Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “The Right to Reproduce”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Reproduction of excursive tooth contact in an articulator with computerized axiography data.

PURPOSE: This study assessed the reproduction of excursive tooth contacts with a SAM2 "P" articulator set up with the aid of computerized axiography. MATERIAL AND METHODS: Articulator excursive tooth contacts were compared with intraoral excursive contacts identified with occlusogram wax. The maxillary casts were mounted with a kinematic face-bow, and the mandibular cast was oriented to the intercuspal position. The articulator was set using information obtained from computerized axiography. Protrusion and laterotrusion to the left and right sides were examined. The first 4 mm of excursive tooth contacts in the occlusogram were compared with the 4 mm of excursive tooth contacts in the articulator. RESULTS: The articulator reproduced 82% of the teeth with protrusive tooth contacts and 90% of the teeth with laterotrusive tooth contacts. The exact locations of excursive tooth contacts were reproduced in 66% of protrusive contacts and 81% of laterotrusive contacts. The articulator also created additional eccentric dental contacts that were not originally present in the occlusogram. Twenty percent of the subjects showed these additional contacts during protrusion; in lateral movement of the articulator these additional contacts were present in 27% to the left side and 20% to the right. Clinically, these findings suggest that there are limits to the ability of the articulator to reproduce excursive tooth contacts. These limitations should be kept in mind when an articulator is used for diagnostic and restorative dental procedures.

Adolescent↗

Regional right ventricular dysfunction detected by echocardiography in acute pulmonary embolism.

This study analyzed the regional pattern of right ventricular (RV) dysfunction on transthoracic echocardiograms in patients with and without acute pulmonary embolism. Quantitative (centerline) and qualitative (wall motion score) analyses of segmental RV free wall motion were performed on a "training" cohort of 41 patients (group 1), including 14 patients with acute pulmonary embolism, 9 patients with primary pulmonary hypertension, and 18 normal subjects. Patients with acute pulmonary embolism had a distinct regional pattern of RV dysfunction, with akinesia of the mid-free wall (centerline excursion: -0.2 +/- 0.8 mm, p = 0.0001 vs normal) but normal motion at the apex (centerline excursion: 5.7 +/- 0.8 mm, p = NS vs normal). In contrast, patients with primary pulmonary hypertension had abnormal wall motion in all regions (p <0.03 vs normal). This echocardiographic finding of normal wall motion at the apex and abnormal wall motion in the mid-free wall in acute pulmonary embolism was then tested in a "validation" cohort of 85 patients (group 2), consisting of hospitalized patients with RV dysfunction from any cause, including 13 patients with acute pulmonary embolism. The finding had a 77% sensitivity and a 94% specificity for the diagnosis of acute pulmonary embolism, with a positive predictive value of 71% and a negative predictive value of 96%. Thus, a distinct echocardiographic pattern of regional RV dysfunction, in which the apex is spared occurs in acute pulmonary embolism. This finding should raise the level of clinical suspicion for the diagnosis of acute pulmonary embolism.

Acute Disease↗

Right ventricular end-diastolic volume as a measure of preload.

Right ventricular (RV) end-diastolic volume index (RVEDVI) measured by a modified thermodilution pulmonary artery catheter has been proposed as an improved measure of cardiac preload, compared with pulmonary capillary wedge pressure (PCWP). This study compared the correlation of RVEDVI and PCWP with cardiac index (CI) to determine which parameter better reflected ventricular preload. Modified thermodilution catheters were placed in 38 critically ill patients. Hemodynamic parameters were recorded in these patients at 2- to 4-hour intervals for 1 to 7 days. Complete data sets (1,008) were obtained. Regression analysis was performed comparing PCWP, RVEDVI, RV ejection fraction (RVEF) to CI in the entire group and in individual patients. Because mathematical coupling may exist between RVEDVI and CI, the correlation between these variables was corrected for mathematical coupling using the method described by Stratton. Simple regression analysis of data from all patients, uncorrected for mathematical coupling, yielded a significant correlation between CI and RVEDVI (r = 0.60, p < 0.0001), RVEF (r = 0.37, p < 0.0001), and PCWP (r = 0.01, p < 0.001). Correction for mathematical coupling between RVEDVI and CI resulted in a minor changes of the correlation coefficient to 0.56. In individual patients, a significant, uncorrected correlation (p < 0.05) was found between RVEDVI and CI in 27 of the 38 patients, whereas 11 patients had a significant correlation between PCWP and CI. RVEDVI correlated more closely with CI than did PCWP, even after correlation for mathematical coupling. In both the group as a whole and in individual patients, RVEDVI was a better indicator of cardiac preload.

