Search PubMedSearch

SEARCH · Search PubMed

Results for “Clips”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Clip with enclosed spring for aneurysm surgery. Technical note.

A clip for aneurysm surgery has been designed with several unique features. The coil spring is fully hidden and protected within two hub sections so that it cannot be handled or become entrapped in tissue. The clip is milled from a piece of solid stock of nonmagnetic stainless steel to the desired size and shape by a computer milling process, thus avoiding the stresses and structural weaknesses caused by the bending, curling, and milling needed to prepare clips made from wire or sheet metal. The only means of opening the clip is by applying pressure to the solid milled surfaces, thus the spring cannot be weakened or bent by squeezing it or by trauma applied to the clip. The clip may be grasped in either a clip applier that holds the clip in one fixed position or in an applier that allows the clip to be rotated through an arc of 180 degrees.

Aneurysm

Laparoscopic clips. Evaluation of absorbable and titanium with regard to hemostasis and tissue reactivity.

Advanced laparoscopic techniques require laparoscopic means of providing hemostasis. We tested the hemostatic ability of laparoscopic surgical clips and their tissue reactivity as assessed by adhesion formation in an animal model. Twenty-six New Zealand white rabbits were randomized at laparotomy to one of three treatment groups: titanium surgical clips, absorbable surgical clips (both applied with a laparoscopic clip applicator) and chromic sutures of equal mass. Either the right fallopian tube was transected, with clips or sutures applied proximally and distally to control bleeding, or the clips or sutures were applied 5 mm apart and the tube transected. A clip or suture of the same material was placed on the midportion of the left fallopian tube. Necropsy was performed at 42 days, and each clip/suture site was scored for adhesions. All the materials were easily applied and effective in achieving hemostasis. The adhesion scores tended to be lower with the absorbable clips; however, there were no statistically significant differences between the groups. Laparoscopic clips are effective in providing hemostasis, are easily applied and cause no more adhesion formation than do conventional suture materials.

Animals

[Is tubal sterilization with the Tupla-clip a reversible method?].

Between 1976 and 1981 402 tubal sterilizations were performed with Tupla-clip most of them by laparoscopic application. 11 tubes were removed between 15 and 47 months following the sterilization with the Tupla-clip. The local changes both macroscopically and microscopically to the tupla-clip were evaluated. The possibility of tubal patency following removal of the clips was tested by carbon dioxide pertubation. The tubal-occlusion with the tupla-clip is definitive since all tubes had a fibrous tissue strand where the clip had been applied which still carried blood vessels. No tube was patent with the carbon dioxide pertubation. The intra-operative testing of correct application of the clip and the documentation of this correct application is again mentioned. This is especially important in view of the recent judgements of the federal supreme court regarding liability in failed tubal sterilizations. The excellent chance of reversal by tubal anastomosis and the 100% success rate of this method of sterilization within the 6 years under observation will increase the acceptance of the tupla-clip as a method for tubal sterilizations.

Female

Surgical clips in planning the electron boost in breast cancer: a qualitative and quantitative evaluation.

