Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cardiac Output”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Spontaneous gasping generates cardiac output during cardiac arrest.

OBJECTIVES: To measure stroke volumes coincident with spontaneous gasping during untreated ventricular fibrillation and to evaluate the effects of gasping. DESIGN: Prospective study in laboratory animals. SETTING: University-affiliated research institute. SUBJECTS: Male Yorkshire-X domestic pigs. INTERVENTIONS: Pigs were anesthetized (ketamine, 20 mg/kg intramuscularly and sodium pentobarbital, 30 mg/kg intravenously), intubated, and mechanically ventilated. Ventricular fibrillation was electrically induced and untreated for 7 mins. The right femoral artery and vein were cannulated. A 5.5/7.5-MHz biplanar transesophageal echocardiography transducer was advanced into the esophagus. MEASUREMENTS AND MAIN RESULTS: Stroke volumes were measured as the product of the transaortic blood flow velocity and transesophageal echocardiographic measurements of valve area. In addition, left ventricular volumes were echocardiographically estimated at peak inspiration and at peak expiration of each gasp by transesophageal methods. The stroke volume produced by gasping averaged 23 +/- 6 mL, which represented approximately 60% of a precardiac arrest stroke volume (38 +/- 8 mL, p <.001). Increases in end-tidal carbon dioxide tension coincident with each gasp were consistent with comparable increases in pulmonary blood flow and therefore stroke volumes. Both were associated with increases in aortic pressure from 20 +/- 3 to 33 +/- 8 mm Hg (p <.001) and coronary perfusion pressure from 4 +/- 3 to 13 +/- 7 mm Hg (p <.001). CONCLUSIONS: Our studies confirm that preterminal gasping during ventricular fibrillation increases both ventilation and forward blood flow.

Animals↗

Recurrent gastrointestinal bleeding and high output cardiac failure caused by hereditary hemorrhagic telangiectasia.

Hereditary hemorrhagic telangiectasia, commonly known as Osler-Weber-Rendu disease, is a systemic autosomal dominant inherited disorder, that occurs in Caucasian populations. We report the case of a 56-year-old housewife who was admitted to the gastrointestinal and cardiovascular ward because she had suffered from recurrent gastrointestinal bleeding and heart failure from 1994 to 1997. Panendoscopy showed vascular ectasia scattered over the tongue, larynx, esophagus, and posterior wall of the gastric body. Colonoscopy showed clusters of telangiectasia over the cecum and ascending colon. Arteriovenous malformations (AVMs) were found in the liver and lungs on computerized tomography. Recurrent gastrointestinal bleeding was controlled by estrogen treatment during the follow-up period. In July 1997, the patient was readmitted to our cardiovascular section due to aggravated dyspnea, orthopnea and bilateral lower leg edema. Cardiac catheterization showed a large fistula from the left pulmonary artery to the left atrium and left ventricle, pulmonary arterial pressure of 37/13 mmHg and cardiac output of 9.61/minute. Other studies excluded the possibility of sepsis, and high-output cardiac failure was suspected. The patient was discharged in a stable condition and scheduled for AVM embolization management. Unfortunately, she died of a suspected heart attack at home two weeks following discharge.

Cardiac Output↗

[Effect of cordaron on systolic and diastolic functions of the left ventricle in patients with a mixed form of chronic low cardiac output and cardiac arrhythmias].

AIM: To study effects of cordaron on central hemodynamics reflecting systolic and diastolic functions of the left ventricle (LV) in patients with a mixed form of chronic cardiac failure--a systolic dysfunction and LV diastolic dysfunction type I. MATERIAL AND METHODS: 14 patients with a mixed form of chronic heart failure (CHF) and cardiac arrhythmia were followed up for 6 months. All the patients received ACE inhibitors, diuretics, nitrates and, additionally, cordaron in a supporting dose 200-300 mg/day. Control of central hemodynamics was made with echocardiography before, 1, 3 and 6 months of therapy. RESULTS: For 6 months of therapy LV ejection fraction increased by 16%. LV diastolic function improved, primarily, due to a rise of the E max (by 52% for 6 months of therapy). This reflected early diastolic filling of the LV. Improvement of LV diastolic function was associated with heart rate decrease. CONCLUSION: Cordaron used in addition to ACE inhibitors, diuretics, nitrates improves both systolic and diastolic LV function in patients with a mixed form of CHF.