Adolescent↗

Utility and reproducibility of semiquantitative analysis of sestamibi breast images.

UNLABELLED: Technetium-99m-sestamibi scintimammography has been shown to be a useful diagnostic test in the detection of breast cancer. The purpose of this study was two-fold to: (a) evaluate semiquantitative indices of tracer uptake in lesions and determine if they are helpful in distinguishing benign from malignant breast lesions; and (b) test the reproducibility of these measures of sestamibi uptake in breast images. METHODS: Prone lateral planar imaging was performed on 27 patients after intravenous injection of 20-30 mCi 99mTc-sestamibi. Data were analyzed by creating three regions of interest (ROIs) over designated areas: lesion, normal breast and right chest wall. Lesion-to-normal (L:N) and lesion-to-chest wall (L:CW) ratios were calculated for each patient. Reproducibility was assessed by having two independent observers draw ROIs (interobserver) and one observer draw two independent sets of ROIs (intraobserver). RESULTS: L:N and L:CW ratios were significantly different for malignant versus benign lesions (p < 0.001 for both ratios). Intraobserver and interobserver reproducibility showed good correlation with r = 0.98 (L:CW ratio). CONCLUSION: Semiquantitative analysis of sestamibi breast imaging results in reproducible uptake ratios that may be helpful in objectively interpreting imaging results.

Adult↗

Best reproducibility of the ankle-arm index was calculated using Doppler and dividing highest ankle pressure by highest arm pressure.

BACKGROUND AND OBJECTIVE: To investigate which method of ankle-arm index (AAI) measurement in terms of selected arteries and blood pressure devices yields the highest reproducibility. STUDY DESIGN AND SETTING: In this cross-sectional study, duplicate AAI measurements were obtained at the right and left side in 320 postmenopausal women. Analyses were done as proposed by Bland and Altman and intraclass correlation coefficients were calculated. RESULTS: The mean and standard deviation (SD) of the first and second systolic blood pressure (SBP) measurement separately did not differ from the mean and SD of the duplicate SBP measurements averaged. Coefficients of repeatability and intraclass correlation coefficients were comparable when the ankle SBP was measured in the posterior tibial artery or dorsalis pedis artery. Coefficients of repeatability as well as the intraclass correlation were better when the SBP in the brachial artery was measured with Doppler than with Dinamap. CONCLUSIONS: To achieve the best reproducibility and smallest systematic difference in the AAI, single SBP measurements should be obtained by Doppler in the brachial artery, posterior tibial artery and dorsalis pedis artery. The AAI should be calculated for each foot separately by dividing the highest ankle SBP by the highest arm SBP.

Aged↗

Continuous haemodynamic monitoring during exercise in patients with pulmonary hypertension.

