Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Air transport of patients with intracranial air: computer model of pressure effects.

INTRODUCTION: Air is commonly trapped within the skull in patients who have been treated for trauma or intracranial hemorrhage. In Sweden, when such a patient is transported by air ambulance it is standard procedure to maintain sea-level pressure in the cabin to prevent increased intracranial pressure (ICP). However, this type of flight operation is more difficult and expensive. Maintenance of sea-level cabin pressure is not common practice all over the world, and the criteria supporting the choice of pressurization during transport are inadequate and in need of evaluation. The purpose of this study was to develop and evaluate a model to simulate the influence of intracranial air on ICP during air transport. METHODS: We identified an existing nonlinear model of the cerebral spinal fluid and intracranial pressure dynamics, then added intracranial air as a new component and evaluated the model through simulations. RESULTS: The model behaved as expected, and the simulations indicated that under normal flying conditions with decreased cabin pressure the initial intracranial air volume will increase by approximately 30% at normal maximum cabin altitude, 8000 ft. The increase in ICP depends upon both the initial air volume and the rate of change in cabin altitude. For an intracranial air volume of 30 ml the estimated worst-case increments of ICP from sea level to maximum altitude would be from 10 mm Hg to 21.0 mm Hg, or from 20 mm Hg to 31.8 mm Hg. DISCUSSION: Our results support the need for maintenance of sea-level pressure during air transport of patients with suspected intracranial air, since an ICP increment could potentially impair the patient's clinical condition.

Air Ambulances↗

Identification of the epidural space: is loss of resistance to air a safe technique? A review of the complications related to the use of air.

BACKGROUND AND OBJECTIVES: The major determinant of successful epidural anesthesia is the localization of the epidural space. The manual loss of resistance technique is widely used by anesthesiologists in identifying the epidural space. Should air or saline be used in detecting the point of loss of resistance? No consensus exists as to which technique is superior, and individual providers currently use the technique with which they are most comfortable. The incidence of adverse effects associated with the use of epidural air is unknown and may be underreported as the effects may be unrecognized or considered trivial. The authors comprehensively review the complications of epidural air from published reports. METHODS: Using the appropriate key words, the authors searched the Medline (National Library of Congress) scientific data bank from 1966 to 1995, for case reports of epidural complications. RESULTS: There are few prospective, controlled, double-blinded studies comparing the relative merits of using air versus saline for the loss of resistance technique of epidural placement. There are, however, numerous case reports. Complications associated with the use of air for the loss of resistance technique included pneumocephalus, spinal cord and nerve root compression, retroperitoneal air, subcutaneous emphysema, and venous air embolism. Additionally, inadequate analgesia and paresthesia have been associated with the loss of resistance technique using air. Transient and permanent neurologic sequelae have been attributed to some of the complications. The simultaneous administration of nitrous oxide and positive. Pressure ventilation has also been reported to expand localized collections of air, resulting in heightened symptoms. CONCLUSIONS: The potential complications associated with the use of air for identifying the epidural space with the loss of resistance technique may outweigh the benefits. The use of saline to identify the epidural space may help to reduce the incidence of these complications.

Adult↗

Role of the autoimmune regulator (AIRE) gene in alopecia areata: strong association of a potentially functional AIRE polymorphism with alopecia universalis.

Alopecia areata is characterized by a reversible form of patchy or complete hair loss associated with T-cell infiltration of hair follicles. The lifetime disease risk of approximately 1.4% in the general population is increased to more than 30% in autoimmune polyendocrinopathy candidiasis ectodermal dysplasia syndrome (APECED), a recessive condition resulting from a mutation of the autoimmune regulator (AIRE) gene on chromosome 21q22.3. Aire protein is thought to have transcriptional regulatory activity but its role is not well defined at present. In this study, we have examined the possible involvement of AIRE in the pathogenesis of alopecia areata. On screening the AIRE coding sequence, we identified 20 variants. Two of these at positions, G961C and T1029C, give rise to amino acid changes, S278R and V301A, located in the DNA-binding segment (SAND) and PHD1 zinc finger motif, respectively. We found no difference in the frequency of the AIRE T1029C polymorphism between the control and patient groups. We genotyped 202 alopecia areata patients and 175 matched Caucasian controls for the AIRE G961C alleles. The frequency of the rare allele (961G) was 0.08 in the controls and there was a significant increase to 0.13 in alopecia areata overall and 0.20 in severe disease (alopecia universalis). We found no association between the AIRE G961G variant and mild (patchy) alopecia areata or alopecia totalis. However, the AIRE 961G allele is a potent risk factor (> 3) for the severest form of alopecia areata, and for disease of early age at onset (at 30 years). The change from serine to arginine in the SAND domain of AIRE protein may have a significant effect on AIRE DNA-binding activity. Moreover, our results could provide a rational explanation of the unusually high frequency of AA in APECED patients, supporting the concept of AA as an autoimmune disease.

