Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “GASES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

The opposing physiological effects of high pressures and inert gases.

The physiological effects on mammals of elevated pressures (approximately 100 atmospheres) must be considered in the context of the inert gases breathed. The most striking effect of pressure per se is a central hyperexcitability manifest at first by trembling of the entremities and finally by convulsions. Paralysis and death occur at higher pressures. The primary effects of the inert gases breathed are inert gas narcosis and general anesthesia. The exciting effects of pressure per se and the depressive effects of the inert gases tend to oppose each other. Thus consciousness may be restored to anesthetized mice by raising the pressure, and conversely the threshold pressure that causes convulsions is elevated in the presence of anesthetics. These mutually antagonistic effects can be rationalized in terms of model which proposes that both anesthetics and pressure non-specifically perturb thelipid bilayer regions of neutral membranes. This model is termed the critical volume hypothesis. Anthesthetics dissolve in and expand these lipid bilayer regions, while pressure causes mechanical compression. Expansion leads to anesthesia and compression to convulsions if a critical degree of change is achieved. At elevated partial pressures of inert gas the gas-induced expansion is opposed by the compression of pressure per se. With very insoluble gases, such as helium, this expansion is so small that net compression results and the effects of helium differ little from those of pressure per se. With more soluble gases, such as nitrogen, net expansion results in inert gas narcosis and anesthesia. The critical volume hypothesis enables "safe" mixtures of "expanding" and "compressing" gases to be defined. These enable higher pressures to be better tolerated by mammals.

Anesthesia↗

[Climatization of anesthetic gases using different breathing hose systems].

BACKGROUND: During general anaesthesia gas climate significantly is improved by performance of low flow techniques. Gas climatisation, however, markedly also will be influenced by the temperature loss at, and corresponding water condensation within the hoses, factors which are related to the technical design and material of the patient hose system. The objective of this prospective study was to investigate 1. how anaesthetic gas climatisation during minimal flow anaesthesia is influenced by the technical design of different breathing hose systems in clinical practice. 2. to investigate, whether a sufficient gas climatisation also can be gained with higher fresh gas flows if that hose system is used, proven beforehand to optimally warming and humidifying the anaesthetic gases. METHODS: Three different systems, a conventional two-limb hosing consisting of smooth silicone hoses, a coaxial hosing, and a hosing consisting of actively heated breathing hoses, attached to a Dräger Cicero EM anaesthesia machine, were used during minimal flow anaesthesia with a fresh gas flow of 0.5 l/min. Gas temperature and absolute humidity were measured at the tapered connection between the inspiratory limb and the breathing system as well as at its connection to the endotracheal tube. The best gas climatisation was observed if heated breathing hoses were used. Thus, using this hosing, additionally gas temperature and humidity in the inspiratory limb were taken at fresh gas flow rates of 1.0, 2.0 and 4.4 l/min respectively. Measurements were performed in all groups at all general anaesthesias lasting at least 45 minutes during the lists of eight different days each. RESULTS: In minimal flow anaesthesia, with all hose systems likewise, generally an absolute humidity between 17 to 30 mgH2O/l is reached at the endotracheal tube's connector during the course of the list. Only in the first cases of the day there was a short delay of 15 to 30 minutes before reaching a humidity of at least 17 mgH2O/l. Only with heated hoses, however, humidity frequently even exceeded 30 mgH2O/l. If conventional or coaxial hosings were used, during minimal flow anaesthesia gas temperatures in an acceptable range between 23 to 30 degrees C were measured at the tube connector. With heated hoses, however, warming of the gases was excellent with gas temperatures between 28 to 32 degrees C. In minimal flow anaesthesia climatisation of the anaesthetic gases proved to be best if heated hoses were used. Thus, using heated hose systems another three trials with increasing fresh gas flow rates of 1.0, 2.0 and 4.4 l/min respectively were performed. Whereas climatisation of the anaesthetic gases still was found to be optimal with a fresh gas flow of 1.0 l/min, the humidity dropped drastically to values lower than 17 mgH2O/l at 2.0 l/min and even down to 10 mgH2O/l at a flow rate of 4.4 l/min. Gas temperatures, however, turned out to be independent of the flow and remained at 28-32 degrees C, even at a flow as high as 4.4 l/min. CONCLUSIONS: Using conventional hose systems and coaxial hosings acceptable, but not optimal climatisation of the anaesthetic gases can be gained if minimal flow anaesthesia is performed. The use of a coaxial hose system seems to lead to improved climatisation in long lasting procedures only. In routine clinical practice, however, conventional and coaxial hose systems are similar in respect to the climatisation of breathing gases. Heated breathing hoses performed markedly better in terms of climatisation of the breathing gas than the coaxial and the conventional hose system. With this hosing not only sufficient but optimal moisture and temperature values are realized. Optimal climatisation, however, only can be gained if low flow anesthetic techniques with fresh gas flows equal or less than 1 l/min are performed. With higher fresh gas flow rates the humidity decreases markedly while high gas temperatures are maintained. (ABSTRACT TRUNCATED)

