Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Diamond”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

A diamond detector in the dosimetry of high-energy electron and photon beams.

A diamond detector type 60003 (PTW Freiburg) was examined for the purpose of dosimetry with 4-20 MeV electron beams and 4-25 MV photon beams. Results were compared with those obtained by using a Markus chamber for electron beams and an ionization chamber for photon beams. Dose distributions were measured in a water phantom with the detector connected to a Unidos electrometer (PTW Freiburg). After a pre-irradiation of about 5 Gy the diamond detector shows a stability in response which is better than that of an ionization chamber. The current of the diamond detector was measured under variation of photon beam dose rate between 0.1 and 7 Gy min(-1). Different FSDs were chosen. Furthermore the pulse repetition frequency and the depth of the detector were changed. The electron beam dose rate was varied between 0.23 and 4.6 Gy min(-1) by changing the pulse-repetition frequency. The response shows no energy dependence within the covered photon-beam energy range. Between 4 MeV and 18 MeV electron beam energy it shows only a small energy dependence of about 2%, as expected from theory. For smaller electron energies the response increases significantly and an influence of the contact material used for the diamond detector can be surmised. A slight sublinearity of the current and dose rate was found. Detector current and dose rate are related by the expression i alpha Ddelta, where i is the detector current, D is the dose rate and delta is a correction factor of approximately 0.963. Depth-dose curves of photon beams, measured with the diamond detector, show a slight overestimation compared with measurements with the ionization chamber. This overestimation is compensated for by the above correction term. The superior spatial resolution of the diamond detector leads to minor deviations between depth-dose curves of electron beams measured with a Markus chamber and a diamond detector.

Diamond↗

Influence of electrodes on the photon energy deposition in CVD-diamond dosimeters studied with the Monte Carlo code PENELOPE.

A new dosimeter, based on chemical vapour deposited (CVD) diamond as the active detector material, is being developed for dosimetry in radiotherapeutic beams. CVD-diamond is a very interesting material, since its atomic composition is close to that of human tissue and in principle it can be designed to introduce negligible perturbations to the radiation field and the dose distribution in the phantom due to its small size. However, non-tissue-equivalent structural components, such as electrodes, wires and encapsulation, need to be carefully selected as they may induce severe fluence perturbation and angular dependence, resulting in erroneous dose readings. By introducing metallic electrodes on the diamond crystals, interface phenomena between high- and low-atomic-number materials are created. Depending on the direction of the radiation field, an increased or decreased detector signal may be obtained. The small dimensions of the CVD-diamond layer and electrodes (around 100 microm and smaller) imply a higher sensitivity to the lack of charged-particle equilibrium and may cause severe interface phenomena. In the present study, we investigate the variation of energy deposition in the diamond detector for different photon-beam qualities, electrode materials and geometric configurations using the Monte Carlo code PENELOPE. The prototype detector was produced from a 50 microm thick CVD-diamond layer with 0.2 microm thick silver electrodes on both sides. The mean absorbed dose to the detector's active volume was modified in the presence of the electrodes by 1.7%, 2.1%, 1.5%, 0.6% and 0.9% for 1.25 MeV monoenergetic photons, a complete (i.e. shielded) (60)Co photon source spectrum and 6, 18 and 50 MV bremsstrahlung spectra, respectively. The shift in mean absorbed dose increases with increasing atomic number and thickness of the electrodes, and diminishes with increasing thickness of the diamond layer. From a dosimetric point of view, graphite would be an almost perfect electrode material. This study shows that, for the considered therapeutic beam qualities, the perturbation of the detector signal due to charge-collecting graphite electrodes of thicknesses between 0.1 and 700 microm is negligible within the calculation uncertainty of 0.2%.

Diamond↗

Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.