Adult↗

Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor.

OBJECTIVES: 1 To develop a training package for ultrasonic cardiac output monitor (USCOM) cardiac output assessments and determine the number of proctored studies necessary for skill acquisition. 2 To develop criteria for acceptance of cardiac output results obtained with the USCOM. 3 To evaluate the reliability of USCOM cardiac output assessments in the ED. METHODS: The authors developed an audiovisual training package. Four emergency physicians and one geriatrician subsequently underwent hands-on training, and skill acquisition was assessed at the fifth, 10th, 15th and 20th examinations. Six image-scoring criteria were developed to assess acoustic image quality. Upon completion of training a protocol was developed to optimize interassessor reliability. Two trained emergency physicians then performed blinded examinations on ED patients using the protocol and interassessor reliability was evaluated. RESULTS: During training average image score improved between the fifth and 20th assessed patient from 4.6 (95% CI 4.0-5.3) to 5.5 (95% CI 5.0-6.0, Pt-test=0.02) out of 6 and average intra-assessor cardiac output difference improved from 17% (95% CI 4-25) to 5% (95% CI 0-11, Pt-test=0.02). Analysis of 52 cardiac output assessments in 21 ED patients demonstrated excellent interassessor correlation (r=0.96, 95% CI 0.90-0.98, P<0.001). The average interassessor difference in cardiac output and index was 0.2 L/min (4%, 95% CI 3-6) and 0.1 L/min/m2 (4%, 95% CI 2-6), respectively. CONCLUSION: Emergency physicians with no prior ultrasonographic experience can be trained to obtain reliable cardiac output estimations upon conscious ED patients with the USCOM over the course of 20 patient assessments.

Cardiac Output↗

Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization.

OBJECTIVE: To evaluate the accuracy and precision of an advanced thoracic bioimpedance cardiac output monitor by comparing it with conventional thermodilution. DESIGN: Prospective data collected from 47 patients undergoing routine cardiac catheterization. The new bioimpedance system differs from its predecessors in electrode system configuration, advanced signal processing, use of a modified Kubicek equation, and a reliable estimate of left ventricular ejection time from the time derivative bioimpedance signals. SETTING: A cardiac catheterization laboratory in a university affiliated teaching hospital. PATIENTS: A series of 47 relatively homogenous patients undergoing routine cardiac catheterization for suspected cardiac disease. MEASUREMENTS AND MAIN RESULTS: The data from the first 20 patients was used to determine optimal values for coefficients in the bioimpedance cardiac output equations. The coefficients found were used when the system was tested in the subsequent 27 patients. For the last 27 patients, a total of 80 simultaneous pairs of cardiac output measurements were made by conventional thermodilution and by thoracic bioimpedance. The mean difference between the two methods was -0.31 L/min and the standard deviation of the differences was (0.76 L/min). The correlation coefficient was r2 = .72 (p < .001). CONCLUSIONS: The correlation between conventional thermodilution and thoracic bioimpedance cardiac output estimates was good and the standard deviation of the differences was lower than that reported for commercially available devices. The system can be used in the cardiac catheterization lab for reliable and continuous noninvasive measurement of cardiac output.

Cardiac Catheterization↗

Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution.

This randomised, single-blind, double-control study compared and established prospectively the best transoesophageal echocardiography methods for determining cardiac output in patients after cardiac surgery. Thirty patients undergoing coronary artery bypass grafting were included. Measurements were taken postoperatively, after stabilisation in the intensive care unit. Cardiac output was determined by transoesophageal echocardiography in randomised order through the aortic, mitral, and pulmonary valves, right and left ventricular outflow tracts, transgastric surface areas of the left ventricle and left ventricle two-dimensional volumes (Simpson's rules). 'Eyeball guessing' was done off-line. The best results were transaortic measurements using the triangular shape assumption of valve opening, but some values deviated considerably, and none of these approaches reached the limit of agreement set at 30% when compared to thermodilution. Eyeball guessing was comparable to the best transoesophageal echocardiography measurements. We conclude that transoesophageal echocardiography is an unreliable tool for determination of cardiac output in intensive care after cardiac surgery.

