Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Blood Specimen Collection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

[Contribution to the morphology and biochemistry of mustelide blood. 1. Blood specimen collection in various mustelides with special reference to the use of the tissue adhesive "Fimomed"].

An account is given of various techniques of blood sampling in the context of certain mustelids, including cardiopuncture, amputation of tail tip, talon cutting, incision of the ear vein, puncture of the jugular or femoral vein, and catheterisation of the abdominal aorta. Reference is made to details of use of all techniques, characteristics, advantages and potential setbacks, and preferable use of some of the tested methods to collect blood from mustela and martes species. Blood collection from the abdominal aorta may be helpful in obtaining no-haemolysis and no-additive plasma for biochemical multi-screening. Biochemical, pharmacological, and toxicological follow-up checks may be feasible under certain conditions following surgical exposure of the external jugular vein. The use of "Fimomed" (n-butylcyano-acrylate), a tissue adhesive, may help to reduce effort in terms of time and material and consequently, rationalise veterinary hygiene action as a whole, provided that the conditions for its application are observed. The skin adhesive is properly applicable to skin lesions of mustelids. A combination of suturing with adhesive should be used to close laparotomy wounds for better mechanical strength of the abdominal wall. Possible applications of "Fimomed" should be tested with other species as well.

Animals↗

[Use of filter paper for blood specimen collection in poultry for use in the detection of antibodies to Newcastle disease virus].

Trials were conducted to verify the possibility of poultry blood sampling with filter papers for subsequent examination of the eluates for the presence (and level) of haemagglutination-inhibition antibodies against the Newcastle disease virus (NDV). Qualitative examination was performed in 294 paired samples of sera and eluates, representing 10 selective sets, coming from three vaccinated poultry flocks. The numbers of positive sera (dilution ratios 1:20 and higher) and positive eluates of filter papers (dilution ratios of 1: 2 and higher) were compared and it was found that there were 238 positive paired samples (81%) and 30 were negative (10.2%), hence, there were like reactions in 268 paired samples (91.2% of the total number of samples examined). It was only in 25 paired samples that positivity was recorded just in the sera: 22 times with a titre of 1:20 and three times with a titre of 1:40. In one case, positivity was recorded just in the eluate. The final titres were compared in 181 paired samples of sera and eluates, all diluted at a ratio of 1:2, and it was found that the concentration of the haemagglutination-inhibition antibodies in the eluates corresponded to serum dilution ratio of 1:20. Under this assumption, the antibodies were found to have the same titre in 164 paired samples (55.8%) during the quantitative evaluation. A lower titre was recorded in 82 eluate samples (27.9%) and a higher antibody titre in 48 eluate samples (16.3%) (in comparison with the antibody titres in the respective sera). The over-all average geometrical titre (GMT) of antibodies was 1:65 in the eluates and 1:75 in the sera.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Use of blood specimens collected on filter paper in screening for abnormal hemoglobins.

Both cellulose acetate electrophoresis and citrate agar electrophoresis were performed on 834 blood samples collected on filter paper in Jamaica and shipped for testing to the National Hemoglobinopathy Standardization Laboratory at the U.S. National Center for Disease Control. Additionally, 30 blood samples collected locally were stored on filter paper, in microhematocrit capillary tubes, and as whole blood specimens; at selected times the samples were tested for stability to determine the best sample-collection technique for hemoglobin electrophoresis. Results were most nearly accurate when both cellulose acetate electrophoresis and citrate agar testing were used. The methods are easy to perform, but results are unreliable if the blood samples on filter paper are stored at 4 degrees C for longer than two weeks before they are tested.

Agar↗

Electrospray tandem mass spectrometry for analysis of acylcarnitines in dried postmortem blood specimens collected at autopsy from infants with unexplained cause of death.

BACKGROUND: Deaths from inherited metabolic disorders may remain undiagnosed after postmortem examination and may be classified as sudden infant death syndrome. Tandem mass spectrometry (MS/MS) may reveal disorders of fatty acid oxidation in deaths of previously unknown cause. METHODS: We obtained filter-paper blood from 7058 infants from United States and Canadian Medical Examiners. Acylcarnitine and amino acid profiles were obtained by MS/MS. Specialized interpretation was used to evaluate profiles for disorders of fatty acid, organic acid, and amino acid metabolism. The analyses of postmortem blood specimens were compared with the analyses of bile specimens, newborn blood specimens, and specimens obtained from older infants at risk for metabolic disorders. RESULTS: Results on 66 specimens suggested diagnoses of metabolic disorders. The most frequently detected disorders were medium-chain and very-long-chain acyl-CoA dehydrogenase deficiencies (23 and 9 cases, respectively), glutaric acidemia type I and II deficiencies (3 and 8 cases, respectively), carnitine palmitoyl transferase type II/translocase deficiencies (6 cases), severe carnitine deficiency (4 cases), isovaleric acidemia/2-methylbutyryl-CoA dehydrogenase deficiencies (4 cases), and long-chain hydroxyacyl-CoA dehydrogenase/trifunctional protein deficiencies (4 cases). CONCLUSIONS: Postmortem metabolic screening can explain deaths in infants and children and provide estimates of the number of infant deaths attributable to inborn errors of metabolism. MS/MS is cost-effective for analysis of postmortem specimens and should be considered for routine use by Medical Examiners and pathologists in unexpected/unknown infant and child death.