Aged↗

Tumour radiosensitization by high-oxygen-content gases: influence of the carbon dioxide content of the inspired gas on PO2, microcirculatory function and radiosensitivity.

PURPOSE: To measure the effects of breathing high-oxygen-content gases, with a CO2 fraction of between 0 and 10%, on tumour radiosensitivity, blood flow and oxygenation. METHODS AND MATERIALS: The murine sarcoma F was used, implanted subcutaneously (s.c.) in syngeneic CBA mice. We assessed the induced changes in tumour microregional blood flow and oxygenation using laser Doppler flowmetry, and pO2 histography, respectively. Radiation response was determined using an in vivo-in vitro clonogenic assay 18-20 h post treatment. RESULTS: The results show that the level of radiosensitization achieved is dependent on both the CO2 content of the inspired gas and the duration of gas breathing. No radiosensitization was evident following inhalation of 90% O2 + 10% CO2. All other gases elicited radiosensitization; however, that achieved with 100% O2 disappeared at the extended preirradiation breathing time of 45 min. At this time, radiosensitization was maintained for gases containing 1%, 2.5%, or 5% CO2. Changes in oxygenation, as measured by PO2 electrodes, did indicate improved oxygenation status during inhalation of the gases. However, the time-course and extent of the changes did not mirror accurately the changes in radiosensitization. All the gases with a CO2 content of 2.5% or greater induced a 10-20% reduction in microregional blood flow, with no change evident following inhalation of 100% O2 or 99% O2 + 1% CO2. CONCLUSIONS: The data imply that the decreased radiosensitization seen at extended breathing times of oxygen is unrelated to blood flow changes. The fact that radiosensitization is seen with extended breathing times of gases containing 2.5% and 5% CO2, despite blood flow decreases, is indicative of other overriding physiological changes, perhaps related to oxygen utilisation. The studies overall indicate that, at least in the tumour investigated, radiosensitization is not affected if the CO2 content of the inspired gas is reduced from 5% to 2.5%, or even 1%. Further evaluation of the radiosensitizing effects of such gas mixtures is now warranted. In addition, comparison with recent studies of other tumour types, where carbogen has been shown to improve tumour blood flow, suggests that this may be a tumour-specific phenomenon. Based on these data, further effort is required to elucidate the physiological mechanisms that determine these blood flow changes.

Administration, Inhalation↗

A thermodynamic assessment of the potential synthesis of condensed hydrocarbons during cooling and dilution of volcanic gases.

The possibility for abiotic synthesis of condensed hydrocarbons in cooling/diluting terrestrial volcanic gases has been evaluated on the basis of the consideration of metastable chemical equilibria involving gaseous CO, CO2, H2 and H2O. The stabilities of n-alkanes and polycyclic aromatic hydrocarbons (PAHS) have been evaluated for several typical volcanic gas compositions under various conditions for cooling/diluting of quenched volcanic gas. The modeling shows that n-alkanes and PAHs have a thermodynamic potential to form metastably from H2 and CO below approximately 250 degrees C within the stability field of graphite. Despite the predominance of CO2 in volcanic gases, synthesis of hydrocarbons from CO2 and H2 is less favored energetically than from CO and H2. Both low temperature and a high H/C atomic ratio in volcanic gas generally favor stability of hydrocarbons with higher H/C ratios. PAHs are thermodynamically stable at temperatures approximately 10 degrees -50 degrees C higher than large n-alkanes; however, at lower temperatures, PAHs and n-alkanes have similar stabilities and are likely to form metastable mixtures. Both the energetic drive to form hydrocarbons and possible temperatures of formation increase as the oxidation state (fO2) of the volcanic gases decreases and as the cooling/dilution ratios of volcanic gases increase. Synthesis of hydrocarbons is energetically more likely in cooling trapped gases than in ashcloud eruptive columns. Mechanisms for hydrocarbon formation may include Fischer-Tropsch-type synthesis catalyzed by magnetite from solid volcanic products. On the early Earth, Mars, and Jupiter's satellite Europa, several factors would have provided more favorable conditions for hydrocarbon synthesis in volcanic gases than under current terrestrial conditions and might have contributed to the production of organic compounds required for the emergence of life.