Adolescent↗

Comparative study of influence on tensile bond strength of a composite to dentin using Er:YAG laser, air abrasion, or air turbine for preparation of cavities.

OBJECTIVES: The purpose of this study was to evaluate, in vitro, the tensile bond strength of the Single Bond (3M) adhesive system placed over dentin surfaces treated with air turbine, Er:YAG laser without contact and in focused or air abrasion. SUMMARY BACKGROUND DATA: The use of dentin adhesives is a well-established clinical routine among the dentists. However, there have been few reports comparing the influence of the Er:YAG laser, air abrasion, and air turbine on the Single Bond tensile bond strength of adhesives systems to dentin fact that could influence which tools dentists select for use in cavity preparations. METHODS: Twenty-three extracted retained human molars were used in this study. The coronal portion was divided in two parts and fixed in acrylic resin; the occlusal surface was abraded to a 2-mm width with a mechanic lathe until the dentin surface was completely exposed. The dental portions were divided into three groups of 15 each and treated with Er:YAG laser, air abrasion, or air turbine. A 3 mm hole in the center of each tooth was marked off using contact paper. Single Bond (3M) adhesive system was applied after acid phosphoric at 35% application for 15 sec over dentin surfaces. A resin composite cone was built into the delimited area to accomplish the tensile bond strength test on the EMIC universal test machine. The specimens were then evaluated by stereoscopy to determine the type of failures into the dentin-adhesive-resin composite surface. RESULTS: The tensile test was performed using the universal testing machine EMIC DL-2000 at a cross-head speed of 0.5 mm/min. The average results were: air turbine (17.52 MPa), Er:YAG laser (16.65 MPa) and air abrasion (15.83 MPa). Statistical treatment by ANOVA and Tukey's test (p < 0.01) showed no significant differences between the groups tested. The tensile bond strength test to the dentin showed no significant difference among the three groups when the Single Bond was used after the 35% phosphoric-acid conditioning. The stereoscopy showed a predominant adhesive failure in all groups. CONCLUSION: These results suggest that Single Bond tensile bond strength is the same as dentin prepared by Er:YAG laser, air abrasion, or air turbine.

Air Abrasion, Dental↗

Quantification and control of the spatiotemporal gradients of air speed and air temperature in an incubator.

Around the optimal incubator air temperature only small spatiotemporal deviations are allowed. However, air speed and air temperature are not uniformly distributed in the total volume of the incubator due to obstruction of the eggs and egg trays. The objectives of this research were (1) to quantify the spatiotemporal gradients in temperature and velocity and (2) to develop and validate a control algorithm to increase the uniformity in temperature during the entire incubation process. To improve the uniformity of air temperature, the airflow pattern and the air quality need to be controlled more optimally. These data show that the air temperature between the eggs at a certain position in a large incubator is the result of (1) the mean air temperature of the incubator; (2) the exchange of heat between the egg and its micro-environment, which is affected by the air speed at that certain position; (3) the time-variable heat production of the embryo; and (4) the heat influx or efflux as a result from the movement of hot or cold air in the incubator toward that position, which is affected by the airflow pattern. This implies that the airflow pattern needs to be controlled in a more optimal way. To maximize the uniformity of air temperature, an active and adaptive control of the three-dimensional (3-D) airflow pattern has been developed and tested. It was found to improve the spatiotemporal temperature distribution. The chance of having a temperature reading in the interval from 37.5 to 38.1 degrees C increased by 3% compared to normal operating conditions.

Air Movements↗

[Invention of an air forced ventilated micro-isolation cage and rack system--environment within the cages: ventilation, air flow].

A forced air ventilation system for small laboratory animals was developed. The system consists of an air handling unit with air supply and exhaust fans, a rack, hard cage covers with a large diameter air inlet and an outlet, and shoe box cages. Air flow from the supply duct, to the exhaust duct and within the cage were observed. Variations in air flow among cages was minimal. The optimal air exchange rate of the cages in this system was determined to be 60 times per hour based on the results obtained in the present study. At this air exchange rate, air flow at the base of the cages had a velocity of less than 0.09m/sec, which was within the range of recommended values for humans. The observed results show that the system developed is capable of sustaining a laboratory animal microenvironment well in terms of air flow, without too much energy cost.