PURPOSE: To evaluate, qualitatively and quantitatively, the role of surgical clips in planning the tumor bed electron boost in patients undergoing breast conserving surgery and radiotherapy. METHODS AND MATERIALS: In 50 patients, the excision cavity boundaries were marked by clips at surgery. The electron boost field was first planned using clinical information, aiming to achieve a margin of 2 cm, and its accuracy evaluated by screening the surgical clips and, if necessary, adjusting the field to encompass all clips with 2 cm margins. Orthogonal radiographs were take with solder wire delineating the clinical and screened fields and the scar. Hypothetical clinical and radiological fields, with 1 and 3 cm margins, were reconstructed on the radiographs. RESULTS: The clinical field was inadequate in 34 patients (68%). The precision of each clinical setup was quantified by two indices. The Normal Tissue Index defined the percentage of the clinical field comprised of tissue, beyond the tumor bed, not at high risk of local recurrence, and gave an estimate of potential spring of normal tissue: median 14.6% (range 0-83.0), 17 out of 50 > 25%; median 13% (range 0-70.7), 12 out of 50 > 25%; median 9.7% (range 0-59.8), 10 out of 50 > 25%, for 1, 2, and 3 cm margins, respectively. The Geographical Miss Index defined the percentage of the radiologically defined field, at high risk of local recurrence, not predicted by the clinical field, and gave an estimate of the extent of geographical miss: median 32.9% (range 0-83.5), 28 out of 50 > 25%; median 26.1% (range 0-69.8%), 26 out of 50 > 25%; median 18.6% (range 0-60.3), 20 out of 50 > 25%, for 1, 2, and 3 cm margins, respectively. The median distance from the scar midpoint to the furthest clip was 3.8 (range 1.2-8.1) cm. The median maximal clip depth was 3.1 (range 1.4-5.2) cm. CONCLUSION: (a) Electron boost field planning by clinical landmarks alone was inaccurate in 68% of cases. (b) Quantitative measures, based on margins of 1, 2, and 3 cm, revealed that in 20-34% of patients more than one-quarter of the clinical field covered tissue at low risk of local recurrence, and in 40-56% of patients less than three-quarters of the final radiological field was predicted clinically. (c) The relative positions of the scar and clips may be widely disparate. (d) Clip depth measurements reveal a significant risk of underdosing at depth.

Breast Neoplasms

Aggravation of experimental glomerulonephritis by superimposed clip hypertension.

To evaluate the possible enhancing effect of hypertension on the clinical and morphologic features of glomerulonephritis, two-kidney clip hypertension (CH) was superimposed on a mild form of nephrotoxic serum nephritis (NSN) in female Sprague-Dawley rats. The following parameters were assessed regularly over a 6-month period: blood pressure (BP), heart weight, proteinuria (UpV), and renal morphology. Blood pressure and heart weights were increased equally in clip hypertension and in nephrotoxic serum nephritis combined with clip hypertension. While only moderate proteinuria occurred in nephrotoxic serum nephritis (49 +/- 28 mg/24 hr) or clip hypertension (40 +/- 22 mg/24 hr) alone, the superimposition of clip hypertension on nephrotoxic serum nephritis resulted in heavy proteinuria (161 +/- 36 mg/24 hr) (P less than 0.001) after 5 months of hypertension. Glomerular histology in nephrotoxic serum nephritis showed infrequent focal and segmental proliferation and minimal sclerosis; vessels were normal. Clip hypertension was characterized by infrequent and mild vascular sclerosis and glomerular proliferation and sclerosis. Severe glomerular endo- and extracapillary proliferation and widespread glomerular and vascular sclerosis occurred in the majority of rats when nephrotoxic serum nephritis was combined with clip hypertension. The data demonstrate that clip hypertension enhances glomerular proliferation and sclerosis and results in the development of vascular sclerosis in experimental nephritis.

Animals

Effects of saralasin infusion on bilateral renal function in two-kidney, one-clip Goldblatt hypertensive rats.

1. Previous studies have shown that administration of converting enzyme inhibitor (CEI, SQ 20 881) to two-kidney, one-clip Goldblatt hypertensive (GH) rats clipped for 3-4 weeks resulted in marked increases in glomerular filtration rate (GFR), water and sodium excretion by the non-clipped kidneys. The clipped kidneys exhibited reduced function that was due, in part, to the reductions in arterial pressure. To evaluate further the hypothesis that the renal responses to CEI were due primarily to the inhibition of angiotensin II rather than other factors, we infused the angiotensin II competitive blocker, saralasin, into GH rats under sodium pentobarbital anaesthesia and examined renal haemodynamics and excretory function of each kidney before and during saralasin infusion and after cessation of saralasin infusion. 2. Saralasin reduced mean arterial blood pressure from 164 +/- 4 to 124 +/- 4 mmHg. Despite the profound fall of arterial pressure, significant increases in renal blood flow from 5.82 +/- 0.22 to 9.15 +/- 0.76 ml/min and glomerular filtration rate from 1.46 +/- 0.10 to 2.18 +/- 0.14 ml/min were observed in the non-clipped kidneys. Renal vascular resistance decreased from 2.34 (+/- 0.14) x 10(5) to 1.17 (+/- 0.19) x 10(5) kPa 1(-1) s [2.34 (+/- 0.14) x 10(6) to 1.17 (+/- 0.19) x 10(6) dyn s cm-5]. Also, concomitant diuresis and kaliuresis and a delayed natriuresis occurred. 3. The clipped kidneys exhibited reductions in renal blood flow, GFR and excretory function during saralasin infusion. 4. Normal rats receiving the identical dose of saralasin responded with a slight but significant decrease in arterial pressure. The increase in renal blood flow and GFR were less than those observed in the non-clipped kidneys of hypertensive rats. 5. These data provide further support to the hypothesis that an angiotensin II-mediated elevation in renal vascular resistance and impairment of renal function exist in the non-clipped kidneys of GH rats.