BACKGROUND: Right heart haemodynamic parameters can be recorded continuously with the help of an implanted haemodynamic monitor. Aim of the study was to assess the haemodynamic response with and without inhalation of iloprost during cardiopulmonary exercise testing (CPET) in patients with pulmonary hypertension. MATERIALS AND METHODS: Five female patients with documented pulmonary hypertension (mean +/- S.D. age 47 +/- 16 years, 4 arterial, 1 venous) previously implanted with a haemodynamic monitor underwent an incremental exercise test on 2 separate days. The tests were performed before and immediately after inhalation of a single dose of iloprost (17 microg). Parameters recorded by the device were right ventricular (RV)-afterload (RV systolic pressure, RVSP), RV-preload (RV diastolic pressure, RVDP), estimated pulmonary artery diastolic pressure (ePAD), heart rate (HR) and maximum positive rate of RV pressure development (RVdP/dt) (reflecting the dynamic and inotropic state of the RV). RESULTS: After inhalation of iloprost, RV systolic pressure was always reduced at rest. It was followed by an increase with higher workloads without any difference at VO(2peak). The time course of RV systolic pressure was not linear with a flattening at higher workload during the test. This behaviour was found irrespective of iloprost treatment. The remaining determinants of RV performance showed no relevant differences and a linear behaviour during the exercise test. CONCLUSIONS: Inhalation of aerosolised iloprost resulted in a reduction in right ventricular pressure at rest but not at maximal workload. The implantable haemodynamic monitor (IHM) may be useful for the evaluation of RV haemodynamics during exercise and in assessing treatment efficacy.

Adult↗

Measuring movement irregularity in the upper motor neurone syndrome using normalised average rectified jerk.

Movement irregularity is a feature of the upper motor neurone (UMN) syndrome which is difficult to measure. Average rectified jerk (ARJ) has been proposed as a measure of this movement irregularity, but ARJ depends upon the duration of movement. Since movements may be slower in UMN patients, duration dependence compromises ARJ as a measure of irregularity. A normalisation technique is proposed that generates a measure of movement irregularity which is independent of movement duration: normalised average rectified jerk (NARJ). This paper presents a validation of NARJ in the UMN syndrome. Nine control subjects, nine left hemiparetic stroke patients and nine right hemiparetic stroke patients were studied. Test movements comprised elbow extension/flexion in the horizontal plane; these were recorded with an electro-goniometer and accelerometer. The effectiveness of the normalisation technique has been demonstrated using trajectories of various durations; some of these were artificially generated from participants' trajectories, in order to preserve the movement profile. The variability of NARJ and ARJ have been compared in a sample of control subjects. NARJ has been criterion validated by correlation with expert subjective rating of irregularity in a heterogeneous set of trajectories. Construct validity has been tested by discrimination between movements of control subjects, left hemiparetic stroke patients and right hemiparetic stroke patients. When comparing trajectories of identical profile but two-fold difference in movement duration, NARJ differed only 2.6% whereas ARJ differed 706%. NARJ was less reproducible in healthy participants than ARJ: median non-parametric coefficients of variation for repeated movements were 55% and 41%, respectively. Spearman rank correlation coefficient for NARJ and expert rating was 0.92 (p<0.01). NARJ measurements on right hemiparetic patients differ significantly from those made on the control group (p<0.02); corresponding ARJ measurements do not attain statistical significance. NARJ is a valid measure of movement irregularity in the UMN syndrome.

Adult↗

Vibratory and tactile sense of the fingers after working with sanders.

Twenty-four volunteers worked four times in a laboratory under realistic conditions for 80 min with a relatively intensely vibrating plane-sander and a less intensely vibrating band-sander (each sander twice). Immediately before and after exposure, the left and right third finger was measured for vibratory sense with a 100 Hz rod-vibrameter and for width- and depth-sense by means of an apparatus modified after Carlson. The reproducibility of the parameters was poor: coefficients of intra-individual variation were 20 to 60%. After using the plane-sander the threshold of the width-sense in the right hand increased relative to the effect of the band-sander by 17% of the pre-exposure value; in the left hand no increase was found. The thresholds of the depth-sense and vibratory sense showed no change. The study suggests that brief vibration exposure below the ISO-guideline may cause some reduction of sensibility. One should be cautious in applying these tests. An exposure-free interval of at least several hours is recommended when studying chronic effects of vibration exposure.

