Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “FINGERS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Moving one's finger to a visually specified position: target orientation influences the finger's path.

It has previously been shown that, when subjects are instructed to move their finger slowly from one point to another the finger follows a path that deviates systematically from a straight line connecting the two points. The deviation depends on the angle between this fictive line and a line connecting the subject's finger with his body. In the present study, we examined whether the deviation also depends on the target's orientation. In two experiments, subjects were instructed to move a finger slowly towards five targets. We recorded the finger's movements. In one experiment, the targets were aligned. In the other, they were oriented radially around the starting point. Otherwise, conditions were the same. The difference in target orientation influenced the finger's path. Most importantly, when the targets were oriented radially around the starting point, the finger's path was straight. We conclude that pointing is more than moving the finger to a specified position.

Fingers↗

Localization of a seen finger is based exclusively on proprioception and on vision of the finger.

In a previous study we investigated how the CNS combines simultaneous visual and proprioceptive information about the position of the finger. We found that localization of the index finger of a seen hand was more precise (a smaller variance) than could reasonably be expected from the precision of localization on the basis of vision only and proprioception only. This suggests that, in localizing the tip of the index finger of a seen hand, the CNS may make use of more information than proprioceptive information and visual information about the fingertip. In the present study we investigate whether this additional information stems from additional sources of sensory information. In experiment 1 we tested whether seeing an entire arm instead of only the fingertip gives rise to a more precise proprioceptive and/or visual localization of that fingertip. In experiment 2 we checked whether the presence of a structured visual environment leads to a more precise proprioceptive localization of the index finger of an unseen hand. In experiment 3 we investigated whether looking in the direction of the index finger of an unseen hand improves proprioceptive localization of that finger. We found no significant effect in any of the experiments. The results refute the hypothesis that the investigated effects can explain the previously reported very precise localization of a seen hand. This suggests that localization of a seen finger is based exclusively on proprioception and on vision of the finger. The results suggest that these sensory signals may contain more information than is described by the magnitude of their variances.

Adult↗

Finger force vectors in multi-finger prehension.

In a majority of studies on grasp, only normal forces were measured and only when a zero torque was exerted on a hand-held object. This study concerns finger force vectors during the torque production tasks. Subjects (n=8) stabilized a handle with an attachment that allowed for change of external torque from -1.5 to 1.5 Nm. Forces and moments exerted by the digit tips on the object were recorded. At the large (>-0.375 Nm) supination torques the index/middle and ring/little pairs of fingers generated oppositely directed tangential forces. The index and middle finger produced forces in a downward direction and therefore did not support the load. At a zero torque and pronation torques, the middle, ring and little fingers produced forces along nearly the same direction. The vector of the index finger force was always directed differently from the vectors of other finger forces, the angles ranged from 19 degrees 30' to 47 degrees 40'. The points of force application were systematically displaced with the torque, with the exception of the little finger. Tangential finger forces contributed substantially to the total torque exerted on the hand-held object.

Adult↗

Anti-HIV agents that selectively target retroviral nucleocapsid protein zinc fingers without affecting cellular zinc finger proteins.

Agents that target the two highly conserved Zn fingers of the human immunodeficiency virus (HIV) nucleocapsid p7 (NCp7) protein are under development as antivirals. These agents covalently modify Zn-coordinating cysteine thiolates of the fingers, causing Zn ejection, loss of native protein structure and nucleic acid binding capacity, and disruption of virus replication. Concentrations of three antiviral agents that promoted in vitro Zn ejection from NCp7 and inhibited HIV replication did not impact the functions of cellular Zn finger proteins, including poly(ADP-ribose) polymerase and the Sp1 and GATA-1 transcription factors, nor did the compounds inhibit HeLa nuclear extract mediated transcription. Selectivity of interactions of these agents with NCp7 was supported by molecular modeling analysis which (1) identified a common saddle-shaped nucleophilic region on the surfaces of both NCp7 Zn fingers, (2) indicated a strong correspondence between computationally docked positions for the agents tested and overlap of frontier orbitals within the nucleophilic loci of the NCp7 Zn fingers, and (3) revealed selective steric exclusion of the agents from the core of the GATA-1 Zn finger. Further modeling analysis suggests that the thiolate of Cys49 in the carboxy-terminal finger is the site most susceptible to electrophilic attack. These data provide the first experimental evidence and rationale for antiviral agents that selectively target retroviral nucleocapsid protein Zn fingers.

