bearing device has been designed to overcome the most common IUD-related problems, bleeding and pain.

Adolescent↗

[Insertion of intrauterine device in general practice. Which women choose the IUD, and how is the procedure done?].

INTRODUCTION: In Denmark most IUDs are inserted by general practitioners (GPs). The aim of this study was to throw light on which women choose IUD, the procedure used, and difficulties associated with insertion. MATERIAL AND METHODS: All 232 GPs in Frederiksborg County were invited to participate and 88 agreed. The GP filled in a questionnaire concerning the type of IUD, the age, parity, etc, of the woman and information about the insertion. RESULTS: Eighty-eight GPs contributed with 562 IUD insertions. IUD was mostly used by women above 25 years of age and by women who had given birth to a child. There were no differences in the insertion procedures used by the doctors. Fifty-nine per cent of the women were previous IUD users. Of the former users, 37% reported problems with the previous use of the IUD. Twenty-five per cent of the women in this study reported that they had had heavy or long-lasting menstruation before insertion. Fifty-five per cent of the women had a test for chlamydia before insertion. Twenty-three (4.1%) insertions were abandoned. 26 (4.6%) insertions were described as difficult. The highest frequency was in women using gestagen-releasing IUDs. CONCLUSION: IUD was mainly used by women, who had given birth to a child. The gestagen releasing IUD was mostly used by the elder group and by women with heavy bleedings before insertion. The procedure was very identical and the number of abandoned and difficult insertions were low and only related to the type of IUD. More female than male doctors participated. Doctors working in partnerships participated more frequently than doctors working alone.

Adult↗

Ectopic IUD complicating pregnancy. A case report.

BACKGROUND: For the most part, intrauterine devices (IUDs) have a low complication rate and minimal side effects. However, one of the most common reasons for contraceptive failure while using an IUD is its translocation or extrauterine migration. Pregnancy complicated by translocation or an ectopic IUD can present a formidable clinical challenge. CASE: A 23-year-old woman, gravida 3, para 2, using a copper-7 IUD for contraception, presented at 7 weeks' gestation. Transvaginal sonogram confirmed the presence of a fetal pole with cardiac activity; however, the IUD was not detectable. An anteroposterior roentgenogram showed 90 degrees counterclockwise rotation of the IUD relative to the normal position. Laparoscopy was performed at 14 weeks. The IUD was extrauterine, buried in omental adhesions attached to the anterior abdominal wall. The IUD was dissected free and removed without difficulty. The remainder of the pregnancy was uncomplicated. CONCLUSION: Uterine perforation is a recognized and potentially hazardous complication of IUD use. Localization of a lost IUD should follow an organized and systematic approach utilizing an assortment of radiologic and operative techniques. We report the third known case utilizing laparoscopy to remove an ectopic IUD complicating early pregnancy. Laparoscopy, even during pregnancy, has proven to be a safe and simple tool for managing a variety of surgical conditions.

Adult↗

Five years' experience with levonorgestrel-releasing IUDs.

Two levonorgestrel-releasing IUDs and a copper-releasing IUD of the same shape were studied in a randomized comparative study over five years. The levonorgestrel-releasing IUDs released 20 micrograms or 30 micrograms per day. The Pearl index during the 10,600 woman-months of LNG-IUD use was 0.11. The control device releasing copper had a Pearl index of 1.6. The amount and duration of menstrual bleeding was greatly reduced, leading to a high incidence of oligo- or amenorrhea. The continuation rate in this pioneer trial was 53 per 100 users for the levonorgestrel-releasing IUD (LNG-IUDs) and 50 per 100 users for the copper-releasing IUD (Nova T). The removal rates for reasons other than amenorrhea were not significantly different. Discontinuation because of amenorrhea occurred during the first two years, the cumulative termination rate for this reason was 11.6 per 100 users at five years. The LNG-IUDs removed for investigation after five years of use revealed that the devices contained about 40 percent of the original load. The effective lifespan of the device has been demonstrated by this study to be five years; the residual steroid gives an additional safety period of two more years. The LNG-IUD is a highly effective reversible contraceptive method, which strongly reduced the amount and duration of bleeding. During the first two months there is scanty but frequent spotting which, like the high incidence of oligo- and/or amenorrhea, requires counselling of health personnel and women using LNG-IUDs.