Adult↗

Right heart function in systemic lupus erythematosus: insights from myocardial Doppler tissue imaging.

The purpose of this study was to use Doppler tissue imaging to evaluate heart function and to investigate the correlation between Doppler imaging and pulmonary artery systolic pressure (PASP) and right ventricular (RV) ejection fraction (EF) in patients with systemic lupus erythematosus (SLE). Standard echocardiography and 2-dimensional and color Doppler imaging were used to assess cardiac function in patients given the diagnosis of SLE (n = 40) and healthy control subjects (n = 45). Half of the patients with SLE also presented with pulmonary hypertension (PH). Significant differences in PASP and RV EF (RVEF) were found between the control and SLE groups. The peak systolic velocity of tricuspid annulus was significantly lower in patients with SLE than in the control group. The calculated myocardial performance index of the RV, septum, and left ventricular lateral wall were significantly higher in patients with SLE than in the control group. Bivariate correlation analysis revealed a significant correlation among PASP, RVEF, and systolic tricuspid annular velocity. There was a significant correlation between each of these 3 parameters and the 6-minute walk distance in patients with SLE. Patients with SLE and PH had a significantly shorter 6-minute walk distance than patients with SLE without PH. Furthermore, in patients with SLE and PH, RVEF and systolic tricuspid annular velocity were lower than in the control subjects and patients with SLE without PH. Patients with SLE and PH had a longer isovolumic relaxation time and a higher myocardial performance index of RV than those without PH. Finally, by simple linear regression analysis, we found a significant positive relation between RVEF and systolic tricuspid annular velocity, but a negative relationship between PASP and systolic tricuspid annular velocity. These findings demonstrate that in patients with SLE, systolic tricuspid annular velocity determined by echocardiography and Doppler imaging can be used to assess RV function and PASP. Furthermore, systolic tricuspid annular velocity reflects exercise tolerance in patients with SLE and the length of the isovolumic relaxation time represents the progression of PH.

Adult↗

On-line evaluation of systolic performance by densitometry in digital left ventriculography.

The angiocardiographic evaluation of left ventricular end-diastolic (LVEDV) and end-systolic (LVESV) volumes and ejection fraction (EF) is routinely performed by the area-length method (ALM) but may lead to erroneous results. Digital imaging in real time allows densitometric procedures of determining left ventricular (LV) performance to be applied alternatively. In this study, we present densitometric algorithms for the analysis of LVEDV, LVESV, and EF from digital image data, establish accuracy and reproducibility, and determine value and limitations in comparison with ALM in single-plane 30 degrees right anterior oblique (RAO) projection. A linear relationship between iodine depth and measured densities is mainly burdened with scatter radiation and beam hardening which reduce primary radiation and suppress iodine depth. However, facilities such as deconvolution and correction algorithms are capable of reducing these sources of error. In the present study, computer-analyzed contrast images of iodine-filled wedges and spheres showed a near-linear relationship between iodine depth between 50-100 mg/cm2 and measured densities. Contrast images of heart casts and LV angio-grams of 54 patients were obtained with a digital image acquisition and processing system, and evaluated by two independent observers. The phantom study resulted in significantly (p < or = 0.01) better densitometric standard errors of estimate for volumes [3.3 ml densitometry (DENS) vs. 8.9 ml (ALM)] and simulated EF [4.3% (DENS) vs. 7.8% (ALM)] than ALM. The standard error of estimate for the comparison between both methods was 8.4 ml for volumes and 7.5% for EF. Densitometric volumes tended to underestimate volumes calculated by ALM. The angiographic study of patients demonstrated significant correlations between both methods (LVEDV r = 0.78, LVESV r = 0.83, total volumes: r = 0.89; EF r = 0.88). The standard errors of estimate can be ascribed to systematic, method-related errors of both DENS and ALM (LVEDV +/- 28.9 ml, LVESV +/- 23.4 ml, total volumes (EDV and ESV) +/- 27.1 ml; EF +/- 8.1%). The intra- and interobserver variability, respectively, exhibited significantly smaller (p < or = 0.01 and p < or = 0.05, respectively) standard errors of estimate for densitometric EF [4.6% (DENS) vs. 8.5% (ALM) and 7.1% (DENS) vs. 10.3% (ALM), respectively]. Inclined but not significant differences were found for LVEDV and LVESV. In conclusion, the data presented indicate that the calculation of LV volumes and EF in digital left ventriculography may be performed accurately by densitometric calculation in single-plane 30 degrees RAO projection. Minor underestimations in densitometric volume determination may be anticipated in the evaluation of LV geometry.