Animals↗

Zinc-finger proteins: the classical zinc finger emerges in contemporary plant science.

TFIIIA-type zinc fingers have been found in a number of eucaryotic transcription factors as DNA-binding motifs. In plants, as many as 30 proteins have been reported that have either one, two, three or four zinc fingers. Plant zinc-finger proteins are characterized by long spacers of diverse lengths between adjacent fingers and a highly conserved sequence, QALGGH, located within a putative DNA-contacting surface of each finger. In vitro DNA-binding experiments with two-fingered proteins of petunia have revealed that these proteins bind to target DNA sequences in a manner that is distinctive from that of their animal counterparts: (1) they specifically recognize the spacing between two core sites in target DNA, (2) they have a unique base-determinant position. Regulatory functions have been assigned to some of the TFIIIA-type zinc finger proteins in Arabidopsis, petunia and chinese cabbage. SUPERMAN, AtZFP1, PetSPL3 and BcZFP1 have been implicated in the developmental regulation of various floral and vegetative organs, presumably through the control of cell division and/or expansion in particular cell types. Several anther-specific zinc-finger proteins in petunia are presumed to be involved in the regulation of gametogenesis in both reproductive and non-reproductive tissues of anther. STZ and ZPT2-2 are implicated in the response of plants to or tolerance for various stresses.

DNA-Binding Proteins↗

The KOX zinc finger genes: genome wide mapping of 368 ZNF PAC clones with zinc finger gene clusters predominantly in 23 chromosomal loci are confirmed by human sequences annotated in EnsEMBL.

The chromosome locations of 368 human Kruppel-type zinc finger (ZNF) PAC clones were physically mapped by FISH to human chromosomes in support of recent efforts of assigning KOX cDNAs (KOX1-KOX32) to zinc finger gene clusters. Recent mapping results were validated and confirmed by sequence comparisons to zinc finger gene sequences automatically annotated in EnsEMBL. In toto, 799 Kruppel-type zinc finger genes have been annotated in EnsEMBL of which 290 genes are found to encode KRAB domains. Sequence homologies of the zinc finger domains were used to establish phylogenic trees of KOX zinc finger genes as well as of all KRAB containing human zinc finger and KOX genes documenting the evolution of KRAB zinc finger genes late in primate evolution. A list of 368 assigned ZNF PAC clones is available under http://www.pzr.uni-rostock.de/supplements.

Base Sequence↗

Finger flexor tendon forces are a complex function of finger joint motions and fingertip forces.

In vivo tendon forces provide a view inside the musculoskeletal system revealing muscle function and potential injury etiologies. The studies presented here measured the in vivo tendon force of the flexor digitorum superficialis of the long finger during open carpal tunnel release surgery in ten adult patients. Forces were measured during passive movement of the finger, isometric pinch, and dynamic tapping of the finger. The tendon forces during passive movement of the finger were the largest with the finger fully extended. During isometric pinch, tendon force was linearly related to fingertip force, and was on average 3.3 times larger than the fingertip force. During dynamic activities, however, the relationship between tip and tendon force was nonlinear and often remained elevated when the finger was moving but with no applied force. Tendon forces were the highest with the isometric finger pinch. In conclusion, tendon force is a completed function of both fingertip load and motion of the joints that the tendons cross. A comparison of these results with others published in the literature indicated that rehabilitation processes need to incorporate a systems approach rather than rely on one specific physiologic relationship to minimize finger flexor tendon forces.

Biomechanical Phenomena↗

Lasso procedure to correct finger-clawing in leprosy using index or middle finger flexor digitorum superficialis split into four tails--a long-term follow-up study.

For obvious reasons, the use of flexor digitorum superficialis (FDS) from the ring finger, for correction of finger-clawing, is usually not recommended in leprosy. Hence, one has to choose either index or middle finger FDS for correction of finger-clawing. No significant differences could be made out when follow-up data of claw-finger correction by modified lasso procedure, using FDS either from index or middle finger, were compared. In some hands post-operative problems, such as stiffness, superficialis minus deformities of proximal interphalangeal joints (PIPJ) and distal interphalangeal joints (DIPJ), were noted. As revealed by finger dynamography, the working space of the hand was not found to be fully restored, the donor finger showing distortion of its working space.