Air Movements↗

Particulate air pollution and nonfatal cardiac events. Part II. Association of air pollution with confirmed arrhythmias recorded by implanted defibrillators.

Implanted cardioverter defibrillators (ICDs) monitor patients for episodes of cardiac arrhythmias and can initiate a therapeutic intervention to restore normal heart rhythm. These devices also record dates, times, and electrograms of these episodes. We examined the effects of air pollution on the incidence of arrhythmias in 195 cardiac patients with ICD devices in the Boston metropolitan area between July 1995 and July 2002. Gaseous air pollutant and meteorologic data were measured on essentially all days, fine particle mass on 80% of the days, and black carbon (BC) on 61% of the days. Date and time of detected arrhythmias, intracardiac electrograms, and therapeutic interventions were downloaded during the patients' regular follow-up visits every 3 months on average. A cardiac electrophysiologist reviewed electrograms recorded before, during, and after the arrhythmias and categorized them into ventricular and supraventricular events. Risk of arrhythmias associated with air pollution was estimated using logistic regression with adjustments for season, temperature, relative humidity, day of the week, and patient. We found increased relative risks of ventricular arrhythmias (VAs) associated with an increase in 2-day mean concentrations for all air pollutants considered, although these associations were not statistically significant. The relative risks of supraventricular arrhythmias (SVAs) increased in association with 2-day mean concentrations for all air pollutants, and this association was significant only for sulfur dioxide (SO2) at 4 ppb (odds ratio [OR] = 1.33; 95% confidence interval [CI] = 1.04, 1.70). The positive associations of VAs and SVAs with particulate matter less than 2.5microm in aerodynamic diameter (PM2.5; also referred to as fine particles), carbon monoxide (CO), nitrogen dioxide (NO2), BC, and SO2 suggest a link with motor vehicle pollutants. We explored patient characteristics that may have identified subjects susceptible to the effects of air pollution. The association of air pollution with SVAs was blunted by regularly prescribed beta-blockers. We found stronger associations of air pollution with VAs for episodes within 3 days of a previous arrhythmia, suggesting that VAs were triggered by air pollution episodes in combination with other factors that raised the patient's underlying risk. Although ICDs are specifically designed to monitor and treat only VAs, these results suggest that air pollution may trigger both VAs and SVAs.

Adult↗

Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry (< 80% R. H.) and warm (> 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

Air Conditioning↗

Full body forced air warming: commercial blanket vs air delivery beneath bed sheets.

PURPOSE: Single-use commercial forced air warming blankets serve only to distribute heated air from a blower. Standard bed sheets may be equally effective in delivering hot air within a lower body field and at lower cost. METHODS: Heated forced air at 38 degrees and 43 degrees was delivered within a simulated full-body field beneath standard hospital bed sheets or via a BAIR Model 315 commercial blanket. The air temperatures maintained within, as well as the caloric uptake of standard bodies containing 1000 ml water, were studied under standard simulated operating room conditions. Thermal input was provided by one Bair Hugger Model 500 Warming Unit and hospital acquisition cost for materials were calculated. RESULTS: Air temperatures measured within the full body field at the three test sites were as great or greater using bed sheets (33.4-35.8 degrees) as with the commercial blanket (31.1-33.9 degrees), in spite of the 5 degrees cooler outlet temperature air settings @ 38 degrees vs 43 degrees, respectively (P = 0.003). Forced air delivered beneath bed sheets heated standardized thermal bodies twice as effectively as commercial blankets using identically warmed (38 degrees) forced air and heated as well as, or better, at the 38 degrees setting than did the commercial blanket at the 43 degrees setting. Calculated acquisition costs for sheets vs commercial blankets were $0.76 vs $18.00 US, respectively. CONCLUSION: The simplicity, efficacy and economy of containing 38 degrees warm air beneath bed-sheets offer several advantages over commercial blankets and warrant further study.

Bedding and Linens↗

An objective definition of air mass types affecting Athens, Greece; the corresponding atmospheric pressure patterns and air pollution levels.