Angiotensin II

The importance of the renin-angiotensin system in the development and maintenance of hypertension in the two-kidney one-clip hypertensive rat.

1. Blood pressure, renin concentration and angiotensin II were measured in unanaesthetized two-kidney one-clip hypertensive rats at 1 and 2 days, at weekly intervals up to 10 weeks and at 15 and 20 weeks after clipping. 2. Compared with values in sham-operated rats, renin and angiotensin II were initially increased at 1-2 days but were then suppressed between 2 and 4 weeks to levels similar to that found in sham-operated rats. Between 5 and 20 weeks renin and angiotensin II increased again to high levels. 3. There was a significant correlation between angiotensin II and blood pressure in acute rats 1-2 days after clipping (P less than 0.05) and in chronic rats 8-20 weeks after clipping (P less than 0.001). There was no difference in the slope of the regression lines but the regression line for the chronic rats was shifted upwards in a parallel manner. 4. The acute hypotensive response (-20.3 +/- SD 24.9 mmHg) in 26 chronic rats given converting enzyme inhibitor was related to the basal renin and angiotensin II levels and followed the slope of the angiotensin II/blood pressure regression line for all chronic rats. Only one out of 26 rats reduced its blood pressure to normal levels. 5. In 12 rats at 4 weeks after clipping, when blood pressure was elevated but angiotensin II was suppressed, there was only a small fall in blood pressure (-7.1 +/- SD 7.2 mmHg). This also followed the angiotensin II/blood pressure regression line for chronic rats but at the lower end. Blood pressure again was not reduced to normal. 6. These results suggest that renin and angiotensin II are increased up to 20 weeks after clipping, that there is no change in the net vascular responsiveness to endogenous angiotensin II at any stage in this experimental model and that the acute effect of angiotensin II is determined solely by its position in the same dose-response curve. Also with the exception of 1-2 days immediately after clipping the acute effect of angiotensin II plays only a minor, though variable, role in the hypertension and that some other mechanism, as yet undetermined, is of greater importance and begins to have an effect as early as 2 weeks after clipping.

Angiotensin II

Effects of verapamil and converting enzyme inhibition on bilateral renal function of two-kidney, one-clip hypertensive rats.