The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK ionization chamber. Measurements included output factors (OF). percentage depth doses (PDD) and dose profiles. OFs measured with diamond detector agreed within 1% with those measured with diode and RK chamber. Only at 25 MV, for the smallest field size, RK chamber underestimated OFs due to averaging effects in a pointed shaped beam profile. Agreement was found between PDDs measured with diamond detector and RK chamber for both 6 MV and 25 MV photons and down to 5 cm x 5 cm field size. For the 2.6 cm x 2.6 cm field size, at 25 MV, RK chamber underestimated doses at shallow depth and the difference progressively went to zero in the distal region. PDD curves measured with silicon diode and diamond detector agreed well for the 25 MV beam at all the field sizes. Conversely, the nontissue equivalence of silicon led, for the 6 MV beam, to a slight overestimation of the diode doses in the distal region, at all the field sizes. Penumbra and field width measurements gave values in agreement for all the detectors but with a systematic overestimate by RK measurements. The results obtained confirm that ion chamber is not a suitable detector when high spatial resolution is required. On the other hand, the small differences in the studied parameters, between diamond and silicon systems, do not lead to a significant advantage in the use of diamond detector for routine clinical dosimetry.

Diamond↗

[Practical application of diamond points in mucosalplasty of edentulous ridges].

In order to establish a new operative method of mucosalplasty in the edentulous ridges to improve pontic adaptation, newly revised diamond points were produced and tested. The efficiency of these diamond points were tested on the edentulous ridges of dogs in relation to its shape, size of the diamond particle, and appropriate rotational speed, and the tissue damages and healing processes were observed under a light microscope and SEM. The results were as follows: 1. Light microscopic observations showed immediate post operative necrosis of the wound surface, and degeneration below the necrosed layer of high rotational speed diamond points. 2. Tissue damage became larger as the size of the diamond particle increased, but there appeared to be no influence upon the healing process of the wound. 3. Tissue damage also became larger as the diameter of the diamond point increased, but again no influence upon the healing process was observed. 4. Middle to low rotational speeds showed no differences in tissue damage or wound healing, but high rotation caused larger tissue damage and prolongation in the healing process. 5. The most suitable condition for mucosalplasty revealed the size of the diamond particle to be 200 microns, and rotational speed to be between 12,000-20,000 rpm.

Alveoloplasty↗

Surface roughness of resin composite prepared by single-use and multi-use diamonds.

PURPOSE: To compare the surface roughness of a resin composite caused by two 30- and 40-microm, multi-use finishing diamonds with two 30- and 40-microm, single-use finishing diamonds of comparable grit size before and after steam sterilization. METHODS: Resin composite specimens 6 mm in diameter and 3 mm in depth were light cured. Surface roughness (Ra, microm) of surfaces formed by Mylar, after finishing with a bur, and after polishing with fine and superfine aluminum oxide disks was measured for the as-received and after sterilization conditions with a surface profilometer. RESULTS: Ra of Mylar surfaces (baseline) ranged from 0.02-0.05 microm. Ra of surfaces prepared with 30-microm diamond burs ranged from 1.42-1.90 microm. Ra of surfaces prepared with 40-microm diamond burs ranged from 2.22-2.42 microm. Ra of surfaces polished sequentially with fine and superfine aluminum oxide disks ranged from 0.07-0.11 microm in the as-received condition and from 0.12-0.14 microm in the sterilized condition. Sterilization and reuse of all types of diamond finishing burs resulted in equal or rougher resin composite surfaces after final polish when compared to final polish surfaces that were initially finished with as-received diamonds. CLINICAL SIGNIFICANCE: Surface roughness of a resin composite prepared with single- and multi-use diamond finishing burs was equivalent when compared at the final polish.

Analysis of Variance↗

Photochemical functionalization of hydrogen-terminated diamond surfaces: a structural and mechanistic study.