Adult↗

Clinical performance of the TCu 380A and TCu 220C IUDs in four developing country family planning clinics.

The clinical performance of the Copper T 380A (TCu 380A) and the Copper T 220C (TCu 220C) intrauterine devices (IUDs) were evaluated for 12 months in a group of women who had one of the two IUDs inserted. Results are from a randomized clinical trial conducted at four collaborating research sites located in two developing countries. The gross cumulative life-table pregnancy rate of the TCu 380A IUD was found to be lower than that of the TCu 220C IUD at 12 months (0.3 and 0.8, respectively), although this difference was not statistically significant (p > 0.05). Statistically significant differences between the two study IUDs were not found with regard to IUD expulsion or IUD removal due to bleeding/pain, personal reasons, medical reasons, or planned pregnancy. No statistically significant differences were observed in the frequency of experiencing menstrual disturbances (i.e., dysmenorrhea, intermenstrual pelvic pain or intermenstrual bleeding) between the two IUD groups. These data suggest that the TCu 380A and TCu 220C IUDs are both appropriate options for contracepting women. The TCu 380A IUD, however, may be a more appropriate option for those women wishing to space births over a longer period of time.

Adolescent↗

Performance of the frameless GyneFix and the TCu380A IUDs in a 3-year multicenter, randomized, comparative trial in parous women.

This study was conducted to evaluate a new and improved inserter (GyneFix) for the anchoring of the Frameless IUD in the uterine cavity. Previous studies conducted with a prototype inserter (Flexigard) did not show fully the advantages of the new anchoring concept because of the shortcomings of the Flexigard inserter and the complexity of the insertion technique. The GyneFix IUD was compared with the TCu380A IUD in six centers in China in approximately 300 women in each group. Only parous women were included in the study. The data from this 3-year, ongoing study demonstrate that the shortcomings of the inserter have been corrected, resulting in better performance and a much reduced rate of failed insertion/expulsion of the frameless and anchored device. The cumulative expulsion rate with the GyneFix IUD was 3.0 at 3 years (annual rates 2.67, 0.33, and 0.0, respectively) compared with a cumulative expulsion rate of 7.38 at 3 years with TCu380A (annual rates 4.63, 1.76, and 1.04, respectively). This difference is statistically significant. The majority of the expulsions with the anchored IUD occurred early in the study, indicating improper anchoring technique. The study also shows that both devices are highly efficacious. No pregnancies occurred with the GyneFix IUD (cumulative pregnancy rate 0.0 at 3 years) versus one pregnancy with TCu380A (cumulative pregnancy rate 0.34 at 3 years). The total use-related discontinuation rate at 3 years was significantly lower with the GyneFix IUD (8.34) than with the TCu380A IUD (14.13) and results in a higher rate of continuation with the GyneFix IUD compared to the TCu380A IUD (90.73 vs 85.25). Neither perforations nor pelvic inflammatory disease cases were encountered with either device in this study, demonstrating the safety of the anchoring system.

Adolescent↗

The comparative trial of TCu 380A IUD and progesterone-releasing vaginal ring used by lactating women.