Adolescent↗

Manual stretch: effect on finger movement control and force control in stroke subjects with spastic extrinsic finger flexor muscles.

This study evaluated the effects of manual stretch of extrinsic finger flexor muscles on finger extension movement control and force control in 16 spastic hemiparetic subjects. These subjects were randomly divided into a control group and an experimental group. A group of able-bodied subjects also participated. A joint-movement tracking test (JMTT) quantified control of active finger extension movement at the metacarpophalangeal joint of the index finger within the available range of active movement, and a force tracking test (FTT) quantified control of isometric finger extension force at the same joint within the subject's available force range. Electromyographic activity was monitored in the extensor digitorum and flexor digitorum superficialis muscles during both tracking tests. Manual stretch was applied to the extrinsic finger flexor muscles of the experimental group between the pretest and posttest tracking tests. The JMTT performances of both control (p less than .025) and experimental (p less than .05) groups were significantly subnormal on the pretest as were FTT performances of controls (p less than .01) and study subjects (p less than .03). The JMTT improvement on posttest was significantly greater (p less than .05) in subjects than in controls. However, the change in FTT performance was not significantly different between the two groups. Manual stretch treatment, properly applied to extrinsic finger flexor muscles, is an effective method of temporarily improving the control of finger extension movement in spastic hemiparetic subjects.

Cerebrovascular Disorders↗

[The deepithelialized cross-finger flap: a good method for covering large dorsal finger defects].

BACKGROUND: Injuries to the dorsum of the finger are common. Combination with exposure of important deeper structures needs reconstruction with a flap. The deepithelialized cross-finger flap is a good possibility for covering large dorsal finger defects. PATIENTS AND METHODS: From March 2003 to October 2003 six patients (two female, four male) underwent this procedure. RESULTS: Neither flap loss nor infection was observed. All defects were covered adequately, and no donor site problems occurred. One week after flap division, the function of the involved finger joints had the same range of motion as the contralateral finger joints. CONCLUSION: The deepithelialized cross-finger flap is a good and safe method for defect cover in large dorsal finger defects. The good postoperative range of motion supports the indication for this two-step reconstruction procedure.

Adult↗

Donor finger morbidity in cross-finger flaps.

We reviewed 16 patients who had cross-finger flap procedures carried out between 1991 and 1996 at the West Midlands Regional centre for Plastic and Reconstructive Surgery. We looked specifically at the donor finger morbidity of each patient with a median follow up interval of 43 months.At follow up there were 10 patients with cold intolerance, eight patients with subjective joint stiffness and a documented reduced range of finger joint movement. Skin graft reconstruction of the secondary defect was associated with poor colour match in eight cases (seven hyperpigmented, one hypopigmented) and visible contour deformity in eight cases. There were no clinically significant differences between split skin graft or full thickness skin graft for donor finger reconstruction. Although cross-finger flaps may provide soft tissue cover in a variety of finger pulp injuries, these results show an alarming incidence of donor finger morbidity associated with such procedures.

Adolescent↗

Reproducibility of phalanx osteosonography and relation with forearm peripheral quantitative computed tomography: single finger versus average measurement on the last four fingers.

The aim of this study was to evaluate the in vivo short-term reproducibility of amplitude-dependent speed of sound (AD-SOS) measured at the proximal phalanx, using an Igea DBM Sonic 1200 device, as well as its relationship with bone mineral density of the ultradistal radius, assessed using peripheral quantitative computed tomography (pQCT). In particular, the authors wished to evaluate whether average measurements on the last four fingers, as recommended by the manufacturer, yielded or not more information than measurements on one single finger. For the precision study, the authors carried out phalanx osteosonography ten times once every other day in ten healthy young women. To compare with pQCT of the radius, 37 women referred for screening of osteoporosis (mean age 60 years) were studied. AD-SOS was reported for each finger separately, as well as an average; pQCT (XCT 960 Stratec) yielded trabecular (BMDt); cortical (BMDc); and total (BMDtot) bone mineral densities, as well as the cortical area (Ac). The reproducibility of AD-SOS was significantly higher for the middle finger (mean coefficient of variation (CV) 1.1%) and the index than for the ring and small (mean CV 2.7%) finger. The middle finger consistently showed the best correlations with pQCT variables; the relationships involving BMDc (r = 0.54), BMDtot (r = 0.62) and Ac (r = 0.61) were stronger than that with BMDt (r = 0.34). The authors conclude that phalanx AD-SOS is moderately correlated with BMD of the ultradistal radius--at least when it includes the cortical component--and that reporting AD-SOS for the middle finger--instead of an average value--improves the reproducibility and possibly the relevance of phalanx osteosonography.

