Search PubMedSearch

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Flow injection analysis of pharmaceuticals.

An overview of the most representative problems solved by flow injection analysis (FIA) in drug analysis is presented. Different aspects of this technique which can be manipulated with specific purposes are discussed and special emphasis is placed on the possibilities of FIA in dissolution test control.

Chemistry, Pharmaceutical

Determination of glutathione in biological material by flow-injection analysis using an enzymatic recycling reaction.

A sensitive and specific assay for glutathione using a recycling reaction followed by spectrophotometric detection in a flow-injection analysis system is presented. The proposed method provides specific amplification of the response to glutathione by combined use of the enzyme GSSG reductase and the chromogenic reagent 5,5'-dithiobis(2-nitrobenzoic acid). Both oxidized (GSSG) and reduced (GSH) glutathione are detected, so that GSSG must be determined separately after alkylation of the GSH with N-ethylmaleimide. The sensitivity is controlled by the number of times the cycle occurs and therefore by the residence time of the sample in the reactor. This time depends on the reactor length and the flow rate. The influence of residence time, temperature, and enzyme concentration on the response has been studied and the optimum reaction conditions have been selected. The sample throughput is as high as 30 h(-1) and the detection limit is 1 pmol GSH at a signal-to-noise ratio of 3. The method has been evaluated by the quantification of GSH and GSSG in isolated hepatocytes. A high correlation between the new flow-injection analysis method and the original spectrophotometric batch assay has been found (slope = 1.039, intercept = 0.6, n = 216, r = 0.977). The main advantages of the proposed method are high sample throughout, high sensitivity, and good reproducibility.

Animals

An amperometric flow-injection analysis biosensor for glucose based on graphite paste modified with tetracyanoquinodimethane.

A biosensor system using flow injection analysis (FIA) has been developed for the analysis of glucose in human serum. The system consists of the enzyme glucose oxidase incorporated into graphite paste modified with the electroactive material tetracyanoquinodimethane (TCNQ). TCNQ acts as an efficient mediator for oxidation of the reduced enzyme at 200 mV vs Ag/AgCl. The flow injection assay described has detection limits of 2 mM glucose using a 100-microliters sample injection through a 250-microliters sample loop. Data are presented to show the effect of sample injection volume and flow rate on the response of the FIA sensor. The biosensor exhibited excellent reproducibility for 800 injections. The loss of response after 800 injections was due to leaching of TCNQ from the graphite paste. Each assay takes 3 min giving a sample throughput of 20 per hour at a flow rate of 30 ml/h. The sensor was applied to the determination of glucose in human serum. The glucose measurements are in good agreement with those of a commercially available spectrophotometric method. Data showing the effect of interfering substances, ascorbic acid and acetaminophen, on the response of the sensor are also reported.

Acetaminophen

Determination of sulfite in food by flow injection analysis.

A method is described for the determination of sulfite levels in food products by flow injection analysis (FIA). The method is based on the decolorization of malachite green by SO2, which is isolated from the flowing sample stream by means of a gas diffusion cell. The FIA method has a detection limit in food sample extracts of 0.1 ppm SO2 (3 times peak height of blank), which corresponds to 1-10 ppm SO2 in a food product, depending on the extraction procedure used. At the 5 ppm SO2 level in a food extract, the precision of replicate injections is +/- 1-2%. The method was tested on a variety of both sulfite-treated and untreated food products and the results compared favorably with those obtained by the Monier-Williams, colorimetric (pararosaniline), and enzymatic (sulfite oxidase) methods. The average differences from the FIA results were 19, 11, and 12%, respectively, for those samples (n = 12) above 50 ppm SO2. At lower levels the results were somewhat more erratic due to inaccuracies of the various methods at low concentrations.

Colorimetry

Chemically coupled spectrophotometric assays based on flow injection analysis: determination of nitrogenase by assays for creatine, ammonia, hydrazine, phosphate, and dithionite.