The objective of this paper was to compare the efficacy, acceptability, safety, and bleeding pattern of TCu 380A intrauterine device (IUD) and progesterone-releasing vaginal ring used by breastfeeding women. The study population included 97 breastfeeding women using IUD and 100 women using vaginal ring. Of the IUD users, no insertion failure, perforation, or accidental pregnancy occurred in 12 months. There was one IUD expulsion. There were no discontinuations of IUD due to medical reasons other than expulsion. The total discontinuation rate was 2.3%. In the ring group, no accidental pregnancy occurred. The major reasons for discontinuation were ring use-related problems and vaginal problems. The total discontinuation rate was 65.4% within 1 year. The frequency of any one complaint among the ring users was higher than that among the IUD users. There were no differences in the proportion of women having no sexual activity and in the weight of their babies between the two groups. Compared with the IUD users, the median number of bleeding/spotting (B/S) episodes and B/S days of the vaginal ring users were fewer; consequently, the mean length of B/S-free interval was longer in all four reference periods; the mean length of B/S episode and segment were the same; the occurrence of amenorrhea was more frequent; in contrast, the proportions of normal bleeding patterns were fewer. The frequencies of prolonged bleeding, frequent bleeding, and infrequent bleeding patterns did not differ between the two groups. The percentage of irregular bleeding was fewer only in the first two reference periods. It is concluded that the TCu 380A IUD and progesterone-releasing vaginal ring used by breastfeeding women are safe and effective. The higher discontinuation rate of the ring users was mainly because of use-related problems. Breastfeeding women with TCu 380A IUD had better tolerance and acceptability. The TCu 380A IUD does not, but the progesterone-releasing vaginal ring does, suppress the recovery of ovarian function. However, once return of menstruation occurred, there were no differences in bleeding patterns between the two contraceptive methods.

Administration, Intravaginal↗

Performance of the frameless IUD (Flexigard prototype inserter) and the TCu380A after six years as part of a WHO multicenter randomized comparative clinical trial in parous women.

The clinical performance of the new Frameless IUD was compared with the TCu380A, the most widely used copper IUD in the world today. Insertions of the Frameless IUD were conducted with a prototype inserter (Flexigard). We report on the 6-year results from a randomized comparative clinical trial conducted at the Shanghai Institute of Planned Parenthood Research, as part of an international multicenter WHO clinical trial, involving 200 women, respectively recruited for use of each device. The cumulative 6-year pregnancy rates were 0.0 per 100 women for the Frameless IUD and 3.3 for TCu380A. Termination due to partial expulsion was significantly less for the Frameless IUD as compared with TCu380A (0.0 and 4.3 per hundred women, respectively). Complete expulsion, bleeding, pain, bleeding and pain and other medical reasons for termination did not differ significantly between the two devices. The net cumulative continuation rates at six years per 100 women were 80.8 for TCu380A, and 83.0 for the Frameless IUD. Both Frameless IUD and TCu380A are highly effective, safe and acceptable contraceptive devices, because of low pregnancy rates (per 100 women), and low termination rates due to expulsion, pain, bleeding, and bleeding and pain. Due to its anchoring, the Frameless IUD is significantly more effective than the TCu380A IUD as regards proper retention of the IUD in the uterine cavity. This may also explain its lower failure rate.

Adult↗

Interception by post-coital IUD insertion.

After the development of postcoital hormonal interception, the postcoital use of IUDs to prevent pregnancy was proposed by Tatum. The major advantage of this treatment is that it avoids the use of the usual massive dose of estrogens (a very effective postcoital method) which is associated with nausea and vomiting. This is the 1st method to be effective up to 5 days after exposure, 3 days more than the estrogen treatment. It may also provide long-term contraception in women who wish to continue using the IUD. A major disadvantage of postcoital IUD use is that IUD insertion can produce serious complications if a patient has a vaginal or venereal infection or an asymptomatic cervicitis or even pelvic inflammatory disease (PID). After proper physical examination, suitable patients are selected from those requesting postcoital treatment. Cases involving rape are mostly excluded from these services; but, if they present early, proper work up and treatment can be performed within the time span of 5 days available for this method and it will still be possible to fit a postcoital IUD. The potential risk of future infertility should be considered as PID rates in nulliparous IUD users are up to 7 times higher than in nonusers. Young nulliparous, sexually active women--especially of the lower socioeconomic strata--are identified as high-risk patients. Over 70% of women requesting interception are nulliparous. Clients asking for postcoital insertion should be informed of its potential risk, as women under 25 years of age are more prone to infection. The risk of septic abortion exists if an IUD is inserted into a gravid uterus due to pregnancy resulting from unreported previous sexual intercourse. Septic abortion is a life-threatening condition. Out of several series, no pregnancies are reported in the month of treatment. The IUD preferred is the Multiload copper IUD or the copper T; the highest expulsion rate proved the Copper-7 Gravigard (Cu-7) inefficient. In suitable circumstances, the IUD can be the 1st choice in postcoital interception.

Age Factors↗