Experiments were conducted in two-kidney, one-clip renal vascular hypertensive rats (GHR) to assess the responses of each kidney to acute treatment with the antihypertensive calcium channel blocking agent verapamil in the presence and in the absence of converting enzyme inhibitor (CEI). One group of GHR (0.2 mm inner diam. clip 3 weeks before study) were examined during a control period, and during a second period of infusion of verapamil (600 micrograms h-1 kg-1). A second group of GHR were examined during a control period, during CEI (teprotide, 3 mg h-1 kg-1) infusion and during a third period of verapamil (600 micrograms h-1 kg-1) infusion superimposed on CEI infusion. Although systemic blood pressure (BP) decreased from 175 +/- 4 to 149 +/- 5 mmHg (mean +/- SEM) in response to verapamil alone, renal blood flow for non-clipped kidneys increased from 5.9 +/- 0.4 to 6.5 +/- 0.3 ml/min, indicating a 30% reduction of renal vascular resistance (P values less than or equal to 0.01; n = 9). Glomerular filtration rate (GFR) for non-clipped kidneys (n = 24) increased from 0.91 +/- 0.09 to 1.47 +/- 0.14 ml/min and filtration fraction increased from 0.32 +/- 0.04 to 0.47 +/- 0.03 (P values less than or equal to 0.05). Urine flow rate and absolute and fractional sodium excretion for non-clipped kidneys increased. GFR for clipped kidneys decreased during verapamil. Treatment with CEI alone resulted in nearly identical responses of BP and function of the non-clipped kidney, except filtration fraction was unchanged. The addition of verapamil to ongoing converting enzyme blockade tended to augment the increased GFR of the non-clipped kidney. Plasma renin activity (PRA) increased from 30 +/- 3 to 59 +/- 7 ng of angiotensin (ANG) I h-1 ml-1 with verapamil alone, a significantly larger increment than the increase of PRA from 27 +/- 5 to 39 +/- 9 ng of ANG I h-1 ml-1 in GHR subjected to comparable blood pressure reduction by mechanical aortic constriction. Verapamil resulted in many similar effects on renal function to those observed during blockade of converting enzyme. The increased filtration fraction observed in response to verapamil may be the result of vasodilatation of the afferent arteriole or of an increase in the glomerular ultrafiltration coefficient.

Angiotensin II

Chronic angiotensin converting enzyme inhibition in the two-kidney, one clip hypertensive rat.

Treatment with an angiotensin converting enzyme (ACE) inhibitor in renovascular hypertension produces acute effects on renal function; however, the long-term consequences of this are not known. We have studied the effect of chronic enalapril treatment on renal structure and function in the two-kidney, one clip model of renovascular hypertension in the rat. Four weeks after the left renal artery was clipped, the hypertensive rats were randomly allocated to treatment with enalapril, minoxidil or to no treatment. The drug dose was titrated for maximal hypotensive effect. After 4 months of treatment blood pressures were 129 +/- 3 mmHg (enalapril), 193 +/- 5 mmHg (minoxidil) and 220 +/- 4.8 mmHg (no treatment). Twelve months later survival was 84% (enalapril group), 48% (minoxidil group) and 15% (untreated group). Split kidney function (51Cr-EDTA clearance, ml/min) of the clipped kidneys was 0.0 (enalapril group), 0.26 +/- 0.23 (minoxidil group) and 0.74 +/- 0.13 (untreated group). The clipped kidney from enalapril-treated rats weighed 0.46 +/- 0.1 g, much less than in the minoxidil-treated group (1.2 +/- 0.07) or the untreated group (1.14 +/- 0.10). Enalapril treatment was withdrawn for 2 weeks in five rats, but the clipped kidney remained small and non-functional. Histological examination revealed marked interstitial fibrosis and tubular atrophy in clipped kidneys from both enalapril groups, in contrast to minor changes in the minoxidil-treated and the untreated groups. We conclude that chronic enalapril treatment of two-kidney, one clip hypertension in the rat improved survival and preserved total renal function, but was associated with irreversible fibrotic atrophy of the clipped kidney.

Angiotensin-Converting Enzyme Inhibitors

Prevention of two-kidney, one-clip renal hypertension in rat by ablation of AV3V tissue.

This study examined the role of the anteroventral third ventricle (AV3V) in the renin-dependent two-kidney, one-clip model of renal hypertension. AV3V lesion and sham lesion rats were subjected to the placement of a clip on one renal artery or a sham operation. The sham lesion-renal artery clip rats experienced an increase in systolic blood pressure; however, AV3V lesioned animals experienced only a transient rise in arterial pressure during the 1st wk after clip. Body fluid regulation studies during the course of the hypertension revealed that there were no differences in water intake and urine volume between the lesion- and sham lesion-renal artery clip animals. Although significantly greater plasma and blood volumes were demonstrated in the AV3V lesion-sham clip rats compared with sham lesion animals, no differences in vascular volumes were detected in the renal artery clip rats. Finally, the rats were water deprived for 3 days to maximally stimulate vasopressin release. Urine osmolality increased significantly in all groups of rats except the AV3V lesion-renal artery clip animals protected against the hypertension.