This work aims at defining characteristic air mass types that dominate in the region of Athens, Greece during the cold (November-March) and the warm (May-September) period of the year and also at evaluating the corresponding concentration levels of the main air pollutants. For each air mass type, the mean atmospheric pressure distribution (composite maps) over Europe and the Mediterranean is estimated in order to reveal the association of atmospheric circulation with air pollution levels in Athens. The data basis for this work consists of daily values of thirteen meteorological and six pollutant parameters covering the period 1993-97. The definition of the characteristic air mass types is attempted objectively by using the methods of Factor Analysis and Cluster Analysis. The results show that during the cold period of the year there are six prevailing air mass types (at least 3% of the total number of days) and six infrequent ones. The examination of the corresponding air pollution concentration levels shows that the primary air pollutants appear with increased concentrations when light or southerly winds prevail. This is usually the case when a high pressure system is located over the central Mediterranean or a low pressure system lays over south Italy, respectively. Low levels of the primary pollutants are recorded under northeasterly winds, mainly caused by a high pressure system over Ukraine. During the warm period of the year, the southwestern Asia thermal low and the subtropical anticyclone of the Atlantic Ocean affect Greece. Though these synoptic systems cause almost stagnant conditions, four main air mass types are dominant and ten others, associated with extreme weather, are infrequent. Despite the large amounts of total solar radiation characterizing this period, ozone concentrations remain at low levels in central Athens because of its destruction by nitric oxide.

Air Movements↗

Epidemiologic evidence for asthma and exposure to air toxics: linkages between occupational, indoor, and community air pollution research.

Outdoor ambient air pollutant exposures in communities are relevant to the acute exacerbation and possibly the onset of asthma. However, the complexity of pollutant mixtures and etiologic heterogeneity of asthma has made it difficult to identify causal components in those mixtures. Occupational exposures associated with asthma may yield clues to causal components in ambient air pollution because such exposures are often identifiable as single-chemical agents (e.g., metal compounds). However, translating occupational to community exposure-response relationships is limited. Of the air toxics found to cause occupational asthma, only formaldehyde has been frequently investigated in epidemiologic studies of allergic respiratory responses to indoor air, where general consistency can be shown despite lower ambient exposures. The specific volatile organic compounds (VOCs) identified in association with occupational asthma are generally not the same as those in studies showing respiratory effects of VOC mixtures on nonoccupational adult and pediatric asthma. In addition, experimental evidence indicates that airborne polycyclic aromatic hydrocarbon (PAH) exposures linked to diesel exhaust particles (DEPs) have proinflammatory effects on airways, but there is insufficient supporting evidence from the occupational literature of effects of DEPs on asthma or lung function. In contrast, nonoccupational epidemiologic studies have frequently shown associations between allergic responses or asthma with exposures to ambient air pollutant mixtures with PAH components, including black smoke, high home or school traffic density (particularly truck traffic), and environmental tobacco smoke. Other particle-phase and gaseous co-pollutants are likely causal in these associations as well. Epidemiologic research on the relationship of both asthma onset and exacerbation to air pollution is needed to disentangle effects of air toxics from monitored criteria air pollutants such as particle mass. Community studies should focus on air toxics expected to have adverse respiratory effects based on biological mechanisms, particularly irritant and immunological pathways to asthma onset and exacerbation.

Air Pollutants↗

Clearing the air: a model for investigating indoor air quality in Texas schools.

This pilot project focused on the assessment of indoor air quality at a local high school in Galveston, Texas, using methods based on guidelines for the U.S. Environmental Protection Agency's Indoor Air Quality Tools for Schools program. Tools for Schools, developed for evaluating and ensuring acceptable air quality for schools, takes a low-cost, minimal-involvement, primarily educational approach. The authors also compared the findings from this approach with the results of an air-sampling program. The overall goal was to determine if use of Tools for Schools was sufficient to identify conditions with the potential to cause adverse health effects. The primary objectives were to 1) establish an indoor air quality committee for the school to implement Tools for Schools assessments and management strategies, 2) collect air quality data in high-risk areas identified within the school by the indoor air quality committee, 3) collect outdoor air quality data at or in close proximity to the school, and 4) develop methods and instruments for assessing environmental risks associated with daily school attendance. Data were gathered on levels of formaldehyde and other volatile organic compounds (VOCs), ozone, particulate matter (PM10), mold, relative humidity, and temperature. Data values for each sampled pollutant were compared with federal standards, recommended values established by the American Conference of Governmental Industrial Hygienists for non-industrial populations, and effects screening levels developed by the Texas Commission on Environmental Quality. Levels of all VOCs except formaldehyde were found to be well within guidelines, as were ozone and particulate-matter levels. Mold, however, was widespread, including both common species and species associated with allergy and asthma, such as Aspergillus and Alternaria. In general, Tools for Schools provides an excellent foundation for a school indoor air quality program, although the authors did find it necessary to streamline data collection and did find that mold with the potential for adverse health effects was present, albeit not visible in some areas.