Adult↗

Regional blood flow and oxygen transport in patients with the low cardiac output syndrome after cardiac surgery.

OBJECTIVE: To assess systemic and regional oxygen transport after open heart surgery in patients with the low cardiac output syndrome who are receiving vasoactive drugs and in patients with normal hemodynamics during spontaneous rewarming. DESIGN: Prospective, nonrandomized controlled trial. SETTING: Tertiary care center. PATIENTS: Sixteen patients aged 53.1 +/- 8.4 yrs were studied after coronary artery bypass operations: ten patients with a cardiac index of < 1.75 L/min/m2 and six control patients with a cardiac index of > 1.75 L/min/m2. INTERVENTIONS: The patients with a cardiac index of < 1.75 L/min/m2 received either dobutamine alone (n = 5) or in combination with nitroprusside (n = 5). The control patients with a cardiac index of > 1.75 L/min/m2 did not receive vasoactive treatment. The systemic oxygen consumption was measured by indirect calorimetry and the regional blood flow was measured by primed continuous infusion of indocyanine green. MEASUREMENTS AND MAIN RESULTS: Both splanchnic and femoral blood flows increased (p < .05) in parallel with cardiac output during vasoactive drug therapy. High splanchnic oxygen extraction in patients with low cardiac index and flow-dependent splanchnic oxygen consumption in some patients indicated marginal splanchnic oxygen delivery. In addition, femoral blood flow was low and oxygen consumption changed in parallel with oxygen delivery in patients with the low cardiac output syndrome. CONCLUSIONS: In low cardiac output syndrome after cardiac surgery, splanchnic oxygen delivery was marginal and was maintained at the expense of peripheral oxygen delivery. Dobutamine, both alone and in combination with sodium nitroprusside, improved splanchnic oxygen delivery.

Body Temperature↗

Automated cardiac output measurements by ultrasound are inaccurate at high cardiac outputs.

OBJECTIVE: The sonographic technique of automated cardiac output measurement (ACM) is a promising new method to measure cardiac output and could be of use in a high-risk obstetric unit in the treatment of pre-eclamptic patients. The aim was to determine the accuracy of the ACM method. DESIGN: Comparative study of the sonographic technique of ACM versus cardiac output measured by thermodilution (TD). METHODS: The study included 39 intensive care patients, 21 men, 13 non-pregnant women and five severely pre-eclamptic pregnant patients, with a wide range of cardiac outputs, in whom TD catheters had been inserted for clinical reasons. Two separate experienced observers, blinded to the results obtained with the other method, performed four successive measurements in each patient with either the ACM or TD technique. The averaged cardiac output value per patient and method was used for comparison. RESULTS: Cardiac output was successfully measured with ACM and TD in 85 and 100% of patients, respectively. Mean cardiac output measured by ACM (6.77 +/- 1.90 L/min) was significantly lower than that measured by TD (9.12 +/- 3.06 L/min). Although cardiac output values obtained with ACM were significantly correlated with those measured by TD, the ACM values were consistently lower than TD values in the higher cardiac output range; the relationship was represented by ACM = 0.35 TD + 3.55 L/min (r = 0.57, P < 0.001). The (ACM - TD) difference increased significantly with cardiac output, through a difference in stroke volume, not in heart rate. CONCLUSION: The ACM is not an accurate tool to measure cardiac output in patients with a high cardiac output, including treated pre-eclamptic women.

Adult↗

Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications.