Animals

Renal atrial peptide receptors and natriuresis in two-kidney, one clip hypertension.

It has been suggested that the impaired natriuretic response of the clipped kidney in two-kidney, one clip hypertensive rats is related to downregulation of renal atrial natriuretic peptide receptors. To test this hypothesis, blood volume expansion and atrial peptide binding studies were performed in this model. Infusion of 1% and then 1.5% body weight donor blood (n = 6) caused a progressive increase in plasma immunoreactive atrial natriuretic peptide (107 +/- 26 to 168 +/- 31 to 427 +/- 154 pg/ml, p less than 0.001); the sodium excretion of the nonclipped kidney rose from 230 to 2,200 to 4,000 neq/min (p less than 0.01) but that of the clipped kidney did not rise significantly. There was a highly significant correlation between log cyclic guanosine monophosphate and log sodium excretion by the nonclipped (r2 = 0.749) but not the clipped (r2 = 0.046) kidney. Between clipped and nonclipped kidneys, the association constant (5.26 +/- 0.89 versus 5.17 +/- 0.64 x 10(9)/mol) and apparent binding site density (575 +/- 92 versus 500 +/- 74 fmol/mg protein) for atrial peptide binding in isolated glomeruli did not differ. Assay of atrial peptide-induced cyclic guanosine monophosphate release by isolated glomeruli showed that clipped and nonclipped kidneys were equally responsive. Binding affinity and receptor density did not differ in homogenates prepared from inner medullas of clipped and nonclipped kidneys. These results show that the blunted natriuretic response in clipped kidneys was not associated with any relative decrease in number or function of glomerular or papillary atrial natriuretic peptide receptors.

Animals

Lack of evidence for the participation of tonin in the pathogenesis of one-kidney, one-clip renovascular hypertension.

It has been reported that immunization against tonin normalizes blood pressure, and that sialoadenectomy, during which the tonin-rich salivary glands are removed, decreases blood pressure in one-kidney, one-clip hypertension. To investigate the role of tonin on this form of hypertension further, we actively immunized one-kidney, one-clip hypertensive rabbits with tonin and measured both the blood pressure response and the titer of antibodies raised against tonin. In addition, because sialoadenectomy may alter food intake, we assessed the effect of sialoadenectomy on the blood pressure of one-kidney, one-clip hypertensive rats fed a liquid diet to facilitate eating. After immunization, all rabbits developed antitonin-antibody titers ranging from 1:300 to 1:56,000. However, in none of the rabbits did the blood pressure decrease significantly (114 +/- 3 mm Hg before immunization; 129 +/- 6 mm Hg at 16 weeks after immunization). In one-kidney, one-clip hypertensive rats, sialoadenectomy did not lower blood pressure (179 +/- 5 mm Hg before sialoadenectomy; 202 +/- 9 mm Hg 3 weeks after sialoadenectomy). Neither blood pressure nor body weight differed between sialoadenectomy and sham-sialoadenectomy one-kidney, one-clip hypertensive rats (n = 6). In conclusion, neither active immunization against tonin in one-kidney, one-clip hypertensive rabbits nor sialoadenectomy in one-kidney, one-clip hypertensive rats significantly reduced established hypertension. These results do not support the hypothesis that tonin is involved in the pathogenesis of one-kidney, one-clip hypertension in these animal models.

Animals

Aneurysm clip motion during magnetic resonance imaging: in vivo experimental study with metallurgical factor analysis.