Alkanes↗

An alternative approach to establishing trade-offs among greenhouse gases.

The Kyoto Protocol permits countries to meet part of their emission reduction obligations by cutting back on gases other than CO2 (ref. 1). This approach requires a definition of trade-offs among the radiatively active gases. The Intergovernmental Panel on Climate Change has suggested global warming potentials for this purpose, which use the accumulated radiative forcing of each gas by a set time horizon to establish emission equivalence. But it has been suggested that this approach has serious shortcomings: damages or abatement costs are not considered and the choice of time horizon for calculating cumulative radiative force is critical, but arbitrary. Here we describe an alternative framework for determining emission equivalence between radiatively active gases that addresses these weaknesses. We focus on limiting temperature change and rate of temperature change, but our framework is also applicable to other objectives. For a proposed ceiling, we calculate how much one should be willing to pay for emitting an additional unit of each gas. The relative prices then determine the trade-off between gases at each point in time, taking into account economical as well as physical considerations. Our analysis shows that the relative prices are sensitive to the lifetime of the gases, the choice of target and the proximity of the target, making short-lived gases more expensive to emit as we approach the prescribed ceiling.

Journal Article↗

A biological model of tamponade gases following pneumatic retinopexy.

PURPOSE: Predict the persistence and expansion of intra-ocular tamponade gases used in retinal detachment surgery. Quantify factors that contribute to elevations in the intraocular pressure. METHODS: We developed a non-equilibrium physiological model of intraocular gas transfer in vitreoretinal surgery. The model was calibrated using published volumetric decay measurements for four perfluorocarbon gases (CF(4), C(2)F(6), C(3)F(8), C( 4)F(10)) injected into the New Zealand red rabbit. We validated the model by comparing predicted and experimental results at different conditions in the rabbit. Using the rabbit results, the model was scaled up to humans. RESULTS: Predictions of gas expansion, half-life, and intraocular pressure in humans were found to correlate very well with clinical results. Gas transfer in the eye was controlled by diffusion through plasma and membranes. Although intraocular pressure depended on several complicating factors such as the physiological condition of the eye as well as the medications being used, prediction of conditions that favor elevations in intraocular pressure were identified based on the transport and thermodynamic properties of the gases. CONCLUSIONS: The biological model accurately predicted the dynamics of intraocular gases in the human eye. The major factor affecting the intraocular pressure was the aqueous humor dynamics, which is highly dependent on the physiological conditions in the eye. However, for long duration gases such as perfluoropropane, elevations in intraocular pressure are possible following an increase in volume and/or purity of the injected gas. By injecting a mixture of air with an expansive gas, it is possible to reduce elevations in intraocular pressure in patients with the trade off of a reduced longevity of the gas bubble. For gases that diffuse faster than perfluoropropane, there are minimal effects on intraocular pressure due to these changes.

Animals↗

Microbial growth modification by compressed gases and hydrostatic pressure.

Studies of the growth-modifying actions for Escherichia coli, Saccharomyces cerevisiae, and Tetrahymena thermophila of helium, nitrogen, argon, krypton, xenon, and nitrous oxide led to the conclusion that there are two definable classes of gases. Class 1 gases, including He, N(2), and Ar, are not growth inhibitors; in fact, they can reverse the growth inhibitory action of hydrostatic pressures. Class 2 gases, including Kr, Xe, and N(2)O, are potent growth inhibitors at low pressures. For example, at 24 degrees C, 50% growth-inhibitory pressures of N(2)O were found to be ca. 1.7 MPa for E. coli, 1.0 MPa for S. cerevisiae, and 0.5 MPa for T. thermophila. Class 1 gases could act as potentiators for growth inhibition by N(2)O, O(2), Kr, or Xe. Hydrostatic pressure alone is known to reverse N(2)O inhibition of growth, but we found that it did not greatly alter oxygen toxicity. Therefore, potentiation by class 1 gases appeared to be a gas effect rather than a pressure effect. The temperature profile for growth inhibition of S. cerevisiae by N(2)O revealed an optimal temperature for cell resistance of ca. 24 degrees C, with lower resistance at higher and lower temperatures. Overall, it appeared that microbial growth modification by hyperbaric gases could not be related to their narcotic actions but reflected definably different physiological actions.