Hydrogen-terminated diamond surfaces can be covalently modified with molecules bearing a terminal vinyl (C=C) group via a photochemical process using sub-band-gap light at 254 nm. We have investigated the photochemical modification of hydrogen-terminated surfaces of nanocrystalline and single-crystal diamond (111) to help understand the structure of the films and the underlying mechanism of photochemical functionalization. A comparison of the rates of photochemical modification of single-crystal diamond and nanocrystalline diamond films shows no significant difference in reactivity, demonstrating that the modification process is not controlled by grain boundaries or other structures unique to polycrystalline films. We find that both single-crystal and polycrystalline hydrogen-terminated diamond samples exhibit negative electron affinity and are functionalized at comparable rates, while oxidized surfaces with positive electron affinity undergo no detectable reaction. Gas chromatography-mass spectrometry (GC-MS) analysis shows the formation of new chemical products in the liquid phase that are formed only when the alkenes are illuminated in direct contact with H-terminated diamond, while control experiments with other surfaces and in the dark show no reaction. Our results show that the functionalization is a surface-mediated photochemical reaction and suggest that modification is initiated by the photoejection of electrons from the diamond surfaces into the liquid phase.

Journal Article↗

Origin of the metallic properties of heavily boron-doped superconducting diamond.

The physical properties of lightly doped semiconductors are well described by electronic band-structure calculations and impurity energy levels. Such properties form the basis of present-day semiconductor technology. If the doping concentration n exceeds a critical value n(c), the system passes through an insulator-to-metal transition and exhibits metallic behaviour; this is widely accepted to occur as a consequence of the impurity levels merging to form energy bands. However, the electronic structure of semiconductors doped beyond n(c) have not been explored in detail. Therefore, the recent observation of superconductivity emerging near the insulator-to-metal transition in heavily boron-doped diamond has stimulated a discussion on the fundamental origin of the metallic states responsible for the superconductivity. Two approaches have been adopted for describing this metallic state: the introduction of charge carriers into either the impurity bands or the intrinsic diamond bands. Here we show experimentally that the doping-dependent occupied electronic structures are consistent with the diamond bands, indicating that holes in the diamond bands play an essential part in determining the metallic nature of the heavily boron-doped diamond superconductor. This supports the diamond band approach and related predictions, including the possibility of achieving dopant-induced superconductivity in silicon and germanium. It should also provide a foundation for the possible development of diamond-based devices.

Journal Article↗

DNA-modified nanocrystalline diamond thin-films as stable, biologically active substrates.

Diamond, because of its electrical and chemical properties, may be a suitable material for integrated sensing and signal processing. But methods to control chemical or biological modifications on diamond surfaces have not been established. Here, we show that nanocrystalline diamond thin-films covalently modified with DNA oligonucleotides provide an extremely stable, highly selective platform in subsequent surface hybridization processes. We used a photochemical modification scheme to chemically modify clean, H-terminated nanocrystalline diamond surfaces grown on silicon substrates, producing a homogeneous layer of amine groups that serve as sites for DNA attachment. After linking DNA to the amine groups, hybridization reactions with fluorescently tagged complementary and non-complementary oligonucleotides showed no detectable non-specific adsorption, with extremely good selectivity between matched and mismatched sequences. Comparison of DNA-modified ultra-nanocrystalline diamond films with other commonly used surfaces for biological modification, such as gold, silicon, glass and glassy carbon, showed that diamond is unique in its ability to achieve very high stability and sensitivity while also being compatible with microelectronics processing technologies. These results suggest that diamond thin-films may be a nearly ideal substrate for integration of microelectronics with biological modification and sensing.

Base Sequence↗

Evaluation of the dosimetric characteristics of a diamond detector for photon beam measurements.