Air Pollutants↗

Effect of dry-cleaned clothes on tetrachloroethylene levels in indoor air, personal air, and breath for residents of several New Jersey homes.

Several volatile organic compounds, including tetrachloroethylene, have been found to be nearly ubiquitous in residential indoor environments during previous TEAM studies. Eleven homes in New Jersey were monitored over three or five days to examine the effect of bringing freshly dry-cleaned clothes into the home on indoor air levels and personal exposures to tetrachloroethylene. Indoor air, personal air, and breath concentrations were measured over multiple 12-hrs periods before and after dry-cleaned clothes were introduced into nine of the homes. No dry-cleaned clothes were introduced into the two remaining homes. Outdoor air tetrachloroethylene concentrations were measured at six of the eleven homes. Indoor/outdoor concentration ratios and source strengths were calculated at the six homes with outdoor measurements. Elevated indoor air levels and human exposures to tetrachloroethylene were measured at seven of the nine homes with dry-cleaned clothes. Indoor air concentrations reached 300 micrograms/m3 in one home and elevated indoor levels persisted for at least 48 hrs in all seven homes. Indoor/outdoor tetrachloroethylene concentration ratios exceeded 100 for the four homes with both dry-cleaned clothes and outdoor measurements. Maximum source strengths ranged from 16 to 69 mg/hr in these homes and did not directly correspond to the number of dry-cleaned garments brought into the home. Breath levels of tetrachloroethylene increased two to six-fold for participants living in seven homes with increased indoor air levels. Indoor air, personal air, and breath tetrachloroethylene concentrations were significantly related (0.05 level) to the number of garments introduced divided by the home volume.

Air Pollutants↗

Local air quality management as a risk management process: assessing, managing and remediating the risk of exceeding an air quality objective in Great Britain.

Air quality is managed in Great Britain via an effects-based, risk management process designed to provide a dynamic solution to public health issues associated with elevated concentrations of seven specified air pollutants. This paper is concerned with an examination and evaluation of the process of Local Air Quality Management (LAQM) in Great Britain from the late 1980s to date as a risk management process. The statutory basis of LAQM process is provided by the Environment Act 1995. The Act provides a framework in which national and local actions are required to identify and remediate areas of poor air quality. Within this framework, the implementation of the process at national and local levels is considered, leading to an identification and assessment of risks in the formulation and implementation of air quality management policy and practice. Local Authorities began the process of Review and Assessment in 1999 and the first round of the process concluded in 2001. Following this, some 129 Local Authorities declared one or more Air Quality Management Areas (AQMAs). The Review and Assessment elements of the framework were subjected to an evaluation in 2001 and the essential elements of it were confirmed as fit for purpose. The evaluation led to a confirmation of the process of LAQM but also a simplification based on the experience of Round 1. Now, a two step process is required comprising of an Updating and Screening Assessment and, where a risk of exceeding an Air Quality Objective (AQO) is identified, a Detailed Assessment follows. The Government has identified a time scale for Review and Assessment through to 2010 and also introduced the requirement of a regular Progress Report in order that a Local Authority is able to address routine matters of air quality management. The risks inherent in epidemiological or scientific uncertainty are factored into the LAQM process at an early stage of the process and, by identifying the risks and subjecting them to regular review, the process provides a 'level playing field' across spatial and temporal scales. Whilst the process of LAQM described in this paper has been developed for Great Britain, the generic elements of the process are applicable to other countries challenged by air pollution problems which require both national and local action to resolve them.

Air Pollution↗

Interactions between particulate air pollution and temperature in air pollution mortality time series studies.

In many community time series studies on the effect of particulate air pollution on mortality, particulate air pollution is modeled additively. In this study, we investigated the interaction between daily particulate air pollution and daily mean temperature in Cook County, Illinois and Allegheny County, Pennsylvania, using data for the period 1987-1994. This was done through the use of joint particulate air pollution-temperature response surfaces and by stratifying the effect of particulate air pollution on mortality by temperature. Evidence that the effect of particulate air pollution on mortality may depend on temperature is found. However, the results were sensitive to the number of degrees of freedom used in the confounder adjustments, the particulate air pollution exposure measure, and how the effects of temperature on mortality are modeled. The results were less sensitive to the estimation method used--generalized linear models and natural cubic splines or generalized additive models and smoothing splines. The results of this study suggest that in community particulate air pollution mortality time series studies the possibility of an interaction between daily particulate air pollution and daily mean temperature should be considered.