Journal Article↗

Safe use of medical gases in the clinical setting: practical tips.

For a variety of reasons, nurses, midwives and health visitors may have to be involved in administration of many types of medical gases. In order to provide safe and effective care the nurse must be aware of the implications of his/her practice. This article discusses and describes the many types of medical gases available in clinical practice. The article focuses on four commonly used gases: oxygen, air, nitrous oxide and entonox. Practical tips are offered and the focus is made on the safe and effective use of the gases. Details regarding the storage and administration of medical gases are outlined. Finally, some of the potential dangers associated with the gases are discussed.

Anesthetics, Inhalation↗

Controlling diffusion of 3He by buffer gases: a structural contrast agent in lung MRI.

PURPOSE: To study the influence of admixing inert buffer gases to laser-polarized (3)He in terms of resulting diffusion coefficients and the consequences for image contrast and resolution. MATERIALS AND METHODS: The diffusion coefficient of (3)He was altered by admixing buffer gases of various molecular weights ((4)He, N(2), and SF(6)). The influence of the pulse sequence and the diffusion coefficient on the appearance of MRI of (laser-polarized) gases was analyzed by comparison of basic theoretical concepts with demonstrative experiments. RESULTS: Excellent agreement between theoretical description and observed signal in simple gradient echoes was observed. A maximum signal gain can be predicted and was experimentally validated. Images acquired under such conditions revealed improved resolution. The nature and concentration of the admixed gas defines a structural threshold for the observed apparent diffusion coefficient (ADC) as demonstrated with diffusion-weighted MRI on a pig's lung flooded with suitable gas mixtures. CONCLUSION: A novel procedure is proposed to control the diffusion coefficient of gases in MRI by admixture of inert buffer gases. Their molecular mass and concentration enter as additional parameters into the equations that describe structural contrast. This allows for setting a structural threshold up to which structures contribute to the image. For MRI of the lung this enables images of very small structural elements (alveoli) only, or in the other extreme, all airways can be displayed with minimal signal loss due to diffusion.

Contrast Media↗

Technique for measurement of inert gases in liquids by gas chromatography.

A method for quantitative analysis of inert gases in liquids by gas chromatography is described. The technique comprises an equilibration system for partial extraction of dissolved gases from liquids and a gas chromatograph equipped with helium ionization detector. The method is particularly devised for determination of solubility coefficients of gases in liquid materials, e.g. water, aqueous solutions, blood, tissue homogenates, and for simultaneous measurement of several inert gases dissolved in liquids. Coefficients of variation for serial analyses of individual samples were less than or equal to 3%. The method is applicable to studies of blood-tissue transfer of respiratory and inert gases.

Chromatography, Gas↗

Dose concepts for inhaled vapors and gases.

"Dose" for any toxicant is a shifting concept; thus, there is a frequent need for modifiers such as "administered" or "effective," when referring to dose. When applied to inhaled gases and vapors, "dose" is even more vague. The wide range of physicochemical properties associated with gases and vapors, the different target tissues that may be affected, and the variety of mechanisms involved in producing toxic effects combine to make a useful dose descriptor for one gas inadequate for another. Although models have been developed to describe dose for inhaled gases and vapors having a broad range of properties, it is often not clear which models are appropriate for which inhalant. In an attempt to resolve this dilemma, a classification scheme for inhaled gases and vapors, based on physicochemical properties, is offered in this report. In addition, various concepts of dose for inhaled gases and vapors are discussed with reference to the classification scheme. Finally, avenues for further research in the area of gas and vapor dosimetry are suggested.

Administration, Inhalation↗

Effects of irritant gases on avoidance/escape performance and respiratory response of the baboon.