Autopsy↗

[Blood specimen collection and liver biopsy in miniature swine].

The collection of investigational material means a problem occasionally during long-term observations of experimental animals. The described methods for punction of the superior vena cava and the percutaneous liver biopsy by means of a prostatic biopsy needle in miniature swine are carried out easily by one examinator without auxiliary personnel. Sufficient investigational material of good quality is to receive. Complicating factors are shown.

Animals↗

Comparison of hemolysis in blood samples collected using an automatic incision device and a manual lance.

OBJECTIVE: To evaluate the magnitude of hemolysis in blood specimens collected from the heels of newborns using an automated blood collection device that uses a spring-loaded lance with blood collected using a manual lance. DESIGN: A randomized controlled trial involving 134 newborns assigned to have blood collected using either an automated blood collection device or a manual lance. A single experienced individual performed all blood collections. Serum hemoglobin concentrations were measured in all samples to gauge the extent of hemolysis. SETTING: A neonatology unit in a 740-bed tertiary care teaching hospital. PATIENTS: Healthy newborns with gestational ages ranging from 33 weeks to 41 weeks. Blood samples were collected from study participants at between 7 and 126 hours postpartum. Group 1 consisted of 66 individuals who had blood collected using the manual lance. Group 2 contained 68 individuals with blood collected using a spring-loaded automatic lance. MAIN OUTCOME MEASURE: Plasma hemoglobin content as an indicator of the extent of hemolysis. RESULTS: There were no significant differences between newborns in groups 1 and 2 with respect to gestational age, birth weight, or time interval between birth and time of blood collection. We found a highly significant difference with respect to plasma hemoglobin concentrations in specimens collected with an automated lance (hemoglobin, 2.35 g/L) vs that collected using the hand-held lance (hemoglobin, 4.85 g/L). CONCLUSION: Use of an automated spring-loaded lance allows for the collection of blood specimens with smaller levels of plasma hemoglobin.

Birth Weight↗

[The leukocyte count is a valuable parameter for detecting classical swine fever].

In this paper we describe a study of the use of the white blood cell count (wbcc) as a parameter for detecting outbreaks of Classical Swine Fever (CSF). Meta-analysis of the results of challenge experiments revealed that oronasal infection of SPF-pigs with the virulent CSF virus (CSFV) strains Brescia or NL9201 resulted in a significant decrease in the average white blood cell count during the first week after inoculation of the virus. Challenge of conventional finishing pigs and sows with the moderately virulent strain Paderborn also resulted in a significant decrease in the average wbcc. However, this decrease was not observed after inoculation of SPF pigs with the mildly virulent CSFV strains Henken, Zoelen, or Bergen. The usefulness of clinical inspection in combination with wbcc to detect CSF outbreaks in the field was examined using the results of 214 EDTA blood specimens collected from 22 infected herds and 7250 EDTA blood specimens collected from 1450 non-infected herds. Half of the infected herds had been infected with the moderately virulent CSFV strain Venhorst (closely related to strain Paderborn) during the 1997-98 epidemic in the Netherlands. The other half had been infected with the moderately virulent CSFV strain Loraine. Using these data as a starting point, 1000 samples of one to ten specimens were generated by Monte Carlo simulation. These simulated samples and the samples of the non-infected herds were analysed by use of Receiver Operating Characteristic curves. On the basis of that analysis, the optimal number of animals whose wbcc needed to be determined to detect a CSF outbreak was five. With this number of animals, in conjunction with the threshold of 8000 white blood cells per mm3 (meaning that a herd is designated as CSF suspect if one or more of the five specimens has a white blood cell count of 8000 leukocytes/mm3 or less), the test procedure had a herd sensitivity (HSE) of 94.5% and a herd specificity (HSP) of 97.2%). The HSE is defined as the percentage of samples of infected herds with a positive result of the test procedure; HSP is defined as the percentage of uninfected herds with a negative result of the test procedure. We conclude that the wbcc can help the veterinary practitioner to detect outbreaks of CSF caused by (moderately) virulent CSFV strains. However, for the detection of outbreaks caused by mildly virulent CSFV strains, the contribution of the wbcc is doubtful. Development of additional tools that can improve the clinical diagnosis of the veterinary practitioner remains desirable.

Animals↗

Prevalence of substance abuse among patients with physical diseases seen in an emergency room in Japan.

According to a nationwide general population survey on drug use in Japan, the lifetime prevalence of methamphetamine is low when compared to the United States. To confirm the hypothesis of a lower point prevalence of methamphetamine in an emergency room (ER) in Japan than in the United States, we collected blood specimens from an urban area of heavy methamphetamine prevalence in Tokyo, Japan, and analyzed the sera using REMEDi-HS based on an unlinked anonymity. Twenty kinds of drugs other than psychotropics were detected in 55 of 279 subjects (19.7%). Nineteen kinds of psychotropics were detected in twenty (7.2%) subjects. Psychotropics were detected in eleven patients with physical diseases and no acute intoxication. Methamphetamines were detected in three subjects (1.09%, 95% confidence interval 1.073-1.088) and in one of 46 subjects with injury (2.2%). It is necessary to look at the methodological differences between this study and previous studies; however, this finding supports the lower point prevalence of methamphetamine in an ER in Japan than in an ER in the United States.

Amphetamine-Related Disorders↗