The dosimetric properties of a new diamond detector for the measurement of relative dose in photon beams have been investigated and compared to those of a silicon p-type photon diode and a 0.14 cm3 ionization chamber. The mass energy absorption ratio of carbon to water is nearly constant over a wide energy range making the diamond detector nearly tissue equivalent. The directional dependence of the radiation response of the diamond detector for cobalt 60, 6 MV and 18 MV photon beams was more uniform than that of the diode. As the incident photon beam moves from 0 degree (parallel to the detector stem) to a direction transverse to the detector stem (90 degrees), the diamond detector sensitivity remains nearly uniform whereas the diode sensitivity diminishes by approximately 15%-22%. The spatial resolution of the diamond detector, as measured by penumbra width, is slightly less than that of the diode detector but clearly superior to that of the 0.14 cm3 ionization chamber. The tissue maximum ratio measurements for small size photon fields (diameter < or = 4 cm) with the diamond, diode, and a Markus parallel plate chamber are in excellent agreement. The diamond detector with high radiation sensitivity and spatial resolution is an excellent choice as a detector in photon fields with high dose gradients such as brachytherapy and radiosurgery.

Humans↗

[Relation of surface texture of fine finishing diamond point for composite resin and polished surface of composite resin].

Distribution of diamond grain size of seven fine finishing diamond points was measured by a digital image analyzer. Also influence of diamond grain size of fine finishing diamond points on finished surface of two types of visible light cured composite resins (semihybrid type and submicron filler type) were investigated. Diamond grain size was almost from 10 to 100 microns 2 in area. Diamond grain size was closely related to the surface roughness of semihybrid type composite resin, although it was not related to that of submicron filler type composite resin. Surface roughness of a submicron filler type composite resin finished at a low speed was less than that at a high speed. Grain size of diamond point and revolution speed may play an important role in surface texture of composite resin.

Composite Resins↗

Diamond laser scalpel vs. steel scalpel: a side by side comparison of cutaneous wound healing.

BACKGROUND AND OBJECTIVES: To compare the cutaneous wound healing using the diamond laser scalpel with wound healing using a steel scalpel and electrocoagulation for hemostasis. STUDY DESIGN/MATERIALS AND METHODS: A prospective and randomized, comparative trial was conducted on eighteen patients. Fusiform excisions were performed using the diamond laser scalpel on one half of each excision and a steel scalpel with electrocoagulation for hemostasis on the other half. The Clinicon SureBlade diamond laser scalpel was used with the Luxar CO(2) attachment at the 6-8-W settings. Blinded assessment of adverse events and photographs were taken at 1 day, 7-10 days, 4 weeks, and 8-12 weeks. The final scar was evaluated at 8-12 weeks for cosmetic outcome and three physicians blinded to the method of excision evaluated photographs of the wounds. Histologic evaluation was performed on all excisions for collateral thermal damage. RESULTS: Investigator assessment showed no statistically significant differences between the diamond laser scalpel side and the steel scalpel side with respect to bleeding, bruising, swelling, pain, dehiscence, or final scar appearance. The mean residual thermal damage was 350.3 microm (95% CI +/- 37 microm, P < 0.001). The diamond laser scalpel scored higher on intra-operative coagulation (P = 0.20) although these differences were not statistically significant. CONCLUSIONS: The cosmetic outcomes of cutaneous excisions performed with the diamond laser scalpel are equivalent to excisions performed with steel scalpels with electrocoagulation for hemostasis.

Cicatrix↗

Biocompatibility of chemical-vapour-deposited diamond.

The biocompatibility of chemical-vapour-deposited (CVD) diamond surfaces has been assessed. Our results indicate that CVD diamond is as biocompatible as titanium (Ti) and 316 stainless steel (SS). First, the amount of adsorbed and 'denatured' fibrinogen on CVD diamond was very close to that of Ti and SS. Second, both in vitro and in vivo there appears to be less cellular adhesion and activation on the surface of CVD diamond surfaces compared to Ti and SS. This evident biocompatibility, coupled with the corrosion resistance and notable mechanical integrity of CVD diamond, suggests that diamond-coated surfaces may be highly desirable in a number of biomedical applications.

Absorption↗

Benign response to particles of diamond and SiC: bone chamber studies of new joint replacement coating materials in rabbits.