Adult↗

The influence of intrinsic sympathomimetic activity and beta-1 receptor selectivity on the recovery of finger skin temperature after finger cooling in normotensive subjects.

A double-blind randomized study was designed to investigate differences in the recovery of finger skin temperature after finger cooling during dosing with placebo or one of four beta-blockers: propranolol, atenolol, pindolol, and acebutolol. In 11 normotensive nonsmoking subjects, finger skin temperature was measured with a thermocouple before and 20 minutes after immersion of one hand in a water bath at 16 degrees C. This finger cooling test caused no significant changes in systemic hemodynamics such as arterial blood pressure, heart rate, and forearm blood flow. The recovery of finger skin temperature during propranolol dosing was better than that during pindolol and atenolol dosing. There were no differences between the recoveries of skin temperature during pindolol, atenolol, and acebutolol dosing. Thus we could demonstrate no favorable effect of intrinsic sympathomimetic activity or beta 1-selectivity on the recovery of finger skin temperature after finger cooling.

Acebutolol↗

The structure of the C4C4 ring finger of human NOT4 reveals features distinct from those of C3HC4 RING fingers.

The NOT4 protein is a component of the CCR4.NOT complex, a global regulator of RNA polymerase II transcription. Human NOT4 (hNOT4) contains a RING finger motif of the C(4)C(4) type. We expressed and purified the N-terminal region of hNOT4 (residues 1-78) encompassing the RING finger motif and determined the solution structure by heteronuclear NMR. NMR experiments using a (113)Cd-substituted hNOT4 RING finger showed that two metal ions are bound through cysteine residues in a cross-brace manner. The three-dimensional structure of the hNOT4 RING finger was refined with root mean square deviation values of 0.58 +/- 0.13 A for the backbone atoms and 1.08 +/- 0.12 A for heavy atoms. The hNOT4 RING finger consists of an alpha-helix and three long loops that are stabilized by zinc coordination. The overall folding of the hNOT4 RING finger is similar to that of the C(3)HC(4) RING fingers. The relative orientation of the two zinc-chelating loops and the alpha-helix is well conserved. However, for the other regions, the secondary structural elements are distinct.

Amino Acid Motifs↗

Cysteine residues in the zinc finger and amino acids adjacent to the finger are necessary for DNA binding by the LAC9 regulatory protein of Kluyveromyces lactis.

LAC9 is a positive regulatory protein that controls transcription of the lactose-galactose regulon in Kluyveromyces lactis. LAC9 is homologous to the GAL4 protein of Saccharomyces cerevisiae. Both proteins have a single "zinc finger" which plays a role in DNA binding. We previously hypothesized (L. V. Wray, M. M. Witte, R. C. Dickson, and M. I. Riley, Mol. Cell. Biol. 7:1111-1121, 1987) that the DNA-binding domain of the LAC9 protein consisted of the zinc finger as well as a region of amino acids on the carboxyl-terminal side of the zinc finger. In this study we used oligonucleotide-directed mutagenesis to introduce 13 single-amino-acid changes into the proposed DNA-binding domain of the LAC9 protein. Variant LAC9 proteins carrying an amino acid substitution in any one of the four highly conserved Cys residues of the zinc finger had reduced DNA-binding activity, suggesting that each Cys is necessary for DNA binding. Three of four variant LAC9 proteins with amino acid substitutions located on the carboxyl-terminal side of the zinc finger had reduced DNA-binding activity. These results support our hypothesis that the DNA-binding domain of the LAC9 protein is composed of the zinc finger and the adjacent region on the carboxyl side of the zinc finger, a region that has the potential to form an alpha-helix. Finally, LAC9 proteins containing His residues substituted for the conserved Cys residues also had reduced DNA-binding activity, indicating that His residues are not equivalent to Cys residues, as had been previously thought.

Amino Acid Sequence↗

The NH2-terminal fibrin-binding site of fibronectin is formed by interacting fourth and fifth finger domains. Studies with recombinant finger fragments expressed in Escherichia coli.