Micromethods of direct chemical coupling have been developed for several different enzyme reactions, using the principles of flow injection analysis. Samples of 1-25 microliters are injected into a flowing stream of color-forming reagents and the peak of color change is measured after about 1 min. Alternatively, continuous slow infusion of a reacting system (5-100 microliters/min) gives a continuous change of color which can be monitored to derive enzyme reaction rates. These techniques are highly sensitive, requiring a few nanomoles of the substance being detected. Phosphate, ammonia, dithionite, creatine, and hydrazine have been measured. Consumption of reagents is less than 75 ml per hour; typical sample throughout is 30-40 samples per hour by the injection method, and 5 samples per hour by continuous infusion. The procedure has been applied to nitrogenase, continuously monitoring creatine produced from creatine phosphate by creatine kinase which is used to supply a constant level of ATP for nitrogenase. In this way nitrogenase activity can be determined over a wide range of enzyme concentrations. Production of inorganic phosphate directly from ATP, by injection of formaldehyde-quenched samples, was used when coupling to creatine kinase was not possible. Both injection of aliquots and continuous infusion were used for detection of hydrazine during nitrogenase reduction of azide, and the injection method has been used for ammonia assay during dinitrogen reduction. Dithionite oxidation was measured directly from decolorization of iodine, after trapping both dithionite and bisulfite with formaldehyde.

Ammonia

Control of microbial activity by flow injection analysis during high cell density cultivation of Escherichia coli.

The application of an automated flow injection analysis (FIA) system for on-line determination of microbial activity, during high cell density cultivations of Escherichia coli is reported. Based on a bioelectrochemical principle, the FIA method used a redox mediator (potassium hexacyanoferrate(III)) to facilitate electron transfer from the microorganisms to an electrochemical detector. Assays were carried out using a new sampling device which provided aseptic operation by use of a valve and chemical sterilisation. No sample dilution or pretreatment was necessary for biomass concentrations up to approx. 40 g l-1. The sample volume was 0.5 ml and the overall analysis time was 5 min. FIA signals were found to correlate well with the oxygen uptake rate (OUR). Changes in metabolic activity due to low substrate levels or high inhibitor concentrations in the cultivation medium became obvious from the FIA signals.

Bacteriological Techniques

Determination of free (pH 2.2) sulfite in wines by flow injection analysis: collaborative study.

A method for the determination of free sulfite in wine by flow injection analysis (FIA) is described. The method involves liberation of sulfur dioxide from the wine at pH 2.2, with detection by decolorization of a malachite green solution. The method was collaboratively studied, and the results indicated an average reproducibility of 12% for white wine samples (average level 12.1 ppm SO2) and 26% for red wine samples (average level 3.1 ppm). When the FIA method was compared to an aeration/oxidation method, the results indicated a high degree of correlation between the 2 methods. The FIA method has been adopted by AOAC official first action.

Hydrogen-Ion Concentration

Amperometric assay of creatinine in urine by flow injection analysis based on conjugated reactions of immobilized enzymes. Simultaneous compensation of endogenous ammonia.

A flow-injection analysis biosensor system was developed for the amperometric assay of creatinine based on coupled reactions of three immobilized enzymes, using an oxygen electrode as the detection device. The ammonia produced by creatinine deiminase-catalyzed hydrolysis of creatinine was further converted into L-glutamate with two sequentially aligned enzyme reactors: glutamate dehydrogenase and glutamate oxidase. Endogenous ammonia was simultaneously compensated with a double peak recording system, where the flow was split after sample injection and rejoined before the glutamate dehydrogenase reactor. The system gave linear calibration in a range of 0.1-2.0 mM for creatinine and the first peak of ammonia, and 0.1-3.0 mM for the second peak of ammonia. One run was completed within two minutes. The system can be readily applied to the assay of creatinine in urine and showed good correlation with that from the currently used Jaffe method.

Amino Acid Oxidoreductases

Determination of total CO2 in plasma by automated flow-injection analysis.

We describe a procedure for measuring total CO2 in plasma, based on the principles of the flow-injection analysis technique, which makes use of unsegmented fast-flowing reagent streams, as developed by Růziĉka and co-workers. The further methodological design resembles the silicone-rubber membrane technique of Kenny and Cheng. CO2 in the sample is released by reaction with H2SO4. Appropriate amounts of CO2 permeate through the membrane that separates the acid reagent streams and a buffered cresol-red indicator system. The experimental set-up and functioning of this system are described.

Autoanalysis

An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: determination of lactate in serum by flow injection analysis.