Because of various mechanical, metallurgical, and commercial constraints, aneurysm clips are manufactured from different alloys, including several stainless steel and cobalt alloys. Some of the steels contain volume fractions of the crystal phase known as martensite. Martensitic alloys have body-centered cubic structure, are prone to stress corrosion failure, and are ferromagnetic. Martensitic steel can be displaced like a compass needle when exposed to a magnetic field such as that generated during magnetic resonance imaging (MRI). The force exerted by the magnetic field is proportional to the volume fraction of the magnetic phase. We investigated the martensitic content and magnetic field-induced displacement of 12 common aneurysm clips. Four clips of each of the following types were examined: Sugita, Sundt-Kees Multi-Angle, Heifetz (two types), Vari-Angle McFadden, Yasargil (two types), Scoville, Mayfield, Vari-Angle, Pivot, and Kapp. Phase homogeneity and crystal structure were analyzed by x-ray diffraction using a Phillips x-ray diffractometer. Clip deflection in an Oxford Research Systems MRI spectrometer was measured in our in vivo rat abdominal aortic aneurysm model. Results showed that the volume fraction of the martensitic phase in the various clips correlated with the magnitude of the deflection. Among the clips examined, the Yasargil, Sugita, Heifetz Elgiloy, and Vari-Angle McFadden had a nonmartensitic composition and did not deflect in the magnetic field. The Scoville contained 5% martensite and deflected only marginally. Martensite comprised 35% of the Mayfield clip, which deflected 45 degrees, and 90% of the Heifetz, Vari-Angle, Pivot, and Sundt-Kees Multi-Angle clips, which deflected approximately 70 degrees or slipped off the aneurysm.(ABSTRACT TRUNCATED AT 250 WORDS)

Alloys

Acute phase vascular endothelial injury: a comparison of temporary arterial occlusion using an endovascular occlusive balloon catheter versus a temporary aneurysm clip in a pig model.

We compared the degree of acute endothelial injury after temporary vessel occlusion using two different occlusion modalities--external clipping and endovascular balloon occlusion. The common carotid and subclavian arteries in eight weanling pigs were temporarily occluded with either a 5 Fr occlusion balloon catheter or a temporary microvascular clip for 0 (control), 5, 10, and 30 minutes. Two animals (eight vessels; four clip and four balloon occluded) were used at each time interval. Segments of each experimental vessel were harvested and analyzed by scanning electron microscopy. Each vessel specimen was graded on the following scale: Grade 1 showed no evidence of injury; Grade 2 showed minimal evidence of endothelial cell injury; Grade 3 showed moderate evidence of endothelial cell injury; Grade 4 showed marked evidence of endothelial cell injury; Grade 5 showed severe endothelial and subendothelial injury. Control vessels showed no evidence of injury. Grade 2 injuries were seen in both clip- and balloon-occluded vessels at 5 minutes. At 10 minutes, focal Grade 2 and 3 injuries were appreciated in the clip group, with diffuse Grade 2 and 3 injuries in the balloon group. After the 30-minute occlusion, the balloon group showed Grade 2, 3, and 4 injuries, whereas the clip group showed entirely Grade 2 injuries. The degree of injury with either occlusion modality was equivalent and worsened with time. However, clip-occluded vessels displayed injury that was confined to an area closely adjacent to the clip site, whereas balloon-occluded vessels demonstrated a more widespread injury centered around the balloon site.

Animals

Molecular characterization of two functional domains of CLIP-170 in vivo.

CLIP-170 is a microtubule-binding protein isolated from HeLa cells that is involved in the interaction of endosomes with microtubules. The basic N-terminal domain of CLIP-170 binds to microtubules in vitro. To characterize further the functional domains of this cytoplasmic linker protein, we have transiently expressed intact and mutant forms of CLIP-170 in mammalian cells (HeLa and Vero cells) and show that the tandem repeat present in the N-terminal domain is essential for its binding to microtubules in vivo as previously found in vitro. With increasing levels of expression of CLIP-170, the sites with which the peripheral ends of microtubules interact enlarge, eventually forming large patches, which finally lead to the apparent bundling of microtubules. These patches do not form when the C-terminal domain is absent from the transfected protein. Modification of the microtubule-binding region, particularly of the tandem repeat motif, modulates the binding of CLIP-170 to microtubules. Overexpressed CLIP-170 appears neither to interact with nor to influence the organization of the intermediate filaments, and collapsing the network of intermediate filaments with microinjected antibodies against vimentin has no effect on the distribution of CLIP-170. These data suggest that CLIP-170 has at least two functional domains in vivo, an N-terminal microtubule-binding domain, and a C-terminal domain that is involved in the anchoring of microtubules to peripheral cytoplasmic structures.