The NH2-terminal 29-kDa Fib-1 fragment consisting of the first five finger modules of fibronectin (F1-5) binds reversibly to fibrin and facilitates cross-linking by Factor XIII. To narrow down the fibrin-binding site within this region, we have used recombinant technology to express a number of individual fingers, rF1, rF2, rF3, rF4, and rF5, and their pairs, rF1-2 rF2-3, and rF4-5, as fusion proteins in Escherichia coli. These recombinant fragments were separated from the carrier maltose-binding protein by digestion with human factor Xa or other proteases, and their structural integrity was confirmed by spectroscopic and calorimetric methods. The recombinant F1 and F4-5 exhibited fluorescence-detected melting transitions of the same magnitude and with the same midpoint (Tm) as their natural analogues prepared from Fib-1 by proteolysis. Differential scanning calorimetry experiments further demonstrated that these fragments are properly folded and have compact structures identical to the natural ones. Isolated rF4 melts at a much lower temperature than rF5 or the bimodular fragment rF4-5, indicating the loss of a stabilizing interaction between fingers 4 and 5. Comparison of fluorescence spectra of individual rF4 and rF5 with that of rF4-5 was also consistent with an interaction that affects the environment of Trp residue(s). rF2 also melts at a lower temperature than rF3 or rF2-3, suggesting a stabilizing interaction between the second and third fingers as well. When tested on fibrin-Sepharose, only the bimodular fragment rF4-5 was able to bind. All other fragments, including individual fingers 4 and 5, failed to bind. Thus, fibrin binding is not a common property of all fingers. The results indicate that a recognition site for fibrin is located within fingers 4 and 5. The interaction between these neighboring domains may play an important role in proper orientation of the residues forming this site.

Amino Acid Sequence↗

Effects of keyswitch design and finger posture on finger joint kinematics and dynamics during tapping on computer keyswitches.

OBJECTIVE: To examine the effects of postural and keyswitch characteristics on musculoskeletal tissue loading during tapping on computer keyswitches. DESIGN: We hypothesized that joint torques, stiffness and work parameters differ across keyswitch designs and finger postures typical of those observed during computer keyboard typing. We experimentally measured joint kinematics and calculated joint torques while tapping on different keyswitches in different postures, and analyzed the data using mechanical impedance models. METHODS: Sixteen human subjects tapped with the index finger on computer keyswitches mounted on a sensor which measured vertical and horizontal forces. Miniature electro-optical goniometers mounted dorsally across each finger joint measured joint kinematics. Joint torques were calculated from endpoint forces and joint kinematics using an inverse dynamics algorithm. A linear spring-damper impedance model was fitted to joint torque, position, and velocity during the contact period of each tap. Subjects tapped in three postures approximating those employed during tapping on three rows of a computer keyboard, on four different keyswitches, resulting in 12 conditions. RESULTS: More extended finger posture was associated with greater joint torques, energies, and stiffnesses, despite minimal differences in endpoint forces across posture. Greater keyswitch make forces were associated with increased forces, joint torques and joint stiffnesses, however this relationship was not monotonic. CONCLUSIONS: Joint torques and stiffness parameters differed across keyswitch designs and finger postures. Estimates of joint impedance and work provided a unique perspective into finger dynamics. RELEVANCE: Determining the causes of work-related musculoskeletal disorders is facilitated by characterizing workplace task biomechanics, which can be linked to specific injury mechanisms.

Adult↗

Crystal structure of a five-finger GLI-DNA complex: new perspectives on zinc fingers.

Zinc finger proteins, of the type first discovered in transcription factor IIIA (TFIIIA), are one of the largest and most important families of DNA-binding proteins. The crystal structure of a complex containing the five Zn fingers from the human GLI oncogene and a high-affinity DNA binding site has been determined at 2.6 A resolution. Finger one does not contact the DNA. Fingers two through five bind in the major groove and wrap around the DNA, but lack the simple, strictly periodic arrangement observed in the Zif268 complex. Fingers four and five of GLI make extensive base contacts in a conserved nine base-pair region, and this section of the DNA has a conformation intermediate between B-DNA and A-DNA. Analyzing the GLI complex and comparing it with Zif268 offers new perspectives on Zn finger-DNA recognition.

Amino Acid Sequence↗