PURPOSE OF REVIEW: To describe recent developments in bioimpedance technique and its application in cardiovascular diseases. Cardiac output determination has been used selectively during recent years because of the need for invasive right heart catheterization. Hence, experience with its application in patients with cardiovascular diseases and especially heart failure is limited. Bioimpedance is a novel noninvasive technique determining changes in instantaneous (during one heartbeat) conductance of a small electrical current transferred through the body. By using different algorithms correcting for various body composition constants, it calculates the change in instantaneous arterial blood volume (that is, stroke volume) and cardiac output. Traditionally, bioimpedance cardiac output is determined using either thoracic or whole body techniques according to the location of the electrodes transmitting and receiving the small electrical current. RECENT FINDINGS: Significant progress was achieved in recent years in cardiac output determination by bioimpedance. Newer algorithms using thoracic and whole body bioimpedance have demonstrated better correlation with invasive cardiac output determination. In a few preliminary studies bioimpedance-determined cardiac output was found useful in the diagnosis, risk stratification, and treatment titration of some cardiovascular conditions. Further, larger prospective studies are required to determine the true independent value of cardiac output measurement by bioimpedance for the evaluation of cardiovascular diseases and especially heart failure. SUMMARY: Recently, significant improvement was achieved in cardiac output measurement by bioimpedance with both newer thoracic and whole body techniques. Preliminary studies imply that this measure may be of value in managing some cardiovascular disorders.

Algorithms↗

Haemodynamic and biological effects of intravenous milrinone in patients with a low cardiac output syndrome following cardiac surgery: multicentre study.

The haemodynamic and biological effects of intravenous milrinone were studied in 24 adult patients with a low cardiac output syndrome following cardiac surgery. The patients received a milrinone bolus of 50 micrograms kg-1 over 10 min followed by a 0.375-0.750 micrograms kg-1 min-1 infusion over 48 h. After the first hour of treatment, an increase in cardiac index, systolic index and left ventricular stroke work index, and a decrease in right and left loading pressures, pulmonary artery pressure, systemic vascular resistance and pulmonary vascular resistance were observed while heart rate and systemic arterial pressure were not modified. These haemodynamic effects were maintained over the 48 h of treatment and persisted 3 h after discontinuation of treatment. Milrinone, which possesses inotropic and vasodilatory effects, increased cardiac performance and corrected the low cardiac output in all patients.

Adult↗

Pituitary-gonadal dysfunction in low-output cardiac failure.

Diminished cardiac output and digoxin therapy appear to have opposing effects on testosterone, oestradiol and luteinizing hormone concentrations. Depression of the levels of these hormones was significantly correlated with a decrease in cardiac index and elevation was noted by digoxin therapy of long duration. The effect of cardiac output is most marked on testosterone and that of digoxin on oestradiol.

Adult↗

Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique.

BACKGROUND: Assessment of cardiac output (CO) by the indocyanine green (ICG) dye dilution technique (IDD) with transcutaneous signal detection may be a less invasive alternative to the pulmonary artery catheter (PAC). The aim of this study was to determine the accuracy and reliability of the DDG2001 analyzer (Nihon Kohden Corp, Tokyo, Japan) using a finger (IDDf) and a nose (IDDn) sensor as compared with the thermodilution technique by PAC. METHODS: In 31 consecutive patients after routine cardiac surgery, CO measurements were performed by IDD compared with the thermodilution technique following postoperative haemodynamic stabilization in the intensive care unit. Repeated measurements were made at 30-min intervals. CO was determined by iced water bolus (IWB: mean of three repeated injections) and IDDf or IDDn, respectively (mean of three repeated ICG injections). RESULTS: Thirty-three per cent of all measurements for IDDf and 9% for IDDn failed due to a missing signal detection. Mean bias for IDDf to IWB was -0.5 l min(-1).m(-2) (limits of agreement: -1.8/0.8 l min(-1).m(-2)) and for IDDn to IWB was -0.1 l min(-1).m(-2) (limits of agreement: -1.6/1.5 l min(-1).m(-2)). Correlation between IDDf and IWB (r = 0.2) was found to be inferior to the correlation between IDDn and IWB (r = 0.5). CONCLUSION: The IDD showed a systematic bias compared with the IWB and its performance was limited due to signal detection failure. Therefore, the DDG2001 analyzer cannot be recommended as a substitute for the PAC in routine monitoring of cardiac output after cardiac surgery.

Cardiac Output↗