Adult↗

A new irradiation system for lung cancer combining linear accelerator, computed tomography, patient self-breath-holding, and patient-directed beam-control without respiratory monitoring devices.

PURPOSE: To introduce and assess a new irradiation technique for lung cancer that utilizes a linear accelerator and computed tomography (CT) scanner combination, along with a novel switching mechanism, which enables patients to synchronize the duration of irradiation with self-breath-holding without respiratory monitoring devices. MATERIALS AND METHODS: A newly developed treatment unit, a linear accelerator combined with a CT scanner (CT-linac), was used for irradiation. A novel switching mechanism, connected directly to the console of the linear accelerator, enabled the patient to control the radiation beam to correspond with the duration of self-breath-holding during a session determined by a radiation technologist. Twenty patients with lung cancer were enrolled in this study. All patients were instructed in the technique of breath-holding during the inspiration phase using visualization of respiratory motion through fluoroscopy as a teaching aid. CT scans under patients' self-breath-holding were repeated three times, and differences in tumor position on CT images were measured. The reproducibility of tumor position was visually evaluated on electronic portal images (EPI). RESULTS: Mean maximum differences in tumor position under patients' self-breath-holding were 2.2 mm in the cranial-caudal direction, 1.4 mm in the anterior-posterior direction, and 1.3 mm in the right-left direction. Switching of the radiation beam was delayed less than 0.1 s behind patient switching. EPIs were used to determine that reproducibility of tumor position was satisfactorily accurate. CONCLUSIONS: The reproducibility of tumor position, during patient self-breath-holding synchronized with patient-initiated radiation and without a respiratory monitoring device, was sufficiently accurate. This novel irradiation technique for lung tumors using a combination CT-linac offers reduced PTV, sufficient reproducibility, and decreased duration of treatment.

Aged↗

Preload-adjusted right ventricular maximal power: concept and validation.

Right ventricular (RV) maximal power (PWR(mx)) is dependent on preload. The objective of this study was to test our hypothesis that the PWR(mx) versus end-diastolic volume (EDV) relationship, analogous to the load-independent stroke work (SW) versus EDV relationship (preload-recruitable SW, PRSW), is linear, with the PWR x-axis intercept (V(0PWR)) corresponding to the PRSW intercept (V(0SW)). If our hypothesis is correct, the preload sensitivity of PWR(mx) could be eliminated by adjusting for EDV and V(0PWR). Ten dogs were instrumented with a pulmonary flow probe, micromanometers, and RV conductance catheter. Data were obtained during bicaval occlusions under various conditions and fitted to PWR(mx) = a.(EDV - V(0PWR))(beta), where a is the slope of the relationship. The PWR(mx) versus EDV relationship did not deviate from linearity (beta = 1.09, P = not significant vs. 1), and V(0PWR) correlated with V(0SW) (r = 0.93, P <0.0001). V(0PRW) was related to steady-state EDV and left ventricular end-diastolic pressure, allowing for estimation of V(0PWR) (V(0Est)) and single-beat PWR(mx) preload adjustment. Dividing PWR(mx) by the difference of EDV and V(0PWR) (PAMP(V0PWR)) eliminated preload dependency down to 50% of the baseline EDV. PWR(mx) adjustment using V(0Est) (PAMP(V0Est)) showed similar preload independency. Enhancing contractility increased PAMP(V0PWR) and PAMP(V0Est) from 176 +/- 52 to 394 +/- 205 W/ml x 10(4) and 145 +/- 51 to 404 +/- 261 W/ml x 10(4), respectively, accompanied by an increase of PRSW from 13.0 +/- 4.5 to 29.7 +/- 16.4 mmHg (all P <0.01). PAMP(V0PWR) and PAMP(V0Est) correlated with PRSW (r = 0.85; r = 0.77; both P <0.001). Numerical modeling confirmed the accuracy of our experimental data. Thus preload adjustment of PWR(mx) should consider a linear PWR(mx) versus EDV relationship with distinct V(0PWR). PAMP(V0PWR) is a preload-independent estimate of RV contractility that may eventually be determined noninvasively.