Aged↗

Automobile air bags: friend or foe? A case of air bag-associated ocular trauma and a related literature review.

BACKGROUND: Although air bags are placed in automobiles to act as safety devices, they have been shown to carry a risk of injury themselves. Ocular injury, in particular, can often be a direct consequence of air bag deployment. A case of ocular air bag injury is presented. A discussion and review of the current literature on this issue follows. CASE REPORT: A 63-year-old man was transferred to our clinic after sustaining injuries related to a motor vehicle accident, during which the automobile's air bag was deployed. Initial examination revealed many signs of blunt ocular trauma of the O.D., including iridodialysis, dislocated lens with traumatic cataract, and traumatic/inflammatory glaucoma. Initial B-scan showed an attached retina O.D. One month later, the patient underwent an attempted pars plana vitrectomy with lensectomy, iris repair, and insertion of an anterior chamber intraocular lens. Complications arose during the procedure, and a total retinal detachment developed. Resultant acuity is no light perception O.D. CONCLUSIONS: Although ocular morbidity can be a direct consequence of air bag deployment, most eye injuries are minimal, and seem to be outweighed by the benefits of air bags. Drivers, as well as passengers, can minimize associated injuries by adhering to specific safety guidelines. This, as well as continual modification and improvement in air bag design, will maximize the safety of air bags and decrease the incidence of vision-threatening ocular injury caused by air bag deployment.

Accidents, Traffic↗

Large scale air monitoring: lichen vs. air particulate matter analysis.

Biological indicator organisms have been widely used for monitoring and banking purposes for many years. Although the complexity of the interactions between organisms and their environment is generally not easily comprehensible, environmental quality assessment using the bioindicator approach offers some convincing advantages compared to direct analysis of soil, water, or air. Measurement of air particulates is restricted to experienced laboratories with access to expensive sampling equipment. Additionally, the amount of material collected generally is just enough for one determination per sampling and no multidimensional characterization might be possible. Further, fluctuations in air masses have a pronounced effect on the results from air filter sampling. Combining the integrating property of bioindicators with the world wide availability and particular matrix characteristics of air particulate matter as a prerequisite for global monitoring of air pollution is discussed. A new approach for sampling urban dust using large volume filtering devices installed in air conditioners of large hotel buildings is assessed. A first experiment was initiated to collect air particulates (300-500 g each) from a number of hotels during a period of 3-4 months by successive vacuum cleaning of used inlet filters from high volume air conditioning installations reflecting average concentrations per 3 months in different large cities. This approach is expected to be upgraded and applied for global monitoring. Highly positive correlated elements were found in lichens such as K/S, Zn/P, the rare earth elements (REE) and a significant negative correlation between Hg and Cu was observed in these samples. The ratio of concentrations of elements in dust and Usnea spp. is highest for Cz, Zn and Fe (400-200) and lowest for elements such as Ca, Rb, and Sr (20-10).

Air Pollution, Indoor↗

Air distribution during in situ air sparging: an overview of mathematical modeling.

The performance of in situ air sparging is controlled by the distribution of air pathways in the subsurface, which is in turn controlled by the structure of the medium to be sparged. The specific pathways that the air follows are determined, at the grain scale, by the distribution of air entry pressures of the pores. At the field scale, pore size distributions are usually correlated with heterogeneous structures (e.g. layers) within the medium, which control the macroscopic distribution of the air. The processes that produce an observed air distribution at a particular site are complicated, and are potentially well suited to modeling with multiphase flow models. Recent numerical modeling of heterogeneous media appears to successfully represent expected distributions of air; however, current models do not provide a tool to predict sparging performance. For this to be the case, the models need to represent the detailed structure of the medium at the site to be studied, as well as to capture the relevant aspects of the discrete air/water distribution (i.e., represent air channels at the centimeter or smaller scale). This will, in general, require a level of site data that is not available and numerical models that require many millions of computational elements. As a consequence, at least for the foreseeable future, numerical modeling of the air sparging process will continue to play a vital role as a conceptual tool with limited predictive capability at sites.

Air↗