The major toxicants in smoke are generally categorized as asphyxiants (hypoxia-producing agents) and irritants. Although the rodent appears to be an adequate model for evaluating the toxic effects of asphyxiant gases in man, the suitability of the rodent for evaluating the effects of irritant gases has not been established. In a study of the effects of irritant gases on escape performance of the baboon, exceedingly high concentrations of neither acrolein nor hydrogen chloride (HCl) prevented performance of the behavioral task; however, severe irritant effects were evident, even at lower concentrations. In a subsequent study of the respiratory response of the baboon to HCl, 15-min exposures to 5000 and 10,000 ppm (nominal concentrations) produced severe hypoxemia with a concentration-related increase in respiratory rate and minute volume. The difference between the rodent and the nonhuman primate in response to irritant gases suggests that the rodent may be an inadequate model for evaluating the toxicity of irritant gases to man and, therefore, the use of results of laboratory combust combustion tests to predict the toxicity of smoke in humans may lead to erroneous conclusions.

Acrolein↗

Process engineering design of pathological waste incinerator with an integrated combustion gases treatment unit.

Management of medical wastes generated at different hospitals in Egypt is considered a highly serious problem. The sources and quantities of regulated medical wastes have been thoroughly surveyed and estimated (75t/day from governmental hospitals in Cairo). From the collected data it was concluded that the most appropriate incinerator capacity is 150kg/h. The objective of this work is to develop the process engineering design of an integrated unit, which is technically and economically capable for incinerating medical wastes and treatment of combustion gases. Such unit consists of (i) an incineration unit (INC-1) having an operating temperature of 1100 degrees C at 300% excess air, (ii) combustion-gases cooler (HE-1) generating 35m(3)/h hot water at 75 degrees C, (iii) dust filter (DF-1) capable of reducing particulates to 10-20mg/Nm(3), (iv) gas scrubbers (GS-1,2) for removing acidic gases, (v) a multi-tube fixed bed catalytic converter (CC-1) to maintain the level of dioxins and furans below 0.1ng/Nm(3), and (vi) an induced-draft suction fan system (SF-1) that can handle 6500Nm(3)/h at 250 degrees C. The residence time of combustion gases in the ignition, mixing and combustion chambers was found to be 2s, 0.25s and 0.75s, respectively. This will ensure both thorough homogenization of combustion gases and complete destruction of harmful constituents of the refuse. The adequate engineering design of individual process equipment results in competitive fixed and operating investments. The incineration unit has proved its high operating efficiency through the measurements of different pollutant-levels vented to the open atmosphere, which was found to be in conformity with the maximum allowable limits as specified in the law number 4/1994 issued by the Egyptian Environmental Affairs Agency (EEAA) and the European standards.

Air Pollution↗

The use of static pressures of heavy gases within a quadrupole ion trap.

The performance of quadrupole ion traps using argon or air as the buffer gas was evaluated and compared to the standard helium only operation. In all cases a pure buffer gas, not mixtures of gases, was investigated. Experiments were performed on a Bruker Esquire ion trap, a Finnigan LCQ, and a Finnigan ITMS for comparison. The heavier gases were found to have some advantages, particularly in the areas of sensitivity and collision-induced dissociation efficiency; however, there is a significant resolution loss due to dissociation and/or scattering of ions. Additionally, the heavier gases were found to affect ion activation and deactivation during MS/MS, influencing the product ion intensities observed. Finally, the specific quadrupole ion trap design and the ion ejection parameters were found to be crucial in the quality of the spectra obtained in the presence of heavy gases. Operation with static pressures of heavy gases can be beneficial under certain design and operating conditions of the quadrupole ion trap.

Argon↗

Pumping-induced ebullition: a unified and simplified method for measuring multiple dissolved gases.

The incorporation of multiple dissolved gas measurements in biogeochemical studies remains a difficult and expensive challenge. Incompatibilities in collection, handling, and storage procedures generally force the application of multiple sampling procedures for multiple gases. This paper introduces the concept and application of pumping-induced ebullition (PIE), a unified approach for routine measurement of multiple dissolved gases in natural waters and establishes a new platform for development of in situ real-time dissolved gas monitoring tools. Ebullition (spontaneous formation of bubbles) is induced by pumping a water sample through a narrow-diametertube (a "restrictor") to decrease hydrostatic pressure (PH) below total dissolved gas pressure (PT). Buoyancy is used to trap bubbles within a collection tower where gas accumulates rapidly (1 mL/min) to support multiple chemical analyses. Providing for field collection of an essentially unlimited and unified volume of gas sample, PIE afforded accurate and precise measurements of major (N2, 02, Ar), trace (CO2, N20, CH4) and ultratrace (CFC11, CFC12, CFC113, SF6) dissolved gases in Wisconsin groundwater, revealing interrelationships between denitrification, apparent recharge age-dates, and historical land use. Compared to conventional approaches, PIE eliminates multiple gas-specific sampling methods, reduces data computations, simplifies laboratory instrumentation, and avoids aqueous production and consumption of biogenic gases during sample storage. A lake depth profile for CO2 demonstrates PIE's flexibility as an in situ real-time platform for dissolved gas measurements. The apparent departures of some gases (SF6, H2, N2O, CO2) from solubility equilibrium behavior warrant further confirmation and theoretical investigation.