Animals↗

Reproducibility test on a children's insole for measuring the dynamic plantar pressure distribution.

INTRODUCTION:: This study aimed to establish the reproducibility of a insole measuring system specifically designed for use inside children's shoes. It is important to carry out such an investigation before any measurements are taken in order to ensure that any errors associated with the system are known and quantified. The children's insole had 84 pressure sensors, compared to the adult insoles, with 99 pressure sensors. The sensor technology was essentially the same as used in the adult Pedar system, and incorporated capacitance-based pressure transducers. MATERIALS AND METHOD:: An eight year old boy, height 123 cm, weight 29 kg, was used in the study. Dynamic tests were carried out with the Pedar insole measuring system. The subject walked on a treadmill, at a speed comfortable for him (3 km/h), with the insoles placed between the foot and the shoe. No fixation of the insole to the shoe was used. Seven runs were completed, each with four tests recorded of more than twenty steps. In between each run the insoles were completely removed from the shoe and then replaced. A zero measurement was also taken before the continuation of the next run. Before analysis of the data, twenty steps were selected. The first two steps in each sequence were ignored and the following twenty steps were used in the analysis, ten each for the left and the right foot. Any additional steps recorded were also ignored. The average force for the test data file was initially noted, together with the local pressure for each of the forefoot, midfoot, heel and toe regions, for both the left and the right foot, separately. RESULTS:: The within test data and in-between test data when walking on a treadmill at constant speed was found to be reproducible (F(0.01)) for 6 out of 7 tests for the left and the right foot. The standard deviation of the average force for the left and the right foot was 3%. The 95% confidence intervals for the mean of the peak pressure in the total object was within 6% for the treadmill and free walking data. There was no significant difference between these data. The 95% confidence intervals for the mean of the peak pressure under the big toe was 9% for the treadmill data and 16% for the free walking data. CONCLUSIONS:: These results, together with other published data (McPoil et al. 1995) show that the pedar children's insole system provides accurate and reproducible measurements of the dynamic plantar pressure distribution. The clinician can therefore use this system with confidence as a therapeutic or rehabilitative tool.

Journal Article↗

[Is measurement of body temperature by infrared tympanic thermometry reproducible?].

OBJECTIVE: To assess the reliability of body temperature estimated by infrared tympanic thermometry. STUDY DESIGN: Prospective study. PATIENTS AND METHODS: 71 patients in a neurosurgical intensive care unit. 393 triplets of measurements were performed: right ear, left ear and right ear again. RESULTS: Limits of agreements are [-1, +1 degree C] between both ears, and [-0.6, +0.7 degree C] for two consecutive measurements in the right ear. The Bland and Altman diagram show that most of the points responsible for the lack of accuracy are between 36 and 37 degrees C. CONCLUSION: These values give an estimation of the technique's accuracy. In our point of view, such a reproducibility is adequate for daily clinical practice. The accuracy of infrared tympanic thermometry with the First Temp Genius seems reasonable for the clinical practice when the temperature is over 37 degrees C.

Body Temperature↗

Dimensions of cardiac chambers and great vessels by cross-sectional echocardiography in infants and children.