Wear particles from total joint replacements are thought to accelerate prosthetic loosening. Diamond coating may improve the smoothness and wear characteristics of the femoral head component of total hip replacements, and thus increase their longevity. The brittleness of a thin diamond coat may be overcome by using an SiC-whisker diamond composite. This study describes the reactions of regenerating bone tissue to phagocytosable particles of diamond and SiC, using implanted bone harvest chambers in rabbits. The particles were dispersed in hyaluronan and introduced into a canal transversing the implant. The tissue that entered the canal during the following 3 weeks was then harvested. In previous studies using this model, particles of high density polyethylene, bone cement and chromium-cobalt all caused an inflammatory reaction and a marked decrease in the amount of ingrown bone. In the present study, neither the diamond nor the SiC particles caused any decrease in bone formation. It appears that particles of diamond and SiC are comparatively harmless.

Animals↗

Dental diamond burs made with a new technology.

STATEMENT OF PROBLEM: Conventional diamond burs show several limitations such as the heterogeneity of grain shapes, the difficulty of automation during fabrication, the decrease of cutting effectiveness due to repeated sterilization, and short lifetime. An additional shortcoming may be represented by the potential release of Ni+2 ions from the metallic binder into the body fluids. PURPOSE: This study investigated a new diamond rotative instrument made of a continuous diamond film obtained by chemical vapor deposition (CVD). This bur, characterized by a pure diamond cutting surface without metallic binder between crystals, was compared with a conventional diamond bur. MATERIAL AND METHODS: Cutting tests were followed by SEM examination and electron microprobe analysis (EMA) to trace metallic residues both at the surface of the bur and the substrate. RESULTS: EMA demonstrated that the metals Ni, Cr, Si, and Fe were present in the metallic binder matrix of the conventional bur and could be smeared on the surface of the substrate during cutting. SEM showed that significant loss of diamond particles occurred during cutting. On the other hand, no discrete particles sheared off the CVD bur. The smearing of the metallic binder cannot occur using the new bur. CONCLUSION: The new CVD bur not only proves to be more efficient in its cutting ability and longevity, but also excludes the risk of metal contamination. This last aspect concerns both the pollution of the oral environment and the contamination of the ceramic during the laboratory manufacturing of dental restorations.

Dental Instruments↗

Electrochemical detection of carbamate pesticides at conductive diamond electrodes.

Conductive boron-doped diamond thin-film electrodes were used for the electrochemical detection of selected N-methylcarbamate pesticides (carbaryl, carbofuran, methyl 2-benzimidazolecarbamate, bendiocarb) after liquid chromatographic separation. Two kinds of detection methods were adopted in this study. In the first method, a direct detection of underivatized pesticides was carried out at an operating potential of 1.45 V versus Ag/AgCl, which resulted in the detection limits of 5-20 ng/mL (or 5-20 ppb) with S/N = 2 due to the low background current and wide potential window of the diamond electrode. In the second method, the detection limits were improved by subjecting the pesticide samples to alkaline hydrolysis in a separate step prior to injection. The phenolic derivatives obtained by alkaline hydrolysis oxidize at a relatively lower potential (0.9 V vs Ag/AgCl), which increases the sensitivity drastically. The advantage of the diamond electrode for the detection of phenolic derivatives is that it offers excellent stability in comparison to other electrodes. This method gives the detection limits of 0.6-1 ng/mL (or 0.6-1 ppb), which are well below the maximum residue levels allowed for carbaryl, carbofuran, and bendiocarb. While the lowest detection limits (LOD) obtained by the direct detection of pesticides are comparable to the those reported by the well-established HPLC-fluorescence, the LODs of the alkaline hydrolysis method are found to be even lower than the reported limits. On-line reactivation of the diamond electrode surface was shown to be possible by an anodic treatment of the electrode at approximately 3 V for 30 min in case of electrode fouling, which may occur after a prolonged use. Such a treatment damages the glassy carbon (GC) and metal electrodes, while the diamond electrode remains stable. These results suggest that the diamond electrode is superior to the other previously used electrodes such as GC and Kelgraf type for highly sensitive and stable detection of carbamate pesticides.