Carbon Dioxide↗

Possible cometary origin of heavy noble gases in the atmospheres of Venus, Earth and Mars

Models that trace the origin of noble gases in the atmospheres of the terrestrial planets (Venus, Earth and Mars) to the 'planetary component' in chondritic meteorites confront several problems. The 'missing' xenon in the atmospheres of Mars and Earth is one of the most obvious; this gas is not hidden or trapped in surface materials. On Venus, the absolute abundances of neon and argon per gram of rock are higher even than those in carbonaceous chondrites, whereas the relative abundances of argon and krypton are closer to solar than to chondritic values (there is only an upper limit on xenon). Pepin has developed a model that emphasizes hydrodynamic escape of early, massive hydrogen atmospheres to explain the abundances and isotope ratios of noble gases on all three planets. We have previously suggested that the unusual abundances of heavy noble gases on Venus might be explained by the impact of a low-temperature comet. Further consideration of the probable history of the martian atmosphere, the noble-gas data from the (Mars-derived) SNC meteorites and laboratory experiments on the trapping of noble gases in ice lead us to propose here that the noble gases in the atmospheres of all of the terrestrial planets are dominated by a mixture of an internal component and contribution from impacting icy planetesimals (comets). If true, this hypothesis illustrates the importance of impacts in determining the volatile inventories of these planets.

Argon↗

Effectiveness of selected chemicals for controlling emission of malodorous sulfur gases in sewage sludge.

The effectiveness of various oxidants or redox buffers (ferric chloride, sodium hypochlorite, potassium permanganate, hydrogen peroxide and potassium nitrate) for controlling or reducing emission of reduced sulfur gases (hydrogen sulfide, carbonyl sulfide, methanethiol, dimethyl sulfide and carbon disulfide) produced from sewage sludge collected from a wastewater treatment plant was studied under laboratory conditions. Sludge was treated with 0, 30, 300 and 1000 ppm of each chemical and changes in emission of the various reduced sulfur gases were monitored over a period of 24 hours. Potassium permanganate and hydrogen peroxide were shown to be the best chemicals for reducing hydrogen sulfide (the dominant reduced sulfur gas measured) emission. Sodium hypochlorite was also effective in reducing hydrogen sulfide emission followed by the ferric chloride addition. Since considerably smaller quantities of other reduced sulfur gases were evolved, the influence of the various chemical additions were not as significant as the reduction observed for hydrogen sulfide emission. Potassium permanganate and hydrogen peroxide were effective in reducing methanethiol and dimethyl sulfide emission. To a lesser degree sodium hypochlorite and ferric chloride also reduced emission of these two reduced sulfur gases. Potassium nitrate had no effect on reducing hydrogen sulfide or any of the reduced sulfur gases over the 24 hour experimental period. Each of the chemicals used in the study had a little or no effect in reducing carbonyl sulfide and carbon disulfide emission from the sludge material.

Air Pollution↗

Ambient levels of selected gases inside swine confinement buildings.

To assess potential worker health hazards, the air in confinement structures on 21 randomly selected swine producing farms in Iowa was evaluated for selected gases. The gases measured (mean concentration) included ammonia (34 ppm), hydrogen sulfide (1.4 ppm), carbon monoxide (9.1 ppm) and carbon dioxide (1640 ppm). Ammonia (compared to other gases) most commonly exceeded the Threshold Limit Value (TLV); however, it was common to find buildings with several gases in excess of the TLV. Buildings housing younger animals were more likely to have hazardous gas levels than buildings housing older animals. This complex mixture of gases represents a potential health hazard to an estimated 400,000 individuals who work in swine confinement buildings. These data suggest that research is needed to control these exposures affecting a large number of workers.

Agriculture↗