The electrochemical immobilization of lactate oxidase in a poly-o-phenylenediamine film permits the one-step and all-chemical construction of a lactate amperometric biosensor. The sensor was prepared in situ i.e. in the flow injection analysis (FIA) system by simply injecting a plug of a solution containing the monomer and the enzyme. At a flow rate of 50 microL/min linearity was observed up to 0.2 mM lactate and detection limits of about 2 microM could be easily achieved. Faradaic interferences caused by ascorbate, urate, cysteine and acetaminophen were sufficiently minimized to permit lactate determination in diluted serum by FIA. Results obtained by FIA-amperometric detection compared well (according to a proper t-test at a 95% confidence level) with those obtained by a standard enzymatic colorimetric assay. At a flow rate of 1 ml/min a sample throughput higher than 70 sample h-1 was achieved. After one week of continuous use in the FIA system a 75% decrease in biosensor sensitivity was observed.

Animals

Semiautomatic determination of furanic aldehydes in food and pharmaceutical samples by a stopped-flow injection analysis method.

A kinetic study of the reactions of 5-hydroxymethyl-2-furfuraldehyde and furfural with 2-thiobarbituric acid (TBA) by a stopped-flow flow injection analysis technique has been undertaken. A semiautomatic method for the analytical determination of these furanic aldehydes is proposed on the basis of reaction with TBA. The proposed stopped-flow method was successfully applied to several commercial pharmaceutical preparations and food samples. The procedure is faster than the earlier procedure for determination of these compounds in foods and pharmaceuticals.

Calibration

Use of ionomer membranes to enhance the selectivity of electrode-based biosensors in flow-injection analysis.

The use of ionomer membranes to enhance the selectivity of potentiometric enzyme electrodes in flow-injection measurement arrangements is examined. The ionomer membranes employed are permeable to analyte substrates but relatively impermeable to detectable ions that would normally interfere with the measurement of the substrates if the enzyme electrodes were in direct contact with the sample. As a model system, the selectivity of enzyme electrodes prepared with nonactin-based ammonium-sensitive polymeric membranes is evaluated. In the preferred configuration, a thin hydrophilic anion-exchange membrane is incorporated within a flow-through dialysis unit upstream from the enzyme-electrode detector. As the sample passes through the dialysis unit, neutral or anionic analyte molecules (urea or glutamine) move through the membrane while the permeation of endogenous ammonium ions and other cations in the sample is retarded. A flowing recipient buffer on the other side of the membrane carries the analyte substrate to the enzyme-electrode detector. Enhancements in selectivity for analyte substrates over endogenous ammonium and potassium ions are greater than or equal to 9-fold when compared to enzyme-electrode flow-injection analysis (FIA) systems assembled without the ionomer membrane unit. The analytical utility of the proposed system is demonstrated by the accurate measurements of urea in blood serum and L-glutamine in hybridoma bioreactor media.

Biosensing Techniques

Determination of urinary glucose by a flow injection analysis amperometric biosensor and ion-exchange chromatography.

A practical biosensor system has been developed for the determination of urinary glucose using a flow-injection analysis (FIA) amperometric detector and ion-exchange chromatography. Glucose oxidase was immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immobilized enzyme column. On the basis of its negative charge at pH 5.5, endogenous urate in urine samples was effectively retained by an upstream anion-exchange resin column. The biosensor system possessed a sensitivity of 160 +/- 2.4 RU microM-1 (RU or relative unit is defined as 2.86 microV at the detection output) for glucose with a minimum detection level of 10 microM. When applied for the determination of urinary glucose, the result obtained compared very well with that of the widely accepted hexokinase assay. The immobilized glucose oxidase could be reused for more than 1000 repeated analyses without losing its original activity. The reuse of the acetate anion-exchange column before replacement would be about 25-30 analyses. Acetaminophen and ascorbic acid were also effectively adsorbed by the acetate anion exchanger. The introduction of this type of anion exchanger thus greatly improved the selectivity of the FIA biosensor system and fostered its applicability for the determination of glucose in urine samples.

Adult

The glutamate biosensor and its application to flow injection analysis system.