A total of 120 healthy infants, children, and teenagers were examined by cross-sectional echocardiography. Right and left atrial and ventricular dimensions and areas were measured in the parasternal, apical, and subcostal views. Dimensions of the inferior caval vein, the pulmonary artery and the aorta were obtained in the parasternal, suprasternal, and subcostal views. Reproducibility was studied in separate material consisting of 19 children with various forms of congenital heart disease examined consecutively by two different observers. Interobserver reproducibility was expressed as the 95% tolerance limit for the difference between two measurements. Good correlation with body surface area was demonstrated for all measurements, and the regression equations for the normal values of the parameters studied are given. Interobserver reproducibility was fairly good for measurements in the parasternal views, but moderate or low for measurements in the apical and the subcostal four-chamber views. Measurements in cross-sectional echocardiography are clinically useful, especially in the study of the right-sided cardiac structures that are difficult to evaluate with M-mode echocardiography, but the problems of reproducibility have to be taken into account.

Adolescent↗

Left and right ventricular diastolic dysfunction as predictors of difficult separation from cardiopulmonary bypass.

PURPOSE: As the evaluation of diastolic function can be complex in the setting of a busy cardiac operating room, its assessment may benefit from an algorithmic approach using transesophageal echocardiography. We developed a diagnostic algorithm which was then applied in a series of cardiac surgery patients to determine whether moderate to severe left ventricular diastolic dysfunction (LVDD) and right ventricular diastolic dysfunction (RVDD) can predict difficult separation from cardiopulmonary bypass (DSB). METHODS: An algorithm using pulsed-wave Doppler interrogation of the mitral and tricuspid valve, the pulmonary and hepatic venous flow, and tissue Doppler interrogation of the mitral and tricuspid annulus was developed. The study was divided in two phases involving two groups of patients undergoing cardiac surgery. In phase I, echocardiographic evaluations of patients (n = 74) were used to test the reproducibility of the algorithm and to evaluate inter-observer variability using Cohen's kappa values which were calculated in three specific periods. In phase II, the algorithm was applied to a second group of patients (validation group, n = 179) to explore its prognostic significance. The primary end-point in phase II was DSB. RESULTS: In phase I, the kappa coefficients for LVDD and RVDD algorithms were 0.77 and 0.82, respectively. In phase II, moderate or severe degrees of LVDD were observed in 29 patients (16%) and moderate to severe RVDD was observed in 18 patients (10%) before cardiac surgery. Both moderate and severe LVDD (P = 0.017) and RVDD (P = 0.049) before surgery were observed more frequently in patients with DSB. CONCLUSION: Moderate and severe LVDD and RVDD can be identified with very good reproducibility, and both degrees of diastolic dysfunction are associated with DSB.

Aged↗

Echocardiographic Assessment of Right Ventricular Volume and Function.

Echocardiographic evaluation of right ventricular volume and function has become a subject of growing interest with the increasing awareness of the important role of the right ventricle in the entire circulation. However, the anatomically complex and load-dependent shaped right ventricle shape is difficult to describe by a simple geometric figure and its volume and function are, therefore, difficult to assess in a simple manner. A number of echocardiographic methods for evaluating right ventricular volume and function have emerged; to date, however, their quantification remains a clinical challenge. The major goal is to develop a reproducible method that will allow for quantitative comparisons between patients or serially within a given patient. This discussion examines the available methods with specific attention to their reliability and limitations. Visual inspection or measurement of single plane indices is limited by their lack of standardization and failure to describe the entire right ventricle. Simpson's rule requires computer calculations and assumes an elliptic symmetry present in the left, but not the right ventricle. Application of the area-length method to the subcostal outflow tract and apical four-chamber views is a particularly practical current approach. Three-dimensional echo reconstruction, which eliminates the need for geometric assumptions and individual standardized views, although only in its infancy, promises to be the most accurate method for right ventricular volume calculation and in the future should emerge as the standard for research and many clinical applications.

Journal Article↗