Amino Acid Sequence

Booster clips for giant and thick-based aneurysms.

The authors describe their experience using booster clips to secure the closure of primary clips in the repair of giant and other thick-walled aneurysms. These clips were used for 21 aneurysms in 20 patients, comprising 12% of all aneurysms operated on during the 15-month period of the report, but representing about 50% of all giant aneurysms operated on during the same time frame. These clips are designed to encircle the primary clip and have fixation "shoes" to close upon the jaws of the primary clip. All aneurysms were opened for decompression and thrombectomy when necessary following temporary major vessel occlusion before placement of the primary clip. Cerebral blood flow measurements and continuous electroencephalographic monitoring were utilized to predict the brain's tolerance to temporary ligation of the internal carotid artery (ICA) in those cases with a giant aneurysm arising from that vessel. There were no complications attributable to the periods of intracranial or cervical ICA occlusion; these periods varied but did not exceed 8 minutes for the former nor the tolerance period for the latter, which was calculated as from 5 to 30 minutes. It was necessary to reoperate on two patients and reposition clips because of stenoses or occlusions identified on immediate postoperative angiography. Fifteen patients had normal neurological function at the time of discharge. Three patients had minor deficits which did not prevent employment; two of these were related to a preoperative deficit and one was a complication of delayed ischemia. There were two deaths: one from bleeding complications and probable damage to perforating vessels in a patient operated on under profound hypothermia (the only case in the series so managed), and one from respiratory complications in a patient with severe pulmonary problems.

Adult

Magnetic resonance imaging and aneurysm clips. Magnetic properties and image artifacts.

The magnetic properties of 12 different types of aneurysm clip were investigated in order to identify which clips allow postoperative magnetic resonance (MR) imaging without risk. Clip-induced MR artifacts were also quantitatively studied using a geometrical phantom. Nonferromagnetic aneurysm clips like the Yaşargil Phynox, Sugita Elgiloy, and Vari-Angle McFadden clips do not appear to contraindicate MR studies performed with a FONAR beta-3000M imager. There is no clip movement upon introduction of the phantom into the MR imager, and the image artifacts caused by the clips are so limited that patients harboring such clips may well be considered for MR imaging. This examination may reveal information not obtainable by any other radiological modality.

Aneurysm

[An evaluation of temporary clipping during aneurysmal surgery: a retrospective study].

A temporary clipping of a parent artery has been found convenient in facilitating an aneurysmal dissection. This is because it controls the bleeding from an unexpected rupture and keeps the sac collapsed during the operation. Such a temporary arterial occlusion, however, involves the risk of a focal ischemia that may lead to permanent postoperative neurological deficits. Therefore, to evaluate the influence of a temporary clipping on the outcome of an operation, a retrospective study of 302 patients who underwent an operation for a ruptured supratentorial aneurysm between 1981 and 1990 has been conducted. This study has revealed the information that follows: 1) Overall outcomes In patients given no temporary clipping, their postoperative activity in daily living (ADL) grade was good in 70.7%, i.e. ADL 1 or 2, whereas only 46.4% of the patients given a temporary clipping achieved a similar ADL. 2) Influence of the preoperative Hunt and Kosnik neurological classification on the outcome Irrespective of whether a temporary clip had been used, patients with a Hunt and Kosnik grade of 1 or 2 made a good recovery, whereas patients with a grade of 4 or 5 did not. The application of a temporary clip in grade 3 patients led to a poor result, whereas in grade 3 patients given no temporary clipping the results were good. This would seem to indicate that Hunt and Kosnik grade 3 rating is a critical factor in consideration whether a temporary clip should be used or not. 3) Influence of the operative timing on the outcome.(ABSTRACT TRUNCATED AT 250 WORDS)

Activities of Daily Living