A micro-enzyme electrode was fabricated by cross-linking L-glutamate oxidase with glutaraldehyde on aminopropyl-platinized platinum wire. A flow injection analysis system with glutamate sensor was used for L-glutamate determination. The peak current is linearly related to the L-glutamate concentration in the range of 0.02-2.0 mM, with good performance, accuracy (CV = 0.4%), fast response (< 60s), and stability (> 20 days). The system was applied to determine the concentration of L-glutamate in a fermentation broth. The recovery rate was in the range of 98.7-107.5%.

Amino Acid Oxidoreductases

Improved flow injection analysis (FIA) method for determining selenium in biological samples, and the effect of captopril administration on selenium levels and glutathione peroxidase activity in rat.

An improved flow injection analysis (FIA) method has been developed for the determination of trace selenium in biological samples, and this method has been applied to investigate the effect of captopril, an antihypertensive drug having a thiol group, on selenium concentrations in the rat blood, liver and urine. After oral administration of captopril, selenium levels in the blood decreased, while those in the liver increased significantly. However, no pronounced effect was observed on the urinary excretion rate. The glutathione peroxidase activities in the blood and the liver were comparable to the changes in the selenium levels.

Administration, Oral

Flow-injection analysis for malondialdehyde in plasma with the thiobarbituric acid reaction.

A simple, precise, and rapid method to measure plasma malondialdehyde (MDA) was developed by use of solvent extraction--flow-injection analysis. The reagent solution, containing thiobarbituric acid (TBA), 5 g/L in 100 mL/L phosphoric acid, and extraction solvent (methylisobutyl ketone, MIBK) were propelled with a double-plunger micropump at a flow rate of 0.3 mL/min, and 20 microL of sample was introduced into the reagent stream. After TBA-MDA reactant was extracted into MIBK, the organic phase was continuously separated by a successive phase-separation system equipped with two phase separators, and the absorbance of the TBA-MDA reactant was measured at 532 nm. This approach resulted in excellent sensitivity, a CV of < 1.5%, a good correlation with the conventional manual method, and a sampling frequency of 7 samples/h, suggesting that this semiautomated method is suitable for measuring plasma MDA.

Animals

Colorimetric determination of free and total cholesterol by flow injection analysis with a fiber optic detector.

A flow injection method for the determination of total and free cholesterol is presented. Cholesterol esterase and cholesterol oxidase are immobilized on aminoalkyl glass beads. The beads are packed into a tubular glass reactor. The cholesterol esters traversing through the esterase reactor are cleaved to cholesterol and fatty acids. The oxidase reactor converts cholesterol to cholest-4-en-3-one and hydrogen peroxide is generated. The sample stream is merged with reagent streams consisting of a peroxidase solution and a solution of 2,2'-azino-bis-(3-ethyl-benzthiazoline-6-sulfonic acid) diammonium salt, and a hydrogen peroxide-dependent color reaction takes place in a short coiled reactor. The signal is monitored by means of fiber optic instrumentation. Cholesterol concentration can be related to the absorption of the oxidized dye form at a wavelength of 425 nm. The working range is 0.5-0.8 mmol l-1, and the sample throughputs are 60 and 30 h-1 for free and total cholesterol, respectively.

Cholesterol

Development of a flow injection analysis (FIA) immunosensor for the detection of Escherichia coli.

A flow injection immunoanalysis (FIA) system has been developed for the detection of Escherichia coli in artificially contaminated food samples. Anti-E. coli antibodies were covalently immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immunoreactor. After adsorption of the cells onto anti-E. coli antibody bound glass beads, 4-methylumbelliferyl-beta-D-glucuronide was injected into the system which was then hydrolyzed by the adsorbed E. coli cells containing beta-D-glucuronidase, an enzyme which is very specific to E. coli and to a few other strains of Shigella. Fluorescent 4-methylumbelliferone released from the enzymatic reaction was then detected by a fluorometer. Owing to the specificity of the antibody towards E. coli, the FIA system was very selective for detection of E. coli whereas Shigella boydii, another GUD-positive bacterium, did not give any response. The FIA system was successfully used for detecting as low as 5 x 10(7) CFU/ml E. coli in less than 30 min and was reusable for at least 300 repeated assays. The immunoreactor yielded reproducible results during 3 months of experimentation if stored overnight at 4 degrees C in carrier buffer containing 0.05 to 0.25% Tween 20.

Escherichia coli