Carbamates↗

Monocrystalline diamond paste-based electrodes and their applications for the determination of Fe(II) in vitamins.

A new class of electrochemical sensors, namely, electrodes based on diamond paste, was designed using monocrystalline diamond (natural diamond 1 microm and synthetic diamond, 50 microm (synthetic-1) and 1 microm (synthetic-2)) powder and paraffin oil. The characterization of the electrodes was performed using cyclic voltammetry and differential pulse voltammetry. Fe(II) was determined by differential pulse voltammetry (DPV) at 75 mV (vs Ag/AgCl) using all diamond paste-based electrodes. The linear concentration range was between 10(-8) and 10(-4) mol/L for both the natural diamond and synthetic-2 with detection limits of 10(-10) and 10(-9) mol/L, respectively, whereas the linear concentration range for synthetic-1 was between 10(-7) and 10(-3) mol/L with a detection limit of 10(-8) mol/L Fe(II) was determined successfully from four types of pharmaceutical products. The recovery values of Fe(II) in the pharmaceutical products were higher than 98.00% with relative standard deviation values < 5%.

Carbon↗

Polylysine-coated diamond nanocrystals for MALDI-TOF mass analysis of DNA oligonucleotides.

A protocol based on aminated diamond nanocrystals has been developed to isolate, concentrate, purify, and digest DNA oligonucleotides in one microcentrifuge tube for matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry. It is shown that use of diamond nanocrystals as a solid-phase extraction support not only permits concentration of oligonucleotides in highly diluted solutions but also facilitates separation of oligonucleotides from proteins in heavily contaminated solutions. Enzymatic digestions can be conducted on particle, and additionally, the digests can be easily recovered from the solution for base sequencing. In this method, the aminated diamond nanocrystals ( approximately 100 nm in diameter) were prepared by noncovalent coating of carboxylated/oxidized diamonds with poly(L-lysines) (PL), which form stable complexes with DNA oligonucleotides. While the complexes are sufficiently stable to sustain repeated washing with deionized water, the DNA molecules can be readily eluted after incubation of the diamond adducts in aqueous ammonium hydroxide at elevated temperatures. No preseparation of PL or diamond nanocrystals is required for subsequent MALDI-TOF mass analysis.

Adsorption↗

Electrochemical oxidation of histamine and serotonin at highly boron-doped diamond electrodes.

The electrochemistry of histamine and serotonin in neutral aqueous media (pH 7.2) was investigated using polycrystalline, boron-doped diamond thin-film electrodes. Cyclic voltammetry, hydrodynamic voltammetry, and flow injection analysis (FIA) with amperometric detection were used to study the oxidation reactions. Comparison experiments were carried out using polished glassy carbon (GC) electrodes. At diamond electrodes, highly reproducible and well-defined cyclic voltammograms were obtained for histamine with a peak potential at 1.40 V vs SCE. The voltammetric signal-to-background ratios obtained at diamond were 1 order of magnitude higher than those obtained for GC electrodes at and above 100 microM analyte concentrations. A linear dynamic range of 3-4 orders of magnitude and a detection limit of 1 microM were observed in the voltammetric measurements. Well-defined sweep rate-dependent voltammograms were also obtained for 5-hydroxytryptamine (5-HT). The characteristics of the voltammogram indicated lack of adsorption of its oxidation products on the surface. No fouling or deactivation of the electrode was observed within the experimental time of several hours. A detection limit of 0.5 microM (signal-to-noise ratio 13.8) for histamine was obtained by use of the FIA technique with a diamond electrode. A remarkably low detection limit (10 nM) was obtained for 5-HT on diamond by the same method. Diamond electrodes exhibited a linear dynamic range from 10 nM to 100 microM for 5-HT determination and a range of 0.5-100 microM for histamine determination. The FIA response was very reproducible from film to film, and the response variability was below 7% at the actual detection limits.

Boron↗